LOGIQTM P9

Make it simple. Make it your own.


Product Specification

Personalized
Customized settings and workflow that help you improve ease of use

Patient-Centric
Solutions that enable improved focus on patients and help enhance your confidence and care delivery

Practical
Smart ergonomics and solutions to help improve your productivity and investment value
Product Description General Specifications - Height: 810-910 mm
The LOGIQ P9 is a highly capable - Rotation: +/- 30°
ultrasound system that provides Dimensions and Weight • Digital TGC and Digital A/N keyboard
excellent image quality and productivity • Backlit alphanumeric keyboard(Option),
through easy to use tools across a wide • Height 16 mm spacing
range of applications in a portable, Fixed Monitor Arm (Standard) • Ergonomic hard key layout
ergonomic, budget-friendly system - Maximum: 1475 mm (60.0 in)
design. • Interactive back-lighting
- Minimum: 1375 mm (54.1 in) • Integrated recording keys for remote
Articulating Monitor Arm (Option) control of up to 8 peripheral devices or
System Architecture - Maximum: 1570 mm (61.8 in) DICOM® devices
P-Agile Architecture – Agile architecture - Minimum: 1320 mm (52.0 in)
is GE’s innovative, patented, model- • Width
based technology provides vast - Keyboard: 430 mm (16.9 in) Touch Screen
computational power, ease of imaging, - Foot Cover: 495 mm (19.5 in) • 10.4” wide LCD, High Resolution, Color,
workflow flexibility and product upgrade- Touch screen
- Monitor: 525 mm (20.7 in)
ability. It has been migrated to LOGIQ P9
• Depth • Interactive dynamic software menu
as P-Agile architecture. The LOGIQ P9
excels in the following areas: - Foot Cover: 685 mm (27.0 in) • Brightness adjustment
- Rear Handle: 740 mm (29.1 in) • User-configurable layout
Personalized - Customized settings and • Weight (without peripherals)
workflow that help you improve ease of Monitor
- 60 kg/ 132 lbs
use • 21.5” wide screen LCD with high
Electrical Power resolution
• Voltage: 100-240 Vac • Tilt/Rotate/Translate
Patient-Centric - Solutions that enable • Frequency: 50/60 Hz - Tilt angle +15°/-90°
improved focus on patients and help - Rotate angle +/-90°
• Power consumption maximum of 500
enhance your confidence and care
VA with peripherals - Translate horizontal 660mm
delivery
• Maximum Thermal Output: 700 BTU/hr. - Translate vertical 150mm
• Fold-down and lock mechanism for
Practical - Smart ergonomics and Console Design transportation
solutions to help improve your • 3 Active Probe Ports • Brightness and contrast adjustment
productivity and investment value • 4 Active Probe Ports(Option) • Horizontal/Vertical viewing angle of +/-
• 1 CW Pencil Probe Port 178°
• Integrated HDD (Capacity: 500GB) • Articulating monitor arm(Option)
• Integrated DVD+/-R/W Multi Drive
• On-board Storage for System Overview
- B/W-printer
Applications
• Integrated speakers
• Abdominal
• Wheels:
• Obstetrical
- Wheel diameter: 125 mm • Gynecological
- Locking mechanism that provides • Breast
rolling lock and caster swivel lock • Small parts and superficial
• Probe holders, removable for cleaning • Musculoskeletal
and washing • Vascular
• Gel Holder with integrated Gel • Urological
Warmer(Option), Removable for • Endocavitary
Cleaning and Washing - Transvaginal
• Integrated cable management - Transrectal
• Easily removable air filters • Pediatric and Neonatal
• Front and rear handles(Option) • Transcranial
• Cardiac
• Intraoperative
User Interface
Operator Keyboard Scanning Methods
• Operating keyboard adjustable in two • Electronic Sector
dimensions: • Electronic Convex
• Electronic Micro Convex

