Professional Documents
Culture Documents
P. O. BOX: 32076 Doha-Qatar Tel: 40324100 Fax: 40324112: 1 8 1 0 Table of Contents
P. O. BOX: 32076 Doha-Qatar Tel: 40324100 Fax: 40324112: 1 8 1 0 Table of Contents
Table of Contents
SECTION 1. INTRODUCTION.
1.1. ACICO Introduction ................................................................................................. Section 1, Page 2
1.2. ACICO Products ....................................................................................................... Section 1, Page 3
1.3. Specification of ACICO AAC Products ...................................................................... Section 1, Page 4
1.4. ACICO Contacts & Location ..................................................................................... Section 1, Page 6
SECTION
(1)
Introduction
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
This material Submittal document covers ACICO - Aerated Concrete Industries Co. W.L.L.
material details; Physical properties, Safety Data Sheet, Technical Data Sheet of Autoclave Aerated
Concrete AAC.
1.1. ACICO Introduction.
Qatar Aerated Concrete Industries Co. W.L.L. was established on 13th November, 2005 as a
joint venture between Nasser Bin Khaled & Sons Holding Co. (51%) and Kuwait based ACICO
Industries (49%). The company was established to cope up with the demand for AAC Sustainable
building materials in the construction industry of Qatar, in keeping with the architectural renaissance
taking place in the State of Qatar nowadays.
Currently AAC production growing and widespread in Gulf area. However, in other parts of
the world it has been used successfully as a building material for over fifty years. Concrete masonry
material that is lightweight, easy to construct, and economical to transport. Its light weight is
accomplished through the use of evenly distributed microscopic air bubbles throughout the material;
these bubbles result in a lightweight concrete that is composed of a latticework around spherical
voids.
We Produce Autoclaved Aerated Concrete (AAC) both Reinforced Building materials such as
Wall Panels(Exterior &Interior), Floor / Roof Slabs, Lintels, Stairs and Non-Reinforced building
materials such as lightweight blocks and jumbo blocks of different sizes. Could be used for Exterior &
Interior walls. With the latest technology available today.
Porduction Process
ACICO blocks are suitable for load bearing and non-load bearing walls. ACICO blocks are
delivered ready for use and packed in easily transportable wooden pallets. The pallet should be
unloaded at the site by a construction site crane, forklift truck or other suitable hoisting
equipment. Never dump them from the truck.
ACICO blocks are produced to extremely narrow dimensional tolerances of 001mm. They are
therefore laid by the thin-bed mortar (glue) method. The joint is 3-5 mm thick. ACICO blocks for
infill masonry y are the logical advancement in development of ACICO blocks with Tongue and
Grove.
ACICO lintels are available in various sizes to cover wide range of openings for doors, windows
etc. Since they are constructed from the same material as ACICO blocks, the surfaces are easily
finished and the possibility of cracks due to different thermal expansion is reduced. ACICO lintels
facilitate work on site, maintain insulation and avoid thermal bridges caused by the use of
traditional concrete lintels. The traditional method for preparing concrete lintels requires much
work such as shuttering, preparing of reinforcement and it is also much more time consuming.
ACICO lintels are produced according to code DIN EN 12605. The reinforcement is anti-corrosive
protected like other reinforced ACICO slabs and panels. Standard lintels are designed for a
minimum 20 cm support at both ends with a maximum span between supports of 260 cm.
1.2.3. ACICO AAC Slabs and Wall Panels.
ACICO Slabs and Wall Panels are reinforced aerated concrete products which are produced in
accordance to code DIN EN 12605. Being ready-to-use, prefab structure elements have their full
load-bearing capacity directly after production.
After delivery, slabs can be simply erected in a short time. There is no need for shuttering work.
Only the joints must be grounded with concrete.
ACICO thin-bed Mortar (glue) is an adhesive mortar tor quick and firm laying of ACICO blocks
with thin joints. It is used to bind ACICO blocks into masonry with high stability. ACICO glue is
manufactured from fin sand, cement and some adhesives, resulting in good bonding properties.
