1. General information
2. Document overview
0001 06/13/2019 Size II Interstage pipe housing bolts unsatisfied torque Li Hua Luo
3. Revision History
This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
05/13/2019 Page 1 of 3
4. Reason for this bulletin
All machines of using interstage pipe housing (1626090300) with risk of bolts loosen due to unsatisfied torque. It might
cause oil leakage from element.
5. Description
6. Application
OEM XRHO1550; XRXS1210; XRYS1150; XRVS1300; XRVS1350; XRXS1275; XRXS1240; XRXS567; XRVS617;
XRVS647; XRXS607; OTMXRHO1550; XRHS1550; Y1260; Y1200; Y1300; X1300; V1200; XRHS1150; OTM XRHO1150;
XRVS1050; XRVS487; XRHS527; OTM XRVS1050; XRHS930E; XRVS960E; XRHS1150E; OTM960E; XRHE1300;
OTM XRYE1050
7. Required parts
No required parts.
No required parts
9. Reimbursement criteria
10. Reporting
The operator must employ safe working practices and observe all related local work safety requirements and regulations.
This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
05/13/2019 Page 2 of 3
• Maintenance must only be performed by authorized and trained personnel.
• Before starting any work on the equipment, stop the equipment, switch off the voltage, and press the emergency
button. In addition, the power isolating switch must be opened and locked.
• Refer to the Instruction book and/or workshop manual for any additional safety precautions
• Disconnect any remote start controller
• A ‘Work in progress; do not start’ warning sign shall be attached to the starting equipment.
• All maintenance work shall only be undertaken when the equipment has cooled down.
• Effectively isolate the machine from all sources of pressure and / or electrical power and relieve the entire system of
pressure.
• Use only the correct tools for maintenance and repair work.
• Observe cleanliness during maintenance and repair. Cover parts and exposed openings.
• Make sure that no items are left behind in or on the equipment.
• All regulating and safety devices shall be maintained to ensure correct functionality.
They will not be put out of service.
• Always wear personal protective equipment (Work clothing, safety shoes, safety goggles, ear protection, safety
gloves,…)
This is an Atlas Copco internal document. It is not to be shared with distributors, dealers or customers!
05/13/2019 Page 3 of 3