500 500

SHYNESS SHYNESS 1500 SHYNESS SHYNESS


16110 1750 1750 7000
7000 1750 1750
PS F.P/
MEDIAN 16158
GL.363.253
TO MUDKHED TO BELLUR
F.P/ PS LEFT MAIN
RIGHT MAIN GL.363.749
DRAIN CARRIAGEWAY
CARRIAGEWAY DRAIN
PCL 65mm THK.WEARING COAT 0.00 0.00 2/1
CRASH BARRIER A FRL:367.292 FRL:367.482 CD.NO.:
FRL:367.482 FRL:367.292 CRASH BARRIER 2
-2.0% 2.0%
CL SM Design Chainage 1+18
LHS EDGE FRL:367.257 RHS EDGE FRL:367.257 6
N=33 1.50 Existing Chainage 1+18
650 TOP SLAB Span (m) 4x8.5 m
Proposed
m
DRAINAGE SPOUT N=36 C1(25%/0%) Existing Span (m) 3x8.0
r Bridge

1000
WEEP HOLES (TYP) Type of Structure Mino
2 2 Reco nstru ction
1 Proposal

NALA
1 367.482
U/S 7340 1000
7364 D/S 4.50 C2(32%11%) Achieved FRL
AS6

N=42
SLOPE 1:1000 SDR C3(43%41%)
IL:359.201 IL:359.177
C1(8%/7%) ROCK
700 BOTTOM SLAB
900MM FILLED BY 7.00
CURTAIN WALL METAL/BOULDERS WITH SAND C4(65%/65%)
COMPACTED GRANULAR CURTAIN WALL
(REFER NOTE NO.24) C2(9%0%)

1+300
B

1+200
3000 16110 LHS 24000 MATERIAL RHS 16158 6000 BMP6

1+100

NALA
PROPOSE LENGTH NEWBMP5
LONGITUDINAL SECTION A-A SCALE (1:250) ROCK C5(65%/65%)
C3(11%9%)

359.477 367.257
359.501 367.257

367.292

367.482

367.482

367.292
FRL C6(70%/68%)
KEY PLAN
C4(20%/13%)

359.489
OGL 12.00 12.00 NOTES :-
16110 1750 1750 7000 1500 7000 1750 1780 16158 BH-01 BH-02 1. ALL DIMENSIONS ARE IN MILLIMETRES AND LEVELS ARE IN METERS,
250 500 PCL 500 250 B UNLESS OTHERWISE SPECIFIED.
SLOPE 1V : 2H SLOPE 1V : 2H 2. DIMENSIONS OF THE DRAWING SHALL NOT BE MEASURED
FROM THE DRAWING. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED.
GL.359.379 GL.362.841 GL.363.668 GL.362.803 3. CODES FOLLOWED FOR THE DESIGNS OF STRUCTURES:
TO BELLUR 0.00 0.00 0.00 0.00 a) IRC: 5-2015 c) IRC: 112-2011

RETAINING WALL
RETAINING WALL

1V : 1.5H
1V : 1.5H

BOULDER BOULDER BOULDER b) IRC: 6-2017 d) IRC: 78-2014 e) IRC SP: 13-2004

N=39 4. GRADE OF CONCRETE SHALL BE AS FOLLOWS :-


1.50 1.50 1.50

11400
11363

LEVELLING COURSE
----------------- M15
C1(16%/0%) SDR BOX CELL ----------------- M30
N=50 CRASH BARRIER ----------------- M40

APPROACH
SLAB
C2(24%0%) 5. MINIMUM CLEAR COVER TO ANY REINFORCEMENT SHALL BE AS FOLLOWS :-

3500
C1(15%/08%) C1(36%/24%) 1.50
20 STR. GAP EARTH FACE ----------------- 75
C1(21%/0%) NON EARTH FACE
----------------- 40
700 C3(37%0%)
C2(15%0%) C2(43%43%)
ROCK ROCK ROCK ROCK 6. BACK FILLING FOR SIDE WALL AND RETAINING WALLS SHALL CONFORM
C2(31%17%) TO SPECIFICATION APPENDIX-6 OF IRC : 78-2014.
C4(45%/8%)
C3(51%46%) C3(39%35%) 7. THE PROPERTIES OF THE MATERIALS USED FOR BACK FILLING BEHIND
A A C3(19%0%)
8500

C5(51%/51%) SIDE WALL AND RETAINING WALLS SHALL CONFORM TO THE FOLLOWING
C4(57%/55%) C4(53%/53%) Ø < 30° & rd = 20 kN/m³
C4(20%/0%)
C6(57%/55%) 8. SOFT AND LOOSE PATCHES IN THE BEARING AREA ARE TO BE REPLACED
DRAINAGE C5(62%/58%)
5000(TYP.)

