This Basis of Design provides documentation for the earthwork activities for the project. It is intended to describe
the project requirements, identify governing codes and criteria being utilized, explain proposed design solutions
and document other situations which affect the design.
The Basis of Design is organized by content and technical design discipline as follows:
VOLUME 1

SECTION 1 ........................................................................................................................................................ CIVIL


SECTION 2 ..................................................................................................................................... ARCHITECTURE
SECTION 3 ......................................................................................................................................... STRUCTURAL
SECTION 4 .............................................................................................................................. MECHANICAL/HVAC

VOLUME 2

SECTION 5 .............................................................................................................................................. PLUMBING


SECTION 6 .................................................................................................................................FIRE PROTECTION
SECTION 7 ...........................................................................................................................................ELECTRICAL
SECTION 8 ................................................................................................................................COMMUNICATIONS
SECTION 9 ................................................................ HOST NATION EXCEPTION TO US STANDARDS LETTER

VOLUME 3 (ELECTRONIC ONLY)

APPENDIX A ........................................................................................................ STRUCTURAL CALCULATIONS


ARCHITECT AND ENGINEERING SERVICES FOR RSLF ARTILLERY BRIGADE, SAUDI ARABIA
SOLICITATION # W912ER19C0001
24th Artillery Brigade Base, Eastern Province, Kingdom of Saudi Arabia

This page intentionally left blank


ARCHITECT AND ENGINEERING SERVICES FOR RSLF ARTILLERY BRIGADE, SAUDI ARABIA
SOLICITATION # W912ER19C0001
24th Artillery Brigade Base, Eastern Province, Kingdom of Saudi Arabia

APPENDIX A
STRUCTURAL
CALCULATIONS
ARCHITECT AND ENGINEERING SERVICES FOR RSLF ARTILLERY BRIGADE, SAUDI ARABIA
CONTRACT #W912ER-14-D-0004; TASK ORDER #0008
24th Artillery Brigade Base, Eastern Province, Kingdom of Saudi Arabia

This page intentionally left blank


TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
Structural Calculations

SECTION PAGE NO.

A Brigade Headquarters………………………………………………………..………………………… A1 - A 94

B Battalion Headquarters……………………………………………………………...………………… B1 - B 82

C Company Headquarters…………………………………………………………...…………………… C1 - C 86

D Guard House……………………………………………………………………………………………… D 1 - D 128

E Fire Pump House……………………………………………………………….………………………… E 1 - E 164

XS Structural Site Design…………………………………………………………….…………………… XS 1 - XS 116


SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
A. Brigade Headquarters

Building Design PAGE NO.

RAM Calculation Check……………………………………………………………………………………… A1 - A2

RAM Modeler………………………………….……..………………………………………………………… A3 - A3

RAM Frame Analysis - Loads and Applied Forces………………………………………………….…..… A 4 - A 25

RAM Concrete Pedestal Design……………………………………….………..…………………………… A 26 - A 29

RAM Concrete Analysis - Wall Forces……………………………………….………..…………………… A 30 - A 38

RAM Concrete Stem Wall……………………………………...…………..………………………………… A 39 - A 59

RAM Foundation - Spread Footing Design………………..……………..………………………………… A 60 - A 60

RAM Foundation - Continuous Footing Design………………..……………..…………………………… A 61 - A 90

Slab on Grade Design…………………………………………….…..……..…….…………………………… A 91 - A 92

CMU Wall Design…………………………………………….…..……..…….………………………………… A 93 - A 94


A1
A2
RAM Structural System V16.00.00.28. - Floor Plan: STEM
DataBase: Brigade Headquarters 04/24/19 10:03:00

21
T

20

38
S 19

37
R
18

36
Q
17

35

P
16

34

N 49
M'
M''
15

33

48

61
M
14

47
32

60
L
10 12

31

45

59
K 11 13
23 40 46 51 53 55
J
58
22

9 39 44 50 52 54
H
43

57
30
8

G
29
7

41

56

F 42
E''
E'
28
6

E
27
5

D
26
4

C
25
3

B
24
1

2 A3
Loads and Applied Forces

RAM Frame 16.00.00.28


DataBase: Brigade Headquarters 04/24/19 10:03:00

LOAD CASE: WIND


ASCE 7-16
Exposure: C
Basic Wind Speed (km/h): 185.0
Apply Directionality Factor, Kd = 0.85
Use Topography Factor, Kzt: 1.00
Ground Elevation Factor, Ke: 1.00
Use Calculated Frequency for X-Dir.
Use Calculated Frequency for Y-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for X-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for Y-Dir.
Damping Ratio for Flexible Structures= 0.01
Mean Roof Height (m): Top Story Height + Parapet = 6.60
Ground Level: Base
WIND PRESSURES:
X-Direction: Natural Frequency = 6.735 Structure is Rigid
Y-Direction: Natural Frequency = 17.867 Structure is Rigid
CpWindward = 0.80 qLeeward (qh) = 1.26 kN/m2
GCpn (Parapet): Windward = 1.50 Leeward = -1.00
Height Kz Kzt qz Gust Factor G CpLeeward Pressure (kN/m2)
m kN/m2 X Y X Y X Y
6.60 0.917 1.000 1.263 ---- ---- ---- ---- 3.157 3.157
5.00 0.865 1.000 1.191 0.850 0.850 -0.500 -0.292 1.346 1.124
6.60 0.917 1.000 1.263 ---- ---- ---- ---- 3.157 3.157
5.00 0.865 1.000 1.191 0.850 0.850 -0.500 -0.292 1.346 1.124
6.60 0.917 1.000 1.263 ---- ---- ---- ---- 3.157 3.157
5.00 0.865 1.000 1.191 0.850 0.850 -0.500 -0.292 1.346 1.124
0.00 0.849 1.000 1.169 0.850 0.850 -0.500 -0.292 1.331 1.108

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_X
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 336.79 0.00 9.63 59.69
ROOF 2 5.00 237.83 0.00 26.39 38.13
ROOF 3 5.00 334.27 0.00 7.91 19.89
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_1_X
Level Ht Fx Fy
m kN kN
ROOF 5.00 908.90 0.00
STEM 1.00 --- ---
_________ A4_________
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 2/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
908.90 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 0.00 99.26 9.63 59.69
ROOF 2 5.00 0.00 164.98 26.39 38.13
ROOF 3 5.00 0.00 126.14 7.91 19.89
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_1_Y
Level Ht Fx Fy
m kN kN
ROOF 5.00 0.00 390.38
STEM 1.00 --- ---
_________ _________
0.00 390.38

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 252.59 0.00 9.63 65.70
ROOF 2 5.00 178.38 0.00 26.39 42.37
ROOF 3 5.00 250.70 0.00 7.91 25.85
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X+E
Level Ht Fx Fy
m kN kN
ROOF 5.00 681.67 0.00
STEM 1.00 --- ---
_________ _________
681.67 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X-E
Level Diaph.# Ht Fx Fy X Y
A5
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 3/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
m kN kN m m
ROOF 1 5.00 252.59 0.00 9.63 53.68
ROOF 2 5.00 178.38 0.00 26.39 33.88
ROOF 3 5.00 250.70 0.00 7.91 13.92
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X-E
Level Ht Fx Fy
m kN kN
ROOF 5.00 681.67 0.00
STEM 1.00 --- ---
_________ _________
681.67 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 0.00 74.45 11.52 59.69
ROOF 2 5.00 0.00 123.74 29.54 38.13
ROOF 3 5.00 0.00 94.60 10.32 19.89
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y+E
Level Ht Fx Fy
m kN kN
ROOF 5.00 0.00 292.79
STEM 1.00 --- ---
_________ _________
0.00 292.79

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y-E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 0.00 74.45 7.73 59.69
ROOF 2 5.00 0.00 123.74 23.23 38.13
ROOF 3 5.00 0.00 94.60 5.50 19.89
STEM --- --- --- --- --- ---

A6
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 4/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y-E
Level Ht Fx Fy
m kN kN
ROOF 5.00 0.00 292.79
STEM 1.00 --- ---
_________ _________
0.00 292.79

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X+Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 252.59 74.45 9.63 59.69
ROOF 2 5.00 178.38 123.74 26.39 38.13
ROOF 3 5.00 250.70 94.60 7.91 19.89
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X+Y
Level Ht Fx Fy
m kN kN
ROOF 5.00 681.67 292.79
STEM 1.00 --- ---
_________ _________
681.67 292.79

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X-Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 252.59 -74.45 9.63 59.69
ROOF 2 5.00 178.38 -123.74 26.39 38.13
ROOF 3 5.00 250.70 -94.60 7.91 19.89
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X-Y
Level Ht Fx Fy
m kN kN
ROOF 5.00 681.67 -292.79
STEM 1.00 --- ---
A7
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 5/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
681.67 -292.79

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 189.45 55.84 7.73 65.70
ROOF 2 5.00 133.78 92.80 23.23 42.37
ROOF 3 5.00 188.03 70.95 5.50 25.85
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Ht Fx Fy
m kN kN
ROOF 5.00 511.26 219.59
STEM 1.00 --- ---
_________ _________
511.26 219.59

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 189.45 55.84 11.52 53.68
ROOF 2 5.00 133.78 92.80 29.54 33.88
ROOF 3 5.00 188.03 70.95 10.32 13.92
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 5.00 511.26 219.59
STEM 1.00 --- ---
_________ _________
511.26 219.59

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CW
A8
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 6/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 189.45 -55.84 11.52 65.70
ROOF 2 5.00 133.78 -92.80 29.54 42.37
ROOF 3 5.00 188.03 -70.95 10.32 25.85
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CW
Level Ht Fx Fy
m kN kN
ROOF 5.00 511.26 -219.59
STEM 1.00 --- ---
_________ _________
511.26 -219.59

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 189.45 -55.84 7.73 53.68
ROOF 2 5.00 133.78 -92.80 23.23 33.88
ROOF 3 5.00 188.03 -70.95 5.50 13.92
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 5.00 511.26 -219.59
STEM 1.00 --- ---
_________ _________
511.26 -219.59

A9
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 7/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

LOAD CASE: SEIS


Seismic ASCE 7-16 Equivalent Lateral Force
Site Class: D Importance Factor: 1.50 Ss: 0.370 g S1: 0.170 g TL: 12.00 s
Fa: 1.504 Fv: 2.260 SDs: 0.371 g SD1: 0.256 g
Risk Category: IV Seismic Design Category: D
Provisions for: Force
Ground Level: Base

Dir Eccent R Ta Equation Building Period-T


X + And - 4.0 Std,Ct=0.020,x=0.75 Use Ta
Y + And - 4.0 Std,Ct=0.020,x=0.75 Use Ta

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
X 0.163 1.444 0.163 0.163 0.139 0.589 0.024 0.139 1.000

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
Y 0.163 1.444 0.163 0.163 0.139 0.589 0.024 0.139 1.000

Total Building Weight (kN) = 29974.25

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 0.00 12.12 54.35
ROOF 2 5.00 1076.49 0.00 28.45 39.30
ROOF 3 5.00 1332.56 0.00 8.89 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 0.00
STEM 1.00 --- ---
_________ _________
4170.02 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_F
Level Diaph.# Ht A10 Fx Fy X Y
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 8/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
m kN kN m m
ROOF 1 5.00 1760.97 0.00 12.12 50.34
ROOF 2 5.00 1076.49 0.00 28.45 36.47
ROOF 3 5.00 1332.56 0.00 8.89 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 0.00
STEM 1.00 --- ---
_________ _________
4170.02 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 0.00 1760.97 12.75 52.35
ROOF 2 5.00 0.00 1076.49 29.50 37.89
ROOF 3 5.00 0.00 1332.56 9.70 21.52
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 0.00 4170.02
STEM 1.00 --- ---
_________ _________
0.00 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 0.00 1760.97 11.49 52.35
ROOF 2 5.00 0.00 1076.49 27.39 37.89
ROOF 3 5.00 0.00 1332.56 8.09 21.52
STEM --- --- --- --- --- ---

A11
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 9/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 0.00 4170.02
STEM 1.00 --- ---
_________ _________
0.00 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 528.29 12.75 54.35
ROOF 2 5.00 1076.49 322.95 29.50 39.30
ROOF 3 5.00 1332.56 399.77 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 1251.01
STEM 1.00 --- ---
_________ _________
4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 -528.29 12.75 54.35
ROOF 2 5.00 1076.49 -322.95 29.50 39.30
ROOF 3 5.00 1332.56 -399.77 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 -1251.01
STEM 1.00 --- ---
A12
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 10/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 528.29 12.75 54.35
ROOF 2 5.00 -1076.49 322.95 29.50 39.30
ROOF 3 5.00 -1332.56 399.77 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 -528.29 12.75 54.35
ROOF 2 5.00 -1076.49 -322.95 29.50 39.30
ROOF 3 5.00 -1332.56 -399.77 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
A13
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 11/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 1760.97 12.75 54.35
ROOF 2 5.00 322.95 1076.49 29.50 39.30
ROOF 3 5.00 399.77 1332.56 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 4170.02
STEM 1.00 --- ---
_________ _________
1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 -1760.97 12.75 54.35
ROOF 2 5.00 322.95 -1076.49 29.50 39.30
ROOF 3 5.00 399.77 -1332.56 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 1760.97 12.75 54.35
ROOF 2 5.00 -322.95 1076.49 29.50 39.30
ROOF 3 5.00 -399.77 1332.56 9.70 23.51
STEM --- --- --- --- --- ---
A14
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 12/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 -1760.97 12.75 54.35
ROOF 2 5.00 -322.95 -1076.49 29.50 39.30
ROOF 3 5.00 -399.77 -1332.56 9.70 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 528.29 11.49 54.35
ROOF 2 5.00 1076.49 322.95 27.39 39.30
ROOF 3 5.00 1332.56 399.77 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 1251.01
STEM 1.00 --- ---
A15
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 13/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 -528.29 11.49 54.35
ROOF 2 5.00 1076.49 -322.95 27.39 39.30
ROOF 3 5.00 1332.56 -399.77 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 528.29 11.49 54.35
ROOF 2 5.00 -1076.49 322.95 27.39 39.30
ROOF 3 5.00 -1332.56 399.77 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
A16
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 14/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 -528.29 11.49 54.35
ROOF 2 5.00 -1076.49 -322.95 27.39 39.30
ROOF 3 5.00 -1332.56 -399.77 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 1760.97 11.49 54.35
ROOF 2 5.00 322.95 1076.49 27.39 39.30
ROOF 3 5.00 399.77 1332.56 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 4170.02
STEM 1.00 --- ---
_________ _________
1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 -1760.97 11.49 54.35
ROOF 2 5.00 322.95 -1076.49 27.39 39.30
ROOF 3 5.00 399.77 -1332.56 8.09 23.51
STEM --- --- --- --- --- ---
A17
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 15/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 1760.97 11.49 54.35
ROOF 2 5.00 -322.95 1076.49 27.39 39.30
ROOF 3 5.00 -399.77 1332.56 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 -1760.97 11.49 54.35
ROOF 2 5.00 -322.95 -1076.49 27.39 39.30
ROOF 3 5.00 -399.77 -1332.56 8.09 23.51
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 -4170.02
STEM 1.00 --- ---
A18
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 16/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
-1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 528.29 12.75 50.34
ROOF 2 5.00 1076.49 322.95 29.50 36.47
ROOF 3 5.00 1332.56 399.77 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 1251.01
STEM 1.00 --- ---
_________ _________
4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 -528.29 12.75 50.34
ROOF 2 5.00 1076.49 -322.95 29.50 36.47
ROOF 3 5.00 1332.56 -399.77 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
A19
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 17/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 528.29 12.75 50.34
ROOF 2 5.00 -1076.49 322.95 29.50 36.47
ROOF 3 5.00 -1332.56 399.77 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 -528.29 12.75 50.34
ROOF 2 5.00 -1076.49 -322.95 29.50 36.47
ROOF 3 5.00 -1332.56 -399.77 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 1760.97 12.75 50.34
ROOF 2 5.00 322.95 1076.49 29.50 36.47
ROOF 3 5.00 399.77 1332.56 9.70 19.54
STEM --- --- --- --- --- ---
A20
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 18/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 4170.02
STEM 1.00 --- ---
_________ _________
1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 -1760.97 12.75 50.34
ROOF 2 5.00 322.95 -1076.49 29.50 36.47
ROOF 3 5.00 399.77 -1332.56 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 1760.97 12.75 50.34
ROOF 2 5.00 -322.95 1076.49 29.50 36.47
ROOF 3 5.00 -399.77 1332.56 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 4170.02
STEM 1.00 --- ---
A21
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 19/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
-1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 -1760.97 12.75 50.34
ROOF 2 5.00 -322.95 -1076.49 29.50 36.47
ROOF 3 5.00 -399.77 -1332.56 9.70 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 528.29 11.49 50.34
ROOF 2 5.00 1076.49 322.95 27.39 36.47
ROOF 3 5.00 1332.56 399.77 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 1251.01
STEM 1.00 --- ---
_________ _________
4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
A22
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 20/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 1760.97 -528.29 11.49 50.34
ROOF 2 5.00 1076.49 -322.95 27.39 36.47
ROOF 3 5.00 1332.56 -399.77 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 528.29 11.49 50.34
ROOF 2 5.00 -1076.49 322.95 27.39 36.47
ROOF 3 5.00 -1332.56 399.77 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -1760.97 -528.29 11.49 50.34
ROOF 2 5.00 -1076.49 -322.95 27.39 36.47
ROOF 3 5.00 -1332.56 -399.77 8.09 19.54
STEM --- --- --- --- --- ---
A23
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 21/22


DataBase: Brigade Headquarters 04/24/19 10:03:00

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -4170.02 -1251.01
STEM 1.00 --- ---
_________ _________
-4170.02 -1251.01

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 1760.97 11.49 50.34
ROOF 2 5.00 322.95 1076.49 27.39 36.47
ROOF 3 5.00 399.77 1332.56 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 4170.02
STEM 1.00 --- ---
_________ _________
1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 528.29 -1760.97 11.49 50.34
ROOF 2 5.00 322.95 -1076.49 27.39 36.47
ROOF 3 5.00 399.77 -1332.56 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 1251.01 -4170.02
STEM 1.00 --- ---
A24
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 22/22


DataBase: Brigade Headquarters 04/24/19 10:03:00
_________ _________
1251.01 -4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 1760.97 11.49 50.34
ROOF 2 5.00 -322.95 1076.49 27.39 36.47
ROOF 3 5.00 -399.77 1332.56 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 4170.02

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 5.00 -528.29 -1760.97 11.49 50.34
ROOF 2 5.00 -322.95 -1076.49 27.39 36.47
ROOF 3 5.00 -399.77 -1332.56 8.09 19.54
STEM --- --- --- --- --- ---

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 5.00 -1251.01 -4170.02
STEM 1.00 --- ---
_________ _________
-1251.01 -4170.02

A25
Concrete Column Design
RAM Concrete Column v16.00.00.28
Database: Brigade Headquarters 05/08/19 08:39:57
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 1 Grid Location: (1-H)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.69
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 422.33
Moment Top Major(kNm) 33.38
Minor(kNm) 44.53
Moment Bottom Major(kNm) -16.47
Minor(kNm) -21.98
Calculated Parameters (Angle = 53.14 degrees): Ld/Cap = 0.43
0.65 Pn(kN): 422.33
0.65 Mn Major(kNm): 76.79 0.65 Mn Minor(kNm): 102.43
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 422.33 422.33
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28
TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
A26
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 2/4
Database: Brigade Headquarters 05/08/19 08:39:57
Building Code: IBC Concrete Code: ACI 318-14
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 1 83.48 148.48 162.06 0.75 232.91 0.36
1 Minor: 1 83.48 148.48 162.06 0.75 232.91 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 186.90 83.48 186.90 83.48
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

A27
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 3/4
Database: Brigade Headquarters 05/08/19 08:39:57
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 2 Grid Location: (0.00m-39.65m)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.68
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 412.21
Moment Top Major(kNm) 31.43
Minor(kNm) -44.10
Moment Bottom Major(kNm) -15.50
Minor(kNm) 21.91
Calculated Parameters (Angle = 54.52 degrees): Ld/Cap = 0.43
0.65 Pn(kN): 412.21
0.65 Mn Major(kNm): 73.87 0.65 Mn Minor(kNm): 103.65
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 412.21 412.21
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28
TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
A28
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 4/4
Database: Brigade Headquarters 05/08/19 08:39:57
Building Code: IBC Concrete Code: ACI 318-14
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 1 83.04 147.91 162.06 0.75 232.48 0.36
1 Minor: 1 83.04 147.91 162.06 0.75 232.48 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 185.68 83.04 185.68 83.04
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

A29
Wall Forces
RAM Concrete Analysis v16.00.00.28
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14

Story: ROOF
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 353.48 26.87 -45.26 0.05 0.19
Roof Live Load 26.18 3.50 -4.49 0.02 -0.03

2 Dead Load 533.65 34.74 16.46 0.66 -3.53


Roof Live Load 15.31 4.29 2.09 0.06 -0.30

3 Dead Load 556.37 8.22 4.07 0.00 0.03


Roof Live Load 44.83 0.83 0.18 0.00 0.00

4 Dead Load 560.03 6.43 11.34 0.00 0.00


Roof Live Load 45.37 0.58 0.77 0.00 0.00

5 Dead Load 591.92 36.11 -5.03 0.00 0.00


Roof Live Load 51.93 6.60 -2.60 0.00 0.00

6 Dead Load 714.26 35.78 -3.79 0.00 0.00


Roof Live Load 76.95 6.54 -2.30 0.00 0.00

7 Dead Load 720.89 -16.13 25.10 0.00 0.00


Roof Live Load 77.39 -4.94 4.35 0.00 0.00

8 Dead Load 496.42 7.68 32.68 0.09 0.49


Roof Live Load 43.00 -0.76 5.44 0.00 0.06

9 Dead Load 127.71 9.43 15.50 -0.07 0.47


Roof Live Load 10.03 0.56 1.02 -0.01 0.05

10 Dead Load 44.56 -3.72 -3.50 -0.02 0.11


Roof Live Load 2.60 -0.20 -0.20 0.00 0.00

11 Dead Load 109.94 3.09 7.61 -0.06 0.77


Roof Live Load 6.64 0.39 0.76 -0.01 0.07

12 Dead Load 315.38 -2.15 -45.25 0.06 0.06


Roof Live Load 23.53 0.52 -4.35 0.02 -0.04

13 Dead Load 381.93 19.86 14.22 0.20 -0.93


Roof Live Load 12.01 2.12 1.52 0.02 -0.08

14 Dead Load 556.15 1.16 -11.76 0.00 0.02


Roof Live Load 44.76 0.31 -1.17 0.00 -0.00

15 Dead Load 559.62 A30 -1.26 -1.75 0.00 0.00


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 2/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 45.28 -0.10 -0.14 -0.00 -0.00

16 Dead Load 559.19 -0.77 -1.45 0.00 0.00


Roof Live Load 45.24 -0.06 -0.10 -0.00 -0.00

17 Dead Load 532.29 -0.69 -1.40 0.00 0.00


Roof Live Load 43.06 -0.05 -0.10 0.00 0.00

18 Dead Load 586.28 -0.49 -1.47 0.00 0.00


Roof Live Load 47.43 -0.03 -0.10 0.00 0.00

19 Dead Load 559.27 -0.11 2.47 0.00 0.01


Roof Live Load 45.19 -0.04 0.31 0.00 0.00

20 Dead Load 499.00 -57.75 56.96 0.03 0.22


Roof Live Load 37.95 -7.16 5.57 0.01 -0.03

21 Dead Load 542.16 15.43 5.38 -0.71 3.57


Roof Live Load 16.07 1.75 0.63 -0.06 0.31

22 Dead Load 580.13 -47.10 28.17 0.49 -3.94


Roof Live Load 42.29 -6.07 3.96 0.04 -0.31

23 Dead Load 545.30 513.12 -52.31 -0.07 0.69


Roof Live Load 27.92 50.81 -5.69 -0.01 0.05

24 Dead Load 358.82 23.02 -44.13 0.00 -0.27


Roof Live Load 26.83 3.05 -4.31 -0.01 0.02

25 Dead Load 556.71 7.45 3.52 -0.00 -0.03


Roof Live Load 44.88 0.77 0.18 -0.00 -0.00

26 Dead Load 560.03 5.98 10.44 -0.00 -0.00


Roof Live Load 45.37 0.56 0.72 -0.00 -0.00

27 Dead Load 591.86 35.59 -5.94 -0.00 -0.00


Roof Live Load 51.93 6.57 -2.65 0.00 0.00

28 Dead Load 713.80 34.76 -5.25 0.00 0.00


Roof Live Load 76.89 6.45 -2.41 0.00 0.00

29 Dead Load 729.10 -9.75 9.83 0.00 0.01


Roof Live Load 78.38 -4.15 2.58 0.00 0.00

30 Dead Load 702.85 82.00 -25.79 -0.00 0.12


A31
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 3/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 64.50 6.05 -1.17 -0.00 0.01

31 Dead Load 319.46 -3.26 -42.27 -0.00 -0.15


Roof Live Load 23.95 0.40 -4.04 -0.01 0.03

32 Dead Load 556.66 1.93 -8.88 -0.00 -0.02


Roof Live Load 44.81 0.40 -0.88 -0.00 0.00

33 Dead Load 559.62 -0.01 0.77 -0.00 -0.00


Roof Live Load 45.28 0.03 0.12 0.00 0.00

34 Dead Load 559.19 0.48 1.04 -0.00 -0.00


Roof Live Load 45.24 0.07 0.15 0.00 0.00

35 Dead Load 532.28 0.50 0.98 -0.00 -0.00


Roof Live Load 43.06 0.07 0.15 -0.00 -0.00

36 Dead Load 586.28 0.82 1.15 -0.00 -0.00


Roof Live Load 47.43 0.11 0.17 -0.00 -0.00

37 Dead Load 559.32 1.19 4.88 -0.00 -0.01


Roof Live Load 45.20 0.09 0.56 -0.00 -0.00

38 Dead Load 501.62 -53.43 58.54 -0.02 -0.24


Roof Live Load 38.25 -6.68 5.72 -0.01 0.03

39 Dead Load 530.37 -18.64 -39.49 0.05 -0.19


Roof Live Load 50.64 -0.52 -5.05 0.01 -0.07

40 Dead Load 539.25 -5.94 -46.41 -0.09 0.29


Roof Live Load 51.58 0.82 -5.77 -0.02 0.08

41 Dead Load 213.07 -81.61 12.16 -0.35 1.66


Roof Live Load 7.49 -7.97 1.67 -0.03 0.14

42 Dead Load 1219.18 -10.83 -5.49 -0.10 -0.25


Roof Live Load 91.16 -0.94 -0.50 -0.02 0.05

43 Dead Load 207.62 65.10 -31.37 -0.18 0.78


Roof Live Load 14.29 8.62 -5.21 -0.02 0.11

44 Dead Load 359.60 38.29 -39.90 0.03 -0.03


Roof Live Load 39.46 5.20 -5.35 0.01 -0.03

45 Dead Load 193.62 -41.70 33.39 -0.27 1.03


A32
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 4/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 14.53 -5.27 5.28 -0.03 0.14

46 Dead Load 392.98 44.40 -47.19 -0.05 0.08


Roof Live Load 42.97 5.84 -6.12 -0.01 0.03

47 Dead Load 140.71 -4.24 6.33 -0.00 0.16


Roof Live Load 2.02 -0.73 1.02 -0.00 0.02

48 Dead Load 164.30 40.47 -19.03 -0.40 1.78


Roof Live Load 7.63 3.83 -2.62 -0.04 0.15

49 Dead Load 1398.54 -11.05 -5.51 0.13 0.15


Roof Live Load 110.05 -0.99 -0.50 0.03 -0.06

50 Dead Load 458.53 2.61 -10.02 0.00 -0.01


Roof Live Load 52.66 0.36 -1.29 0.00 -0.00

51 Dead Load 508.20 3.03 -11.65 -0.00 0.01


Roof Live Load 57.89 0.41 -1.46 -0.00 0.00

52 Dead Load 457.52 -1.60 14.84 0.00 0.00


Roof Live Load 52.47 -0.23 1.98 0.00 -0.00

53 Dead Load 507.28 -1.81 16.81 -0.00 -0.00


Roof Live Load 57.71 -0.26 2.19 -0.00 0.00

54 Dead Load 329.31 -34.64 77.65 0.01 -0.04


Roof Live Load 35.37 -4.89 9.90 0.00 -0.01

55 Dead Load 362.32 -39.60 87.19 -0.02 0.06


Roof Live Load 38.84 -5.42 10.90 -0.00 0.01

56 Dead Load 209.53 -82.06 14.58 0.34 -1.74


Roof Live Load 7.14 -8.05 2.09 0.03 -0.15

57 Dead Load 175.01 49.75 -20.89 0.36 -2.51


Roof Live Load 9.64 6.69 -2.86 0.04 -0.30

58 Dead Load 268.76 9.11 -1.83 0.85 -5.37


Roof Live Load 19.93 0.96 -0.19 0.10 -0.64

59 Dead Load 162.82 -35.44 23.14 0.47 -2.84


Roof Live Load 10.11 -4.62 3.04 0.06 -0.34

60 Dead Load 137.05 -1.11 2.18 0.00 -0.35


A33
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 5/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 1.60 -0.38 0.36 0.00 -0.04

61 Dead Load 162.96 39.51 -18.75 0.38 -1.77


Roof Live Load 7.52 3.73 -2.60 0.03 -0.15

Story: STEM
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 365.61 34.88 -17.96 -0.89 2.11
Roof Live Load 24.82 4.40 -1.71 -0.04 0.07

2 Dead Load 643.22 28.37 -0.37 2.73 -7.24


Roof Live Load 19.60 3.47 -0.04 0.19 -0.50

3 Dead Load 578.55 13.54 -4.28 -0.00 -0.00


Roof Live Load 43.92 1.54 -0.44 -0.00 -0.00

4 Dead Load 592.00 2.89 -0.88 0.00 -0.00


Roof Live Load 45.68 0.59 -0.16 0.00 -0.00

5 Dead Load 629.84 35.92 -6.32 -0.00 -0.00


Roof Live Load 53.43 7.35 -1.30 0.00 -0.00

6 Dead Load 736.18 33.81 -5.69 -0.00 -0.00


Roof Live Load 75.12 6.84 -1.15 0.00 -0.00

7 Dead Load 746.36 -22.18 4.17 -0.01 0.00


Roof Live Load 75.70 -6.18 1.12 -0.00 0.00

8 Dead Load 517.93 -7.74 13.75 -1.31 4.27


Roof Live Load 43.62 -2.82 1.86 -0.11 0.32

9 Dead Load 133.46 0.79 -0.39 -0.18 0.62


Roof Live Load 10.19 0.02 0.08 -0.03 0.09

10 Dead Load 47.39 0.43 2.60 -1.10 3.22


Roof Live Load 2.65 0.03 0.15 -0.06 0.19

11 Dead Load 108.97 -0.86 -3.62 -0.80 2.78


Roof Live Load 6.27 -0.02 -0.23 -0.06 0.20

12 Dead Load 330.13 9.35 -16.05 -0.79 1.79


Roof Live Load 22.78 1.67 -1.47 -0.04 0.07

13 Dead Load 451.96 A34 13.47 -0.18 0.95 -2.59


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 6/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 15.32 1.43 -0.02 0.07 -0.18

14 Dead Load 578.75 13.29 -4.62 -0.00 -0.01


Roof Live Load 43.85 1.61 -0.49 -0.00 -0.00

15 Dead Load 589.84 0.10 -0.29 0.00 -0.00


Roof Live Load 45.23 0.03 -0.03 0.00 -0.00

16 Dead Load 589.80 -0.05 -0.01 -0.00 -0.00


Roof Live Load 45.24 -0.00 0.00 -0.00 -0.00

17 Dead Load 561.43 0.02 -0.02 0.00 -0.00


Roof Live Load 43.06 0.00 -0.00 0.00 -0.00

18 Dead Load 618.30 0.08 0.00 0.00 0.00


Roof Live Load 47.43 0.00 -0.00 0.00 0.00

19 Dead Load 585.97 -5.25 1.85 0.00 -0.00


Roof Live Load 44.77 -0.62 0.19 -0.00 -0.00

20 Dead Load 515.28 -72.47 19.26 -0.92 2.14


Roof Live Load 36.20 -8.80 1.84 -0.04 0.08

21 Dead Load 652.30 13.64 -0.18 -2.74 7.28


Roof Live Load 20.39 1.54 -0.02 -0.18 0.50

22 Dead Load 606.81 -63.87 6.10 2.52 -6.14


Roof Live Load 41.68 -8.12 0.96 0.19 -0.47

23 Dead Load 603.76 407.73 4.64 -0.45 1.08


Roof Live Load 29.85 39.80 0.24 -0.03 0.07

24 Dead Load 371.39 31.36 -17.42 0.93 -2.17


Roof Live Load 25.52 3.97 -1.65 0.04 -0.08

25 Dead Load 579.30 12.71 -4.14 0.00 0.00


Roof Live Load 44.02 1.44 -0.42 0.00 0.00

26 Dead Load 592.00 2.85 -0.86 -0.00 0.00


Roof Live Load 45.68 0.58 -0.16 -0.00 0.00

27 Dead Load 629.73 35.86 -6.23 0.00 0.00


Roof Live Load 53.42 7.34 -1.29 0.00 0.00

28 Dead Load 736.27 34.42 -5.69 -0.00 -0.00


A35
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 7/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 75.14 6.91 -1.16 -0.00 -0.00

29 Dead Load 766.30 1.08 0.02 0.00 0.00


Roof Live Load 78.11 -3.40 0.57 0.00 0.00

30 Dead Load 722.22 64.98 11.81 -0.00 -0.00


Roof Live Load 64.80 4.10 1.46 -0.00 -0.00

31 Dead Load 334.48 7.43 -15.68 0.81 -1.82


Roof Live Load 23.24 1.46 -1.43 0.04 -0.07

32 Dead Load 579.65 12.36 -4.47 0.01 0.01


Roof Live Load 43.94 1.51 -0.47 0.00 0.00

33 Dead Load 589.87 0.06 -0.28 -0.00 0.00


Roof Live Load 45.23 0.02 -0.03 -0.00 0.00

34 Dead Load 589.80 -0.05 -0.01 0.00 0.00


Roof Live Load 45.24 -0.00 -0.00 0.00 0.00

35 Dead Load 561.42 0.02 -0.02 -0.00 0.00


Roof Live Load 43.06 0.00 -0.00 -0.00 0.00

36 Dead Load 618.29 0.09 0.01 -0.00 -0.00


Roof Live Load 47.43 0.00 -0.00 -0.00 -0.00

37 Dead Load 586.12 -5.06 1.83 -0.00 0.00


Roof Live Load 44.79 -0.60 0.18 0.00 0.00

38 Dead Load 518.22 -69.34 18.98 0.94 -2.17


Roof Live Load 36.53 -8.45 1.81 0.04 -0.08

39 Dead Load 581.83 14.73 -15.15 -0.72 1.64


Roof Live Load 52.06 2.89 -1.57 -0.05 0.09

40 Dead Load 593.61 31.36 -17.14 0.70 -1.59


Roof Live Load 53.30 4.64 -1.77 0.04 -0.08

41 Dead Load 273.10 -81.58 2.47 -1.18 3.21


Roof Live Load 10.35 -7.46 0.39 -0.08 0.21

42 Dead Load 1269.09 -8.48 0.10 1.52 -3.52


Roof Live Load 87.58 -0.71 0.01 0.07 -0.13

43 Dead Load 263.21 81.89 -12.82 -0.29 0.93


A36
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 8/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 18.09 10.88 -2.00 -0.05 0.15

44 Dead Load 339.62 55.31 -20.53 -0.21 0.49


Roof Live Load 35.54 7.15 -2.67 -0.01 0.03

45 Dead Load 242.33 -57.73 12.71 -0.39 1.26


Roof Live Load 17.92 -7.42 1.95 -0.06 0.18

46 Dead Load 368.79 63.70 -23.69 0.21 -0.49


Roof Live Load 38.60 8.03 -3.00 0.01 -0.03

47 Dead Load 192.23 -12.50 3.45 0.02 -0.01


Roof Live Load 4.67 -2.08 0.54 0.00 -0.00

48 Dead Load 201.60 46.30 -6.61 -1.33 3.61


Roof Live Load 9.13 4.53 -0.92 -0.09 0.26

49 Dead Load 1440.23 -8.90 0.10 -1.55 3.64


Roof Live Load 105.61 -0.79 0.01 -0.07 0.14

50 Dead Load 452.56 10.05 -6.03 -0.00 0.00


Roof Live Load 50.21 1.32 -0.78 -0.00 0.00

51 Dead Load 499.36 11.71 -7.00 0.00 -0.00


Roof Live Load 55.13 1.49 -0.89 0.00 -0.00

52 Dead Load 447.57 -13.31 8.45 0.00 -0.00


Roof Live Load 49.51 -1.77 1.10 -0.00 -0.00

53 Dead Load 494.30 -15.02 9.53 -0.00 0.00


Roof Live Load 54.43 -1.95 1.21 -0.00 0.00

54 Dead Load 308.78 -61.46 27.82 0.04 -0.11


Roof Live Load 31.45 -7.97 3.46 0.01 -0.01

55 Dead Load 337.50 -69.53 31.30 -0.05 0.13


Roof Live Load 34.47 -8.82 3.83 -0.01 0.02

56 Dead Load 266.72 -87.09 2.51 1.17 -3.19


Roof Live Load 9.58 -8.31 0.44 0.07 -0.21

57 Dead Load 228.82 64.56 -15.98 1.62 -4.05


Roof Live Load 13.09 8.41 -2.05 0.17 -0.43

58 Dead Load 348.86 10.61 -1.69 3.45 -8.71


A37
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 9/9
Database: Brigade Headquarters 05/06/19 14:55:27
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 26.03 1.12 -0.17 0.37 -0.93

59 Dead Load 210.54 -47.97 16.13 1.82 -4.59


Roof Live Load 13.29 -6.07 2.04 0.20 -0.49

60 Dead Load 184.73 -4.33 2.74 -0.02 0.02


Roof Live Load 3.67 -0.94 0.39 -0.00 0.00

61 Dead Load 200.01 45.66 -6.35 1.32 -3.59


Roof Live Load 8.99 4.47 -0.90 0.09 -0.25

A38
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14

Section Cut ID: SC1H:601 (Horizontal)


Story: STEM
Ag = 231813 cm2 Imaj = 235139867212 Imin = 111660849163
cm4 cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:601A
SC1H:601O

SC1H:601C
SC1H:601B SC1H:601N
SC1H:601M
SC1H:601L

SC1H:601D SC1H:601K

Min

SC1H:601ESC1H:601F
SC1H:601G
SC1H:601H
SC1H:601I
SC1H:601J
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.027 OK
Pu = 9100.19 kN phiPn = 338578.88 kN
Mu = 5228.7 kNm at Beta = 64.8 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:601A:
Length = 6.48 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 181.0 kN phiVn = 3446.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:601B:
Length = 4.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 140.4 kN phiVnA39
= 2315.5 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:601C:
Length = 6.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 149.0 kN phiVn = 3193.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:601D:
Length = 14.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 293.8 kN phiVn = 7638.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:601E:
Length = 6.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 131.1 kN phiVn = 3193.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:601F:
Length = 4.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 129.6 kN phiVn = 2315.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:601G:
Length = 5.03 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 116.3 kN phiVn = 2674.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:601H:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 116.8 kN phiVn = 1929.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5
A40
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 3/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Segment SC1H:601I:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 119.5 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:601J:
Length = 3.85 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 94.8 kN phiVn = 2049.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:601K:
Length = 14.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 319.0 kN phiVn = 7638.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:601L:
Length = 3.85 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 112.8 kN phiVn = 2049.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E20 (LC 94)
Code Ref: 11.5.4.5

Segment SC1H:601M:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 148.4 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:601N:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 126.4 kN phiVn = 1929.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:601O:
Length = 6.48 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
A41
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 4/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Vu = 193.2 kN phiVn = 3446.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.541% (11.6.2) OK
Segment SC1H:601A:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601B:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601C:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601D:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601E:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601F:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601G:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: A42284 mm (25.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 5/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601H:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601I:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601J:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601K:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601L:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601M:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601N:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:601O:
A43
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 6/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

A44
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 7/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14

Section Cut ID: SC1H:602 (Horizontal)


Story: STEM
Ag = 220625 cm2 Imaj = 328411866617 Imin = 74691880674 cm4
cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:602JSC1H:602K
SC1H:602I SC1H:602LSC1H:602M
SC1H:602N
SC1H:602O SC1H:602S
SC1H:602P
SC1H:602Q
SC1H:602R

SC1H:602H

Min

SC1H:602F
SC1H:602G SC1H:602E
SC1H:602D
SC1H:602C
SC1H:602B
SC1H:602A
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.040 OK
Pu = 14153.14 kN phiPn = 351200.25 kN
Mu = 36414.7 kNm at Beta = -2.4 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:602A:
Length = 4.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 79.9 kN phiVn = 2315.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:602B:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 118.7 kN phiVnA45
= 2768.0 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 8/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:602C:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 137.9 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:602D:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 139.7 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:602E:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 131.2 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:602F:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 127.2 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:602G:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 144.9 kN phiVn = 2115.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E28 (LC 102)
Code Ref: 11.5.4.5

Segment SC1H:602H:
Length = 12.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 771.3 kN phiVn = 6600.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E30 (LC 104)
Code Ref: 11.5.4.5
A46
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 9/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Segment SC1H:602I:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 158.5 kN phiVn = 2115.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:602J:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 118.3 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:602K:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 116.1 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:602L:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 125.6 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E20 (LC 94)
Code Ref: 11.5.4.5

Segment SC1H:602M:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 122.4 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E20 (LC 94)
Code Ref: 11.5.4.5

Segment SC1H:602N:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 141.5 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:602O:
Length = 3.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
A47
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 10/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Vu = 155.4 kN phiVn = 2076.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:602P:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@200 mm oc
Vu = 50.2 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E13 (LC 87)
Code Ref: 11.5.4.5

Segment SC1H:602Q:
Length = 5.18 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 152.2 kN phiVn = 2754.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5

Segment SC1H:602R:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@200 mm oc
Vu = 73.7 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:602S:
Length = 0.48 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 21.2 kN phiVn = 324.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.069% (11.6.2) OK
Segment SC1H:602A:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3)
A48 OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 11/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602C:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602F:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602H:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
A49
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 12/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602P:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.792% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602R:
A50
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 13/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.792% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK
Segment SC1H:602S:
Max Vert Bar Spacing Limit: 158 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (18.10.2.2) OK

A51
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 14/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14

Section Cut ID: SC1H:603 (Horizontal)


Story: STEM
Ag = 230375 cm2 Imaj = 370834075345 Imin = 80627114127 cm4
cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:603A
SC1H:603B SC1H:603D
SC1H:603C SC1H:603ESC1H:603FSC1H:603G
SC1H:603H

SC1H:603I

Min

SC1H:603Q
SC1H:603P SC1H:603N
SC1H:603O SC1H:603M
SC1H:603LSC1H:603K
SC1H:603J
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.039 OK
Pu = 13159.35 kN phiPn = 336180.72 kN
Mu = 18136.4 kNm at Beta = 0.0 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:603A:
Length = 3.37 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 180.3 kN phiVn = 1796.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E30 (LC 104)
Code Ref: 11.5.4.5

Segment SC1H:603B:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 147.6 kN phiVnA52
= 2768.0 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 15/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:603C:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 131.3 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:603D:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 133.2 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:603E:
Length = 4.95 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 126.8 kN phiVn = 2634.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:603F:
Length = 5.45 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 139.7 kN phiVn = 2901.1 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:603G:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 139.2 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:603H:
Length = 5.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 196.2 kN phiVn = 2821.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5
A53
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 16/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Segment SC1H:603I:
Length = 12.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 837.1 kN phiVn = 6600.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:603J:
Length = 5.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 229.3 kN phiVn = 2821.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:603K:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 172.6 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:603L:
Length = 5.45 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 174.1 kN phiVn = 2901.1 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:603M:
Length = 4.95 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 157.9 kN phiVn = 2634.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:603N:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 165.8 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:603O:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
A54
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 17/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Shear Results:
Vu = 164.3 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E28 (LC 102)
Code Ref: 11.5.4.5

Segment SC1H:603P:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 188.6 kN phiVn = 2768.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E28 (LC 102)
Code Ref: 11.5.4.5

Segment SC1H:603Q:
Length = 3.37 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 202.5 kN phiVn = 1796.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.536% (11.6.2) OK
Segment SC1H:603A:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603B:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603C:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603D:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603E: A55
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 18/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603F:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603G:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603H:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603I:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603J:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603K:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603L:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
A56
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 19/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603M:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603N:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603O:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603P:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:603Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.528% Actual: 0.528% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

A57
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 20/487
Database: Brigade Headquarters 05/06/19 15:44:38
Design Code: ACI 318-14

Section Cut ID: SC1H:604 (Horizontal)


Story: STEM
Ag = 231813 cm2 Imaj = 235139867212 Imin = 111660849163
cm4 cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:604A
SC1H:604O

SC1H:604C
SC1H:604B SC1H:604N
SC1H:604M
SC1H:604L

SC1H:604D SC1H:604K

Min

SC1H:604ESC1H:604F
SC1H:604G
SC1H:604H
SC1H:604I
SC1H:604J
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.027 OK
Pu = 9033.78 kN phiPn = 338578.88 kN
Mu = 5318.6 kNm at Beta = 64.5 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:604A:
Length = 6.48 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 166.7 kN phiVn = 3446.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:604B:
Length = 4.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@300 mm oc Horiz Bar Pat: #5@300 mm oc
Vu = 146.5 kN phiVnA58
= 2315.5 kN OK
Wall Panel Reinforcing
RAM Concrete Shearwall 16.00.00.28
Database: Brigade Headquarters 05/07/19 12:53:03
Design Code: ACI 318-14

Wall Design Group: 1


Bar Pattern Template: 250mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 147 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
148 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
149 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
150 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
151 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
152 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
153 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
154 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
155 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
156 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
157 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
158 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
159 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
160 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
161 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
162 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
163 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%

Wall Design Group: 2


Bar Pattern Template: 200mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 164 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%
165 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%

Wall Design Group: 3


Bar Pattern Template: 150mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 166 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%
167 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%

A59
Spread Footing Design Summary
RAM Foundation v16.00.00.28
DataBase: Brigade Headquarters Date: 05/07/19 13:05:05
Building Code: IBC Design Code: ACI318-14

Orientation Dimensions (m) f'c/fy Bottom Reinforcement Top Reinforcement


Grid Col/Foot Length Width Thick N/mm2 Parallel to Parallel to Parallel to Parallel to
Length Width Length Width
(0.00 - 39.65) 0.00/ 0.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
(1 - H) 0.00/ 0.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
* - Number between () in reinforcement is quantity of bars in center strip of rectangular footing

A60
Continuous Foundation Design
RAM Foundation v16.00.00.28
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 14
Length (m): 15.25
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 7.60 H/S 7-#6
2 7.60/15.25 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.65 H/S 7-#6
2 5.65/ 9.60 S/S 7-#6
3 9.60/15.25 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/15.10 None 43-#6
3 15.10/15.25 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(22.43, 24.10) to (36.77, 24.10) 7.63 14350.01x250.01 Wall 0.00
CONCRETE CAPACITY
A61
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 2/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 7.75 156 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 5.96 155 14.80 494.15 1 0.15
Provided Pos. Moment (kNm) 333.80 14.80 1965.34 0.15
Req. Max Neg. Moment (kNm) -0.00 144 0.00 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 0.00 -0.00 0.00
Req. Max Punching Shear (kN) 1772.30 1 7.63
Provided Punching Shear (kN) 10007.02 7.63
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 75.3 Ld Co # 509
Max Average Unfactored Soil Bearing (kN/m2) 48.6

A62
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 3/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 18
Length (m): 28.95
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.45 H/S 7-#6
2 3.45/15.55 S/S 7-#6
3 15.55/26.56 S/S 7-#6
4 26.56/28.95 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 9.80 H/S 7-#6
2 9.80/23.46 S/S 7-#6
3 23.46/28.95 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.45 None 18-#6
3 6.45/10.80 None 13-#6
4 10.80/15.80 None 15-#6
5 15.80/19.45 None 11-#6
6 19.45/24.66 None 15-#6
7 24.66/28.81 None 12-#6
8 28.81/28.95 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.