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 2


• Electronic Linear • Easy 3D • ECG IEC Cable
• Real Time 4D Volume Sweep • Anatomical M-Mode • CW Doppler
• Patient Information Database • SW DVR
Transducer Types • Image Archive on CD/DVD and Hard - Storage: CD/DVD Media
• Sector Phased Array Drive - Storage: USB Memory Stick
• Convex Array • Easy Backup to Media for Data • Real Time 4D
• Microconvex Array Security • 4D TUI
• Linear Array • TruAccess, Raw Data Processing and • Static 3D Color
• Matrix Array Analysis • Volume Review
• Single CW (Pencil) Probes • Real-time Automatic Doppler Calcs • VOCAL
• Volume Probes (4D) • OB Calcs • VCI Static
• Fetal Trending • High Cabinet
Operating Modes • Multi Gestational Calcs • Drawer
• B-Mode • Hip Dysplasia Calcs • Side Tray
• Coded Harmonic Imaging • Gynecological Calcs • Small Probe Adaptor
• M-Mode • Vascular Calcs • Vertical Endocavitary Probe Holder
• Color Flow Mode (CFM) • Cardiac Calcs • Probe Cable Hanger
• Power Doppler Imaging (PDI) with • Urological Calcs • Cable Hook Rear
directional map • Renal Calcs • Card Reader Mounting Kit
• PW Doppler with High PRF • InSiteTM ExC Capability, Remote • Paper Tray
• M-Color Flow Mode Service • OPIO Tray
• Anatomical M-Mode • iLinq Capability, Remote Service • Gel warmer
• Anatomical M-Color Mode • On-board electronic documentation • Multipurpose holder
(PDF format) • Physical A/N Keyboard
• B-FlowTM/B-Flow Color Mode (option)
• MPEGVue
• Extended Field of View (LOGIQ View,
Option) • Key Macro Peripheral Options
• B Steer + (option) • Network Storage  Integrated Mounting Kits and Remote
Coded Contrast Imaging2 (option) • Quick Save
• Controls provided for
• CW Doppler Mode (option) • Quick Patient Entry
- B/W Digital thermal printer
• Tissue Velocity Imaging (TVI) Mode • TIC Motion Tracking
• Digital Color A6 thermal printer
(option) • My Page
• Digital Color A5 thermal printer
• Elastography (option) • My Trainer
• External USB printer connection
• SW DVR (option) • Reset
• Wireless LAN card for wireless data
• 3D/4D Volume Modes : transfer
- 3D Static (option) System Options
• HDMI output available for compatible
- 4D Realtime (option) • Auto IMT devices
• AutoEF • Foot Switch, with programmable
System Standard Features • Elastography functionality, 3-Pedal
• Hard Disk Partition of 358GB for • Elastography Quantification1 • Console Protective Cover
image storage without Compression • Advanced 3D with 3D Landscape • Universal Video Converter
• Storage Formats • DICOM 3.0 Connectivity • Power Assistant(Battery Pack)
- DICOM: compressed/uncompressed, • LOGIQ View • Isolation transformer
single/multi-frame, with/without raw • B-Flow/B-Flow Color • S-Video
data • CF/PDI Quantification • Composite output
- Export JPEG, WMV (MPEG 4), and AVI • Coded Contrast Imaging2 • EMI Filter
formats • Measure Assist Breast
• Advanced user interface with high • Measure Assist OB Display Modes
resolution 10.4 inch wide LCD touch • Breast Productivity Package • Live and Stored Display Format: Full
panel • Thyroid Productivity Package size and split screen - both w/
• Automatic Optimization • B Steer+ thumbnails. For Still and CINE
-Auto Tissue optimization • Stress Echo • Review Image Format: 4x4, and
-Auto Spectral Optimization • Tissue Velocity Imaging (TVI) with "thumbnails". For Still and CINE
-Auto TGC Q-Analysis • Simultaneous Capability
• CrossXBeamTM compounding • Scan Assistant - B/PW
• Speckle Reduction Imaging (SRI-HD) • Compare Assistant - B/CFM or PDI
• Fine Angle Steer • Report Writer - B/M
• Coded Harmonic Imaging • ECG - B + CFM/M
• Virtual Convex • ECG AHA Cable - Real-time Triplex Mode

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 3


(B + CFM or PDI/PW or CW) • Gestational Age from - TIC: Thermal Index Cranial (Bone)
- B-Flow + PW LMP/EDD/GA/BBT - TIB: Thermal Index Bone
- Dual B (B/B) • Probe Name - MI: Mechanical Index
• Selectable Alternating Modes • Map names • % of Power output
- B/M • Probe Orientation • Biopsy Guide Line and/or Zone
- B/PW • Depth Scale Marker • Heart Rate
- B + CFM/M • Lateral Scale Marker
- B + CFM (PDI)/PW(CW) General System Parameters
• Focal Zone Markers
- B-Flow + PW
• Image Depth
- 3D – Mode
- 3D – Mode Color • Zoom Depth System Setup
- B/CW • B-Mode • 8 Pre-programmable Categories
- B + CFM (PDI)/CW - Gain • User Programmable Preset Capability
• Multi-image Split Screen (quad - Dynamic Range • Factory Default Preset Data
screen) - Imaging Frequency • Languages: English, French, German,
- Live and/or frozen - Edge Enhance Spanish, Italian, Portuguese, Russian,
- B + B/CFM or PDI - Frame Averaging Greek, Swedish, Danish, Dutch,
- PW/M - Gray Map Finnish, Norwegian, Japanese
- ATO On/Off
• Independent CINE playback • OB Report Format: 5 Types, Tokyo
- SRI-HD Univ., Osaka Univ., USA, Europe, and
• Zoom: Write/Read/Pan
- CrossXBeam
• Colorized Image ASUM
• M-Mode
- Colorized B • EFBW: 10 Types, Japan, USA and
- Gain
- Colorized M Europe (Tokyo Uni., Osaka Univ.,
- Dynamic Range
- Colorized PW Tokyo Shinozuka, JSUM, German,
- Time Scale Shepard, Merz, Hadlock/Shepard,
- Colorized CW
- Colorized B-Flow • Doppler Mode Williams, Brenner)
- Gain
• Time line Display • Pre-defined Annotations and User
- Angle
• Independent Dual B/PW Display Programmable Libraries/Annotations
- Sample Volume Depth and Width
• CW • Body Patterns
- Wall Filter
• Display Formats: • Customized Comment Home Position
- Velocity and/or Frequency Scale
- Top/Bottom selectable - Spectrum Inversion
format (Size: 1/2:1/2; 1/3:2/3; - Time Scale Complete User Manual available on
2/3:1/3) - PRF board through Help (F1)
- Side/Side selectable format - Doppler Frequency User Manual and Service Manual are
(Size: 1/2:1/2; 1/3:2/3; 0:1) • Color Flow Mode included on CD with each system. A
Switchable after Freeze - Line Density printed Manual is available upon request .
• Timeline only - Frame Averaging
• Virtual Convex - Packet Size CINE Memory/Image Memory
• CrossXBeam - Color Scale: 3 types
• CINE Memory: 776MB
• Tissue Velocity Imaging (TVI) Mode - Power
• Selectable CINE Sequence for CINE
• Elastography and simultaneous - Directional PDI
B/Elasto Review
- Symmetrical Velocity Imaging
• Prospective CINE Mark
- Color Velocity Range and Baseline
- Color Threshold Marker • Measurements/Calculations &
Display Annotation
- Color Gain Annotations on CINE Playback
• Patient Name: First, Last & Middle
- PDI • Scrolling Timeline Memory
name each store 27 characters. Up to
- Color Scale Inversion • Cine Capture Function
64 total characters displayed.
- Color Doppler Frequency • Digital Continuous Cine Capture
• Patient ID: 31 characters. Up to 27
characters displayed. • TGC Curve • Dual Image CINE Display
• 2nd Patient ID • Acoustic Frame Rate • Quad Image CINE Display
• Age, Sex and Date of Birth • Cine Gage, Image Number /Frame • CINE Gauge and CINE Image Number
Number Display
• Hospital Name: 23 characters
• DVR Counter and Status • CINE Review Loop
• Date format: 3 Types selectable
- MM/DD/YY • Body Pattern: Multiple human and • CINE Review Speed: 10 Steps (11, 13,
- DD/MM/YY animal types 14, 17, 22, 25, 31, 100, 200, 400%)
- YY/MM/DD • Application Name
• Time format: 2 types selectable • Measurement Results Image Storage
- 24 hours, • Operator Message • On-board database of patient
- 12 hours • Displayed Acoustic Output information from past exams
- TIS: Thermal Index Soft Tissue • Storage Formats:

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 4


- DICOM: compressed/ uncompressed, • Adjustable ECG Gain Control
single /multi-frame, with/ without • Automatic Heart Rate Display Digital M-Mode
Raw Data • Gain: –20 -20 dB, 1 dB step
- Export JPEG, JPEG2000, WMV (MPEG Scanning Parameters • Compression: 0.5 – 2.4, 13steps
4), and AVI Formats • Sweep Speed: 0 – 7, 8 steps
• Digital P-Agile Beamformer
• DICOM Still Image Storage Size: Architecture • Frame Averaging
~2.1MB • 386,469 System Processing Channels • Gray Scale Map: 7Types
• Gray Image: ~1.3 to ~3.5 MB • Max. Frame Rate up to 2399 F/s • MColorization: 9 Types
• Color Image: ~1.8 to ~5.0 MB • Displayed Imaging Depth: 0 – 33 cm • Frequency
• Display Format: Full Size, 4x4 and • Minimum Depth of Field: 0 - 1 cm • Line Density
“thumbnails” (Zoom, probe dependent) • Scanning Size (FOV or Angle –
• Storage Devices: • Maximum Depth of Field: 0 - 33 cm depending on Probe, see Probe
- Internal Hard Drive Partition of 358 (probe dependent) specifications)
GB for Image Storage • Transmission Focus: 1 – 8 Focal Points • Rejection: 6 Steps
- External USB 2.0 Hard Drive Support selectable (Probe and Application • M/PW Display Format: V-1/3B, V-1/2B,
for Import, Export, DICOM Read, dependent) V-2/3B, H-1/2B, H-1/4B, Timeline only
SaveAs and MPEGVue • Quad Beamforming
- USB Memory Stick Support for SaveAs • Continuous Dynamic Receive Focus / Anatomical M-Mode
and MPEGVue (64MB to 4GB) Aperture • M-mode cursor adjustable at any plane
- CD+/-RW storage: 700MB • Multi-Frequency / Wideband • Can be activated from a CINE loop,
- DVD storage: +/-R (4.7GB) Technology from a live or stored image
• Conversion to Formats: JPEG, AVI, • Frequency Range: 2 to 18 MHz • M & A capability
WMV • 256 Shades of Gray • Available with Color Flow Mode
• Live Image and stored Image side-by- • 270 dB of Composite Dynamic Range • Curved Anatomical M-Mode
side Display • Adjustable Dynamic Range
• Compare old images with current • Adjustable Field Of View (FOV) Digital Spectral Doppler Mode
exam • Up to 132 degree (depending on • Adjustable:
• Reload of archived date sets Probe)Image Reverse: Right/Left - Acoustic Power
• Network Storage support for Import, • Image Rotation: 2 Steps of 0°, 180° - Gain
Export, DICOM Read, SaveAs, - Dynamic Range
MPEGVue Digital B-Mode - Gray Scale Map
• Acoustic Power Output: 0 – 100%, 25 - Transmit Frequency
Connectivity & DICOM steps - Wall Filter
• Ethernet network connection • Gain: from 0 – 90 dB, 1 dB Steps - PW colorization
• DICOM 3.0 (option) • Dynamic Range: 36 - 96 dB, 16Steps - Velocity Scale Range
- Verify • Frame Averaging: 8 Steps - Sweep Speed
- Print • Gray Scale Map: 7Types - Sample Volume Length
- Store • Tint Map: 9 Types - Angle Correction
- Modality Worklist • Frequency: Up to 5 selectable - Steered Linear
- Storage Commitment (depending on Probe) - Spectrum Inversion
- Modality Performed Procedure Step - Trace Method
• Speed of Sound (probe, application
(MPPS) - Baseline Shift
dependent)
- Media Exchange - Doppler Auto Trace
• Line Density: 5 Steps
- Off network / mobile storage queue - Time Resolution
• Line Density Zoom: 5 Steps
- Query / Retrieve - Compression
• Thermal Index: TIC, TIS, TIB
- Structured Reporting - Trace Direction
• Image Reverse: On/Off
- Public SR Template - Trace Sensitivity
• Focus Number: 8 Steps
-Structured Reporting – compatible • Focus Width: 3 Types
with vascular and OB standard • Suppression: 6 Steps Digital Color Flow Mode
-Direct Export DICOM SR and XML • Edge Enhance: 7 Steps • Base Line: 0 – 100%, 11 Steps
- Media Store of SR • Rejection: 6 Steps • Invert: On/Off
- InSite ExC capability • Steered Linear: +/- 12° • CF/PDI Focus Depth: default pre-
• Wireless LAN (Option) • Scanning Size (FOV or Angle – settable for10 – 100% of ROI in
depending on the probe) depth, 6Steps
Physiological Input Panel • SRI-HD: Up to 6 Levels selectable • CF/PDI Flash Suppression: 5 Steps
• Physiological Input • CrossXBeam: Up to 9 Angles selectable • CF/PDI Angle Steer: 0, +/- 20°
• ECG, 2 lead • Depth: 1- 33cm, 1cm Step, Probe • Packet Size:8-24, dependent on
• Dual R Trigger dependent Probe and Application
• Pre-settable ECG R Delay Time • Line Density: 5 Steps
• Re-settable ECG Position • Line Density Zoom: 5 Steps

