Ethan Frome

Kurzanleitung

Kollmorgen Steuerungstechnik
Olpener Straße 403
51109 Cologne
Telephone (0221) 89 85 0
Fax (0221) 89 85 30
http://www.kollmorgen.de
e-mail info@kollmorgen.de

Dokument: 483429650.doc

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 1 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 2 of 31


Ethan Frome
Kurzanleitung

Table of Contents

1 LED Displays on the Front Panel and Menu Structure.......................................

2 Change Function Values and Retrieve Event Memory..................................

3 Access Management.........................................................................................

4 Records in the Event Memory..........................................................................

5 Operating Statuses of the Control System.....................................................

6 Set-up of the Test Adapter Function...............................................................

7 Input field, Test Calls........................................................................................

8 Freely Assignable Terminals (BST 40 / network)...........................................

9 Hotline Information............................................................................................

D. KOLLMORGEN
This documentationSteuerungstechnik
and extracts from itmakes
may not
no be
guarantee
reproduced
aboutbythe
electronic
contentor
of mechanical
this documentation.
means, byD.
photocopying or by
KOLLMORGEN Steuerungstechnik
other recording processes
is not liable
or in
forany
anyother
incorrect
way, and
databrought
and consequences
into circulation
thereof
withoutin
the prior approval
connection with of
theD. supply,
KOLLMORGEN
performance
Steuerungstechnik.
or use of this documentation. D. KOLLMORGEN
Steuerungstechnik reserves the right to revise this documentation without prior notice and to make
changes to its content.

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 3 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 4 of 31


Ethan Frome
Kurzanleitung

2 LED Displays on the Front Panel and Menu Structure

5V The operating voltage for the processor is present


Run When the control system is switched on, this service indicator flashes every second
Info This LED identifies an error record in the event memory.
If there are only messages in the event memory, the Info LED does not comes on.
Gesperrt/Blocked The LED is not currently supported by the program.

U1 Control voltage is present. Serial interface


Safety circuit TD Interface sending data.
U2 The passive safety circuit is closed. RD Interface receiving data.
U3 Emergency halt is inactive. RD Interface receiving data.
U4 All door contacts are closed. S network
U5 The lift cage door contacts are closed. S data Shaft interface sending / receiving data.
U6 The interlock contact is closed. S active Shaft interface is active.
S system System error.

Direction-change equipment,
door
Tür / Door 1 Rev. “Photo cell", "Door open button" or "Pressure contact" are active.
Tür / Door 2 Rev. "Photo cell", "Door open button" or "Pressure contact" are active.

- S tru c tu re o f th e K O L L M O R G E N
F u n c t io n o f t h e m e n u b u t t o n s
m enu

The settings regarding the control system can be


In fo r m a tio n ( M a in m e n u )

found in the attached parameter printout


M a in m e n u
(S u b m e n u )

F u n c t io n s
O K Sub m enu

ESC
S e e / g iv e c a lls ( M a in m e n u ) OK F u n k tio n
Sub m enu ESC +
back to normal display

( F u n c tio n s )
O K
-
ESC
C o d e -N u m b e rs ( M a in m e n u ) OK

Sub m enu S a v e v a lu e ESC


F u n c t io n s
v a lu e n o t
saved

B a s ic S e tt in g s ( M a in m e n u )
Sub m enu

( F u n c tio n s )

S e ttin g s ( M a in m e n u )

Sub m enu

F u n c t io n s

Not all the key combinations in the various menu options are
S e ttin g s available to the user. As a guide to the user, the keys currently 3
active are displayed in the top right corner.

