Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

The new Glutograph-E

Apart from dough-rheological measure- The convincing features of the new


ments of the flour quality, e.g. with the instrument:
Farinograph®-E or Extensograph®-E,
separate quality control of wet and dry „ state-of-the-art electronic measuring
gluten as being used as a flour additive
gains more and more importance.
system Testing the
The BRABENDER® Glutograph for testing
the gluten quality has been completely
„ easy and comfortable operation via
touch-screen quality of wet
revised and now appears as Glutograph-E
with a completely new, compact design.
„ integrated computer with user-optimized
measuring and evaluation software
and dry gluten
„ printer output

Application
The Glutograph-E represents the state of
the art on the sector of gluten testing.
The instrument enables

„ reliable, objective, and reproducible


measurement of the stretching and
elastic properties of washed wet
gluten and of dry gluten mixed with
water to a dough
„ testing of sample weights usually
occurring in practice when gluten is
washed out
„ testing flour quality with regard to its
suitability for noodle production
„ recognition of drying and heat
damage of flour and dry gluten
State-of-the-art
The new Glutograph-E
measuring system
and software The principle
The measuring system of the Glutograph-E independent of shear angle and sample.
consists of two parallel, round, corrugated Depending on your gluten quality, this
plates mounted at a defined distance constant force (shear stress) stretches the
opposite each other. The sample is put in- sample more or less, i.e. the lower plate is
between these two plates. deflected more or less quickly against the
The fixed distance and diameter of the upper one. This deflection (shear angle) is
two plates provide for a defined sample recorded as a function of time.
volume and a reproducible sample After having reached a certain deflection,
geometry. the sample is released and recovers
While the upper plate stands still, the according to its elasticity.
lower one is turned with a constant force -

The diagram
The resulting diagram first shows the
stretching process (rising curve). The
falling curve in the second part represents
the recovery of the sample.

The shearing time (time up to reaching a


certain preset deflection) is a measure of
the stretching properties of the sample.
The recovery of the sample after a certain
time mirrors the elasticity.

Measuring diagrams of different qualities of gluten

The BRABENDER® support Technical data


A modern application laboratory is at the Sample weight approx. 2 - 3 g
disposal of all customers and interested
parties for trials with their own material. Torque measurement electronically
All BRABENDER® measuring systems
Printer port RS 232
can be tested under practice-oriented
conditions. An experienced expert team Mains connection 115/230 V, 50/60 Hz
will assist the tests and will stay at your
Dimensions (H * W * D) 300 * 310 * 520 mm
disposal at any time for further questions.
Weight approx. 12 kg
Apart from that, numerous articles dealing
with the application of the BRABENDER®
instrument systems for manifold tests have
been published all over the world during the
past decades. We shall be pleased to send
you a bibliography comprising about 1500
articles at present.

Together, we will find the optimum


solutions for your special problems and
prove their suitability. Subject to change of design and technical modification without notice.

BRABENDER® agencies all over the world.


© 2005 BRABENDER® GmbH & Co. KG DUISBURG
All trademarks are registered.

BRABENDER® GmbH & Co. KG DUISBURG y Kulturstr. 51 - 55 y 47055 Duisburg y Germany 012005
Phone: +49 (0) 203 / 7788-0 y Fax: +49 (0) 203 / 7788-102 15049 E
E-Mail: food-sales@brabender.com y Internet: www.brabender.com