The thickness of the joints 3-5 mm, thus preserving the unique thermal-insulation qualities.
ACICO repair mortar is specially produced only for the AAC products and is not common in the
market. The component of the AAC products is the same material which is used to produce the
repair mortar and this component to be exactly the same properties of AAC products.
Appearance : Powder
Color : White
Open time : 30 minutes at standard conditions
Tensile adhesion under regular
: > 2.5 N/mm2 after 7 days
conditions
Tensile strength by open time : > 0.5 N/mm2 after 30 Minutes
Max. Time for application :
Recommended Max Thickness : 5 mm
Consumption : 3-4 kg/m2
Package : Multi-Layer Bag of 25 kg Weight
Shelf Life : 6 months in well closed original bags if stored as recommended
Storage : Store in dry covered places in the original closed bags.
ACICO Glue is a cement- based product.
Health & Safety : Avoid contact with skin or eyes. Provide adequate ventilation in
working places to avoid inhalation of dust.
Flexural Strength
Prism 4x4x16cm 2.8 N/mm2
Storage: 23 c/50% r.h.
Compress Strength
Prism 4x4x16cm 10.0 N/mm2
Storage: 23 c/50% r.h.
Dry bluk density
Prism 4x4x16cm 1.3 Kg/m3
23 c/50% r.h.
Adhesive Strength
On Concrete, 5mm Layer thickness N/mm2
23 c/50% r.h.
Standard deviation 0.1 N/mm2
Fracture b
7 days 23 c/50% r.h. + 21 days .H2O 2.0 N/mm2
Standard deviation N/mm2
Fracture b
Legend: a: Adhesions fracture b: Cohesion fracture in mortar c: Cohesion fracture in Substrate
Location Map
https://goo.gl/maps/4qWSLvThwA92
SECTION
(2)
Licenses
&
Certifications
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
Table of Contents
1.1. Trade License. ..............................................................................................................................2
2.4. Gulf Organization for Research & Development Certificate (GORD) (GSAS). ...................................7
2.7. OHSAS 18001:2007, Occupational health and Safety Management Systems. ............................... 10
1.1.Trade License.
SECTION
(3)
Material Safety
Data Sheet
(MSDS)
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
3.2. MSDS Mortar (Thin bed Mortar & Repair Mortar). ........................................................................7
3.2.1. Identification of the substance / preparation and of the company / undertaking. ....................... 7
3.2.2. Hazards identification. .................................................................................................................... 7
3.2.3. Composition / Information on ingredients..................................................................................... 7
3.2.4. First aid measures. .......................................................................................................................... 8
3.2.5. Fire-Fighting measures. .................................................................................................................. 8
3.2.6. Accidental release measures. ......................................................................................................... 8
3.2.7. Handling and storage...................................................................................................................... 9
3.2.8. Exposure controls/Personal protection. ......................................................................................... 9
3.2.9. Physical and chemical properties. ................................................................................................ 11
3.2.10. Stability and reactivity. ................................................................................................................. 11
3.2.11. Toxicological information. ............................................................................................................ 11
3.2.12. Ecological information. ................................................................................................................. 12
3.2.13. Disposal considerations. ............................................................................................................... 12
3.2.14. Transport information. ................................................................................................................. 13
3.2.15. Regulatory information. ............................................................................................................... 13
3.2.16. Other information. ....................................................................................................................... 13
Hazards description:
This product does not contain hazardous parts which are about the level of the EC regulation.
Nonetheless the dust deriving from the construction material (e.g. drilling, sawing) can cause hazards
as follows:
Irritating to skin.
Risk of serious damage to eyes.
May cause sensitization by skin contact.
