BANER LIFESPACES LLP BILL OF QUANTITY WEST PORT

BOQ OF PROJECT : WEST PORT AT BANER, PUNE


RATE AMOUNT REMARKS
Sr.NO. ITEM DESCRIPTION UNITS QUANTITY
(Rs.) (Rs.)
BOQ FOR PODIUM PARKING FAÇADE (PART-3)
Design Wind Pressure (KPA) 1.3
Proof Load at 1.5 times of Design Wind Pressure (KPA) 1.95

A FR GRADE ACP CLADDING SYSTEM PODIUM PARKING LEVEL WT-04

Design, Fabrication, Installation, Protection, Cleaning and Handover of ACP Cladding comprises of 4mm Thk.
Aluminium composite panels (ACP) FR Grade cladding system of approved shade & make fixed on to the
Extruded aluminium section framing (Horizontal Band) mechanically fixed on to the designed MS/RCC structure
with the help of SS 304 grade screws & Material Separator all in line with Tender Drawing. Fabricated
A.1 Sq.mtr. 534.00
Aluminium composite panels (ACP) with grooving and bending along with corner cleats are mechanically fixed to
the aluminium framing using extruded aluminium cleats and stainless steel 304 grade screws. The
vertical/horizontal joints are to be sealed with weather silicone (DC 991) of approved make. as shown in the
drawing which will prevent water to enter inside the Cladding.

Quote rate include Aluminium Composite Panel shall be of approved makes & made out of 4mm thk. Aluminium
composite panel comprising of Aluminium Skin of Min. 0.5mm (Alloy Grade AA3105) with KYNAR 500/Hylar
5000 PVDF based fluorocarbon / FEVE Lumiflon paint based fluro-polymer resin/Exterior Grade Lead free
Coating on Top Face Compliance to AAMA 2605 of approved finish + 3mm thk. noncombustible mineral based
polymer core compliance to Class "0" As per BS 476 & 2 hrs Fire Resistance as per ASTM E119 & NBC Guidlines
2016 + 0.5mm aluminium skin with service coat on Bottom face. Overall weight of the ACP shall not be less
than 7.0 kg per sq.mtr. Shade as approved by Client / Architect. 0.8mm Thk continuous G.I Flashing to be fitted
below the ACP at Top face cladding AS shown in the tender Drawing.

A.2 4MM THICK. ACP SHEET FOR PODIUM PARKING LEVEL COPPING - FR GRADE
Quote rate include Aluminium Composite Panel shall be of approved makes & made out of 4mm thk. Aluminium
composite panel comprising of Aluminium Skin of Min. 0.5mm (Alloy Grade AA3105) with KYNAR 500/Hylar
5000 PVDF based fluorocarbon / FEVE Lumiflon paint based fluro-polymer resin/Exterior Grade Lead free
Coating on Top Face Compliance to AAMA 2605 of approved finish + 3mm thk. noncombustible mineral based Sq.mtr. 534.00
polymer core compliance to Class "0" As per BS 476 & 2 hrs Fire Resistance as per ASTM E119 & NBC Guidlines
2016 + 0.5mm aluminium skin with service coat on Bottom face. Overall weight of the ACP shall not be less
than 7.0 kg per sq.mtr. Shade as approved by Client / Architect.

B FR GRADE ACP CLADDING AT PODIUM PARKING LEVEL VERTICAL BAND PATTERN, Wall Type -05

Fabrication, Installation, Protection, Cleaning & Handover of ACP Cladding System comprises of 4mm Thk. FR
Grade 4mm thick. Cladding of approved color Finish & Coating of approved by Client / Architect make
including all necessary frame work all in line with Tendre Drawing.The ACP Panel shall be Supported on
Aluminum Tube thickness 2mm Framing with Aluminum Cleat, the System shall be Hold by hot dip Galvanized
B.1 Sq.mtr. 1,100.00
up to 80 micron thick M.S. brackets with Grade 316 SS Fasteners, SS bolts and nuts complete with all other
necessary accessories. The Bracket support shall be designed to accommodate 3 Dimensional movement for
achieving perfect verticality and proper fixing of ACP Cladding. 8MM Bison board to be fitted behind the ACP
cladding using Aluminium L angle with SS Screw with silione as shown in the Tender drawing.

The system shall be designed to withstand a wind pressure of 1.3 KPa as per IS 875 part 3 at all levels,
elevations and heights.
The extruded aluminium sections shall be of 6063 T6 alloy or BSH9 Conforming to IS- 63400.

The fastening materials like Nuts, Bolts, Screws, Rivets, washers, clamps, straps etc along with all consumables
and accessories required for fixing the FR Grade ACP cladding system shall be of stainless steel 316 grade and
corrosion resistant of approved make as per architects/Consultants Specification.
Exterior perimeter sealants (DC 991) & Backer Rod at the junctions of adjacent materials to the ACP cladding.

