Deep Freezer: Operation Instruction
Deep Freezer: Operation Instruction
Deep Freezer: Operation Instruction
Operation Instruction
·Please read the operation instruction before installing and
the directions.
by our company.
I Main performance and characteristics of the product
Thermal insulating door and secondary seal door are adopted for use
can be put in or taken out easily. The refrigeration effect is good and the
Users can regulate and check the inside temperature and the working
The system is equipped with a safety protection device for ensuring the
The refrigerating system all adopts imported parts which provide good
1
II Precautions
The sign of “ ” means the place is dangerous to human bodies, or
the use pattern is harmful to products, or alarm users should pay special
attention to this.
transportation.
conditioning.
:The slant angle of the body of the deep freezer should not be larger
:Do not put it near the heat source and avoid the sunshine
:If the deep freezer has to be stopped for a long period, it should be
cleaned inside and outside and then covered properly with a plastic
housing.
please equip a power regulator which is above 1000VA and please use it
alone.
ground wire. The ground wire cannot be connected with gas pipe, stem
heating pipe and water pipe and the zero line of single-phase source should
:If the power connect wire has to be lengthened, the sectional area
:The deep freezer cannot lean against the wall. The space of at least
30cm should be left at the machine room for normal running of the system.
into the control panel and the compressor room. It is also prohibited to use
the product in the rain or under the environment with the relative humidity
of larger than 85%. Otherwise, faults such as electric leakage etc. may be
caused.
: The key of the deep freezer should be kept out of the reach of
deep freezer.
grade 2.
4
V Start and test machine
·Plug in the socket and switch on the power switch (located at the right
side of the temperature controller on the front part of the body). Then the
power supply indicator light is on. In order to ensure the normal running of
the cryogenic freezer, be sure to use the socket which is above 16A.
refrigeration indicator light is on. The system goes into refrigerating cycle
state.
·After the power has been supplied for a period of time, the
·Before storing articles, please keep the freezer running in empty state.
When the freezer is running stably (it is best to keep it running in empty
state for 5 hours above) and the inside is cooled completely, the cold store
Model BDF-86H300
Type Horizontal
Total effective volume (L) 258
Storage temperature -40℃~-86℃
Rated voltage (v) 220V
Frequency (Hz) 60
Rated power(W) 780
Electric-shock protection class Class I Type B
Type of alarm Sound-light alarm
5
Climate type N
Refrigerating fluid Fluoride-free mix
Net weight of machine (Kg) 240
Machine dimensions width×depth×height (mm) 1510* 885* 1095
Notes: technical parameters in this table are measured at the standard state.
Please be subject to the nameplate of the goods freezer without prior notice in case
of variation.
2. Description
The KLT11IB is designed for heating and cooling applications. The probe
temperature is displayed on the bright 3-digit display . The user is able to program
different parameters including set point, hysteresis, alarms and probe adjustment using
the silicone front keypad. The unit features error or alarm warning, internal buzzer
(optional), configurable digital input and password protection. The KLKey input
allows an easy programming of the parameters. Select between temperature display in º
C or ºF , display color and 230V ac, 115V ac, 24V ac/dc or 12V ac/dc power supplies.
3. Mai nt en a nc e, cl e a ni n g an d rep a i r
Aft er fi nal in s t al l at i on of the uni t , no rout i ne ma in ma int e n ance is
requ i re d.
Cl ea n th e su rf ace of the di s pl ay con t rol l er wit h a sof t and da m p
cl o th . Ne ver us e ab ras i ve det e rgent s , pe t rol , alc oh ol or sol vent s .
All re pai rs mu s t be ma d e by aut hori ze d pe rs on nel .
6
4. List of parameters
7
5. Parameter descriptions
SP = Set poi n t . Tem p era t u re we wis h to re g ul at e the mac hi ne
(v ari a b le from r1 to r2 )
r0 = Di ff ere nt ia l or hys t ere s i s
R1 = Lower va lue for SP
r2 = Hi g her va l u e for SP
r4 = Set po i nt va ri at i on fo r ener gy sa vi ng. If di gi t al inp ut
co n fi gura ti o n E0 ES th i s va l ue mod i fy the se t poi nt as fol low s:
If d0= Ht ne w SP= SP - r4
If d0= Co ne w SP = SP + r4
do = Cool i ng or he at i ng co nt rol
If d0 = Ht an d TS is th e te mpe ra tur e of am b ie nt pr obe:
If TS >= SP th e loa d is di s c onnect e d
If TS <= SP - r0 the loa d is con nect e d
If d0 = Co th en :
If TS <= SP the loa d is di s c o nnect e d
If TS >= SP + r0 the loa d is con nec te d
c0 = Mi ni mum st op pi ng ti m e of the loa d
c2 = Ou t p ut st a tus wit h pr obe error
P1 = Ambi e n t pr ob e ad j u s tm e n t
P4 = Deci m al poi n t
P5 = 3 wir es Pt 10 0. no = 2 wir es , yes = 3 wir es
E0 = Dig i t al in pu t co nfi gura ti on
OFF = Digi t al in pu t di s ab l e d
Al = Exte rn al al arm (i f in put is shor t- ci rc uit e d)
ES = Energy Savi ng . Set Poi nt va l ue is mod i fi e d in r4.