Other sub-options can be selected with the OK button


Before entering anything else, the RESET button must be actuated
The UP and DOWN keys are effective
The PLUS and MINUS keys are effective

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 5 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 6 of 31


Checking the event Log 4

11. July 2020


Change Function Parameters
The door open time on a car call (Door side 1) shall be changed from 4sec to 7sec .)
K O L L M O R G E N
K O L L M O R G E N
Lift Controls
Lift Controls
Lift ready to travel
Lift ready
Fl.: 1 NORMAL
Fl.: 1 NORMAL Step 1
Step 1 Select the Mainmenu
Select the Mainmenu "Information".
"Settings". Information
Settings

Step 2 OK
Step 2 OK Acknowledge the Mainmenu
Acknowledge the Mainmenu.
Information
Settings
operational Status
Doors in general

Step 3
Step 3 Select the Submenu
Select the Submenu "Event Log" .
"Doors Side 1" . Information
Settings
Event Log
Doors Side 1

Step 4 OK
Step 4 OK Acknowledge the Submenu.
Acknowledge the Submenu.
Information
Settings
Event Log
Doors Side 1

Ó KOLLMORGEN Steuerungstechnik Cologne


display
Door open time on
Car calls 4s Step 5
Step 5 OK
OK Acknowledge the function
Acknowledge the function "display".
"Door open time on car call" Event Log
Change Function Values and call up Incident Memory

Settings _
+
Err. 3 / Mess. 5
Doors Side 1
since last delete 8
Door open time on
continue with OK
Car calls 4s Step 6
Step 6 OK
+ - Step with the "OK" into the list of the event
Change the value to 7sec.
log.
Travel Monitor
Settings _
+
blocked due to trav. monitor
Doors Side 1
Tu. 25.02.97 13:45:37
Door open time on Step7 No.3 Fl.: 1 Door: -
Step 7 OK Car calls 7s Step trough the list
Acknowledge thenew value.

Page 7 of 31
Ethan Frome
Kurzanleitung
Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 8 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 9 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 10 of 31


Ethan Frome
Kurzanleitung

5 Access Management
To protect settings from unauthorised access, you can block menu options via a six-digit code. Access
management allows you 6 user levels for this. The higher the level, the more access authorisations are
available to the user. In the factory settings, no access restrictions are allowed for levels 1 – 6. The 7 th
level is reserved for the manufacturer.

The following codes are factory set:

Ebene Benutzer Codenummer

7 MPK-Service ** ** **
6 Service-Zentrale 11 22 33 Zugriffsrechte
5 DFÜ-Zentrale 70 80 90
4 Servicetechnik 2 40 50 60
3 Servicetechnik 1 10 20 30
2 Haustechnik 2 01 02 03
1 Haustechnik 1 00 00 00

Level User Code number


7 MPK service
6 Service centre Access authorisations
5 Remote data transm.
centre
4 Service technology 2
3 Service technology 1
2 Building services 2
1 Building services 1

You can change the factory-set codes for levels 1 - 6 in the menu under the “Give new code numbers ”
option.

Both individual menu options and also whole menu trees including their sub-menus (e.g. the
“Default settings” main menu) can thus be blocked. Exceptions to this rule are the "Code
number", "Log-on user", "Log-off user" and "Display user" menus. They cannot be blocked.

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 11 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 12 of 31


Ethan Frome
Kurzanleitung

6 Records in the Event Memory


This chapter contains all records in the event memory in alphabetic order. The records are sorted on the
basis of the first letters of the first word. The actual record is also supplemented by a brief description and a
list of the possible causes of the error.

