Concrete thickness ha 700 mm

The load bearing length le 128 mm


ca1 150 mm
Basic concrete breakout strength in shear of a single anchor Vb 33 kN
Projected area for a single anchor Avc0 101250 mm2
Avc 118125 mm2
Eccentricity of centroid of group for shear ev 0 mm
Modification factor for eccentricity in shear Ψec,V 1
Modification factor for edge effect Ψed,V 1

For anchors in cracked concrete with no supplementary Ψc,V 1


reinforcement or edge reinforcement smaller than a No. 4 bar
Design concrete breakout strength for group of anchors ΦvVcbg 27 kN
Check ratio (Vzmax/Φ*Vcbg) 0.40 < 1 OK
Design concrete breakout strength for a single anchor ΦvVcb 27 kN
Check ratio (Vzmax/Φ*Vcbg) 0.40 < 1 OK
2) Concrete Pryout Strength of Anchor In Shear
kcp 2
Nominal concrete pryout strength for group of anchors Vcpg 180 kN
Design pryout strength for group of anchors ΦvVcpg 126 kN
Check ratio (Vzmax/Φ*Vcpg) 0.09 < 1 OK
Nominal concrete pryout strength for a single anchor Vcp 90 kN
Design pryout strength for a single anchor ΦvVcp 126 kN
Check ratio (Vzmax/Φ*Vcp) 0.087 < 1

D) INTERACTION OF TENSILE AND SHEAR FORCES


The lowest design strength due to tension ΦNng 63 kN
The lowest design strength due to shear ΦVng 27 kN
Check interaction 1.12 > 1.2 NOT OK
The lowest design strength due to tension ΦNns 41
The lowest design strength due to shear ΦVns 27
Check interaction 1.50 > 1.2 NOT OK