Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

HSSE ALERT (2016 – 0065)

(SECL_HSSE #013)
Fall through the grating opening

□ Summary and Causes of Incident

When scaffolder
prepared installation of temporary pipe
support on the pipe rack, he lost his
balance and fell to the ground (7m)
through the grating opening (1m*0.7m)

Direct cause In-direct cause Root cause

* No Grating opening cover * Grating Opening procedure was * Omitted safety work process
after installation of pipe omitted - It takes time to discuss
- Missing the opening cover - Grating Open Checklist was not interface work, due to the
and hand rail used (cold work permit only) work restriction of
※ Grating Removal was not subcontractor (Covid-19)
* The IP didn’t hook his lanyard mentioned on the permit
* The work is not recognized by * There is no proper
SECL construction & safety team communication Channel for
* S-PCM was performed, but the brown field work activities
safety measures for grating - Use the client’s work permit.
removal were not reviewed well ※ There is no Grating removal
permit from client
by construction SI.
- The training for grating opening - There is no review process for
and S-PCM were not conducted. the client’s permit by SECL SI

□ Preventive Measures

▶ Access Safety alert : CUBE KM→ Knowledge → Browse by category → Business Management → HSE
HSSE ALERT (SECL_HSSE #014)
(2016 – 0065)
Finger caught-in between Girder and Web-Splice

□ Overview and Cause

▷ Date : 2020. 06. 05(Fri) 15:58

▷ Description
While worker was trying to hold the position of web splice on the bolting point, the second
worker was holding web splice which is attached to a rope. The worker who was positioning
web splice for bolting was holding web splice with hands, resulting in pinching finger in
between girder and web splice due to poor communication among holding and positioning
workers(Web Splice : 0.4*1.4M, 3T, 75Kg)

There can be play / space if the bolt


tightening is not performed thoroughly

Normally this activity is carried out using ropes and hand tools Sample Picture

Direct Case) In-Direct Cause Root-Cause

• During installation of steel girder, • When assembling from the top the • During Web Splice assembly
finger was caught between bolt is not sufficiently tightened. while performing bolting and
girder and web splice. The nuts were no tightened activity, if the bolt is not
enough and posed gap. sufficiently tightened , there can
• Web splice was directly being be a gap and a pinch position /
hold by hand. Position of • Hand Injury caused due to wrong space is formed.
holding in web splice was type of gloves and wrong position
wrong. of hand at pinch point.

□ Preventive Measures
- Thoroughly tighten the web splice to the girders from the ground so that there is no play / space
between the girders and the web splice.
- The bolt position shall be kept inwards to achieve further tightening if there is play
- Adjustment of Web Splice shall be carried out by using attached ropes NOT directly by hands.
- Worker holding the web splice and adjusting girder both shall have better communication
- Wear the right type of gloves to prevent hand injuries.