Personal precautions:
Use safety goggles or safety glasses when working in a dust atmosphere e.g.
drilling or sawing the blocks
Environmental precautions:
None
3.1.7. Handling and storage.
o Unload block using forklifts. Consult an appropriate safety consultant or knowledgeable OSHA
trainer for “rigging” or other safety considerations.
o Stored areas should be accessible to delivery trucks and convenient to material staging areas.
If possible, drop-deliver the material right to the material staging areas.
o Storage material should always be stored away from other construction activities on a flat-
grade area that is not susceptible to standing water, erosion or settling.
o Keep the material covered and packaged until ready for installation.
o Excessive handling may cause damage. Set delivery schedule to match the erection sequence.
o Chips and spalls can be repaired. All damaged surface areas may be repaired using a
compatible AAC patching compound.
o Stored or staged materials should always be set on flat, stable grade on pallets.
o Observe and provide all necessary temporary support and bracing in addition to following all
safety laws and requirements.
Caution: Use safety gear: Hard hat, gloves, dust mask and goggles to avoid excessive inhalation of
dust and protection of the eyes when handling ACICO AAC.
Occupational
exposure limit Recommended
Country of Substance Peak
EC-No CAS-No value monitoring Source
origin name limitation
procedures
(mg/cbm)
TRGS
D O.P. Cement 266-043-4 65997-15-1 5 Measuring -
900
Respirable TRGS
D - - 3 Measuring -
dust 900
O.P. Cement -
UK 266-043-4 65997-15-1 10 Measuring - EH 40
Inhalable dust
O.P. Cement -
UK Respirable 266-043-4 65997-15-1 4 Measuring - EH 40
dust
a. Appearance:
Physical state: solid
Colour: different
Odour: none
Conditions to avoid:
none
Materials to avoid: (dust gives high temperature reaction with the following materials:
Acids
Hazardous decomposition products:
above 550°C
3.1.11. Toxicological information.
Ecotoxicity:
None known
3.1.13. Disposal considerations.
EU-regulations:
Labelling (according to 67/548/EC or 1999/45/EC):
no labelling
Signal words, R-phrases:
no R-phrases
Safety advice, S-phrases:
S 22 Do not breathe dust
S 37 Wear suitable gloves
Specific rules for supplemental label elements for certain mixtures: see below (applicable only
in the European Community)
Authorizations and/or restrictions on use:
REACH: Regard restrictions of No. 47 concerning Chromium (Annex XVII of REACH)
Directive 2003/53/EC: hexavalent chromium in cement
National regulations:
Restrictions of occupation:
Legal protection of working mothers and the working youth must be considered
Water hazard class: none
German air quality regulation (TA Luft): 50 mg/cbm
3.1.16. Other information.
Hazards description:
Classification:
Hazards characteristics R-Phrases
Xi - Irritant R 36/38, 41, 43
3.2.3. Composition / Information on ingredients.
Contains further sand, non-hazardous fillers and additives to ensure proper product quality
and contains minimal quantities of Chromium VI (approx. 10 ppm)
Full text of R-phrases; see section 16
b. Repair mortar.
Amount Classification according
Chemical name EC-No CAS-No
(%) 67/548/EC
White cement 266-043-4 65997-15-1 30-45 Xi, R 36/38, 41, 43
Calcium
215-137-3 1305-62-0 7 - 15 % Xi, R 41
Hydroxide
REV. 201710 Section 3 - Page | 7
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
General information: Product produces an alkaline reaction when wet. Product may
produce allergic reaction, irritant to skin, Risk of serious damage
to eyes.
In case of inhalation: Move the exposed person to fresh air at once. Have the victim
blow his or her nose and/or remove particulates or residues
from the nostrils. If nose or airways became inflamed seek
medical help.
In case of skin contact: Wash the skin immediately with plenty of clean water for at
least 10 minutes; Contact a doctor if irritation continues over a
longtime.
In case of eye contact: Remove any contact lenses from the eyes before rinsing!
Promptly wash eyes with plenty of clean water while lifting the
eye lids. Continue to rinse for at least 15 minutes.