A63
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 4/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(36.77, 24.10) to (36.77, 30.10) 3.45 5999.99x250.01 Wall 0.00
(36.77, 30.10) to (36.77, 34.45) 8.63 4350.00x250.01 Wall 0.00
(36.77, 34.45) to (36.77, 39.48) 13.31 5025.01x250.01 Wall 0.00
(36.77, 39.48) to (36.77, 43.10) 17.64 3625.01x250.01 Wall 0.00
(36.77, 43.10) to (36.77, 48.30) 22.05 5199.99x250.01 Wall 0.00
(36.77, 48.30) to (36.77, 52.15) 26.58 3850.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 9.48 142 28.91
Provided Shear (kN) 0.00 28.91
Req. Max Pos. Moment (kNm) 42.04 304 6.45 133.12 159 0.15
Provided Pos. Moment (kNm) 333.80 6.45 822.79 0.15
Req. Max Neg. Moment (kNm) -129.99 150 24.65 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 24.65 -0.00 0.00
Req. Max Punching Shear (kN) 547.26 159 3.45
Provided Punching Shear (kN) 5071.70 3.45
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 44.0 Ld Co # 519
Max Average Unfactored Soil Bearing (kN/m2) 39.3

A64
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 5/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 17
Length (m): 15.25
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 7.60 H/S 7-#6
2 7.60/15.25 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.65 H/S 7-#6
2 5.65/ 9.60 S/S 7-#6
3 9.60/15.25 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/15.10 None 43-#6
3 15.10/15.25 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(22.43, 52.15) to (36.77, 52.15) 7.63 14350.01x250.01 Wall 0.00
CONCRETE CAPACITY
A65
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 6/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 8.35 141 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 6.58 138 14.80 545.70 1 0.15
Provided Pos. Moment (kNm) 333.80 14.80 1965.34 0.15
Req. Max Neg. Moment (kNm) -0.00 11 15.25 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 15.25 -0.00 0.00
Req. Max Punching Shear (kN) 2012.66 1 7.63
Provided Punching Shear (kN) 10007.02 7.63
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 83.4 Ld Co # 506
Max Average Unfactored Soil Bearing (kN/m2) 53.1

A66
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 7/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 15
Length (m): 11.25
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.45 H/S 7-#6
2 3.45/ 8.60 S/S 7-#6
3 8.60/11.25 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.25 H/S 7-#6
2 6.25/11.25 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.45 None 18-#6
3 6.45/11.10 None 14-#6
4 11.10/11.25 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(22.43, 24.10) to (22.43, 30.10) 3.45 5999.99x250.01 Wall 0.00
(22.43, 30.10) to (22.43, 34.45) 8.63 4350.00x250.01 Wall 0.00
A67
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 8/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 12.41 142 11.21
Provided Shear (kN) 0.00 11.21
Req. Max Pos. Moment (kNm) 10.35 142 10.80 134.92 153 0.15
Provided Pos. Moment (kNm) 333.80 10.80 822.79 0.15
Req. Max Neg. Moment (kNm) -22.39 156 6.45 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 6.45 -0.00 0.00
Req. Max Punching Shear (kN) 544.88 153 3.45
Provided Punching Shear (kN) 5071.70 3.45
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 46.8 Ld Co # 506
Max Average Unfactored Soil Bearing (kN/m2) 40.9

A68
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 9/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 16
Length (m): 13.58
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 4.85 H/S 7-#6
2 4.85/11.20 S/S 7-#6
3 11.20/13.58 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 8.20 H/S 7-#6
2 8.20/13.58 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 4.08 None 12-#6
3 4.08/ 9.28 None 15-#6
4 9.28/13.40 None 12-#6
5 13.40/13.58 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(22.43, 39.48) to (22.43, 43.10) 2.26 3625.01x250.01 Wall 0.00
(22.43, 43.10) to (22.43, 48.30) 6.68
A69 5199.99x250.01 Wall 0.00
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 10/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(22.43, 48.30) to (22.43, 52.15) 11.20 3850.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 12.25 159 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 10.03 159 0.45 114.20 1 4.08
Provided Pos. Moment (kNm) 333.80 0.45 685.55 4.08
Req. Max Neg. Moment (kNm) -69.96 160 9.28 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 9.28 -0.00 0.00
Req. Max Punching Shear (kN) 424.34 159 2.26
Provided Punching Shear (kN) 3702.16 2.26
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 45.8 Ld Co # 523
Max Average Unfactored Soil Bearing (kN/m2) 39.8

A70
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 11/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 13
Length (m): 21.73
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.70 H/S 7-#6
2 3.70/ 8.70 S/S 7-#6
3 8.70/12.30 S/S 7-#6
4 12.30/15.90 S/S 7-#6
5 15.90/19.50 S/S 7-#6
6 19.50/21.73 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 7.15 H/S 7-#6
2 7.15/10.40 S/S 7-#6
3 10.40/14.10 S/S 7-#6
4 14.10/17.80 S/S 7-#6
5 17.80/21.73 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.93 None 20-#6
3 6.93/10.50 None 11-#6
4 10.50/14.10 None 11-#6
5 14.10/17.70 None 11-#6
6 17.70/21.56 None 11-#6
7 21.56/21.73 None 1-#6

Longitudinal Shear Reinforcement: A71


Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 12/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(15.95, 34.45) to (22.43, 34.45) 3.69 6474.99x250.01 Wall 0.00
(22.43, 34.45) to (26.00, 34.45) 8.71 3575.00x150.01 Wall 0.00
(26.00, 34.45) to (29.60, 34.45) 12.30 3599.99x150.01 Wall 0.00
(29.60, 34.45) to (33.20, 34.45) 15.90 3599.99x150.01 Wall 0.00
(33.20, 34.45) to (36.77, 34.45) 19.49 3575.00x150.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 16.38 1 21.69
Provided Shear (kN) 0.00 21.69
Req. Max Pos. Moment (kNm) 252.46 24 14.10 228.78 1 0.15
Provided Pos. Moment (kNm) 333.80 14.10 913.72 0.15
Req. Max Neg. Moment (kNm) -133.76 149 6.93 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 6.93 -0.00 0.00
Req. Max Punching Shear (kN) 929.88 156 3.69
Provided Punching Shear (kN) 5349.51 3.69
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 68.2 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 61.8

A72
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 13/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 6
Length (m): 41.33
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 2.70 S/S 7-#6
3 2.70/ 6.95 S/S 7-#6
4 6.95/12.15 S/S 7-#6
5 12.15/17.35 S/S 7-#6
6 17.35/25.16 S/S 7-#6
7 25.16/32.96 S/S 7-#6
8 32.96/38.21 S/S 7-#6
9 38.21/41.33 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.65 H/S 7-#6
2 1.65/ 3.30 S/S 7-#6
3 3.30/ 9.75 S/S 7-#6
4 9.75/14.95 S/S 7-#6
5 14.95/21.06 S/S 7-#6
6 21.06/29.26 S/S 7-#6
7 29.26/35.56 S/S 7-#6
8 35.56/41.33 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 0.95 None 3-#6
3 0.95/ 4.38 A73
None 10-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 14/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
4 4.38/ 9.58 None 15-#6
5 9.58/14.75 None 15-#6
6 14.75/19.96 None 15-#6
7 19.96/24.91 None 15-#6
8 24.91/30.36 None 16-#6
9 30.36/35.56 None 15-#6
10 35.56/41.16 None 16-#6
11 41.16/41.33 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 39.18) to (3.43, 39.65) 0.69 475.01x250.01 Wall 0.00
(3.43, 39.73) to (3.43, 43.10) 2.69 3375.00x250.01 Wall 0.00
(3.43, 43.10) to (3.43, 48.30) 6.98 5199.99x250.01 Wall 0.00
(3.43, 48.30) to (3.43, 53.50) 12.18 5199.99x250.01 Wall 0.00
(3.43, 53.50) to (3.43, 58.70) 17.38 5199.99x250.01 Wall 0.00
(3.43, 58.70) to (3.43, 63.65) 22.45 4950.00x250.01 Wall 0.00
(3.43, 63.65) to (3.43, 69.10) 27.65 5450.00x250.01 Wall 0.00
(3.43, 69.10) to (3.43, 74.30) 32.98 5199.99x250.01 Wall 0.00
(3.43, 74.30) to (3.43, 79.60) 38.23 5299.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 19.16 132 41.29
Provided Shear (kN) 0.00 41.29
Req. Max Pos. Moment (kNm) 192.99 177 4.38 232.08 1 24.91
Provided Pos. Moment (kNm) 333.80 4.38 731.04 24.91
Req. Max Neg. Moment (kNm) -150.31 309 9.58 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 9.58 -0.00 0.00
Req. Max Punching Shear (kN) 964.04 132 38.23
Provided Punching Shear (kN) 4663.97 38.23
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 69.8 Ld Co # 513
Max Average Unfactored Soil Bearing (kN/m2) 67.3

A74
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 15/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 9
Length (m): 13.30
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 4.90 H/S 7-#6
2 4.90/ 8.40 S/S 7-#6
3 8.40/13.30 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.90 H/S 7-#6
2 4.90/ 8.40 S/S 7-#6
3 8.40/13.30 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/13.15 38-#6 38-#6
3 13.15/13.30 1-#6 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 79.60) to (15.83, 79.60) 6.65 12400.00x250.01 Wall 0.00

A75
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 16/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.80 299 13.26
Provided Shear (kN) 0.00 13.26
Req. Max Pos. Moment (kNm) 14.26 299 12.85 296.22 1 0.15
Provided Pos. Moment (kNm) 333.80 12.85 1736.35 0.15
Req. Max Neg. Moment (kNm) -3.08 140 12.85 -85.46 126 0.15
Provided Neg. Moment (kNm) -354.70 12.85 -1849.79 0.15
Req. Max Punching Shear (kN) 1606.64 138 6.65
Provided Punching Shear (kN) 8849.19 6.65
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 54.3 Ld Co # 502
Max Average Unfactored Soil Bearing (kN/m2) 52.7

A76
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 17/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 12
Length (m): 40.78
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.15 H/S 7-#6
2 2.15/ 6.40 S/S 7-#6
3 6.40/11.60 S/S 7-#6
4 11.60/16.80 S/S 7-#6
5 16.80/24.61 S/S 7-#6
6 24.61/32.41 S/S 7-#6
7 32.41/37.66 S/S 7-#6
8 37.66/40.78 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.20 H/S 7-#6
2 4.20/ 9.00 S/S 7-#6
3 9.00/14.20 S/S 7-#6
4 14.20/20.51 S/S 7-#6
5 20.51/28.71 S/S 7-#6
6 28.71/35.01 S/S 7-#6
7 35.01/40.78 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 3.83 None 11-#6
3 3.83/ 9.03 None 15-#6
4 9.03/14.23 None 15-#6
5 14.23/19.40 A77
None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 18/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 19.40/24.36 None 15-#6
7 24.36/29.81 None 16-#6
8 29.81/35.01 None 15-#6
9 35.01/40.61 None 16-#6
10 40.61/40.78 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(15.83, 39.73) to (15.83, 43.10) 2.14 3375.00x250.01 Wall 0.00
(15.83, 43.10) to (15.83, 48.30) 6.43 5199.99x250.01 Wall 0.00
(15.83, 48.30) to (15.83, 53.50) 11.63 5199.99x250.01 Wall 0.00
(15.83, 53.50) to (15.83, 58.70) 16.83 5199.99x250.01 Wall 0.00
(15.83, 58.70) to (15.83, 63.65) 21.90 4950.00x250.01 Wall 0.00
(15.83, 63.65) to (15.83, 69.10) 27.10 5450.00x250.01 Wall 0.00
(15.83, 69.10) to (15.83, 74.30) 32.43 5199.99x250.01 Wall 0.00
(15.83, 74.30) to (15.83, 79.60) 37.68 5299.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 19.65 138 40.74
Provided Shear (kN) 0.00 40.74
Req. Max Pos. Moment (kNm) 131.89 182 35.03 231.84 1 24.36
Provided Pos. Moment (kNm) 333.80 35.03 731.04 24.36
Req. Max Neg. Moment (kNm) -163.76 155 14.23 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 14.23 -0.00 0.00
Req. Max Punching Shear (kN) 987.01 138 37.68
Provided Punching Shear (kN) 4663.97 37.68
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 69.3 Ld Co # 519
Max Average Unfactored Soil Bearing (kN/m2) 67.4

A78
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 19/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 10
Length (m): 6.08
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.05 H/S 7-#6
2 3.05/ 6.08 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 2.25 H/S 7-#6
2 2.25/ 3.85 S/S 7-#6
3 3.85/ 6.08 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 5.90 None 17-#6
3 5.90/ 6.08 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(4.42, 34.00) to (4.42, 39.18) 3.04 5175.00x250.01 Wall 0.00
CONCRETE CAPACITY
A79
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 20/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 20.38 160 6.04
Provided Shear (kN) 0.00 6.04
Req. Max Pos. Moment (kNm) 16.10 159 0.45 217.86 1 0.15
Provided Pos. Moment (kNm) 333.80 0.45 776.64 0.15
Req. Max Neg. Moment (kNm) -0.00 10 0.00 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 0.00 -0.00 0.00
Req. Max Punching Shear (kN) 880.73 1 3.04
Provided Punching Shear (kN) 4591.42 3.04
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 68.2 Ld Co # 523
Max Average Unfactored Soil Bearing (kN/m2) 66.3

A80
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 21/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 5
Length (m): 1.90
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 420.62
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 395.22
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 439.67 Bottom Bar Depth (mm) 414.27
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/ 1.75 5-#6 5-#6
3 1.75/ 1.90 None 1-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.05 Not Applic. None
2 1.85/ 1.90 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

A81
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 22/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 34.00) to (4.42, 34.00) 0.95 1000.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 26.32 138 1.85
Provided Shear (kN) 640.67 1.85
Req. Max Pos. Moment (kNm) 20.34 138 1.45 45.47 1 0.15
Provided Pos. Moment (kNm) 338.12 1.45 239.40 0.15
Req. Max Neg. Moment (kNm) -0.70 306 0.25 -7.89 298 0.15
Provided Neg. Moment (kNm) -339.03 0.25 -254.33 0.15
Req. Max Punching Shear (kN) 224.11 138 0.95
Provided Punching Shear (kN) 2373.59 0.95
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 81.8 Ld Co # 502
Max Average Unfactored Soil Bearing (kN/m2) 61.8

A82
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 23/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 3
Length (m): 34.78
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.45 H/S 7-#6
2 2.45/ 7.00 S/S 7-#6
3 7.00/12.20 S/S 7-#6
4 12.20/17.40 S/S 7-#6
5 17.40/22.61 S/S 7-#6
6 22.61/27.81 S/S 7-#6
7 27.81/32.36 S/S 7-#6
8 32.36/34.78 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.20 H/S 7-#6
2 4.20/10.05 S/S 7-#6
3 10.05/15.00 S/S 7-#6
4 15.00/19.86 S/S 7-#6
5 19.86/25.01 S/S 7-#6
6 25.01/30.21 S/S 7-#6
7 30.21/34.78 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 4.43 None 13-#6
3 4.43/ 9.63 None 15-#6
4 9.63/14.80 None 15-#6
5 14.80/20.01 A83
None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 24/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.01/25.21 None 15-#6
7 25.21/30.41 None 15-#6
8 30.41/34.61 None 12-#6
9 34.61/34.78 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 0.13) to (3.43, 4.10) 2.44 3975.00x250.01 Wall 0.00
(3.43, 4.10) to (3.43, 9.30) 7.03 5199.99x250.01 Wall 0.00
(3.43, 9.30) to (3.43, 14.50) 12.23 5199.99x250.01 Wall 0.00
(3.43, 14.50) to (3.43, 19.70) 17.43 5199.99x250.01 Wall 0.00
(3.43, 19.70) to (3.43, 24.90) 22.63 5199.99x250.01 Wall 0.00
(3.43, 24.90) to (3.43, 30.10) 27.83 5199.99x250.01 Wall 0.00
(3.43, 30.10) to (3.43, 34.00) 32.38 3899.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 20.69 167 34.74
Provided Shear (kN) 0.00 34.74
Req. Max Pos. Moment (kNm) 101.59 138 4.43 259.95 1 25.21
Provided Pos. Moment (kNm) 333.80 4.43 685.55 25.21
Req. Max Neg. Moment (kNm) -165.86 182 14.83 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 14.83 -0.00 0.00
Req. Max Punching Shear (kN) 1052.53 1 22.63
Provided Punching Shear (kN) 4605.92 22.63
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 82.7 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 72.3

A84
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 25/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 4
Length (m): 13.30
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 4.90 H/S 7-#6
2 4.90/ 8.40 S/S 7-#6
3 8.40/13.30 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.90 H/S 7-#6
2 4.90/ 8.40 S/S 7-#6
3 8.40/13.30 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/13.15 38-#6 38-#6
3 13.15/13.30 1-#6 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 0.13) to (15.83, 0.13) 6.65 12400.00x250.01 Wall 0.00

A85
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 26/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 14.48 155 13.26
Provided Shear (kN) 0.00 13.26
Req. Max Pos. Moment (kNm) 12.52 155 12.85 292.54 1 0.15
Provided Pos. Moment (kNm) 333.80 12.85 1736.35 0.15
Req. Max Neg. Moment (kNm) -3.08 133 12.85 -85.46 126 0.15
Provided Neg. Moment (kNm) -354.70 12.85 -1849.79 0.15
Req. Max Punching Shear (kN) 1527.64 155 6.65
Provided Punching Shear (kN) 8849.19 6.65
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 52.7 Ld Co # 519
Max Average Unfactored Soil Bearing (kN/m2) 49.6

A86
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 27/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 11
Length (m): 35.23
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.45 H/S 7-#6
2 2.45/ 7.00 S/S 7-#6
3 7.00/12.20 S/S 7-#6
4 12.20/17.40 S/S 7-#6
5 17.40/22.61 S/S 7-#6
6 22.61/27.81 S/S 7-#6
7 27.81/32.61 S/S 7-#6
8 32.61/35.23 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.20 H/S 7-#6
2 4.20/10.05 S/S 7-#6
3 10.05/15.25 S/S 7-#6
4 15.25/19.86 S/S 7-#6
5 19.86/24.81 S/S 7-#6
6 24.81/30.21 S/S 7-#6
7 30.21/35.23 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 4.43 None 13-#6
3 4.43/ 9.63 None 15-#6
4 9.63/14.80 None 15-#6
5 14.80/20.01 A87
None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 28/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.01/25.21 None 15-#6
7 25.21/30.41 None 15-#6
8 30.41/35.06 None 14-#6
9 35.06/35.23 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(15.83, 0.13) to (15.83, 4.10) 2.44 3975.00x250.01 Wall 0.00
(15.83, 4.10) to (15.83, 9.30) 7.03 5199.99x250.01 Wall 0.00
(15.83, 9.30) to (15.83, 14.50) 12.23 5199.99x250.01 Wall 0.00
(15.83, 14.50) to (15.83, 19.70) 17.43 5199.99x250.01 Wall 0.00
(15.83, 19.70) to (15.83, 24.90) 22.63 5199.99x250.01 Wall 0.00
(15.83, 24.90) to (15.83, 30.10) 27.83 5199.99x250.01 Wall 0.00
(15.83, 30.10) to (15.83, 34.45) 32.60 4350.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 26.24 136 35.19
Provided Shear (kN) 0.00 35.19
Req. Max Pos. Moment (kNm) 125.99 132 4.43 275.93 1 25.21
Provided Pos. Moment (kNm) 333.80 4.43 685.55 25.21
Req. Max Neg. Moment (kNm) -176.06 155 14.83 -0.00 -1 0.00
Provided Neg. Moment (kNm) -354.70 14.83 -0.00 0.00
Req. Max Punching Shear (kN) 1111.89 136 32.60
Provided Punching Shear (kN) 4115.25 32.60
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 90.3 Ld Co # 500
Max Average Unfactored Soil Bearing (kN/m2) 75.7

A88
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 29/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 8
Length (m): 35.55
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.52º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 7.25 H/S 7-#6
2 7.25/24.06 S/S 14-#6
3 24.06/35.55 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/15.25 H/S 7-#6
2 15.25/35.55 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.70 3-#6 3-#6
2 0.70/ 1.15 2-#6 2-#6
3 1.15/ 2.10 3-#6 3-#6
4 2.10/13.58 33-#6 33-#6
5 13.58/20.11 None 19-#6
6 20.11/23.66 None 11-#6
7 23.66/27.26 None 11-#6
8 27.26/30.86 None 11-#6
9 30.86/34.76 None 12-#6
10 34.76/35.55 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
A89
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 30/30
DataBase: Brigade Headquarters Date: 05/15/19 12:17:24
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.56 Not Applic. None
2 34.87/35.55 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(3.43, 39.18) to (3.43, 39.65) 1.10 475.01x250.01 Wall -89.48
(3.43, 39.18) to (4.42, 39.18) 1.60 1000.00x250.01 Wall 0.52
(3.43, 39.73) to (15.83, 39.73) 7.30 12400.00x150.01 Wall 0.52
(4.42, 39.18) to (15.83, 39.18) 7.80 11400.00x150.01 Wall 0.52
(15.95, 39.48) to (22.43, 39.48) 16.86 6474.99x250.01 Wall 0.52
(22.43, 39.48) to (26.00, 39.48) 21.89 3575.00x150.01 Wall 0.52
(26.00, 39.48) to (29.60, 39.48) 25.48 3599.99x150.01 Wall 0.52
(29.60, 39.48) to (33.20, 39.48) 29.08 3599.99x150.01 Wall 0.52
(33.20, 39.48) to (36.77, 39.48) 32.66 3575.00x150.01 Wall 0.52
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 167.99 167 0.56
Provided Shear (kN) 671.55 0.56
Req. Max Pos. Moment (kNm) 189.56 306 13.50 467.49 1 2.10
Provided Pos. Moment (kNm) 335.06 13.50 1508.29 2.10
Req. Max Neg. Moment (kNm) -674.89 174 13.50 -83.37 126 2.10
Provided Neg. Moment (kNm) -700.42 13.50 -1606.80 2.10
Req. Max Punching Shear (kN) 1821.96 131 7.80
Provided Punching Shear (kN) 8064.94 7.80
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 82.3 Ld Co # 495
Max Average Unfactored Soil Bearing (kN/m2) 69.2

A90
A91
A92
FOR CMU WALL DESIGN
SEE FIRE PUMP HOUSE (BUILDING E)

A93
A94
SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
B. Battallion Headquarters

Building Design PAGE NO.

RAM Calculation Check……………………………………………………………………………………… B1 - B2

RAM Modeler………………………………….……..………………………………………………………… B3 - B3

RAM Frame Analysis - Loads and Applied Forces………………………………………………….…..… B 4 - B 22

RAM Concrete Pedestal Design……………………………………….………..…………………………… B 23 - B 26

RAM Concrete Analysis - Wall Forces……………………………………….………..…………………… B 27 - B 33

RAM Concrete Stem Wall……………………………………...…………..………………………………… B 34 - B 54

RAM Foundation - Spread Footing Design………………..……………..………………………………… B 55 - B 55

RAM Foundation - Continuous Footing Design………………..……………..…………………………… B 56 - B 78

Slab on Grade Design…………………………………………….…..……..…….…………………………… B 79 - B 80

CMU Wall Design…………………………………………….…..……..…….………………………………… B 81 - B 82


B1
B2
RAM Structural System V16.00.00.28. - Floor Plan: STEM
DataBase: Battalion Headquarters 05/07/19 09:39:57

2
2'

2.5
3
4
4.5

5'
5

A' B C D E F G H JK L M N P Q R S T'
T

B3
Loads and Applied Forces
RAM Frame 16.00.00.28
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

LOAD CASE: wind


ASCE 7-16
Exposure: C
Basic Wind Speed (km/h): 185.0
Apply Directionality Factor, Kd = 0.85
Use Topography Factor, Kzt: 1.00
Ground Elevation Factor, Ke: 1.00
Use Calculated Frequency for X-Dir.
Use Calculated Frequency for Y-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for X-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for Y-Dir.
Damping Ratio for Flexible Structures= 0.01
Mean Roof Height (m): Top Story Height + Parapet = 5.60
Ground Level: STEM
WIND PRESSURES:
X-Direction: Natural Frequency = 10.419 Structure is Rigid
Y-Direction: Natural Frequency = 7.048 Structure is Rigid
CpWindward = 0.80 qLeeward (qh) = 1.22 kN/m2
GCpn (Parapet): Windward = 1.50 Leeward = -1.00
Height Kz Kzt qz Gust Factor G CpLeeward Pressure (kN/m2)
m kN/m2 X Y X Y X Y
5.60 0.886 1.000 1.220 ---- ---- ---- ---- 3.049 3.049
4.00 0.849 1.000 1.169 0.850 0.850 -0.200 -0.500 1.002 1.313
5.60 0.886 1.000 1.220 ---- ---- ---- ---- 3.049 3.049
4.00 0.849 1.000 1.169 0.850 0.850 -0.200 -0.500 1.002 1.313
0.00 0.849 1.000 1.169 0.850 0.850 -0.200 -0.500 1.002 1.313

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_X
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 110.47 0.00 19.80 8.02
ROOF 2 4.00 86.73 0.00 59.63 6.30

APPLIED STORY FORCES


Type: Wind_ASCE716_1_X
Level Ht Fx Fy
m kN kN
ROOF 4.00 197.20 0.00
_________ _________
197.20 0.00

B4
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 2/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 297.24 19.80 8.02
ROOF 2 4.00 0.00 299.78 59.63 6.30

APPLIED STORY FORCES


Type: Wind_ASCE716_1_Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 597.02
_________ _________
0.00 597.02

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 82.85 0.00 19.80 10.43
ROOF 2 4.00 65.04 0.00 59.63 8.19

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X+E
Level Ht Fx Fy
m kN kN
ROOF 4.00 147.90 0.00
_________ _________
147.90 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X-E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 82.85 0.00 19.80 5.62
ROOF 2 4.00 65.04 0.00 59.63 4.41

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X-E
Level Ht Fx Fy
m kN kN
ROOF 4.00 147.90 B5 0.00
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 3/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
_________ _________
147.90 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 222.93 25.74 8.02
ROOF 2 4.00 0.00 224.83 65.62 6.30

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y+E
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 447.77
_________ _________
0.00 447.77

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y-E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 222.93 13.86 8.02
ROOF 2 4.00 0.00 224.83 53.64 6.30

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y-E
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 447.77
_________ _________
0.00 447.77

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X+Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 82.85 222.93 19.80 8.02
ROOF 2 4.00 65.04 224.83 59.63 6.30

B6
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 4/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X+Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 147.90 447.77
_________ _________
147.90 447.77

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X-Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 82.85 -222.93 19.80 8.02
ROOF 2 4.00 65.04 -224.83 59.63 6.30

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X-Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 147.90 -447.77
_________ _________
147.90 -447.77

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 62.14 167.20 13.86 10.43
ROOF 2 4.00 48.78 168.63 53.64 8.19

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Ht Fx Fy
m kN kN
ROOF 4.00 110.92 335.83
_________ _________
110.92 335.83

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Diaph.# Ht B7 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 5/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
m kN kN m m
ROOF 1 4.00 62.14 167.20 25.74 5.62
ROOF 2 4.00 48.78 168.63 65.62 4.41

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 4.00 110.92 335.83
_________ _________
110.92 335.83

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 62.14 -167.20 25.74 10.43
ROOF 2 4.00 48.78 -168.63 65.62 8.19

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CW
Level Ht Fx Fy
m kN kN
ROOF 4.00 110.92 -335.83
_________ _________
110.92 -335.83

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 62.14 -167.20 13.86 5.62
ROOF 2 4.00 48.78 -168.63 53.64 4.41

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 4.00 110.92 -335.83
_________ _________
110.92 -335.83
B8
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 6/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

LOAD CASE: seis


Seismic ASCE 7-16 Equivalent Lateral Force
Site Class: D Importance Factor: 1.50 Ss: 0.370 g S1: 0.170 g TL: 12.00 s
Fa: 1.504 Fv: 2.260 SDs: 0.371 g SD1: 0.256 g
Seismic Design Category: D
Provisions for: Force
Ground Level: STEM

Dir Eccent R Ta Equation Building Period-T


X + And - 4.0 User Defined Use Ta
Y + And - 4.0 User Defined Use Ta

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
X 0.177 1.444 0.177 0.177 0.139 0.543 0.024 0.139 1.000

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
Y 0.177 1.444 0.177 0.177 0.139 0.543 0.024 0.139 1.000

Total Building Weight (kN) = 16613.91

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 0.00 24.85 7.69
ROOF 2 4.00 942.11 0.00 59.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 0.00
_________ _________
2311.33 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 0.00 24.85 6.08
ROOF 2 4.00 B9 942.11 0.00 59.57 5.67
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 7/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 0.00
_________ _________
2311.33 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 1369.21 26.83 6.89
ROOF 2 4.00 0.00 942.11 61.57 6.30

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 2311.33
_________ _________
0.00 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 1369.21 22.87 6.89
ROOF 2 4.00 0.00 942.11 57.58 6.30

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 2311.33
_________ _________
0.00 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Diaph.# Ht B10 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 8/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
m kN kN m m
ROOF 1 4.00 1369.21 410.76 26.83 7.69
ROOF 2 4.00 942.11 282.63 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 693.40
_________ _________
2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 -410.76 26.83 7.69
ROOF 2 4.00 942.11 -282.63 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 -693.40
_________ _________
2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 410.76 26.83 7.69
ROOF 2 4.00 -942.11 282.63 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 693.40
_________ _________
-2311.33 693.40
B11
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 9/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 -410.76 26.83 7.69
ROOF 2 4.00 -942.11 -282.63 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 -693.40
_________ _________
-2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 1369.21 26.83 7.69
ROOF 2 4.00 282.63 942.11 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 2311.33
_________ _________
693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 -1369.21 26.83 7.69
ROOF 2 4.00 282.63 -942.11 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 B12 -2311.33
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 10/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
_________ _________
693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 1369.21 26.83 7.69
ROOF 2 4.00 -282.63 942.11 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 2311.33
_________ _________
-693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 -1369.21 26.83 7.69
ROOF 2 4.00 -282.63 -942.11 61.57 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 -2311.33
_________ _________
-693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 410.76 22.87 7.69
ROOF 2 4.00 942.11 282.63 57.58 6.93

B13
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 11/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 693.40
_________ _________
2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 -410.76 22.87 7.69
ROOF 2 4.00 942.11 -282.63 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 -693.40
_________ _________
2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 410.76 22.87 7.69
ROOF 2 4.00 -942.11 282.63 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 693.40
_________ _________
-2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
Level Diaph.# Ht B14 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 12/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
m kN kN m m
ROOF 1 4.00 -1369.21 -410.76 22.87 7.69
ROOF 2 4.00 -942.11 -282.63 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 -693.40
_________ _________
-2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 1369.21 22.87 7.69
ROOF 2 4.00 282.63 942.11 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 2311.33
_________ _________
693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 -1369.21 22.87 7.69
ROOF 2 4.00 282.63 -942.11 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 -2311.33
_________ _________
693.40 -2311.33
B15
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 13/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 1369.21 22.87 7.69
ROOF 2 4.00 -282.63 942.11 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 2311.33
_________ _________
-693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 -1369.21 22.87 7.69
ROOF 2 4.00 -282.63 -942.11 57.58 6.93

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 -2311.33
_________ _________
-693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 410.76 26.83 6.08
ROOF 2 4.00 942.11 282.63 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 B16 693.40
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 14/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
_________ _________
2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 -410.76 26.83 6.08
ROOF 2 4.00 942.11 -282.63 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 -693.40
_________ _________
2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 410.76 26.83 6.08
ROOF 2 4.00 -942.11 282.63 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 693.40
_________ _________
-2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 -410.76 26.83 6.08
ROOF 2 4.00 -942.11 -282.63 61.57 5.67

B17
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 15/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 -693.40
_________ _________
-2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 1369.21 26.83 6.08
ROOF 2 4.00 282.63 942.11 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 2311.33
_________ _________
693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 -1369.21 26.83 6.08
ROOF 2 4.00 282.63 -942.11 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 -2311.33
_________ _________
693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Diaph.# Ht B18 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 16/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
m kN kN m m
ROOF 1 4.00 -410.76 1369.21 26.83 6.08
ROOF 2 4.00 -282.63 942.11 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 2311.33
_________ _________
-693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 -1369.21 26.83 6.08
ROOF 2 4.00 -282.63 -942.11 61.57 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 -2311.33
_________ _________
-693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 410.76 22.87 6.08
ROOF 2 4.00 942.11 282.63 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 693.40
_________ _________
2311.33 693.40
B19
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 17/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1369.21 -410.76 22.87 6.08
ROOF 2 4.00 942.11 -282.63 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2311.33 -693.40
_________ _________
2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 410.76 22.87 6.08
ROOF 2 4.00 -942.11 282.63 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 693.40
_________ _________
-2311.33 693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1369.21 -410.76 22.87 6.08
ROOF 2 4.00 -942.11 -282.63 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2311.33 B20 -693.40
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 18/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21
_________ _________
-2311.33 -693.40

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 1369.21 22.87 6.08
ROOF 2 4.00 282.63 942.11 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 2311.33
_________ _________
693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 410.76 -1369.21 22.87 6.08
ROOF 2 4.00 282.63 -942.11 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 693.40 -2311.33
_________ _________
693.40 -2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 1369.21 22.87 6.08
ROOF 2 4.00 -282.63 942.11 57.58 5.67

B21
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 19/19
RSLF - Artillery Brigade
DataBase: Battalion Headquarters 05/07/19 09:47:21

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 2311.33
_________ _________
-693.40 2311.33

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -410.76 -1369.21 22.87 6.08
ROOF 2 4.00 -282.63 -942.11 57.58 5.67

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -693.40 -2311.33
_________ _________
-693.40 -2311.33

B22
Concrete Column Design
RAM Concrete Column v16.00.00.28
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/08/19 10:36:49
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 1 Grid Location: (H-1)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.70
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 395.47
Moment Top Major(kNm) -29.39
Minor(kNm) -43.35
Moment Bottom Major(kNm) 14.68
Minor(kNm) 21.48
Calculated Parameters (Angle = 55.87 degrees): Ld/Cap = 0.42
0.65 Pn(kN): 395.47
0.65 Mn Major(kNm): 70.81 0.65 Mn Minor(kNm): 104.46
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 395.47 395.47
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28

B23
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 2/4
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/08/19 10:36:49
Building Code: IBC Concrete Code: ACI 318-14

TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (2) 1.200 D + 1.600 Rfp
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 2 82.31 145.21 162.06 0.75 230.45 0.36
1 Minor: 2 82.31 145.21 162.06 0.75 230.45 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 179.94 82.31 179.94 82.31
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

B24
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 3/4
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/08/19 10:36:49
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 2 Grid Location: (J-1)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.70
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 395.47
Moment Top Major(kNm) -29.39
Minor(kNm) 43.48
Moment Bottom Major(kNm) 14.69
Minor(kNm) -21.52
Calculated Parameters (Angle = 55.94 degrees): Ld/Cap = 0.42
0.65 Pn(kN): 395.47
0.65 Mn Major(kNm): 70.67 0.65 Mn Minor(kNm): 104.55
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 395.47 395.47
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28

B25
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 4/4
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/08/19 10:36:49
Building Code: IBC Concrete Code: ACI 318-14

TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (2) 1.200 D + 1.600 Rfp
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 2 82.31 145.21 162.06 0.75 230.45 0.36
1 Minor: 2 82.31 145.21 162.06 0.75 230.45 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 179.94 82.31 179.94 82.31
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

B26
Wall Forces
RAM Concrete Analysis v16.00.00.28
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14

Story: ROOF
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 137.59 -32.89 17.18 -0.11 0.81
Roof Live Load 7.32 -3.59 2.63 -0.01 0.08

2 Dead Load 312.18 29.30 -52.70 -0.01 -0.06


Roof Live Load 26.62 3.63 -5.43 -0.00 0.01

3 Dead Load 39.42 0.45 4.20 0.00 0.02


Roof Live Load 0.62 0.05 0.50 0.00 0.00

4 Dead Load 46.49 0.44 1.66 0.00 0.02


Roof Live Load 0.42 0.03 0.10 0.00 0.00

5 Dead Load 39.67 0.24 -1.61 0.00 0.02


Roof Live Load 0.63 -0.01 -0.34 0.00 0.00

6 Dead Load 141.64 36.97 -12.20 -0.11 0.80


Roof Live Load 7.57 3.85 -2.32 -0.01 0.08

7 Dead Load 316.38 25.52 -53.78 0.01 0.08


Roof Live Load 26.88 3.39 -5.49 0.00 -0.01

8 Dead Load 496.05 5.69 -7.45 -0.00 -0.01


Roof Live Load 44.72 0.63 -0.96 -0.00 -0.00

9 Dead Load 496.35 4.55 -10.36 0.00 0.01


Roof Live Load 44.74 0.56 -1.13 0.00 0.00

10 Dead Load 501.31 1.26 0.30 -0.00 -0.00


Roof Live Load 45.42 0.19 -0.32 -0.00 -0.00

11 Dead Load 501.31 0.45 -2.89 0.00 0.00


Roof Live Load 45.42 0.14 -0.51 0.00 0.00

12 Dead Load 533.89 34.05 -16.32 -0.00 -0.00


Roof Live Load 52.11 6.86 -3.75 -0.00 -0.00

13 Dead Load 533.86 33.22 -19.53 0.00 0.00


Roof Live Load 52.11 6.81 -3.94 0.00 0.00

14 Dead Load 654.40 33.38 -14.48 -0.00 -0.00


Roof Live Load 76.72 6.69 -3.38 -0.00 -0.00

15 Dead Load 654.24 B27 32.44 -18.05 0.00 0.00


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 2/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 76.71 6.63 -3.60 0.00 0.00

16 Dead Load 655.29 -31.00 23.69 -0.00 -0.05


Roof Live Load 76.85 -6.48 3.96 -0.00 -0.00

17 Dead Load 660.74 -25.40 12.67 0.00 0.01


Roof Live Load 77.18 -6.14 3.28 0.00 0.00

18 Dead Load 398.41 -9.01 52.23 0.02 -0.57


Roof Live Load 40.06 -2.30 6.72 0.00 -0.05

19 Dead Load 443.13 -2.99 30.80 0.02 0.39


Roof Live Load 42.75 -2.00 5.42 0.00 0.04

20 Dead Load 97.57 -0.45 1.41 0.05 -0.23


Roof Live Load 9.16 -0.11 0.10 0.01 -0.03

21 Dead Load 398.51 -87.67 41.78 -0.04 0.55


Roof Live Load 34.70 -10.18 4.77 -0.00 0.06

22 Dead Load 115.16 -4.25 -10.48 0.05 -0.35


Roof Live Load 10.18 -0.19 -0.70 0.01 -0.04

23 Dead Load 478.18 -88.58 32.14 0.11 -0.96


Roof Live Load 39.09 -10.23 4.16 0.01 -0.09

24 Dead Load 46.51 0.09 -3.06 0.07 -0.54


Roof Live Load 3.09 0.09 -0.08 0.01 -0.05

25 Dead Load 106.67 -11.21 15.33 0.09 -0.89


Roof Live Load 5.56 -1.30 1.91 0.01 -0.08

26 Dead Load 46.58 0.94 6.99 -0.00 -0.07


Roof Live Load 1.03 0.07 0.70 -0.00 -0.01

27 Dead Load 56.03 1.21 2.17 -0.00 -0.04


Roof Live Load 0.88 0.07 0.14 -0.00 -0.00

28 Dead Load 53.94 0.49 -6.23 -0.00 -0.04


Roof Live Load 1.47 0.02 -0.64 -0.00 -0.01

29 Dead Load 151.32 19.65 -24.92 0.09 -0.88


Roof Live Load 8.21 1.80 -2.48 0.01 -0.08

30 Dead Load 72.50 B28 -0.24 0.86 0.07 -0.53


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 3/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 4.64 -0.10 -0.06 0.01 -0.05

31 Dead Load 152.06 -38.33 16.12 -0.13 1.05


Roof Live Load 7.97 -3.99 2.65 -0.01 0.10

32 Dead Load 253.57 16.33 -51.28 -0.01 -0.09


Roof Live Load 21.30 2.19 -5.18 -0.00 0.01

33 Dead Load 42.95 0.12 3.17 0.00 0.03


Roof Live Load 0.67 0.03 0.44 0.00 0.00

34 Dead Load 50.47 -0.00 0.00 0.00 0.02


Roof Live Load 0.45 -0.00 0.00 0.00 0.00

35 Dead Load 42.95 -0.12 -3.17 0.00 0.03


Roof Live Load 0.67 -0.03 -0.44 0.00 0.00

36 Dead Load 152.06 38.33 -16.12 -0.13 1.05


Roof Live Load 7.97 3.99 -2.65 -0.01 0.10

37 Dead Load 253.57 16.33 -51.28 0.01 0.09


Roof Live Load 21.30 2.19 -5.18 0.00 -0.01

38 Dead Load 492.36 9.48 -13.89 -0.00 -0.01


Roof Live Load 44.31 1.10 -1.46 -0.00 -0.00

39 Dead Load 492.36 9.48 -13.89 0.00 0.01


Roof Live Load 44.31 1.10 -1.46 0.00 0.00

40 Dead Load 500.60 -0.26 -0.21 -0.00 -0.00


Roof Live Load 45.27 -0.02 -0.03 -0.00 -0.00

41 Dead Load 500.60 -0.26 -0.21 0.00 0.00


Roof Live Load 45.27 -0.02 -0.03 0.00 0.00

42 Dead Load 500.26 0.04 0.36 -0.00 -0.00


Roof Live Load 45.24 0.00 0.03 -0.00 -0.00

43 Dead Load 500.26 0.04 0.36 0.00 0.00


Roof Live Load 45.24 0.00 0.03 0.00 0.00

44 Dead Load 476.18 0.10 0.34 -0.00 -0.00


Roof Live Load 43.06 0.01 0.03 -0.00 -0.00

45 Dead Load 476.18 B29 0.10 0.34 0.00 0.00


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 4/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 43.06 0.01 0.03 0.00 0.00

46 Dead Load 524.49 0.34 0.50 -0.00 -0.00


Roof Live Load 47.43 0.03 0.05 -0.00 -0.00

47 Dead Load 524.49 0.34 0.50 0.00 0.00


Roof Live Load 47.43 0.03 0.05 0.00 0.00

48 Dead Load 499.38 -1.20 5.25 -0.00 -0.00


Roof Live Load 45.10 -0.17 0.56 -0.00 -0.00

49 Dead Load 499.38 -1.20 5.25 0.00 0.00


Roof Live Load 45.10 -0.17 0.56 0.00 0.00

50 Dead Load 427.16 -60.69 59.21 -0.01 -0.08


Roof Live Load 36.85 -7.39 6.03 -0.00 0.01

51 Dead Load 427.16 -60.69 59.21 0.01 0.08


Roof Live Load 36.85 -7.39 6.03 0.00 -0.01

52 Dead Load 140.07 -35.31 14.83 0.10 -0.78


Roof Live Load 7.46 -3.74 2.48 0.01 -0.07

53 Dead Load 39.57 0.11 2.92 -0.00 -0.02


Roof Live Load 0.62 0.03 0.42 -0.00 -0.00

54 Dead Load 46.51 -0.00 0.00 -0.00 -0.02


Roof Live Load 0.42 -0.00 0.00 -0.00 -0.00

55 Dead Load 39.57 -0.11 -2.92 -0.00 -0.02


Roof Live Load 0.62 -0.03 -0.42 -0.00 -0.00

56 Dead Load 140.07 35.31 -14.83 0.10 -0.78


Roof Live Load 7.46 3.74 -2.48 0.01 -0.07

Story: STEM
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 499.43 21.20 -0.34 -2.43 5.72
Roof Live Load 19.12 1.31 -0.02 -0.17 0.43

2 Dead Load 328.80 33.97 -14.51 0.96 -1.94


Roof Live Load 25.81 4.20 -1.39 0.06 -0.11

3 Dead Load 333.12 B30 31.01 -14.24 -0.99 1.99


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 5/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 26.07 4.02 -1.37 -0.06 0.11

4 Dead Load 522.26 11.53 -2.29 0.00 0.00


Roof Live Load 44.24 1.30 -0.23 0.00 0.00

5 Dead Load 522.72 10.97 -2.25 -0.00 -0.00


Roof Live Load 44.27 1.27 -0.22 -0.00 -0.00

6 Dead Load 532.65 2.37 -0.22 0.00 -0.00


Roof Live Load 45.58 0.49 -0.05 -0.00 -0.00

7 Dead Load 532.65 2.35 -0.22 -0.00 0.00


Roof Live Load 45.58 0.49 -0.05 0.00 0.00

8 Dead Load 568.80 36.64 -4.67 -0.00 0.00


Roof Live Load 52.99 7.49 -0.96 -0.00 0.00

9 Dead Load 568.75 36.61 -4.65 0.00 -0.00


Roof Live Load 52.99 7.49 -0.96 0.00 -0.00

10 Dead Load 679.85 34.56 -4.33 0.00 -0.00


Roof Live Load 75.68 7.04 -0.89 0.00 -0.00

11 Dead Load 679.83 34.75 -4.33 -0.00 0.00


Roof Live Load 75.67 7.05 -0.89 -0.00 0.00

12 Dead Load 679.38 -35.80 5.47 0.00 0.00


Roof Live Load 75.68 -7.10 1.00 0.00 0.00

13 Dead Load 687.73 -25.45 3.81 -0.00 0.00


Roof Live Load 76.19 -6.47 0.89 -0.00 -0.00

14 Dead Load 423.68 -14.84 13.81 1.38 -3.10


Roof Live Load 40.63 -3.16 1.69 0.13 -0.28

15 Dead Load 465.37 -7.85 12.86 -1.31 3.50


Roof Live Load 43.12 -2.80 1.64 -0.12 0.30

16 Dead Load 105.26 -0.44 0.65 0.14 -0.34


Roof Live Load 9.37 -0.07 0.10 0.02 -0.05

17 Dead Load 427.69 -83.59 5.63 -1.11 2.61


Roof Live Load 34.18 -10.53 0.76 -0.11 0.27

18 Dead Load 121.60 B31 -0.67 0.09 0.09 -0.44


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 6/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 10.31 0.00 -0.06 0.02 -0.06

19 Dead Load 512.89 -79.59 4.86 1.58 -3.15


Roof Live Load 38.95 -10.29 0.71 0.14 -0.30

20 Dead Load 61.94 -0.77 -5.75 0.79 -1.97


Roof Live Load 3.74 -0.02 -0.36 0.06 -0.15

21 Dead Load 436.76 160.18 -5.84 0.55 -1.41


Roof Live Load 17.49 9.48 -0.34 0.04 -0.10

22 Dead Load 86.62 1.19 7.21 1.01 -2.45


Roof Live Load 5.19 0.04 0.44 0.07 -0.17

23 Dead Load 478.41 -0.00 -0.00 -0.81 1.98


Roof Live Load 18.55 -0.00 -0.00 -0.06 0.14

24 Dead Load 281.76 8.73 -12.62 0.95 -2.30


Roof Live Load 21.52 1.89 -1.27 0.05 -0.12

25 Dead Load 281.76 8.73 -12.62 -0.95 2.30


Roof Live Load 21.52 1.89 -1.27 -0.05 0.12

26 Dead Load 517.65 16.69 -3.63 0.00 0.00


Roof Live Load 43.69 1.93 -0.38 0.00 0.00

27 Dead Load 517.65 16.69 -3.63 -0.00 -0.00


Roof Live Load 43.69 1.93 -0.38 -0.00 -0.00

28 Dead Load 530.92 0.19 -0.10 0.00 -0.00


Roof Live Load 45.24 0.03 -0.00 0.00 -0.00

29 Dead Load 530.92 0.19 -0.10 -0.00 0.00


Roof Live Load 45.24 0.03 -0.00 -0.00 0.00

30 Dead Load 530.87 -0.05 0.02 -0.00 0.00


Roof Live Load 45.24 -0.01 0.00 -0.00 0.00

31 Dead Load 530.87 -0.05 0.02 0.00 -0.00


Roof Live Load 45.24 -0.01 0.00 0.00 -0.00

32 Dead Load 505.32 0.02 -0.03 -0.00 0.00


Roof Live Load 43.06 0.00 -0.00 0.00 -0.00

33 Dead Load 505.32 B32 0.02 -0.03 0.00 -0.00


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 7/7
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 09:50:15
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 43.06 0.00 -0.00 -0.00 0.00