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 5


• Frame Average: 7 Steps • SV Gate: 1, 2, 3, 4, 5, 6, 7, 8, 10, 12, 14,
• PRF: 0.1-23.5kHz/20 steps 16mm B-Flow/B-Flow color
• Spatial Filter: 6 Steps • Angel Correct: +/- 90°, 1° Step • Available on 9L-RS, 12L-RS, ML6-15-RS,
• Gain: 0 – 40dB, 0.5dB Steps • Spectral Color: 6Types L8-18i-RS probes
• Wall Filter: 4 Steps, dependent on • PW Sweep Speed: 8 Steps • Background: On/Off
Probe and Application • Invert: On/Off • Sensitivity/PRI: 17steps
• Scanning Size (FOV or Angle): Probe • M/PW Display Format: V-1/3B, V-1/2B,
• Line Density: 5steps
dependent V-2/3B, H-1/2B, H-1/4B, Timeline only
• Edge Enhance: 7steps
• Duplex: On/Off (PW only)
• CF/PDI Vertical Size (mm) of ROI: • Frame Average: 8 steps
• PW/CF Ratio: 1, 2, 4
default pre-settable • Gray Scale Map: 8 types
• Gain: 0 – 85dB, 1dB Steps
• CF/PDI Center Depth (mm) of ROI: • Tint Map: 9 types
• Wall Filter: 5.5 –5000Hz, 27 Steps,
default pre-settable • Dynamic Range: 36 – 96 dB,
dependent on Probe and Application
• CF/PDI Frequency: Up to 5, • PW Angle Steer: 0, +/-10, 15, 20° 16steps
depending on Probe • PRF: 0.5 – 26.7 kHz with PW, 0.4 –49.0 • Rejection: 6 steps
• Color Maps, including velocity- kHz with CW • Gain: 0 – 90 dB, 1 dB step
variance maps: 20 Types depending • Sample Volume Depth: 30Steps default • Dual Beam: On/Off pre-settable
on Application pre-settable • B-Flow Color: 8 color maps and 6
• Transparent: 5 Steps • CW-Mode is available on the following directional maps
• Color Threshold: 0 – 100%, 11Steps Probes: • Accumulation: 8 steps
• Arbitration Threshold: 15 Steps pre- - 3Sc-RS
settable 6S-RS
- Coded Contrast Imaging
• Auto Line Density: On/Off pre- - P8D • Available on C1-5-RS probe
settable • Steerable CW Mode includes • Modes: General, Resolution and
• PW/CF Ratio: 1, 2, 4 • Transmit Frequency Penetration
• Accumulation: 8 Steps • CW Colorization • Tissue Background Selection: 4 steps
• Quantification • Velocity Scale Range • Display Tissue Image and Contrast
• Spectrum Inversion enhanced Image simultaneously in split
• Trace Method screen
Digital Power Doppler Imaging
• Doppler Auto Trace • 2 separate Contrast Timers
• PDI Map: 16Types
• Trace Direction • Timed Updates: 0.05 – 10 seconds
• CF/PDI Focus Depth: default pre-
• Trace Sensitivity • Accumulation mode: 8 steps
settable for 10 – 100% of ROI in Depth,
6Steps • Max Enhancement Mode: On/Off
• CF/PDI Acoustic Output: 0 – 100%, 10%
Automatic Optimization • Gray Scale Map: 21 types
Steps • Optimize B-Mode, B-Flow image to • Colorization: On/Off
• CF/PDI Angle Steer: 0, +/- 20° improve contrast resolution. Selectable • Time Trigger Scan: 0.3 & 0.5 – 10 sec.,
• Packet Size: 8 –24, dependent on Probe amount of contrast resolution 0.5 sec step
and Application improvement (low, medium, high) • Flash / Burst mode
• Spatial Filter: 6 Steps • Auto TGC • Time Intensity Curve (TIC) Analysis
• Frame Average: 7 Steps • Auto-Spectral Optimize adj • The LOGIQ P9 is designed for
• PRF: 0.1-23.5kHz/20 steps - Baseline compatibility with commercially
• Power Threshold: 0 – 100%, 11 Steps - Invert available ultrasound contrast agents.
• Arbitration Threshold: 15 Steps pre- - PRF (on live image) Because the availability of these agents
settable - Angle correction is subject to government regulation
• Gain: 0 – 40dB, 0.5dB Steps and approval, product features
• Wall Filter: 4Steps depending on Probe Coded Harmonic Imaging intended for use with these agents may
and Application • Available on all imaging probes not be commercially marketed nor
• CF/PDI Frequency: Up to 5 Steps, • Line Density: 5Steps made available before the contrast
depending on Probe • Line Density Zoom:5 Steps agent is cleared for use. Contrast
• Auto Line Density: On/Off pre-settable • Suppression: 6 Steps related product features are enabled
• Transparent: 5 Steps • Edge Enhance: 7Steps only on systems for delivery to an
• Invert: On/Off • Gray Scale Map: 7types authorized country or region of use. 2
• Accumulation: 8 Steps • Tint Map: 9 types
• Flash Suppression • Gain: 0 – 90 dB, 1 dB step LOGIQ View
PW/CW Wave Doppler • Dynamic Range: 36 – 96 dB, 16step • Extended Field of View Imaging
• Velocity Scale: • Rejection: 6 step • Available on all imaging probes
- Max. 10.34m/s • Frequency: Up to 4 steps, probe • For use in B-Mode
- Min. 0.06m/s depended • CrossXBeam is available on linear
• Gray Scale Map: 8Types probes
• Base Line: 5 – 95%, 11 Steps • Auto detection of scan direction
• Pre or post-process zoom up to 10x