In case of ingestion: Wash mouth with clean water! Do not induce vomiting.
Never make an unconscious person drink fluids.
Self-protection of first aider: Don’t let the product react with water.
Information to physician: -
3.2.5. Fire-Fighting measures.
Personal precautions:
Avoid dust formation
Avoid contact of product with water
Use safety goggles or safety glasses with side shields
Environmental Precautions:
Avoid entry into sewers, water courses or the soil.
Methods for cleaning up:
REV. 201710 Section 3 - Page | 8
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
Handling
Advices on safe handling:
Do not open long before usage
Keep in a dry and cool place
Sufficient illumination when working during dark hours
Protective measures:
Keep water and humidity away from storage facilities
Avoid dust formation by reducing height of falling when handling the product
Technical measures: none
Specific requirements or handling rules:
Only store in original packing.
Precautions against fire and explosion:
product is not flammable
Further information: none
Storage:
Technical measures and storage conditions
Avoid strong air movements in storage places of product by walls or other partitions
Hints on storage assembly:
Keep away from acids and water
Storage class: VCI storage class 13 (VCI = Society of German chemical industry)
Further information on storage conditions: none
3.2.8. Exposure controls/Personal protection.
3.2.9.1. Appearance:
Physical state: dust
Colour: grey
Odour: none
Conditions to avoid:
humidity (strong heat development with water)
Materials to avoid: (dust gives high temperature reaction with the following materials:
acids,
light metal like aluminum alloy
phosphorus
hydrosulphide
organic nitro compounds
Hazardous decomposition products: above 550°C
3.2.11. Toxicological information.
Further effects:
Irritating to skin
When contact to sweat danger of caustic effects
Risk of serious damage to eyes, in extreme cases up to blindness ( e.g., if no first aid
is given)
May cause sensitisation by skin contact
CMR effects (carcinogenity, mutagenity and toxicity for reproduction): chromium six conThint
b. Repair Mortar.
Acute effects (toxicity tests):
Calcium Oxide Effect dose Species Remark
Acute oral toxicity LD 50: >5.000 mg/kg Rat -
Calcium Oxide
Acute oral toxicity LD 50: 7.340 mg/kg Rat -
Further effects:
Irritating to skin
When contact to sweat danger of caustic effects
Risk of serious damage to eyes, in extreme cases up to blindness ( e.g., if no first aid
is given)
May cause sensitization by skin contact
May cause severe lung diseases if inhaled for a very long period
CMR effects (carcinogenity, mutagenity and toxicity for reproduction): chromium six conThint
3.2.12. Ecological information.
Ecotoxicity:
Effect dose Species
Ca (OH)2 LC 50: 160 mg/l / 96 h (IUCLID) Gambusia affinis
Product becomes hardened after mixing with water after 5 – 8 hours and can be disposed of as
construction waste
Waste codes / waste designations according to EWC / AVV: 17 09 04 (hardened) or 17 09
03* (non-hardened)
Additional information: none
3.2.14. Transport information.
EU-regulations:
Labelling (according to 67/548/EC or 1999/45/EC):
Xi Irritant
SECTION
(4)
4.2. ACICO Lintels, Technical Data sheet & Method of Statement. ........................................................9
4.3. ACICO Glue Mortar (Thin-bed Mortar), Technical Data Sheet & Method of Statement..................12
PROPERTIES.
Strength Class
Characteristic Units
G2/05 G4/06
Dry Density 500 600 Kg/m3
Thermal Conductivity 0.13 0.16 W/m k
Compressive Strength 3.2 5.0 N/mm2
Fire Rating 4 4 Hrs.
Ver. 1811 Section 4- Page | 2
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
THERMAL INSULATION.