Record Explanation Possible cause Type


Lift stopped No valid drive type set. · Agree valid drive type in the Default settings error
due to drive menu
Lift stopped One of the set movement check times · Check start check time error
due to movement check has expired. · Check run-time check
· Check brake check time
· Magnetic switch faulty
Lift stopped The PTC resistor of the drive has been · Thermal overload on drive error
due to PTC resistor triggered.
(motor)
Lift stopped The shaft signals are wrong. · Shaft pulses in wrong order error
due to copier error · Magnetic switch faulty
Lift stopped The SIUA.1 supervisory contact of the · Check control card settings error
due to LRV contact control card has been triggered.
Lift stopped An error has been detected during the · The re-adjustment was not completed with error
due to re-adjustment re-adjustment. the set check time
· The set number of re-adjustments has been
exceeded
· Check shaft pulses for re-adjustment
· Magnetic switch faulty
Lift stopped The control system has been blocked · No RESET actuated after a parameter error
Parameter change due to a parameter change. change in the Default settings menu
Lift stopped The main contactor monitoring has · Main contactor faulty error
due to contactor been actuated. · Main contactor contact defective
monitoring
Lift stopped The lift has stopped due to an · Check all the switch elements of the passive error
due to safety circuit interruption in the passive safety safety circuit
circuit. · Check supply voltage of the control system
Lift stopped The safety circuit has been triggered. · Check safety circuit settings error
due to safety circuit · Check safety circuit shaft signals
· Magnetic switch faulty
Event memory Time of start of records in the event message
Start on: memory.
Event memory The event memory was last deleted on message
***** deleted ***** the date stated.
Inspection The PTC resistor of the drive was · Thermal overload on drive error
PTC resistor (motor) triggered during inspection mode.
Inspection The SIUA.1 supervisory contact of the · Check control card settings error
LRV contact inactive control card was triggered during
inspection mode.
Inspection The passive safety circuit has been · Check all the switching elements of the error
Passive safety circuit interrupted. passive safety circuit
Inspection The main contactor monitoring was · Main contactor faulty error
Contact or monitoring actuated during inspection mode. · Main contactor contact defective
Inspection The supply voltage to the control · Check supply voltage to control system error
Control voltage system has been interrupted.
PTC resistor has been The PTC resistor has been triggered. · Thermal overload on drive error
triggered
Check time procedure The brake check input has been · Check brakes error
Brake check triggered.
Check time procedure The start was blocked for more than 30 error
Movement block secs.
Check time procedure The set run-time monitoring was · Check set check time error
Run-time check exceeded. · Magnetic switch faulty

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 13 of 31


Ethan Frome
Kurzanleitung

Record Explanation Type

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 14 of 31


Ethan Frome
Kurzanleitung

Record Explanation Possible cause Type


Check time procedure The set start check time has been · Check set check time error
Start check time exceeded. · Check shaft pulses in flush area
· Flush pulse set too long
· Magnetic switch faulty
Check time procedure The set brake check time has been · Check shaft pulses in flush area error
Delay check time exceeded. · Check set check time
· Magnetic switch faulty
Copier error The correction signals of both end · Check shaft signals in correction area error
Both correction circuits stops have been detected · Magnetic switch faulty
simultaneously.
Copier error When entering the destination stop · Check pulse tracks upwards and downwards error
Flush of opposite point, the other direction was not flush.
· Check pulse sequence in menu
direction · Magnetic switch faulty
Copier error The top correction switch was not · Check shaft signal in upper correction range error
No correction up detected due to a miscount in the · Check count pulses
upwards direction. · Magnetic switch faulty
Copier error The bottom correction switch was not · Check shaft signal in lower correction range error
No correction down detected due to a miscount in the · Check count pulses
downwards direction. · Magnetic switch faulty
Copier error The top correction switch was detected · Check shaft signals error
Correction up not too early due to a miscount in the · Check count pulses
expected upwards direction. · Magnetic switch faulty
Copier error The top correction switch was detected · Check shaft signals in the upper correction error
Correction up faulty in the downwards direction at a level range
which is not a final stop. · Magnetic switch faulty
Copier error The bottom correction switch was · Check shaft signals error
Correction down not detected too early due to a miscount in · Check count pulses
expected the downwards direction. · Magnetic switch faulty
Copier error The bottom correction switch was · Check shaft signals in the upper correction error
Correction down faulty detected in the upwards direction at a range
level which is not a final stop. · Magnetic switch faulty
Log-on by: {User name} The user indicated logged on his / her message
access authorisations.
Log-off by: The user indicated logged off his / her message
{User name} access authorisations.
Message: The set operating period has been message
Operating hours reached.
reached
Message: The set movement number has been message
Movement number reached.
reached
Message: One or more of the set connections of · Program version change has taken place message
Terminal connection lost the flexible terminals have been lost. · Check connections of flexible terminals
Message: The switching-on of the control system message
Program start or a keypad RESET has been
reported.
Modem error No telephone number set in MPK. · No telephone number in MPK error
No tel. number
Modem error Modem could not be initialised. · Missing or incorrect Init string error
ModemInit. wrong · Modem is not Hayes command set
compatible
Modem error MPK could not actuate the modem. · No modem connected error
Modem not ready · Modem has no power supply
· Modem connection faulty
· Modem blocked due to dialling block
Modem error MPK could not establish a valid · Other party was repeatedly engaged error
Connection not possible connection with the other party. · Other party’s telephone number wrongly
entered in MPK
Re-adjustment The set number of re-adjustment · Check re-adjustment attempt setting message
Re-adjustment no. attempts was exceeded in the stated · Oil leakage in hydraulic lifts
exceeded level.
Re-adjustment No zone signal could be entered by the · Check safety circuit error
No zone at re- control system before the re- · Magnetic switch faulty

