NOTES:

ARAMCO.
Provide TIE-IN ID 1. ALL DIMENSIONS ARE IN MILLIMETER UNLESS
1 2 3 4 5 6 7A 7 7B 8 9 10 11 12 13.A 13 13.B 14 15 16 17 18 19 20 21 22 23 24 match with infra OTHERWISE INDICATED.
network

SAUDI
12000 12000 12000 12000 12000 12580 12530 12000 12000 12000 12000 12530 12380 12000 12000 12000 12000 12000 12000 12000 12000 12000 12000 2. ALL PIPE SIZES SHOWN IN DRAWING ARE NOMINAL
DIAMETER.
H 3. ALL STUB-OUTS SHALL BE FINISED BETWEEN
A

0.3m TO 0.5m ABOVE FFL WITH CAPPED/FLANGED


KK

OF
CONNECTION TO AVOID ENTRY OF DIRT/FOREIGN
MA

N 3044174030
F2 MATERIAL.

CONSENT
E 328154700 4. ALL FIREFIGHTING WORKS SHALL BE VERIFIED BY
Provide TIE-IN ID F REGISTERED FIRE FIGHTING CONTRACTOR AS PER
match with infra ACTUAL SITE CONDITION.
network TAPPING FROM FIRE TAPPING FROM FIRE
F1 5. THIS DRAWING IS INTENDED FOR GROUND FLOOR
WATER NETWORK. WATER NETWORK. BELOW GRADE SLAB CONSTRUCTION ONLY.

WRITTEN
FOR CONTINUATION, FOR CONTINUATION, 6. THIS DRWAING IS EXTRACTED FROM MODEL
SEE DRAWING RA-635803-001 SEE DRAWING RA-635803-001 MYDP-7WW-D204-M3-F-000001.
7. REFER, GENERAL NOTES (FIRE PROTECTION)

40000
N 3044184010

N
E 327904700 DRAWING RA-620026-001.
8. REFER, STANDARD DETAIL FIRE DRAWING

THE
RA-620694-001,002,003 AND 004.
9. INTERNAL SPRINKLER INSIDE PRE-FAB CABINS
E4

WITHOUT
WILL BE SCOPE OF PRE-FAB VENDORS.

E3
LEGEND:-
E

DRAWING
E2 2-WAY FIRE
DEPARTMENT INLET
E1 FF FIRE FIGHTING PIPE

THIS
STAND PIPE
REFER TO DRAWING No.:620620 SH-002

39500
REFER TO DRAWING No.:620620 SH-003
FIRE HOSE CABINET

FROM
IV
D4 ISOLATION VALVE

OBTAINED
D3 FE-1
4.5KG DRY CHEMICAL PORTABLE FIRE
EXTINGUISHER CLASS ABC TYPE

D FE-2 4.5 KG CO2 PORTABLE FIRE EXTINGUISHER

D2 ZCV ZONE CONTROL VALVE

BE
D1 ACV ALARAM CONTROL VALVE

SHALL
41300

PART,
C4

IN
C3

OR
C

FULL,
C2

IN
C1

31050

REPRODUCTION
REFER TO DRAWING No.:620620 SH-004 REFER TO DRAWING No.:620620 SH-005
B2 REFERENCE DRAWINGS
DRAWING LIST RA-610540-050
FIRE WATER NETWORK RA-635803-001,003
B

B1

NO
ARAMCO.
29500
KEYPLAN

A2

SAUDI
THIS BUILDING

OF
A1

PROPERTY
SOLE
A GROUND FLOOR FIRE PROTECTION (SH-1)
SCALE 1 : 500

THE
N
CRITERIA FOR THE HYDRAULIC

ARE
SCHEDULE FOR PORTABLE EXTINGUISHER
DESIGN OF THE SPRINKLER SYSTEM SR DESIG DESCRIPTION CAPACIT QTY. APPROVAL
0 10 20 30.0 40.0 50.0

HEREIN
THIS BUILDING IS PROTECTED BY A HYDRAULICALLY METERS SCALE: 1:500
PRESSURIZED ABC
DESIGNED AUTOMATIC SPRINKLER SYSTEM. FE-1 ABC 4.5 KG 53
MULTIPURPOSE DRY UL LISTED.
CHEMICAL FM APPROVED
LOCATION OF THE HYDRAULICALLY MOST SCALE: 1:500

