PAGE(12)

CLEAN OUT DOOR CALCULATION


Clean Out Door Size 36 in x 48 in
1 )- Claculations of shell reinforced plate
As per clause 5.7.7.4 required cross -section area of the reinforcement
Over the top of the opening
Acs <=K1*h*t/2 10692
where
Acs =cross-sectional area of the reinforcement over the top of the opening ,in mm^2
k1= area of coefficient from fig. 1.08
h =Vertical height of Clear Opening ,in mm 900 mm
b=horizontal width of clear opening ,in mm 1200 mm
t= Calc. thickness of the lowst shell course exclusive of any corr. allowance. 22.00 mm
computing for vertical axis in fig. 271,269
(H+8.8)D+71.5 123 t
1.408 h * 4.9D (H-0.3 = 0.8
Where
H= Max.design liquid level 17 m
D= Nominal tank diameter 46 m
G=sp. gravity not less than 1.00
Unite scale horiz.=0.004
Therefore
Value of K1 from FIG .5-11 = 1.08
Min.Cross -Sectional area ,Acs 10692 mm^2
as per clause 3.7.7.5 max .height of reinforcement ,1.5h =
1350 mm
Dimension of reinforcing plate (RF) Provided
Ap =tpx(L-h) 25%
Wtp=thickness of RF plate = 22.00 mm
L=hieght of RF Plate = 1400 mm
h=height of clear opening = 900 mm
11000 mm^2 safe area
Calculation of bottom reinforcing plate
As per clause 5.7.7.6 required min.thickness of bottom reinforcing plate
tb =( h^2/360000)+( b/170)*sqrt(HG) 31.2 mm
Provide thickness 32.0 mm

Clean Out Door Weight 5,200 kg