“U-value” Overall
“K” Thermal “R” Thermal
Thickness heat transfer
Strength Category Conductivity Resistance
(mm) coefficient
(W/m k) (m2k/W)
(W/m2k)
100 0.77 1.06
150 1.15 0.75
AAC Block
0.13 200 1.54 0.58
Class G2/05
250 1.92 0.48
300 2.30 0.40
100 0.63 1.25
150 0.94 0.90
AAC Block
0.16 200 1.25 0.70
Class G4/06
250 1.56 0.58
300 1.88 0.49
FIRE PERFORMANCE.
BS 476: Part 22:1987
ACICO AAC Block Class G2/05 Class G4/06
Size (mm) Integrity Insulation Integrity Insulation
(minutes) (minutes) (minutes) (minutes)
100 120 120 120 120
150 240 240 240 240
200 240 240 240 240
250 240 240 240 240
300 240 240 240 240
350 240 240 240 240
400 240 240 240 240
ACOUSTIC PERFORMANCE.
STC
Thickness Class G2/05 Class G4/06
(mm) Without With plaster on Without With plaster on
plaster both sides plaster both sides
100 37 48 40 49
150 41 48 43-44 50
200 43 49 46 51
250 46 51 48 52
300 48 52 49-52 53-55
4 fixed edges by figure C.2. 3 fixed edges (free edge top) by figure C.5.
Height h Thickness t Height h Thickness t
m mm m mm
200 250 300 350 400 200 250 300 350 400
Maximum length l [m] Maximum length l [m]
3 6.40 10 12 14 16 3 3.8 5.25 6.9 8.75 10.4
3.5 5.2 8.5 12 14 16 3.5 3.6 4.75 6.45 8.05 9.6
4 4.4 7.5 11.4 14 16 4 3.4 4.5 6 7.52 9.2
4.5 4 6.25 9.6 14 16 4.5 3.3 4.37 5.7 7 8.8
5 3.8 5.5 8.1 11.9 16 5 3.2 4.25 5.4 6.65 8.4
BONDING DETAILS
If there is an inter looking between the blocks, there is no need for using the wire
mesh or steel plate in connecting partition walls. The only thing needed is a steel angle or a
steel connection between ACICO blocks and the concrete column each (3-4) layers.
a. CONNECTING BY MASONRY BONDING.
e. FIXING OF LINTELS.
Lintels should be laid on ACICO Lightweight blocks or normal blocks with a minimum
of 15-20 cm support at both ends.
*For more details, check Technical data sheet & method of statement for ACICO lintel.
f. RECOMMENDED COMPANIES FOR ACCESSORIES.
CATNIC.
EXMATE.
Or equivalent.
g. RECOMMENDED COMPANIES FOR FISHERS AND NAILS.
HILTI.
FISCHER.
Or equivalent.
4. It is recommended to lay ACICO Lintel in thin bed mortar (glue) especially with ACICO Blocks.
5. The glue thickness is about 3-5 mm, generally cement mortar can be also used.
6. Small damage can be repaired by using ACICO repair mortar (or cement mortar), but never
repair big damages. Also, it is not permitted to cut the Lintel.
7. It is recommended to fix these lintels with minimum fixation of 20 cm from each side on the
block.
8. In case the lintel is attached directly to the column a steal angle of 90x90x9 mm should be
used and it should be fixed to the concrete column by fisher plug GB10.
9. In case lintels should be applied with a minimum distance less than 20 cm (obligatory
application NO space available) some condition should be taken into consideration.
The distance should not go under 15 cm.
A steal par should be inserted in the already
existing hall in the edge of each lintel this
bar should reach the block under it with a
distance of minimum 15 cm.
4.3. ACICO Glue Mortar (Thin-bed Mortar), Technical Data Sheet & Method of Statement.
DESCRIPTION.
ACICO Glue Mortar is a high quality, water resistant adhesive for permanently fixing AAC
blocks. The product is a cementations powder, available in white or grey that only requires the
addition of clean water on site. It has been specially formulated for the tropical conditions of the
Middle East and will tolerate wet or damp conditions.
FEATURES.
High Initial bond strength.
Economic.
