Planning Document: EMT/EMT-F/GS-100T Four Leaf Double Leaf Left/right

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 12

Planning Document

EMT/EMT-F/GS-100T
Four leaf
Double leaf left/right
EMT/EMT-F/GS 100T

Sectional view EMT/EMT-F/GS-100T


Mounting height = DLH + 35

DLH = PH + 5
PH

2
Planning Document

4 leaf EMT/EMT-F/GS-100T

Length with end sheet = Basic slide rail + 12 mm

Length cover profile = Basic slide rail + 8 mm


Basic slide rail = OW x 1.5 + 100 mm

Length slide rail EM/EMT = Basic slide rail + 12 mm

4 leaf

Minimum dimension OW 1400 mm PH


Maximum dimension OW 3800 mm PH 3000
Maximum weight leaf 80 kg per leaf
Ratio width-height leaves width 1 : height 4

Culculation drive Draft number 046_050

Dimension basic slide rail Basic slide rail = OW x 1,5 + 100 mm


Dimension EM/EMT slide rail Basic slide rail - 4 mm
Dimension cover Basic slide rail + 8 mm
Dimension belt OW x 2 +1100 mm
Dimension OW sheet OW / 2 + 4 mm
Jamb width on both sides at opened leaf (Ü) Jamb width = 26

Calculation leaf Draft number 046_050

Telescopic side leaf Draft number 046_043


Draft material number A-9002400
Door leaf height DLH = PH + 5mm
Door leaf width DLW = OW / 2 +20mm
Telescopic leaf Draft number 046_044
Draft material number A-9002410
Door leaf height DLH = PH + 5mm
Door leaf width DLW = OW / 2 + 25mm

3
4
OW

DL intermediate size
EMT/EMT-F/GS 100T

DLW = OW/4 + 20 mm DLW = OW/4 + 25 mm


4 leaf EMT/EMT-F/GS-100T
Planning Document

4 leaf EMT/EMT-F/GS-100T left/right

Length with end sheet = Basic slide rail + 12 mm


Length cover profile = Basic slide rail + 8 mm
Length slide rail = Basic slide rail - 4 mm
Length basic slide rail

double leaf

Minimum dimension EMT / EMT-F OW 800 mm / 900 mm PH


Maximum dimension OW 2500 mm PH 3000 mm
Maximum weight door 80 kg per leaf
Ratio width-height leaves width 1 : height 4

Culculation drive Draft number 046_065

Dimension basic slide rail


EMT double leaf / right Basic slide rail = OW x 1,5 + 180 mm
EMT-F double leaf left / right Basic slide rail = OW x 1,5 + 180 mm
Dimension EM/EMT slide rail Basic slide rail - 4 mm
Dimension cover Basic slide rail + 8 mm
Dimension belt
EMT double leaf left OW x 2 + 520 mm
EMT double leaf right OW x 2 + 770 mm
EMT-F double leaf left OW x 2 + 660 mm
EMT-F double leaf right OW x 2 + 950 mm
Dimension OW sheet OW / 2
Jamb width at opened leaf (Ü)
EMT double leaf left / right Jamb width = 65 mm
EMT-F double leaf left / right Jamb width = 154 mm

Calculation leaf Draft number 046_065

Telescopic side leaf Draft number 046_043


Draft material number A-9002400
Door leaf height DLH = PH + 5mm
Door leaf width DLW = OW / 4 + 20mm
Telescopic leaf Draft number 046_044
Draft material number A-9002410
Door leaf height DLH = PH + 5mm
Door leaf width DLW = OW / + 15mm

5
EMT/EMT-F/GS 100T

4 leaf EMT/EMT-F/GS-100T left/right


DLW = OW/2 + 20 mm

DLW = OW/2 + 5 mm

6
Planning Document

Additional planning documents

Installation manuals For supplemental information we refer to the following documents:

zz Additional Installation Manual ID.-No.: A-7147500


econoMaster Telescopic sliding door
EMT/GS-100T

zz Installation Manual ID.-No.: A-7149960


G30 system of profiles

Drafts More drawings are available in appendix.

7
Your specialist dealer:

Gretsch-Unitas GmbH GU Automatic GmbH GU Service GmbH & Co. KG GU Baubeschläge Austria GmbH
Baubeschläge Stahlstraße 8 Stahlstraße 8 Mayrwiesstr. 8
Johann-Maus-Str. 3 D-33378 Rheda-Wiedenbrück D-33378 Rheda-Wiedenbrück A-5300 Hallwang bei Salzburg
D-71254 Ditzingen Tel.: +49 (0) 52 42 9 24-0 Tel.: +49 (0) 52 42 9 24-0 Tel. + 43 (0) 6 62 66 48 30-0
Tel. + 49 (0) 71 56 3 01-0 Fax: +49 (0) 52 42 9 24-100 Fax: +49 (0) 52 42 9 24-104 Fax + 43 (0) 662 664 830 401
Fax + 49 (0) 71 56 3 01-2 93 E-mail: info@gu-automatic.de E-mail: service@gu-service.de

www.g-u.com A-7150740 Index 01 07/2011 Subject to changes without announcement Printed in Germany
Automatic GmbH
Automatic GmbH
Automatic GmbH