PRODUCED BY AN AUTODESK STUDENT VERSION

EXISTING PLOT AREA CALCULATION


GROSS PLOT AREA - 37934.42 SQ. M
OPEN SPACE(10%)- 3793.44 SQ. M
BUILT UP IN OPEN SPACES - 569 SQ. M
(15%OF THE OPEN SPACES)
AMENITIES SPACE - 5690.16 SQ. M
NET AREA = 28450.82 SQ. M (GROSS AREA - OPEN SPACES -
AMENITIES)
FSI OF THE AREA -1.1 (ACC. TO DCR)
T.D.R (TRANSFER OF DEV. RIGHTS )-1.4
ADDITIONAL FSI ON PAYMENT OF PREMIUM - 0.5
TOTAL - 3 (FSI+TDR+PREMIUM FSI)
AFTER INCLUDING FSI = 28450.8 X 3 = 85352 SQ.M
B
STAIRCASE , CORRIDOR, LIFTS, 25% TO BE DEDUCTED AND
BENEFITS FOR THE OLD PROPERTY OWNERS (30% TO BE ADDED ) Y
NET AREA = 85352 - (25% I.E 21338)
=63914 + (30% I.E 25605.6)
=89519.6 SQ.M
L
FRONT MARGIN SOME RULES AND REGULATIONS
A

PRODUCED BY AN AUTODESK STUDENT VERSION


W
PRODUCED BY AN AUTODESK STUDENT VERSION

1 HEIGHT ABOVE 18M AND UPTO 24M. 4.5M AND 6M FOR RESIDENTIAL USE
1- IN CASE OF LAYOUT OF TWO OR MORE BUILDINGS OF ANY USERS.
2 HEIGHT ABOVE 24M AND UPTO 36M 6.0 M THE DISTANCE BETWEEN TWO BUILDINGS SHALL BE THE SIDE/REAR
3 HEIGHT ABOVE 36M AND UPTO 50M 9.0 M MARGINAL DISTANCE REQUIRED FOR THE TALLER BUILDING BETWEEN THE
4
5
HEIGHT ABOVE 50M AND UPTO 70M
HEIGHT ABOVE 70M AND UPTO 100M
12.0M
14.0 M
TWO ADJOINING BUILDINGS
2- MINIMUM DIMENSIONS FOR RECREATIONAL OPEN SPACES
S
6 HEIGHT ABOVE 100M 16.0 M
THE MINIMUM DIMENSIONS OF SUCH RECREATIONAL OPEN SPACES
SHALL BE NOT LESS THAN 10M . AND IF THE AVERAGE WIDTH OF SUCH
PERMISSIBLE FSI RECREATIONAL OPEN SPACE IS LESS THAN 20M . THE LENGTH THEREOF
SN ROAD WIDTH IN M
1
2
BELOW 9.0 M
BASIC FSI
1.10
PREMIUM FSI TDR
-- --
MAX BUILTUP
1.10
SHALL NOT EXCEED 2.5 TIMES THE AVERAGE WIDTH
3- STRUCTURES PERMITTED IN OPEN SPACE
&
9.0M AND UPTO 12.0 M 1.10 0.30 0.40 1.80
3
IF REQUIRED, STRUCTURE AND USES WHICH CAN BE PERMITTED
12.0M AND UPTO 18.0M 1.10 0.50 0.65 2.25
4 18.0M AND UPTO 24.0M 1.10 0.50 0.90 2.5
WITHOUT COUNTING IN FSI IN THE RECREATIONAL OPEN SPACES SHALL BE
5 24.0M AND UPTO 30.0M 1.10 0.50 1.15 2.75 UNDER
6 30.0M AND ABOVE 1.10 0.50 1.40 3.0 A-- THERE MAY BE MAX. TWO STOREY STRUCTURE WITH MAX. BUILT UP OF 15
%. OUT OF WHICH MAX. 10% IS ALLOWED IN GROUND FLOOR AND REMAINING
D
CAN BE IN THE 1ST FLOOR
SN
1 UPTO 150
LENGTH OF INTERNAL ROAD
LENGTH OF INTERNAL ROAD WIDTH OF INTERNAL ROAD
7.5
B-- THE STRUCTURE CAN BE USED FOR PAVILION, GYM, FITNESS CLUB, CLUB
HOUSE,YOGA CENTER, LIBRARY, GENERATOR SET. ETC .
C
2
3
4
ABOVE 150 -300
ABOVE 300 - 600
ABOVE 600
9.00
12.00
15.00
C-- NO DETACHED TOILET BLOCK SHALL BE PERMITTED.
D-- A SWIMMING POOL MAY ALSO BE PERMITTED IN SUCH RECREATIONAL R
SPACE.

PROVISION FOR ELECTRICAL SUB STATION


SN LENGTH OF INTERNAL ROAD WIDTH OF INTERNAL ROAD
1 PLOT ABOVE 2000 SQ.M ONE SINGLE TRANSFORMER SU STATION OF THE SIZE
OF 5M X 5M . AND HEIGHT NOT MORE THAN 5 M

2 LAYOUT OR SUB-DIVISIION OF A PLOT MEASURING 2.0 A SUITABLE SITE FOR AN ELECTRIC SUB STATION
HA OR MORE REDEVLOPMENT- MIRA SOCIETY