The quote rate shall include all Scaffolding and statutory obligations and safety code compliance as per client.
B.2 4MM THIK. ACP SHEET - FR GRADE FOR VERTICAL BAND PATTERN CLADDING AT PODIUM LEVEL
Quote rate include Aluminium Composite Panel shall be of approved makes & made out of 4mm thk. Aluminium
composite panel comprising of Aluminium Skin of Min. 0.5mm (Alloy Grade AA3105) with KYNAR 500/Hylar
5000 PVDF based fluorocarbon / FEVE Lumiflon paint based fluro-polymer resin/Exterior Grade Lead free
Coating on Top Face Compliance to AAMA 2605 of approved finish + 3mm thk. noncombustible mineral based Sq.mtr. 1100.00
polymer core compliance to Class "0" As per BS 476 & 2 hrs Fire Resistance as per ASTM E119 & NBC Guidlines
2016 + 0.5mm aluminium skin with service coat on Bottom face. Overall weight of the ACP shall not be less
than 7.0 kg per sq.mtr. Shade as approved by Client / Architect.

C ALUMINUM HORIZONTAL BOX LOUVERS AT PODIUM PARKING LEVEL Wall Type - WT-06

Design, Fabrication, Installation, Protection, Cleaning and Handover of Aluminium Horizontal Box Louvers of
(50mm x 25mm x 2mm thk.) fixed with Aluminum Flate Bar using SS Screw with equal c/c spaced fixed. Louver
Profile shall be fixed on Continuous vertial Aluminium Box pipe (100mmX50mmX2mm thik.) with the help of
MS Bracket (HDG 75 to 80 micron) all in line with the Tender Drawing. The System shall be with stand wind
pressure of 1.3 Kpa confirming to IS 875 Part-lll. MS bracket shall be fix to RCC / Wall with the help of Anchor
C.1 fasteners ( Hilti or Equivalent) of stainless steel Grade 316. Rate shall include fixing of the main frames to RCC/ Sq.mtr. 900.00
Structure with necessary clamps / brackets, fastening straps, nuts, bolts, rivets, washers and other fastening
materials shall be in stainless steel grade 316. Rate shall include approved silicon sealant of recommended
grade from Dow Sill (DC 991) to fill gap between Louver & other cladding material all in line with the Tender
Drawing. Rate shall include aluminium bird mesh behind the louvers with neccessary aluminium cleat / framing
fixed by SS 316 screw all in line with the Tender Drawing.
BANER LIFESPACES LLP BILL OF QUANTITY WEST PORT

BOQ OF PROJECT : WEST PORT AT BANER, PUNE


RATE AMOUNT REMARKS
Sr.NO. ITEM DESCRIPTION UNITS QUANTITY
(Rs.) (Rs.)

The extruded Aluminum Sections of Alloy 6063 T6 and tolerances , flatness, twist , bend and angularity
confirming to DIN standard from approved extruder. All the visible surfaces of Louvers with system & Aluminium
Mesh shall have Powder Coating with a minimum thickness of 50 to 60 microns, shade shall be as per Clients
and Architect requirement. The non visible aluminium surfaces shall have minimum chromatizing treatment.

The quote rate shall include all design, engineering, shop drawing approval from Architect & consultant,
Scaffolding and statutory obligations and safety code compliance as per client.

Total Façade Area Sq.mtr. 2534.00

Total Amount (Without Tax)


Add GST
Extra if any
Total Amount (With Tax)
General Notes :
1 The System should be designed to resist wind pressure 1.3 KPA as per IS codes and also to accommodate the building movements.
2 All Structural Member Aluminum extrusions thickness shall not less than 2 mm & Shall be confirming to Alloy 6063-T6.
3 All the exposed aluminum section, Out side Flashings, Fins, Louvers shall be Powder Coating.
4 Non-exposed aluminum shall be chromotized.
5 All bolts, nuts and washers, screws used shall be only stainless steel of 304 grade & All Anchor used shall be only stainless steel of 316 grade Hilti
6 The quote Includes interface details such as flashing, sealants, extruded capping(if required), insulations (if required), brackets and anchors fasteners as required.

7 Quantity mentioned in this B.O.Q are Approximate quantities where we suggest Façade contractor/Fabricator/Sub - Contractor to Verify all the quantities as per site conditions, Drawings and Schedule of work.

Bill of Quantity description is indicative the Façade Contractor/Fabricator/Sub-Contractor shall be responsible to read the bill of quantity in conjecture with the Technical Specification, Tender drawings, Architectural
8
drawings or other related contract.
9 Any Addition / Modification / Revision in Cladding areas decided on site / as per site condition shall have Cost impact and same to be approve / Intimate to Façade Consultant.
10 Test Certificates and Quality Certificate for all Façade Item (Alum. Section, Glass, Silicone, Hardware, ACP Etc.) must be Provided by Fabricators before start the installation or fabrication.
11 System Dwgs, Shop Dwgs and Structural Calculations shall be approved by Architect and Façade Consultant (RSM DESIGN Solutions).
12 Anchor bolt pull out test has to be carried out on site before starting the installation.
13 The processing unit of the glass processor will be inspected by the client/ façade consultant before starting the work.
14 Contractor shall provide back to back guarantee on all the accessories used in the system.
15 Basic Rates of materials to be shown in covering letter while submitting Tender.
16 All the Glasses and alum. Section Shall be brought on the site with Proper covering, outer face with Protective film and same to be removed after the completion of work with proper clearing.
17 Certification will be based on actual measurement at site. Any variation has to be approved by the façade consultant.
18 Contractors has to carry on site water test as per IS code.