34 Dead Load 556.58 0.13 -0.10 -0.00 -0.00


Roof Live Load 47.43 0.01 -0.01 -0.00 0.00

35 Dead Load 556.58 0.13 -0.10 0.00 0.00


Roof Live Load 47.43 0.01 -0.01 0.00 -0.00

36 Dead Load 527.83 -4.85 0.92 -0.00 0.00


Roof Live Load 44.87 -0.57 0.09 -0.00 0.00

37 Dead Load 527.83 -4.85 0.92 0.00 -0.00


Roof Live Load 44.87 -0.57 0.09 0.00 -0.00

38 Dead Load 448.89 -67.51 15.46 0.98 -1.98


Roof Live Load 35.82 -8.21 1.49 0.06 -0.11

39 Dead Load 448.89 -67.51 15.46 -0.98 1.98


Roof Live Load 35.82 -8.21 1.49 -0.06 0.11

40 Dead Load 500.10 -0.00 -0.00 2.42 -5.72


Roof Live Load 19.10 -0.00 -0.00 0.17 -0.42

B33
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Section Cut ID: SC1H:233 (Horizontal)


Story: STEM
Ag = 236250 cm2 Imaj = 387874852357 Imin = 78711622385 cm4
cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:233I
SC1H:233JSC1H:233K
SC1H:233LSC1H:233M
SC1H:233N
SC1H:233O
SC1H:233P
SC1H:233Q
SC1H:233R

SC1H:233H

Min

SC1H:233T
SC1H:233A
SC1H:233BSC1H:233C
SC1H:233D
SC1H:233E
SC1H:233F
SC1H:233G
SC1H:233S
SC1H:233U
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.035 OK
Pu = 13079.97 kN phiPn = 376248.97 kN
Mu = 25885.9 kNm at Beta = 3.5 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:233A:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 148.8 kN phiVn = 2711.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:233B:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 114.9 kN phiVnB34
= 3547.4 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:233C:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 105.8 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:233D:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 127.3 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:233E:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 123.2 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:233F:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 142.3 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:233G:
Length = 3.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 164.0 kN phiVn = 2660.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:233H:
Length = 12.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 629.0 kN phiVn = 8425.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5
B35
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 3/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Segment SC1H:233I:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 154.9 kN phiVn = 2711.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:233J:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 124.0 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:233K:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 115.1 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:233L:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 136.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:233M:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 133.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:233N:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 128.0 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:233O:
Length = 3.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat:
B36#5@150 mm oc
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 4/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Vu = 144.0 kN phiVn = 2660.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:233P:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 40.5 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:233Q:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 154.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:233R:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 67.5 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:233S:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 30.0 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:233T:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 169.4 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:233U:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 67.5 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5 B37
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 5/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.072% (11.6.2) OK
Segment SC1H:233A:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233C:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233F:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233H:
Max Vert Bar Spacing Limit: 457 mm Actual: B38150 mm (11.7.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 6/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2)
B39 OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 7/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Segment SC1H:233P:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233R:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233S:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233T:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:233U:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

B40
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 8/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Section Cut ID: SC1H:234 (Horizontal)


Story: STEM
Ag = 229595 cm2 Imaj = 367122804510 Imin = 79712631936 cm4
cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:234Q
SC1H:234P
SC1H:234O
SC1H:234N
SC1H:234M
SC1H:234LSC1H:234KSC1H:234J

SC1H:234I

Min

SC1H:234H
SC1H:234G
SC1H:234FSC1H:234E
SC1H:234D
SC1H:234CSC1H:234BSC1H:234A
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.032 OK
Pu = 11612.98 kN phiPn = 364964.22 kN
Mu = 17379.1 kNm at Beta = -0.0 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:234A:
Length = 5.18 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 157.2 kN phiVn = 3530.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:234B:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 78.6 kN phiVnB41
= 3547.4 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 9/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:234C:
Length = 5.45 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 71.2 kN phiVn = 3718.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:234D:
Length = 4.95 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 64.5 kN phiVn = 3376.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:234E:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 67.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:234F:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 69.1 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:234G:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 94.3 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:234H:
Length = 3.37 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 115.7 kN phiVn = 2298.3 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5
B42
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 10/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Segment SC1H:234I:
Length = 12.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 507.0 kN phiVn = 8425.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:234J:
Length = 5.18 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 157.2 kN phiVn = 3530.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:234K:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 78.6 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:234L:
Length = 5.45 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 71.2 kN phiVn = 3718.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:234M:
Length = 4.95 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 64.5 kN phiVn = 3376.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:234N:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 67.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:234O:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat:
B43#5@150 mm oc
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 11/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Vu = 69.1 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:234P:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 94.3 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:234Q:
Length = 3.37 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 115.7 kN phiVn = 2298.3 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.060% (11.6.2) OK
Segment SC1H:234A:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234C:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234E: B44
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 12/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234F:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234H:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3)
B45 OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 13/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234P:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:234Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

B46
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 14/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Section Cut ID: SC1H:235 (Horizontal)


Story: STEM
Ag = 236250 cm2 Imaj = 387874852357 Imin = 78711622385 cm4
cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:235I
SC1H:235JSC1H:235K
SC1H:235LSC1H:235M
SC1H:235N
SC1H:235O
SC1H:235P
SC1H:235Q
SC1H:235R

SC1H:235H

Min

SC1H:235T
SC1H:235A
SC1H:235BSC1H:235C
SC1H:235D
SC1H:235E
SC1H:235F
SC1H:235G
SC1H:235S
SC1H:235U
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.035 OK
Pu = 13085.98 kN phiPn = 376248.97 kN
Mu = 26012.3 kNm at Beta = 3.5 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:235A:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 139.5 kN phiVn = 2711.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:235B:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 112.9 kN phiVnB47
= 3547.4 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 15/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:235C:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 105.1 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:235D:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 125.8 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:235E:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 122.3 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:235F:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 139.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:235G:
Length = 3.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 151.3 kN phiVn = 2660.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:235H:
Length = 12.35 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 629.0 kN phiVn = 8425.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E17 (LC 91)
Code Ref: 11.5.4.5
B48
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 16/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Segment SC1H:235I:
Length = 3.97 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 145.6 kN phiVn = 2711.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:235J:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 122.0 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:235K:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 114.5 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:235L:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 135.2 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:235M:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 132.6 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:235N:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 126.8 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:235O:
Length = 3.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat:
B49#5@150 mm oc
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 17/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Shear Results:
Vu = 129.7 kN phiVn = 2660.6 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:235P:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 40.5 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:235Q:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 154.7 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:235R:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 50.1 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:235S:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 30.0 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:235T:
Length = 5.20 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 169.4 kN phiVn = 3547.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:235U:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 51.5 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5 B50
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 18/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.072% (11.6.2) OK
Segment SC1H:235A:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235C:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235F:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235H:
Max Vert Bar Spacing Limit: 457 mm Actual: B51150 mm (11.7.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 19/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2)
B52 OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 20/296
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14
Segment SC1H:235P:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235R:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235S:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235T:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:235U:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

B53
Wall Panel Reinforcing
RAM Concrete Shearwall 16.00.00.28
RSLF - Artillery Brigade
Database: Battalion Headquarters 05/07/19 11:22:23
Design Code: ACI 318-14

Wall Design Group: 1


Bar Pattern Template: 250mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 221 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
222 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
223 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
224 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
225 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
226 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
227 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
228 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
229 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
230 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
231 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
232 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%

Wall Design Group: 2


Bar Pattern Template: 150mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 206 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%
207 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%

B54
Spread Footing Design Summary
RAM Foundation v16.00.00.28
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/07/19 12:07:40
Building Code: IBC Design Code: ACI318-14

Orientation Dimensions (m) f'c/fy Bottom Reinforcement Top Reinforcement


Grid Col/Foot Length Width Thick N/mm2 Parallel to Parallel to Parallel to Parallel to
Length Width Length Width
(H - 1) 90.00/90.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
(J - 1) 90.00/90.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
* - Number between () in reinforcement is quantity of bars in center strip of rectangular footing

B55
Continuous Foundation Design
RAM Foundation v16.00.00.28
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 2
Length (m): 14.55
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 5.40 H/S 7-#6
2 5.40/ 9.15 S/S 7-#6
3 9.15/14.55 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.40 H/S 7-#6
2 5.40/ 9.15 S/S 7-#6
3 9.15/14.55 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 3-#6 3-#6
2 0.80/13.75 37-#6 37-#6
3 13.75/14.55 3-#6 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 13.86/14.55 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS
B56
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 2/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.13, 0.13) to (0.13, 12.47) 7.27 12349.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 74.59 160 13.86
Provided Shear (kN) 671.55 13.86
Req. Max Pos. Moment (kNm) 67.43 160 13.45 239.88 1 0.80
Provided Pos. Moment (kNm) 335.06 13.45 1691.29 0.80
Req. Max Neg. Moment (kNm) -16.52 159 13.45 -63.85 296 0.80
Provided Neg. Moment (kNm) -355.95 13.45 -1801.74 0.80
Req. Max Punching Shear (kN) 1204.87 160 7.27
Provided Punching Shear (kN) 8819.51 7.27
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 43.5 Ld Co # 524
Max Average Unfactored Soil Bearing (kN/m2) 38.3

B57
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 3/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 13
Length (m): 14.55
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 7.25 H/S 7-#6
2 7.25/14.55 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.40 H/S 7-#6
2 5.40/ 9.15 S/S 7-#6
3 9.15/14.55 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 3-#6 3-#6
2 0.80/13.75 None 37-#6
3 13.75/14.55 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 13.86/14.55 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

B58
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 4/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(79.47, 0.13) to (79.47, 12.47) 7.27 12349.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 64.05 150 13.86
Provided Shear (kN) 671.55 13.86
Req. Max Pos. Moment (kNm) 57.86 150 13.45 240.37 1 0.80
Provided Pos. Moment (kNm) 335.06 13.45 1691.29 0.80
Req. Max Neg. Moment (kNm) -13.26 321 13.45 -5.02 296 0.00
Provided Neg. Moment (kNm) -355.95 13.45 -145.40 0.00
Req. Max Punching Shear (kN) 1069.30 150 7.27
Provided Punching Shear (kN) 8819.51 7.27
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 42.0 Ld Co # 514
Max Average Unfactored Soil Bearing (kN/m2) 36.1

B59
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 5/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 7
Length (m): 7.40
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.70 H/S 7-#6
2 3.70/ 7.40 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 2.75 H/S 7-#6
2 2.75/ 4.65 S/S 7-#6
3 4.65/ 7.40 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 6.60 None 17-#6
3 6.60/ 7.40 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 6.71/ 7.40 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

B60
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 6/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(34.00, 11.48) to (39.20, 11.48) 3.70 5199.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 101.21 177 6.71
Provided Shear (kN) 671.55 6.71
Req. Max Pos. Moment (kNm) 91.79 177 6.30 155.92 1 0.80
Provided Pos. Moment (kNm) 335.06 6.30 776.76 0.80
Req. Max Neg. Moment (kNm) -0.00 185 0.00 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 0.00 -0.00 0.00
Req. Max Punching Shear (kN) 770.04 1 3.70
Provided Punching Shear (kN) 4605.92 3.70
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 49.0 Ld Co # 514
Max Average Unfactored Soil Bearing (kN/m2) 48.2

B61
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 7/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 3
Length (m): 36.07
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.10 H/S 7-#6
2 3.10/ 7.65 S/S 7-#6
3 7.65/12.85 S/S 7-#6
4 12.85/18.05 S/S 7-#6
5 18.05/23.26 S/S 7-#6
6 23.26/28.46 S/S 7-#6
7 28.46/33.01 S/S 7-#6
8 33.01/36.07 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.30 H/S 7-#6
2 5.30/10.70 S/S 7-#6
3 10.70/15.65 S/S 7-#6
4 15.65/20.51 S/S 7-#6
5 20.51/25.71 S/S 7-#6
6 25.71/30.86 S/S 7-#6
7 30.86/36.07 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 5.08 None 13-#6
3 5.08/10.28 None 15-#6
4 10.28/15.45 None 15-#6
5 15.45/20.66 B62 None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 8/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.66/25.86 None 15-#6
7 25.86/31.06 None 15-#6
8 31.06/35.26 None 12-#6
9 35.26/36.07 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 35.39/36.07 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.13, 12.47) to (4.10, 12.47) 3.09 3975.00x250.01 Wall 0.00
(4.10, 12.47) to (9.30, 12.47) 7.67 5199.99x250.01 Wall 0.00
(9.30, 12.47) to (14.50, 12.47) 12.87 5199.99x250.01 Wall 0.00
(14.50, 12.47) to (19.70, 12.47) 18.07 5199.99x250.01 Wall 0.00
(19.70, 12.47) to (24.90, 12.47) 23.27 5199.99x250.01 Wall 0.00
(24.90, 12.47) to (30.10, 12.47) 28.47 5199.99x250.01 Wall 0.00
(30.10, 12.47) to (34.00, 12.47) 33.02 3899.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 105.65 1 35.39
Provided Shear (kN) 671.55 35.39
Req. Max Pos. Moment (kNm) 215.51 1 31.07 243.56 1 20.66
Provided Pos. Moment (kNm) 335.06 31.07 685.55 20.66
Req. Max Neg. Moment (kNm) -149.83 160 15.47 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 15.47 -0.00 0.00
Req. Max Punching Shear (kN) 972.11 1 28.47
Provided Punching Shear (kN) 4605.92 28.47
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 82.3 Ld Co # 514
Max Average Unfactored Soil Bearing (kN/m2) 68.2

B63
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 9/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 6
Length (m): 3.20
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.60 H/S 7-#6
2 1.60/ 3.20 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.20 H/S 7-#6
2 1.20/ 2.00 S/S 7-#6
3 2.00/ 3.20 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 2.40 None 5-#6
3 2.40/ 3.20 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 2.51/ 3.20 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

B64
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 10/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(34.00, 11.48) to (34.00, 12.47) 1.60 1000.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 65.96 135 0.69
Provided Shear (kN) 671.55 0.69
Req. Max Pos. Moment (kNm) 61.00 135 1.10 25.92 1 0.80
Provided Pos. Moment (kNm) 335.06 1.10 228.21 0.80
Req. Max Neg. Moment (kNm) -0.00 136 3.20 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 3.20 -0.00 0.00
Req. Max Punching Shear (kN) 197.27 135 1.60
Provided Punching Shear (kN) 2373.59 1.60
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 34.1 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 30.0

B65
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 11/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 4
Length (m): 3.20
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.60 H/S 7-#6
2 1.60/ 3.20 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.20 H/S 7-#6
2 1.20/ 2.00 S/S 7-#6
3 2.00/ 3.20 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 2.40 None 5-#6
3 2.40/ 3.20 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 2.51/ 3.20 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

B66
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 12/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(34.00, 0.13) to (34.00, 1.12) 1.60 1000.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 55.75 153 0.69
Provided Shear (kN) 671.55 0.69
Req. Max Pos. Moment (kNm) 51.44 153 1.10 23.86 1 0.80
Provided Pos. Moment (kNm) 335.06 1.10 228.21 0.80
Req. Max Neg. Moment (kNm) -0.00 72 3.20 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 3.20 -0.00 0.00
Req. Max Punching Shear (kN) 167.92 153 1.60
Provided Punching Shear (kN) 2373.59 1.60
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 29.5 Ld Co # 517
Max Average Unfactored Soil Bearing (kN/m2) 27.8

B67
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 13/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 5
Length (m): 7.40
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.70 H/S 7-#6
2 3.70/ 7.40 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 2.75 H/S 7-#6
2 2.75/ 4.65 S/S 7-#6
3 4.65/ 7.40 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 6.60 None 17-#6
3 6.60/ 7.40 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 6.71/ 7.40 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

B68
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 14/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(34.00, 1.12) to (39.20, 1.12) 3.70 5199.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 89.03 155 6.71
Provided Shear (kN) 671.55 6.71
Req. Max Pos. Moment (kNm) 80.89 155 6.30 134.70 1 0.80
Provided Pos. Moment (kNm) 335.06 6.30 776.76 0.80
Req. Max Neg. Moment (kNm) -0.00 61 0.00 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 0.00 -0.00 0.00
Req. Max Punching Shear (kN) 624.46 1 3.70
Provided Punching Shear (kN) 4605.92 3.70
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 42.7 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 42.1

B69
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 15/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 9
Length (m): 41.94
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.80 H/S 7-#6
2 2.80/ 7.05 S/S 7-#6
3 7.05/12.25 S/S 7-#6
4 12.25/17.45 S/S 7-#6
5 17.45/25.26 S/S 7-#6
6 25.26/33.06 S/S 7-#6
7 33.06/38.26 S/S 7-#6
8 38.26/41.94 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.85 H/S 7-#6
2 4.85/ 9.80 S/S 7-#6
3 9.80/15.05 S/S 7-#6
4 15.05/21.16 S/S 7-#6
5 21.16/29.36 S/S 7-#6
6 29.36/35.66 S/S 7-#6
7 35.66/41.94 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 4.45 None 11-#6
3 4.45/ 9.65 None 15-#6
4 9.65/14.85 None 15-#6
5 14.85/20.06 B70 None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 16/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.06/25.01 None 15-#6
7 25.01/30.46 None 16-#6
8 30.46/35.66 None 15-#6
9 35.66/41.16 None 16-#6
10 41.16/41.94 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 41.26/41.94 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(39.73, 0.13) to (43.10, 0.13) 2.78 3369.01x250.01 Wall 0.00
(43.10, 0.13) to (48.30, 0.13) 7.07 5199.99x250.01 Wall 0.00
(48.30, 0.13) to (53.50, 0.13) 12.27 5199.99x250.01 Wall 0.00
(53.50, 0.13) to (58.70, 0.13) 17.47 5199.99x250.01 Wall 0.00
(58.70, 0.13) to (63.65, 0.13) 22.54 4950.00x250.01 Wall 0.00
(63.65, 0.13) to (69.10, 0.13) 27.74 5450.00x250.01 Wall 0.00
(69.10, 0.13) to (74.30, 0.13) 33.07 5199.99x250.01 Wall 0.00
(74.30, 0.13) to (79.47, 0.13) 38.26 5175.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 90.81 145 0.69
Provided Shear (kN) 671.55 0.69
Req. Max Pos. Moment (kNm) 131.44 1 4.47 214.91 1 25.01
Provided Pos. Moment (kNm) 335.06 4.47 731.04 25.01
Req. Max Neg. Moment (kNm) -115.87 1 20.07 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 20.07 -0.00 0.00
Req. Max Punching Shear (kN) 779.51 1 27.74
Provided Punching Shear (kN) 4751.15 27.74
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 68.3 Ld Co # 555
Max Average Unfactored Soil Bearing (kN/m2) 62.2

B71
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 17/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 10
Length (m): 41.94
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.80 H/S 7-#6
2 2.80/ 7.05 S/S 7-#6
3 7.05/12.25 S/S 7-#6
4 12.25/17.45 S/S 7-#6
5 17.45/25.26 S/S 7-#6
6 25.26/33.06 S/S 7-#6
7 33.06/38.26 S/S 7-#6
8 38.26/41.94 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.85 H/S 7-#6
2 4.85/ 9.80 S/S 7-#6
3 9.80/15.05 S/S 7-#6
4 15.05/21.16 S/S 7-#6
5 21.16/29.36 S/S 7-#6
6 29.36/35.66 S/S 7-#6
7 35.66/41.94 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 4.45 None 11-#6
3 4.45/ 9.65 None 15-#6
4 9.65/14.85 None 15-#6
5 14.85/20.06 B72 None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 18/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.06/25.01 None 15-#6
7 25.01/30.46 None 16-#6
8 30.46/35.66 None 15-#6
9 35.66/41.16 None 16-#6
10 41.16/41.94 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 41.26/41.94 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(39.73, 12.48) to (43.10, 12.47) 2.78 3369.01x250.01 Wall 0.00
(43.10, 12.47) to (48.30, 12.47) 7.07 5199.99x250.01 Wall 0.00
(48.30, 12.47) to (53.50, 12.47) 12.27 5199.99x250.01 Wall 0.00
(53.50, 12.47) to (58.70, 12.47) 17.47 5199.99x250.01 Wall 0.00
(58.70, 12.47) to (63.65, 12.47) 22.54 4950.00x250.01 Wall 0.00
(63.65, 12.47) to (69.10, 12.47) 27.74 5450.00x250.01 Wall 0.00
(69.10, 12.47) to (74.30, 12.47) 33.07 5199.99x250.01 Wall 0.00
(74.30, 12.47) to (79.47, 12.47) 38.26 5175.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 90.81 160 0.69
Provided Shear (kN) 671.55 0.69
Req. Max Pos. Moment (kNm) 131.44 1 4.47 214.91 1 25.01
Provided Pos. Moment (kNm) 335.06 4.47 731.04 25.01
Req. Max Neg. Moment (kNm) -115.87 1 20.07 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 20.07 -0.00 0.00
Req. Max Punching Shear (kN) 779.51 1 27.74
Provided Punching Shear (kN) 4751.15 27.74
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 68.3 Ld Co # 505
Max Average Unfactored Soil Bearing (kN/m2) 62.2

B73
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 19/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 1
Length (m): 36.07
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.10 H/S 7-#6
2 3.10/ 7.65 S/S 7-#6
3 7.65/12.85 S/S 7-#6
4 12.85/18.05 S/S 7-#6
5 18.05/23.26 S/S 7-#6
6 23.26/28.46 S/S 7-#6
7 28.46/33.01 S/S 7-#6
8 33.01/36.07 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.30 H/S 7-#6
2 5.30/10.70 S/S 7-#6
3 10.70/15.65 S/S 7-#6
4 15.65/20.51 S/S 7-#6
5 20.51/25.71 S/S 7-#6
6 25.71/30.86 S/S 7-#6
7 30.86/36.07 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 5.08 None 13-#6
3 5.08/10.28 None 15-#6
4 10.28/15.45 None 15-#6
5 15.45/20.66 B74 None 15-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 20/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 20.66/25.86 None 15-#6
7 25.86/31.06 None 15-#6
8 31.06/35.26 None 12-#6
9 35.26/36.07 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 35.39/36.07 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.13, 0.13) to (4.10, 0.13) 3.09 3975.00x250.01 Wall 0.00
(4.10, 0.13) to (9.30, 0.13) 7.67 5199.99x250.01 Wall 0.00
(9.30, 0.13) to (14.50, 0.13) 12.87 5199.99x250.01 Wall 0.00
(14.50, 0.13) to (19.70, 0.13) 18.07 5199.99x250.01 Wall 0.00
(19.70, 0.13) to (24.90, 0.13) 23.27 5199.99x250.01 Wall 0.00
(24.90, 0.13) to (30.10, 0.13) 28.47 5199.99x250.01 Wall 0.00
(30.10, 0.13) to (34.00, 0.13) 33.02 3899.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 99.38 159 35.39
Provided Shear (kN) 671.55 35.39
Req. Max Pos. Moment (kNm) 185.92 1 31.07 242.16 1 20.66
Provided Pos. Moment (kNm) 335.06 31.07 685.55 20.66
Req. Max Neg. Moment (kNm) -146.21 145 15.47 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 15.47 -0.00 0.00
Req. Max Punching Shear (kN) 967.41 1 23.27
Provided Punching Shear (kN) 4605.92 23.27
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 81.3 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 67.4

B75
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 21/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 12
Length (m): 14.56
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 92.46º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 5.40 H/S 7-#6
2 5.40/ 9.15 S/S 7-#6
3 9.15/14.56 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 5.40 H/S 7-#6
2 5.40/ 9.15 S/S 7-#6
3 9.15/14.56 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.80 None 3-#6
2 0.80/ 2.10 None 4-#6
3 2.10/12.45 None 30-#6
4 12.45/13.75 None 4-#6
5 13.75/14.56 None 3-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.69 Not Applic. None
2 13.88/14.56 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
B76
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 22/22
RSLF - Artillery Brigade
DataBase: Battalion Headquarters Date: 05/15/19 13:49:22
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(39.73, 0.13) to (39.73, 12.48) 7.27 12349.99x150.01 Wall 2.46
(39.20, 0.13) to (39.20, 1.12) 1.62 1000.00x250.01 Wall 2.46
(39.20, 1.12) to (39.20, 11.48) 7.29 10349.99x150.01 Wall 2.46
(39.20, 11.48) to (39.20, 12.47) 12.96 1000.00x250.01 Wall 2.46
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 86.36 142 13.88
Provided Shear (kN) 671.55 13.88
Req. Max Pos. Moment (kNm) 82.05 159 1.10 371.11 1 2.10
Provided Pos. Moment (kNm) 335.06 1.10 1371.00 2.10
Req. Max Neg. Moment (kNm) -0.00 4 14.56 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 14.56 -0.00 0.00
Req. Max Punching Shear (kN) 1091.68 150 7.27
Provided Punching Shear (kN) 7441.68 7.27
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 66.9 Ld Co # 506
Max Average Unfactored Soil Bearing (kN/m2) 52.6

B77
B78
B79
B80
FOR CMU WALL DESIGN
SEE FIRE PUMP HOUSE (BUILDING E)

B81
B82
SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
C. Company Headquarters

Building Design PAGE NO.

RAM Calculation Check……………………………………………………………………………………… C1 - C2

RAM Modeler………………………………….……..………………………………………………………… C3 - C3

RAM Frame Analysis - Loads and Applied Forces………………………………………………….…..… C 4 - C 22

RAM Concrete Pedestal Design……………………………………….………..…………………………… C 23 - C 26

RAM Concrete Analysis - Wall Forces……………………………………….………..…………………… C 27 - C 31

RAM Concrete Stem Wall……………………………………...…………..………………………………… C 32 - C 52

RAM Foundation - Spread Footing Design………………..……………..………………………………… C 53 - C 53

RAM Foundation - Continuous Footing Design………………..……………..…………………………… C 54 - C 82

Slab on Grade Design…………………………………………….…..……..…….…………………………… C 83 - C 84

CMU Wall Design…………………………………………….…..……..…….………………………………… C 85 - C 86


C1
C2
RAM Structural System V16.00.00.28. - Floor Plan: STEM
DataBase: Company Headquarters 04/24/19 12:57:05

G
F
E

C3
A

1 2 3 4 5A
5 7
6 8 9 10 10A 11 12A
12 13
Loads and Applied Forces

RAM Frame 16.00.00.28


DataBase: Company Headquarters 05/07/19 13:33:52

LOAD CASE: WIND


ASCE 7-16
Exposure: C
Basic Wind Speed (km/h): 185.0
Apply Directionality Factor, Kd = 0.85
Use Topography Factor, Kzt: 1.00
Ground Elevation Factor, Ke: 1.00
Use Calculated Frequency for X-Dir.
Use Calculated Frequency for Y-Dir.
Gust Factor for Rigid Structures, G: Use Calculated G for X-Dir.
Gust Factor for Rigid Structures, G: Use Calculated G for Y-Dir.
Damping Ratio for Flexible Structures= 0.01
Mean Roof Height (m): Top Story Height + Parapet = 5.60
Ground Level: STEM
WIND PRESSURES:
X-Direction: Natural Frequency = 18.121 Structure is Rigid
Y-Direction: Natural Frequency = 10.713 Structure is Rigid
CpWindward = 0.80 qLeeward (qh) = 1.22 kN/m2
GCpn (Parapet): Windward = 1.50 Leeward = -1.00
Height Kz Kzt qz Gust Factor G CpLeeward Pressure (kN/m2)
m kN/m2 X Y X Y X Y
5.60 0.886 1.000 1.220 ---- ---- ---- ---- 3.049 3.049
4.00 0.849 1.000 1.169 0.873 0.842 -0.256 -0.500 1.089 1.300
5.60 0.886 1.000 1.220 ---- ---- ---- ---- 3.049 3.049
4.00 0.849 1.000 1.169 0.873 0.842 -0.256 -0.500 1.089 1.300
0.00 0.849 1.000 1.169 0.873 0.842 -0.256 -0.500 1.089 1.300

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_X
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 119.77 0.00 12.71 12.34
ROOF 2 4.00 147.82 0.00 42.94 10.35

APPLIED STORY FORCES


Type: Wind_ASCE716_1_X
Level Ht Fx Fy
m kN kN
ROOF 4.00 267.59 0.00
_________ _________
267.59 0.00

C4
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 2/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_1_Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 192.04 12.71 12.34
ROOF 2 4.00 0.00 260.11 42.94 10.35

APPLIED STORY FORCES


Type: Wind_ASCE716_1_Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 452.15
_________ _________
0.00 452.15

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 89.83 0.00 12.71 14.88
ROOF 2 4.00 110.87 0.00 42.94 13.49

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X+E
Level Ht Fx Fy
m kN kN
ROOF 4.00 200.70 0.00
_________ _________
200.70 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_X-E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 89.83 0.00 12.71 9.79
ROOF 2 4.00 110.87 0.00 42.94 7.21

APPLIED STORY FORCES


Type: Wind_ASCE716_2_X-E
Level Ht Fx Fy
m kN kN
ROOF 4.00 200.70 C5 0.00
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 3/19


DataBase: Company Headquarters 05/07/19 13:33:52
_________ _________
200.70 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y+E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 144.03 16.56 12.34
ROOF 2 4.00 0.00 195.08 48.15 10.35

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y+E
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 339.11
_________ _________
0.00 339.11

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_2_Y-E
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 144.03 8.86 12.34
ROOF 2 4.00 0.00 195.08 37.72 10.35

APPLIED STORY FORCES


Type: Wind_ASCE716_2_Y-E
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 339.11
_________ _________
0.00 339.11

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X+Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 89.83 144.03 12.71 12.34
ROOF 2 4.00 110.87 195.08 42.94 10.35

C6
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 4/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X+Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 200.70 339.11
_________ _________
200.70 339.11

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_3_X-Y
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 89.83 -144.03 12.71 12.34
ROOF 2 4.00 110.87 -195.08 42.94 10.35

APPLIED STORY FORCES


Type: Wind_ASCE716_3_X-Y
Level Ht Fx Fy
m kN kN
ROOF 4.00 200.70 -339.11
_________ _________
200.70 -339.11

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 67.37 108.02 8.86 14.88
ROOF 2 4.00 83.15 146.31 37.72 13.49

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CW
Level Ht Fx Fy
m kN kN
ROOF 4.00 150.52 254.34
_________ _________
150.52 254.34

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Diaph.# Ht C7 Fx Fy X Y
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 5/19


DataBase: Company Headquarters 05/07/19 13:33:52
m kN kN m m
ROOF 1 4.00 67.37 108.02 16.56 9.79
ROOF 2 4.00 83.15 146.31 48.15 7.21

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X+Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 4.00 150.52 254.34
_________ _________
150.52 254.34

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 67.37 -108.02 16.56 14.88
ROOF 2 4.00 83.15 -146.31 48.15 13.49

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CW
Level Ht Fx Fy
m kN kN
ROOF 4.00 150.52 -254.34
_________ _________
150.52 -254.34

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 67.37 -108.02 8.86 9.79
ROOF 2 4.00 83.15 -146.31 37.72 7.21

APPLIED STORY FORCES


Type: Wind_ASCE716_4_X-Y_CCW
Level Ht Fx Fy
m kN kN
ROOF 4.00 150.52 -254.34
_________ _________
150.52 -254.34
C8
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 6/19


DataBase: Company Headquarters 05/07/19 13:33:52

LOAD CASE: SEIS


Seismic ASCE 7-16 Equivalent Lateral Force
Site Class: D Importance Factor: 1.50 Ss: 0.370 g S1: 0.170 g TL: 12.00 s
Fa: 1.504 Fv: 2.260 SDs: 0.371 g SD1: 0.256 g
Seismic Design Category: D
Provisions for: Force
Ground Level: STEM

Dir Eccent R Ta Equation Building Period-T


X + And - 4.0 User Defined Use Ta
Y + And - 4.0 User Defined Use Ta

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
X 0.177 1.444 0.177 0.177 0.139 0.543 0.024 0.139 1.000

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
Y 0.177 1.444 0.177 0.177 0.139 0.543 0.024 0.139 1.000

Total Building Weight (kN) = 19217.47

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 0.00 19.53 13.25
ROOF 2 4.00 1552.53 0.00 43.13 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 0.00
_________ _________
2673.53 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 0.00 19.53 11.55
ROOF 2 4.00 C9 1552.53 0.00 43.13 10.55
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 7/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 0.00
_________ _________
2673.53 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 1121.01 20.81 12.40
ROOF 2 4.00 0.00 1552.53 44.86 11.59

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 2673.53
_________ _________
0.00 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 0.00 1121.01 18.24 12.40
ROOF 2 4.00 0.00 1552.53 41.39 11.59

APPLIED STORY FORCES


Type: EQ_ASCE716_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 0.00 2673.53
_________ _________
0.00 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Diaph.# Ht C10 Fx Fy X Y
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 8/19


DataBase: Company Headquarters 05/07/19 13:33:52
m kN kN m m
ROOF 1 4.00 1121.01 336.30 20.81 13.25
ROOF 2 4.00 1552.53 465.76 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 802.06
_________ _________
2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 -336.30 20.81 13.25
ROOF 2 4.00 1552.53 -465.76 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 -802.06
_________ _________
2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 336.30 20.81 13.25
ROOF 2 4.00 -1552.53 465.76 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 802.06
_________ _________
-2673.53 802.06
C11
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 9/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 -336.30 20.81 13.25
ROOF 2 4.00 -1552.53 -465.76 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 -802.06
_________ _________
-2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 1121.01 20.81 13.25
ROOF 2 4.00 465.76 1552.53 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 2673.53
_________ _________
802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 -1121.01 20.81 13.25
ROOF 2 4.00 465.76 -1552.53 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 C12 -2673.53
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 10/19


DataBase: Company Headquarters 05/07/19 13:33:52
_________ _________
802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 1121.01 20.81 13.25
ROOF 2 4.00 -465.76 1552.53 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 2673.53
_________ _________
-802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 -1121.01 20.81 13.25
ROOF 2 4.00 -465.76 -1552.53 44.86 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 -2673.53
_________ _________
-802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 336.30 18.24 13.25
ROOF 2 4.00 1552.53 465.76 41.39 12.64

C13
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 11/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 802.06
_________ _________
2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 -336.30 18.24 13.25
ROOF 2 4.00 1552.53 -465.76 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 -802.06
_________ _________
2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 336.30 18.24 13.25
ROOF 2 4.00 -1552.53 465.76 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 802.06
_________ _________
-2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
Level Diaph.# Ht C14 Fx Fy X Y
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 12/19


DataBase: Company Headquarters 05/07/19 13:33:52
m kN kN m m
ROOF 1 4.00 -1121.01 -336.30 18.24 13.25
ROOF 2 4.00 -1552.53 -465.76 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 -802.06
_________ _________
-2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 1121.01 18.24 13.25
ROOF 2 4.00 465.76 1552.53 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 2673.53
_________ _________
802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 -1121.01 18.24 13.25
ROOF 2 4.00 465.76 -1552.53 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 -2673.53
_________ _________
802.06 -2673.53
C15
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 13/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 1121.01 18.24 13.25
ROOF 2 4.00 -465.76 1552.53 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 2673.53
_________ _________
-802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 -1121.01 18.24 13.25
ROOF 2 4.00 -465.76 -1552.53 41.39 12.64

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 -2673.53
_________ _________
-802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 336.30 20.81 11.55
ROOF 2 4.00 1552.53 465.76 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 C16 802.06
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 14/19


DataBase: Company Headquarters 05/07/19 13:33:52
_________ _________
2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 -336.30 20.81 11.55
ROOF 2 4.00 1552.53 -465.76 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 -802.06
_________ _________
2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 336.30 20.81 11.55
ROOF 2 4.00 -1552.53 465.76 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 802.06
_________ _________
-2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 -336.30 20.81 11.55
ROOF 2 4.00 -1552.53 -465.76 44.86 10.55

C17
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 15/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 -802.06
_________ _________
-2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 1121.01 20.81 11.55
ROOF 2 4.00 465.76 1552.53 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 2673.53
_________ _________
802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 -1121.01 20.81 11.55
ROOF 2 4.00 465.76 -1552.53 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 -2673.53
_________ _________
802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Diaph.# Ht C18 Fx Fy X Y
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 16/19


DataBase: Company Headquarters 05/07/19 13:33:52
m kN kN m m
ROOF 1 4.00 -336.30 1121.01 20.81 11.55
ROOF 2 4.00 -465.76 1552.53 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 2673.53
_________ _________
-802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 -1121.01 20.81 11.55
ROOF 2 4.00 -465.76 -1552.53 44.86 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 -2673.53
_________ _________
-802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 336.30 18.24 11.55
ROOF 2 4.00 1552.53 465.76 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 802.06
_________ _________
2673.53 802.06
C19
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 17/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 1121.01 -336.30 18.24 11.55
ROOF 2 4.00 1552.53 -465.76 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 2673.53 -802.06
_________ _________
2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 336.30 18.24 11.55
ROOF 2 4.00 -1552.53 465.76 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 802.06
_________ _________
-2673.53 802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -1121.01 -336.30 18.24 11.55
ROOF 2 4.00 -1552.53 -465.76 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -2673.53 C20 -802.06
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 18/19


DataBase: Company Headquarters 05/07/19 13:33:52
_________ _________
-2673.53 -802.06

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 1121.01 18.24 11.55
ROOF 2 4.00 465.76 1552.53 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 2673.53
_________ _________
802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 336.30 -1121.01 18.24 11.55
ROOF 2 4.00 465.76 -1552.53 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 802.06 -2673.53
_________ _________
802.06 -2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 1121.01 18.24 11.55
ROOF 2 4.00 -465.76 1552.53 41.39 10.55

C21
Loads and Applied Forces

RAM Frame 16.00.00.28 Page 19/19


DataBase: Company Headquarters 05/07/19 13:33:52

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 2673.53
_________ _________
-802.06 2673.53

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kN kN m m
ROOF 1 4.00 -336.30 -1121.01 18.24 11.55
ROOF 2 4.00 -465.76 -1552.53 41.39 10.55

APPLIED STORY FORCES


Type: EQ_ASCE716_-0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kN kN
ROOF 4.00 -802.06 -2673.53
_________ _________
-802.06 -2673.53

C22
Concrete Column Design
RAM Concrete Column v16.00.00.28
Database: Company Headquarters 05/08/19 10:44:43
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 2 Grid Location: (24.92m-4.00m)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.77
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 449.80
Moment Top Major(kNm) 24.32
Minor(kNm) 58.21
Moment Bottom Major(kNm) -12.25
Minor(kNm) -28.84
Calculated Parameters (Angle = 67.32 degrees): Ld/Cap = 0.47
0.65 Pn(kN): 449.80
0.65 Mn Major(kNm): 51.22 0.65 Mn Minor(kNm): 122.60
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 449.80 449.80
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28
TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (2) 1.200 D + 1.600 Rfp
C23
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 2/4
Database: Company Headquarters 05/08/19 10:44:43
Building Code: IBC Concrete Code: ACI 318-14
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 2 84.65 148.07 162.06 0.75 232.59 0.36
1 Minor: 2 84.65 148.07 162.06 0.75 232.59 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 186.01 84.65 186.01 84.65
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

C24
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 3/4
Database: Company Headquarters 05/08/19 10:44:43
Building Code: IBC Concrete Code: ACI 318-14

COLUMN INFORMATION:
Level STEM
Column Number: 1 Grid Location: (17.73m-4.00m)
Size: 400 x 400 Depth x Width (mm) 400.00x400.00
Reinforcement
Longitudinal: 8-#5 (3 x 1) As (mm²) 1600.00 (1.00%)
Transverse: #3@150.00 0.00-1000.00

Confinement Tie Clear Cover (mm) 40.00


Shear Legs Major 2 Shear Legs Minor 2
Longitudinal Bars Max Tension Stress Ratio: 0.77
MATERIAL PROPERTIES:
f'c (N/mm2): 30.00 fy Long (N/mm2): 500.00
fct (N/mm2): 0.00 fyt Trans (N/mm2): 500.00
Conc. Weight (kg/m3): 2350.00 Conc. Type: NWC
Conc. Modulus (N/mm2): 26668.78 Reinf. Modulus (N/mm2): 199948.04
DESIGN PARAMETERS:
Major Minor
Unbraced Length (m) 5.00 5.00
K 1.91 1.91
Braced Against Sidesway No No
LONGITUDINAL REINFORCEMENT:
Controlling Load Combination: (1) 1.400 D
Axial Load (kN) 449.80
Moment Top Major(kNm) 24.32
Minor(kNm) -58.20
Moment Bottom Major(kNm) -12.25
Minor(kNm) 28.80
Calculated Parameters (Angle = 67.32 degrees): Ld/Cap = 0.47
0.65 Pn(kN): 449.80
0.65 Mn Major(kNm): 51.23 0.65 Mn Minor(kNm): 122.59
Major Minor
Kl/r 82.71 82.71
Slender Yes Yes
Slenderness:
Pu (kN) 449.80 449.80
Combination 1 1
Cm 0.40 0.40
ns 1.00 1.00
d 1.00 1.00
Pc (kN) 1231.17 1231.17
Ig (mm^4) 2133333270.28 2133333270.28
TRANSVERSE REINFORCEMENT:
Controlling Load Combination: (2) 1.200 D + 1.600 Rfp
C25
Concrete Column Design
RAM Concrete Column v16.00.00.28 Page 4/4
Database: Company Headquarters 05/08/19 10:44:43
Building Code: IBC Concrete Code: ACI 318-14
LC Vu (kN) Vc (kN) Vs (kN)  (Vc + Vs) (kN) Ld/Cap
1 Major: 2 84.65 148.07 162.06 0.75 232.59 0.36
1 Minor: 2 84.65 148.07 162.06 0.75 232.59 0.36
SPECIAL PROVISIONS - :
Major Minor
Mn (kNm) Vu (kN) Mn (kNm) Vu (kN)
At Column 186.01 84.65 186.01 84.65
TORSION CAPACITY:
0.75 Tn (kNm) 0.00 Tu (kNm) 0.00

C26
Wall Forces
RAM Concrete Analysis v16.00.00.28
Database: Company Headquarters 05/07/19 13:35:20
Building Code: IBC Concrete Code: ACI 318-14

Story: ROOF
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 225.88 -23.92 4.56 -0.38 1.81
Roof Live Load 8.50 -2.96 1.07 -0.04 0.15

2 Dead Load 2001.19 1205.97 -8.61 -0.03 -0.36


Roof Live Load 155.93 79.58 -0.39 -0.02 0.06

3 Dead Load 43.63 -0.40 -1.27 0.04 -0.13


Roof Live Load 1.68 -0.05 -0.18 0.01 -0.02

4 Dead Load 227.04 -15.06 2.60 -0.48 2.50


Roof Live Load 9.16 -2.27 0.45 -0.05 0.24

5 Dead Load 56.13 -8.26 -16.35 0.01 -0.02


Roof Live Load 3.85 -1.10 -2.24 -0.00 0.00

6 Dead Load 1461.53 92.62 11.64 -0.11 0.80


Roof Live Load 102.80 14.78 1.33 0.01 -0.01

7 Dead Load 167.40 5.44 -12.18 -0.28 0.78


Roof Live Load 9.45 1.24 -1.95 -0.05 0.17

8 Dead Load 2019.00 66.86 17.88 0.00 0.24


Roof Live Load 232.39 12.15 1.83 0.01 -0.01

9 Dead Load 258.25 -48.79 3.46 0.28 -0.98


Roof Live Load 11.91 0.62 0.23 0.03 -0.11

10 Dead Load 155.82 -15.73 8.72 0.20 -0.81


Roof Live Load 8.82 -3.07 0.66 0.02 -0.09

11 Dead Load 284.42 -99.87 15.89 -0.45 1.95


Roof Live Load 7.83 -11.09 3.19 -0.04 0.18

12 Dead Load 3272.88 -49.20 -1.41 -0.11 -0.39


Roof Live Load 263.85 -4.90 -0.34 -0.04 0.09

13 Dead Load 181.36 83.50 -20.09 -0.31 1.19


Roof Live Load 12.47 12.98 -3.13 -0.04 0.16

14 Dead Load 313.85 -52.43 8.63 -0.54 1.97


Roof Live Load 23.39 -6.11 0.53 -0.07 0.27

15 Dead Load 5428.40 -123.93


C27 -27.17 0.06 0.05
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 2/5
Database: Company Headquarters 05/07/19 13:35:20
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 708.95 -17.99 -3.69 0.01 -0.04

16 Dead Load 3996.70 -333.41 -15.32 0.18 0.06


Roof Live Load 480.77 -56.02 -2.10 0.06 -0.15

17 Dead Load 215.82 8.01 -29.46 0.96 -2.73


Roof Live Load 18.81 1.51 -4.75 0.14 -0.44

18 Dead Load 54.26 1.08 3.67 0.15 -0.52


Roof Live Load 3.06 0.13 0.51 0.03 -0.09

19 Dead Load 90.45 17.19 34.71 0.03 -0.09


Roof Live Load 9.01 2.38 4.90 0.00 -0.01

20 Dead Load 390.29 -60.26 16.27 0.49 -2.84


Roof Live Load 11.89 -5.44 2.87 0.05 -0.26

21 Dead Load 450.62 -6.88 9.65 1.01 -5.05


Roof Live Load 27.32 1.68 1.50 0.14 -0.63

Story: STEM
Wall No Case Axial Mmajor Vmajor Mminor Vminor
(kN) (kNm) (kN) (kNm) (kN)
1 Dead Load 126.55 -6.91 -0.43 -1.00 2.74
Roof Live Load 5.55 -0.66 0.22 -0.06 0.18

2 Dead Load 410.56 46.82 -11.68 0.79 -2.00


Roof Live Load 27.89 7.19 -1.19 0.03 -0.07

3 Dead Load 141.16 2.05 3.13 -0.59 1.79


Roof Live Load 4.69 0.05 0.13 -0.02 0.08

4 Dead Load 51.26 0.13 -0.39 0.13 -0.41


Roof Live Load 1.93 0.02 -0.08 0.02 -0.06

5 Dead Load 274.26 -18.95 2.41 -1.96 5.20


Roof Live Load 11.75 -3.04 0.39 -0.12 0.34

6 Dead Load 64.17 -1.03 -3.50 0.07 -0.11


Roof Live Load 4.11 -0.08 -0.36 -0.00 0.01

7 Dead Load 336.59 26.29 -8.46 -0.70 1.84


Roof Live Load 19.53 4.70 -0.80 -0.02 0.06

8 Dead Load 191.22 C28 9.07 -4.21 0.30 -0.82


Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 3/5
Database: Company Headquarters 05/07/19 13:35:20
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 10.18 1.79 -0.67 -0.02 0.08

9 Dead Load 341.30 64.60 -13.88 -0.40 1.06


Roof Live Load 33.37 10.90 -2.17 -0.02 0.05

10 Dead Load 440.75 4.26 -0.27 -0.01 0.00


Roof Live Load 33.39 0.50 -0.02 -0.00 0.00

11 Dead Load 497.15 10.20 -1.99 -0.01 0.00


Roof Live Load 55.69 1.76 -0.31 -0.00 0.00

12 Dead Load 350.03 1.49 -0.38 0.01 -0.00


Roof Live Load 23.12 0.28 -0.02 0.00 -0.00

13 Dead Load 466.06 23.89 -2.49 -0.01 0.00


Roof Live Load 35.04 1.39 -0.14 -0.00 0.00

14 Dead Load 504.55 -0.13 -0.02 -0.00 -0.00


Roof Live Load 56.96 -0.03 -0.01 -0.00 -0.00

15 Dead Load 350.90 0.02 0.18 0.00 -0.00


Roof Live Load 23.28 -0.01 0.02 0.00 -0.00

16 Dead Load 500.39 -10.21 2.84 -0.01 0.01


Roof Live Load 36.37 -1.40 0.29 -0.00 0.00

17 Dead Load 491.13 -17.52 3.48 -0.00 0.00


Roof Live Load 54.67 -2.95 0.52 -0.00 0.00

18 Dead Load 347.73 -4.34 1.64 0.01 -0.01


Roof Live Load 22.77 -0.67 0.15 0.00 -0.00

19 Dead Load 314.82 0.04 11.67 0.74 -1.67


Roof Live Load 20.75 -0.98 1.02 0.03 -0.06

20 Dead Load 260.26 -27.26 14.71 0.02 -0.04


Roof Live Load 25.22 -4.74 1.98 0.00 -0.01

21 Dead Load 217.71 -1.24 7.77 -0.62 1.49


Roof Live Load 12.83 -0.71 0.61 -0.03 0.07

22 Dead Load 308.60 -46.36 -2.25 0.80 -2.36


Roof Live Load 14.75 1.28 -0.37 0.06 -0.19

23 Dead Load 186.28 -17.28 5.31 0.64 -1.85


C29
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 4/5
Database: Company Headquarters 05/07/19 13:35:20
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 10.65 -3.23 0.61 0.05 -0.15