C5(58%/53%) BY COMPACTED GRANULAR FILLS WITH LAYERS NOT EXCEEDING 300 .


SPOUT
450 C6(65%/61%) 9. COMPRESSIBLE FILLER BOARD SHALL BE PROVIDED IN ALL STRUCTURE GAPS
C6(61%/57%) C7(59%/57%) PROVIDED BETWEEN STRUCTURES .
C7(73%/65%)
FOOTPATH/ DRAIN

12.00 12.00 12.00 12.00


FOOTPATH/ DRAIN

CRASH BARRIER

10. PROTECTION WORKS SHOULD BE DONE AS PER SITE


CRASH BARRIER

BH-03 BH-04 BH-05 BH-06 CONDITION AND AS PER INSTRUCTIONS OF ENGINEER IN CHARGE.
11. ANY DISCREPANCY NOTED SHOULD BE REPORTED TO THE DESIGN
8500

CONCRETE (TYP.)
ENGINEER IMMEDIATELY.

STONE APRON
300 THICK M15

1000 THICK

(FLEXIBLE)
12. THE SAFE BEARING CAPACITY CONSIDERED FOR THIS BOX STRUCTURE
CONCRETE (TYP.)

U/S
STONE APRON

300 THICK M15

IS 15.00 t/m². THE SAME SHALL BE CONFIRMED AT SITE BEFORE EXECUTION.


1000 THICK

(FLEXIBLE)

CLAY WITH LOW COMPRESSIBILITY(CL) 13. ALL THE LEVELS AND CAMBERS TO BE VERIFIED WITH RESPECT TO
450 D/S PLAN AND PROFILE DRAWINGS BEFORE STARTING UP OF EXECUTION.
14. BACK FILLING BEHIND WALLS SHALL BE DONE SIMULTANEOUSLY
SOFT DISINTEGRATED ROAK (SDR)
AFTER CASTING OF TOP SLAB.
15. WEEP HOLES OF 100 DIA SHALL BE PROVIDED AT 1000 C/C
8500

BOTH HORIZONTALLY AND VERTICALLY IN A STAGGERED MANNER


SILTY SAND(SM)
IN SIDE WALLS OF BOX CELL AND RETAINING WALLS ABOVE 150
LEGEND :-
FROM GL OR LWL WHICHEVER IS HIGHER.
FRL = FINISHED ROAD LEVEL
IL = INVERT LEVEL 16. 600 THICK FILTER MEDIA SHALL BE PROVIDED BEHIND SIDE WALLS
BOULDER U/S = UP STREAM
450 GL = GROUND LEVEL AND RETAINING WALLS AS PER IRC : 78 - 2014.
LHS = LEFT HAND SIDE 17. DRAINAGE SPOUT, COLLECTION PIT ASSEMBLY AND DRAINAGE PIPE SHALL
ROCK = DOWN STREAM RHS = RIGHT HAND SIDE BE FABRICATED FROM MILD STEEL AND AFTER THE COMPLETE ASSEMBLY,
D/S EXCEPT GRATING, SHALL BE GIVEN A HOT DIPPED GALVANISED COATING.
P.S = PAVED SHOULDER
8500

EXP. = EXPANSION 18. FOR DETAILS OF RETAINING WALL REFER SEPARATE DRAWING.
BORE HOLE DETAIL = LEVEL TYP. = TYPICAL 19. RETAINING WALL LENGTH AND HEIGHT VARIES AS PER SITE CONDITION.
PCL = PROPOSED CENTRE LINE 20. ALL DIMENSIONS AND LEVELS SHOULD BE VERIFIED BEFORE EXECUTION
THK = THICK
OF WORK.
F.P = FOOTPATH
21. FOR DETAILS OF APPROACH SLAB, CRASH BARRIER RCC POST AND DRAINAGE
STR. = STRUCTURE GAPS
700 SPOUT REFER MISCELLANEOUS DRAWING.
APPROACH

22. FLOOR PROTECTION WILL BE PROVIDED AT U/S AND


SLAB

20 STR. GAP
3500

D/S, AS PER IRC SP: 13-2004.


