1 Function Description 1

1.1 Application 1

1.2 Working Principle 1

2 Fault Finding 3

3 Maintenance 5

3.1 Replacement of Solenoid


Valve 5

4 Technical Data 7

4.1 Specification 7

4.2 Dimensions 8

5 Spare Parts 9

1818009-02 V2
1818009-02 V2
1 Function Description

1.1 Application
The solenoid valve block supplies compressed
air to the pneumatically operated valve(s) in a
separation system.

1.2 Working Principle


Compressed air comes in to the valve block at
the shut-off valve (2). The air pressure is
indicated on the pressure gauge (1).

The valve block comprises one or two

G044291A
solenoid valves (4), depending on the
application. When voltage is supplied to a
Valve block with two solenoid valves
solenoid valve, it opens, and air is supplied
1. Pressure gauge
through its outlet. When the voltage goes off, 2. Shut-off valve
the valve closes. The quick de-aerator (6) 3. Drain port
ensures a fast evacuation of air from the 4. Solenoid valve
5. Override for manual valve operation
pneumatically operated valve, when the 6. Quick de-aerator
solenoid valve closes.

The valve has a lever for automatic or manual


operation. When the lever is turned to
horizontal position, the valve is operated
automatically, i.e, it is normally closed and
opens when the solenoid is energized. When
the solenoid is non energized, the valve can be
opened manually by turning the lever to the
vertical position.
G047871A

Valve block with one solenoid valve


Automatic operation; lever in horizontal position.

1818009-02 V2 1
1 Function Description Solenoid Valve Block, Air

2 1818009-02 V2
2 Fault Finding

Fault Probable cause Remedy


No metallic click Open circuit due to loose connection or Examine the electrical system and correct the
when energized. blown fuses. fault.

Low voltage (less than 85% of name plate Examine the power supply to the solenoid
rating). valve and correct the fault.

Too high voltage, coil burned-out. Replace the solenoid valve. Examine the pow-
er supply and correct the fault.

Leakage Faulty solenoid valve. Replace the solenoid valve.

1818009-02 V2 3
2 Fault Finding Solenoid Valve Block, Air

4 1818009-02 V2
3 Maintenance

3.1 Replacement of
Solenoid Valve

NOTE

Switch off electrical power and close


the shut-off valve to depressurize the
valve block before disassembly.

• Mark each pipe before dismantling to


make sure the inlets and outlets are
connected correctly when the valve is
remounted.

1818009-02 V2 5
3 Maintenance Solenoid Valve Block, Air

6 1818009-02 V2
4 Technical Data

4.1 Specification
Valve housing material Brass
Seals Viton
Air/gas pressure 0 – 10 bar
Ambient temperature 50°C
Cable gland PG11 for cable Ø 9 – Ø 11
Protection class IP 65
Voltage 48 V 50/60 Hz
Power consumption, holding 2.5 W
Power consumption, inrush 10.4 VA
Mounting Valve may be mounted in any position
Continuous duty moulded coil class F
Ref. 1763253 Rev. 3

1818009-02 V2 7
4 Technical Data Solenoid Valve Block, Air

4.2 Dimensions

X001862A

Ref. 1763253 Rev. 3

8 1818009-02 V2
5 Spare Parts

4 8
0,6
0,4 MPa 0,8

2 0,2 1 10

bar
0 1,2

0 12

G051771A

Item Qty Article No. Description Remarks


1 1 1763889-01 Solenoid valve

1818009-02 V2 9