24 Dead Load 344.75 -108.76 3.06 -1.22 3.38


Roof Live Load 10.51 -12.00 0.54 -0.08 0.24

25 Dead Load 530.67 79.11 -16.78 0.89 -2.14


Roof Live Load 37.53 10.46 -1.63 0.03 -0.07

26 Dead Load 227.91 104.83 -15.84 -0.76 2.36


Roof Live Load 16.36 15.67 -2.44 -0.09 0.29

27 Dead Load 392.73 -90.31 10.92 -1.29 3.98


Roof Live Load 30.59 -10.42 1.19 -0.15 0.47

28 Dead Load 794.68 249.08 -42.00 -0.00 0.01


Roof Live Load 97.88 37.31 -5.90 0.00 0.00

29 Dead Load 657.14 73.74 -21.09 -0.81 1.82


Roof Live Load 72.64 12.83 -2.77 -0.06 0.11

30 Dead Load 593.67 3.84 -0.40 -0.01 0.00


Roof Live Load 46.01 0.52 -0.01 -0.00 0.00

31 Dead Load 996.36 13.22 -0.34 0.00 -0.00


Roof Live Load 128.75 2.07 -0.04 0.00 -0.00

32 Dead Load 715.68 3.49 -0.64 0.01 -0.01


Roof Live Load 83.05 0.63 -0.05 0.00 -0.00

33 Dead Load 595.34 -0.20 0.33 -0.00 0.00


Roof Live Load 46.25 -0.02 0.05 -0.00 0.00

34 Dead Load 1002.63 -0.47 1.35 -0.00 -0.00


Roof Live Load 129.76 -0.07 0.21 -0.00 -0.00

35 Dead Load 717.14 -0.22 0.19 0.00 0.00


Roof Live Load 83.33 -0.03 0.04 0.00 -0.00

36 Dead Load 595.35 0.20 -0.37 -0.00 0.00


Roof Live Load 46.25 0.02 -0.05 -0.00 -0.00

37 Dead Load 1002.77 0.36 -1.61 -0.00 -0.00


Roof Live Load 129.78 0.05 -0.24 -0.00 -0.00

38 Dead Load 717.28 0.26 -0.55 0.00 0.00


C30
Wall Forces
RAM Concrete Analysis v16.00.00.28 Page 5/5
Database: Company Headquarters 05/07/19 13:35:20
Building Code: IBC Concrete Code: ACI 318-14
Wall No Case Axial Mmajor Vmajor Mminor Vminor
Roof Live Load 83.35 0.04 -0.10 0.00 0.00

39 Dead Load 583.42 -3.47 0.26 -0.01 0.00


Roof Live Load 45.24 -0.46 -0.01 -0.00 0.00

40 Dead Load 970.58 -23.56 3.50 -0.01 0.00


Roof Live Load 125.24 -3.62 0.52 -0.00 0.00

41 Dead Load 702.90 -4.33 0.25 0.01 -0.00


Roof Live Load 81.55 -0.76 -0.00 0.00 -0.00

42 Dead Load 545.44 -88.45 17.16 0.88 -2.17


Roof Live Load 38.57 -11.63 1.68 0.03 -0.07

43 Dead Load 641.10 -194.92 37.40 -0.26 0.62


Roof Live Load 77.88 -29.08 5.47 -0.02 0.04

44 Dead Load 652.98 -112.20 20.91 -0.92 2.22


Roof Live Load 70.78 -19.26 2.89 -0.06 0.11

45 Dead Load 247.85 21.35 -12.01 0.40 -1.24


Roof Live Load 20.78 3.33 -1.77 0.12 -0.40

46 Dead Load 65.30 -0.27 2.17 0.46 -1.28


Roof Live Load 3.87 -0.06 0.34 0.08 -0.22

47 Dead Load 104.00 1.78 8.78 0.18 -0.48


Roof Live Load 9.79 0.19 1.11 0.01 -0.03

48 Dead Load 221.71 -36.55 2.73 1.19 -3.26


Roof Live Load 8.28 -3.99 0.67 0.08 -0.23

49 Dead Load 128.42 1.20 -1.09 0.00 -0.00


Roof Live Load 2.79 0.23 -0.22 -0.00 0.00

50 Dead Load 123.10 5.93 -0.39 0.86 -2.51


Roof Live Load 4.90 0.65 -0.44 0.06 -0.18

51 Dead Load 234.39 -43.73 7.92 1.87 -4.91


Roof Live Load 16.07 -6.24 1.58 0.19 -0.50

52 Dead Load 320.98 78.34 -3.53 1.50 -4.16


Roof Live Load 19.60 12.86 -1.10 0.15 -0.45

C31
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Section Cut ID: SC1H:1 (Horizontal)


Story: STEM
Ag = 167125 cm2 Imaj = 116007774436 Imin = 67277296862 cm4
cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:1E SC1H:1F SC1H:1G SC1H:1H SC1H:1I

SC1H:1D

SC1H:1C

SC1H:1B

SC1H:1A

SC1H:1J

Min

SC1H:1K
SC1H:1L SC1H:1M SC1H:1N SC1H:1O SC1H:1P
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.024 OK
Pu = 6428.25 kN phiPn = 266285.22 kN
Mu = 8061.9 kNm at Beta = -41.1 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:1A:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 36.7 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E20 (LC 94)
Code Ref: 11.5.4.5

Segment SC1H:1B:
Length = 3.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 151.5 kN phiVnC32
= 2319.5 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:1C:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 47.8 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:1D:
Length = 5.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 183.4 kN phiVn = 3615.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:1E:
Length = 5.65 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 125.3 kN phiVn = 3854.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:1F:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 102.3 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:1G:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 110.6 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:1H:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 123.7 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5
C33
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 3/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Segment SC1H:1I:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 130.0 kN phiVn = 2473.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:1J:
Length = 2.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 114.9 kN phiVn = 1978.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:1K:
Length = 2.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 81.0 kN phiVn = 1569.1 kN OK
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:1L:
Length = 5.65 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 178.3 kN phiVn = 3854.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:1M:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 139.5 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:1N:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 147.2 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:1O:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
C34
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 4/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Vu = 147.6 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:1P:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 148.9 kN phiVn = 2473.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.075% (11.6.2) OK
Segment SC1H:1A:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1C:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1F:
Max Vert Bar Spacing Limit: 457 mm Actual: C35150 mm (11.7.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 5/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1H:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
C36
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 6/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Segment SC1H:1N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:1P:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

C37
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 7/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Section Cut ID: SC1H:2 (Horizontal)


Story: STEM
Ag = 246375 cm2 Imaj = 369415847348 Imin = 211836623634
cm4 cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:2T SC1H:2S SC1H:2R SC1H:2Q SC1H:2P SC1H:2O

SC1H:2N

SC1H:2M
SC1H:2C
SC1H:2B
SC1H:2A
SC1H:2D

SC1H:2E
Min SC1H:2U

SC1H:2F
SC1H:2L SC1H:2K SC1H:2J SC1H:2I SC1H:2H SC1H:2G
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.034 OK
Pu = 13161.16 kN phiPn = 392134.94 kN
Mu = 17643.7 kNm at Beta = -53.2 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:2A:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 44.3 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:2B:
Length = 2.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 171.5 kN phiVnC38
= 1978.4 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 8/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:2C:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 85.2 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:2D:
Length = 2.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 111.7 kN phiVn = 1569.1 kN OK
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:2E:
Length = 2.80 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 130.5 kN phiVn = 1910.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E11 (LC 85)
Code Ref: 11.5.4.5

Segment SC1H:2F:
Length = 4.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 178.5 kN phiVn = 2728.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:2G:
Length = 6.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 190.4 kN phiVn = 4093.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:2H:
Length = 5.60 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 106.5 kN phiVn = 3820.3 kN OK
Controlling Load Combo: 1.200 D + 1.000 E30 (LC 104)
Code Ref: 11.5.4.5
C39
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 9/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Segment SC1H:2I:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 105.1 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:2J:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 105.9 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:2K:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 114.2 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:2L:
Length = 5.82 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 193.4 kN phiVn = 3973.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E31 (LC 105)
Code Ref: 11.5.4.5

Segment SC1H:2M:
Length = 3.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 166.9 kN phiVn = 2319.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Segment SC1H:2N:
Length = 5.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 225.1 kN phiVn = 3615.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:2O:
Length = 6.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
C40
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 10/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Vu = 213.9 kN phiVn = 4093.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:2P:
Length = 5.60 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 112.7 kN phiVn = 3820.3 kN OK
Controlling Load Combo: 1.200 D + 1.000 E13 (LC 87)
Code Ref: 11.5.4.5

Segment SC1H:2Q:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 117.9 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:2R:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 118.8 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:2S:
Length = 5.70 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 126.7 kN phiVn = 3888.5 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:2T:
Length = 5.82 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 210.6 kN phiVn = 3973.8 kN OK
Controlling Load Combo: 1.200 D + 1.000 E16 (LC 90)
Code Ref: 11.5.4.5

Segment SC1H:2U:
Length = 6.80 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 333.2 kN phiVn = 4639.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5
C41
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 11/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.068% (11.6.2) OK
Segment SC1H:2A:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2C:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2F:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2H:
Max Vert Bar Spacing Limit: 457 mm Actual: C42150 mm (11.7.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 12/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
C43
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 13/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Segment SC1H:2P:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2Q:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2R:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2S:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2T:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:2U:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

C44
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 14/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Section Cut ID: SC1H:3 (Horizontal)


Story: STEM
Ag = 167125 cm2 Imaj = 116007774436 Imin = 67277296862 cm4
cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:3E SC1H:3F SC1H:3G SC1H:3H SC1H:3I

SC1H:3D

SC1H:3C

SC1H:3B

SC1H:3A

SC1H:3J

Min

SC1H:3K
SC1H:3L SC1H:3M SC1H:3N SC1H:3O SC1H:3P
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.024 OK
Pu = 6423.37 kN phiPn = 266285.22 kN
Mu = 8266.2 kNm at Beta = -40.1 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:3A:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 36.7 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E20 (LC 94)
Code Ref: 11.5.4.5

Segment SC1H:3B:
Length = 3.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 151.5 kN phiVnC45
= 2319.5 kN OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 15/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.200 D + 1.000 E34 (LC 108)
Code Ref: 11.5.4.5

Segment SC1H:3C:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 44.4 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:3D:
Length = 5.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 183.4 kN phiVn = 3615.7 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:3E:
Length = 5.65 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 117.6 kN phiVn = 3854.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E7 (LC 81)
Code Ref: 11.5.4.5

Segment SC1H:3F:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 103.4 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:3G:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 110.6 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E6 (LC 80)
Code Ref: 11.5.4.5

Segment SC1H:3H:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 121.4 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5
C46
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 16/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Segment SC1H:3I:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 124.8 kN phiVn = 2473.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:3J:
Length = 2.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 111.5 kN phiVn = 1978.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:3K:
Length = 2.30 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 76.9 kN phiVn = 1569.1 kN OK
Controlling Load Combo: 1.200 D + 1.000 E35 (LC 109)
Code Ref: 11.5.4.5

Segment SC1H:3L:
Length = 5.65 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 168.9 kN phiVn = 3854.4 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:3M:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 138.7 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:3N:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 146.8 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E24 (LC 98)
Code Ref: 11.5.4.5

Segment SC1H:3O:
Length = 5.40 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
C47
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 17/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Shear Results:
Vu = 147.1 kN phiVn = 3683.9 kN OK
Controlling Load Combo: 1.200 D + 1.000 E21 (LC 95)
Code Ref: 11.5.4.5

Segment SC1H:3P:
Length = 3.62 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 140.3 kN phiVn = 2473.0 kN OK
Controlling Load Combo: 1.200 D + 1.000 E25 (LC 99)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 1.075% (11.6.2) OK
Segment SC1H:3A:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3B:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3C:
Max Vert Bar Spacing Limit: 333 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3D:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3E:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3F:
Max Vert Bar Spacing Limit: 457 mm Actual: C48150 mm (11.7.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 18/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3G:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3H:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3I:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3J:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3K:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3L:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3M:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
C49
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 19/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14
Segment SC1H:3N:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3O:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:3P:
Max Vert Bar Spacing Limit: 457 mm Actual: 150 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 134 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 1.056% Actual: 1.056% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

C50
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 20/382
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Section Cut ID: SC1H:4 (Horizontal)


Story: STEM
Ag = 246375 cm2 Imaj = 369415847348 Imin = 211836623634
cm4 cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:4T SC1H:4S SC1H:4R SC1H:4Q SC1H:4P SC1H:4O

SC1H:4N

SC1H:4M
SC1H:4C
SC1H:4B
SC1H:4A
SC1H:4D

SC1H:4E
Min SC1H:4U

SC1H:4F
SC1H:4L SC1H:4K SC1H:4J SC1H:4I SC1H:4H SC1H:4G
Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.034 OK
Pu = 13138.05 kN phiPn = 392134.94 kN
Mu = 17976.1 kNm at Beta = -51.8 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:4A:
Length = 1.00 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 44.3 kN phiVn = 682.2 kN OK
Controlling Load Combo: 1.200 D + 1.000 E10 (LC 84)
Code Ref: 11.5.4.5

Segment SC1H:4B:
Length = 2.90 m Thick = 250 mm f'c = 30.0 N/mm2 fy = 500.0 N/mm2
Vert Bar Pat: #5@150 mm oc Horiz Bar Pat: #5@150 mm oc
Vu = 171.5 kN phiVnC51
= 1978.4 kN OK
Wall Panel Reinforcing
RAM Concrete Shearwall 16.00.00.28
Database: Company Headquarters 05/07/19 13:46:57
Design Code: ACI 318-14

Wall Design Group: 1


Bar Pattern Template: 250mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 150 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
151 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
152 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
153 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
154 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
155 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
156 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
157 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
158 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
159 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
160 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
161 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
162 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
163 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%
164 (2) #5@150 mm oc 1.06% (2) #5@150 mm oc 1.06%

Wall Design Group: 2


Bar Pattern Template: 200mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 148 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%
149 (1) #5@300 mm oc 0.33% (1) #5@300 mm oc 0.33%

Wall Design Group: 3


Bar Pattern Template: 150mm WALL TEMPLATE

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
STEM 113 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%
114 (1) #5@300 mm oc 0.44% (1) #5@300 mm oc 0.44%

C52
Spread Footing Design Summary
RAM Foundation v16.00.00.28
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

Orientation Dimensions (m) f'c/fy Bottom Reinforcement Top Reinforcement


Grid Col/Foot Length Width Thick N/mm2 Parallel to Parallel to Parallel to Parallel to
Length Width Length Width
(17.73 - 4.00) 90.00/90.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
(24.92 - 4.00) 90.00/90.00 2.10 2.10 0.50 35.00/460.00 6-#6 6-#6 None None
* - Number between () in reinforcement is quantity of bars in center strip of rectangular footing

C53
Continuous Foundation Design
RAM Foundation v16.00.00.28
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 2
Length (m): 6.10
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.60 H/S 7-#6
2 1.60/ 4.20 S/S 7-#6
3 4.20/ 6.10 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 2.75 H/S 7-#6
2 2.75/ 6.10 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/ 2.75 8-#6 8-#6
3 2.75/ 5.95 None 10-#6
4 5.95/ 6.10 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 6.80) to (0.00, 9.10) 1.60 2300.00x250.01 Wall 0.00
(0.00, 9.10) to (0.00, 12.00) 4.20 2899.99x250.01 Wall 0.00
C54
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 2/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 16.95 145 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 24.27 149 2.75 74.82 145 0.15
Provided Pos. Moment (kNm) 335.06 2.75 365.23 0.15
Req. Max Neg. Moment (kNm) -2.31 318 0.45 -12.82 296 0.15
Provided Neg. Moment (kNm) -355.95 0.45 -389.11 0.15
Req. Max Punching Shear (kN) 335.51 145 1.60
Provided Punching Shear (kN) 2974.01 1.60
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 59.0 Ld Co # 509
Max Average Unfactored Soil Bearing (kN/m2) 46.5

C55
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 3/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 3
Length (m): 1.90
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 420.62
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 395.22
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 439.67 Bottom Bar Depth (mm) 414.27
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/ 1.75 5-#6 5-#6
3 1.75/ 1.90 1-#6 1-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.05 Not Applic. None
2 1.85/ 1.90 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

C56
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 4/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 12.00) to (1.00, 12.00) 0.95 1000.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 12.61 142 1.85
Provided Shear (kN) 640.67 1.85
Req. Max Pos. Moment (kNm) 8.89 142 1.45 24.91 1 0.15
Provided Pos. Moment (kNm) 339.46 1.45 239.40 0.15
Req. Max Neg. Moment (kNm) -2.20 313 1.45 -7.89 310 0.15
Provided Neg. Moment (kNm) -361.66 1.45 -254.33 0.15
Req. Max Punching Shear (kN) 94.47 145 0.95
Provided Punching Shear (kN) 2373.59 0.95
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 43.9 Ld Co # 509
Max Average Unfactored Soil Bearing (kN/m2) 37.6

C57
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 5/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 7
Length (m): 4.30
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.15 H/S 7-#6
2 2.15/ 4.30 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.60 H/S 7-#6
2 1.60/ 2.70 S/S 7-#6
3 2.70/ 4.30 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 4.15 None 12-#6
3 4.15/ 4.30 1-#6 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(1.00, 12.00) to (1.00, 15.40) 2.15 3399.99x250.01 Wall 0.00
CONCRETE CAPACITY
C58
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 6/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.49 159 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 12.95 159 0.45 83.41 1 0.15
Provided Pos. Moment (kNm) 335.06 0.45 548.08 0.15
Req. Max Neg. Moment (kNm) -2.09 327 3.85 -0.93 311 4.15
Provided Neg. Moment (kNm) -355.95 3.85 -47.70 4.15
Req. Max Punching Shear (kN) 344.86 159 2.15
Provided Punching Shear (kN) 3575.45 2.15
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 54.9 Ld Co # 523
Max Average Unfactored Soil Bearing (kN/m2) 48.0

C59
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 7/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 5
Length (m): 26.38
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.25 H/S 7-#6
2 3.25/ 8.80 S/S 7-#6
3 8.80/14.20 S/S 7-#6
4 14.20/21.41 S/S 7-#6
5 21.41/26.38 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.10 H/S 7-#6
2 6.10/11.70 S/S 7-#6
3 11.70/17.60 S/S 7-#6
4 17.60/26.38 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 1.45 None 4-#6
3 1.45/ 6.10 None 14-#6
4 6.10/11.50 None 16-#6
5 11.50/16.90 None 16-#6
6 16.90/22.31 None 16-#6
7 22.31/26.21 None 12-#6
8 26.21/26.38 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required. C60
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 8/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 15.40) to (1.00, 15.40) 0.95 1000.00x250.01 Wall 0.00
(1.00, 15.40) to (5.65, 15.40) 3.78 4650.00x200.00 Wall 0.00
(5.65, 15.40) to (11.05, 15.40) 8.80 5399.99x200.00 Wall 0.00
(11.05, 15.40) to (16.45, 15.40) 14.20 5399.99x200.00 Wall 0.00
(16.45, 15.40) to (21.85, 15.40) 19.60 5399.99x200.00 Wall 0.00
(21.85, 15.40) to (25.47, 15.40) 24.11 3625.01x200.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 12.63 1 26.34
Provided Shear (kN) 0.00 26.34
Req. Max Pos. Moment (kNm) 68.80 168 6.10 206.73 1 11.50
Provided Pos. Moment (kNm) 335.06 6.10 730.93 11.50
Req. Max Neg. Moment (kNm) -23.45 300 6.10 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 6.10 -0.00 0.00
Req. Max Punching Shear (kN) 707.34 1 14.20
Provided Punching Shear (kN) 4619.63 14.20
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 60.2 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 51.5

C61
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 9/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 4
Length (m): 6.20
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.30 H/S 7-#6
2 2.30/ 3.90 S/S 7-#6
3 3.90/ 6.20 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 2.30 H/S 7-#6
2 2.30/ 3.90 S/S 7-#6
3 3.90/ 6.20 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.05 17-#6 17-#6
3 6.05/ 6.20 1-#6 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 15.40) to (0.00, 20.70) 3.10 5299.99x250.01 Wall 0.00

C62
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 10/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.96 160 6.16
Provided Shear (kN) 0.00 6.16
Req. Max Pos. Moment (kNm) 13.67 160 5.75 125.66 136 0.15
Provided Pos. Moment (kNm) 335.06 5.75 776.97 0.15
Req. Max Neg. Moment (kNm) -2.93 159 5.75 -29.09 303 0.15
Provided Neg. Moment (kNm) -355.95 5.75 -827.72 0.15
Req. Max Punching Shear (kN) 601.12 160 3.10
Provided Punching Shear (kN) 4663.97 3.10
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 55.6 Ld Co # 524
Max Average Unfactored Soil Bearing (kN/m2) 49.0

C63
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 11/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 6
Length (m): 61.10
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.25 H/S 7-#6
2 3.25/ 8.80 S/S 7-#6
3 8.80/14.20 S/S 7-#6
4 14.20/21.41 S/S 7-#6
5 21.41/29.06 S/S 7-#6
6 29.06/34.81 S/S 7-#6
7 34.81/40.51 S/S 7-#6
8 40.51/46.21 S/S 7-#6
9 46.21/51.86 S/S 7-#6
10 51.86/57.66 S/S 7-#6
11 57.66/61.10 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.30 H/S 7-#6
2 6.30/11.90 S/S 7-#6
3 11.90/17.60 S/S 7-#6
4 17.60/25.41 S/S 7-#6
5 25.41/31.76 S/S 7-#6
6 31.76/37.86 S/S 7-#6
7 37.86/43.36 S/S 7-#6
8 43.36/48.86 S/S 7-#6
9 48.86/54.66 S/S 7-#6
10 54.66/61.10 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment C64
Top Bars Bot. Bars
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 12/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.10 None 17-#6
3 6.10/11.50 None 16-#6
4 11.50/16.90 None 16-#6
5 16.90/22.31 None 16-#6
6 22.31/26.01 None 11-#6
7 26.01/31.96 None 17-#6
8 31.96/37.66 None 17-#6
9 37.66/43.36 None 17-#6
10 43.36/49.06 None 17-#6
11 49.06/54.66 None 16-#6
12 54.66/60.97 None 18-#6
13 60.97/61.10 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 20.70) to (5.65, 20.70) 3.28 5650.00x250.01 Wall 0.00
(5.65, 20.70) to (11.05, 20.70) 8.80 5399.99x250.01 Wall 0.00
(11.05, 20.70) to (16.45, 20.70) 14.20 5399.99x250.01 Wall 0.00
(16.45, 20.70) to (21.85, 20.70) 19.60 5399.99x250.01 Wall 0.00
(21.85, 20.70) to (25.47, 20.70) 24.11 3625.01x250.01 Wall 0.00
(25.68, 20.70) to (31.50, 20.70) 29.04 5825.01x250.01 Wall 0.00
(31.50, 20.70) to (37.20, 20.70) 34.80 5699.99x250.01 Wall 0.00
(37.20, 20.70) to (42.90, 20.70) 40.50 5699.99x250.01 Wall 0.00
(42.90, 20.70) to (48.60, 20.70) 46.20 5699.99x250.01 Wall 0.00
(48.60, 20.70) to (54.20, 20.70) 51.85 5599.99x250.01 Wall 0.00
(54.20, 20.70) to (60.20, 20.70) 57.65 5999.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 14.59 142 61.06
Provided Shear (kN) 0.00 61.06
Req. Max Pos. Moment (kNm) 117.73 135 6.10 265.75 1 43.36
Provided Pos. Moment (kNm) 335.06 6.10 776.53 43.36
Req. Max Neg. Moment (kNm) -228.21 160 16.90 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 16.90 -0.00 0.00
Req. Max Punching Shear (kN) 1006.84 1 40.50
Provided Punching Shear (kN) 4896.68 40.50
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) C65
120.0
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 13/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 77.7 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 59.9

C66
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 14/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 1
Length (m): 26.38
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.25 H/S 7-#6
2 3.25/ 8.80 S/S 7-#6
3 8.80/14.20 S/S 7-#6
4 14.20/21.41 S/S 7-#6
5 21.41/26.38 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.50 H/S 7-#6
2 6.50/11.90 S/S 7-#6
3 11.90/17.60 S/S 7-#6
4 17.60/26.38 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.10 None 17-#6
3 6.10/11.50 None 16-#6
4 11.50/16.90 None 16-#6
5 16.90/22.31 None 16-#6
6 22.31/26.21 None 12-#6
7 26.21/26.38 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
C67
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 15/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.00, 6.80) to (5.65, 6.80) 3.28 5650.00x250.01 Wall 0.00
(5.65, 6.80) to (11.05, 6.80) 8.80 5399.99x250.01 Wall 0.00
(11.05, 6.80) to (16.45, 6.80) 14.20 5399.99x250.01 Wall 0.00
(16.45, 6.80) to (21.85, 6.80) 19.60 5399.99x250.01 Wall 0.00
(21.85, 6.80) to (25.47, 6.80) 24.11 3625.01x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.77 159 26.34
Provided Shear (kN) 0.00 26.34
Req. Max Pos. Moment (kNm) 106.22 318 6.10 188.08 1 11.50
Provided Pos. Moment (kNm) 335.06 6.10 730.93 11.50
Req. Max Neg. Moment (kNm) -175.27 153 11.50 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 11.50 -0.00 0.00
Req. Max Punching Shear (kN) 749.12 153 3.28
Provided Punching Shear (kN) 4867.56 3.28
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 57.9 Ld Co # 523
Max Average Unfactored Soil Bearing (kN/m2) 54.2

C68
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 16/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 11
Length (m): 21.60
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.55º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/10.80 H/S 7-#6
2 10.80/21.60 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/21.60 H/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.05 None 17-#6
3 6.05/ 9.15 None 9-#6
4 9.15/14.35 None 15-#6
5 14.35/21.46 None 21-#6
6 21.46/21.60 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(25.68, -0.00) to (25.68, 6.80) 3.85 6800.01x250.01 Wall 0.55
(25.68, 6.80) to (25.68, 12.00) 9.85 5199.99x150.01 Wall 0.55
(25.47, 6.80) to (25.47, 15.40) 11.55
C69 8600.01x150.01 Wall 0.55
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 17/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(25.68, 12.00) to (25.68, 20.70) 16.80 8700.01x150.01 Wall 0.55
(25.47, 15.40) to (25.47, 20.70) 18.50 5299.99x150.01 Wall 0.55
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 8.30 160 21.57
Provided Shear (kN) 0.00 21.57
Req. Max Pos. Moment (kNm) 6.43 160 21.15 198.05 1 0.15
Provided Pos. Moment (kNm) 335.06 21.15 776.97 0.15
Req. Max Neg. Moment (kNm) -0.01 327 21.15 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 21.15 -0.00 0.00
Req. Max Punching Shear (kN) 828.01 145 17.75
Provided Punching Shear (kN) 5540.02 17.75
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 52.9 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 47.2

C70
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 18/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 12
Length (m): 35.43
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.35 H/S 7-#6
2 3.35/ 9.10 S/S 7-#6
3 9.10/14.80 S/S 7-#6
4 14.80/20.51 S/S 7-#6
5 20.51/26.16 S/S 7-#6
6 26.16/31.46 S/S 7-#6
7 31.46/34.46 S/S 7-#6
8 34.46/35.43 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.30 H/S 7-#6
2 6.30/12.15 S/S 7-#6
3 12.15/17.65 S/S 7-#6
4 17.65/23.16 S/S 7-#6
5 23.16/28.96 S/S 7-#6
6 28.96/33.01 S/S 7-#6
7 33.01/35.43 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.28 None 18-#6
3 6.28/11.98 None 17-#6
4 11.98/17.65 None 17-#6
5 17.65/23.36 C71
None 17-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 19/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
6 23.36/28.96 None 16-#6
7 28.96/33.96 None 15-#6
8 33.96/35.26 None 4-#6
9 35.26/35.43 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(25.68, 12.00) to (31.50, 12.00) 3.36 5825.01x150.01 Wall -0.00
(31.50, 12.00) to (37.20, 12.00) 9.13 5699.99x150.01 Wall 0.00
(37.20, 12.00) to (42.90, 12.00) 14.83 5699.99x150.01 Wall 0.00
(42.90, 12.00) to (48.60, 12.00) 20.53 5699.99x150.01 Wall 0.00
(48.60, 12.00) to (54.20, 12.00) 26.18 5599.99x150.01 Wall 0.00
(54.20, 12.00) to (59.20, 12.00) 31.48 4999.99x150.01 Wall 0.00
(59.20, 12.00) to (60.20, 12.00) 34.48 1000.00x250.01 Wall -0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 16.89 1 35.39
Provided Shear (kN) 0.00 35.39
Req. Max Pos. Moment (kNm) 90.35 138 6.28 390.22 1 11.98
Provided Pos. Moment (kNm) 335.06 6.28 776.47 11.98
Req. Max Neg. Moment (kNm) -179.51 1 17.68 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 17.68 -0.00 0.00
Req. Max Punching Shear (kN) 1412.87 18 14.83
Provided Punching Shear (kN) 4694.11 14.83
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 105.4 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 87.0

C72
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 20/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 16
Length (m): 9.60
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.15 H/S 7-#6
2 2.15/ 6.50 S/S 7-#6
3 6.50/ 9.60 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.05 H/S 7-#6
2 4.05/ 9.60 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 3.85 None 11-#6
3 3.85/ 9.45 None 16-#6
4 9.45/ 9.60 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(60.20, 12.00) to (60.20, 15.40) 2.15 3399.99x250.01 Wall 0.00
(60.20, 15.40) to (60.20, 20.70) 6.50 5299.99x250.01 Wall 0.00
C73
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 21/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 16.49 150 9.56
Provided Shear (kN) 0.00 9.56
Req. Max Pos. Moment (kNm) 15.38 136 3.85 157.66 150 3.85
Provided Pos. Moment (kNm) 335.06 3.85 731.37 3.85
Req. Max Neg. Moment (kNm) -15.08 303 3.85 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 3.85 -0.00 0.00
Req. Max Punching Shear (kN) 738.87 150 6.50
Provided Punching Shear (kN) 4663.97 6.50
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 58.7 Ld Co # 514
Max Average Unfactored Soil Bearing (kN/m2) 51.6

C74
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 22/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 15
Length (m): 10.00
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 2.45 H/S 7-#6
2 2.45/ 5.85 S/S 7-#6
3 5.85/ 8.40 S/S 7-#6
4 8.40/10.00 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 4.65 H/S 7-#6
2 4.65/ 6.85 S/S 7-#6
3 6.85/10.00 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 4.45 None 13-#6
3 4.45/ 7.25 None 8-#6
4 7.25/ 9.85 None 8-#6
5 9.85/10.00 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
C75
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 23/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(60.20, 0.00) to (60.20, 4.00) 2.45 3999.99x250.01 Wall 0.00
(60.20, 4.00) to (60.20, 6.80) 5.85 2799.99x250.01 Wall 0.00
(60.20, 6.80) to (60.20, 9.10) 8.40 2300.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.75 135 0.04
Provided Shear (kN) 0.00 0.04
Req. Max Pos. Moment (kNm) 40.11 153 7.25 117.91 135 0.15
Provided Pos. Moment (kNm) 335.06 7.25 593.68 0.15
Req. Max Neg. Moment (kNm) -11.46 318 7.25 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 7.25 -0.00 0.00
Req. Max Punching Shear (kN) 536.75 135 2.45
Provided Punching Shear (kN) 3915.02 2.45
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 55.5 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 44.9

C76
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 24/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 14
Length (m): 1.90
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 420.62
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 395.22
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 7-#6
2 0.70/ 1.20 S/S 7-#6
3 1.20/ 1.90 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 439.67 Bottom Bar Depth (mm) 414.27
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 1-#6 1-#6
2 0.15/ 1.75 5-#6 5-#6
3 1.75/ 1.90 None 1-#6

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.05 Not Applic. None
2 1.85/ 1.90 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
SUPPORTED MEMBERS

C77
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 25/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(59.20, 9.10) to (60.20, 9.10) 0.95 1000.00x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.85 135 1.85
Provided Shear (kN) 640.67 1.85
Req. Max Pos. Moment (kNm) 11.57 135 1.45 28.58 1 0.15
Provided Pos. Moment (kNm) 339.46 1.45 239.40 0.15
Req. Max Neg. Moment (kNm) -1.48 304 1.45 -7.89 303 0.15
Provided Neg. Moment (kNm) -361.66 1.45 -254.33 0.15
Req. Max Punching Shear (kN) 109.87 135 0.95
Provided Punching Shear (kN) 2373.59 0.95
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 50.1 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 42.3

C78
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 26/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 13
Length (m): 3.80
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.90 H/S 7-#6
2 1.90/ 3.80 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.40 H/S 7-#6
2 1.40/ 2.40 S/S 7-#6
3 2.40/ 3.80 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 420.62 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 3.65 None 10-#6
3 3.65/ 3.80 1-#6 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(59.20, 9.10) to (59.20, 12.00) 1.90 2899.99x250.01 Wall 0.00
CONCRETE CAPACITY
C79
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 27/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 16.11 136 3.76
Provided Shear (kN) 0.00 3.76
Req. Max Pos. Moment (kNm) 13.68 136 3.35 93.69 1 0.15
Provided Pos. Moment (kNm) 335.06 3.35 457.11 0.15
Req. Max Neg. Moment (kNm) -1.94 303 3.35 -0.94 303 3.65
Provided Neg. Moment (kNm) -355.95 3.35 -47.70 3.65
Req. Max Punching Shear (kN) 411.59 153 1.90
Provided Punching Shear (kN) 3297.56 1.90
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 71.4 Ld Co # 499
Max Average Unfactored Soil Bearing (kN/m2) 59.0

C80
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 28/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 10
Length (m): 35.43
Width (m): 2.20
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (N/mm2): 35.00 fct (N/mm2): CODE Density (kg/m3): 2349.99 Ec (N/mm2): 28804.56
Reinf. fy (N/mm2): 460.00
LOADS
Surcharge (kN/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.67
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 3.35 H/S 7-#6
2 3.35/ 9.10 S/S 7-#6
3 9.10/14.80 S/S 7-#6
4 14.80/20.51 S/S 7-#6
5 20.51/26.16 S/S 7-#6
6 26.16/31.96 S/S 7-#6
7 31.96/35.43 S/H 7-#6

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 414.27
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 6.25 H/S 7-#6
2 6.25/12.15 S/S 7-#6
3 12.15/17.65 S/S 7-#6
4 17.65/23.16 S/S 7-#6
5 23.16/28.96 S/S 7-#6
6 28.96/35.43 S/H 7-#6

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 430.15 Bottom Bar Depth (mm) 395.22
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#6
2 0.15/ 6.28 None 18-#6
3 6.28/11.98 None 17-#6
4 11.98/17.65 None 17-#6
5 17.65/23.36 None 17-#6
6 23.36/28.96 None 16-#6
7 28.96/35.26 C81
None 18-#6
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 29/29
DataBase: Company Headquarters Date: 05/07/19 14:01:55
Building Code: IBC Design Code: ACI318-14
Num. Start/End (m)
8 35.26/35.43 None 1-#6

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(25.68, -0.00) to (31.50, 0.00) 3.36 5825.01x250.01 Wall 0.00
(31.50, 0.00) to (37.20, 0.00) 9.13 5699.99x250.01 Wall 0.00
(37.20, 0.00) to (42.90, 0.00) 14.83 5699.99x250.01 Wall 0.00
(42.90, 0.00) to (48.60, 0.00) 20.53 5699.99x250.01 Wall 0.00
(48.60, 0.00) to (54.20, 0.00) 26.18 5599.99x250.01 Wall 0.00
(54.20, 0.00) to (60.20, 0.00) 31.98 5999.99x250.01 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kN) 15.45 159 35.39
Provided Shear (kN) 0.00 35.39
Req. Max Pos. Moment (kNm) 81.83 318 6.28 226.48 1 11.98
Provided Pos. Moment (kNm) 335.06 6.28 776.47 11.98
Req. Max Neg. Moment (kNm) -141.53 145 11.98 -0.00 -1 0.00
Provided Neg. Moment (kNm) -355.95 11.98 -0.00 0.00
Req. Max Punching Shear (kN) 852.52 159 31.98
Provided Punching Shear (kN) 5071.70 31.98
SOIL CAPACITY
Allowable Soil Bearing Capacity (kN/m2) 120.0
Soil Subgrade Modulus (kN/m2 / m) 9448.8
Max Unfactored Soil Bearing (kN/m2) 64.4 Ld Co # 368
Max Average Unfactored Soil Bearing (kN/m2) 60.7

C82
C83
C84
FOR CMU WALL DESIGN
SEE FIRE PUMP HOUSE (BUILDING E)

C85
C86
SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
D. Guard House

Building Design Page No.

RAM Calculation Check……………………………………………………………………………………… D1 - D2

RAM Back-Up Calculations…………………………………………………………………………….. D3 - D7

RAM Model………………………………………………………………………………………………… D8 - D 26

RAM Frame Analysis…………………………………………………………………………………….. D 27 - D 56

RAM Concrete Design…………………………………………………………………………………… D 57 - D 79

RAM Foundation Design……………………………………………………………………………….. D 80 - D 113

Slab on Grade Design……………………………...………………………………………………………… D 114 - D 114

Roof Slab Design……………………………...………………………………………………………………… D 115 - D 127

Parapet Design……………………………...…………………………………………………………………… D 128 - D 128


D1
D2
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\D - Guard House\RAM\
GH backup
Geometry

GUARD HOUSE
BUILDING GEOMETRY
Building Lengths
Ext Face of Wall to Ext Face of Wall
Overall (Out to Out) 2700 mm 2.70 m 8.86 ft <-- Ext Face of Columns Along Grids 1 to 2

CL to CL of Exterior Columns/Walls
Overall (CL to CL) 2300 mm 2.30 m 7.54 ft <-- CL to CL of Exterior Columns Along Grids 1' to 2'

Building Widths
Ext Face of Wall to Ext Face of Wall
Overall (Out to Out) 4650 mm 4.65 m 15.25 ft <-- Ext Face of Columns Along Grids A to C

CL to CL of Exterior Columns/Walls
Overall (CL to CL) 4250 mm 4.25 m 13.94 ft <-- CL to CL of Exterior Columns Along Grids A' to C'

Column Size
Length 400 mm 0.40 m 1.31 ft
Width 400 mm 0.40 m 1.31 ft

GRID GEOMETRY GUARD HOUSE


MAIN GRIDLINE LOCATIONS FOR RAM INPUT (SEE CALCULATION BELOW)

X-GRID ALONG X Y-GRID ALONG Y


X m Y m
1 0.0000 A 0.0000 1 Xi
1' 0.1000 A' 0.1000
2' 2.6000 B 0.9500
2 2.7000 C' 4.5500 Yi
C 4.6500
y
X
A 0,

CALCULATE GRIDLINE LOCATIONS

X-GRID to GRID CL TO CL X-GRID ALONG X ALONG X Y-GRID to GRID CL TO CL Y-GRID ALONG Y ALONG Y A-B 950 1-2 2700
0 0 mm m 0 0 mm m B-C 3700
1 1' 100 1 0 0.000 A A' 100 A 0 0.000
1' 2' 2500 1' 100 0.100 A' B 850 A' 100 0.100
2' 2 100 2' 2600 2.600 B C' 3600 B 950 0.950
2 2 2700 2.700 C' C 100 C' 4550 4.550
C C 4650 4.650

Length 2700 2.70 8.86 ft Width 4650 4.65 15.25 ft A-C 4650 1-2 2700
Max Span 2500 2.50 8.20 ft Max Span 3600 3.60 11.81 ft
Min Span 100 0.10 0.33 ft Min Span 100 0.10 0.33 ft

FLOOR TYPE & STORY LABELS GUARD HOUSE

Building Elevations

Top of Footing -1000 mm -1.00 m -3.28 ft Story Elevation/Story Height


Bottom of Column/Wall 0 mm 0.00 m 0.00 ft 1 3200
Top of Ground Slab 0 mm 0.00 m 0.00 ft
Bottom of Roof 3000 mm 3.00 m 9.84 ft
Top of Roof 3200 mm 3.20 m 10.50 ft

Top of Parapet 4000 mm 4.00 m 13.12 ft


Bottom of Parapet 2500 mm 2.50 m 8.20 ft

Parapet Height 1500 mm 1.50 m 4.92 ft

Ground Floor Slab Thickness 150 mm 0.15 m 0.49 ft


Roof Slab Thickness 200 mm 0.20 m 0.66 ft

EL of Floor Type (Layout) Story


Level Story Label Level Description Height
Floor Type ID
(mm) (m)
1 T.O. Roof 3200 Top of Roof Slab Ground Floor 3.20

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
D3 Page 1 of 1
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\D - Guard House\RAM\
GH backup
LOADS

GENERAL INFORMATION GUARD HOUSE

Job = Royal Saudi Land Force (RSLF), Artillery Brigade


Building = Guard House

Codes : ACI 318-14


IBC 2015
ASCE 7-10
UFC 3-301-01, Sept. 2016

Country : KSA
Base / City : Eastern Province

Risk Category : IV UFC 3-301-01 Table 2-2


IV

Importance Factors
Iw = 1.00 UFC 3-301-01 Table 2-2
Is = 1.20 UFC 3-301-01 Table 2-2
Ie = 1.50 UFC 3-301-01 Table 2-2

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
D4 Page 1 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\D - Guard House\RAM\
GH backup
LOADS

LOADS GUARD HOUSE

DEAD LOADS

Roofing Dead Load

Building Width = 6486 mm


Cricket Width = 1972 mm

Roof is single pitched


unique roof areas = 4
area width = 1621.50 mm

rise run
roof slope = 42 1000

ROOFING MATERIAL
Cellular Concrete Unit Weight = 50 pcf 800.92 kg/cu_m
Insulation & Concrete Pavers = 20 psf 97.65 kg/sq_m

AREA
1 2 3 4
distance from center of area to edge of roof (mm) = 810.75 2432.25 4053.75 5675.25
avg. roof thickness in area (mm) = 82.82 103.75 170.26 238.36
Cellular Concrete Load (kg/sq_m) = 66.34 83.09 136.36 190.91
Insulation & Paver Load (kg/sq_m) = 97.65 97.65 97.65 97.65
Total (kg/sq_m) = 163.98 180.74 234.01 288.56
Say --> 165 185 235 290

Dead Load due to Exterior Walls

Wall Type : Concrete

Concrete Weight = 150 pcf 2403 kg/cu_m


Wall Thickness = 8 in 200 mm
Parapet Height = 4.92 ft 1500 mm

Line Load Type Height Load Height Load Say Mass Dead Load
h (m) ft plf m kg/m kg/m Location % kg/m
Concrete (Roof) h =3.2 10.50 1050 3.20 1538 1540 Roof 0% 0
Concrete (Stem Wall) h =3.2 10.50 1050 3.20 1538 1540 Stem Wall 0% 0
Concrete (Parapet) h =1.5 4.92 492 1.50 721 730 Parapet 100% 730

Wall Type : CMU Veneer

CMU Veneer Weight = 45 psf 220 kg/sq_m


Veneer Thickness = 4 in 100 mm
Ground Floor Wall Height = 10.50 ft 3200 mm
Parapet Height = 4.92 ft 1500 mm

Line Load Type Height Load Height Load Say Mass Dead Load
h (m) ft plf m kg/m kg/m Location % kg/m
CMU Veneer (Roof) h =3.2 10.50 472 3.20 703 710 Roof 50% 355
CMU Veneer (Stem Wall) h =3.2 10.50 472 3.20 703 710 Stem Wall 50% 355
CMU Veneer (Parapet) h =1.5 4.92 221 1.50 330 330 Parapet 0% 0

Collateral Dead Load

DLCL = 10 psf 50 kg/sq_m

HVAC (Minor)

DLHVAC = 10 psf 50 kg/sq_m

LIVE LOADS

Roof Live Load

Min. Roof LL = 20 psf 97.65 kg/sq_m 957.6 Pa UFC 3-301-01 Table D-1
Given Roof Live Load = 20.89 psf 101.97 kg/sq_m 1000 Pa

Governing Roof LL = 101.97 kg/sq_m Say --> 102 kg/sq_m

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
D5 Page 2 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\D - Guard House\RAM\
GH backup
LOADS

SURFACE LOAD SUMMARY

TOTAL
DLCL DLHVAC DLRoofing LLRoof
LOAD DL LL MDL
kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m
Roof -Area 1 50 50 165 102 265 102 265
Roof -Area 2 50 50 185 102 285 102 285
Roof -Area 3 50 50 235 102 335 102 335
Roof -Area 4 50 50 290 102 390 102 390

LINE LOAD SUMMARY

TOTAL
DLParapet DLVeneer DLWall
LOAD DL MDL
kg/m kg/m kg/m kg/m kg/m
DL: Parapet 730 0 0 730 730
DL: Veneer @ Roof 0 355 0 0 355
DL: Veneer @ Stem Wall 0 355 0 710 355

SNOW LOAD

Importance Factor, Is = 1.20


Ground Snow = 0 psf 0 kPa UFC 3-301-01 Table F-1
Frost Pentration = 0 in 0 mm

WIND LOADS

Importance Factor, Iw = 1.00 Wind Speed, V = 115 mph 185 km/hr UFC 3-301-01 Table F-1
Exposure : C Directionality Factor, Kd = 0.85 ASCE 7-10 Table 26.6-1
Risk Category : IV Topographic Factor, Kzt = 1 ASCE 7-10 26.8.2
Velocity Pressure Exposure Coefficient Kh = 0.850 ASCE 7-10 Table 27.3-1
2
qz = 0.00256KzKztKdV = 24.44 psf 119.33 kg/sq_m ASCE 7-10 27.3.2

Parapet Height = 0.800 m <-- Added to Exposure in RAM

SEISMIC LOADS

Importance Factor, Ie = 1.50


Risk Category : IV
Site Class : D IBC 2012 1613.3.2
Peak Ground Acceleration, PGA = 14% g UFC 3-301-01 Table F-3
Ss = 37% g
S1 = 17% g

Seismic Design Category, SDC : D ASCE 7-10


Seismic Force Resisting System : SPECIAL REINFORCED CONCRETE SHEAR WALLS ASCE 7-10 Table 12.2-1
g
Height Limit : NO LIMIT Overstrength Factor, Ω0 = 2.5
Response Modification Coeff., Ra = 5 Deflection Amplification Factor, Cdb = 5

T0 = 0.2SD1/SDS = 0.130 SDS = 0.371 g Ct = 0.0488 ASCE 7-10 Table 12.8-2


TS = SD1/SDS = 0.648 SD1 = 0.240 g x= 0.75
hn = 3.20 m
x
Approx. Fundamental Period, Ta = Cthn
Ta = 0.117 sec Total Building Weight, W = 58,758 kg <-- VALUE TAKEN FROM RAM
Fundamental Period, T = Ta Seismic Response Coefficient, Cs = 0.111 =SDS/(R/Ie)
Seismic Base Shear, V = CsW = 6,540 kg ASCE 7-10 Equation 12.8-1

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
D6 Page 3 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\D - Guard House\RAM\
GH backup
Seismic Calcs

SEISMIC DESIGN PARAMETERS GUARD HOUSE

PGA = 0.14 g
(0.2s) Ss = 0.37 g
(0.1s) S1 = 0.17 g
Site Class : D

ASCE 7-10 TABLE 11.8-1


SITE COEFFICIENT, FPGA
SITE PEAK GROUND ACCELERATION COEFFICIENT
CLASS PGA ≤ 0.1 PGA = 0.2 PGA = 0.3 PGA = 0.4 PGA ≥ 0.5
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7

FPGA = 1.52
PGAM = FPGAPGA = 0.2128

ASCE 7-10 TABLE 11.4-1


SITE COEFFICIENT, FA
SITE MCER AT SHORT PERIOD
CLASS SS ≤ 0.25 SS = 0.5 SS = 0.75 SS = 1.0 SS ≥ 1.25
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7

FA = 1.504 Seismic Design Category : D


SMS = FASS = 0.55648 SDS = (2/3)SMS = 0.371

ASCE 7-10 TABLE 11.4-2


SITE COEFFICIENT, FV
SITE MCER AT 1-s PERIOD
CLASS S1 ≤ 0.1 S1 = 0.2 S1 = 0.3 S1 = 0.4 S1 ≥ 0.5
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.7 1.6 1.5 1.4 1.3
D 2.4 2.0 1.8 1.6 1.5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7

FV = 2.12 Seismic Design Category : D


SM1 = FVS1 = 0.3604 SD1 = (2/3)SM1 = 0.240

SUMMARY
PGAM = 0.2128
SDS = 0.3710 SDC : D
SD1 = 0.2403 SDC : D

Governing SDC : D

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
D7 Page 1 of 1
General Criteria
RAM Structural System 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC

BUILDING CODE FOR LIVE LOAD REDUCTION: IBC


Live Load Reduction Method: General

ROOF LOADS:
Consider Roof Live Loads, Ignore Snow Loads
Roof Live Loads are Reducible

DETERMINING NUMBER OF STORIES FOR LIVE LOAD REDUCTION:


Include Roof Levels: No
Include Unreducible Levels: Yes
Include Storage Levels: Yes

SELF-WEIGHT:
Automatically calculate and include Self-Weight for Member Dead Loads:
Beams: Yes
Columns: Yes
Walls: Yes
Slabs / Decks: Yes

Automatically calculate and include Self-Weight for Story Masses:


Beams: Yes
Columns: Yes
Include half mass of columns above and below
Walls: Yes
Include half mass of walls above and below
Slabs / Decks: Yes

D8
Echo of Input Data
RAM Structural System 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC

Layout Types:
Roof
Top of stem wall
Tables Selected:
Deck Table: ramdecks
Master Steel Table: ramaisc
Default Steel Table: ramaisc
Alternate Steel Table: ramaisc
Column Steel Table: ramaisc
Reinforcement Table: ramgb50010
Pan Form Table: RamCECO
Story Data:
Level Story Label Layout Type Height (m)
2 TO ROOF Roof 3.200
1 TO STEM WALL Top of stem wall 1.000

Concrete Floor Properties:


ID Label Effect Thick f'c Unit Wt UW-Self Poisson's Bending Fac Diaph Fac
mm kg/cm2 kg/m3 kg/m3
1 200 Slab 200.00 281.23 2322.68 2402.77 0.20 1.00 1.00

ID Angle f11 f22 f12 m11 m22 m12


1 --- --- --- --- --- --- ---

Load Properties:
Surface:
ID DL Constr DL LL Reduct. Partition Constr LL Mass DL
kg/m2 kg/m2 kg/m2 Type kg/m2 kg/m2 kg/m2
R-A1 265.0 50.0 102.0 Roof 0.0 0.0 265.0
R-A2 285.0 50.0 102.0 Roof 0.0 0.0 285.0
R-A3 335.0 50.0 102.0 Roof 0.0 0.0 335.0
R-A4 390.0 50.0 102.0 Roof 0.0 0.0 390.0

Line:
ID DL Constr DL LL Reduct. Partition Constr LL Mass DL
kg/m kg/m kg/m Type kg/m kg/m kg/m
DL: Parapet 730.000 0.000 0.000 Unred. 0.000 0.000 730.000
DL: Veneer @ 0.000 0.000 0.000 Unred. 0.000 0.000 355.000
Roof
DL: 710.000 0.000 0.000 Unred. 0.000 0.000 355.000
Veneer@Stem
Wall
D9
Echo of Input Data
RAM Structural System 16.00.00.28 Page 2/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC

COLUMN SECTION PROPERTIES:


Concrete:
# Label Shape Depth/Diam Width Cracked Factor
mm mm Axial Flex Tors
1 400X400 Rect 400.00 400.00 1.00 0.70 1.00
Grid Systems:
System Label Type X Offset Y Offset Rotation
m m
MAIN Orthogonal 0.000 0.000 0.00
WALL CL Orthogonal 0.000 0.000 0.00
ROOF EDGE Orthogonal 0.000 0.000 0.00
LIMITS Orthogonal 0.000 0.000 0.00
Grids:
System: MAIN
X Grids Label X Min Y Max Y
m m m
1 0.0000 -0.5000 5.1500
1.1 0.7000 -0.5000 5.1500
1.2 2.0000 -0.5000 5.1500
2 2.7000 -0.5000 5.1500

Y Grids Label Y Min X Max X


m m m
A 0.0000 ---- ----
B 0.9500 ---- ----
C 4.6500 ---- ----

System: WALL CL
X Grids Label X Min Y Max Y
m m m
1' 0.1000 ---- ----
2' 2.6000 ---- ----

Y Grids Label Y Min X Max X


m m m
A' 0.1000 -0.5000 3.2000
B1 0.7500 -0.5000 3.2000
B 0.9500 -0.5000 3.2000
B2 1.1500 -0.5000 3.2000
C' 4.5500 -0.5000 3.2000

System: ROOF EDGE

D10
Echo of Input Data
RAM Structural System 16.00.00.28 Page 3/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC
X Grids Label X Min Y Max Y
m m m
1R1 -1.5470 ---- ----
1R2 -0.8560 ---- ----
1R3 -0.7430 ---- ----
2R1 3.4430 ---- ----
2R2 3.5610 ---- ----
2R3 4.2470 ---- ----

Y Grids Label Y Min X Max X


m m m
AR2' -1.0750 ---- ----
AR1' -0.3890 ---- ----
AC4 0.5465 ---- ----
AC3 2.1680 ---- ----
CR2 2.8110 ---- ----
AC2 3.7895 ---- ----
CR1 5.4110 ---- ----

System: LIMITS
X Grids Label X Min Y Max Y
m m m
01 -3.0000 ---- ----
02 8.0000 ---- ----

Y Grids Label Y Min X Max X


m m m
0A -3.0000 ---- ----
0C 6.0000 ---- ----

DATA FOR FLOOR TYPE: Roof


Grid Systems:
MAIN
WALL CL
ROOF EDGE
Columns:
ID X Y Shape Orientation Param* LLRed Frame
m m Angle kg/cm2 % Type
1 0.100 0.950 Conc 0.00 281.2 Calc Gravity
2 2.600 0.950 Conc 0.00 281.2 Calc Gravity

* Parameter: Steel - Fy
Concrete - f'c
Other - E D11
Echo of Input Data
RAM Structural System 16.00.00.28 Page 4/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC

Concrete Column Properties:


ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
(kg/m3) (kg/m3) Type (kg/cm2) (kg/cm2) Ratio (kg/cm2) (kg/cm2)
1 2322.68 2402.77 NWC ---- Code 0.20 4218.40 4218.40
2 2322.68 2402.77 NWC ---- Code 0.20 4218.40 4218.40
Walls:
ID Xi Yi Xj Yj Frame Material LLRed
m m m m Type %
1 0.100 0.950 0.100 4.550 Lateral Concrete Calc
2 0.100 0.950 0.700 0.100 Gravity Concrete Calc
3 0.100 4.550 2.600 4.550 Lateral Concrete Calc
4 0.700 0.100 2.000 0.100 Gravity Concrete Calc
5 2.000 0.100 2.600 0.950 Gravity Concrete Calc
6 2.600 0.950 2.600 4.550 Lateral Concrete Calc
Concrete Wall Properties:
ID Pois UnitWt UW Self f'c Thick Ec
kg/m3 kg/m3 kg/cm2 mm kg/cm2
1 0.20 2322.68 2402.770 281.230 200.000 Calc
0
2 0.20 2322.68 2402.770 281.230 200.000 Calc
0
3 0.20 2322.68 2402.770 281.230 200.000 Calc
0
4 0.20 2322.68 2402.770 281.230 200.000 Calc
0
5 0.20 2322.68 2402.770 281.230 200.000 Calc
0
6 0.20 2322.68 2402.770 281.230 200.000 Calc
0

Wall Openings:
Wall # Opening # Reference Corner X Y Width Height
m m m m
1 1 Lower Right 2.000 0.000 1.521 2.200
3 1 Lower Left 1.703 1.800 0.600 0.400
6 1 Lower Right 2.000 0.000 1.521 2.200

Slab Edges:
Xi Yi Xj Yj Edge Dist
m m m m mm
Diaphragm 1:
-0.743 2.811 -0.743 5.411 0.0
D12
Echo of Input Data
RAM Structural System 16.00.00.28 Page 5/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC
Xi Yi Xj Yj Edge Dist
-0.743 5.411 3.443 5.411 0.0
3.443 2.811 3.443 5.411 0.0
3.443 2.811 4.247 2.811 0.0
4.247 -0.389 4.247 2.811 0.0
3.561 -1.075 4.247 -0.389 0.0
-0.856 -1.075 3.561 -1.075 0.0
-1.547 -0.389 -0.856 -1.075 0.0
-1.547 -0.389 -1.547 2.811 0.0
-1.547 2.811 -0.743 2.811 0.0
Deck Polygons:
Deck Prop Slab Action Angle X-Coord Y-Coord
Type ID m m
Concrete 1 One-Way 0.00 -3.09 7.09
5.79 7.09
5.79 -2.49
-3.09 -2.49
-3.09 7.09
Load Polygons:
Load Properties ID X-Coord Y-Coord
m m
R-A1 -0.74 5.41
-0.74 3.79
3.44 3.79
3.44 5.41
-0.74 5.41
R-A2 -0.74 3.79
-0.74 2.81
-1.55 2.81
-1.55 2.17
4.25 2.17
4.25 2.81
3.44 2.81
3.44 3.79
-0.74 3.79
R-A3 -1.55 2.17
-1.55 0.55
4.25 0.55
4.25 2.17
-1.55 2.17
R-A4 -1.55 0.55
-1.55 -0.39
-0.86 -1.07
3.56 -1.07
D13
Echo of Input Data
RAM Structural System 16.00.00.28 Page 6/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC
Load Properties ID X-Coord Y-Coord
4.25 -0.39
4.25 0.55
-1.55 0.55
User Input Line Loads:
Load Properties ID Xi Yi Xj Yj
m m m m
DL: Veneer @ Roof 0.10 4.55 2.60 4.55
DL: Veneer @ Roof 0.10 0.95 0.10 4.55
DL: Veneer @ Roof 0.10 0.95 0.70 0.10
DL: Veneer @ Roof 0.70 0.10 2.00 0.10
DL: Veneer @ Roof 2.00 0.10 2.60 0.95
DL: Veneer @ Roof 2.60 0.95 2.60 4.55
DL: Parapet -0.74 5.41 3.44 5.41
DL: Parapet -0.74 2.81 -0.74 5.41
DL: Parapet -1.55 2.81 -0.74 2.81
DL: Parapet -1.55 -0.39 -1.55 2.81
DL: Parapet -1.55 -0.39 -0.86 -1.07
DL: Parapet -0.86 -1.07 3.56 -1.07
DL: Parapet 3.56 -1.07 4.25 -0.39
DL: Parapet 4.25 -0.39 4.25 2.81
DL: Parapet 3.44 2.81 4.25 2.81
DL: Parapet 3.44 2.81 3.44 5.41

DATA FOR FLOOR TYPE: Top of stem wall


Grid Systems:
MAIN
WALL CL
Columns:
ID X Y Shape Orientation Param* LLRed Frame
m m Angle kg/cm2 % Type
1 0.100 0.950 Conc 0.00 281.2 Calc Gravity
2 2.600 0.950 Conc 0.00 281.2 Calc Gravity

* Parameter: Steel - Fy
Concrete - f'c
Other - E

Concrete Column Properties:


ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
(kg/m3) (kg/m3) Type (kg/cm2) (kg/cm2) Ratio (kg/cm2) (kg/cm2)
1 2322.68 2402.77 NWC ---- Code 0.20 4218.40 4218.40
2 2322.68 2402.77 NWC ---- D14 Code 0.20 4218.40 4218.40
Echo of Input Data
RAM Structural System 16.00.00.28 Page 7/7
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51
Building Code: IBC

Walls:
ID Xi Yi Xj Yj Frame Material LLRed
m m m m Type %
1 0.100 0.950 0.100 4.550 Lateral Concrete Calc
2 0.100 0.950 0.700 0.100 Gravity Concrete Calc
3 0.100 4.550 2.600 4.550 Lateral Concrete Calc
4 0.700 0.100 2.000 0.100 Gravity Concrete Calc
5 2.000 0.100 2.600 0.950 Gravity Concrete Calc
6 2.600 0.950 2.600 4.550 Lateral Concrete Calc
Concrete Wall Properties:
ID Pois UnitWt UW Self f'c Thick Ec
kg/m3 kg/m3 kg/cm2 mm kg/cm2
1 0.20 2322.68 2402.770 281.230 200.000 Calc
0
2 0.20 2322.68 2402.770 281.230 200.000 Calc
0
3 0.20 2322.68 2402.770 281.230 200.000 Calc
0
4 0.20 2322.68 2402.770 281.230 200.000 Calc
0
5 0.20 2322.68 2402.770 281.230 200.000 Calc
0
6 0.20 2322.68 2402.770 281.230 200.000 Calc
0

User Input Line Loads:


Load Properties ID Xi Yi Xj Yj
m m m m
DL: Veneer@StemWall 0.10 4.55 2.60 4.55
DL: Veneer@StemWall 0.10 0.95 0.10 4.55
DL: Veneer@StemWall 2.60 0.95 2.60 4.55
DL: Veneer@StemWall 2.00 0.10 2.60 0.95
DL: Veneer@StemWall 0.70 0.10 2.00 0.10
DL: Veneer@StemWall 0.10 0.95 0.70 0.10

D15
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/2019 16:47:13

D16
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/2019 16:47:38

D17
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/2019 16:48:38

D18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/2019 16:49:55

ELEVATION @ GRIDLINE 2'

D19
B C'
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/2019 16:51:25

ELEVATION @ GRIDLINE C'

D20
1' 2'
RAM Structural System V16.00.00.28. - Floor Plan: Top of stem wall
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

C'
C
1 3

B2

B B

B1 1 2
5
2

A'
4
A
1' 2'

D21

1 1.1 1.2 2
RAM Structural System V16.00.00.28. - Floor Plan: Top of stem wall
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

C DL: Veneer@StemWall
C'
DL: Veneer@StemWall

DL: Veneer@StemWall

B2
all
DL

B B
W
:
Ve

em

B1
ne

St
er

r@
@

ee
St

en
em

:V
W

DL

DL: Veneer@StemWall
all

A'
A
1' 2'

D22

1 1.1 1.2 2
RAM Structural System V16.00.00.28. - Floor Plan: Roof
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

1R3 2R1

CR1

C 3

AC2

CR2
1

AC3 6

B
1 2
AC4
5
2

4
A
AR1'

AR2' 1 1.1 1.2 2

1R1 1R2 2R2 2R3

D23
RAM Structural System V16.00.00.28. - Floor Plan: Roof
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

1R3 2R1

CR1

AC2

CR2

AC3 200 Slab

B
AC4

A
AR1'

AR2' 1 1.1 1.2 2

1R1 1R2 2R2 2R3

D24
RAM Structural System V16.00.00.28. - Floor Plan: Roof
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

1R3 2R1

CR1

R-A1
C

AC2

R-A2
CR2

AC3

R-A3

B
AC4

A R-A4
AR1'

AR2' 1 1.1 1.2 2

1R1 1R2 2R2 2R3

D25
RAM Structural System V16.00.00.28. - Floor Plan: Roof
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/24/19 17:04:51

1R3 2R1
DL: Parapet

CR1

DL: Veneer @ Roof


C
DL: Parapet

DL: Parapet
AC2
DL: Veneer @ Roof

DL: Veneer @ Roof


DL: Parapet DL: Parapet

CR2

AC3
DL: Parapet

DL: Parapet
B
DL

of
Ro
:V

r@
en
ee

ee

AC4
r

en
@

:V
Ro

DL
of

DL: Veneer @ Roof

A
AR1'
t
D

pe
L:

ra
Pa

Pa
r
ap

L:
et

DL: Parapet

AR2' 1 1.1 1.2 2

1R1 1R2 2R2 2R3

D26
Criteria, Mass and Exposure Data
RAM Frame 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

CRITERIA:
Rigid End Zones: Ignore Effects
Member Force Output: At Face of Joint
P-Delta: Yes Scale Factor: 1.00
Ground Level: TO STEM WALL
Mesh Criteria :
Max. Distance Between Nodes on Mesh Line (m) : 1.22
Merge Node Tolerance (mm) : 0.2540
Geometry Tolerance (mm) : 0.1270
Walls Out-of-plane Stiffness Not Included in Analysis.
Sign considered for Dynamic Load Case Results.
Rigid Links Included at Fixed Beam-to-Wall Locations
Eigenvalue Analysis : Eigen Vectors (Subspace Iteration)
DIAPHRAGM DATA:
Story Diaph # Diaph Type
TO ROOF 1 Rigid

Disconnect Internal Nodes of Beams: Yes


Disconnect Nodes outside Slab Boundary: Yes
STORY MASS DATA:
Includes Self Mass of:
Beams
Columns (Half mass of columns above and below)
Walls (Half mass of walls above and below)
Slabs/Deck

Calculated Values:
Story Diaph # Weight Mass MMI Xm Ym EccX EccY
kg 1000kg 1000kg- m m m m
m2
TO ROOF 1 58.71 58.71 392 1.35 2.05 0.29 0.32
TO STEM WALL None 17.11 17.11 66 1.35 2.30 -- --

Story Diaph # Combine


TO ROOF 1 None
TO STEM WALL None 1-TO ROOF
Combined/Merged Values:
Story Diaph # Weight Mass MMI Xm Ym EccX EccY
1000kg 1000kg 1000kg- m m m m
m2
TO ROOF 1 75.8 75.82 459 1.35 2.11 0.29 0.32
WIND EXPOSURE DATA:
Calculated Values:
Story Diaph # Building Extents (m) Expose Parapet
D27
Criteria, Mass and Exposure Data
RAM Frame 16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
Min X Max X Min Y Max Y m
TO ROOF 1 -1.55 4.25 -1.07 5.41 Full 0.80
STORY GRAVITY LOADS DATA:
Includes Weight of:
Beams
Columns
Walls
Slabs/Deck

Live Load Reduction (Calculated)


Reducible : 0.00 %
Storage : 0.00 %
Roof : 15.44 %

Calculated Values:
Story Diaph # Dead Xc Yc Live Xc Yc
kg m m kg m m
TO ROOF 1 63063.56 1.35 2.04 0.00 0.00 0.00
TO STEM WALL None 16342.36 1.35 2.40 0.00 0.00 0.00

Story Diaph # Roof Xc Yc Combine


kg m m
TO ROOF 1 2839.92 1.35 1.96 None
TO STEM WALL None 0.00 0.00 0.00 1-TO
ROOF

User Specified Values:


Story Diaph # Dead Xc Yc Live Xc Yc
kg m m kg m m
TO ROOF 1 79405.92 1.35 2.12 0.00 0.00 0.00

Story Diaph # Roof Xc Yc


kg m m
TO ROOF 1 2839.9 1.35 1.96

D28
Frame Model Data
RAM Frame 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

STORY DATA:
Level Story Label Layout Type Height
m
2 TO ROOF Roof 3.20
1 TO STEM WALL Top of stem wall 1.00

COLUMN SECTION PROPERTIES:


Concrete:
# Label Shape Depth/Diam Width Cracked Factors
mm mm Bending Axial Torsion
1 400X400 Rectangle 400.00 400.00 0.70 1.00 1.00
FRAME MEMBERS
Frame #0:
Level: TO ROOF

Concrete Wall:
# X Y Z Pois UnitWt UW Self f'c Thick Group
m m m kg/m3 kg/m3 kg/cm2
1 0.100 0.950 4.200 0.20 2322.7 2402.8 281.230 200.0 0
0.100 4.550 4.200
0.100 0.950 1.000
0.100 4.550 1.000
3 0.100 4.550 4.200 0.20 2322.7 2402.8 281.230 200.0 0
2.600 4.550 4.200
0.100 4.550 1.000
2.600 4.550 1.000
6 2.600 0.950 4.200 0.20 2322.7 2402.8 281.230 200.0 0
2.600 4.550 4.200
2.600 0.950 1.000
2.600 4.550 1.000

Wall Openings:
Wall # Opening # Reference Corner X Y Width Height
m m mm mm
1 1 Lower Right 2.000 0.000 1521.000 2200.000
3 1 Lower Left 1.703 1.800 600.000 400.000
6 1 Lower Right 2.000 0.000 1521.000 2200.000

Wall Crack Factors:


Wall # Membrane Bending
1 0.350 1.000
3 0.350 1.000
6 0.350 1.000
D29
Frame Model Data
RAM Frame 16.00.00.28 Page 2/5
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

Level: TO STEM WALL

Concrete Wall:
# X Y Z Pois UnitWt UW Self f'c Thick Group
m m m kg/m3 kg/m3 kg/cm2
1 0.100 0.950 1.000 0.20 2322.7 2402.8 281.230 200.0 0
0.100 4.550 1.000
0.100 0.950 0.000
0.100 4.550 0.000
3 0.100 4.550 1.000 0.20 2322.7 2402.8 281.230 200.0 0
2.600 4.550 1.000
0.100 4.550 0.000
2.600 4.550 0.000
6 2.600 0.950 1.000 0.20 2322.7 2402.8 281.230 200.0 0
2.600 4.550 1.000
2.600 0.950 0.000
2.600 4.550 0.000

Wall Crack Factors:


Wall # Membrane Bending
1 0.350 1.000
3 0.350 1.000
6 0.350 1.000

NODES:
# X Y Z Fdtn Diaphr
m m m (Diaph.# - Story Name)
1 0.100 0.950 4.200 N 1 - TO ROOF
2 0.100 4.550 4.200 N 1 - TO ROOF
3 2.600 0.950 4.200 N 1 - TO ROOF
4 2.600 4.550 4.200 N 1 - TO ROOF
5 0.100 0.950 1.000 N None
6 0.100 4.550 1.000 N None
7 2.600 0.950 1.000 N None
8 2.600 4.550 1.000 N None
9 0.100 0.950 0.000 Y --
10 0.100 4.550 0.000 Y --
11 2.600 0.950 0.000 Y --
12 2.600 4.550 0.000 Y --
13 0.100 1.060 3.688 N None
14 0.100 1.029 3.200 N None
15 0.100 1.850 3.704 N None
16 0.100 1.789 3.200 N None
17 0.100 0.950 1.800 N None
18 0.100 0.989 1.947 N None
D30
Frame Model Data
RAM Frame 16.00.00.28 Page 3/5
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
# X Y Z Fdtn Diaphr
19 0.100 0.989 1.000 N None
20 0.100 2.651 3.704 N None
21 0.100 2.550 3.200 N None
22 0.100 3.616 3.513 N None
23 0.100 3.546 2.817 N None
24 0.100 3.551 1.946 N None
25 0.100 2.550 2.100 N None
26 0.100 0.978 2.873 N None
27 0.100 0.978 3.321 N None
28 0.100 2.750 4.200 N 1 - TO ROOF
29 0.100 1.850 4.200 N 1 - TO ROOF
30 0.100 1.029 1.000 N None
31 0.100 1.029 2.100 N None
32 0.100 0.950 2.600 N None
33 0.100 4.550 2.600 N None
34 0.100 4.550 3.400 N None
35 0.100 3.650 4.200 N 1 - TO ROOF
36 0.100 2.550 1.000 N None
37 0.100 3.550 1.000 N None
38 0.100 4.550 1.800 N None
39 0.100 0.950 3.400 N None
40 1.975 4.550 4.200 N 1 - TO ROOF
41 1.350 4.550 4.200 N 1 - TO ROOF
42 2.033 4.550 3.635 N None
43 1.612 4.550 3.536 N None
44 1.690 4.550 2.544 N None
45 1.573 4.550 2.158 N None
46 2.142 4.550 2.604 N None
47 2.143 4.550 2.306 N None
48 1.484 4.550 1.634 N None
49 1.350 4.550 1.000 N None
50 2.105 4.550 1.701 N None
51 1.975 4.550 1.000 N None
52 0.725 4.550 2.866 N None
53 1.231 4.550 2.652 N None
54 0.911 4.550 2.285 N None
55 0.725 4.550 1.000 N None
56 0.773 4.550 1.683 N None
57 2.600 4.550 3.400 N None
58 2.488 4.550 3.175 N None
59 2.476 4.550 3.572 N None
60 1.225 4.550 3.549 N None
61 1.150 4.550 3.080 N None
62 1.556 4.550 3.233 N None
63 1.520 4.550 2.895 N
D31 None
Frame Model Data
RAM Frame 16.00.00.28 Page 4/5
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
# X Y Z Fdtn Diaphr
64 0.703 4.550 3.494 N None
65 0.725 4.550 4.200 N 1 - TO ROOF
66 1.803 4.550 3.200 N None
67 2.103 4.550 3.200 N None
68 2.403 4.550 3.200 N None
69 2.600 4.550 2.600 N None
70 2.486 4.550 2.742 N None
71 2.403 4.550 2.800 N None
72 2.103 4.550 2.800 N None
73 1.803 4.550 2.800 N None
74 2.600 4.550 1.800 N None
75 2.403 4.550 3.000 N None
76 1.803 4.550 3.000 N None
77 2.600 1.060 3.688 N None
78 2.600 1.029 3.200 N None
79 2.600 1.850 3.704 N None
80 2.600 1.789 3.200 N None
81 2.600 0.950 1.800 N None
82 2.600 0.989 1.947 N None
83 2.600 0.990 1.000 N None
84 2.600 2.651 3.704 N None
85 2.600 2.550 3.200 N None
86 2.600 3.616 3.513 N None
87 2.600 3.546 2.817 N None
88 2.600 3.551 1.946 N None
89 2.600 2.550 2.100 N None
90 2.600 0.978 2.873 N None
91 2.600 0.978 3.321 N None
92 2.600 2.750 4.200 N 1 - TO ROOF
93 2.600 1.850 4.200 N 1 - TO ROOF
94 2.600 1.029 1.000 N None
95 2.600 1.029 2.100 N None
96 2.600 0.950 2.600 N None
97 2.600 3.650 4.200 N 1 - TO ROOF
98 2.600 2.550 1.000 N None
99 2.600 3.550 1.000 N None
100 2.600 0.950 3.400 N None
101 0.100 1.789 1.000 N None
102 0.100 1.882 0.529 N None
103 0.100 1.311 0.571 N None
104 0.100 3.650 0.000 Y --
105 0.100 3.600 0.501 N None
106 0.100 4.550 0.500 N None
107 0.100 1.089 0.653 N None
108 0.100 0.950 0.500 N
D32 None
Frame Model Data
RAM Frame 16.00.00.28 Page 5/5
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
# X Y Z Fdtn Diaphr
109 0.100 1.850 0.000 Y --
110 0.100 2.750 0.000 Y --
111 0.100 2.649 0.503 N None
112 0.725 4.550 0.500 N None
113 0.725 4.550 0.000 Y --
114 1.350 4.550 0.500 N None
115 1.350 4.550 0.000 Y --
116 1.975 4.550 0.500 N None
117 1.975 4.550 0.000 Y --
118 2.600 4.550 0.500 N None
119 2.600 1.789 1.000 N None
120 2.600 1.882 0.529 N None
121 2.600 1.311 0.571 N None
122 2.600 3.650 0.000 Y --
123 2.600 3.600 0.501 N None
124 2.600 1.089 0.653 N None
125 2.600 0.950 0.500 N None
126 2.600 1.850 0.000 Y --
127 2.600 2.750 0.000 Y --
128 2.600 2.649 0.503 N None

D33
Exposure Boundaries
RAM Frame 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

Profile X-Axis

TO ROOF - Diaph #1 2
1
Base
Zone Start (m) End (m) Height (m)
1 -1.5470 4.2470 3.2000
2 -1.5470 4.2470 0.8000 Parapet

D34
Exposure Boundaries
RAM Frame 16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

Profile Y-Axis

TO ROOF - Diaph #1 2
1
Base
Zone Start (m) End (m) Height (m)
1 -1.0750 5.4110 3.2000
2 -1.0750 5.4110 0.8000 Parapet

D35
Loads and Applied Forces
RAM Frame 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

LOAD CASE: EQ
Seismic ASCE 7-10 Equivalent Lateral Force
Site Class: D Importance Factor: 1.50 Ss: 0.370 g S1: 0.170 g TL: 12.00 s
Fa: 1.504 Fv: 2.120 SDs: 0.371 g SD1: 0.240 g
Occupancy Category: IV Seismic Design Category: D
Provisions for: Force
Ground Level: TO STEM WALL

Dir Eccent R Ta Equation Building Period-T


X + And - 5.0 Std,Ct=0.020,x=0.75 Use Ta
Y + And - 5.0 Std,Ct=0.020,x=0.75 Use Ta

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
X 0.117 1.460 0.117 0.117 0.111 0.618 0.024 0.111 1.000

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
Y 0.117 1.460 0.117 0.117 0.111 0.618 0.024 0.111 1.000

Total Building Weight (kg) = 58758.34

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 0.00 1.35 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 0.00
_________ _________
6539.57 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 0.00 1.35 1.78

D36
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 2/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 0.00
_________ _________
6539.57 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 0.00 6539.57 1.64 2.11

APPLIED STORY FORCES


Type: EQ_ASCE710_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 0.00 6539.57
_________ _________
0.00 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 0.00 6539.57 1.06 2.11

APPLIED STORY FORCES


Type: EQ_ASCE710_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 0.00 6539.57
_________ _________
0.00 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D37 6539.57 1961.87 1.64 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 3/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 1961.87
_________ _________
6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 -1961.87 1.64 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 -1961.87
_________ _________
6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -6539.57 1961.87 1.64 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 1961.87
_________ _________
-6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D38 -6539.57 -1961.87 1.64 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 4/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 -1961.87
_________ _________
-6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 6539.57 1.64 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 6539.57
_________ _________
1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 -6539.57 1.64 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 -6539.57
_________ _________
1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D39 -1961.87 6539.57 1.64 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 5/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 6539.57
_________ _________
-1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -1961.87 -6539.57 1.64 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 -6539.57
_________ _________
-1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 1961.87 1.06 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 1961.87
_________ _________
6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D40 6539.57 -1961.87 1.06 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 6/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 -1961.87
_________ _________
6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -6539.57 1961.87 1.06 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 1961.87
_________ _________
-6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -6539.57 -1961.87 1.06 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 -1961.87
_________ _________
-6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D41 1961.87 6539.57 1.06 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 7/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 6539.57
_________ _________
1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 -6539.57 1.06 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 -6539.57
_________ _________
1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -1961.87 6539.57 1.06 2.43

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 6539.57
_________ _________
-1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D42 -1961.87 -6539.57 1.06 2.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 8/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 -6539.57
_________ _________
-1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 1961.87 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 1961.87
_________ _________
6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 -1961.87 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 -1961.87
_________ _________
6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D43 -6539.57 1961.87 1.64 1.78
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 9/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 1961.87
_________ _________
-6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -6539.57 -1961.87 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 -1961.87
_________ _________
-6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 6539.57 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 6539.57
_________ _________
1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D44 1961.87 -6539.57 1.64 1.78
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 10/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 -6539.57
_________ _________
1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -1961.87 6539.57 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 6539.57
_________ _________
-1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -1961.87 -6539.57 1.64 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 -6539.57
_________ _________
-1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D45 6539.57 1961.87 1.06 1.78
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 11/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 1961.87
_________ _________
6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 6539.57 -1961.87 1.06 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 6539.57 -1961.87
_________ _________
6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -6539.57 1961.87 1.06 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 1961.87
_________ _________
-6539.57 1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D46 -6539.57 -1961.87 1.06 1.78
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 12/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -6539.57 -1961.87
_________ _________
-6539.57 -1961.87

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 6539.57 1.06 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 6539.57
_________ _________
1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1961.87 -6539.57 1.06 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1961.87 -6539.57
_________ _________
1961.87 -6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D47 -1961.87 6539.57 1.06 1.78
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 13/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 6539.57
_________ _________
-1961.87 6539.57

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 -1961.87 -6539.57 1.06 1.78

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 -1961.87 -6539.57
_________ _________
-1961.87 -6539.57

D48
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 14/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

LOAD CASE: WL
Wind ASCE 7-10
Exposure: C
Basic Wind Speed (km/h): 185.0
Apply Directionality Factor, Kd = 0.85
Use Topography Factor, Kzt: 1.00
Use Calculated Frequency for X-Dir.
Use Calculated Frequency for Y-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for X-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for Y-Dir.
Damping Ratio for Flexible Structures= 0.01
Mean Roof Height (m): Top Story Height + Parapet = 4.00
Ground Level: TO STEM WALL
WIND PRESSURES:
X-Direction: Natural Frequency = 2.494 Structure is Rigid
Y-Direction: Natural Frequency = 9.191 Structure is Rigid
CpWindward = 0.80 qLeeward (qh) = 119.18 kg/m2
GCpn (Parapet): Windward = 1.50 Leeward = -1.00
Height Kz Kzt qz Gust Factor G CpLeeward Pressure (kg/m2)
m kg/m2 X Y X Y X Y
4.00 0.849 1.000 119.175 ---- ---- ---- ---- 297.938 297.938
3.20 0.849 1.000 119.175 0.850 0.850 -0.500 -0.476 131.689 129.269
0.00 0.849 1.000 119.175 0.850 0.850 -0.500 -0.476 131.689 129.269

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_1_X
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 2912.57 0.00 1.35 2.17

APPLIED STORY FORCES


Type: Wind_ASCE710_1_X
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 2912.57 0.00
_________ _________
2912.57 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_1_Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D49 0.00 2579.39 1.35 2.17
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 15/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: Wind_ASCE710_1_Y
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 0.00 2579.39
_________ _________
0.00 2579.39

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_X+E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 2184.43 0.00 1.35 3.14

APPLIED STORY FORCES


Type: Wind_ASCE710_2_X+E
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 2184.43 0.00
_________ _________
2184.43 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_X-E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 2184.43 0.00 1.35 1.20

APPLIED STORY FORCES


Type: Wind_ASCE710_2_X-E
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 2184.43 0.00
_________ _________
2184.43 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_Y+E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D50 0.00 1934.54 2.22 2.17
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 16/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: Wind_ASCE710_2_Y+E
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 0.00 1934.54
_________ _________
0.00 1934.54

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_Y-E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 0.00 1934.54 0.48 2.17

APPLIED STORY FORCES


Type: Wind_ASCE710_2_Y-E
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 0.00 1934.54
_________ _________
0.00 1934.54

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_3_X+Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 2184.43 1934.54 1.35 2.17

APPLIED STORY FORCES


Type: Wind_ASCE710_3_X+Y
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 2184.43 1934.54
_________ _________
2184.43 1934.54

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_3_X-Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D51 2184.43 -1934.54 1.35 2.17
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 17/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: Wind_ASCE710_3_X-Y
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 2184.43 -1934.54
_________ _________
2184.43 -1934.54

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X+Y_CW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1638.32 1450.91 0.48 3.14

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X+Y_CW
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1638.32 1450.91
_________ _________
1638.32 1450.91

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X+Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1638.32 1450.91 2.22 1.20

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X+Y_CCW
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1638.32 1450.91
_________ _________
1638.32 1450.91

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X-Y_CW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 D52 1638.32 -1450.91 2.22 3.14
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 18/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X-Y_CW
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1638.32 -1450.91
_________ _________
1638.32 -1450.91

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X-Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 3.20 1638.32 -1450.91 0.48 1.20

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X-Y_CCW
Level Ht Fx Fy
m kg kg
TO ROOF 3.20 1638.32 -1450.91
_________ _________
1638.32 -1450.91

D53
Story Displacements
RAM Frame 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
Building Code: IBC

CRITERIA:
Rigid End Zones: Ignore Effects
Member Force Output: At Face of Joint
P-Delta: Yes Scale Factor: 1.00
Ground Level: TO STEM WALL
Mesh Criteria :
Max. Distance Between Nodes on Mesh Line (m) : 1.22
Merge Node Tolerance (mm) : 0.2540
Geometry Tolerance (mm) : 0.1270
Walls Out-of-plane Stiffness Not Included in Analysis.
Sign considered for Dynamic Load Case Results.
Rigid Links Included at Fixed Beam-to-Wall Locations
Eigenvalue Analysis : Eigen Vectors (Subspace Iteration)
LOAD CASE DEFINITIONS:
D DeadLoad RAMUSER
Rfp PosRoofLiveLoad RAMUSER
E1 EQ EQ_ASCE710_X_+E_F
E2 EQ EQ_ASCE710_X_-E_F
E3 EQ EQ_ASCE710_Y_+E_F
E4 EQ EQ_ASCE710_Y_-E_F
E5 EQ EQ_ASCE710_X_+E_0.3Y_+E_F
E6 EQ EQ_ASCE710_X_+E_-0.3Y_+E_F
E7 EQ EQ_ASCE710_-X_+E_0.3Y_+E_F
E8 EQ EQ_ASCE710_-X_+E_-0.3Y_+E_F
E9 EQ EQ_ASCE710_0.3X_+E_Y_+E_F
E10 EQ EQ_ASCE710_0.3X_+E_-Y_+E_F
E11 EQ EQ_ASCE710_-0.3X_+E_Y_+E_F
E12 EQ EQ_ASCE710_-0.3X_+E_-Y_+E_F
E13 EQ EQ_ASCE710_X_+E_0.3Y_-E_F
E14 EQ EQ_ASCE710_X_+E_-0.3Y_-E_F
E15 EQ EQ_ASCE710_-X_+E_0.3Y_-E_F
E16 EQ EQ_ASCE710_-X_+E_-0.3Y_-E_F
E17 EQ EQ_ASCE710_0.3X_+E_Y_-E_F
E18 EQ EQ_ASCE710_0.3X_+E_-Y_-E_F
E19 EQ EQ_ASCE710_-0.3X_+E_Y_-E_F
E20 EQ EQ_ASCE710_-0.3X_+E_-Y_-E_F
E21 EQ EQ_ASCE710_X_-E_0.3Y_+E_F
E22 EQ EQ_ASCE710_X_-E_-0.3Y_+E_F
E23 EQ EQ_ASCE710_-X_-E_0.3Y_+E_F
E24 EQ EQ_ASCE710_-X_-E_-0.3Y_+E_F
E25 EQ EQ_ASCE710_0.3X_-E_Y_+E_F
E26 EQ EQ_ASCE710_0.3X_-E_-Y_+E_F
E27 EQ EQ_ASCE710_-0.3X_-E_Y_+E_F
E28 EQ EQ_ASCE710_-0.3X_-E_-Y_+E_F
D54
Story Displacements
RAM Frame 16.00.00.28 Page 2/3
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
Building Code: IBC
E29 EQ EQ_ASCE710_X_-E_0.3Y_-E_F
E30 EQ EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 EQ EQ_ASCE710_-X_-E_0.3Y_-E_F
E32 EQ EQ_ASCE710_-X_-E_-0.3Y_-E_F
E33 EQ EQ_ASCE710_0.3X_-E_Y_-E_F
E34 EQ EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 EQ EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 EQ EQ_ASCE710_-0.3X_-E_-Y_-E_F
W1 WL Wind_ASCE710_1_X
W2 WL Wind_ASCE710_1_Y
W3 WL Wind_ASCE710_2_X+E
W4 WL Wind_ASCE710_2_X-E
W5 WL Wind_ASCE710_2_Y+E
W6 WL Wind_ASCE710_2_Y-E
W7 WL Wind_ASCE710_3_X+Y
W8 WL Wind_ASCE710_3_X-Y
W9 WL Wind_ASCE710_4_X+Y_CW
W10 WL Wind_ASCE710_4_X+Y_CCW
W11 WL Wind_ASCE710_4_X-Y_CW
W12 WL Wind_ASCE710_4_X-Y_CCW

Level: TO ROOF, Diaph: 1


Center of Mass (m): (1.35, 2.05)
LdC Disp X Disp Y Theta Z
mm mm rad
D 0.00640 -0.22985 0.00000
Rfp 0.00017 -0.01758 0.00000
E1 2.15613 0.00047 0.00057
E2 2.56797 0.00115 0.00070
E3 0.18476 0.25395 0.00006
E4 -0.18314 0.25334 -0.00006
E5 2.21156 0.07665 0.00059
E6 2.10071 -0.07572 0.00055
E7 -2.10071 0.07572 -0.00055
E8 -2.21156 -0.07665 -0.00059
E9 0.83160 0.25409 0.00023
E10 0.46208 -0.25381 0.00011
E11 -0.46208 0.25381 -0.00011
E12 -0.83160 -0.25409 -0.00023
E13 2.10119 0.07647 0.00055
E14 2.21108 -0.07554 0.00059
E15 -2.21108 0.07554 -0.00059
E16 -2.10119 -0.07647 -0.00055
E17 0.46370 0.25348 0.00012
E18 0.82998 D55
-0.25320 0.00023
Story Displacements
RAM Frame 16.00.00.28 Page 3/3
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:10:11
Building Code: IBC
E19 -0.82998 0.25320 -0.00023
E20 -0.46370 -0.25348 -0.00012
E21 2.62340 0.07733 0.00072
E22 2.51255 -0.07504 0.00068
E23 -2.51255 0.07504 -0.00068
E24 -2.62340 -0.07733 -0.00072
E25 0.95515 0.25429 0.00027
E26 0.58564 -0.25361 0.00015
E27 -0.58564 0.25361 -0.00015
E28 -0.95515 -0.25429 -0.00027
E29 2.51303 0.07715 0.00068
E30 2.62292 -0.07486 0.00072
E31 -2.62292 0.07486 -0.00072
E32 -2.51303 -0.07715 -0.00068
E33 0.58725 0.25369 0.00015
E34 0.95353 -0.25300 0.00027
E35 -0.95353 0.25300 -0.00027
E36 -0.58725 -0.25369 -0.00015
W1 1.03465 0.00033 0.00028
W2 0.00030 0.10005 0.00000
W3 0.56963 -0.00009 0.00014
W4 0.98234 0.00059 0.00027
W5 0.16347 0.07530 0.00005
W6 -0.16303 0.07477 -0.00005
W7 0.77621 0.07528 0.00021
W8 0.77576 -0.07479 0.00021
W9 0.30496 0.05601 0.00007
W10 0.85935 0.05692 0.00024
W11 0.30462 -0.05655 0.00007
W12 0.85902 -0.05563 0.00024

D56
Concrete Analysis Criteria
RAM Concrete Analysis v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:14:53
Building Code: IBC Concrete Code: ACI 318-14

MEMBER ANALYSIS CRITERIA - GLOBAL


Concrete Design Code:
ACI 318-14
Analysis :
Number of stations per beam: 10
Max spacing between stations (cm): 30.00
Rigid End Zone : Ignore
Torsional Cracked Factor from section property: Yes
Skip-load Live Load on Beam Line beams : Yes
Skip-load Live Load on the Non-beam Line beams : Yes
Consider Live Load Reduction : Yes
Consider Column Slenderness : Yes
Pin Base of Gravity Concrete Columns: No
Pin Base of Column on Transfer Member: No
Pin Top of Gravity Columns: No
Remove Diaphragm Constraint on Sloped Floors: No
Load Polygons as Load Cases on Two-way deck: No
Ignore Wall Stiffness on Above Story: No
Include Out-of-Plane Stiffness for One-Way Decks Yes
in Hybrid Slabs:
Merge Node Tolerance(cm): 0.0125
Max. Distance Allowed Between Nodes(cm): 100.0000
Geometric Tolerance(cm): 0.0250
Hard Node Density Factor: 1.0
Solver Type: In-core Sparse

Sidesway: Braced

Column Effective Length :


kx: Code
ky: Code

Column Bracing:
Slab braces column
Max Angle for which Beam Braces Column: 45.00 deg

Source of Column/Wall Forces :


Use RAM Concrete Analysis Forces at all levels.

MEMBER ANALYSIS CRITERIA - ASSIGNED


Level: TO ROOF
Concrete Column:

D57
Concrete Analysis Criteria
RAM Concrete Analysis v16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:14:53
Building Code: IBC Concrete Code: ACI 318-14
# Effective Length SideSway
kx ky Major Minor
1 Global Global Global Global
2 Global Global Global Global

Level: TO STEM WALL


Concrete Column:
# Effective Length SideSway
kx ky Major Minor
1 Global Global Global Global
2 Global Global Global Global

D58
Concrete Model Data
RAM Concrete Analysis v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:14:53
Building Code: IBC Concrete Code: ACI 318-14

STORY DATA:
Level Story Label Layout Type Height (m)
2 TO ROOF Roof 3.200
1 TO STEM WALL Top of stem wall 1.000

COLUMN SECTION PROPERTIES:


# Label Shape Depth/Diam Width Cracked Factor
mm mm Axial Flex Tors
1 400X400 Rect 400.00 400.00 1.00 0.70 1.00

MEMBERS:

Level: TO ROOF
Columns
# X Y Z-Offset RigMaj RigMin FrameType Fixity Section
m m m mm mm
1 0.10 0.95 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
2 2.60 0.95 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF

Level: TO STEM WALL


Columns
# X Y Z-Offset RigMaj RigMin FrameType Fixity Section
m m m mm mm
1 0.10 0.95 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
2 2.60 0.95 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF

D59
Member Analysis Properties
RAM Concrete Analysis v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:14:53
Building Code: IBC Concrete Code: ACI 318-14

SECTION DIMENSIONS:

Level: TO ROOF

Concrete Columns:
# Label Shape Depth/Diam Width
cm cm
1 400X400 Rect 40.0 40.0
2 400X400 Rect 40.0 40.0

Level: TO STEM WALL

Concrete Columns:
# Label Shape Depth/Diam Width
cm cm
1 400X400 Rect 40.0 40.0
2 400X400 Rect 40.0 40.0

CALCULATED SECTION PROPERTIES:


All calculated inertias include crack section factor reduction.

Level: TO ROOF

Columns:
# Label Shape Ix Iy A J Cracked Factor
cm4 cm4 cm2 cm4 Axial Flex Tors
1 400X400 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
2 400X400 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00

Level: TO STEM WALL

Columns:
# Label Shape Ix Iy A J Cracked Factor
cm4 cm4 cm2 cm4 Axial Flex Tors
1 400X400 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
2 400X400 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00

D60
Concrete Column Design Criteria
RAM Concrete Column v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:20:04
Building Code: IBC Concrete Code: ACI 318-14

COLUMN DESIGN CRITERIA - GLOBAL:


Reinforcement Properties Table: ramgb50010
Code: ACI 318-14
Frame Type:
Special Moment Frame
Load Combination Factors:
ACI 318-99 Sec 21.3.4.1 Dead: 1.20 Live: 1.00 Snow: 0.20
Seismic Design Category: D
Reinforcement:
Clear Bar Spacing - Shear/Transverse Ties (mm) Max: CODE Min: CODE
Clear Bar Spacing - Shear Spiral (mm) Max: CODE Min: CODE
Clear Bar Spacing - Flexure + Axial/Longitudinal (mm) Max: CODE Min: CODE
Reinforcement Ratio Max: CODE Min: CODE
Clear Bar Cover (mm) CODE
Bar Selection:
Transverse Segment Spacing Increment (mm) 304.80
Transverse Bar Spacing Increment (mm) 76.20
Number Of Shear Bar Legs Major: 2 Minor: 2
Design Checks:
Include Torsional Capacity Code Check
Include Max Column Axial Load Limit Code Check
Lateral Column Gravity Design Forces from RAM Concrete Analysis
Lap Splices:
For Bars less than or equal to #6 use Lap Splice 36.00 x d
For Bars greater than #6 use Lap Splice 55.00 x d
Rectangular Bar Patterns:
Bar Pattern Trans Bar Longitudinal Bars Bar Quantity
Name Size Min Size Max Size Top/Bottom Additional
Side Bars
8 (3 x 1) #16 - #16 #12 #16 #16 3 1

D61
Concrete Column Design Criteria
RAM Concrete Column v16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:20:04
Building Code: IBC Concrete Code: ACI 318-14

COLUMN DESIGN CRITERIA - ASSIGNED:

Column Stack Location: (0.10m-0.95m)


Shear Legs
Level Section Major Minor
TO ROOF 400X400 2 2
TO STEM 400X400 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (2.60m-0.95m)


Shear Legs
Level Section Major Minor
TO ROOF 400X400 2 2
TO STEM 400X400 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

D62
Load Combinations
RAM Concrete Column v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14

LOAD CASES:
D DeadLoad RAMUSER
Rfp PosRoofLiveLoad RAMUSER
E1 EQ EQ_ASCE710_X_+E_F
E2 EQ EQ_ASCE710_X_-E_F
E3 EQ EQ_ASCE710_Y_+E_F
E4 EQ EQ_ASCE710_Y_-E_F
E5 EQ EQ_ASCE710_X_+E_0.3Y_+E_F
E6 EQ EQ_ASCE710_X_+E_-0.3Y_+E_F
E7 EQ EQ_ASCE710_-X_+E_0.3Y_+E_F
E8 EQ EQ_ASCE710_-X_+E_-0.3Y_+E_F
E9 EQ EQ_ASCE710_0.3X_+E_Y_+E_F
E10 EQ EQ_ASCE710_0.3X_+E_-Y_+E_F
E11 EQ EQ_ASCE710_-0.3X_+E_Y_+E_F
E12 EQ EQ_ASCE710_-0.3X_+E_-Y_+E_F
E13 EQ EQ_ASCE710_X_+E_0.3Y_-E_F
E14 EQ EQ_ASCE710_X_+E_-0.3Y_-E_F
E15 EQ EQ_ASCE710_-X_+E_0.3Y_-E_F
E16 EQ EQ_ASCE710_-X_+E_-0.3Y_-E_F
E17 EQ EQ_ASCE710_0.3X_+E_Y_-E_F
E18 EQ EQ_ASCE710_0.3X_+E_-Y_-E_F
E19 EQ EQ_ASCE710_-0.3X_+E_Y_-E_F
E20 EQ EQ_ASCE710_-0.3X_+E_-Y_-E_F
E21 EQ EQ_ASCE710_X_-E_0.3Y_+E_F
E22 EQ EQ_ASCE710_X_-E_-0.3Y_+E_F
E23 EQ EQ_ASCE710_-X_-E_0.3Y_+E_F
E24 EQ EQ_ASCE710_-X_-E_-0.3Y_+E_F
E25 EQ EQ_ASCE710_0.3X_-E_Y_+E_F
E26 EQ EQ_ASCE710_0.3X_-E_-Y_+E_F
E27 EQ EQ_ASCE710_-0.3X_-E_Y_+E_F
E28 EQ EQ_ASCE710_-0.3X_-E_-Y_+E_F
E29 EQ EQ_ASCE710_X_-E_0.3Y_-E_F
E30 EQ EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 EQ EQ_ASCE710_-X_-E_0.3Y_-E_F
E32 EQ EQ_ASCE710_-X_-E_-0.3Y_-E_F
E33 EQ EQ_ASCE710_0.3X_-E_Y_-E_F
E34 EQ EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 EQ EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 EQ EQ_ASCE710_-0.3X_-E_-Y_-E_F
W1 WL Wind_ASCE710_1_X
W2 WL Wind_ASCE710_1_Y
W3 WL Wind_ASCE710_2_X+E
W4 WL Wind_ASCE710_2_X-E
W5 WL Wind_ASCE710_2_Y+E
W6 WL D63
Wind_ASCE710_2_Y-E
Load Combinations
RAM Concrete Column v16.00.00.28 Page 2/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
W7 WL Wind_ASCE710_3_X+Y
W8 WL Wind_ASCE710_3_X-Y
W9 WL Wind_ASCE710_4_X+Y_CW
W10 WL Wind_ASCE710_4_X+Y_CCW
W11 WL Wind_ASCE710_4_X-Y_CW
W12 WL Wind_ASCE710_4_X-Y_CCW

COMBINATION CRITERIA:
Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Reducible
Live Load factor f1 (0.5 or 0.500
1.0)
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300

GENERATED COMBINATIONS:
1 * 1.400 D
2 * 1.200 D + 1.600 Rfp
3 * 1.200 D + 1.600 Rfp + 0.500 W1
4 * 1.200 D + 1.600 Rfp + 0.500 W2
5 * 1.200 D + 1.600 Rfp + 0.500 W3
6 * 1.200 D + 1.600 Rfp + 0.500 W4
7 * 1.200 D + 1.600 Rfp + 0.500 W5
8 * 1.200 D + 1.600 Rfp + 0.500 W6
9 * 1.200 D + 1.600 Rfp + 0.500 W7
10 * 1.200 D + 1.600 Rfp + 0.500 W8
11 * 1.200 D + 1.600 Rfp + 0.500 W9
12 * 1.200 D + 1.600 Rfp + 0.500 W10
13 * 1.200 D + 1.600 Rfp + 0.500 W11
14 * 1.200 D + 1.600 Rfp + 0.500 W12
15 * 1.200 D + 1.600 Rfp - 0.500 W1
16 * 1.200 D + 1.600 Rfp - 0.500 W2
17 * 1.200 D + 1.600 Rfp - 0.500 W3
18 * 1.200 D + 1.600 Rfp - 0.500 W4
19 * 1.200 D + 1.600 Rfp - 0.500 W5
20 * 1.200 D + 1.600 Rfp - 0.500 W6
21 * 1.200 D + 1.600 Rfp - 0.500 W7
22 * 1.200 D + 1.600 Rfp - 0.500 W8
23 * 1.200 D + 1.600 Rfp - 0.500 W9
24 * 1.200 D + 1.600 Rfp - 0.500 W10
25 * 1.200 D + 1.600 Rfp - 0.500 W11
26 * 1.200 D + 1.600 Rfp - 0.500 W12
27 * 1.200 D + 0.500 Rfp + 1.000 W1
D64
Load Combinations
RAM Concrete Column v16.00.00.28 Page 3/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
28 * 1.200 D + 0.500 Rfp + 1.000 W2
29 * 1.200 D + 0.500 Rfp + 1.000 W3
30 * 1.200 D + 0.500 Rfp + 1.000 W4
31 * 1.200 D + 0.500 Rfp + 1.000 W5
32 * 1.200 D + 0.500 Rfp + 1.000 W6
33 * 1.200 D + 0.500 Rfp + 1.000 W7
34 * 1.200 D + 0.500 Rfp + 1.000 W8
35 * 1.200 D + 0.500 Rfp + 1.000 W9
36 * 1.200 D + 0.500 Rfp + 1.000 W10
37 * 1.200 D + 0.500 Rfp + 1.000 W11
38 * 1.200 D + 0.500 Rfp + 1.000 W12
39 * 1.200 D + 0.500 Rfp - 1.000 W1
40 * 1.200 D + 0.500 Rfp - 1.000 W2
41 * 1.200 D + 0.500 Rfp - 1.000 W3
42 * 1.200 D + 0.500 Rfp - 1.000 W4
43 * 1.200 D + 0.500 Rfp - 1.000 W5
44 * 1.200 D + 0.500 Rfp - 1.000 W6
45 * 1.200 D + 0.500 Rfp - 1.000 W7
46 * 1.200 D + 0.500 Rfp - 1.000 W8
47 * 1.200 D + 0.500 Rfp - 1.000 W9
48 * 1.200 D + 0.500 Rfp - 1.000 W10
49 * 1.200 D + 0.500 Rfp - 1.000 W11
50 * 1.200 D + 0.500 Rfp - 1.000 W12
51 * 1.200 D + 1.000 W1
52 * 1.200 D + 1.000 W2
53 * 1.200 D + 1.000 W3
54 * 1.200 D + 1.000 W4
55 * 1.200 D + 1.000 W5
56 * 1.200 D + 1.000 W6
57 * 1.200 D + 1.000 W7
58 * 1.200 D + 1.000 W8
59 * 1.200 D + 1.000 W9
60 * 1.200 D + 1.000 W10
61 * 1.200 D + 1.000 W11
62 * 1.200 D + 1.000 W12
63 * 1.200 D - 1.000 W1
64 * 1.200 D - 1.000 W2
65 * 1.200 D - 1.000 W3
66 * 1.200 D - 1.000 W4
67 * 1.200 D - 1.000 W5
68 * 1.200 D - 1.000 W6
69 * 1.200 D - 1.000 W7
70 * 1.200 D - 1.000 W8
71 * 1.200 D - 1.000 W9
72 * 1.200 D - 1.000 W10 D65
Load Combinations
RAM Concrete Column v16.00.00.28 Page 4/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
73 * 1.200 D - 1.000 W11
74 * 1.200 D - 1.000 W12
75 * 0.900 D + 1.000 W1
76 * 0.900 D + 1.000 W2
77 * 0.900 D + 1.000 W3
78 * 0.900 D + 1.000 W4
79 * 0.900 D + 1.000 W5
80 * 0.900 D + 1.000 W6
81 * 0.900 D + 1.000 W7
82 * 0.900 D + 1.000 W8
83 * 0.900 D + 1.000 W9
84 * 0.900 D + 1.000 W10
85 * 0.900 D + 1.000 W11
86 * 0.900 D + 1.000 W12
87 * 0.900 D - 1.000 W1
88 * 0.900 D - 1.000 W2
89 * 0.900 D - 1.000 W3
90 * 0.900 D - 1.000 W4
91 * 0.900 D - 1.000 W5
92 * 0.900 D - 1.000 W6
93 * 0.900 D - 1.000 W7
94 * 0.900 D - 1.000 W8
95 * 0.900 D - 1.000 W9
96 * 0.900 D - 1.000 W10
97 * 0.900 D - 1.000 W11
98 * 0.900 D - 1.000 W12
99 * 1.274 D + 1.300 E1
100 * 1.274 D + 1.300 E2
101 * 1.274 D + 1.300 E3
102 * 1.274 D + 1.300 E4
103 * 1.274 D + 1.300 E5
104 * 1.274 D + 1.300 E6
105 * 1.274 D + 1.300 E7
106 * 1.274 D + 1.300 E8
107 * 1.274 D + 1.300 E9
108 * 1.274 D + 1.300 E10
109 * 1.274 D + 1.300 E11
110 * 1.274 D + 1.300 E12
111 * 1.274 D + 1.300 E13
112 * 1.274 D + 1.300 E14
113 * 1.274 D + 1.300 E15
114 * 1.274 D + 1.300 E16
115 * 1.274 D + 1.300 E17
116 * 1.274 D + 1.300 E18
117 * 1.274 D + 1.300 E19 D66
Load Combinations
RAM Concrete Column v16.00.00.28 Page 5/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
118 * 1.274 D + 1.300 E20
119 * 1.274 D + 1.300 E21
120 * 1.274 D + 1.300 E22
121 * 1.274 D + 1.300 E23
122 * 1.274 D + 1.300 E24
123 * 1.274 D + 1.300 E25
124 * 1.274 D + 1.300 E26
125 * 1.274 D + 1.300 E27
126 * 1.274 D + 1.300 E28
127 * 1.274 D + 1.300 E29
128 * 1.274 D + 1.300 E30
129 * 1.274 D + 1.300 E31
130 * 1.274 D + 1.300 E32
131 * 1.274 D + 1.300 E33
132 * 1.274 D + 1.300 E34
133 * 1.274 D + 1.300 E35
134 * 1.274 D + 1.300 E36
135 * 1.274 D - 1.300 E1
136 * 1.274 D - 1.300 E2
137 * 1.274 D - 1.300 E3
138 * 1.274 D - 1.300 E4
139 * 1.274 D - 1.300 E5
140 * 1.274 D - 1.300 E6
141 * 1.274 D - 1.300 E7
142 * 1.274 D - 1.300 E8
143 * 1.274 D - 1.300 E9
144 * 1.274 D - 1.300 E10
145 * 1.274 D - 1.300 E11
146 * 1.274 D - 1.300 E12
147 * 1.274 D - 1.300 E13
148 * 1.274 D - 1.300 E14
149 * 1.274 D - 1.300 E15
150 * 1.274 D - 1.300 E16
151 * 1.274 D - 1.300 E17
152 * 1.274 D - 1.300 E18
153 * 1.274 D - 1.300 E19
154 * 1.274 D - 1.300 E20
155 * 1.274 D - 1.300 E21
156 * 1.274 D - 1.300 E22
157 * 1.274 D - 1.300 E23
158 * 1.274 D - 1.300 E24
159 * 1.274 D - 1.300 E25
160 * 1.274 D - 1.300 E26
161 * 1.274 D - 1.300 E27
162 * 1.274 D - 1.300 E28 D67
Load Combinations
RAM Concrete Column v16.00.00.28 Page 6/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
163 * 1.274 D - 1.300 E29
164 * 1.274 D - 1.300 E30
165 * 1.274 D - 1.300 E31
166 * 1.274 D - 1.300 E32
167 * 1.274 D - 1.300 E33
168 * 1.274 D - 1.300 E34
169 * 1.274 D - 1.300 E35
170 * 1.274 D - 1.300 E36
171 * 0.826 D + 1.300 E1
172 * 0.826 D + 1.300 E2
173 * 0.826 D + 1.300 E3
174 * 0.826 D + 1.300 E4
175 * 0.826 D + 1.300 E5
176 * 0.826 D + 1.300 E6
177 * 0.826 D + 1.300 E7
178 * 0.826 D + 1.300 E8
179 * 0.826 D + 1.300 E9
180 * 0.826 D + 1.300 E10
181 * 0.826 D + 1.300 E11
182 * 0.826 D + 1.300 E12
183 * 0.826 D + 1.300 E13
184 * 0.826 D + 1.300 E14
185 * 0.826 D + 1.300 E15
186 * 0.826 D + 1.300 E16
187 * 0.826 D + 1.300 E17
188 * 0.826 D + 1.300 E18
189 * 0.826 D + 1.300 E19
190 * 0.826 D + 1.300 E20
191 * 0.826 D + 1.300 E21
192 * 0.826 D + 1.300 E22
193 * 0.826 D + 1.300 E23
194 * 0.826 D + 1.300 E24
195 * 0.826 D + 1.300 E25
196 * 0.826 D + 1.300 E26
197 * 0.826 D + 1.300 E27
198 * 0.826 D + 1.300 E28
199 * 0.826 D + 1.300 E29
200 * 0.826 D + 1.300 E30
201 * 0.826 D + 1.300 E31
202 * 0.826 D + 1.300 E32
203 * 0.826 D + 1.300 E33
204 * 0.826 D + 1.300 E34
205 * 0.826 D + 1.300 E35
206 * 0.826 D + 1.300 E36
207 * 0.826 D - 1.300 E1 D68
Load Combinations
RAM Concrete Column v16.00.00.28 Page 7/7
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14
208 * 0.826 D - 1.300 E2
209 * 0.826 D - 1.300 E3
210 * 0.826 D - 1.300 E4
211 * 0.826 D - 1.300 E5
212 * 0.826 D - 1.300 E6
213 * 0.826 D - 1.300 E7
214 * 0.826 D - 1.300 E8
215 * 0.826 D - 1.300 E9
216 * 0.826 D - 1.300 E10
217 * 0.826 D - 1.300 E11
218 * 0.826 D - 1.300 E12
219 * 0.826 D - 1.300 E13
220 * 0.826 D - 1.300 E14
221 * 0.826 D - 1.300 E15
222 * 0.826 D - 1.300 E16
223 * 0.826 D - 1.300 E17
224 * 0.826 D - 1.300 E18
225 * 0.826 D - 1.300 E19
226 * 0.826 D - 1.300 E20
227 * 0.826 D - 1.300 E21
228 * 0.826 D - 1.300 E22
229 * 0.826 D - 1.300 E23
230 * 0.826 D - 1.300 E24
231 * 0.826 D - 1.300 E25
232 * 0.826 D - 1.300 E26
233 * 0.826 D - 1.300 E27
234 * 0.826 D - 1.300 E28
235 * 0.826 D - 1.300 E29
236 * 0.826 D - 1.300 E30
237 * 0.826 D - 1.300 E31
238 * 0.826 D - 1.300 E32
239 * 0.826 D - 1.300 E33
240 * 0.826 D - 1.300 E34
241 * 0.826 D - 1.300 E35
242 * 0.826 D - 1.300 E36

D69
Concrete Column Design Summary
RAM Concrete Column v16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 04/25/19 17:21:16
Building Code: IBC Concrete Code: ACI 318-14

Location: 1' - B
No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
1 TO ROOF 400X400 281.23 8-#16 (3 x 1) 1.01 0.04 #12@96.00 0.00-3200.00 0.37
1 TO STEM WALL 400X400 281.23 8-#16 (3 x 1) 1.01 0.04 N/A

Location: 2' - B
No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
2 TO ROOF 400X400 281.23 8-#16 (3 x 1) 1.01 0.04 #12@96.00 0.00-3200.00 0.37
2 TO STEM WALL 400X400 281.23 8-#16 (3 x 1) 1.01 0.04 N/A

D70
Wall Panel Reinforcing
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Wall Design Group: 1


Bar Pattern Template: Wall Reinf

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
TO ROOF 23 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
24 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
25 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
26 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
27 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
28 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
TO STEM 29 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
WALL
30 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%
31 (1) #16@300 mm oc 0.34% (1) #16@300 mm oc 0.34%

D71
Wall Panel Properties
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Wall Design Group: 1

Story: TO ROOF (4.20 m)


Panel Num Thick (cm) Length (m) f'c fy Height (m) Coords (m)
(kg/cm2) (kg/cm2)
Start End
23 20.00 3.600 281.23 4218.5 3.200 3.200 (0.100, 0.950)
(0.100, 4.550)
24 20.00 2.500 281.23 4218.5 3.200 3.200 (0.100, 4.550)
(2.600, 4.550)
25 20.00 3.600 281.23 4218.5 3.200 3.200 (2.600, 0.950)
(2.600, 4.550)
26 20.00 1.040 281.23 4218.5 3.200 3.200 (0.100, 0.950)
(0.700, 0.100)
27 20.00 1.300 281.23 4218.5 3.200 3.200 (0.700, 0.100)
(2.000, 0.100)
28 20.00 1.040 281.23 4218.5 3.200 3.200 (2.000, 0.100)
(2.600, 0.950)
Story: TO STEM WALL (1.00 m)
Panel Num Thick (cm) Length (m) f'c fy Height (m) Coords (m)
(kg/cm2) (kg/cm2)
Start End
29 20.00 2.500 281.23 4218.5 1.000 1.000 (0.100, 4.550)
(2.600, 4.550)
30 20.00 3.600 281.23 4218.5 1.000 1.000 (2.600, 0.950)
(2.600, 4.550)
31 20.00 3.600 281.23 4218.5 1.000 1.000 (0.100, 0.950)
(0.100, 4.550)

D72
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Section Cut ID: SC1V:67 (Vertical)


Story: TO STEM WALL
Ag = 2000 cm2 Imaj = 66667 cm4 Imin = 1666667 cm4
Wall Design Group: 1
Design Status: PASS

SC1V:67

Min

Maj
ELEVATION VIEW

Axial/Flexural Results:
Interaction: 0.064 OK
Pu = -1575.88 kgf phiPn = -24663.15 kgf
Mu = 364.0 kg.m at Beta = -0.0 deg CCW from Major axis
Controlling Load Combo: 1.274 D + 1.300 E31 (LC 129)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1V:67:
Length = 1.00 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 5086.3 kgf phiVn = 27091.9 kgf OK
Controlling Load Combo: 1.274 D - 1.300 E31 (LC 165)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Horiz Reinf Ratio: Limit: 0.250% Actual: 0.503% (11.6.2) OK
Segment SC1V:67:
Max Horiz Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.3.1) OK
Min Horiz Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
D73
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Section Cut ID: SC1H:70 (Horizontal)


Story: TO STEM WALL
Ag = 19400 cm2 Imaj = 276468326 cm4 Imin = 252021676 cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:70C

SC1H:70A

SC1H:70B
Min

Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.029 OK
Pu = 60024.70 kgf phiPn = 2073359.50 kgf
Mu = 40390.8 kg.m at Beta = -13.6 deg CCW from Major axis
Controlling Load Combo: 1.274 D + 1.300 E28 (LC 126)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:70A:
Length = 2.50 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 8562.0 kgf phiVn = 69087.6 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E21 (LC 119)
Code Ref: 11.5.4.5

Segment SC1H:70B:
Length = 3.60 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat:
D74
#16@300 mm oc
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14
Shear Results:
Vu = 11085.7 kgf phiVn = 99486.2 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E24 (LC 122)
Code Ref: 11.5.4.5

Segment SC1H:70C:
Length = 3.60 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 11085.7 kgf phiVn = 99486.2 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E30 (LC 128)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.383% (11.6.2) OK
Segment SC1H:70A:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK
Segment SC1H:70B:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK
Segment SC1H:70C:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK

D75
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Section Cut ID: SC1V:25 (Vertical)


Story: TO ROOF
Ag = 6400 cm2 Imaj = 213333 cm4 Imin = 54613345 cm4
Wall Design Group: 1
Design Status: PASS

SC1V:25

Min

Maj
ELEVATION VIEW

Axial/Flexural Results:
Interaction: 0.027 OK
Pu = -410.96 kgf phiPn = -15452.21 kgf
Mu = 3322.8 kg.m at Beta = 0.0 deg CCW from Major axis
Controlling Load Combo: 1.274 D + 1.300 E16 (LC 114)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1V:25:
Length = 3.20 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 10157.6 kgf phiVn = 88369.8 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E16 (LC 114)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Horiz Reinf Ratio: Limit: 0.250% Actual: 0.408% (11.6.2) OK
Segment SC1V:25:
Max Horiz Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.3.1) OK
Min Horiz Bar Spacing Limit: 25 mm Actual: D76
284 mm (25.2.1) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK

D77
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14

Section Cut ID: SC1H:75 (Horizontal)


Story: TO ROOF
Ag = 13000 cm2 Imaj = 151808338 cm4 Imin = 57848412 cm4
Major Axis Orientation: 0.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:75B

SC1H:75A SC1H:75C

Min

Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.048 OK
Pu = 36861.55 kgf phiPn = 768412.13 kgf
Mu = 31212.3 kg.m at Beta = -75.4 deg CCW from Major axis
Controlling Load Combo: 1.274 D + 1.300 E34 (LC 132)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:75A:
Length = 2.00 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 10838.0 kgf phiVn = 55270.1 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E31 (LC 129)
Code Ref: 11.5.4.5

Segment SC1H:75B:
Length = 2.50 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc D78#16@300 mm oc
Horiz Bar Pat:
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
Database: D - Guard House 05/01/19 12:15:24
Design Code: ACI 318-14
Shear Results:
Vu = 8562.0 kgf phiVn = 69087.6 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E2 (LC 100)
Code Ref: 11.5.4.5

Segment SC1H:75C:
Length = 2.00 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 10843.8 kgf phiVn = 55270.1 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E21 (LC 119)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.418% (11.6.2) OK
Segment SC1H:75A:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK
Segment SC1H:75B:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK
Segment SC1H:75C:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 1 (11.7.2.3) OK

D79
Foundation Model Data
RAM Foundation v16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24

CONTINUOUS FOOTINGS GEOMETRY


Length (m) Width (Abs) (m)
Footing # Location (m) L1 L2 W1 W2 Thickness (m)
3 ( 0.10, 4.55) to ( 2.60, 4.55) 1.30(Abs) 1.30(Abs) 1.50 1.50 0.50(Abs)
6 ( 2.60, 0.95) to ( 2.60, 4.55) 0.70(Abs) 0.50(Abs) 1.05 1.05 0.50(Abs)
1 ( 0.10, 0.95) to ( 0.10, 4.55) 0.70(Abs) 0.50(Abs) 1.05 1.05 0.50(Abs)
4 ( 0.70, 0.10) to ( 2.00, 0.10) 0.30(Abs) 0.30(Abs) 0.85 0.85 0.50(Abs)
5 ( 2.00, 0.10) to ( 2.60, 0.95) 3.00(Max) 3.00(Max) 0.75 0.75 0.65(Max)
2 ( 0.10, 0.95) to ( 0.70, 0.10) 3.00(Max) 3.00(Max) 0.75 0.75 0.65(Max)

CONTINUOUS FOOTINGS MATERIAL PROPERTIES


Concrete Reinf. Soil Cap.(kg/m2)
Footing # f'c fct Density Type E fy or Table
(kg/cm2) (kg/cm2) (kg/m3) (kg/cm2) (kg/cm2)
3 281.23 CODE 2322.68 NW CODE 4218.46 11999.98
6 281.23 CODE 2322.68 NW CODE 4218.46 11999.98
1 281.23 CODE 2322.68 NW CODE 4218.46 11999.98
4 281.23 CODE 2322.68 NW CODE 4218.46 11999.98
5 281.23 CODE 2322.68 NW CODE 4218.46 11999.98
2 281.23 CODE 2322.68 NW CODE 4218.47 11999.98

CONTINUOUS FOOTINGS SUPPORTED MEMBERS


Column Base Plate(mm) Wall Location (m)
Footing # Location (m) Size Angle Length Width i End j End
3 (0.10, 4.55) 2499.99x200.00 0.00 N/A N/A 0.10- 4.55 4.55- 2.60
6 (2' - B) 400X400 0.00 N/A N/A
(2.60, 0.95) 3599.99x200.00 90.00 N/A N/A 2.60- 0.95 0.95- 2.60
1 (1' - B) 400X400 0.00 N/A N/A
(0.10, 0.95) 3599.99x200.00 90.00 N/A N/A 0.10- 0.95 0.95- 0.10
4 (0.70, 0.10) 1300.00x200.00 0.00 N/A N/A 0.70- 0.10 0.10- 2.00
5 (2.00, 0.10) 1040.43x200.00 54.78 N/A N/A 2.00- 0.10 0.10- 2.60
(2' - B) 400X400 0.00 N/A N/A
2 (1' - B) 400X400 0.00 N/A N/A
(0.10, 0.95) 1040.43x200.00 -54.78 N/A N/A 0.10- 0.95 0.95- 0.70

D80
Foundation Design Criteria
RAM Foundation v16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24

REINFORCEMENT PROPERTIES TABLE: ramgb50010

CODE
ACI318-14
Check ACI 318-14 Sec 13.3.3.3.b (Center Strip Reinforcement)

FORCES
Forces in Gravity Members are Material Specific.
Forces on Gravity Steel members and Gravity 'Other' columns are from RAM Steel.
Forces on Gravity Concrete members and Gravity 'Other' walls are from RAM Concrete.

DESIGN METHOD
Footings designed based on soil capacity.
Design Pile Caps Based on Pile Load.

DESIGN OPTIONS
Include Moment Due to Shear in Column for Spread Footings True
Include Moment Due to Shear in Column for Continuous Footings True
Include Moment Due to Shear in Column for Pile Caps True
Include Spread Footing Self-Weight When Checking Soil Stress True
Keep Spread Footing Square During Optimization True
Increase Spread Footing Size to Prevent Uplift in Concrete Load Combinations True
Max Width to Depth Ratio for Design of Continuous Footing as Beam Not Defined

REINFORCEMENT
Clear Bar Spacing-Shear (mm) Max: CODE Min: CODE
Clear Bar Spacing-Flexure Max: CODE Min: CODE
(mm)
Reinforcement Ratio Max: CODE Min: CODE
Clear Bar Cover (mm) Top: CODE Bottom: CODE Side: CODE
Bar Sizes Considered - Shear: #20
Bar Sizes Considered - Flexure: #20

REINFORCEMENT SELECTION
Min. number of bars in footing 5
Keep all bars in spread footing layer the same True
Adjacent bars in continuous footing may differ in size by 0
Segment Spacing Increment (mm) 50.00
Shear Bar Spacing Increment (mm) 25.00
Selection Method Min reinf area
For Square Spread Footings Keep Same Quantity and Size Bars for Layer False

D81
Foundation Design Criteria
RAM Foundation v16.00.00.28 Page 2/2
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24

OPTIMIZATION CRITERIA - SPREAD/CONTINUOUS


Min. Dimensions Edge of Base Plate to Edge of Footing (mm) 300.00
Min. Plan Dimensions (mm) 300.00
Pan Dimension Increment (mm) 100.00
Min. Thickness (mm) 500.00
Thickness Increment (mm) 25.00
Uplift Safety Factor Minimum Ratio 1.00

OPTIMIZATION CRITERIA - PILE/PILE CAP


Edge to Center of Pile Spacing is Maximum of:
Multiple of Pile Dimension 0.00
Edge to Center Distance (mm) 533.40
Clear from Face of Pile (mm) 228.60
Center to Center Spacing of Piles is Maximum of:
Multiple of Pile Dimension 3.00
Center to Center Distance (mm) 914.40
Clear from Face of Pile (mm) 609.60
Min. Thickness (mm) 762.00
Thickness Increment (mm) 76.20

PILE DEFINITIONS
Capacity
Label Diameter (mm) Compression (kgf) Tension (kgf) Shear (kgf)

PILE CONFIGURATION
Rows Parallel to
Label Major Minor
3 Pile Group 3 0
5 Pile Group 5 0
7 Pile Group 7 0
8 Pile Group 8 0
2 Pile Group 2 1
5 Pile Group Sqr. Cap 5 0

SOIL DEFINITIONS
Fixed Capacities (kg/m2) : 7332.15 ; 14563.83 ; 20590.22 ; 12260.75 ; 12052.78 ; 20088.01 ;
15000.02 ; 11999.98

D82
Load Combinations
RAM Foundation v16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24

LOAD CASE DEFINITIONS:


D Dead Load RAMUSER
Lp Live Load RAMUSER
Rfp Live Load Roof RAMUSER
E1 EQ EQ_ASCE710_X_+E_F
E2 EQ EQ_ASCE710_X_-E_F
E3 EQ EQ_ASCE710_Y_+E_F
E4 EQ EQ_ASCE710_Y_-E_F
E5 EQ EQ_ASCE710_X_+E_0.3Y_+E_
F
E6 EQ EQ_ASCE710_X_+E_-0.3Y_+E_
F
E7 EQ EQ_ASCE710_-X_+E_0.3Y_+E_
F
E8 EQ EQ_ASCE710_-X_+E_-0.3Y_+E
_F
E9 EQ EQ_ASCE710_0.3X_+E_Y_+E_
F
E10 EQ EQ_ASCE710_0.3X_+E_-Y_+E_
F
E11 EQ EQ_ASCE710_-0.3X_+E_Y_+E_
F
E12 EQ EQ_ASCE710_-0.3X_+E_-Y_+E
_F
E13 EQ EQ_ASCE710_X_+E_0.3Y_-E_F
E14 EQ EQ_ASCE710_X_+E_-0.3Y_-E_
F
E15 EQ EQ_ASCE710_-X_+E_0.3Y_-E_
F
E16 EQ EQ_ASCE710_-X_+E_-0.3Y_-E_
F
E17 EQ EQ_ASCE710_0.3X_+E_Y_-E_F
E18 EQ EQ_ASCE710_0.3X_+E_-Y_-E_
F
E19 EQ EQ_ASCE710_-0.3X_+E_Y_-E_
F
E20 EQ EQ_ASCE710_-0.3X_+E_-Y_-E_
F
E21 EQ EQ_ASCE710_X_-E_0.3Y_+E_F
E22 EQ EQ_ASCE710_X_-E_-0.3Y_+E_
F
E23 EQ EQ_ASCE710_-X_-E_0.3Y_+E_
F
E24 EQ EQ_ASCE710_-X_-E_-0.3Y_+E_
F
E25 EQ D83
EQ_ASCE710_0.3X_-E_Y_+E_F
Load Combinations
RAM Foundation v16.00.00.28 Page 2/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
E26 EQ EQ_ASCE710_0.3X_-E_-Y_+E_
F
E27 EQ EQ_ASCE710_-0.3X_-E_Y_+E_
F
E28 EQ EQ_ASCE710_-0.3X_-E_-Y_+E_
F
E29 EQ EQ_ASCE710_X_-E_0.3Y_-E_F
E30 EQ EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 EQ EQ_ASCE710_-X_-E_0.3Y_-E_F
E32 EQ EQ_ASCE710_-X_-E_-0.3Y_-E_
F
E33 EQ EQ_ASCE710_0.3X_-E_Y_-E_F
E34 EQ EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 EQ EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 EQ EQ_ASCE710_-0.3X_-E_-Y_-E_
F
W1 WL Wind_ASCE710_1_X
W2 WL Wind_ASCE710_1_Y
W3 WL Wind_ASCE710_2_X+E
W4 WL Wind_ASCE710_2_X-E
W5 WL Wind_ASCE710_2_Y+E
W6 WL Wind_ASCE710_2_Y-E
W7 WL Wind_ASCE710_3_X+Y
W8 WL Wind_ASCE710_3_X-Y
W9 WL Wind_ASCE710_4_X+Y_CW
W10 WL Wind_ASCE710_4_X+Y_CCW
W11 WL Wind_ASCE710_4_X-Y_CW
W12 WL Wind_ASCE710_4_X-Y_CCW

CONCRETE COMBINATION CRITERIA:


Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Reducible
Live Load factor f1 (0.5 or 0.500
1.0)
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300
GENERATED CONCRETE LOAD COMBINATIONS:
1 * 1.400 D
2 * 1.200 D + 1.600 Lp + 0.500 Rfp
3 * 1.200 D + 1.600 Lp
4 * 1.200 D + 0.500 Lp + 1.600 Rfp
5 * 1.200 D + 1.600 Rfp
6 * 1.200 D + 1.600 Rfp + 0.500 W1
7 * 1.200 D + 1.600 Rfp + 0.500 W2
D84
Load Combinations
RAM Foundation v16.00.00.28 Page 3/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
8 * 1.200 D + 1.600 Rfp + 0.500 W3
9 * 1.200 D + 1.600 Rfp + 0.500 W4
10 * 1.200 D + 1.600 Rfp + 0.500 W5
11 * 1.200 D + 1.600 Rfp + 0.500 W6
12 * 1.200 D + 1.600 Rfp + 0.500 W7
13 * 1.200 D + 1.600 Rfp + 0.500 W8
14 * 1.200 D + 1.600 Rfp + 0.500 W9
15 * 1.200 D + 1.600 Rfp + 0.500 W10
16 * 1.200 D + 1.600 Rfp + 0.500 W11
17 * 1.200 D + 1.600 Rfp + 0.500 W12
18 * 1.200 D + 1.600 Rfp - 0.500 W1
19 * 1.200 D + 1.600 Rfp - 0.500 W2
20 * 1.200 D + 1.600 Rfp - 0.500 W3
21 * 1.200 D + 1.600 Rfp - 0.500 W4
22 * 1.200 D + 1.600 Rfp - 0.500 W5
23 * 1.200 D + 1.600 Rfp - 0.500 W6
24 * 1.200 D + 1.600 Rfp - 0.500 W7
25 * 1.200 D + 1.600 Rfp - 0.500 W8
26 * 1.200 D + 1.600 Rfp - 0.500 W9
27 * 1.200 D + 1.600 Rfp - 0.500 W10
28 * 1.200 D + 1.600 Rfp - 0.500 W11
29 * 1.200 D + 1.600 Rfp - 0.500 W12
30 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W1
31 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W2
32 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W3
33 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W4
34 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W5
35 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W6
36 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W7
37 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W8
38 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W9
39 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W10
40 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W11
41 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W12
42 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W1
43 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W2
44 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W3
45 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W4
46 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W5
47 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W6
48 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W7
49 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W8
50 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W9
51 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W10
52 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W11
53 * 1.200 D + 0.500 Lp + 0.500
D85Rfp - 1.000 W12
Load Combinations
RAM Foundation v16.00.00.28 Page 4/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
54 * 1.200 D + 0.500 Lp + 1.000 W1
55 * 1.200 D + 0.500 Lp + 1.000 W2
56 * 1.200 D + 0.500 Lp + 1.000 W3
57 * 1.200 D + 0.500 Lp + 1.000 W4
58 * 1.200 D + 0.500 Lp + 1.000 W5
59 * 1.200 D + 0.500 Lp + 1.000 W6
60 * 1.200 D + 0.500 Lp + 1.000 W7
61 * 1.200 D + 0.500 Lp + 1.000 W8
62 * 1.200 D + 0.500 Lp + 1.000 W9
63 * 1.200 D + 0.500 Lp + 1.000 W10
64 * 1.200 D + 0.500 Lp + 1.000 W11
65 * 1.200 D + 0.500 Lp + 1.000 W12
66 * 1.200 D + 0.500 Lp - 1.000 W1
67 * 1.200 D + 0.500 Lp - 1.000 W2
68 * 1.200 D + 0.500 Lp - 1.000 W3
69 * 1.200 D + 0.500 Lp - 1.000 W4
70 * 1.200 D + 0.500 Lp - 1.000 W5
71 * 1.200 D + 0.500 Lp - 1.000 W6
72 * 1.200 D + 0.500 Lp - 1.000 W7
73 * 1.200 D + 0.500 Lp - 1.000 W8
74 * 1.200 D + 0.500 Lp - 1.000 W9
75 * 1.200 D + 0.500 Lp - 1.000 W10
76 * 1.200 D + 0.500 Lp - 1.000 W11
77 * 1.200 D + 0.500 Lp - 1.000 W12
78 * 1.200 D + 0.500 Rfp + 1.000 W1
79 * 1.200 D + 0.500 Rfp + 1.000 W2
80 * 1.200 D + 0.500 Rfp + 1.000 W3
81 * 1.200 D + 0.500 Rfp + 1.000 W4
82 * 1.200 D + 0.500 Rfp + 1.000 W5
83 * 1.200 D + 0.500 Rfp + 1.000 W6
84 * 1.200 D + 0.500 Rfp + 1.000 W7
85 * 1.200 D + 0.500 Rfp + 1.000 W8
86 * 1.200 D + 0.500 Rfp + 1.000 W9
87 * 1.200 D + 0.500 Rfp + 1.000 W10
88 * 1.200 D + 0.500 Rfp + 1.000 W11
89 * 1.200 D + 0.500 Rfp + 1.000 W12
90 * 1.200 D + 0.500 Rfp - 1.000 W1
91 * 1.200 D + 0.500 Rfp - 1.000 W2
92 * 1.200 D + 0.500 Rfp - 1.000 W3
93 * 1.200 D + 0.500 Rfp - 1.000 W4
94 * 1.200 D + 0.500 Rfp - 1.000 W5
95 * 1.200 D + 0.500 Rfp - 1.000 W6
96 * 1.200 D + 0.500 Rfp - 1.000 W7
97 * 1.200 D + 0.500 Rfp - 1.000 W8
98 * 1.200 D + 0.500 Rfp - 1.000 W9
99 * 1.200 D + 0.500 Rfp - 1.000
D86 W10
Load Combinations
RAM Foundation v16.00.00.28 Page 5/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
100 * 1.200 D + 0.500 Rfp - 1.000 W11
101 * 1.200 D + 0.500 Rfp - 1.000 W12
102 * 1.200 D + 1.000 W1
103 * 1.200 D + 1.000 W2
104 * 1.200 D + 1.000 W3
105 * 1.200 D + 1.000 W4
106 * 1.200 D + 1.000 W5
107 * 1.200 D + 1.000 W6
108 * 1.200 D + 1.000 W7
109 * 1.200 D + 1.000 W8
110 * 1.200 D + 1.000 W9
111 * 1.200 D + 1.000 W10
112 * 1.200 D + 1.000 W11
113 * 1.200 D + 1.000 W12
114 * 1.200 D - 1.000 W1
115 * 1.200 D - 1.000 W2
116 * 1.200 D - 1.000 W3
117 * 1.200 D - 1.000 W4
118 * 1.200 D - 1.000 W5
119 * 1.200 D - 1.000 W6
120 * 1.200 D - 1.000 W7
121 * 1.200 D - 1.000 W8
122 * 1.200 D - 1.000 W9
123 * 1.200 D - 1.000 W10
124 * 1.200 D - 1.000 W11
125 * 1.200 D - 1.000 W12
126 * 0.900 D + 1.000 W1
127 * 0.900 D + 1.000 W2
128 * 0.900 D + 1.000 W3
129 * 0.900 D + 1.000 W4
130 * 0.900 D + 1.000 W5
131 * 0.900 D + 1.000 W6
132 * 0.900 D + 1.000 W7
133 * 0.900 D + 1.000 W8
134 * 0.900 D + 1.000 W9
135 * 0.900 D + 1.000 W10
136 * 0.900 D + 1.000 W11
137 * 0.900 D + 1.000 W12
138 * 0.900 D - 1.000 W1
139 * 0.900 D - 1.000 W2
140 * 0.900 D - 1.000 W3
141 * 0.900 D - 1.000 W4
142 * 0.900 D - 1.000 W5
143 * 0.900 D - 1.000 W6
144 * 0.900 D - 1.000 W7
145 * 0.900 D - 1.000 W8 D87
Load Combinations
RAM Foundation v16.00.00.28 Page 6/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
146 * 0.900 D - 1.000 W9
147 * 0.900 D - 1.000 W10
148 * 0.900 D - 1.000 W11
149 * 0.900 D - 1.000 W12
150 * 1.274 D + 0.500 Lp + 1.300 E1
151 * 1.274 D + 0.500 Lp + 1.300 E2
152 * 1.274 D + 0.500 Lp + 1.300 E3
153 * 1.274 D + 0.500 Lp + 1.300 E4
154 * 1.274 D + 0.500 Lp + 1.300 E5
155 * 1.274 D + 0.500 Lp + 1.300 E6
156 * 1.274 D + 0.500 Lp + 1.300 E7
157 * 1.274 D + 0.500 Lp + 1.300 E8
158 * 1.274 D + 0.500 Lp + 1.300 E9
159 * 1.274 D + 0.500 Lp + 1.300 E10
160 * 1.274 D + 0.500 Lp + 1.300 E11
161 * 1.274 D + 0.500 Lp + 1.300 E12
162 * 1.274 D + 0.500 Lp + 1.300 E13
163 * 1.274 D + 0.500 Lp + 1.300 E14
164 * 1.274 D + 0.500 Lp + 1.300 E15
165 * 1.274 D + 0.500 Lp + 1.300 E16
166 * 1.274 D + 0.500 Lp + 1.300 E17
167 * 1.274 D + 0.500 Lp + 1.300 E18
168 * 1.274 D + 0.500 Lp + 1.300 E19
169 * 1.274 D + 0.500 Lp + 1.300 E20
170 * 1.274 D + 0.500 Lp + 1.300 E21
171 * 1.274 D + 0.500 Lp + 1.300 E22
172 * 1.274 D + 0.500 Lp + 1.300 E23
173 * 1.274 D + 0.500 Lp + 1.300 E24
174 * 1.274 D + 0.500 Lp + 1.300 E25
175 * 1.274 D + 0.500 Lp + 1.300 E26
176 * 1.274 D + 0.500 Lp + 1.300 E27
177 * 1.274 D + 0.500 Lp + 1.300 E28
178 * 1.274 D + 0.500 Lp + 1.300 E29
179 * 1.274 D + 0.500 Lp + 1.300 E30
180 * 1.274 D + 0.500 Lp + 1.300 E31
181 * 1.274 D + 0.500 Lp + 1.300 E32
182 * 1.274 D + 0.500 Lp + 1.300 E33
183 * 1.274 D + 0.500 Lp + 1.300 E34
184 * 1.274 D + 0.500 Lp + 1.300 E35
185 * 1.274 D + 0.500 Lp + 1.300 E36
186 * 1.274 D + 0.500 Lp - 1.300 E1
187 * 1.274 D + 0.500 Lp - 1.300 E2
188 * 1.274 D + 0.500 Lp - 1.300 E3
189 * 1.274 D + 0.500 Lp - 1.300 E4
190 * 1.274 D + 0.500 Lp - 1.300 E5
191 * 1.274 D + 0.500 Lp - 1.300
D88E6
Load Combinations
RAM Foundation v16.00.00.28 Page 7/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
192 * 1.274 D + 0.500 Lp - 1.300 E7
193 * 1.274 D + 0.500 Lp - 1.300 E8
194 * 1.274 D + 0.500 Lp - 1.300 E9
195 * 1.274 D + 0.500 Lp - 1.300 E10
196 * 1.274 D + 0.500 Lp - 1.300 E11
197 * 1.274 D + 0.500 Lp - 1.300 E12
198 * 1.274 D + 0.500 Lp - 1.300 E13
199 * 1.274 D + 0.500 Lp - 1.300 E14
200 * 1.274 D + 0.500 Lp - 1.300 E15
201 * 1.274 D + 0.500 Lp - 1.300 E16
202 * 1.274 D + 0.500 Lp - 1.300 E17
203 * 1.274 D + 0.500 Lp - 1.300 E18
204 * 1.274 D + 0.500 Lp - 1.300 E19
205 * 1.274 D + 0.500 Lp - 1.300 E20
206 * 1.274 D + 0.500 Lp - 1.300 E21
207 * 1.274 D + 0.500 Lp - 1.300 E22
208 * 1.274 D + 0.500 Lp - 1.300 E23
209 * 1.274 D + 0.500 Lp - 1.300 E24
210 * 1.274 D + 0.500 Lp - 1.300 E25
211 * 1.274 D + 0.500 Lp - 1.300 E26
212 * 1.274 D + 0.500 Lp - 1.300 E27
213 * 1.274 D + 0.500 Lp - 1.300 E28
214 * 1.274 D + 0.500 Lp - 1.300 E29
215 * 1.274 D + 0.500 Lp - 1.300 E30
216 * 1.274 D + 0.500 Lp - 1.300 E31
217 * 1.274 D + 0.500 Lp - 1.300 E32
218 * 1.274 D + 0.500 Lp - 1.300 E33
219 * 1.274 D + 0.500 Lp - 1.300 E34
220 * 1.274 D + 0.500 Lp - 1.300 E35
221 * 1.274 D + 0.500 Lp - 1.300 E36
222 * 1.274 D + 1.300 E1
223 * 1.274 D + 1.300 E2
224 * 1.274 D + 1.300 E3
225 * 1.274 D + 1.300 E4
226 * 1.274 D + 1.300 E5
227 * 1.274 D + 1.300 E6
228 * 1.274 D + 1.300 E7
229 * 1.274 D + 1.300 E8
230 * 1.274 D + 1.300 E9
231 * 1.274 D + 1.300 E10
232 * 1.274 D + 1.300 E11
233 * 1.274 D + 1.300 E12
234 * 1.274 D + 1.300 E13
235 * 1.274 D + 1.300 E14
236 * 1.274 D + 1.300 E15
237 * 1.274 D + 1.300 E16 D89
Load Combinations
RAM Foundation v16.00.00.28 Page 8/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
238 * 1.274 D + 1.300 E17
239 * 1.274 D + 1.300 E18
240 * 1.274 D + 1.300 E19
241 * 1.274 D + 1.300 E20
242 * 1.274 D + 1.300 E21
243 * 1.274 D + 1.300 E22
244 * 1.274 D + 1.300 E23
245 * 1.274 D + 1.300 E24
246 * 1.274 D + 1.300 E25
247 * 1.274 D + 1.300 E26
248 * 1.274 D + 1.300 E27
249 * 1.274 D + 1.300 E28
250 * 1.274 D + 1.300 E29
251 * 1.274 D + 1.300 E30
252 * 1.274 D + 1.300 E31
253 * 1.274 D + 1.300 E32
254 * 1.274 D + 1.300 E33
255 * 1.274 D + 1.300 E34
256 * 1.274 D + 1.300 E35
257 * 1.274 D + 1.300 E36
258 * 1.274 D - 1.300 E1
259 * 1.274 D - 1.300 E2
260 * 1.274 D - 1.300 E3
261 * 1.274 D - 1.300 E4
262 * 1.274 D - 1.300 E5
263 * 1.274 D - 1.300 E6
264 * 1.274 D - 1.300 E7
265 * 1.274 D - 1.300 E8
266 * 1.274 D - 1.300 E9
267 * 1.274 D - 1.300 E10
268 * 1.274 D - 1.300 E11
269 * 1.274 D - 1.300 E12
270 * 1.274 D - 1.300 E13
271 * 1.274 D - 1.300 E14
272 * 1.274 D - 1.300 E15
273 * 1.274 D - 1.300 E16
274 * 1.274 D - 1.300 E17
275 * 1.274 D - 1.300 E18
276 * 1.274 D - 1.300 E19
277 * 1.274 D - 1.300 E20
278 * 1.274 D - 1.300 E21
279 * 1.274 D - 1.300 E22
280 * 1.274 D - 1.300 E23
281 * 1.274 D - 1.300 E24
282 * 1.274 D - 1.300 E25
283 * 1.274 D - 1.300 E26 D90
Load Combinations
RAM Foundation v16.00.00.28 Page 9/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
284 * 1.274 D - 1.300 E27
285 * 1.274 D - 1.300 E28
286 * 1.274 D - 1.300 E29
287 * 1.274 D - 1.300 E30
288 * 1.274 D - 1.300 E31
289 * 1.274 D - 1.300 E32
290 * 1.274 D - 1.300 E33
291 * 1.274 D - 1.300 E34
292 * 1.274 D - 1.300 E35
293 * 1.274 D - 1.300 E36
294 * 0.826 D + 1.300 E1
295 * 0.826 D + 1.300 E2
296 * 0.826 D + 1.300 E3
297 * 0.826 D + 1.300 E4
298 * 0.826 D + 1.300 E5
299 * 0.826 D + 1.300 E6
300 * 0.826 D + 1.300 E7
301 * 0.826 D + 1.300 E8
302 * 0.826 D + 1.300 E9
303 * 0.826 D + 1.300 E10
304 * 0.826 D + 1.300 E11
305 * 0.826 D + 1.300 E12
306 * 0.826 D + 1.300 E13
307 * 0.826 D + 1.300 E14
308 * 0.826 D + 1.300 E15
309 * 0.826 D + 1.300 E16
310 * 0.826 D + 1.300 E17
311 * 0.826 D + 1.300 E18
312 * 0.826 D + 1.300 E19
313 * 0.826 D + 1.300 E20
314 * 0.826 D + 1.300 E21
315 * 0.826 D + 1.300 E22
316 * 0.826 D + 1.300 E23
317 * 0.826 D + 1.300 E24
318 * 0.826 D + 1.300 E25
319 * 0.826 D + 1.300 E26
320 * 0.826 D + 1.300 E27
321 * 0.826 D + 1.300 E28
322 * 0.826 D + 1.300 E29
323 * 0.826 D + 1.300 E30
324 * 0.826 D + 1.300 E31
325 * 0.826 D + 1.300 E32
326 * 0.826 D + 1.300 E33
327 * 0.826 D + 1.300 E34
328 * 0.826 D + 1.300 E35
329 * 0.826 D + 1.300 E36 D91
Load Combinations
RAM Foundation v16.00.00.28 Page 10/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
330 * 0.826 D - 1.300 E1
331 * 0.826 D - 1.300 E2
332 * 0.826 D - 1.300 E3
333 * 0.826 D - 1.300 E4
334 * 0.826 D - 1.300 E5
335 * 0.826 D - 1.300 E6
336 * 0.826 D - 1.300 E7
337 * 0.826 D - 1.300 E8
338 * 0.826 D - 1.300 E9
339 * 0.826 D - 1.300 E10
340 * 0.826 D - 1.300 E11
341 * 0.826 D - 1.300 E12
342 * 0.826 D - 1.300 E13
343 * 0.826 D - 1.300 E14
344 * 0.826 D - 1.300 E15
345 * 0.826 D - 1.300 E16
346 * 0.826 D - 1.300 E17
347 * 0.826 D - 1.300 E18
348 * 0.826 D - 1.300 E19
349 * 0.826 D - 1.300 E20
350 * 0.826 D - 1.300 E21
351 * 0.826 D - 1.300 E22
352 * 0.826 D - 1.300 E23
353 * 0.826 D - 1.300 E24
354 * 0.826 D - 1.300 E25
355 * 0.826 D - 1.300 E26
356 * 0.826 D - 1.300 E27
357 * 0.826 D - 1.300 E28
358 * 0.826 D - 1.300 E29
359 * 0.826 D - 1.300 E30
360 * 0.826 D - 1.300 E31
361 * 0.826 D - 1.300 E32
362 * 0.826 D - 1.300 E33
363 * 0.826 D - 1.300 E34
364 * 0.826 D - 1.300 E35
365 * 0.826 D - 1.300 E36

