Ultrasonic Flow Sensor Specification

www.pztceramics.com violet.shan@pztceramics.com
Ultrasonic Flow Sensor Parameter

Parameter Value Notes


Storage temperature Ts -30 … + 100⁰C
Operating pressure P >3.0Mpa
Testing pressure Pt >5.0Mpa 18h
Resonant Frequency Fr 960 kHz Approx.
Anti-resonant frequency Fa 1200kHz Approx.
Operating frequency F 1000khz
Resonance Impedance Za <100Ω
Impedance at operating < 20% 0 … 100⁰C
frequency change over
temperature
Impedance (at operating 10% 25⁰C
frequency) matching
within a batch
Capacitance C 1200pF ± 20% 25⁰C
Acceptance sensitivity dB >35dB 0 … 100⁰C
Sending and receiving mv >0.6mv
ratio
After-shock Bus <10Bus R < 0.1
Sealing method Epoxy potting

Electrical specification:
type JDRC-14002 Resonant <100Ω Sensitivity >35db
impedance
capacitance 1200PF±10% Center 960KHz±10KHz Return radio >0.6mv
frequency
Aftershock <10Bus Work 0°C-95°C Sealing Epoxy resin
temperature method potting
Pressure >3.0MPa Degree of IP68 Lead position Sensor center
resistance protection

Note: All materials comply with the requirements of environmental protection, while
Piezoelectric ceramic exempt from lead restriction.

www.pztceramics.com violet.shan@pztceramics.com
Package:
PCS/CTN Packing plate Packing box Gross weight Net weight
(cm) (cm) ( Kg ) ( Kg )
500 32.5×30×3.5 34×32×26 6.3 5.6

Note:
1.Storage Condition:-25°C~11°C.
2.Please take Anti interference into consideration when designing driving circuit.
3.Driving voltage is suggested to be lower than 5Vpp.
4.Operating temperature:0°C~+95°C.
5.Maximum pressure endurance is 3.0MPa.