DESIGN SYSTEM FOR CONCRETE AND CLAY MASONRY

MASONRY The National Concrete Masonry Association Brick Industry Association


Western States Clay Product Association International Code Council
Free Trial Version (Release 7.2.0)
Not For Design Use

Prjct: Name:
Topic: Date:
Page: Chkd:

Strength Design of a Concrete Masonry Lintel


Using the TMS 402-13 Strength Design Code
A
Specified Wall Construction Data H
8 in Masonry Units
Running Bond Construction
Grout Spacing = 48 in B A
Clear Span = 3 ft - 4.00 in
Bearing Length = 8 in
Height Above Opening = 6 ft - 9.00 in

FREE TRIAL VERSION


Minimum Courses Considered = 1
Maximum Courses Considered = 5
Maximum Number of Bars Considered = Must Fit
NOT FOR DESIGN
Specified Load Data
L

Specified load modification factors


f1 = 0.5
f2 = 0.2
Uniform Joist Point A PointB Point C
Load (lb/ft) (lb) (lb) (lb) (lb) d
h
Dead 0 108 0 0 0
Live 0 628 0 0 0
Roof 0 0 0 0 0
Snow 0 0 0 0 0 X
Rain 0 0 0 0 0
b
So 0 4 0 0 0

FREE TRIAL VERSION


Sl 16 Sect AA
Sw 0

NOT FOR DESIGN


The lintel is considered to be a simply-supported beam when calculating
the design forces using these specified loads.

Parameters for Load Calculations


Le = 47.63 in
Lintel W = 54.72 lb/ft
Wall W = 250.9 lb/ft
Arching was not used
Load combination 1.2(D + F) + 1.6(L + H) + 0.5Lr controlled moment
Load combination 1.2(D + F) + 1.6(L + H) + 0.5Lr controlled shear

Design Forces Used


Vu = 1,716 lbs (Computed from Loads)
Computed M at this V = 13,770 lb-in
Critical Location x = 0.140L
DESIGN SYSTEM FOR CONCRETE AND CLAY MASONRY
MASONRY The National Concrete Masonry Association Brick Industry Association
Western States Clay Product Association International Code Council
Free Trial Version (Release 7.2.0)
Not For Design Use

Prjct: Name:
Topic: Date:
Page: Chkd:

Shear Utilization Ratio = 42.32 percent


Mu = 28,664.7 lb-in (Computed from Loads)
Critical V at this M = 0. lb
Critical Location x = 0.500L

Material Strength Properties


fy = 60,000 psi (Specified)
Mortar: Portland cement lime / Mortar cement Type S, Coarse Grout
f'm = 1,500 psi (Specified)
Em = 900f'm = 1,350,000 psi

FREE TRIAL VERSION


Required Cross-Sectional Dimensions
b = 7.625 in. (Specified)
NOT FOR DESIGN
x = 3.000 in. (Specified)
Cover = 3.000 in. (Specified)
h = 7.625 in. (1 courses used)
d = 4.375 in. (Computed for bars and dimensions specified)

Check Shear Capacity


Maximum Permitted Vu = øVnm = 4,053 lbs without stirrups
Maximum Permitted Vn = 9,007 lbs
OK -- Shear capacity is acceptable

Check Bearing Capacity


Maximum Reaction Force Rb = 2,415 lbs
Bearing Area Ab = 61.00 in2

FREE TRIAL VERSION


Computed Bearing Stress fb = 39.60 psi
Allowable Bearing Stress Fb = 0.6(0.8f'm) = 720.0 psi

NOT FOR DESIGN


Bearing Stress is Acceptable

Compute Required Steel Area

Rn = Mu/0.9bd2 = [28,660/0.9]/[7.625(4.375)2] = 218.2 psi


(2Rn)/(0.8f'm) = [2(218.2)]/[0.8(1500)] = 0.3637
Rhoreq'd = [0.8(1500)/60,000][1-sqrt(1-0.3637)] = 0.004046
Rhomin = (4/3)Rhoreq'd = 0.00540 TMS 402-13 9.3.4.2.2.3
Rhomin = -0.000200 TMS 402-13 9.3.4.2.2.2 (based on 1.3M cr)
Rhomax = 0.00710
Use Rho = 0.00400
As = Rho(bd) = 0.135 sq.in (Required)

Use 1 #4 Bars (As Provided = 0.2 sq.in)


Maximum Mu capacity = 40,170 lb-in (for As provided)
4
DESIGN SYSTEM FOR CONCRETE AND CLAY MASONRY
MASONRY The National Concrete Masonry Association Brick Industry Association
Western States Clay Product Association International Code Council
Free Trial Version (Release 7.2.0)
Not For Design Use

Prjct: Name:
Topic: Date:
Page: Chkd:

Icr = 43.35 in4


Mcr = 14,780 lb-in
fr = 200.0 psi
Ieff = 136.7 in4
Maximum deflection = -0.0258 in.
Maximum allowable deflection at Le/240 = 0.198 in.
Maximum allowable deflection at Le/360 = 0.132 in.
Maximum allowable deflection at Le/600 = 0.0794 in.
Maximum allowable deflection = 0.0794 in. when supporting unreinforced masonry (TMS 402-13 5.2.1.4.1)

FREE TRIAL VERSION


Bending moment envelope Bending moment capacity
with the reinforcement provided

NOT FOR DESIGN

Absolute shearing force envelope Maximum shearing force


without shear reinforcement

FREE TRIAL VERSION


Development and Splice Lengths for Longitudinal Reinforcement
K = 2.5000 in.

NOT FOR DESIGN


Required Development Length: ld = 20.14 in.
Required Lap Splice Length: = 20.14 in.
Some codes may require epoxy-coated reinforcement to have longer development and splice lengths.