HC = if in pu t is sh ort - ci rcui t ed , it change s to Heat or Col d
de p end i n g of d0 va lu e .
if d0 = Heat it chang es to Col d mod e .
if d0 = Co l d it chang es to Heat mod e .
6. Parameter programming
Set Poi nt (SP ) is th e onl y pa ra me t er the us e r can
acc es s wit hou t co de pr ote ct i on.
• Pre s s SET . SP te xt wil l app e ar on the di s pl ay .
• Pre s s SET ag ai n . Th e rea l val u e is show n on the di s pl ay.
• Th e val ue can be mo di fi e d wit h the UP and DOWN arrow s .
• Pre s s SET to en t er an y ne w va lue s .
• Pre s s SET an d DOWN at the sa m e ti m e to qui t
pr o g ram m i ng or wa i t on e mi n ut e and the di s pl ay wil l
au t o ma t ic al l y ex i t pr og ram m i ng mod e .
9. Alarm validation
In cas e of al arm th e in t er nal buz zer and ala rm le d is act i vat ed . Th e
di s pl ay sh own th e co rre s po ndi ng me s sa ge. Th e buz ze r and di s pl ay
me s sa ge can be si l en c ed pr es s i ng the SET and DO WN arrow s at th e
sa m e ti me . If ala rm co nt in ue s af t er A8 it is si gna ll i ng agai n.
IX Storage essentials
·Before storing articles, please keep the freezer running in empty state.
When the freezer is running stably (it is best to keep it running in empty
state for 5 hours above) and the inside is cooled completely, the cold store
too much. Proper clearance should be left to help the circulation of the
2
The refrigerating system of the deep freezer is a device used for
other quick-freezing plant and then store them in the freezer to avoid
by 10℃ in every step and then maintained for 1-2 hours until the storage
temperature is reached.
·When storing plastic bag products, please note that do not get them
X Maintenance
·Body cleaning: please use non-corrosive neutral cleaning agent to clean
the inside and outside surfaces of the deep freezer and then use dry cloth to
wipe it up.
and outside surfaces of the freezer so as not to affect the insulating property
cleaning.
3
·Regularly wipe a little talcum powder on the door seal to extend the
·If the deep freezer has been running for a long time, frost may be
easily accumulated on the door seal, the opening part of the freezer and the
side wall inside the freezer. If the frost layer is too thick, the sealing
and outside surfaces of the freezer and then use dry cloth to wipe it up.
·Machine halt: when stop using the freezer, unplug the power plug, clean
it according to the above method, cover it with a plastic bag after natural
XI Non-fault phenomenon
·Sound of running water can be heard in the deep freezer: this is the
·You may feel a little hot on the two sides of the body (close to the
door body) when the freezer is running. That is because the leak proof tube
dry.
controller
·If the power plug wire is properly connected and the main power
supply is plugged in
·The door is opened too often for too long: try to reduce the
door-opening time
·The storage capacity is too much: take some out or distribute evenly to
·The condenser is dirty and the heat dissipation is not good: clean the
5
·The condensate fan in the machine room is broken: it is necessary to
3.Large noise
·If the back part of the freezer body contacts with the wall: please
·The fan in the machine room makes a lot of noise: the fan is broken
Notes: if the deep freezer still cannot work normally after being
inspected and handled according to the above methods, please contact the
company’s products and maintain the legal rights of the consumers, our
Bureau of Finance and provide you with following services basing on the
The whole machine can enjoy life service. And we will charge for
caused by the fact that the user does not operate according to the
invoice
7
Packing Accessories
1 1 2
To distributor:
The warranty card should be full filled by distributor, only effective with seal and filed by
sales department.
Product name:
Product model:
Final user (or unit) name: Guarantee period:
Final user (or unit) address: Phone No.:
Purchase date:
Distributing unit name: (effective with seal)
Phone No.: Address:
After filling it, please cut it off along the dash line.
Product name:
Product model:
Final user (or unit) name: Guarantee period:
Final user (or unit) address: Phone No.:
Purchase date:
Distributing unit name: (effective with seal)
Phone No.: Address: