Oil API 30

Gas sg 0.65
Water SG 1.05
Water Cut (%) 90%
Gas Oil Ratio (scf/bbl) 73
Design Pro Bottom Hole Temperature (F) 140
Casing 7 inch 26#/ft
Tubing 3.5 inch 9.3#/ft
Example Well Depth TVD (ft) 4590
Pump Depth (ft) 3480
Perfs (ft) 3937
Wellhead Temp (F) 86
Recommend pump PI 3.9
type, # of stages, Reservoir Pressure (psi) 1729
intake, protector, Design Rate 3500
Tubing Pressure 450
motor and cable Casing Pressure 0
Natural Gas Separation 40%
Power 480 V at 60 Hz
Switchgear VSD
Ambient Temp (F) 80

1
Example 2 – With Packer – Create New Well
Data Units Value Data Units Value
Reservoir Press (mid-perfs) Psi 1072 Casing Size to 4150 ft 9.625 in 47 #/ft
Test Q Bpd 2900 Casing Size to 6102 ft 7 in 38 #/ft
Test PWF Psi 600 Wellhead Temp °F 100
Inflow Method Vogel Correct for Reservoir Temp °F 175
WC Gas SG unitless 0.65
Wellhead Pressure psi 200 GOR Scf/stb 400
Water Cut % 85 Solids/Fines Ppm 40
SG (Water) unitless 1.1 H2S % 1.2
Oil Density °API 17 Gas Separation text defined
Tubing Size 4.5 in 12.75 #/ft Packer (not vented) yes 3800 ft
Tubing Length ft 3900 Solid Type Text Very fine
Tubing Thread Text 8RD EUE Target Intake Pressure psi 190
Top Perforations, Measured Ft 4383 System Power Hz 50
Frequency
Mid-Perfs, (Datam) Ft 4731
Measured Ambient Temp °F 65
Bottom Perfs, Measured Ft 5134 Casing Pressure psi 0

2
Example 2 - Deviation Survey
Point Measured Depth Vertical Depth
Integer Ft Ft
1 0 0
2 262 262
3 1181 1178
4 1575 1556
5 1968 1909
6 2264 2147
7 2657 2416
8 3218 2694
9 4708 3100
10 5456 3200
11 5830 3210
12 6102 3215

3
Sensitivities
Rate PI GLR WCT

Rate

Head

HP

4
Evaluation Cases
High Case Low Case

Rate Rate GLR Rate GLR

Head Rate PI GLR Rate PI GLR

HP Rate PI GLR WCT Rate PI GLR WCT

You might also like