Professional Documents
Culture Documents
Motor Calculation of Crane
Motor Calculation of Crane
2 Lift
DG EOT Crane
Camb = Derating Factor for the required ambient Temperature (50°C): 0.88
= Mechanical rating
Camb
= 28.56 = 32.46 kW
0.88
TEFC, 60% CDF, S4 Duty, IP55, 6 Pole, 1000rpm (SYN), CL-F, B3, Single Shaft Extension.
15T x 20m Span x 10.2 Lift
DG EOT Crane
Brake
Min. Braking Torque Required As Per IS
= 150 % of the Rated Torque Transmitted to the Brake Drum from the suspended
Maximum Safe Load and the Brake not being taken into consideration
S = Service Factor For Providing Adequate Motor Heat Dissaption Capacity: 1.06
Camb = Derating Factor for the required ambient Temperature (50°C): 0.88
= 1.16 KW
= Mechanical rating
Camb
= 1.16 = 1.32 kW
0.88
TEFC, 60% CDF, S4 Duty, IP55, 6 Pole, 1000rpm (SYN), CL-F, B-3, Single Shaft Extension.
15T x 20m Span x 10.2M Lift
DG EOT Crane
Brake
Min. Braking Torque Required As Per IS
= 100 % of Motor Torque
Maximum Safe Load and the Brake not being taken into consideration
Camb = Derating Factor for the required ambient Temperature (50°C): 0.88
= 4.25 KW
= Mechanical rating
Camb
= 4.25 = 4.83 kW
0.88
TEFC, 60% CDF, S4 Duty, IP55, 6 Pole, 1000rpm (SYN), CL-F, B-3, Single Shaft Extension.
15T x 20m Span x 10.2M Lift
DG EOT Crane
Brakes
Min. Braking Torque Required As Per IS
= 100 % of Motor Torque
Maximum Safe Load and the Brake not being taken into consideration