REFERENCE DRAWINGS:
23. SEISMIC ZONE-II
RETAINING WALL

RETAINING WALL

1. GENERAL ARRANGEMENT DRAWING : VC/459/AU-106/STR/MNB/1+182/101(SHEET 2 OF 2)


2. REINFORCEMENT DETAILS : VC/459/AU-106/STR/MNB/1+182/201(SHEET 1 OF 2) 24. BEFORE CONSTRUCTING PROTECTION WORKS IN U/S & D/S, FLOW DIRECTION
SHOULD BE VERIFIED AT SITE.
11363

11400

3. MISCELLANEOUS DETAILS: VC/459/AU-106/STR/MIS/001


1V : 1.5H

1V : 1.5H
TO MUDKHED

4. RETAINING WALL DETAILS: VC/459/AU-106/STR/RE/001 25. PITCHING / REVETMENT ON SLOPES TO BE PROVIDED AS PER MORTH SPECIFICATION.
26. IF BC/ CLAYEY SOIL ENCOUNTERED AS FOUNDING SOIL. THEN 900mm. DEPTH OF SOIL
BELOW FOUNDATION TO BE REMOVED OF FILLED BY METAL / BOULDER WITH SAND
HYDROLOGY DETAILS AS PER SP-13.

HFL (AFFLUXED) 365.276


DISCHARGE (Q) 737.550 M³/sec
SLOPE 1V : 2H 300 THICK DRY STONE VELOCITY (V) 4.339 M/sec
SLOPE 1V : 2H PITCHING OVER 150 THICK

PLAN (SCALE 1: 250) B GRAVEL BACKING(TYP.) SCOUR LEVEL 357.099


GOOD FOR CONSTRUCTION
AUTHORITY: INDEPENDENT ENGINEER: SAFETY CONSULTANT: CONCESSIONAIRE: CONTRACTOR: DESIGN CONSULTANT: PROJECT: DRAWING TITLE: (SHEET NO.1 OF 2) SCALE

GENERAL ARRANGEMENT DRAWING OF MINOR BRIDGE AS SHOWN


CONSTRUCTION OF TWO LANING ROAD WITH
PAVED SHOULDERS UNDER HYBRID ANNUITY AT CH: 1+182 (RECONSTRUCTION)
ISSUED AS GFC WIDE
C0 11-03-2020 LETTER NO:19001/IE 106/1152. Dt:06-02-2020 NG DATE
PACKAGE AU-106 MUDKHED-UMARI-RAMKHADAK
MAR - 2020
R2 03-02-2020 REVISED AS PER P & P AND IE COMMENTS NG INFRASTRUCTURE DESIGN CONSULTANTS Shardamudkhed Chincholi Vasuprada Consultants LLP -BABHULGAON-DHARMABAD-CHINCHOLI DRAWING NUMBER: VC/459/AU106/STR/ MNB/1+182/101
Padmapriya Consulting LLP
PUBLIC WORKS DEPARTMENT PVT LTD (IDCPL) Highway Pvt.Ltd. Sharda Construction & Corporation Pvt.Ltd. Flat C-11, CEL Apartments KM. 0/00 TO 67/559 IN NANDED DIST.
R1 25-08-2019 AS PER IE COMMENTS GAR Hariviluu, House No. 24 155/15/1, Shipyard DRAWN DESIGNED CHECKED APPROVED REV
GOVERNMENT OF MAHARSHTRA F 1/D 6, Shanti Apartments Owners Association, Plot Layout, Vepagunta, Visakhapatnam, P.No.72, Sharda Towers, P.No.72, Sharda Towers, Vasundhara Enclave,
R0 16-05-2019 INITIAL SUBMISSION GAR No. 3, Beside Bus Depot, Sector - 11, Nerul - East,
NANDED DIVISION Andhra Pradesh, Pin Code 530 047 Ashok Nagar, Nanded-5, Ashok Nagar, Nanded-5, Maharashtra. C0
NO DATE REMARKS BY Navi Mumbai - 400706 Maharashtra. New Delhi -110 096 MF NG YPK TRB