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 15 of 31


Ethan Frome
Kurzanleitung

Record Explanation Type

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 16 of 31


Ethan Frome
Kurzanleitung

Record Explanation Possible cause Type


Re-adjustment During the re-adjustment, an error was · Check safety circuit error
Safety circuit reported by the safety circuit. · Magnetic switch faulty
Re-adjustment The re-adjustment did not end within · Check check time settings error
Time-out the set check time. · Lift jammed during re-adjustment
· Magnetic switch faulty
Re-adjustment During the re-adjustment, the zone · The switch-off condition of the re-adjustment error
Zone left area was left. was not recognised
· Check shaft signal for re-adjustment
· Magnetic switch faulty
Emergency call The “Emergency call” input became message
actuated active.
Emergency power mode The number of permitted movement · Errors causing a halt in the movement and / message
Attempt no. reached attempts set via the menu for the or preventing the lift from starting
emergency power level was exceeded.
Safety circuit during A shaft door was opened while moving. · Door was opened via the emergency lock error
movement release
External door opened
Safety circuit during The passive safety circuit was · Check all the switching elements of the error
movement interrupted. passive safety circuit
Passive safety circuit
Safety circuit during The internal door was opened while · Check lift car door contact or door limit error
movement moving. switch
Internal door opened
Safety circuit during The emergency top limit switch has · Interruption in the passive safety circuit error
movement been interrupted. · Check emergency limit switch
Emergency limit switch
Safety circuit during An interlock contact was interrupted · Check door locking error
movement while moving.
Interlock interrupted
Safety circuit during The supply voltage of the control · Check supply voltage of control system error
movement system has been interrupted.
Control voltage
Safety circuit The passive safety circuit has been · Check all the switching elements of the error
Passive safety circuit interrupted. passive safety circuit
Safety circuit The emergency top limit switch has · Interruption in the passive safety circuit error
Emergency limit switch been interrupted. · Check emergency limit switch
Safety circuit The supply voltage of the control · Check supply voltage of control system error
Control voltage system has been interrupted.
Safety circuit The safety circuit signals an error. · Check safety circuit error
Input triggered · Magnetic switch faulty
Safety circuit The safety circuit reports an error. As a · Check safety circuit error
Early doors & re-adj. off response, the doors opening early and · Magnetic switch faulty
the re-adjustment are switched off.
Safety circuit At flush, no zone signal could be · Check safety circuit error
No zone in the status entered by the control system. · Zone switch faulty
Voltage monitoring The voltage monitoring of the control · Short-circuit where consumer has 24V error
Short-circuit term. 200 system has been triggered. supply
· Check shaft wiring
Voltage monitoring The monitoring of the light voltage has · Check light power supply error
Light voltage been triggered.
Voltage monitoring The process voltage +24V has been · Check processor supply voltage error
Processor +24V interrupted.
Door fault The door indicated jams when opening. · Check door drive error
Jams during opening · Check door mechanism
· Check door limit switch OPEN
Door fault The door indicated jams when closing. · Check door drive error
Jams during closing · Check door mechanism
· Check door limit switch CLOSE
Door fault The photoelectric barrier has jammed · Check photoelectric barrier error
Photoelectric barrier or is faulty.
jams
Door fault The set time for interlock release is too · Increase interlock release time error
Interlock release too short. · Check interlock mechanism
short

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 17 of 31


Ethan Frome
Kurzanleitung

Record Explanation Type

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 18 of 31


Ethan Frome
Kurzanleitung

Record Explanation Possible cause Type


Door fault The set locking check reports · Check door drive error
Locking unsuccessful unsuccessful locking of the door. · Check door mechanism
Block access An attempt has been made to block all · Too many accesses blocked via expansion message
Too many levels levels at the same time. modules
blocked · Too many accesses blocked via the menu

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 19 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 20 of 31


Ethan Frome
Kurzanleitung

7 Operating Statuses of the Control System


T r a v e l to F lo o r 6 The control system has a range of operating statuses. The 3 most important of
D o o rs c lo s in g them are shown on the normal display. You can find an overview of all these
L a n d in g C o n tr o l o ff statuses in the “Information” main menu.
F l.: 1 S p e c ia l

The operating status table is sorted by the initial letter of the 1st word.