SOIL COMBINATION CRITERIA:


Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Reducible
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300
GENERATED SOIL LOAD COMBINATIONS:
366 * 1.000 D
D92
Load Combinations
RAM Foundation v16.00.00.28 Page 11/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
367 * 1.000 D + 1.000 Lp
368 * 1.000 D + 1.000 Rfp
369 * 1.000 D + 0.750 Lp + 0.750 Rfp
370 * 1.000 D + 0.600 W1
371 * 1.000 D + 0.600 W2
372 * 1.000 D + 0.600 W3
373 * 1.000 D + 0.600 W4
374 * 1.000 D + 0.600 W5
375 * 1.000 D + 0.600 W6
376 * 1.000 D + 0.600 W7
377 * 1.000 D + 0.600 W8
378 * 1.000 D + 0.600 W9
379 * 1.000 D + 0.600 W10
380 * 1.000 D + 0.600 W11
381 * 1.000 D + 0.600 W12
382 * 1.000 D - 0.600 W1
383 * 1.000 D - 0.600 W2
384 * 1.000 D - 0.600 W3
385 * 1.000 D - 0.600 W4
386 * 1.000 D - 0.600 W5
387 * 1.000 D - 0.600 W6
388 * 1.000 D - 0.600 W7
389 * 1.000 D - 0.600 W8
390 * 1.000 D - 0.600 W9
391 * 1.000 D - 0.600 W10
392 * 1.000 D - 0.600 W11
393 * 1.000 D - 0.600 W12
394 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W1
395 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W2
396 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W3
397 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W4
398 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W5
399 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W6
400 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W7
401 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W8
402 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W9
403 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W10
404 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W11
405 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W12
406 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W1
407 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W2
408 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W3
409 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W4
410 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W5
411 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W6
412 * 1.000 D + 0.750 Lp + 0.750
D93Rfp - 0.450 W7
Load Combinations
RAM Foundation v16.00.00.28 Page 12/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
413 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W8
414 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W9
415 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W10
416 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W11
417 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W12
418 * 1.000 D + 0.750 Lp + 0.450 W1
419 * 1.000 D + 0.750 Lp + 0.450 W2
420 * 1.000 D + 0.750 Lp + 0.450 W3
421 * 1.000 D + 0.750 Lp + 0.450 W4
422 * 1.000 D + 0.750 Lp + 0.450 W5
423 * 1.000 D + 0.750 Lp + 0.450 W6
424 * 1.000 D + 0.750 Lp + 0.450 W7
425 * 1.000 D + 0.750 Lp + 0.450 W8
426 * 1.000 D + 0.750 Lp + 0.450 W9
427 * 1.000 D + 0.750 Lp + 0.450 W10
428 * 1.000 D + 0.750 Lp + 0.450 W11
429 * 1.000 D + 0.750 Lp + 0.450 W12
430 * 1.000 D + 0.750 Lp - 0.450 W1
431 * 1.000 D + 0.750 Lp - 0.450 W2
432 * 1.000 D + 0.750 Lp - 0.450 W3
433 * 1.000 D + 0.750 Lp - 0.450 W4
434 * 1.000 D + 0.750 Lp - 0.450 W5
435 * 1.000 D + 0.750 Lp - 0.450 W6
436 * 1.000 D + 0.750 Lp - 0.450 W7
437 * 1.000 D + 0.750 Lp - 0.450 W8
438 * 1.000 D + 0.750 Lp - 0.450 W9
439 * 1.000 D + 0.750 Lp - 0.450 W10
440 * 1.000 D + 0.750 Lp - 0.450 W11
441 * 1.000 D + 0.750 Lp - 0.450 W12
442 * 1.000 D + 0.750 Rfp + 0.450 W1
443 * 1.000 D + 0.750 Rfp + 0.450 W2
444 * 1.000 D + 0.750 Rfp + 0.450 W3
445 * 1.000 D + 0.750 Rfp + 0.450 W4
446 * 1.000 D + 0.750 Rfp + 0.450 W5
447 * 1.000 D + 0.750 Rfp + 0.450 W6
448 * 1.000 D + 0.750 Rfp + 0.450 W7
449 * 1.000 D + 0.750 Rfp + 0.450 W8
450 * 1.000 D + 0.750 Rfp + 0.450 W9
451 * 1.000 D + 0.750 Rfp + 0.450 W10
452 * 1.000 D + 0.750 Rfp + 0.450 W11
453 * 1.000 D + 0.750 Rfp + 0.450 W12
454 * 1.000 D + 0.750 Rfp - 0.450 W1
455 * 1.000 D + 0.750 Rfp - 0.450 W2
456 * 1.000 D + 0.750 Rfp - 0.450 W3
457 * 1.000 D + 0.750 Rfp - 0.450 W4
458 * 1.000 D + 0.750 Rfp - 0.450
D94 W5
Load Combinations
RAM Foundation v16.00.00.28 Page 13/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
459 * 1.000 D + 0.750 Rfp - 0.450 W6
460 * 1.000 D + 0.750 Rfp - 0.450 W7
461 * 1.000 D + 0.750 Rfp - 0.450 W8
462 * 1.000 D + 0.750 Rfp - 0.450 W9
463 * 1.000 D + 0.750 Rfp - 0.450 W10
464 * 1.000 D + 0.750 Rfp - 0.450 W11
465 * 1.000 D + 0.750 Rfp - 0.450 W12
466 * 0.600 D + 0.600 W1
467 * 0.600 D + 0.600 W2
468 * 0.600 D + 0.600 W3
469 * 0.600 D + 0.600 W4
470 * 0.600 D + 0.600 W5
471 * 0.600 D + 0.600 W6
472 * 0.600 D + 0.600 W7
473 * 0.600 D + 0.600 W8
474 * 0.600 D + 0.600 W9
475 * 0.600 D + 0.600 W10
476 * 0.600 D + 0.600 W11
477 * 0.600 D + 0.600 W12
478 * 0.600 D - 0.600 W1
479 * 0.600 D - 0.600 W2
480 * 0.600 D - 0.600 W3
481 * 0.600 D - 0.600 W4
482 * 0.600 D - 0.600 W5
483 * 0.600 D - 0.600 W6
484 * 0.600 D - 0.600 W7
485 * 0.600 D - 0.600 W8
486 * 0.600 D - 0.600 W9
487 * 0.600 D - 0.600 W10
488 * 0.600 D - 0.600 W11
489 * 0.600 D - 0.600 W12
490 * 1.052 D + 0.910 E1
491 * 1.052 D + 0.910 E2
492 * 1.052 D + 0.910 E3
493 * 1.052 D + 0.910 E4
494 * 1.052 D + 0.910 E5
495 * 1.052 D + 0.910 E6
496 * 1.052 D + 0.910 E7
497 * 1.052 D + 0.910 E8
498 * 1.052 D + 0.910 E9
499 * 1.052 D + 0.910 E10
500 * 1.052 D + 0.910 E11
501 * 1.052 D + 0.910 E12
502 * 1.052 D + 0.910 E13
503 * 1.052 D + 0.910 E14
504 * 1.052 D + 0.910 E15 D95
Load Combinations
RAM Foundation v16.00.00.28 Page 14/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
505 * 1.052 D + 0.910 E16
506 * 1.052 D + 0.910 E17
507 * 1.052 D + 0.910 E18
508 * 1.052 D + 0.910 E19
509 * 1.052 D + 0.910 E20
510 * 1.052 D + 0.910 E21
511 * 1.052 D + 0.910 E22
512 * 1.052 D + 0.910 E23
513 * 1.052 D + 0.910 E24
514 * 1.052 D + 0.910 E25
515 * 1.052 D + 0.910 E26
516 * 1.052 D + 0.910 E27
517 * 1.052 D + 0.910 E28
518 * 1.052 D + 0.910 E29
519 * 1.052 D + 0.910 E30
520 * 1.052 D + 0.910 E31
521 * 1.052 D + 0.910 E32
522 * 1.052 D + 0.910 E33
523 * 1.052 D + 0.910 E34
524 * 1.052 D + 0.910 E35
525 * 1.052 D + 0.910 E36
526 * 1.052 D - 0.910 E1
527 * 1.052 D - 0.910 E2
528 * 1.052 D - 0.910 E3
529 * 1.052 D - 0.910 E4
530 * 1.052 D - 0.910 E5
531 * 1.052 D - 0.910 E6
532 * 1.052 D - 0.910 E7
533 * 1.052 D - 0.910 E8
534 * 1.052 D - 0.910 E9
535 * 1.052 D - 0.910 E10
536 * 1.052 D - 0.910 E11
537 * 1.052 D - 0.910 E12
538 * 1.052 D - 0.910 E13
539 * 1.052 D - 0.910 E14
540 * 1.052 D - 0.910 E15
541 * 1.052 D - 0.910 E16
542 * 1.052 D - 0.910 E17
543 * 1.052 D - 0.910 E18
544 * 1.052 D - 0.910 E19
545 * 1.052 D - 0.910 E20
546 * 1.052 D - 0.910 E21
547 * 1.052 D - 0.910 E22
548 * 1.052 D - 0.910 E23
549 * 1.052 D - 0.910 E24
550 * 1.052 D - 0.910 E25 D96
Load Combinations
RAM Foundation v16.00.00.28 Page 15/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
551 * 1.052 D - 0.910 E26
552 * 1.052 D - 0.910 E27
553 * 1.052 D - 0.910 E28
554 * 1.052 D - 0.910 E29
555 * 1.052 D - 0.910 E30
556 * 1.052 D - 0.910 E31
557 * 1.052 D - 0.910 E32
558 * 1.052 D - 0.910 E33
559 * 1.052 D - 0.910 E34
560 * 1.052 D - 0.910 E35
561 * 1.052 D - 0.910 E36
562 * 1.039 D + 0.750 Lp + 0.683 E1
563 * 1.039 D + 0.750 Lp + 0.683 E2
564 * 1.039 D + 0.750 Lp + 0.683 E3
565 * 1.039 D + 0.750 Lp + 0.683 E4
566 * 1.039 D + 0.750 Lp + 0.683 E5
567 * 1.039 D + 0.750 Lp + 0.683 E6
568 * 1.039 D + 0.750 Lp + 0.683 E7
569 * 1.039 D + 0.750 Lp + 0.683 E8
570 * 1.039 D + 0.750 Lp + 0.683 E9
571 * 1.039 D + 0.750 Lp + 0.683 E10
572 * 1.039 D + 0.750 Lp + 0.683 E11
573 * 1.039 D + 0.750 Lp + 0.683 E12
574 * 1.039 D + 0.750 Lp + 0.683 E13
575 * 1.039 D + 0.750 Lp + 0.683 E14
576 * 1.039 D + 0.750 Lp + 0.683 E15
577 * 1.039 D + 0.750 Lp + 0.683 E16
578 * 1.039 D + 0.750 Lp + 0.683 E17
579 * 1.039 D + 0.750 Lp + 0.683 E18
580 * 1.039 D + 0.750 Lp + 0.683 E19
581 * 1.039 D + 0.750 Lp + 0.683 E20
582 * 1.039 D + 0.750 Lp + 0.683 E21
583 * 1.039 D + 0.750 Lp + 0.683 E22
584 * 1.039 D + 0.750 Lp + 0.683 E23
585 * 1.039 D + 0.750 Lp + 0.683 E24
586 * 1.039 D + 0.750 Lp + 0.683 E25
587 * 1.039 D + 0.750 Lp + 0.683 E26
588 * 1.039 D + 0.750 Lp + 0.683 E27
589 * 1.039 D + 0.750 Lp + 0.683 E28
590 * 1.039 D + 0.750 Lp + 0.683 E29
591 * 1.039 D + 0.750 Lp + 0.683 E30
592 * 1.039 D + 0.750 Lp + 0.683 E31
593 * 1.039 D + 0.750 Lp + 0.683 E32
594 * 1.039 D + 0.750 Lp + 0.683 E33
595 * 1.039 D + 0.750 Lp + 0.683 E34
596 * 1.039 D + 0.750 Lp + 0.683
D97E35
Load Combinations
RAM Foundation v16.00.00.28 Page 16/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
597 * 1.039 D + 0.750 Lp + 0.683 E36
598 * 1.039 D + 0.750 Lp - 0.683 E1
599 * 1.039 D + 0.750 Lp - 0.683 E2
600 * 1.039 D + 0.750 Lp - 0.683 E3
601 * 1.039 D + 0.750 Lp - 0.683 E4
602 * 1.039 D + 0.750 Lp - 0.683 E5
603 * 1.039 D + 0.750 Lp - 0.683 E6
604 * 1.039 D + 0.750 Lp - 0.683 E7
605 * 1.039 D + 0.750 Lp - 0.683 E8
606 * 1.039 D + 0.750 Lp - 0.683 E9
607 * 1.039 D + 0.750 Lp - 0.683 E10
608 * 1.039 D + 0.750 Lp - 0.683 E11
609 * 1.039 D + 0.750 Lp - 0.683 E12
610 * 1.039 D + 0.750 Lp - 0.683 E13
611 * 1.039 D + 0.750 Lp - 0.683 E14
612 * 1.039 D + 0.750 Lp - 0.683 E15
613 * 1.039 D + 0.750 Lp - 0.683 E16
614 * 1.039 D + 0.750 Lp - 0.683 E17
615 * 1.039 D + 0.750 Lp - 0.683 E18
616 * 1.039 D + 0.750 Lp - 0.683 E19
617 * 1.039 D + 0.750 Lp - 0.683 E20
618 * 1.039 D + 0.750 Lp - 0.683 E21
619 * 1.039 D + 0.750 Lp - 0.683 E22
620 * 1.039 D + 0.750 Lp - 0.683 E23
621 * 1.039 D + 0.750 Lp - 0.683 E24
622 * 1.039 D + 0.750 Lp - 0.683 E25
623 * 1.039 D + 0.750 Lp - 0.683 E26
624 * 1.039 D + 0.750 Lp - 0.683 E27
625 * 1.039 D + 0.750 Lp - 0.683 E28
626 * 1.039 D + 0.750 Lp - 0.683 E29
627 * 1.039 D + 0.750 Lp - 0.683 E30
628 * 1.039 D + 0.750 Lp - 0.683 E31
629 * 1.039 D + 0.750 Lp - 0.683 E32
630 * 1.039 D + 0.750 Lp - 0.683 E33
631 * 1.039 D + 0.750 Lp - 0.683 E34
632 * 1.039 D + 0.750 Lp - 0.683 E35
633 * 1.039 D + 0.750 Lp - 0.683 E36
634 * 0.600 D + 0.910 E1
635 * 0.600 D + 0.910 E2
636 * 0.600 D + 0.910 E3
637 * 0.600 D + 0.910 E4
638 * 0.600 D + 0.910 E5
639 * 0.600 D + 0.910 E6
640 * 0.600 D + 0.910 E7
641 * 0.600 D + 0.910 E8
642 * 0.600 D + 0.910 E9 D98
Load Combinations
RAM Foundation v16.00.00.28 Page 17/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
643 * 0.600 D + 0.910 E10
644 * 0.600 D + 0.910 E11
645 * 0.600 D + 0.910 E12
646 * 0.600 D + 0.910 E13
647 * 0.600 D + 0.910 E14
648 * 0.600 D + 0.910 E15
649 * 0.600 D + 0.910 E16
650 * 0.600 D + 0.910 E17
651 * 0.600 D + 0.910 E18
652 * 0.600 D + 0.910 E19
653 * 0.600 D + 0.910 E20
654 * 0.600 D + 0.910 E21
655 * 0.600 D + 0.910 E22
656 * 0.600 D + 0.910 E23
657 * 0.600 D + 0.910 E24
658 * 0.600 D + 0.910 E25
659 * 0.600 D + 0.910 E26
660 * 0.600 D + 0.910 E27
661 * 0.600 D + 0.910 E28
662 * 0.600 D + 0.910 E29
663 * 0.600 D + 0.910 E30
664 * 0.600 D + 0.910 E31
665 * 0.600 D + 0.910 E32
666 * 0.600 D + 0.910 E33
667 * 0.600 D + 0.910 E34
668 * 0.600 D + 0.910 E35
669 * 0.600 D + 0.910 E36
670 * 0.600 D - 0.910 E1
671 * 0.600 D - 0.910 E2
672 * 0.600 D - 0.910 E3
673 * 0.600 D - 0.910 E4
674 * 0.600 D - 0.910 E5
675 * 0.600 D - 0.910 E6
676 * 0.600 D - 0.910 E7
677 * 0.600 D - 0.910 E8
678 * 0.600 D - 0.910 E9
679 * 0.600 D - 0.910 E10
680 * 0.600 D - 0.910 E11
681 * 0.600 D - 0.910 E12
682 * 0.600 D - 0.910 E13
683 * 0.600 D - 0.910 E14
684 * 0.600 D - 0.910 E15
685 * 0.600 D - 0.910 E16
686 * 0.600 D - 0.910 E17
687 * 0.600 D - 0.910 E18
688 * 0.600 D - 0.910 E19 D99
Load Combinations
RAM Foundation v16.00.00.28 Page 18/18
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
689 * 0.600 D - 0.910 E20
690 * 0.600 D - 0.910 E21
691 * 0.600 D - 0.910 E22
692 * 0.600 D - 0.910 E23
693 * 0.600 D - 0.910 E24
694 * 0.600 D - 0.910 E25
695 * 0.600 D - 0.910 E26
696 * 0.600 D - 0.910 E27
697 * 0.600 D - 0.910 E28
698 * 0.600 D - 0.910 E29
699 * 0.600 D - 0.910 E30
700 * 0.600 D - 0.910 E31
701 * 0.600 D - 0.910 E32
702 * 0.600 D - 0.910 E33
703 * 0.600 D - 0.910 E34
704 * 0.600 D - 0.910 E35
705 * 0.600 D - 0.910 E36
* = Load combination currently selected to use

D100
RAM Structural System V16.00.00.28.
John Rodrigues
RSLF - AB
DataBase: D - Guard House 04/25/19 17:26:24

C: 3
1R3 2R1

CR1

AC2

CR2

AC3 C: 1 C: 6
B

AC4

C: 2 A C: 5
AR1'

1
C: 4
1.1 1.2 2
AR2'

1R1 1R2 2R2 2R3

D101
Continuous Foundation Design
RAM Foundation v16.00.00.28
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 3
Length (m): 5.10
Width (m): 3.00
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
Uplift Safety Factor 3.2(653)
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.90 H/S 9-#20
2 1.90/ 3.20 S/S 9-#20
3 3.20/ 5.10 S/H 9-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.90 H/S 9-#20
2 1.90/ 3.20 S/S 9-#20
3 3.20/ 5.10 S/H 9-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 419.29 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 1.00 3-#20 3-#20
2 1.00/ 4.10 9-#20 9-#20
3 4.10/ 5.10 3-#20 3-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.89 Not Applic. None
2 4.21/ 5.10 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
D102
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 2/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS

Wall
s:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.10, 4.55) to (2.60, 4.55) 2.55 2499.99x200.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 17208.33 323 5.10
Provided Shear (kgf) 82805.86 5.10
Req. Max Pos. Moment (kg.m) 20013.56 323 3.80 7427.05 166 1.00
Provided Pos. Moment (kg.m) 43244.11 3.80 41256.50 1.00
Req. Max Neg. Moment (kg.m) -3751.22 181 3.80 -4496.67 171 1.00
Provided Neg. Moment (kg.m) -45959.78 3.80 -43972.18 1.00
Req. Max Punching Shear (kgf) 48588.87 180 2.55
Provided Punching Shear (kgf) 267570.07 2.55
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 4157.5 Ld Co # 663
Max Average Unfactored Soil Bearing (kg/m2) 2670.6

D103
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 3/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 6
Length (m): 4.80 (l1 = 0.70 l2 = 0.50)
Width (m): 2.10
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.80 H/S 7-#20
2 1.80/ 3.00 S/S 7-#20
3 3.00/ 4.80 S/H 7-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.80 H/S 7-#20
2 1.80/ 3.00 S/S 7-#20
3 3.00/ 4.80 S/H 7-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 419.29 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.20 1-#20 1-#20
2 0.20/ 0.80 2-#20 2-#20
3 0.80/ 4.60 11-#20 11-#20
4 4.60/ 4.80 1-#20 1-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.09 Not Applic. None
2 4.71/ 4.80 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
D104
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 4/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(2' - B) 0.70 400X400 90.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(2.60, 0.95) to (2.60, 4.55) 2.50 3599.99x200.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 6437.27 317 0.09
Provided Shear (kgf) 57964.80 0.09
Req. Max Pos. Moment (kg.m) 4690.15 317 0.50 9559.53 155 0.80
Provided Pos. Moment (kg.m) 33557.78 0.50 50427.68 0.80
Req. Max Neg. Moment (kg.m) -388.45 156 4.30 -2538.14 156 0.80
Provided Neg. Moment (kg.m) -35669.97 4.30 -53746.83 0.80
Req. Max Punching Shear (kgf) 62387.49 173 2.50
Provided Punching Shear (kgf) 323114.23 2.50
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 11452.1 Ld Co # 657
Max Average Unfactored Soil Bearing (kg/m2) 7779.0

D105
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 5/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 1
Length (m): 4.80 (l1 = 0.70 l2 = 0.50)
Width (m): 2.10
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 1.80 H/S 7-#20
2 1.80/ 3.00 S/S 7-#20
3 3.00/ 4.80 S/H 7-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.80 H/S 7-#20
2 1.80/ 3.00 S/S 7-#20
3 3.00/ 4.80 S/H 7-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 419.29 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.20 1-#20 1-#20
2 0.20/ 0.80 2-#20 2-#20
3 0.80/ 4.60 11-#20 11-#20
4 4.60/ 4.80 1-#20 1-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.09 Not Applic. None
2 4.71/ 4.80 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20
D106
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 6/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - B) 0.70 400X400 90.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.10, 0.95) to (0.10, 4.55) 2.50 3599.99x200.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 6438.94 323 0.09
Provided Shear (kgf) 57964.80 0.09
Req. Max Pos. Moment (kg.m) 4691.16 323 0.50 9560.65 198 0.80
Provided Pos. Moment (kg.m) 33557.78 0.50 50427.68 0.80
Req. Max Neg. Moment (kg.m) -388.45 162 4.30 -2538.14 150 0.80
Provided Neg. Moment (kg.m) -35669.97 4.30 -53746.83 0.80
Req. Max Punching Shear (kgf) 62389.68 179 2.50
Provided Punching Shear (kgf) 323114.23 2.50
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 11451.8 Ld Co # 663
Max Average Unfactored Soil Bearing (kg/m2) 7777.4

D107
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 7/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 4
Length (m): 1.90
Width (m): 1.70
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.95 H/S 5-#20
2 0.95/ 1.90 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 0.70 H/S 5-#20
2 0.70/ 1.20 S/S 5-#20
3 1.20/ 1.90 S/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 1.90 None 6-#20
Note: All Transverse bars are assumed hooked at ends.

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.70, 0.10) to (2.00, 0.10) 0.95 1300.00x200.00 Wall 0.00
CONCRETE CAPACITY
D108
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 8/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 0.00 -1 0.00
Provided Shear (kgf) 0.00 0.00
Req. Max Pos. Moment (kg.m) 305.27 1 1.60 2263.05 1 0.00
Provided Pos. Moment (kg.m) 24034.16 1.60 27454.08 0.00
Req. Max Neg. Moment (kg.m) -0.00 2 0.00 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25542.86 0.00 -0.00 0.00
Req. Max Punching Shear (kgf) 9132.61 1 0.95
Provided Punching Shear (kgf) 212450.42 0.95
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 3112.2 Ld Co # 368
Max Average Unfactored Soil Bearing (kg/m2) 3109.5

D109
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 9/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 5
Length (m): 1.84 (l1 = 0.30 l2 = 0.50)
Width (m): 1.50
Thickness (m): 0.50
Footing Orientation (deg): 54.78º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.90 H/S 5-#20
2 0.90/ 1.84 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.84 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 1.25 None 4-#20
2 1.25/ 1.84 None 2-#20
Note: All Transverse bars are assumed hooked at ends.

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(2' - B) 1.34 400X400 54.78 N/A 0

Walls:
Loc. Along Size
D110
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 10/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(2.00, 0.10) to (2.60, 0.95) 0.82 1040.43x200.00 Wall -0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 0.00 -1 0.00
Provided Shear (kgf) 0.00 0.00
Req. Max Pos. Moment (kg.m) 776.82 1 1.54 1588.40 1 0.00
Provided Pos. Moment (kg.m) 24033.97 1.54 18297.30 0.00
Req. Max Neg. Moment (kg.m) -0.00 1 1.84 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25542.68 1.84 -0.00 0.00
Req. Max Punching Shear (kgf) 9888.75 1 1.34
Provided Punching Shear (kgf) 173228.78 1.34
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 7710.5 Ld Co # 368
Max Average Unfactored Soil Bearing (kg/m2) 5580.5

D111
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 11/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 2
Length (m): 1.84 (l1 = 0.50 l2 = 0.30)
Width (m): 1.50
Thickness (m): 0.50
Footing Orientation (deg): 305.22º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 0.90 H/S 5-#20
2 0.90/ 1.84 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 1.84 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.60 None 2-#20
2 0.60/ 1.84 None 4-#20
Note: All Transverse bars are assumed hooked at ends.

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - B) 0.50 400X400 305.22 N/A 0

Walls:
Loc. Along Size
D112
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 12/12
John Rodrigues
RSLF - AB
DataBase: D - Guard House Date: 05/01/19 12:22:24
Building Code: IBC Design Code: ACI318-14
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.10, 0.95) to (0.70, 0.10) 1.02 1040.43x200.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 0.00 -1 0.00
Provided Shear (kgf) 0.00 0.00
Req. Max Pos. Moment (kg.m) 767.00 1 0.30 1495.17 1 0.60
Provided Pos. Moment (kg.m) 24033.97 0.30 18293.90 0.60
Req. Max Neg. Moment (kg.m) -0.00 1 0.00 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25542.68 0.00 -0.00 0.00
Req. Max Punching Shear (kgf) 9868.37 1 0.50
Provided Punching Shear (kgf) 173228.78 0.50
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 7698.4 Ld Co # 368
Max Average Unfactored Soil Bearing (kg/m2) 5569.5

D113
D114
One-Way Slab Design

Job = RSLF - ARTILLERY BRIGADE 127-269162-19001 Designer JSR Date 5/7/2019


Building = Guard House GH Checker Date

Notes = ROOF SLAB IS SUPPORTED BY 200mm THICK CONCRETE WALLS

STAAD | Nodes & Plates

X = 2500 mm (8.2 ft)


Cl of Beam to Cl of Beam

Exterior Beam B1: W = 200mm (0.656ft )


Exterior Beam B3: W = 200mm (0.656ft )

Exterior Beam B4: W = 200mm (0.656ft )

Z_cs = 4250 mm Say --> 14 ft


Cl of Beam to Cl of Beam

Clear Span
Z = 4450 mm (14.6 ft)

Clear Span
Clear Span
B4

Z B5

Exterior Beam B2: W = 200mm (0.656ft )

X_cs = 2300 mm Say --> 8 ft


Clear Span

Cl to Cl Span
X= 2500 mm 8.20 ft
Z= 4450 mm 14.60 ft

Beam Width Cl to Interior Face


Beam Location W (mm) W (ft) (mm) (ft)
B1 Exterior 200 0.66 100 0.33
B2 Exterior 200 0.66 100 0.33
B3 Exterior 200 0.66 100 0.33
B4 Exterior 200 0.66 100 0.33

Clear Span
X_cs = 2300 mm 7.50 ft SAY --> X_cs = 8.00 ft
Z_cs = 4250 mm 13.90 ft Z_cs = 14.00 ft

Overhang (x direction has the largest overhang)


X_oh = 1647 mm 5.40 ft SAY --> X_oh = 6.00 ft

D115 PAGE 1 OF 2
Number of Nodes = 315
Number of Plates = 280

LOADS (Facilities with the maximum loads were used)


Dead Loads
Surface Loads
HVAC (Minor) = 10.00 psf 0.01 ksf
Collateral Dead Load = 10.00 psf 0.01 ksf
Roof Topping = 65.00 psf 0.07 ksf

Total Dead Load = 85.00 psf 0.09 ksf

Parapet Load
Concrete Weight = 150.00 pcf
Parapet Height = 1500 mm 4.92 ft

Parapet Dead Load = 738.00 psf 0.74 ksf

Live Loads
Roof Live Load = 20.00 psf 0.02 ksf

D116 PAGE 2 OF 2
Job No Sheet No Rev
127-269162-19001 1
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Job Information
Engineer Checked Approved

Name: JSR
Date: 07-May-19

Structure Type SPACE FRAME

Number of Nodes 315 Highest Node 315


Number of Plates 280 Highest Plate 3083

Number of Basic Load Cases 2


Number of Combination Load Cases 5

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DL
Primary 2 RLL
Combination 3 GENERATED ACI TABLE1 1
Combination 4 GENERATED ACI TABLE1 2
Combination 5 GENERATED ACI TABLE1 3
Combination 6 GENERATED ACI TABLE1 4
Combination 7 GENERATED ACI TABLE1 5

Materials
Mat Name E ν Density α
(kip/in2) (kip/in3) (/°F)
1 STEEL 29E+3 0.300 0.000 6E -6
2 STAINLESSSTEEL 28E+3 0.300 0.000 10E -6
3 ALUMINUM 10E+3 0.330 0.000 13E -6
4 CONCRETE 3.15E+3 0.170 0.000 5E -6

Plate Thickness
Prop Node A Node B Node C Node D Material
(in) (in) (in) (in)
1 7.874 7.874 7.874 7.874 CONCRETE

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 9

D117
Job No Sheet No Rev
127-269162-19001 2
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates
Plate Node A Node B Node C Node D Property

1000 92 107 106 91 1


1001 93 108 107 92 1
1002 94 109 108 93 1
1003 95 110 109 94 1
1004 96 111 110 95 1
1005 97 112 111 96 1
1006 98 113 112 97 1
1007 99 114 113 98 1
1008 100 115 114 99 1
1009 101 116 115 100 1
1010 102 117 116 101 1
1011 103 118 117 102 1
1012 104 119 118 103 1
1013 105 120 119 104 1
1014 107 122 121 106 1
1015 108 123 122 107 1
1016 109 124 123 108 1
1017 110 125 124 109 1
1018 111 126 125 110 1
1019 112 127 126 111 1
1020 113 128 127 112 1
1021 114 129 128 113 1
1022 115 130 129 114 1
1023 116 131 130 115 1
1024 117 132 131 116 1
1025 118 133 132 117 1
1026 119 134 133 118 1
1027 120 135 134 119 1
1028 122 137 136 121 1
1029 123 138 137 122 1
1030 124 139 138 123 1
1031 125 140 139 124 1
1032 126 141 140 125 1
1033 127 142 141 126 1
1034 128 143 142 127 1
1035 129 144 143 128 1
1036 130 145 144 129 1
1037 131 146 145 130 1
1038 132 147 146 131 1
1039 133 148 147 132 1
1040 134 149 148 133 1
1041 135 150 149 134 1
1042 137 152 151 136 1
1043 138 153 152 137 1
1044 139 154 153 138 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 9

D118
Job No Sheet No Rev
127-269162-19001 3
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

1045 140 155 154 139 1


1046 141 156 155 140 1
1047 142 157 156 141 1
1048 143 158 157 142 1
1049 144 159 158 143 1
1050 145 160 159 144 1
1051 146 161 160 145 1
1052 147 162 161 146 1
1053 148 163 162 147 1
1054 149 164 163 148 1
1055 150 165 164 149 1
1056 152 167 166 151 1
1057 153 168 167 152 1
1058 154 169 168 153 1
1059 155 170 169 154 1
1060 156 171 170 155 1
1061 157 172 171 156 1
1062 158 173 172 157 1
1063 159 174 173 158 1
1064 160 175 174 159 1
1065 161 176 175 160 1
1066 162 177 176 161 1
1067 163 178 177 162 1
1068 164 179 178 163 1
1069 165 180 179 164 1
1070 167 182 181 166 1
1071 168 183 182 167 1
1072 169 184 183 168 1
1073 170 185 184 169 1
1074 171 186 185 170 1
1075 172 187 186 171 1
1076 173 188 187 172 1
1077 174 189 188 173 1
1078 175 190 189 174 1
1079 176 191 190 175 1
1080 177 192 191 176 1
1081 178 193 192 177 1
1082 179 194 193 178 1
1083 180 195 194 179 1
1084 182 197 196 181 1
1085 183 198 197 182 1
1086 184 199 198 183 1
1087 185 200 199 184 1
1088 186 201 200 185 1
1089 187 202 201 186 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 9

D119
Job No Sheet No Rev
127-269162-19001 4
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

1090 188 203 202 187 1


1091 189 204 203 188 1
1092 190 205 204 189 1
1093 191 206 205 190 1
1094 192 207 206 191 1
1095 193 208 207 192 1
1096 194 209 208 193 1
1097 195 210 209 194 1
1098 197 212 211 196 1
1099 198 213 212 197 1
1100 199 214 213 198 1
1101 200 215 214 199 1
1102 201 216 215 200 1
1103 202 217 216 201 1
1104 203 218 217 202 1
1105 204 219 218 203 1
1106 205 220 219 204 1
1107 206 221 220 205 1
1108 207 222 221 206 1
1109 208 223 222 207 1
1110 209 224 223 208 1
1111 210 225 224 209 1
2000 2 17 16 1 1
2001 3 18 17 2 1
2002 4 19 18 3 1
2003 5 20 19 4 1
2004 6 21 20 5 1
2005 7 22 21 6 1
2006 8 23 22 7 1
2007 9 24 23 8 1
2008 10 25 24 9 1
2009 11 26 25 10 1
2010 12 27 26 11 1
2011 13 28 27 12 1
2012 14 29 28 13 1
2013 15 30 29 14 1
2014 17 32 31 16 1
2015 18 33 32 17 1
2016 19 34 33 18 1
2017 20 35 34 19 1
2018 21 36 35 20 1
2019 22 37 36 21 1
2020 23 38 37 22 1
2021 24 39 38 23 1
2022 25 40 39 24 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 9

D120
Job No Sheet No Rev
127-269162-19001 5
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

2023 26 41 40 25 1
2024 27 42 41 26 1
2025 28 43 42 27 1
2026 29 44 43 28 1
2027 30 45 44 29 1
2028 32 47 46 31 1
2029 33 48 47 32 1
2030 34 49 48 33 1
2031 35 50 49 34 1
2032 36 51 50 35 1
2033 37 52 51 36 1
2034 38 53 52 37 1
2035 39 54 53 38 1
2036 40 55 54 39 1
2037 41 56 55 40 1
2038 42 57 56 41 1
2039 43 58 57 42 1
2040 44 59 58 43 1
2041 45 60 59 44 1
2042 47 62 61 46 1
2043 48 63 62 47 1
2044 49 64 63 48 1
2045 50 65 64 49 1
2046 51 66 65 50 1
2047 52 67 66 51 1
2048 53 68 67 52 1
2049 54 69 68 53 1
2050 55 70 69 54 1
2051 56 71 70 55 1
2052 57 72 71 56 1
2053 58 73 72 57 1
2054 59 74 73 58 1
2055 60 75 74 59 1
2056 62 77 76 61 1
2057 63 78 77 62 1
2058 64 79 78 63 1
2059 65 80 79 64 1
2060 66 81 80 65 1
2061 67 82 81 66 1
2062 68 83 82 67 1
2063 69 84 83 68 1
2064 70 85 84 69 1
2065 71 86 85 70 1
2066 72 87 86 71 1
2067 73 88 87 72 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 9

D121
Job No Sheet No Rev
127-269162-19001 6
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

2068 74 89 88 73 1
2069 75 90 89 74 1
2070 77 92 91 76 1
2071 78 93 92 77 1
2072 79 94 93 78 1
2073 80 95 94 79 1
2074 81 96 95 80 1
2075 82 97 96 81 1
2076 83 98 97 82 1
2077 84 99 98 83 1
2078 85 100 99 84 1
2079 86 101 100 85 1
2080 87 102 101 86 1
2081 88 103 102 87 1
2082 89 104 103 88 1
2083 90 105 104 89 1
3000 212 227 226 211 1
3001 213 228 227 212 1
3002 214 229 228 213 1
3003 215 230 229 214 1
3004 216 231 230 215 1
3005 217 232 231 216 1
3006 218 233 232 217 1
3007 219 234 233 218 1
3008 220 235 234 219 1
3009 221 236 235 220 1
3010 222 237 236 221 1
3011 223 238 237 222 1
3012 224 239 238 223 1
3013 225 240 239 224 1
3014 227 242 241 226 1
3015 228 243 242 227 1
3016 229 244 243 228 1
3017 230 245 244 229 1
3018 231 246 245 230 1
3019 232 247 246 231 1
3020 233 248 247 232 1
3021 234 249 248 233 1
3022 235 250 249 234 1
3023 236 251 250 235 1
3024 237 252 251 236 1
3025 238 253 252 237 1
3026 239 254 253 238 1
3027 240 255 254 239 1
3028 242 257 256 241 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 6 of 9

D122
Job No Sheet No Rev
127-269162-19001 7
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

3029 243 258 257 242 1


3030 244 259 258 243 1
3031 245 260 259 244 1
3032 246 261 260 245 1
3033 247 262 261 246 1
3034 248 263 262 247 1
3035 249 264 263 248 1
3036 250 265 264 249 1
3037 251 266 265 250 1
3038 252 267 266 251 1
3039 253 268 267 252 1
3040 254 269 268 253 1
3041 255 270 269 254 1
3042 257 272 271 256 1
3043 258 273 272 257 1
3044 259 274 273 258 1
3045 260 275 274 259 1
3046 261 276 275 260 1
3047 262 277 276 261 1
3048 263 278 277 262 1
3049 264 279 278 263 1
3050 265 280 279 264 1
3051 266 281 280 265 1
3052 267 282 281 266 1
3053 268 283 282 267 1
3054 269 284 283 268 1
3055 270 285 284 269 1
3056 272 287 286 271 1
3057 273 288 287 272 1
3058 274 289 288 273 1
3059 275 290 289 274 1
3060 276 291 290 275 1
3061 277 292 291 276 1
3062 278 293 292 277 1
3063 279 294 293 278 1
3064 280 295 294 279 1
3065 281 296 295 280 1
3066 282 297 296 281 1
3067 283 298 297 282 1
3068 284 299 298 283 1
3069 285 300 299 284 1
3070 287 302 301 286 1
3071 288 303 302 287 1
3072 289 304 303 288 1
3073 290 305 304 289 1

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 7 of 9

D123
Job No Sheet No Rev
127-269162-19001 8
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Plates Cont...
Plate Node A Node B Node C Node D Property

3074 291 306 305 290 1


3075 292 307 306 291 1
3076 293 308 307 292 1
3077 294 309 308 293 1
3078 295 310 309 294 1
3079 296 311 310 295 1
3080 297 312 311 296 1
3081 298 313 312 297 1
3082 299 314 313 298 1
3083 300 315 314 299 1

Supports
Node X Y Z rX rY rZ
(kip/in) (kip/in) (kip/in) (kip-ft/deg) (kip-ft/deg) (kip-ft/deg)
91 Fixed Fixed Fixed - Fixed -
92 - Fixed - - - -
93 - Fixed - - - -
94 - Fixed - - - -
95 - Fixed - - - -
96 - Fixed - - - -
97 - Fixed - - - -
98 - Fixed - - - -
99 - Fixed - - - -
100 - Fixed - - - -
101 - Fixed - - - -
102 - Fixed - - - -
103 - Fixed - - - -
104 - Fixed - - - -
105 Fixed Fixed Fixed - Fixed -
211 Fixed Fixed Fixed - Fixed -
212 - Fixed - - - -
213 - Fixed - - - -
214 - Fixed - - - -
215 - Fixed - - - -
216 - Fixed - - - -
217 - Fixed - - - -
218 - Fixed - - - -
219 - Fixed - - - -
220 - Fixed - - - -
221 - Fixed - - - -
222 - Fixed - - - -
223 - Fixed - - - -
224 - Fixed - - - -

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 8 of 9

D124
Job No Sheet No Rev
127-269162-19001 9
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

Supports Cont...
Node X Y Z rX rY rZ
(kip/in) (kip/in) (kip/in) (kip-ft/deg) (kip-ft/deg) (kip-ft/deg)
225 Fixed Fixed Fixed - Fixed -

Primary Load Cases


Number Name Type

1 DL Dead
2 RLL Roof Live

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

3 GENERATED ACI TABLE1 1 1 DL 1.40


4 GENERATED ACI TABLE1 2 1 DL 1.20
2 RLL 0.50
5 GENERATED ACI TABLE1 3 1 DL 1.20
6 GENERATED ACI TABLE1 4 1 DL 1.20
2 RLL 1.60
7 GENERATED ACI TABLE1 5 1 DL 0.90

3070
3056
3042 3071
3028 3057
3043 3072
3014
3029 3058
3000 3073
3015 3044
1098 3059
3001 3030
1084 3045 3074
1099 3016
1070 3031 3060
1085 3002 3075
1056 3017 3046
1071 1100 3061
1042 3003 3032
1057 1086 3047 3076
1028 1101 3018
1043 1072 3033 3062
1014 1087 3004 3077
1029 1058 3019 3048
1000 1073 1102 3063
1015 1044 3005 3034
2070 1059 1088 3049 3078
1001 1030 1103 3020
2056 1045 1074 3035 3064
2071 1016 1089 3006 3079
2042 1031 1060 3021 3050
2057 1002 1075 1104 3065
2028 1017 1046 3007 3036
2043 2072 1061 1090 3051 3080
2014 1003 1032 1105 3022
2029 2058 1047 1076 3037 3066
2000 2073 1018 1091 3008 3081
2015 2044 1033 1062 3023 3052
2059 1004 1077 1106 3067
2001 2030 1019 1048 3009 3038
2045 2074 1063 1092 3053 3082
2016 1005 1034 1107 3024
2031 2060 1049 1078 3039 3068
2002 2075 1020 1093 3010 3083
2017 2046 1035 1064 3025 3054
2061 1006 1079 1108 3069
2003 2032 1021 1050 3011 3040
2047 2076 1065 1094 3055
2018 1007 1036 1109 3026
2033 2062 1051 1080 3041
2004 2077 1022 1095 3012
2019 2048 1037 1066 3027
2063 1008 1081 1110
2005 2034 1023 1052 3013
2049 2078 1067 1096
2020 1009 1038 1111
2035 2064 1053 1082
2006 2079 1024 1097
2021 2050 1039 1068
2065 1010 1083
2007 2036 1025 1054
2051 2080 1069
2022 1011 1040
2037 2066 1055
2008 2081 1026
2023 2052 1041
2067 1012
2009 2038 1027
2053 2082
2024 1013
2039 2068
2010 2083
2025 2054
2040 2069
2011
2026 2055
2012 2041
2027
2013

Y
X
Whole Structure - Supports & Plate #s

Print Time/Date: 07/05/2019 14:47 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 9 of 9

D125
Job No Sheet No Rev
127-269162-19001 1
Part
Software licensed to Tetra Tech Inc
Job Title GH 1-way slab design Ref

By JSR Date07-May-19 Chd

Client RSLF - Artillery Brigade File 1 way roof slab.std Date/Time 07-May-2019 14:46

2000 2014 2028 2042 2056 2070 1000 1014 1028 1042 1056 1070 1084 1098 3000 3014 3028 3042 3056 3070

2001 2015 2029 2043 2057 2071 1001 1015 1029 1043 1057 1071 1085 1099 3001 3015 3029 3043 3057 3071

2002 2016 2030 2044 2058 2072 1002 1016 1030 1044 1058 1072 1086 1100 3002 3016 3030 3044 3058 3072

2003 2017 2031 2045 2059 2073 1003 1017 1031 1045 1059 1073 1087 1101 3003 3017 3031 3045 3059 3073

2004 2018 2032 2046 2060 2074 1004 1018 1032 1046 1060 1074 1088 1102 3004 3018 3032 3046 3060 3074

2005 2019 2033 2047 2061 2075 1005 1019 1033 1047 1061 1075 1089 1103 3005 3019 3033 3047 3061 3075

2006 2020 2034 2048 2062 2076 1006 1020 1034 1048 1062 1076 1090 1104 3006 3020 3034 3048 3062 3076

2007 2021 2035 2049 2063 2077 1007 1021 1035 1049 1063 1077 1091 1105 3007 3021 3035 3049 3063 3077

2008 2022 2036 2050 2064 2078 1008 1022 1036 1050 1064 1078 1092 1106 3008 3022 3036 3050 3064 3078

2009 2023 2037 2051 2065 2079 1009 1023 1037 1051 1065 1079 1093 1107 3009 3023 3037 3051 3065 3079

2010 2024 2038 2052 2066 2080 1010 1024 1038 1052 1066 1080 1094 1108 3010 3024 3038 3052 3066 3080

2011 2025 2039 2053 2067 2081 1011 1025 1039 1053 1067 1081 1095 1109 3011 3025 3039 3053 3067 3081

2012 2026 2040 2054 2068 2082 1012 1026 1040 1054 1068 1082 1096 1110 3012 3026 3040 3054 3068 3082

Y X 2013 2027 2041 2055 2069 2083 1013 1027 1041 1055 1069 1083 1097 1111 3013 3027 3041 3055 3069 3083 Load 1
Z

Whole Structure - Plate #s


MAX MOMENT = 8.285 k-in/in
= 8.285 k-in/in X 12 in/ft = 99.420 k-in/ft
Plate Center Stress Summary
Shear Membrane Bending
Plate L/C Qx Qy Sx Sy Sxy Mx My Mxy
(psi) (psi) (psi) (psi) (psi) (kip-in/in) (kip-in/in) (kip-in/in)
Max Qx 2082 3:GENERATED ACI 27.281
TABLE1 1 6.755 0.000 0.000 0.000 7.415 1.096 -0.021
Min Qx 3001 3:GENERATED ACI-27.281
TABLE1 1 -6.755 0.000 0.000 0.000 7.415 1.096 -0.021
Max Qy 1013 3:GENERATED ACI TABLE1
5.363 1 16.176 0.000 0.000 0.000 7.652 0.540 0.370
Min Qy 1000 3:GENERATED ACI TABLE1
5.363 1 -16.176 0.000 0.000 0.000 7.652 0.540 -0.370
Max Sx 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Min Sx 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Max Sy 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Min Sy 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Max Sxy 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Min Sxy 1000 1:DL 3.831 -11.554 0.000 0.000 0.000 5.466 0.386 -0.264
Max Mx 1003 3:GENERATED ACI-11.872
TABLE1 1 -0.043 0.000 0.000 0.000 8.285 1.391 -0.023
Min Mx 2013 2:RLL 0.116 -0.019 0.000 0.000 0.000 0.005 0.001 0.001
Max My 1006 3:GENERATED ACI-10.386
TABLE1 1 0.050 0.000 0.000 0.000 8.258 1.408 0.002
Min My 2012 3:GENERATED ACI TABLE1
5.856 1 -0.274 0.000 0.000 0.000 0.303 -0.068 0.006
Max Mxy 1013 3:GENERATED ACI TABLE1
5.363 1 16.176 0.000 0.000 0.000 7.652 0.540 0.370
Min Mxy 1111 3:GENERATED ACI TABLE1
-5.363 1 16.176 0.000 0.000 0.000 7.652 0.540 -0.370

Print Time/Date: 07/05/2019 14:48 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1

D126
D127
D128
SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
E. Fire Pump House

Building Design Page No.

