PREDIMENSIONAMIENTO DE ZAPATAS

EJE A-1 COLUMNA C6 (PUNTO 06 - SAFE)

DATOS GENERALES
Cargas de Servicio P [kg] 0
f'c = 210 [kg/cm2] Dead (D) Live (L)
f'y = 4200 [kg/cm2] 19,191 4,210
s adm = 1.10 [kg/cm ]2

hf = 1.7 [m]
gm = 1670 [kg/m3]
SC = 200 [kg/m2]

Caso 1: D 19,191 [kg]


Caso 2: D + L 23,401 [kg]

Dimensiones Columna

a = 0.40 [m] Lado Mayor


b = 0.30 [m] Lado Menor
f = 15.88 [mm] Armadura Columna
PREDIMENSIONAMIENTO

Tensión Neta s neta = 0.7961 [kg/cm2]


Factor peso propio f= 4%
Area Necesaria
Caso 1: Anec = 2.51 [m2]
Caso 2: Anec = 3.06 [m2]
3.057
Dimensiones A= 1.80 [m]
B= 1.70 [m] A-a = 1.40
Adoptado A= 1.80 [m] B-b = 1.40
B= 1.70 [m]
v= 0.70 [m]
h= 0.35 [m]
hadop = 0.40 [m] f = 5/8 '' Cover 15.88 [mm]
recub. = 0.075 [m] d= 0.31 [m] 0.0909 m

VERIFICACION DE TENSIONES

Caso 1: σ1 = 0.63 [kg/cm2] < 0.80 [kg/cm2] CUMPLE


Caso 2: σ2 = 0.76 [kg/cm2] < 0.80 [kg/cm2] CUMPLE

DISEÑO DE ARMADURA

Caso 1: 1.4*D 26868 [kg]


Caso 2: 1.4*D+1.7*L 34025 [kg] Pu = 34025 [kg]

Reacción del terreno Wnu = 11.12 [t/m2]

Cálculo de bc bc = 1.3

Perímetro crítico Bo = 263.65 [cm]


VERIFICACIÓN AL PUNZONAMIENTO
Corte absorbido por
el Hormigón Vc = 125,192 [kg] D/C
f *Vc = 106,413 [kg] ø = 0.85 0.275

Corte de diseño Vu = 29,222 [kg] Vu < fVc CUMPLE

VERIFICACIÓN AL CORTE

q = Wnu*B = 18.90 [t/m]

v-d= 0.39 [m]

Vd = q*(v-d) = 7388.599 [kg]

Cálculo de Vc
Vc = 40362 [kg]
f*Vc = 30271 [kg]

Vd < fVc CUMPLE

DISEÑO POR FLEXIÓN

Mu = 4631 [kg-m] a = d/5 = 0.06 [m]

As = 4.40 [cm2] a= 0.58 [cm]


As = 4.00 2
[cm ] a= 0.52 [cm]
As = 4.00 [cm2] a= 0.52 [cm] 3 f 5/8 5/8

Armadura Minima As min = 0.0018*B*d


Dispuesto
As min = 9.46 [cm2] Þ 5 f 5/8 5/8 As real = 9.90 [cm2]

Ast = 10.02 [cm2] Þ 6 f 5/8 5/8

TRANSFERENCIA DE FUERZAS A LA COLUMNA Y CIMENTACIÓN

Resistencia a aplastamiento sobre la columna

Pu = 34025 [kg] f = 0.65

Pn = 52346 [kg]

Resistencia de la columna a aplastamiento

Pnb = 214200 [kg] Pn < Pnb CUMPLE

Resistencia a aplastamiento en la superficie de contacto

ÖA2/A1 = 5.0 Þ Ao = 2400 [cm2]

Pnb = 428400 [kg] Pn < Pnb CUMPLE

Armadura de Transferencia As min = 0.005*Ag = 6.0 [cm2] 4 f 5/8 5/8


PREDIMENSIONAMIENTO DE ZAPATAS
EJE A-1 COLUMNA C6 (PUNTO 06 - SAFE)

DATOS GENERALES
Cargas de Servicio P [kg] 0
f'c = 210 [kg/cm2] Dead (D) Live (L)
f'y = 4200 [kg/cm2] 33,832 8,238
s adm = 1.32 [kg/cm ]2

hf = 2.0 [m]
gm = 1670 [kg/m3]
SC = 200 [kg/m2]

Caso 1: D 33,832 [kg]


Caso 2: D + L 42,070 [kg]

Dimensiones Columna

a = 0.40 [m] Lado Mayor


b = 0.25 [m] Lado Menor
f = 15.88 [mm] Armadura Columna
PREDIMENSIONAMIENTO

Tensión Neta s neta = 0.9660 [kg/cm2]


Factor peso propio f= 2%
Area Necesaria
Caso 1: Anec = 3.57 [m2]
Caso 2: Anec = 4.44 [m2]
4.442
Dimensiones A= 2.18 [m]
B= 2.03 [m] A-a = 1.80
Adoptado A= 2.20 [m] B-b = 1.75
B= 2.00 [m]
v= 0.90 [m]
h= 0.45 [m]
hadop = 0.60 [m] f = 5/8 '' Cover 15.88 [mm]
recub. = 0.075 [m] d= 0.51 [m] 0.0909 m

VERIFICACION DE TENSIONES

Caso 1: σ1 = 0.77 [kg/cm2] < 0.97 [kg/cm2] CUMPLE


Caso 2: σ2 = 0.96 [kg/cm2] < 0.97 [kg/cm2] CUMPLE

DISEÑO DE ARMADURA

Caso 1: 1.4*D 47365 [kg]


Caso 2: 1.4*D+1.7*L 61370 [kg] Pu = 61370 [kg]

Reacción del terreno Wnu = 13.95 [t/m2]

Cálculo de bc bc = 1.6

Perímetro crítico Bo = 333.65 [cm]


VERIFICACIÓN AL PUNZONAMIENTO
Corte absorbido por
el Hormigón Vc = 260,934 [kg] D/C
f*Vc = 221,794 [kg] ø = 0.85 0.233

Corte de diseño Vu = 51,744 [kg] Vu < fVc CUMPLE

VERIFICACIÓN AL CORTE

q = Wnu*B = 27.90 [t/m]

v-d= 0.39 [m]

Vd = q*(v-d) = 10903.63 [kg]

Cálculo de Vc
Vc = 78206 [kg]
f*Vc = 58654 [kg]

Vd < fVc CUMPLE

DISEÑO POR FLEXIÓN

Mu = 11298 [kg-m] a = d/5 = 0.10 [m]

As = 6.52 [cm2] a= 0.70 [cm]


As = 5.91 2
[cm ] a= 0.63 [cm]
As = 5.91 [cm2] a= 0.63 [cm] 3 f 5/8 5/8

Armadura Minima As min = 0.0018*B*d


Dispuesto
As min = 18.33 [cm2] Þ 10 f 5/8 5/8 As real = 19.79 [cm2]

Ast = 20.16 [cm2] Þ 11 f 5/8 5/8

TRANSFERENCIA DE FUERZAS A LA COLUMNA Y CIMENTACIÓN

Resistencia a aplastamiento sobre la columna

Pu = 61370 [kg] f = 0.65

Pn = 94415 [kg]

Resistencia de la columna a aplastamiento

Pnb = 178500 [kg] Pn < Pnb CUMPLE

Resistencia a aplastamiento en la superficie de contacto

ÖA2/A1 = 6.6 Þ Ao = 2000 [cm2]

Pnb = 357000 [kg] Pn < Pnb CUMPLE

Armadura de Transferencia As min = 0.005*Ag = 5.0 [cm2] 3 f 5/8 5/8