Operating status Explanation


Lower level reached After the return movement, arrival at the lower level is displayed in hydraulic lifts.
Travel down The downwards movement in hydraulic lifts to the set level is being carried out.
Lift ready for use No lift jobs currently in progress.
External control off The external control system is switched off.
Fire mode Fire mode has been started.
Fire level reached The set fire level is reached during fire mode.
Remote data transmission The remote data transmission connection to the centre has been interrupted.
error
Movement block The “Movement block input” input is active.
Abort movement The lift halts at the next level due to an exceptional situation (e.g. "External control off",...).(Not
displayed when lift is moving to a destination).
Moving to level: {No.} A job is being completed normally. The next destination is displayed. (Displayed only when
moving to a destination).
Fire brigade mode ext. The lift is requested at the set fire brigade level.
Fire brigade mode int. The lift only handles movement jobs via lift car call entry.
BLOCKED due to Because of a serious error, the lift cannot be operated further.
{reason}
Inspection mode Inspection mode is on.
PTC resistor active Overheating of the drive mechanism is reported.
Card error A missing or faulty card has been detected.
Check level reached Arrival at the check level is reported. Movement to the check level is only started if the "Control &
light off" input is set.
Correction movement Because of missing or incorrect floor information, the lift is making a correction movement to a
final stop.
Photoelectric barrier While the doors are closing, the photoelectric barrier is blocked.
blocked
LRV contact inactive The supervisory contact of the control card has been triggered.
Modem error A modem operation error has occurred. See note in error memory.
Re-adjustment Re-adjustment is active.
Emergency down Because of a serious error, the hydraulic lift is moving to the set level where it will be switched
off.
Emergency limit switch The emergency top limit switch contact has been triggered (monitored only in hydraulic lifts). The
passive safety circuit has been interrupted.
Emergency halt actuated The emergency halt has been actuated.
No level status The control system does not currently have any valid floor information. It will make a correction
movement before handling the next job.
Park level reached This indicates arrival at the selected park level.
Park movement The lift is moving to the park level.
Park time running The set park time has started.
Passive safety circuit The passive safety circuit has been interrupted.
Rest level reached This reports that the rest level has been reached. The lift only moves to the rest level when the
"Control & light off" input is set.
Return mode Return mode is switched on.
Contactor monitoring The main contactor monitoring has been triggered.
Safety circuit The control voltage of the safety circuit has been interrupted.
Safety circuit The safety circuit has been triggered.

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 21 of 31


Ethan Frome
Kurzanleitung

Operating status

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 22 of 31


Ethan Frome
Kurzanleitung

Operating status Explanation


Voltage monitoring The processor voltage monitoring has been triggered.
Control voltage The safety circuit’s control voltage is missing.
Control & light off Normal movement operation has been halted and the lift has been sent to the rest level.
Close doors The lift is waiting for the doors to close before departing.
Overload The load measuring device in the lift car reports that the lift loading capacity has been exceeded.
Full load The load measuring device in the lift car reports that the lift loading capacity has been reached.
Foyer surveillance active The triggering of foyer surveillance is indicated.
Priority movement internal The lift is handling an internal priority call.
Waiting for internal call After the emergency stop button has been actuated or the safety photoelectric barrier has been
broken, the lift waits for an internal call to allow it to start.
Maintenance: Doors shut The "Maintenance: Doors shut" setting is active. No other door controls are permitted.
Winter circuit The winter circuit is active, and winter movements are currently being carried out.
Random calls The random call program is activated.
Forced door close A forced door close has been carried out.

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 23 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 24 of 31


Ethan Frome
Kurzanleitung

8 Test Adapter Function Set-up


The test adapter function shows you the signals of the MPK 40 inputs and outputs in the menu. The menu option is found
under “Information / Test adapter".
E x a m p . B S T 4 0 -I/O In p u ts A d r . 0 0 A u sg än g e A d r. 04
V o lta g e M o n ito r in g M o to r C o n tro l
A: 00 V o lta g e m o n ito r in g .
B it 0 T e r m in a l 2 0 1 B it 0 C o n tro l K31
In p u t: * * * * * * 6 7 B
B
it
it
1
2
T e r m in a l 2 0 0
T e r . 2 0 5 ( M o t. s ig .)
B
B
it
it
1
2
C o n tro l
C o n tro l
K32
K33
A: 04 M o to r C o n tro l B
B
it
it
3
4
T e r . 2 1 0 ( C a lls & O u t)
v o lt a g e t e s t
B
B
it
it
3
4
C o n tro l
C o n tro l
K34
K35
B it 5 PTC B it 5 C o n tro l v 1 /2
O u tp u t: 0 * * 3 4 5 6 7 B it 6 in te rn a l u s e B it 6 in t e r n a l use
B it 7 in te rn a l u s e B it 7 in te r n a l use

* = S ig n a l a c tiv e

E x a m p . N e t-I/O F K F 4 0 FK F 40 FKF 40
C o n n e c tio n 1 - 8 C o n n e c tio n 1 7 - 2 4
FKF ID : 1 C C C C C C C C B it 0 C ar c a ll 1 B it 0 n .c .
IO (1 - 8 ): * 0 * 0 * 0 0 0 B
B
it
it
1
2
C
C
ar
ar
c a ll
c a ll
2
3
B
B
it
it
1
2
n .c .
n .c .
B it 3 C ar c a ll 4 B it 3 n .c .
FKF ID : 1 I I I I I I I I B it 4 C ar c a ll 5 B it 4 Im p u ls / L e v e l u p
B it 5 C ar c a ll 6 B it 5 Im p u ls / L e v e l d o w n
IO (1 7 -2 4 ): - - - - * * 0 * B
B
it
it
6
7
C
C
ar
ar
c a ll
c a ll
7
8
B
B
it
it
6
7
C o r r e c tio n T o p
C o r r e c tio n B o tto m

* = S ig . a c tiv e , 0 = S ig . n o t a c tiv e , - = C o n n e c tio n w /o fu n c t. C o n n e c tio n ty p e : I = In p u t, O = O u tp u t, C = C a ll ( I/O )

S e le c t F ie ld s (A d r e s s , I/O , B it)

+ -
S e le c t A d r e s s ,I/O , B it

O K
S e t o u tp u t B it

E.g. BST 40 I/O Inputs addr. 00 Outputs addr. 04


Voltage monitoring Motor control
A:00 Voltage monitoring
Bit 0 Terminal 201 Bit 0 Control K31
Input: * * * * * * 6 7 Bit 1 Terminal 200
Bit 2 Ter. 205 (motor signals)
Bit 1 Control K32
Bit 2 Control K33
Bit 3 Ter. 210 (calls & outp.) Bit 3 Control K34
A: 04 Motor control Bit 4 External voltage test
Bit 5 PTC
Bit 4 Control K35
Bit 5 Control v1/2

Output: 0 * * 3 4 5 6 7 Bit 6 Internal use


Bit 7 Internal use
Bit 6 Internal use
Bit 7 Internal use
* = Signal set
E.g. Network I/O FKF 40 FKF 40 FKF 40
Connection 1 - 8 Connection 17 – 24
FKF ID: 1 C C C C C C C C
Bit 0 Internal call 1 Bit 0 n.c.
IO (1 – 8): * 0 * 0 * 0 0 0 Bit 1 Internal call 2
Bit 2 Internal call 3
Bit 1 n.c.
Bit 2 n.c.
Bit 3 Internal call 4 Bit 3 n.c.
FKF ID: I I I I I I I I Bit 4 Internal call 5
Bit 5 Internal call 6
Bit 4 Pulse / flush up
Bit 5 Pulse / flush down

IO (17-24): - - - - * * 0 * Bit 6 Internal call 7


Bit 7 Internal call 8
Bit 6 Correction up
Bit 7 Correction down
* = signal set, 0 = signal not set, = = connection without Fkt. Connection type: I = input, O = output, C = call (in / out)

