Professional Documents
Culture Documents
FSMF PDF
FSMF PDF
FSMF PDF
5.4.1 Benefits
End-user benefits
This feature does not affect the end-user experience.
Operator benefits
The FSMF is a successor of the FSMD and FSME System Modules providing enhanced
capacity, connectivity and expansion possibilities in the same form factor. FSMF is IP
ingress protected and operates at the temperature range from -35 to + 55 °C.
5.4.2 Requirements
Software requirements
Table Software requirements lists software required for this feature.
Capacity FSMF
GSM/EDGE 72
[transceivers]
WCDMA 528
[channel elements]
HSDPA 756
[Mbps]
HSUPA 115
[Mbps]
LTE DL 450
[Mbps]
LTE UL 150
[Mbps]
LTE BW/cell 20
[MHz]
LTE cells 3
[cell count]
MIMO (HSPA/LTE) yes
One FSMF System Module provides a hardware baseband capacity for up to three 20
MHz LTE cells.
Figure 29 presents the front view of the Flexi Multiradio BTS System Module FSMF.
Figure 29 Front panel of the System Module (FSMF) with optional sub-modules
FPFD, FTIF, and two FBBAs
Interfaces
The FSMF provides the following interfaces:
• Three optical OBSAI RP3-01 interfaces with up to 6 GBit/s or CPRI
• One optical interface which can be used as OBSAI RP3-01 interface with up to 6
Gbit/s (or CPRI) or as 1000Base-X as network interface
• One electrical interface 100/1000Base-T as transport backhaul interface
• One electrical interface 10/100Base-T as local management interface
• One Sync In interface
• One Sync Out interface
• One EAC (External Alarm and Control) interface (6 alarm signals, 6 SW-controllable
signals that can be assigned to be either Alarm or Control signals). The interface
includes also a CAN interface.
• One SRIO (Serial Rapid Input/Output) interface for an external baseband extension,
for example additional System Module
• Two baseband extension interfaces for optional sub-modules
• One -48 VDC input and one -48 VDC output
More information, see Flexi Multiradio 10 BTS, Multiradio System Module Description.
Impacts on interfaces
New interfaces available.
Alarms
There are no alarms related to this feature.
Parameters
There are no parameters related to this feature.
5.5.1 Benefits
End-user benefits
This feature does not affect the end-user experience.
Operator benefits
Outdoor Power distribution unit with fuses is integrated into the 3U high System Module
casing. The FPFD is installed into the Flexi Multiradio System Module and requires
therefore no dedicated power distribution unit thus no need for additional space or
cabinet.
5.5.2 Requirements
Software requirements
Table Software requirements lists software required for this feature.
Hardware requirements
This feature requires Flexi Multiradio 10 BTS.
The FPFD has integrated basic Over Voltage Protection on input (OVP Type approval
level with +/- 1 kV (L-L) 8/20 µs and +/- 2 kV (L-N) 8/20 µs), EMC filtering and reverse
polarity protection. It protects the connected units against short circuit, overcurrent (fixed
trip points), and high voltage transients.
Interfaces
The FPFD provides the following external interfaces:
• One -48 V DC input
• Four external -48 V DC outputs
• One internal DC output to the System Module
• Control panel with the following elements:
– one LED for each output (RF1, RF2, RF3, EXT, SYS)
– SELECT and SET buttons to control their status
Communication with Flexi Multiradio System Module is done via serial interface.
Impacts on interfaces
New interfaces available.
Alarms
There are no alarms related to this feature.
Parameters
There are no parameters related to this feature.
5.6.1 Benefits
End-user benefits
This feature does not affect the end-user experience.
Operator benefits
The general-purpose FPFC can be flexibly used at larger outdoor and indoor Flexi BTS
sites, or up on a tower, together with Radio Modules or RRHs. It provides six -48V DC
outputs with improved Over Voltage Protection (OVP).
5.6.2 Requirements
Software requirements
Table Software requirements lists software required for this feature.
Hardware requirements
This feature requires no new or additional hardware.
To provide more than six outputs, it is possible to chain two FPFCs using the same DC
power source.
Interfaces
FPFC provides the following external interfaces:
• one DC input
• six DC outputs
– CH1-2: maximum fixed output 30A
– CH3-6: maximum adjustable output 4A/15A/30A
Additionally, each output has On/Off bar.
• one EAC connector
EAC connector (RJ45) informs about any abnormal situation, for example, when the
protective component(s) have been damaged. It indicates SPD alarm via two alarm
signals - Normal Open (NO) and Normal Closed (NC):
– NO
Alarm is active when the connection is closed. 5V alarm detection line is pulled
down during alarm: Active = 0, Inactive = 1.
– NC
Alarm is active when the connection is open. 5V alarm detection line is pulled up
during alarm: Active = 1, Inactive = 0.
Impacts on interfaces
New interfaces available.
Alarms
There are no alarms related to this feature.
Parameters
There are no parameters related to this feature.