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 6


• Rotation • Steps include image annotations, mode according to same projection on
• Auto best fit on monitor transitions, basic imaging controls and previous level
• Measurements in B-Mode measurement initiation
• Up to 60cm scan length Virtual Convex
Report Writer • Provides a convex field of view
Easy 3D (available on all imaging probes) • On-board reporting package • Compatible with CrossXBeam
• Colorize Image automates report writing • Available on all linear and sector
• Threshold (Opacity) • Formats various exam results into a transducers: 9L-RS, 12L-RS, ML6-15-RS,
• Render report suitable for printing or L8-18i-RS, 3Sc-RS, 6S-RS Probes
• Texture reviewing on a standard PC
• Gray Surface • Exam results include patient info, SRI-HD
• Scalpel exam info, measurements, • High Definition Speckle Reduction
• Auto Movie calculations, images, comments and Imaging
• Undo diagnosis • Provides multiple (6) levels of speckle
• Reset • Standard templates provided reduction
• Allows unlimited rotation and planar • Customizable templates • Compatible with Side by Side DualView
translation Display
• 3D reconstruction from CINE sweep • Compatible with ALL Linear, convex
Elastography
• Available on C1-5-RS, ML6-15-RS, 9L-RS, and sector transducers
Advanced 3D (available on all imaging • Compatible w/ B-Mode, Color, Contrast
12L-RS Probes
probes) Agent and 3D/4D imaging
• E Index: 8 maximum
• Acquisition of Color data • Pre and post processing
• E Ratio: 7 maximum
• Automatic rendering
• 3D Landscape technology CrossXBeam
• 3D Movie TVI
• Provides 3, 5, 7 or 9 angles of spatial
• Main Mode • Myocardial Doppler Imaging with color
overlay on tissue image compounding
• Live Side by Side DualView Display
Real Time 4D • Available on all sector probes
• Compatible with
• Acquisition Modes: • Tissue color overlay can be removed to
show just the 2D image, still retaining - Color Mode
- Realtime 4D mode - PW
- Static 3D mode the tissue velocity information
- SRI-HD
• Visualization Modes: • Curved Anatomical M-mode: free
(curved) drawing of M-mode generated - Coded Harmonic Imaging
- 3D Rendering (diverse surface and - Virtual Convex on Linear Probes
intensity projection modes) from the cursor independent from the
axial plane • Available on C1-5-RS, 8C-RS, E8C-RS,
- Sectional Planes (3 Section planes 9L-RS, 12L-RS, ML6-15-RS, L8-18i-RS,
perpendicular to each other) • Q-Analysis: Multiple Time -Motion trace
display from selected points in the RAB2-6-RS Probes
- Volume contrast Imaging-Static
- Tomographic ultrasound Imaging myocardium
Controls Available While “Live”
• Render Mode: • Write Zoom
- Surface texture, Surface Smooth, Stress Echo • B/M/CrossXBeam-Mode
max-, min- and X-ray (average • Advanced and flexible stress-echo - Gain
intensity projection), Mix Mode of two examination capabilities - TGC
render Modes • Provides exercise and pharmacological - Dynamic Range
• Curved 3point Render start protocol templates - Acoustic Output
• 3D Movie • 8 default templates - Transmission Focus Position
• Scalpel: 3D Cut tool • Template editor for user configuration - Transmission Focus Number
• Display Format: of existing templates or creating new - Line Density Control
- Quad: A-/B-/C-Plane/3D templates - Sweep Speed for M-Mode
- Dual: A-Plane/3D • Reference scan display during - Number of Angles for CrossXBeam
- Single: 3D or A- or B- or C-Plane acquisition for stress level comparison • PW-Mode
Automated Volume Calculation (dual screen) - Gain
– VOCAL II (optional) • Baseline level / previous level - Dynamic Range
Scan Assistant selectable - Acoustic Output
• Workflow enhancement tool for • Raw data continuous capture - Transmission Frequency
standardized and repetitive exams -Over 180 sec available - PRF
• Include Factory Programs • Wall motion scoring (bulls-eye and - Wall Filter
• User – defined programs and Import segmental) - Spectral Averaging
Functionality • Smart stress: Automatically set up - Sample Volume Gate
various scanning parameters (e.g. - Length
geometry, frequency, gain, etc.) - Depth