Water resistant.
Typical for Middle East Tropical conditions.
USES.
ACICO Glue Mortar can be used for laying internal and external Autoclaved Aerated Concrete
Blocks, Lintels and walls Panels.
PRECAUTION.
Prepare the quantity that is enough for not more than two hours. (In summer season for not
more than one hour and add water to AAC material surface prior to install the mortar). In case glue
mortar gets dry because of long use - don’t mix with water again!
TECHNICAL DATA.
Properties listed are only for guidance and are not a guarantee of performance
Method of Statement.
Surface Preparation:
All surfaces should be sound and free of contamination from dust, debris, loose particles of
mortar, wallpaper, paint, etc. All traces of oil and grease should be removed with a chemical
degreaser.
ACICO Glue Mortar can be applied directly onto concrete, cement screeds and cement or line
mortar. On new construction.
Mixing:
5 -5.5 liters of water is required for each 25kg bag of ACICO Glue Mortar. A slow speed drill fitted
mixing paddle is recommended for mixing in a minimum capacity of 30L. Always pour the powder
into the recommended quantity of water while the mixer is running, slowly add the bag of powder
and mix for 3 minutes until a uniform and lump free consistency achieved. It is important that the
powder is always added into the water - do not pour water into the powder component.
Application:
The first line of block should be lined on a traditional bed of cement mortar.
Applied ACICO glue with a special toothed trowel and then position the blocks to be
leveled. Remove possible excess of mortar before it hardens.
The glue should be applied in a thin layer to enable the continuity of thermo insulation of
the block.
Leave a space of about 2 cm between the top of the block wall and the bottom of the slab
or beam in order to avoid formation of cracks along the wall this cavity should be filled
with compressible materials.
Cleaning:
Wet product should be removed from tools and equipment with clean water immediately after
use. Cured material should be removed mechanically.
Limitations:
ACICO Glue Mortar is available in 25kg bags and has a shelf life of 12 months when stored in
unopened bags, off the ground, under cover out of direct sunlight, and in cool, shaded and dry Ware-
houses at temperatures between 2°C and 30°C In extreme tropical climate, the product must be
stored in cooled ambience. Excessive humidity and over exposure to UV will result in the reduction of
shelf life. ACICO Glue Mortar is non-flammable.
ACICO Glue Mortar contains cement powders which, when mixed with water or becoming
damp, release alkalis which can be damaging to the skin so the use of gloves and a barrier cream is
recommended. As with all construction chemical products, caution should always be exercised.
Protective clothing such as gloves and goggles shall be worn whilst handling. Wearing long sleeve
overalls, safety shoes and face mask is recommended for maximum safety. If any material comes in
contact with the skin it should be removed with water – DO NOT use solvent. Treat any splashes to
the eyes with fresh water immediately and seek medical assistance. Should any of the product be
accidentally swallowed, do not induce vomiting, but call for medical assistance immediately.
Spillages of ACICO Glue Mortar should be swept up and transferred to suitable containers for
disposal. The disposal of spilt or waste material should be carried out in accordance with local
legislation under the guidance of the local waste regulatory authority.
Limited Warranty:
It is the responsibility of the customer to determine the suitability of the product for the
intended purpose. Factors such as temperature, surface preparation and applicator’s skill are beyond
the control of the company. Therefore, the manufacturer’s liability is limited to the replacement of
the defective material only.
Autoclave Aerated concrete AAC blocks & Wall panels are a cement base so plaster
can be applied normally on it. With taking into consideration the strength of material
applied which should be
Plaster material that can be applied to AAC Blocks or Wall-panels.
1. ACICO Gypsum Lime Plaster. (Internal use only).
2. Ready Mix Plaster.
Which is available in Qatar market (it is a mixture that need only to be mixed with
water and applied with a thickness between 8 mm to 15 mm after applying thin layer of
rush coating material that came special with the plaster (Note compression strength of
plaster material should be the compression strength of block.