CONTAINED
OFFICES EXTINGUISHER
DEMANDING AREA
PRESSURIZED
DESIGN STANDARD FE-2 CO2 4.5 KG 57 UL LISTED. REVISION VALIDATION
NFPA 13 CARBON DIOXIDE
EXTINGUISHER FM APPROVED THIS REVISION NO. E IS COVERED, FOR ALL APPROVAL AND CERTIFICATION
CRITERIA FOR THE HYDRAULIC DESIGN OF THE STANDPIPE SYSTEM SPRINKLER K-FACTOR REQUIREMENTS, PER SAEP-334, UNDER DRAWING COMPLETION CERTIFICATE NO:
K80 " Area of the Sprinkler operation in hydraulically remote area " shall be shown in the Layout drawings . Calculated area,
SPRINKLER THERMAL SENSITIVITY STANDARD RESPONSE POTASSIUM 25-00053-0007-222
TYPE OF SYSTEM STANDPIPE-CLASS III distance between sprinklers, No of sprinkler selected in branch line shall be marked in the remote area of sprinkler

INFORMATION
operation as per NFPA 13 . FE-3
This comments BICARBONATE
BC will be typical 4.5 table
for all hydraulic calculation KG - UL LISTED.
SPRINKLER COVERAGE (STANDARD/EXTENDED) 20 SQ.M DESIGN CERTIFICATION REVIEW FOR KEY DRAWINGS OTHER
PURPLE K FM APPROVED (DESIGN AGENCY) REQUIRED (SAUDI ARAMCO)
DESIGEN STANDRAD NEPA 14 SPRINKLER TEMPERATURE RATING INTERMEDIATE(79-107 DEGREE ENGG./DATE CERTIFIED BY/DATE CONST. AGENCY/DATE OPERATIONS/DATE BY/DATE

CELSIUS) - UL LISTED. RVS/BAM UFA


FE-4 ABF WET CHEMICAL 6 LTRS. 04/09/2020 04/09/2020
FM APPROVED
CALCULATION METHOD HYDRAULICALLY MOST REMOTE AREA REV.NO. DATE REVISION DESCRIPTION
INSTALLTION ORIENTATION SEE LEGEND AND PLANS
E 04/09/2020 ISSUED FOR APPROVAL
TOTAL FLOW REQUIRED AT THE MOST 250 GPM (946 l/min) TYPE OF SYSTEM WET
JOB ORDER/EWO NO.

THE
REMOTE FIRE HOSE CABINET (FHC) LIGHT
THIS REVISION IS NOT TO BE USED FOR
OCCUPANCY CLASSIFICATION
(AS PER NFPA 14TOTAL FLOW OF 1250 25-00053-0007 CONSTRUCTION UNTIL CERTIFIED AND DATED

GPM CONSIDERED FOR CALCULATION) DESIGN DENSITY 4.1 L/MIN


SAUDI ARABIAN OIL COMPANY

AND
PIPE SCHEDULE (UG/AG) DRAWING TYPE
MIN PRESSURE REQUIRED AT THE MOST 6.9 BAR AREA HYDRAULICALLY MOST DEMANDING AREA 139 SQM GR FLOOR FIRE PROTECTION (SH-1)
SERVICES COMPONENT MATERIALS STANDARDS
FPS
REMOTE FIRE HOSE CABINET (FHC)

DRAWING
# OF HYDRAULICALLY MOST DEMANDING 07 NOS. JACK UP LEG SHOP (204)
PIPES GROUP-B ASTM A53 ASTM A106/
SPRINKLERS 0.5 BAR FIRE FIGHTING
CALCULATED FLOW AT TIE-IN POINT 4739.3 l/min MINIMUM RESIDUAL PRESSURE AT THE REMOTEST BLACK STEEL API 5L rating Sch. 40 RIGS, PLATFORM AND UTILITIES
SPRINKLER DESIGN FLOW 574 L/MIN
CALCULATED PRESSURE AT TIE-IN POINT 8.39 BAR
FITTINGS ASME B16.5 ASME B16.9 & ASMEB16.5 RAS AL KHAIR SAUDI ARABIA
COMBINED HOSE STREAM ALLOWANCE 379 L/MIN
UNIT NO. PLANT NO. INDEX DRAWING NUMBER SHT. NO. REV. NO.

THIS
AREA PROTECTED BY EACH SYSTEM RISER < 4800 SQM
D204 964 B RA-620620 001 E
Saudi Aramco 2615 ENG. (05/05)