Introduction
The water brewing temperature (Tb) can become much more consistent in the
Gaggia Espresso machine with the PID temperature controller modification. The
boiler temperature can be stabilized by a PID temperature controller in less than
10 minutes; however, the water brewing temperature takes longer time to
stabilize. The PID temperature setting (set value or SV) for the boiler should be
set higher than the optimal water brewing temperature to compensate the heat
loss of the grouphead. This study is to find the correlation between the PID
temperature setting and water brew temperature. It will help the user to make for
consistent espresso.
1
http://www.biggreenegg.com/boilingPoint.htm#pressure. It was also verified by a
NIST traceable thermometer at 37.0 C. The maximum error of this thermometer
is <0.2 C over the 0 to 110 C range.
Controller calibration
The set up for calibrating the controllers is shown in picture 1. A stainless steel
pitcher filled with cooking oil was placed on a hot plate with magnetic stirrer. The
hot plate was controlled by a PID temperature control system to make the
temperature stable. The mercury thermometer was inserted to the oil bath at its
immersion line. The temperature slowly changed from 80 C to 110 C at rate of
<0.5C/min. The controller reading was compared with the mercury thermometer,
with the error adjusted by the meter’s offset. After calibration, the controller had <
0.2 C errors when compared with mercury thermometer.
Thermofilter calibration
Since the Thermofilter was not used for over 100C and the oil bath might
damage the glue used on it, it was calibrated in a Dewar thermos as shown in
Picture 2. The thermos was also used because it took a long time to equilibrate
the temperature, due to the large thermo mass attached and limit heat circulation
(this is not the case when measuring the brew water because the water moves
very fast). Boiling water was poured into the Dewar that contained the
Thermofilter and a calibrated RTD sensor. After 20 minutes of equilibration (cap
sealed), the reading was compared with the calibrated thermometer. After
calibration, the error of the Thermofilter was <0.3C.
2
Picture 2. Thermos used for calibrating Thermofilter
After the experiment, we re-calibrated all the controllers and the Thermofilter to
make sure no instruments drifted over this period of time.
210
Water Brewing Temp (F)
205
Average
200
Peak
195
190
185
205 210 215 220 225 230
Set Temperature (F)
3
102
100
96
94 Average
92 Peak
90
88
86
84
98 100 102 104 106 108 110
Set Temperature (C)
Figure 1 shows the relationship between Tb and SV. All data was taken 30
minutes after the SV is changed and after several shots to let system stabilized.
The brew water temperature is not constant during the shot. Their waveform is
shown in Fig. 2. The peak value can be 10 C (18F) higher than the temperature
at the end of shot. That is due to the small size of the boiler and the material
used for the boiler (Aluminum). Because the waveform changes at different SV,
we think using the average temperature instead of peak will be more consistent
and closer to the real espresso making situation.
0.98
0.96
0.94 103
99
Temp x100 (C)
0.92 100
102
0.9
106
0.88 109
107
0.86
101
0.84
0.82
0.8
1
Time (4s/div)
4
Figure 2. The waveform for of the temperature change at different SV. Each trace
represents a 25 seconds double shot. The SV value (in Celsius) is listed on the
right side of the graph. Only one group of tests used in Fig. 1 is presented in this
figure.
SV=216 F
205
200
Temp (F)
195
Avg
Max
190
185
180
0 10 20 30 40 50 60
Time (min)
SV=102 C
96
94
92
Temp (C)
90 Avg
88 Max
86
84
82
0 10 20 30 40 50 60
Time (min)
Figure 3. Brew water temperature changes as the machine warms up. Each data
point represents a 25 second double shot. Both the peak temperature (Max) and
the average temperature during the brewing are plotted. Top, plot in degrees
Fahrenheit. Bottom, Plot in degrees Celsius.
5
Figures 3 shows the water brewing temperature (Tb) change measured by the
Scace Thermofilter versus time. The timers started when the machine was
powered up from room temperature. Each data point represents a 25 second
double shot shown Figure 4. Both the average temperature and the peak
temperature are presented. The data is collected at minimum of 4 minutes
interval.
From these figures we can see that when the machine started from cold, the Tb
can be 9 degree C lower than when it is warmed up, even if the boiler
temperature was stabilized. Therefore, it is important to let the machines warm
up before brewing starts. After the machine was powered up for 20 minutes, the
Tb stabilized to +/- 2 degree C.
SV=102 C
0.95
49
0.9
42
34
Temp (x100 C)
30
0.85
26
22
0.8 18
14
11
0.75 7
0.7
1
Time (4 s/div)
Figure 4. The waveforms used to generate the data points used in Fig. 3. The
legend on the right side is time in minutes. It represents the time since the
machine powered up.
6
SV=216 F
210
Brew Water Temp (F)
205
200
Average
195
Peak
190
185
180
0 5 10 15 20
Time Interval (min)
SV=102 C
98
Brew Water Temp (C)
96
94
92
Average
90
Peak
88
86
84
82
0 2 4 6 8 10 12 14 16
Time Interval (min)
Figure 5. Brew water temperature of the second shot as a time function from the
first shot. Top, plot in degrees Fahrenheit. Bottom, Plot in degrees Celsius.
Figure 5 shows the temperature of the second shot at different time interval from
the first shot. In this study, we set the SV at 216 F (102 C) and let the machine
stabilized for 1 hour before start the testing. Then, we made two consequential
shots with different time interval between the shots. The first shot was stabilized
for at least 10 minutes before the second shot. We measured brew water
temperature of the second shot only. The time zero is when the first shot started.
This study shown that although the controller can stabilized the temperature near
its sensor location in less than 2 minutes (data not shown), the brew water
temperature will take at least 4 minutes to recover to ± 2 C of its steady state. 7
to 8 minutes is needed for temperature to be in the ± 1C from the steady state.
7
Conclusion
When making a double shot (60 ml), the brew water temperature of Gaggia
Coffee deluxe can drop 10 C (18 F) at the end of the shot. However the
temperature change profile is reproducible and predictable. When correctly
operated, the Gaggia can produce a very reproducible shot. The brew
temperature will take at least 20 minutes to stabilize after start from room
temperature. The time needed between the shots should be at least 4 minutes or
longer. The optimal PID setting temperature should be between 210 to 225 F (99
to 107 C)
Acknowledgement
The author would like to thank Praveen Nadaraju for many helpful suggestions
on this study.