(Applicable if max 3.8 N/mm2)
3. Normal Traditional Plaster.
Can be used after applying a special layer of rush coating for AAC Block with an
average thickness of 8 mm and decreasing the strength of plaster to be approximately
equivalent to the strength of AAC Blocks by obtaining a mixture with following portions 5
parts sand 1 part cement and 1 part lime.
APPLICATION OF PLASTER.
1. External Plaster should be applied with a minimum thickness of 7-10 mm.
2. Corner and angle beads should be galvanized steel.
3. For readymade plaster increasing or decreasing the quantity of water leads to expected
cracks in plaster.
4. Get rid of hardened (setting plaster. Never add water, it is useless).
CURING.
Plaster should be watered twice a day for 2 days unless technical detail mentioned other.
Windows and doors are fixed directly to AAC block without the need of using any stiffeners.
We recommend using fishers for light weight block that may be finding at HILTI or Fisher (Plastic
Plugs or Steel connection).
Note: In commercial applications, welded frames with grouted solid jambs and headers are
recommended.
FIXING WOODEN AND METAL FRAMES WITH AAC BLOCK PLEASE BE NOTED THE FOLLOWING:
1. For single leaf door it is recommended to have 6 plugs in each side with around 35 to 40cm
distance between each other.
2. Screw nails 10 cm length with wooden frames while 7.5 cm only is o.k. for metal frames.
3. For double leaf door (in addition to above no.1) the head of wooden frame should have the same
fixation.
4. Windows should fix frames all around the four sides.
TILING.
a. Internal Tiling.
One of the remarkable advantages of ACICO walls is
the plane surface due to the height quality of ACICO blocks
and thinned mortar bonding.
This advantage, allows tiling work on ACICO wall by
thin bed (cement-glue) method immediately without
plaster work. Only, probable uneven spots can be
smoothened by a sand paper and wall surfaces must be
brushed off with a hard brush before applying the cement
glue. Also, it is not necessary to wet ACICO wall before
applying the cement glue.
The cement glue method is ideal for ACICO walls
and results in remarkable advantages. It is simple and saves
time. The tiles are merely pressed into place and aligned. -
All tiles are seated over their entire area on the
understructure. Uniform quality of industrially
manufactured and ready-to-use cement-glue. No extra
expenditure for mortar material, mixer and labor.
b. External Tiling.
Performance under tough climate conditions, temperature difference, movements and
adequate bonding between external tiles and masonry is vital factor of laying external ceramic tiles.
The same bonding (cement glue) method as per internal tiling work is also recommended for
external one, but it is not preferred to fill the joints between tiles. Therefore, tiles can expand
through these joints which work as expansion joints. Whenever, joints should be filled with cement
mortar, expansion joints, filled with flexible material 2 filler should be applied in each 2M of tiles.
Further to cement glue method, it is also possible to use thick-bed cement mortar with a mechanical
connection between ACICO Wall and mortar.
4.4.5. Fastenings
There is hardly any other mineral building material with which anchoring and fastening can be
carried out so simple as with AAC lateral. But it should be done as mentioned below:
SECTION
(5)
Third-Party
Approval
Certificate
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
5.2. Acoustic AAC Density 500. AL-MANA & ASSOCIATES Acoustic Consultants. ....................................7
5.3. Acoustics AAC Density 650-700, AL-MANA & ASSOCIATES Acoustic Consultants. .......................... 11
5.2. Acoustic AAC Density 500. AL-MANA & ASSOCIATES Acoustic Consultants.
SECTION
(6)
Third-Party Laboratory
Test Report
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
SECTION
(7)
Previous Approvals
&
Projects Reference
P. O. BOX: 32076 Doha-Qatar
Tel: 40324100
Fax: 40324112
Email: info@acico.com.qa
Web: www.acico.com.qa
7.1.11. The Pearl Qatar, Viva Bahriya, Towers VB14 & VB15.
7.2.Projects Reference.