WALL-TOP UNITS

WALL-TOP assembly
UNITS Construction - Keyter WALL-TOP units
MIXING AND
COMPACT EQUIPMENT OUTDOOR UNIT
RECOVERY
CHAMBER
INDOOR UNIT
air-to-air, wall mounted

12 - 46 kW
Low-speed axial Attachment
motor fans
NEW panel
AIR
13 - 47 kW

Electric control and


power panel Dynamic
recovery coil
RETURN
EXTRACTION AIR
AIR

Ventilation chamber
Scroll compressor with EC radial or
acoustically insulated centrifugal fan

AIR
RETURN
Adaptation and Versatility Energy efficiency
•The wall-top units have a new compact, lightweight • High partial and full load efficiency, reducing
design and are easy to mount on the wall operating costs
•Many configuration options thanks to OPTIONS • Optimised dynamic extraction air heat recovery
and a wide variety of ASSEMBLIES for correct air systems via additional exchange coils that increase
distribution subcooling, resulting in a substantial improvement
• Maximum accessibility and easy maintenance via in the equipment's efficiency
removable panels • Design with mixing section, Free-cooling and an
•Adaptation to air conditioning needs as per RITE increase in subcooling Types of assembly - Keyter WALL-TOP units
• Electronic fans and electronic expansion valve
available for minimum power consumption
Wall-top units with indoor
• Compliance with ErP 2018 axial or centrifugal fans for air
ducting

Wall-top units with


indoor axial fans for free
discharging
Low noise level
Environment
• Compressors in insulated, closed compartment
available with acoustic isolation jacket
• Optimised design for reduced load of refrigerant
• Low revolution axial condensation fans R-410A (ODP 0, GWP 2088)

Applications
Education
Easy control

• Electronic regulation and CAREL supervision for


simple use and high performance
• Wide variety of communication protocols
(Modbus, BACnet and LonWorks) Industry Supermarkets Entertainment

and other applications, please consult us

44 KEYTER WALL-TOP UNITS KEYTER WALL-TOP UNITS 45


WALL-TOP UNITS WALL-TOP UNITS
Technical data 12 - 46 kW
Dimensions
KCH model 2013 2022 4045 2013 2022 4045 Dimensions (equipment with free-cooling or recovery):
EURO COMFORTER
Cooling only version (R)
series 2
Cooling power (1) kW 12.5 21.5 46.9 12.2 21.1 45.6
TR 3.5 6 13 3.5 6 13
kBTU/hr 42.6 73.4 160.0 41.6 72.0 155.6
Absorbed power (2) kW 4.5 7.6 15.2 4.5 7.7 14.8
Cooling
EER (3) W/W 2.8 2.8 3.1 2.7 2.7 3.1
BTU/(Wxhr) 9.4 9.6 10.5 9.3 9.4 10.5
H
SEER (4) 3.3 3.3 3.5 2.6 2.7 2.9
ŋs,c (5) 130% 129% 139% 100% 104% 112%
Heat pump version (I)
Cooling power (1) kW 12.0 20.8 44.8 12.0 20.8 44.8
Absorbed power (2) kW 4.7 7.8 15.6 4.7 7.9 15.2
L W
Cooling
EER (3) W/W 2.7 2.8 3.1 2.6 2.6 2.9
mode
SEER (4) 3.2 3.2 3.3 2.5 2.6 2.8
ŋs,c (5) 124% 123% 129% 97% 100% 111%
Heating power (6) kW 13.1 23.1 46.8 13.1 23.1 46.8
Absorbed power (2) kW 4.7 8.2 14.2 4.7 8.3 13.8
Heating
mode
COP (3) W/W 2.9 2.9 3.6 2.8 2.8 3.4 series 4
SCOP average climate (4) 3.0 3.0 3.1 2.4 2.5 2.8
ŋs,h average climate (5) 119% 117% 121% 94% 97% 107%
Technical characteristics
Electrical supply 400 V/III/50 HZ with neutral 400 V/III/50 HZ with neutral
Refrigerant fluid/GWP kg CO2 R410A/2088 R410A/2088
Cooling Type of compressor Hermetic scroll Hermetic scroll
circuit No. circuits/No. compressors 1/1 1/1 1/1 1/1 1/1 1/1 H
No. power stages 1 1 1 1 1 1
Induction airflow m3/h 2100 4000 8000 2100 4000 8000
Nominal available pressure Pa 50 62 75 50 62 75
Indoor fan No. x Type of fan 1 x EC plug fan 1 x Centrifugal
L W
Motor unit power kW 2.68 2.68 2.68 0.25 0.75 1.1
Absorbed power kW 0.32 0.39 0.95 0.18 0.49 0.69
Outdoor airflow m3/h 4200 8400 18200 4200 8400 18200
Outdoor fan
No. x Type of fan N x (mm) 2 x Axial 450 EC 2 x Axial 450 AC 2 x Axial 630 AC 2 x Axial 450 EC 2 x Axial 450 AC 2 x Axial 630 AC
Equipment sound pressure of Lp10 (7) dB(A) 32 35 42 32 35 42 Standard equipment dimensions (mm)

Weight kg 292 348 461 294 350 465 Series 2 Series 4


L 1833 2285
W 1339 2290
(1) Nominal cooling power for an indoor air temp. of 27ºC/50% RH and outdoor air temp. of 35ºC.
H 1216 1220
(2) Total power absorbed by compressors, outdoor fans and induction fan.
(3) EER and COP calculated based on standard EN 14511-2013.
(4) Seasonal Energy Efficiency Ratio (SEER) for cooling factor and seasonal coefficient of performance (SCOP) for heating, calculated based on standard EN 14825:2013.
(5) Seasonal Energy Efficiency Ratio for cooling (ŋs,c) and heating (ŋs,h) of spaces, in line with Ecodesign Regulation EU 2016/2281.
(6) Nominal heating power for an indoor air temp. of 20ºC and outdoor air temp. of 7ºC DB/6ºC WB.
(7) Sound pressure level in dB(A) measured in a free field at 10 m from the source, directivity 2 and 1.5 m from the floor.

Electronic control: Options:


Keyter series production WALL-TOP equipment includes the CLIMANAGER programmable electronic control, specifically developed for the management • Dynamic recovery • Ambient temperature sensor
of air-to-air equipment, with a TH-Tune user terminal in the standard version and the pGD1 user and maintenance terminal in equipment with free- • Electronic expansion valve • Anti-corrosion treatments of the coils
cooling or recovery. • Radial induction fans with EC technology (BLUECOAST, ALUCOAST, GREYCOAST, BLYGOLD AND COPPERFIN)
• Axial fans, outdoor unit with EC technology • Forced ventilation of the electrical panel
• F filtration section • Other electrical voltages (230 V/III ph/50-60 Hz, 380 V/III ph/60 Hz,
400 V/III ph/60 Hz, 460 V/III ph/60 Hz)
• Thermal and enthalpic free-cooling
• RS485 card for communication in MODBUS protocol
• Supporting electrical resistor
• PlantVisor/Plant Watch Pro
• Hot water backup battery with 3-way valve
• BACNET/LONWORKS communication
• Dirty filter detector
• KCH equipment may be produced as a split version based on a
• Smoke detector consultation
• Ambient/duct CO2 or VOC sensor

CLIMANAGER TH-Tune controller pGD1 controller

46 KEYTER WALL-TOP UNITS KEYTER WALL-TOP UNITS 47