Professional Documents
Culture Documents
Life Test Report of TT1116YLA
Life Test Report of TT1116YLA
, ltd,
LIFE TEST REPORT OF TT1116YLA COMPRESSOR
J14091011‐‐‐‐‐‐THE WEARTEST for 500 HOURS
J14091012‐‐‐‐‐‐HIGH TEMPERATURE TEST FOR 2000 HOURS
J14091013‐‐‐‐‐‐SWITCH TEST FOR 500000 CIRCLES
Jiaxipera Compressor co., ltd,
December, 30, 2014
R600a 1
Life Test Report Jiaxipera Compressor co., ltd,
1. Test condition
The wear test for 500 hours
Suction Discharge Evaporating Condensing
Ambient Temperature
Refrigerant Pressure Pressure Temperature Temperature
(oC)
(MPa) (MPa) (oC) (oC)
R600a 0.11±0.05 1.64±0.15 ‐10±3 90±3 20±5
The high temperature test for 2000 hours
Suction Discharge Evaporating Condensing
winding Temperature
Refrigerant Pressure Pressure Temperature Temperature
(oC)
(MPa) (MPa) (oC) (oC)
2. 500 hours wear test (Compressor no. J14091011)
After the wear test, the compressor can running normally. It must not have an excessive
wear. The compressor noise can’t increase more than 3dB, the cooling capacity can’t reduce
more than 5%, and COP can’t reduce more than 5%.
(1) Performance test result (Compressor no. J14091011)
Capacity Deviation COP Deviation Noise Deviation vibration Evaluation
Test
(W) ≤‐5% (W/W) ≤‐5% dB(A) ≤+3dB m/s2
R600a 2
Life Test Report Jiaxipera Compressor co., ltd,
(2) The oil color rising must less than 11 point ( Standard SH/T0168‐92)
Oil color
Compressor no. Deviation Evaluation
Before test After test
J14091011 2 3 1 pass
(3) Compressors photos
R600a 3
Life Test Report Jiaxipera Compressor co., ltd,
3. High temperature test (Compressor no. J14091012)
After high temperature test, the compressor can run normally. It must not have an excessive
wear. The noise can’t increase more than 3dB, the cooling capacity can’t reduce more than
10%,COP can’t reduce more than 10%.
(1) Performance test result (Compressor no. J14091012)
(2) Oil test
The oil color deviation must less than 11 point ( STANDARD SH/T0168‐92)
Oil color
Compressor no. Deviation Evaluation
Before test After test
J14091012 2 7 5 pass
(3) Compressors photos
R600a 4
Life Test Report Jiaxipera Compressor co., ltd,
4. The switch test (Compressor no. J14091013)
After 500000 circles switch test, the compressor can running normally. It must not have an
excessive wear. The noise can’t increase more than 5dB, the cooling capacity can’t reduce more
than 10%, and COP can’t reduce more than 10%.
(1) Performance test result (Compressor no. J 14091013)
Capacity Deviation COP Deviation Noise Deviation vibration
No. Evaluation
(W) ≤‐10% (W/W) ≤‐10% dB(A) ≤+5dB m/s2
(2) Oil Color
The oil color rising must less than 11 point ( STANDARD SH/T0168‐92)
Oil color
number Deviation Evaluation
before test after test
J14091013 2 8 6 Ok
R600a 5
Life Test Report Jiaxipera Compressor co., ltd,
(3) Compressors photos
5. The parts evaluation
Parts surface quality evaluation (visual analysis)
Compressor Discharge Suction Connecting rod Crankshaft
No. valve valve big hole small hole shaft eccentric shaft
J14091011 2 2 2 2 1 2
J14091012 3 2 2 2 2 2
J14091013 3 2 2 1 2 2
R600a 6
Life Test Report Jiaxipera Compressor co., ltd,
Crankcase
Compressor
The shaft The support Piston Piston pin Valve plate
No. Cylinder
assembled hole surface
J14091011 2 1 2 2 2 2
J14091012 2 1 2 2 2 3
J14091013 2 2 2 2 2 2
Definition of the ranks.
Value Wear Characteristic Definition
Looks like new No polish, no evidence of wear
1 Very slight wear Very light polishes over small area, no surface defects, no scratches. The
worn surface is smoother than the virgin surface
Slight wear Light polish over small area, light scratches, light surface defects. The worn
2
surface is smoother than the virgin surface.
Moderate wear ModLight scratching, moderate polish, no surface fractures, no scuffing, no
gouging. The amplitude of the surface defects is of the same order as the
3
virgin surface. The amplitude of the surface defects relative to the virgin
surface is of the order of less than two to one.
Mild aggressive Moderate scratching, mild abrasive wear, mild scuffing, heavy polish, mild
4 wear surface fractures, heavy polishing. The amplitude of the surface defects
relative to the virgin surface is of the order of greater than two to one.
Aggressive wear Severe scratching, severe abrasive wear, gouging, scuffing, surface fractures,
break down of surface, very heavy polishing, fretting, galling. The amplitude
5
of the surface defects relative to the virgin surface is significantly greater
than two to one.
Key parts inspect results
Connecting rod
Parts Piston
The big hole The small hole
Δ(%) Circle Δ(%) Circle Δ(%) Circle
Inspect Items Rt Rt Rt
Rq degree Rq degree Rq degree
Inspect
7.5↓ 10μm↓ 15↓ 7.5↓ 10μm↓ 15↓ 7.5↓ 10μm↓ 15↓
requirements
J14091011 1.32 0.09 0.53 2.08 0.42 2.59 1.96 0.22 1.55
J14091012 0.9 0.18 1.28 1.26 0.32 2.11 1.36 0.3 2.09
J14091013 0.6 0.28 1.25 1.57 0.27 1.73 1.48 0.29 2.13
Judgment OK OK OK OK OK OK OK OK OK
R600a 7
Life Test Report Jiaxipera Compressor co., ltd,
Crankshaft
Parts Piston pin
eccentric long shaft
Δ(%) Circle Δ(%) Circle Δ(%) Circle
Check Items Rt Rt Rt
Rq degree Rq degree Rq degree
Check
7.5↓ 6μm↓ 7.5↓ 7.5↓ 10μm↓ 7.5↓ 15↓ 15μm↓ 15↓
requirements
J14091011 0.92 0.31 3.09 0.95 0.22 1.66 0.54 0.1 0.81
J14091012 0.4 0.2 1.39 1.04 0.19 1.39 0.4 0.16 1.03
J14091013 0.51 0.34 1.94 1.27 0.27 4.15 0.41 0.06 0.44
Judgment OK OK OK OK OK OK OK OK OK
Crankcase Suction Discharge
Parts
The shaft assembled hole Cylinder valve valve
Δ(%) Circle Δ(%) Circle
Check Items Rt Rt Rt Rt
Rq degree Rq degree
Check
7.5↓ 10μm↓ 15↓ 7.5↓ 6μm↓ 15↓ 15↓ 15↓
requirements
J14091011 0.28 0.3 3.25 0.21 0.26 3.21 / /
6. Conclusion
Test item Compressor no. conclusion
Compressor evaluation Ok
R600a 8