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 7


- Velocity Scale Measurements / Calculations - HC (Head Circumference)
• Color Flow-Mode - APTD x TTD (Anterior/Posterior Trunk
- CFM Gain Diameter by Transverse Trunk
General B-Mode
- CFM Velocity Range Diameter)
• Depth & Distance
- Acoustic Output - LV (Length of Vertebra)
• Circumference (Ellipse / Trace)
- Wall Echo Filter - FTA (Fetal Trunk Cross-sectional Area)
• Area (Ellipse / Trace)
- Packet Size - HL (Humerus Length)
• Volume (Ellipsoid)
- Frame Rate Control - BD (Binocular Distance)
• % Stenosis (Area or Diameter)
- CFM Spatial Filter - FT (Foot Length)
• Angle between two lines
- CFM Frame Averaging - OFD (Occipital Frontal Diameter)
- CFM Line Resolution - TAD (Transverse Abdominal Diameter)
- Frequency / Velocity Base Line Shift General M-Mode - TCD (Transverse Cerebellum
• M-Depth Diameter)
Controls Available on “Freeze” or • Distance - THD (Thorax Transverse Diameter)
Recall • Time - TIB (Tibia Length)
• Slope - ULNA (Ulna Length)
• Automatic Optimization
• Heart Rate • Estimated Fetal Weight (EFW) by:
• SRI-HD
• CrossXBeam – Display non- - AC, BPD
compounded and compounded image General Doppler - AC, BPD, FL
simultaneously in split screen Measurements/Calculations - AC, BPD, FL, HC
• 3D reconstruction from a stored CINE • Velocity - AC, FL
loop • Time - AC, FL, HC
• B/M/CrossXBeam-Mode • A/B Ratio (Velocities / Frequency Ratio) - AC, HC
- Gray Map Optimization • PS (Peak Systole) - BPD, APTD, TTD, FL
- TGC • ED (End Diastole) - BPD, APTD, TTD, SL
- Colorized B and M • PS/ED Ratio • Calculations and Ratios
- Frame Average (loops only) • ED/PS Ratio - FL/BPD
- Dynamic Range • AT (Acceleration Time) - FL/AC
• Anatomical M Mode • ACC (Acceleration) - FL/HC
• Max Read Zoom to 8x • TAMAX (Time Averaged Maximum - HC/AC
• Base Line Shift Velocity) - CI (Cephalic Index)
• Sweep Speed • Volume Flow (TAMEAN and Vessel Area) - AFI (Amniotic Fluid Index)
• PW-Mode • Heart Rate - CTAR (Cardio-Thoracic Area Ratio)
- Gray Map • PI (Pulsatility Index) • Measurements / Calculations by: ASUM,
- Post Gain • RI (Resistivity Index) ASUM 2001, Berkowitz, Bertagnoli,
- Baseline shift Brenner, Campbell, CFEF, Chitty, Eik-
- Sweep Speed Real-time Doppler Auto Nes, Ericksen, Goldstein, Hadlock,
- Invert Spectral wave form Measurements / Calculations Hansmann, Hellman, Hill, Hohler,
- Compression Jeanty, JSUM, Kurtz, Mayden, Mercer,
• PS (Peak Systole)
- Rejection Merz, Moore, Nelson, Osaka Univ., Paris,
• ED (End Diastole)
- Colorized Spectrum Rempen, Robinson, Shepard,
• MD (Minimum Diastole)
- Display Format Shepard/Warsoff, Tokyo Univ.,
• PI (Pulsatility Index)
- Doppler Audio Tokyo/Shinozuka, Yarkoni
• RI (Resistivity Index)
- Angle Correct • Fetal Graphical Trending
• AT (Acceleration Time)
- Quick Angle Correct • Growth Percentiles
• ACC (Acceleration)
- Auto Angle Correct • Multi-Gestational Calculations (4)
• PS/ED Ratio
• Color Flow-Mode • Fetal Qualitative Description
• ED/PS Ratio
- Overall Gain (loops and stills) (Anatomical survey)
• HR (Heart Rate)
- Color Map • Fetal Environmental Description
• TAMAX (Time Averaged Maximum
- Transparency Map (Biophysical profile)
Velocity)
- Frame Averaging (loops only) • Programmable OB Tables
• PVAL (Peak Velocity Value)
- Flash Suppression • Over 20 selectable OB Calcs
• Volume Flow (TAMEAN and Vessel Area)
- CFM Display Threshold • Expanded Worksheets
- Spectral Invert for Color/Doppler OB Measurements/Calculations
• Anatomical M-Mode on cine loop GYN Measurements/Calculations
• Gestational Age by:
• 4D • Right Ovary Length, Width, Height
- GS (Gestational Sac)
- Gray Map, Colorize • Left Ovary Length, Width, Height
- CRL (Crown Rump Length)
- Post Gain • Uterus Length, Width, Height
- FL (Femur Length)
- Change display – single, dual, quad • Cervix Length, Trace
- BPD (Biparietal Diameter)
sectional or rendered • Ovarian Volume
- AC (Abdominal Circumference)
• ENDO (Endometrial thickness)