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 25 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 26 of 31


Ethan Frome
Kurzanleitung

Address set-up, BST


Input Output
Addr. Bit Voltage monitoring not used
00 0 Monitoring: Terminal 201
1 Monitoring: Terminal 200
2 Monitoring: Motor signals
3 Monitoring: Terminal 207 (calls)
4 Monitoring: FST
5 PTC
6 Internal use
7 Internal use
Addr. Bit Safety circuit not used
01 0 U1
1 U2
2 U3
3 U4
4 U5
5 U6
6 Internal use
7 Internal use

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 27 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 28 of 31


Ethan Frome
Kurzanleitung

Address set-up, BST (continuation)


Input Output
Addr. Bit Freely assignable inputs Freely assignable outputs
02 0 E1 / Contact monitoring** A1 / Re-set / Delay*
1 E2 / Safety circuit* A2 / Control & light off*
2 E3 / Zone safety circuit* A3 / Bridge S10*
3 E4 / Return control On* A4 / General fault*
4 E5 / Return control Up* A5 / Busy light*
5 E6 / Return control Down* A6 / Out of order*
6 E7 / Lift cage light Control off* A7 / Incident message, doors*
7 E8 / Light voltage* A8 / PTC resistor message*
Addr. Bit External calls 1-8 External calls 1-8
03 0 R1 R1
1 R2 R2
2 R3 R3
3 R4 R4
4 R5 R5
5 R6 R6
6 R7 R7
7 R8 R8
Addr. Bit Switch Motor drive
04 0 Switch, external control (S35) Drive K31 (Up)
1 Internal use Drive K32 (Down)
2 Internal use Drive K33
3 Internal use Drive K34
4 Internal use Drive K35 (valve control / FBA)
5 Internal use Drive v ½
6 Internal use Internal use
7 Internal use Internal use
* Default set-up ** Hard programmed

In addition, via the menu display, you can set the output signals individually. Please
note that this manual setting can produce non-defined switching statuses in the control
system.

9 Input Field, Test Calls


The menu option shows the current calls. Using the keys shown, you can make calls.

C a lls D o o r S id e 1 +- S e le c t C a ll ty p e
C a lls F lo o r 1 - 7 L a n d . c a ll d o w n
Door 1: I I C a r c a ll
2 1 2 3 4 5 6 7
+ -
a c t. F lo o r &
D ir e c t io n
O K
= s e t c a ll = s e le c ts flo o r

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 29 of 31


Ethan Frome
Kurzanleitung

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 30 of 31


Ethan Frome
Kurzanleitung

Freely Assignable Terminals (BST 40 / Network)


Using these menu options, you can link the freely available functions with the freely assignable terminals
on the BST 40 or the FKF 40 module in the network.

B a s ic S e tt in g s B a s ic S e tt in g s
M P K - C o n tro l M P K - C o n tro l
B S T - In p u t s B S T - O u tp u ts
O K O K

B a s ic S e tt in g s +_ B a s ic S e t tin g s +_

B S T - In p u ts B S T - O u tp u ts
C o n tr o l & L ig h t o ff D o o r e rro r m e s s a g e
In p . T e r m in a l: E 7 O u tp . T e r m in a l: A 3
BST

C o n tr o l o f th e F u n c tio n
B a s ic S e ttin g s

B S T - In p u ts

C o n tr o l & L ig h t o ff
O K

In p . T e r m in a l: E7 + -

B a s ic S e t tin g s B a s ic S e ttin g s
M P K - C o n tro l M P K - C o n tro l
N e t - In p u t s N e t-O u tp u ts
O K O K

N e t-In p u ts +_ N e t-O u tp u ts +_

P r e L im itB o tto m O u t o f S e r v ic e
FKF ID :1 E 1 (I) FKF ID :1 A 5 (O )

C o n tr o l o f th e fu n c tio n
Net

N e t-In p u ts

P r e -L im it b o tto m
O K ESC

+ -
FKF ID : 1 O K
E 1 (I)

+ - -
F l.: D o o r:+

11. July 2020 Ó KOLLMORGEN Steuerungstechnik Cologne Page 31 of 31