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 8


• Ovarian RI • Physical Foot Print: 50.4 x 6 mm
• Uterine RI Probes • B-Mode Frequency: 9, 11, 13, 15 MHz
• Follicular measurements • Harmonic Frequency: 8, 10, 12, 15 MHz
• Summary Reports C1-5-RS, 8C-RS, E8C-RS, ML6-15-RS, 12L-RS, • Doppler Frequency: 5, 6.3, 8.3 MHz
• Biopsy Guide: Multi-Angle, disposable
9L-RS, L8-18i-RS, 3Sc-RS, 6S-RS, RAB2-6-RS,
Vascular with a reusable bracket (H40432LJ)
and P8D
Measurements/Calculations
• SYS DCCA (Systolic Distal Common C1-5-RS Convex Probe 12L-RS Linear Probe
Carotid Artery) • Applications: Abdomen, Vascular, • Applications: Small Parts, Vascular,
• DIAS DCCA (Diastolic Distal Common OB/GYN, Urology Pediatric, Neonatal, Musculoskeletal
Carotid Artery) • Probe Band Width: 1.75-4.95 MHz • Probe Band Width: 3.85–11.65 MHz
• SYS MCCA (Systolic Mid Common • Number of Element: 192 • Number of Element: 192
Carotid Artery) • Convex Radius: 55 mmR • FoV (Max): 38.4 mm
• DIAS MCCA (Diastolic Mid Common • FoV (Max): 70° • Physical Foot Print: 38.4 x 4 mm
Carotid Artery) • Physical Foot Print: 67 x 11.5 mm • B-Mode Frequency: 7, 9, 11 MHz
• SYS PCCA (Systolic Proximal Common • B-Mode Frequency: 2, 3, 4 MHz • Harmonic Frequency: 9, 11, 12 MHz
Carotid Artery) • Harmonic Frequency: 3, 4, 5 MHz • Doppler Frequency: 4.2, 5, 6.3, 8.3 MHz
• DIAS PCCA (Diastolic Proximal Common • Doppler Frequency: 1.9, 2.1, 2.5, 3.6 • Biopsy Guide: Multi-Angle, disposable
Carotid Artery) MHz with a reusable bracket (H40432LC)
• SYS DICA (Systolic Distal Internal • Biopsy Guide: Multi-Angle, disposable
Carotid Artery) with a reusable bracket (40432LE) 9L-RS Linear Probe
• DIAS DICA (Systolic Distal Internal • Applications: Vascular, Small Parts,
Carotid Artery) Pediatric, Abdomen
• SYS MICA (Systolic Mid Internal Carotid 8C-RS Micro Convex Probe • Probe Band Width: 2.7–7.8 MHz
Artery) • Applications: Neonatal, Pediatrics • Number of Element: 192
• DIAS MICA (Diastolic Mid Internal • Probe Band Width: 3.6-10.0 MHz • FoV (Max): 44.2 mm
Carotid Artery) • Number of Element: 128 • Physical Foot Print: 44.2 x 6 mm
• SYS PICA (Systolic Proximal Internal • Convex Radius: 10.7 mmR • B-Mode Frequency: 5, 7, 9 MHz
Carotid Artery) • FoV (Max): 132° • Harmonic Frequency: 8, 9, 10 MHz
• DIAS PICA (Diastolic Proximal Internal • Physical Foot Print: 24.7 x 5 mm • Doppler Frequency: 3.1, 3.6, 4.2, 5 MHz
Carotid Artery) • Biopsy Guide: Multi-Angle, disposable
• B-Mode Imaging Frequency: 6.0. 7.0.
• SYS DECA (Systolic Distal External with a reusable bracket (H4906BK)
8.0 MHz
Carotid Artery) • Harmonic Frequency: 8.0, 9.0, 10.0 MHz
• DIAS DECA (Diastolic Distal External L8-18i-RS Linear Probe
• Doppler Frequency: 3.6, 4.2, 5.0, 6.3
Carotid Artery) • Applications: Small Parts, Vascular,
MHz
• SYS PECA (Systolic Proximal External Pediatric, Neonatal
• Biospsy Guide available: None • Probe Band Width: 4.5-14.0 MHz
Carotid Artery)
• DIAS PECA (Diastolic Proximal External • Number of Element: 168
E8C-RS Endo Micro Convex Probe • FoV (Max): 25.2 mm
Carotid Artery) • Applications: OB/GYN, Urology,
• VERT (Systolic Vertebral Velocity) • Physical Foot Print: 25.2 x 4 mm
Transvaginal, Transrectal • B-Mode Frequency: 8, 9, 12, 15, 18 MHz
• SUBCLAV (Systolic Subclavian Velocity) • Probe Band Width: 3.6-10.0 MHz
• Auto IMT • Harmonic Frequency: 9, 15, 18 MHz
• Number of Element: 128 • Doppler Frequency: 5, 6.3, 8.3 MHz
• Summary Reports
• Convex Radius: 10.7 mmR • Biopsy Guide available: None
• FoV (Max): 132°
Urological • Physical Foot Print: 24.7 x 5 mm 3Sc-RS Phased Array Sector Probe
Measurements/Calculations • B-Mode Frequency: 6, 7, 8 MHz • Applications: Cardiac, Transcranial,
• Bladder Volume • Harmonic Frequency: 8, 9, 10 MHz Abdomen
• Prostate Volume • Doppler Frequency: 3.6, 4.2, 5.0, 6.3 • Probe Band Width: 1.45–4.2 MHz
• Lt/Rt Renal Volume MHz • Number of Element: 64
• Generic Volume • FoV (Max): 120°
• Biopsy Guide: Single Angle, disposable
• Post-Void Bladder Volume • Physical Foot Print: 15 x 14 mm
with a disposable bracket (E8385MJ,
E8333JB), Single-Angle, Reusable • B-Mode Frequency: 2, 3, 4 MHz
Cardiac bracket (H40412LN) • Harmonic Frequency: 3, 3.5, 4.0, 5.0
MHz
Measurements/Calculations
ML6-15-RS Matrix Array Linear Probe • Doppler Frequency: 1.7, 2.1, 2.5, 3.1, 3.6
• Cardiac calculation package including
• Applications: Small Parts, Vascular, MHz
extensive measurements and display of
Pediatric, Neonatal, Musculoskeletal • Biopsy Guide: Multi-Angle, Reusable
multiple repeated measurements
• Probe Band Width: 4.3–13.0 MHz bracket (H46222LC)
• Parameter annotation follow ASE
standard • Number of Element: >1000
• FoV (Max): 50.4 mm 6S-RS Phased Array Sector Probe

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 9


• Applications: Cardiac Neonatal, compatibility GE Medical Systems Ultrasound & Primary Care
Diagnostics, LLC, a General Electric company, doing
Pediatrics - IEC 60601-1-4 Software Design life business as GE Healthcare.
• Probe Band Width: 2.2-7.0 MHz
cycle GE Healthcare
• Number of Element: 64 9900 Innovation Drive
- IEC/EN 62034 Programmable
• FoV (Max): 90° Wauwatosa, WI 53226
• Physical Foot Print: 10.2 x 5.5 mm Electrical Medical Systems U.S.A.
• B-Mode Frequency: 4, 5, 6.5, 8.0 MHz - IEC 60601-1-6 Collateral Standard: www.gehealthcare.com

• Harmonic Frequency: 4.8, 5.4, 6.2 MHz Usability


• Doppler Frequency: 2.8, 3.1, 3.6, 4.2, 5.0 - IEC/EN 62366 Application of Usability
MHz engineering to medical devices
• Biopsy Guide available: None - IEC/EN 60601-2-18 Particular
RAB2-6-RS Convex Volume Probe requirements for safety of endoscopic
• Applications: Abdomen, OB/GYN, equipment
Urology - IEC/EN 60601-2-37 Particular
• Probe Band Width: 1.7-4.8 MHz requirements for the safety of
• Number of Element: 128 ultrasonic medical diagnostic and
• Convex Radius: 47 mmR monitoring equipment
• FoV (Max): 66°, Volume Angle: 85° - IEC 61157 Declaration of acoustic
• Physical Foot Print: 53.8 x 13 mm
output
• B-Mode Frequency: 3, 4, 5 MHz
• Harmonic Frequency: 4, 5, 6 MHz - ISO 10993 Biological evaluation of
• Doppler Frequency: 1.9, 2.5, 3.1, 3.6 medical devices
MHz - NEMA UD2 Acoustic output
• Biopsy Guide: Multi-Angle, disposal with measurement standard for diagnostic
reusable bracket (H48681ML) ultrasound equipment
- NEMA UD3 Acoustic output display
P8D CW Split Crystal Probe
(MI, TIS, TIB, TIC)
• Applications: Cardiac, Vascular
 EMC Emissions Group 1 Class B device
requirements as per Sub clause 4.2 of
Inputs and Outputs CISPR 11
 HDMI Out - 6S-RS: EMC Emissions Group 1
Class A device
 Ethernet Network (RJ45)
 External Audio Out
 USB (2x in front, 3x in rear, 2x monitor)
1. Elastography with semi-Quantification
 AC Power Input (Elastography Quantification) described in
 Probe connectors this material has not been cleared by the
Safety Conformance U.S. FDA and is not available for
promotion or sale in the United States.
2. Coded contrast imaging described in this
The LOGIQ P9 is: material has not been cleared by the U.S.
FDA and is not available for promotion or
 Listed to UL 60601-1 by a Nationally sale in the United States.
Recognized Test Lab
 Certified to CSA 22.2,60601.1 by an
SCC accredited Test Lab © 2015 General Electric Company – All rights
 CB-Test report by National Certification reserved.
Body General Electric Company reserves the right to make
 CE Marked to Council Directive changes in specifications and features shown herein,
93/42/EEC on Medical Devices or discontinue the product described at any time
without notice or obligation. Contact your GE
 Conforms to the following standards Representative for the most current information.
for safety:
GE and GE monogram are trademarks of General
- IEC/EN 60601-1 Medical Electrical Electric Company or one of its subsidiaries
equipment, General requirement for LOGIQ, B-Flow, InSite and CrossXBeam are
Safety trademarks of General Electric Company.
- IEC/EN 60601-1-1 Safety DICOM is the registered trademark of the National
Electrical Manufacturers Association for its
requirements for Medical Electrical standards publications relating to digital
Systems communications of medical information.
- IEC/EN 60601-1-2 Electromagnetic

LOGIQ P9 Product Specification DOC1676338 March 2015 Page 10