RAM Calculation Check…………………………………...…...……………………………………………… E 1 - E2

RAM Back-Up Calculations……………………………………………………………...…………………… E3 - E7

RAM Model…………………………………………………..…………………………………………………… E 8 - E 29

RAM Frame Analysis…………………………………………………………………………………………… E 30 - E 61

RAM Concrete Design…………………………………………………...…………………………………… E 62 - E 106

RAM Foundation Design………………………………………………….…………………………………… E 107 - E 140

Slab on Grade Design……………………………...………………………...………………………………… E 141 - E 141

Roof Slab Design…………………………………..…………………………...……………………………… E 142 - E 153

Parapet Design………………………………………………..…………………...…………………………… E 154 - E 154

CMU Wall Design……………………………………………………….…………...………………………… E 155 - E 164


E1
E2
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\E - Fire Pump House\RAM\
FPH backup
Geometry

FIRE PUMP HOUSE


BUILDING GEOMETRY
Building Lengths
Ext Face of Wall to Ext Face of Wall
Overall (Out to Out) 8700 mm 8.70 m 28.54 ft <-- Ext Face of Columns Along Grids 1 to 3

CL to CL of Exterior Columns/Walls
Overall (CL to CL) 8300 mm 8.30 m 27.22 ft <-- CL to CL of Exterior Columns Along Grids 1' to 3'

Building Widths
Ext Face of Wall to Ext Face of Wall
Overall (Out to Out) 11200 mm 11.20 m 36.74 ft <-- Ext Face of Columns Along Grids A to C

CL to CL of Exterior Columns/Walls
Overall (CL to CL) 10800 mm 10.80 m 35.42 ft <-- CL to CL of Exterior Columns Along Grids A' to C'

Column Size Beam Size


Length 400 mm 0.40 m 1.31 ft Width 500 mm 0.50 m 1.64 ft
B1
Width 400 mm 0.40 m 1.31 ft Depth 550 mm 0.55 m 1.80 ft

Width 600 mm 0.60 m 1.97 ft


B2
Depth 550 mm 0.55 m 1.80 ft

GRID GEOMETRY FIRE PUMP HOUSE


MAIN GRIDLINE LOCATIONS FOR RAM INPUT (SEE CALCULATION BELOW)

X-GRID ALONG X Y-GRID ALONG Y


X m Y m
1 0.0000 A 0.0000 1 Xi
1' 0.2000 A' 0.2000
2 4.3500 B 5.6000
3' 8.5000 C' 11.0000 Yi
3 8.7000 C 11.2000
y
X
A 0,

CALCULATE GRIDLINE LOCATIONS

X-GRID to GRID CL TO CL X-GRID ALONG X ALONG X Y-GRID to GRID CL TO CL Y-GRID ALONG Y ALONG Y A-B 5600 1-2 4350
0 0 mm m 0 0 mm m B-C 5600 2-3 4350
1 1' 200 1 0 0.000 A A' 200 A 0 0.000
1' 2 4150 1' 200 0.200 A' B 5400 A' 200 0.200
2 3' 4150 2 4350 4.350 B C' 5400 B 5600 5.600
3' 3 200 3' 8500 8.500 C' C 200 C' 11000 11.000
3 3 8700 8.700 C C 11200 11.200

Length 8700 8.70 28.54 ft Width 11200 11.20 36.74 ft A-C 11200 1-3 8700
Max Span 4150 4.15 13.61 ft Max Span 5400 5.40 17.71 ft
Min Span 200 0.20 0.66 ft Min Span 200 0.20 0.66 ft

FLOOR TYPE & STORY LABELS FIRE PUMP HOUSE


Building Elevations

Top of Footing -1000 mm -1.00 m -3.28 ft Story Elevation/Story Height


Bottom of Column/Wall 0 mm 0.00 m 0.00 ft 1 4000
Top of Ground Slab 0 mm 0.00 m 0.00 ft
Bottom of Roof 3800 mm 3.80 m 12.46 ft
Top of Roof 4000 mm 4.00 m 13.12 ft

Top of Parapet 5600 mm 5.60 m 18.37 ft


Bottom of Parapet 4000 mm 4.00 m 13.12 ft

Parapet Height 1600 mm 1.60 m 5.25 ft

Ground Floor Slab Thickness 150 mm 0.15 m 0.49 ft


Roof Slab Thickness 200 mm 0.20 m 0.66 ft

EL of Floor Type (Layout) Story


Level Story Label Level Description Height
Floor Type ID
(mm) (m)
1 T.O. Roof 4000 Top of Roof Slab Ground Floor 4.00

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
E3 Page 1 of 1
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\E - Fire Pump House\RAM\
FPH backup
LOADS

GENERAL INFORMATION FIRE PUMP HOUSE

Job = Royal Saudi Land Force (RSLF), Artillery Brigade


Building = Fire Pump House

Codes : ACI 318-14


IBC 2015
ASCE 7-10
UFC 3-301-01, Sept. 2016

Country : KSA
Base / City : Eastern Province

Risk Category : IV UFC 3-301-01 Table 2-2


IV

Importance Factors
Iw = 1.00 UFC 3-301-01 Table 2-2
Is = 1.20 UFC 3-301-01 Table 2-2
Ie = 1.50 UFC 3-301-01 Table 2-2

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
E4 Page 1 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\E - Fire Pump House\RAM\
FPH backup
LOADS

LOADS FIRE PUMP HOUSE

DEAD LOADS

Roofing Dead Load

Building Width = 11200 mm


Cricket Width = 3000 mm

Roof is double pitched


unique roof areas = 4
area width = 1400.00 mm

rise run
roof slope = 42 1000

ROOFING MATERIAL
Cellular Concrete Unit Weight = 50 pcf 800.92 kg/cu_m
Insulation & Concrete Pavers = 20 psf 97.65 kg/sq_m

AREA
1 2 3 4
distance from center of area to edge of roof (mm) = 700 2100 3500 4900
avg. roof thickness in area (mm) = 126.00 126.00 147.60 205.80
Cellular Concrete Load (kg/sq_m) = 100.92 100.92 118.22 164.83
Insulation & Paver Load (kg/sq_m) = 97.65 97.65 97.65 97.65
Total (kg/sq_m) = 198.56 198.56 215.86 262.48
Say --> 200 200 220 265

Dead Load due to Exterior Walls

Wall Type : Concrete

Concrete Weight = 150 pcf 2403 kg/cu_m


Wall Thickness = 8 in 200 mm
Ground Floor Wall Height = 13.12 ft 4000 mm
Parapet Height = 5.25 ft 1600 mm

Line Load Type Height Load Height Load Say Mass Dead Load
h (m) ft plf m kg/m kg/m Location % kg/m
Concrete (Roof) h =4 13.12 1312 4.00 1922 1930 Roof 50% 965
Concrete (Stem Wall) h =4 13.12 1312 4.00 1922 1930 Stem Wall 50% 965
Concrete (Parapet) h =1.6 5.25 525 1.60 769 770 Parapet 100% 770

Wall Type : CMU Veneer

CMU Veneer Weight = 45 psf 220 kg/sq_m


Veneer Thickness = 4 in 100 mm
Ground Floor Wall Height = 13.12 ft 4000 mm
Parapet Height = 5.25 ft 1600 mm

Line Load Type Height Load Height Load Say Mass Dead Load
h (m) ft plf m kg/m kg/m Location % kg/m
CMU Veneer (Roof) h =4 13.12 591 4.00 879 880 Roof 50% 440
CMU Veneer (Stem Wall) h =4 13.12 591 4.00 879 880 Stem Wall 50% 440
CMU Veneer (Parapet) h =1.6 5.25 236 1.60 352 360 Parapet 100% 360

Dead Load due to Partition Wall

Wall Type : CMU

CMU Weight = 90 psf 439 kg/sq_m


Wall Thickness = 8 in 200 mm
Wall Height = 13.12 ft 4000 mm

Surface Load Type Height Length Load Say Mass Dead Load
h (m) m m kg/m kg/m Location % kg/m
200 CMU Partition (Roof) h =4 4 varies 1758 1760 Roof 50% 880

Collateral Dead Load

DLCL = 10 psf 50 kg/sq_m

HVAC (Minor)

DLHVAC = 10 psf 50 kg/sq_m

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
E5 Page 2 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\E - Fire Pump House\RAM\
FPH backup
LOADS

LIVE LOADS

Roof Live Load

Min. Roof LL = 20 psf 97.65 kg/sq_m 957.6 Pa UFC 3-301-01 Table D-1
Given Roof Live Load = 20.89 psf 101.97 kg/sq_m 1000 Pa

Governing Roof LL = 101.97 kg/sq_m Say --> 102 kg/sq_m

SURFACE LOAD SUMMARY

TOTAL
DLCL DLHVAC DLRoofing LLRoof
LOAD DL LL MDL
kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m kg/sq_m
Roof -Area 1 50 50 200 102 300 102 300
Roof -Area 2 50 50 200 102 300 102 300
Roof -Area 3 50 50 220 102 320 102 320
Roof -Area 4 50 50 265 102 365 102 365

LINE LOAD SUMMARY

DLVeneer DLVeneer TOTAL


DLParapet DLWall
LOAD (Parapet) (Wall) DL MDL
kg/m kg/m kg/m kg/m kg/m kg/m
DL: P + V 770 360 0 440 1130 1570
DL: P + W + V 770 360 965 440 1130 2535
DL: W @ STEM WALL 0 0 1930 880 2810 1405
DL: V @ STEM WALL 0 0 0 880 880 440
DL: 200 Partition @ Roof 0 0 880 0 0 880

SNOW LOAD

Importance Factor, Is = 1.20


Ground Snow = 0 psf 0 kPa UFC 3-301-01 Table F-1
Frost Pentration = 0 in 0 mm

WIND LOADS

Importance Factor, Iw = 1.00 Wind Speed, V = 115 mph 185 km/hr UFC 3-301-01 Table F-1
Exposure : C Directionality Factor, Kd = 0.85 ASCE 7-10 Table 26.6-1
Risk Category : IV Topographic Factor, Kzt = 1 ASCE 7-10 26.8.2
Velocity Pressure Exposure Coefficient Kh = 0.886 ASCE 7-10 Table 27.3-1
2
qz = 0.00256KzKztKdV = 25.47 psf 124.37 kg/sq_m ASCE 7-10 27.3.2

Parapet Height = 1.600 m <-- Added to Exposure in RAM

SEISMIC LOADS

Importance Factor, Ie = 1.50


Risk Category : IV
Site Class : D IBC 2012 1613.3.2
Peak Ground Acceleration, PGA = 14% g UFC 3-301-01 Table F-3
Ss = 37% g
S1 = 17% g

Seismic Design Category, SDC : D ASCE 7-10


Seismic Force Resisting System : SPECIAL REINFORCED CONCRETE SHEAR WALLS ASCE 7-10 Table 12.2-1
g
Height Limit : NO LIMIT Overstrength Factor, Ω0 = 2.5
Response Modification Coeff., Ra = 5 Deflection Amplification Factor, Cdb = 5

T0 = 0.2SD1/SDS = 0.130 SDS = 0.371 g Ct = 0.0488 ASCE 7-10 Table 12.8-2


TS = SD1/SDS = 0.648 SD1 = 0.240 g x= 0.75
hn = 4.00 m
x
Approx. Fundamental Period, Ta = Cthn
Ta = 0.138 sec Total Building Weight, W = 216,613 kg <-- VALUE TAKEN FROM RAM
Fundamental Period, T = Ta Seismic Response Coefficient, Cs = 0.111 =SDS/(R/Ie)
Seismic Base Shear, V = CsW = 24,108 kg ASCE 7-10 Equation 12.8-1

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
E6 Page 3 of 3
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\E - Fire Pump House\RAM\
FPH backup
Seismic Calcs

SEISMIC DESIGN PARAMETERS FIRE PUMP HOUSE

PGA = 0.14 g
(0.2s) Ss = 0.37 g
(0.1s) S1 = 0.17 g
Site Class : D

ASCE 7-10 TABLE 11.8-1


SITE COEFFICIENT, FPGA
SITE PEAK GROUND ACCELERATION COEFFICIENT
CLASS PGA ≤ 0.1 PGA = 0.2 PGA = 0.3 PGA = 0.4 PGA ≥ 0.5
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7

FPGA = 1.52
PGAM = FPGAPGA = 0.2128

ASCE 7-10 TABLE 11.4-1


SITE COEFFICIENT, FA
SITE MCER AT SHORT PERIOD
CLASS SS ≤ 0.25 SS = 0.5 SS = 0.75 SS = 1.0 SS ≥ 1.25
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.2 1.2 1.1 1.0 1.0
D 1.6 1.4 1.2 1.1 1.0
E 2.5 1.7 1.2 0.9 0.9
F See Section 11.4.7

FA = 1.504 Seismic Design Category : D


SMS = FASS = 0.55648 SDS = (2/3)SMS = 0.371

ASCE 7-10 TABLE 11.4-2


SITE COEFFICIENT, FV
SITE MCER AT 1-s PERIOD
CLASS S1 ≤ 0.1 S1 = 0.2 S1 = 0.3 S1 = 0.4 S1 ≥ 0.5
A 0.8 0.8 0.8 0.8 0.8
B 1.0 1.0 1.0 1.0 1.0
C 1.7 1.6 1.5 1.4 1.3
D 2.4 2.0 1.8 1.6 1.5
E 3.5 3.2 2.8 2.4 2.4
F See Section 11.4.7

FV = 2.12 Seismic Design Category : D


SM1 = FVS1 = 0.3604 SD1 = (2/3)SM1 = 0.240

SUMMARY
PGAM = 0.2128
SDS = 0.3710 SDC : D
SD1 = 0.2403 SDC : D

Governing SDC : D

Designed by: __JSR__ Date: ____4/25/2019____


Checked by: _______ Date: _______________
E7 Page 1 of 1
General Criteria
RAM Structural System 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC

BUILDING CODE FOR LIVE LOAD REDUCTION: IBC


Live Load Reduction Method: General

ROOF LOADS:
Consider Roof Live Loads, Ignore Snow Loads
Roof Live Loads are Unreducible

DETERMINING NUMBER OF STORIES FOR LIVE LOAD REDUCTION:


Include Roof Levels: No
Include Unreducible Levels: Yes
Include Storage Levels: Yes

SELF-WEIGHT:
Automatically calculate and include Self-Weight for Member Dead Loads:
Beams: Yes
Columns: Yes
Walls: Yes
Slabs / Decks: Yes

Automatically calculate and include Self-Weight for Story Masses:


Beams: Yes
Columns: Yes
Include half mass of columns above and below
Walls: Yes
Include half mass of walls above and below
Slabs / Decks: Yes

E8
Echo of Input Data
RAM Structural System 16.00.00.28
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC

Layout Types:
TO ROOF
TO STEM WALL
Tables Selected:
Deck Table: ramdecks
Master Steel Table: ramaisc
Default Steel Table: ramaisc
Alternate Steel Table: ramaisc
Column Steel Table: ramaisc
Reinforcement Table: ramgb50010
Pan Form Table: ramceco
Story Data:
Level Story Label Layout Type Height (m)
2 TO ROOF TO ROOF 4.000
1 TO STEM WALL TO STEM WALL 1.000

Concrete Floor Properties:


ID Label Effect Thick f'c Unit Wt UW-Self Poisson's Bending Fac Diaph Fac
mm kg/cm2 kg/m3 kg/m3
1 ROOF SLAB 200.00 281.23 2322.68 2402.77 0.20 1.00 1.00

ID Angle f11 f22 f12 m11 m22 m12


1 --- --- --- --- --- --- ---

Load Properties:
Surface:
ID DL Constr DL LL Reduct. Partition Constr LL Mass DL
kg/m2 kg/m2 kg/m2 Type kg/m2 kg/m2 kg/m2
R-A1 300.0 50.0 102.0 Roof 0.0 0.0 300.0
R-A2 300.0 50.0 102.0 Roof 0.0 0.0 300.0
R-A3 320.0 50.0 102.0 Roof 0.0 0.0 320.0
R-A4 365.0 50.0 102.0 Roof 0.0 0.0 365.0

Line:
ID DL Constr DL LL Reduct. Partition Constr LL Mass DL
kg/m kg/m kg/m Type kg/m kg/m kg/m
DL: W @ Stem 2810.00 0.000 0.000 Unred. 0.000 0.000 1405.000
Wall 0
DL: V @ Stem 880.000 0.000 0.000 Unred. 0.000 0.000 440.000
Wall
DL:200Partiton 0.000 0.000 0.000 Unred. 0.000 0.000 880.000
@Roof
E9
Echo of Input Data
RAM Structural System 16.00.00.28 Page 2/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
ID DL Constr DL LL Reduct. Partition Constr LL Mass DL
DL: P + V 1130.00 0.000 0.000 Unred. 0.000 0.000 1570.000
0
DL: P + V + W 1130.00 0.000 0.000 Unred. 0.000 0.000 2535.000
0

BEAM SECTION PROPERTIES:


Concrete:
# Label Shape Depth Width Flange Web Cracked Factor
Overhang Thick Axial Flex Tors
mm
mm mm mm
1 B1 Rect 550.00 500.00 ---- ---- ---- 1.00 0.35 0.10
2 B2 Rect 550.00 600.00 ---- ---- ---- 1.00 0.35 0.10
COLUMN SECTION PROPERTIES:
Concrete:
# Label Shape Depth/Diam Width Cracked Factor
mm mm Axial Flex Tors
1 C1 Rect 400.00 400.00 1.00 0.70 1.00
Grid Systems:
System Label Type X Offset Y Offset Rotation
m m
Main Orthogonal 0.000 0.000 0.00
ALT Orthogonal 0.000 0.000 0.00
Roof Hatch Orthogonal 0.000 0.000 0.00
Grids:
System: Main
X Grids Label X Min Y Max Y
m m m
1 0.0000 ---- ----
2 4.3500 ---- ----
3 8.7000 ---- ----

Y Grids Label Y Min X Max X


m m m
A 0.0000 ---- ----
B 5.6000 ---- ----
C 11.2000 ---- ----

System: ALT
X Grids Label X Min Y Max Y
m m m
E10
Echo of Input Data
RAM Structural System 16.00.00.28 Page 3/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
X Grids Label X Min Y Max Y
1' 0.2000 ---- ----
3' 8.5000 ---- ----

Y Grids Label Y Min X Max X


m m m
A' 0.2000 ---- ----
C' 11.0000 ---- ----

System: Roof Hatch


X Grids Label X Min Y Max Y
m m m
W 6.1200 ---- ----
E 7.0340 ---- ----

Y Grids Label Y Min X Max X


m m m
S 3.4990 ---- ----
N 4.2600 ---- ----

DATA FOR FLOOR TYPE: TO ROOF


Grid Systems:
Main
ALT
Columns:
ID X Y Shape Orientation Param* LLRed Frame
m m Angle kg/cm2 % Type
1 0.200 0.200 Conc 0.00 281.2 Calc Gravity
2 0.200 5.600 Conc 0.00 281.2 Calc Gravity
3 0.200 11.000 Conc 0.00 281.2 Calc Gravity
4 4.350 0.200 Conc 0.00 281.2 Calc Gravity
5 4.350 11.000 Conc 0.00 281.2 Calc Gravity
6 8.500 0.200 Conc 0.00 281.2 Calc Gravity
7 8.500 5.600 Conc 0.00 281.2 Calc Gravity
8 8.500 11.000 Conc 0.00 281.2 Calc Gravity

* Parameter: Steel - Fy
Concrete - f'c
Other - E

Concrete Column Properties:


ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
(kg/m3) (kg/m3) Type (kg/cm2) (kg/cm2) Ratio (kg/cm2) (kg/cm2)
E11
Echo of Input Data
RAM Structural System 16.00.00.28 Page 4/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
1 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
2 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
3 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
4 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
5 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
6 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
7 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
8 2322.67 2402.77 NWC ---- Code 0.20 4218.42 4218.42
Beams:
ID Xi Yi Xj Yj Param* LLRed Type Frame User
m m m m kg/cm2 % Type Size
1 0.200 5.600 8.500 5.600 281.2 Calc Conc Gravity B2
2 0.250 0.250 0.250 5.600 281.2 Calc Conc Gravity B1
3 0.250 0.250 4.350 0.250 281.2 Calc Conc Gravity B1
6 4.350 10.950 8.450 10.950 281.2 Calc Conc Gravity B1
7 8.450 5.600 8.450 10.950 281.2 Calc Conc Gravity B1
14 4.350 5.600 4.350 11.000 281.2 Calc Conc Gravity B2
15 4.350 0.200 4.350 5.600 281.2 Calc Conc Gravity B2

* Parameter: Steel - Fy
Concrete - f'c
Other - E

Concrete Beam Properties:


ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear Defl
(kg/m3) (kg/m3) Type (kg/cm2) (kg/cm2) Ratio (kg/cm2) (kg/cm2) Criteria
1 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
2 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
3 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
6 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
7 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
14 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
15 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
Rigid Links:
Beam ID Left End Right End
Xb Yb Xs Ys Length Xb Yb Xs Ys Length
m m m m m m m m m m
2 0.250 0.250 0.200 0.200 0.071 0.250 5.600 0.200 5.600 0.050
3 0.250 0.250 0.200 0.200 0.071 4.350 0.250 4.350 0.200 0.050
6 4.350 10.950 4.350 11.000 0.050 8.450 10.950 8.500 11.000 0.071
7 8.450 5.600 8.500 5.600 0.050 8.450 10.950 8.500 11.000 0.071

E12
Echo of Input Data
RAM Structural System 16.00.00.28 Page 5/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC

Walls:
ID Xi Yi Xj Yj Frame Material LLRed
m m m m Type %
1 0.200 5.600 0.200 11.000 Lateral Concrete Calc
2 0.200 11.000 4.350 11.000 Lateral Concrete Calc
3 4.350 0.200 8.500 0.200 Lateral Concrete Calc
4 8.500 0.200 8.500 5.600 Lateral Concrete Calc
Concrete Wall Properties:
ID Pois UnitWt UW Self f'c Thick Ec
kg/m3 kg/m3 kg/cm2 mm kg/cm2
1 0.20 2322.68 2402.770 281.230 200.000 Calc
0
2 0.20 2322.68 2402.770 281.230 200.000 Calc
0
3 0.20 2322.68 2402.770 281.230 200.000 Calc
0
4 0.20 2322.68 2402.770 281.230 200.000 Calc
0

Wall Openings:
Wall # Opening # Reference Corner X Y Width Height
m m m m
1 1 Lower Left 2.750 1.800 1.300 1.000

Slab Edges:
Xi Yi Xj Yj Edge Dist
m m m m mm
Diaphragm 1:
0.000 11.200 8.700 11.200 0.0
8.700 0.000 8.700 11.200 0.0
0.000 0.000 8.700 0.000 0.0
0.000 0.000 0.000 11.200 0.0
Slab Openings:
Xi Yi Xj Yj Edge Dist
m m m m mm
6.120 3.499 7.034 3.499 0.0
7.034 3.499 7.034 4.260 0.0
6.120 4.260 7.034 4.260 0.0
6.120 3.499 6.120 4.260 0.0
Deck Polygons:

E13
Echo of Input Data
RAM Structural System 16.00.00.28 Page 6/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
Deck Prop Slab Action Angle X-Coord Y-Coord
Type ID m m
Concrete 1 Two-Way -- 0.00 0.00
0.00 11.20
8.70 11.20
8.70 0.00
0.00 0.00
Load Polygons:
Load Properties ID X-Coord Y-Coord
m m
R-A1 0.00 0.00
0.00 1.40
8.70 1.40
8.70 0.00
0.00 0.00
R-A1 0.00 11.20
8.70 11.20
8.70 9.80
0.00 9.80
0.00 11.20
R-A2 0.00 8.40
0.00 9.80
8.70 9.80
8.70 8.40
0.00 8.40
R-A2 0.00 2.80
8.70 2.80
8.70 1.40
0.00 1.40
0.00 2.80
R-A3 0.00 4.20
8.70 4.20
8.70 2.80
0.00 2.80
0.00 4.20
R-A3 0.00 8.40
0.00 7.00
8.70 7.00
8.70 8.40
0.00 8.40
R-A4 0.00 4.20
0.00 7.00
8.70 7.00
8.70 4.20
0.00 E14 4.20
Echo of Input Data
RAM Structural System 16.00.00.28 Page 7/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC

User Input Line Loads:


Load Properties ID Xi Yi Xj Yj
m m m m
DL:200Partiton@Roof 5.89 0.20 5.89 11.00
DL: P + V + W 4.35 10.95 8.45 10.95
DL: P + V + W 8.45 5.60 8.45 10.95
DL: P + V + W 0.25 0.25 4.35 0.25
DL: P + V + W 0.25 0.25 0.25 5.60
DL: P + V 0.20 5.60 0.20 11.00
DL: P + V 0.20 11.00 4.35 11.00
DL: P + V 8.50 0.20 8.50 5.60
DL: P + V 4.35 0.20 8.50 0.20

DATA FOR FLOOR TYPE: TO STEM WALL


Grid Systems:
Main
ALT
Columns:
ID X Y Shape Orientation Param* LLRed Frame
m m Angle kg/cm2 % Type
1 4.350 11.000 Conc 0.00 281.2 Calc Gravity
2 0.200 11.000 Conc 0.00 281.2 Calc Gravity
3 8.500 11.000 Conc 0.00 281.2 Calc Gravity
4 8.500 5.600 Conc 0.00 281.2 Calc Gravity
5 0.200 5.600 Conc 0.00 281.2 Calc Gravity
6 0.200 0.200 Conc 0.00 281.2 Calc Gravity
7 4.350 0.200 Conc 0.00 281.2 Calc Gravity
8 8.500 0.200 Conc 0.00 281.2 Calc Gravity

* Parameter: Steel - Fy
Concrete - f'c
Other - E

Concrete Column Properties:


ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
(kg/m3) (kg/m3) Type (kg/cm2) (kg/cm2) Ratio (kg/cm2) (kg/cm2)
1 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
2 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
3 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
4 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
5 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
6 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
7 2322.68 2402.77 NWC ---- E15 Code 0.20 4218.42 4218.42
Echo of Input Data
RAM Structural System 16.00.00.28 Page 8/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
ID UW UW Self Conc fct Ec Poisson fy Long fyt Shear
8 2322.68 2402.77 NWC ---- Code 0.20 4218.42 4218.42
Walls:
ID Xi Yi Xj Yj Frame Material LLRed
m m m m Type %
1 0.200 11.000 4.350 11.000 Lateral Concrete Calc
2 0.200 5.600 0.200 11.000 Lateral Concrete Calc
3 4.350 0.200 8.500 0.200 Lateral Concrete Calc
4 8.500 0.200 8.500 5.600 Lateral Concrete Calc
5 4.350 11.000 8.500 11.000 Gravity Concrete Calc
6 8.500 5.600 8.500 11.000 Gravity Concrete Calc
7 0.200 0.200 4.350 0.200 Gravity Concrete Calc
8 0.200 0.200 0.200 5.600 Gravity Concrete Calc
Concrete Wall Properties:
ID Pois UnitWt UW Self f'c Thick Ec
kg/m3 kg/m3 kg/cm2 mm kg/cm2
1 0.20 2322.68 2402.770 281.230 400.000 Calc
0
2 0.20 2322.68 2402.770 281.230 400.000 Calc
0
3 0.20 2322.68 2402.770 281.230 400.000 Calc
0
4 0.20 2322.68 2402.770 281.230 400.000 Calc
0
5 0.20 2322.68 2402.770 281.230 400.000 Calc
0
6 0.20 2322.68 2402.770 281.230 400.000 Calc
0
7 0.20 2322.68 2402.770 281.230 400.000 Calc
0
8 0.20 2322.68 2402.770 281.230 400.000 Calc
0

User Input Line Loads:


Load Properties ID Xi Yi Xj Yj
m m m m
DL: W @ Stem Wall 4.35 11.00 8.50 11.00
DL: W @ Stem Wall 8.50 5.60 8.50 11.00
DL: W @ Stem Wall 0.20 0.20 4.35 0.20
DL: W @ Stem Wall 0.20 0.20 0.20 5.60
DL: V @ Stem Wall 0.20 11.00 4.35 11.00
DL: V @ Stem Wall 0.20 5.60 0.20 11.00
DL: V @ Stem Wall 8.50 E16 0.20 8.50 5.60
Echo of Input Data
RAM Structural System 16.00.00.28 Page 9/9
John Rodrigues
RSLF - AB
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
Load Properties ID Xi Yi Xj Yj
DL: V @ Stem Wall 4.35 0.20 8.50 0.20

E17
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:32:35

E18
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:33:00

E19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:39:44

ELEVATION @ GRIDLINE 1'

E20
A' B C'
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:41:30

ELEVATION @ GRIDLINE 3'

E21
A' B C'
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:42:56

ELEVATION @ GRIDLINE A'

E22
1' 3'
2
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/2019 14:44:50

ELEVATION @ GRIDLINE C'

E23
1' 2 3'
RAM Structural System V16.00.00.28. - Floor Plan: TO STEM WALL
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3

C
C'

A'
A
1' 3'

E24
RAM Structural System V16.00.00.28. - Floor Plan: TO STEM WALL
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3
DL: V @ Stem Wall DL: W @ Stem Wall C
C'

DL: W @ Stem Wall


DL: V @ Stem Wall

B
DL: W @ Stem Wall

DL: V @ Stem Wall

DL: W @ Stem Wall DL: V @ Stem Wall


A'
A
1' 3'

E25
RAM Structural System V16.00.00.28. - Floor Plan: TO ROOF
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3

C
C'

A'
A
1' 3'

E26
RAM Structural System V16.00.00.28. - Floor Plan: TO ROOF
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3

C
C'

ROOF SLAB
B

A'
A
1' 3'

E27
RAM Structural System V16.00.00.28. - Floor Plan: TO ROOF
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3

C
C'
R-A1

R-A2

R-A3

R-A4
B

R-A3

R-A2

R-A1

A'
A
1' 3'

E28
RAM Structural System V16.00.00.28. - Floor Plan: TO ROOF
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

1 2 3
DL: P + V DL: P + V + W C
C'

DL: P + V + W
DL: P + V

DL:200Partiton@Roof
B
DL: P + V + W

DL: P + V

DL: P + V + W DL: P + V
A'
A
1' 3'

E29
Criteria, Mass and Exposure Data
RAM Frame 16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

CRITERIA:
Rigid End Zones: Ignore Effects
Member Force Output: At Face of Joint
P-Delta: Yes Scale Factor: 1.00
Ground Level: TO STEM WALL
Mesh Criteria :
Max. Distance Between Nodes on Mesh Line (m) : 1.50
Merge Node Tolerance (mm) : 0.2500
Geometry Tolerance (mm) : 0.1250
Walls Out-of-plane Stiffness Not Included in Analysis.
Sign considered for Dynamic Load Case Results.
Rigid Links Included at Fixed Beam-to-Wall Locations
Eigenvalue Analysis : Eigen Vectors (Subspace Iteration)
DIAPHRAGM DATA:
Story Diaph # Diaph Type
TO ROOF 1 Rigid

Disconnect Internal Nodes of Beams: Yes


Disconnect Nodes outside Slab Boundary: Yes

Semirigid Diaphragm Parameters:


Use Slab Edges for Exterior Boundary
Calculate Diaphragm Mass
Hard Node Density Factor: 1.00
STORY MASS DATA:
Includes Self Mass of:
Beams
Columns (Half mass of columns above and below)
Walls (Half mass of walls above and below)
Slabs/Deck

Calculated Values:
Story Diaph # Weight Mass MMI Xm Ym EccX EccY
kg 1000kg 1000kg- m m m m
m2
TO ROOF 1 216.44 216.44 4986 4.42 5.60 0.43 0.56
TO STEM WALL None 79.45 79.45 2450 4.36 5.60 -- --

Story Diaph # Combine


TO ROOF 1 None
TO STEM WALL None 1-TO ROOF
Combined/Merged Values:
Story Diaph # Weight Mass MMI Xm Ym EccX EccY
1000kg 1000kg 1000kg- m m m m
m2
E30
Criteria, Mass and Exposure Data
RAM Frame 16.00.00.28 Page 2/2
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Story Diaph # Weight Mass MMI Xm Ym EccX EccY
TO ROOF 1 295.9 295.89 7435 4.40 5.60 0.43 0.56

Distributed Mass Values for Pseudo-Flexible or Meshed Diaphragms:


Story Diaph # Total Weight Total Mass
kg 1000kg
TO ROOF 1 216.44 216.438

WIND EXPOSURE DATA:


Calculated Values:
Story Diaph # Building Extents (m) Expose Parapet
Min X Max X Min Y Max Y m
TO ROOF 1 0.00 8.70 -0.00 11.20 Full 1.60
STORY GRAVITY LOADS DATA:
Includes Weight of:
Beams
Columns
Walls
Slabs/Deck

Live Load Reduction (Calculated)


Reducible : 0.00 %
Storage : 0.00 %
Roof : 0.00 %

Calculated Values:
Story Diaph # Dead Xc Yc Live Xc Yc
kg m m kg m m
TO ROOF 1 196533.19 4.36 5.60 0.00 0.00 0.00
TO STEM WALL None 110268.88 4.35 5.60 0.00 0.00 0.00

Story Diaph # Roof Xc Yc Combine


kg m m
TO ROOF 1 9867.98 4.33 5.61 None
TO STEM WALL None 0.00 0.00 0.00 1-TO
ROOF

User Specified Values:


Story Diaph # Dead Xc Yc Live Xc Yc
kg m m kg m m
TO ROOF 1 306802.07 4.35 5.60 0.00 0.00 0.00

Story Diaph # Roof Xc Yc


kg m m
TO ROOF 1 9868.0 4.33 5.61
E31
Frame Model Data
RAM Frame 16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

STORY DATA:
Level Story Label Layout Type Height
m
2 TO ROOF TO ROOF 4.00
1 TO STEM WALL TO STEM WALL 1.00

COLUMN SECTION PROPERTIES:


Concrete:
# Label Shape Depth/Diam Width Cracked Factors
mm mm Bending Axial Torsion
1 C1 Rectangle 400.00 400.00 0.70 1.00 1.00
BEAM SECTION PROPERTIES:
Concrete:
# Label Shape Depth Width Flange Web-Thk
Overhang Thickness
mm mm mm mm
1 B1 Rectangle 550.00 500.00 ---- ---- ----
2 B2 Rectangle 550.00 600.00 ---- ---- ----

# Label Cracked Factors


Bending Axial Torsion
1 B1 0.35 1.00 0.10
2 B2 0.35 1.00 0.10
FRAME MEMBERS
Frame #0:
Level: TO ROOF

Concrete Wall:
# X Y Z Pois UnitWt UW Self f'c Thick Group
m m m kg/m3 kg/m3 kg/cm2
1 0.200 5.600 5.000 0.20 2322.7 2402.8 281.230 200.0 0
0.200 11.000 5.000
0.200 5.600 1.000
0.200 11.000 1.000
2 0.200 11.000 5.000 0.20 2322.7 2402.8 281.230 200.0 0
4.350 11.000 5.000
0.200 11.000 1.000
4.350 11.000 1.000
3 4.350 0.200 5.000 0.20 2322.7 2402.8 281.230 200.0 0
8.500 0.200 5.000
4.350 0.200 1.000
8.500 0.200 1.000
4 8.500 0.200 5.000 0.20 2322.7 2402.8 281.230 200.0 0
8.500 5.600 5.000
E32
Frame Model Data
RAM Frame 16.00.00.28 Page 2/6
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
8.500 0.200 1.000
8.500 5.600 1.000

Wall Openings:
Wall # Opening # Reference Corner X Y Width Height
m m mm mm
1 1 Lower Left 2.750 1.800 1300.000 1000.000

Wall Crack Factors:


Wall # Membrane Bending
1 0.350 1.000
2 0.350 1.000
3 0.350 1.000
4 0.350 1.000
Level: TO STEM WALL

Concrete Wall:
# X Y Z Pois UnitWt UW Self f'c Thick Group
m m m kg/m3 kg/m3 kg/cm2
1 0.200 11.000 1.000 0.20 2322.7 2402.8 281.230 400.0 0
4.350 11.000 1.000
0.200 11.000 0.000
4.350 11.000 0.000
2 0.200 5.600 1.000 0.20 2322.7 2402.8 281.230 400.0 0
0.200 11.000 1.000
0.200 5.600 0.000
0.200 11.000 0.000
3 4.350 0.200 1.000 0.20 2322.7 2402.8 281.230 400.0 0
8.500 0.200 1.000
4.350 0.200 0.000
8.500 0.200 0.000
4 8.500 0.200 1.000 0.20 2322.7 2402.8 281.230 400.0 0
8.500 5.600 1.000
8.500 0.200 0.000
8.500 5.600 0.000

Wall Crack Factors:


Wall # Membrane Bending
1 0.350 1.000
2 0.350 1.000
3 0.350 1.000
4 0.350 1.000
GRAVITY WALL AND GRAVITY COLUMN SPRING PROPERTIES
Node # Kx Ky Kz Krx Kry Krx Angle
kg/m kg/m kg/m kg.m/rad kg.m/rad kg.m/rad
E33
Frame Model Data
RAM Frame 16.00.00.28 Page 3/6
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Node # Kx Ky Kz Krx Kry Krx Angle
1 __ __ 10248363 __ __ __ 0.00
0.30
8 __ __ 10248363 __ __ __ 0.00
0.30

NODES:
# X Y Z Fdtn Diaphr
m m m (Diaph.# - Story Name)
1 0.200 0.200 5.000 N 1 - TO ROOF
2 0.200 5.600 5.000 N 1 - TO ROOF
3 0.200 11.000 5.000 N 1 - TO ROOF
4 4.350 0.200 5.000 N 1 - TO ROOF
5 4.350 11.000 5.000 N 1 - TO ROOF
6 8.500 0.200 5.000 N 1 - TO ROOF
7 8.500 5.600 5.000 N 1 - TO ROOF
8 8.500 11.000 5.000 N 1 - TO ROOF
9 0.200 0.200 1.000 N None
10 0.200 5.600 1.000 N None
11 0.200 11.000 1.000 N None
12 4.350 0.200 1.000 N None
13 4.350 11.000 1.000 N None
14 8.500 0.200 1.000 N None
15 8.500 5.600 1.000 N None
16 8.500 11.000 1.000 N None
17 0.200 0.200 0.000 Y --
18 0.200 5.600 0.000 Y --
19 0.200 11.000 0.000 Y --
20 4.350 0.200 0.000 Y --
21 4.350 11.000 0.000 Y --
22 8.500 0.200 0.000 Y --
23 8.500 5.600 0.000 Y --
24 8.500 11.000 0.000 Y --
25 0.200 10.206 4.294 N None
26 0.200 9.296 4.342 N None
27 0.200 9.650 5.000 N 1 - TO ROOF
28 0.200 9.650 1.000 N None
29 0.200 9.372 1.884 N None
30 0.200 10.099 1.865 N None
31 0.200 7.558 4.142 N None
32 0.200 8.300 5.000 N 1 - TO ROOF
33 0.200 6.711 4.125 N None
34 0.200 6.950 5.000 N 1 - TO ROOF
35 0.200 11.000 4.000 N None
36 0.200 10.272 3.620 N None
37 0.200 6.512 3.124 N
E34 None
Frame Model Data
RAM Frame 16.00.00.28 Page 4/6
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
# X Y Z Fdtn Diaphr
38 0.200 5.600 3.000 N None
39 0.200 6.683 1.940 N None
40 0.200 5.600 2.000 N None
41 0.200 7.969 2.907 N None
42 0.200 7.388 3.168 N None
43 0.200 8.109 2.432 N None
44 0.200 7.521 2.058 N None
45 0.200 7.976 3.993 N None
46 0.200 7.914 3.577 N None
47 0.200 8.115 3.258 N None
48 0.200 10.338 2.950 N None
49 0.200 9.650 2.800 N None
50 0.200 10.463 2.325 N None
51 0.200 8.641 4.336 N None
52 0.200 8.350 3.800 N None
53 0.200 9.000 3.800 N None
54 0.200 9.650 3.800 N None
55 0.200 9.000 2.800 N None
56 0.200 8.350 2.800 N None
57 0.200 8.573 2.065 N None
58 0.200 8.300 1.000 N None
59 0.200 5.600 4.000 N None
60 0.200 9.650 3.300 N None
61 0.200 11.000 3.000 N None
62 0.200 6.950 1.000 N None
63 0.200 8.350 3.300 N None
64 0.200 11.000 2.000 N None
65 1.237 11.000 2.000 N None
66 1.237 11.000 1.000 N None
67 1.237 11.000 3.000 N None
68 1.237 11.000 4.000 N None
69 1.237 11.000 5.000 N 1 - TO ROOF
70 2.275 11.000 2.000 N None
71 2.275 11.000 1.000 N None
72 2.275 11.000 3.000 N None
73 2.275 11.000 4.000 N None
74 2.275 11.000 5.000 N 1 - TO ROOF
75 3.312 11.000 2.000 N None
76 3.312 11.000 1.000 N None
77 3.312 11.000 3.000 N None
78 3.312 11.000 4.000 N None
79 3.312 11.000 5.000 N 1 - TO ROOF
80 4.350 11.000 2.000 N None
81 4.350 11.000 3.000 N None
82 4.350 11.000 4.000 N None
E35
Frame Model Data
RAM Frame 16.00.00.28 Page 5/6
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
# X Y Z Fdtn Diaphr
83 4.350 0.200 2.000 N None
84 5.387 0.200 2.000 N None
85 5.387 0.200 1.000 N None
86 4.350 0.200 3.000 N None
87 5.387 0.200 3.000 N None
88 4.350 0.200 4.000 N None
89 5.387 0.200 4.000 N None
90 5.387 0.200 5.000 N 1 - TO ROOF
91 6.425 0.200 2.000 N None
92 6.425 0.200 1.000 N None
93 6.425 0.200 3.000 N None
94 6.425 0.200 4.000 N None
95 6.425 0.200 5.000 N 1 - TO ROOF
96 7.462 0.200 2.000 N None
97 7.462 0.200 1.000 N None
98 7.462 0.200 3.000 N None
99 7.462 0.200 4.000 N None
100 7.462 0.200 5.000 N 1 - TO ROOF
101 8.500 0.200 2.000 N None
102 8.500 0.200 3.000 N None
103 8.500 0.200 4.000 N None
104 8.500 1.550 2.000 N None
105 8.500 1.550 1.000 N None
106 8.500 1.550 3.000 N None
107 8.500 1.550 4.000 N None
108 8.500 1.550 5.000 N 1 - TO ROOF
109 8.500 2.900 2.000 N None
110 8.500 2.900 1.000 N None
111 8.500 2.900 3.000 N None
112 8.500 2.900 4.000 N None
113 8.500 2.900 5.000 N 1 - TO ROOF
114 8.500 4.250 2.000 N None
115 8.500 4.250 1.000 N None
116 8.500 4.250 3.000 N None
117 8.500 4.250 4.000 N None
118 8.500 4.250 5.000 N 1 - TO ROOF
119 8.500 5.600 2.000 N None
120 8.500 5.600 3.000 N None
121 8.500 5.600 4.000 N None
122 0.200 11.000 0.500 N None
123 1.237 11.000 0.500 N None
124 1.237 11.000 0.000 Y --
125 2.275 11.000 0.500 N None
126 2.275 11.000 0.000 Y --
127 3.312 11.000 0.500 N None
E36
Frame Model Data
RAM Frame 16.00.00.28 Page 6/6
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
# X Y Z Fdtn Diaphr
128 3.312 11.000 0.000 Y --
129 4.350 11.000 0.500 N None
130 0.200 5.600 0.500 N None
131 0.200 6.950 0.500 N None
132 0.200 6.950 0.000 Y --
133 0.200 8.300 0.500 N None
134 0.200 8.300 0.000 Y --
135 0.200 9.650 0.500 N None
136 0.200 9.650 0.000 Y --
137 4.350 0.200 0.500 N None
138 5.387 0.200 0.500 N None
139 5.387 0.200 0.000 Y --
140 6.425 0.200 0.500 N None
141 6.425 0.200 0.000 Y --
142 7.462 0.200 0.500 N None
143 7.462 0.200 0.000 Y --
144 8.500 0.200 0.500 N None
145 8.500 1.550 0.500 N None
146 8.500 1.550 0.000 Y --
147 8.500 2.900 0.500 N None
148 8.500 2.900 0.000 Y --
149 8.500 4.250 0.500 N None
150 8.500 4.250 0.000 Y --
151 8.500 5.600 0.500 N None

E37
Exposure Boundaries
RAM Frame 16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

Profile X-Axis

2
TO ROOF - Diaph #1
1
Base
Zone Start (m) End (m) Height (m)
1 0.0000 8.7000 4.0000
2 0.0000 8.7000 1.6000 Parapet

E38
Exposure Boundaries
RAM Frame 16.00.00.28 Page 2/2
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

Profile Y-Axis

2
TO ROOF - Diaph #1
1
Base
Zone Start (m) End (m) Height (m)
1 -0.0000 11.2000 4.0000
2 -0.0000 11.2000 1.6000 Parapet

E39
Loads and Applied Forces
RAM Frame 16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

LOAD CASE: Wind


Wind ASCE 7-10
Exposure: C
Basic Wind Speed (km/h): 185.0
Apply Directionality Factor, Kd = 0.85
Use Topography Factor, Kzt: 1.00
Use Calculated Frequency for X-Dir.
Use Calculated Frequency for Y-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for X-Dir.
Gust Factor for Rigid Structures, G: Use G = 0.85 for Y-Dir.
Damping Ratio for Flexible Structures= 0.01
Mean Roof Height (m): Top Story Height + Parapet = 5.60
Ground Level: TO STEM WALL
WIND PRESSURES:
X-Direction: Natural Frequency = 6.709 Structure is Rigid
Y-Direction: Natural Frequency = 9.288 Structure is Rigid
CpWindward = 0.80 qLeeward (qh) = 124.37 kg/m2
GCpn (Parapet): Windward = 1.50 Leeward = -1.00
Height Kz Kzt qz Gust Factor G CpLeeward Pressure (kg/m2)
m kg/m2 X Y X Y X Y
5.60 0.886 1.000 124.374 ---- ---- ---- ---- 310.935 310.935
4.00 0.849 1.000 119.175 0.850 0.850 -0.500 -0.443 133.898 127.822
0.00 0.849 1.000 119.175 0.850 0.850 -0.500 -0.443 133.898 127.822

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_1_X
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 8571.32 0.00 4.35 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_1_X
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 8571.32 0.00
_________ _________
8571.32 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_1_Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
E40
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 2/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
TO ROOF 1 4.00 0.00 6552.36 4.35 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_1_Y
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 0.00 6552.36
_________ _________
0.00 6552.36

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_X+E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 6428.49 0.00 4.35 7.28

APPLIED STORY FORCES


Type: Wind_ASCE710_2_X+E
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 6428.49 0.00
_________ _________
6428.49 0.00

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_X-E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 6428.49 0.00 4.35 3.92

APPLIED STORY FORCES


Type: Wind_ASCE710_2_X-E
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 6428.49 0.00
_________ _________
6428.49 0.00

E41
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 3/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_Y+E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 0.00 4914.27 5.66 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_2_Y+E
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 0.00 4914.27
_________ _________
0.00 4914.27

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_2_Y-E
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 0.00 4914.27 3.05 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_2_Y-E
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 0.00 4914.27
_________ _________
0.00 4914.27

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_3_X+Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 6428.49 4914.27 4.35 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_3_X+Y
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 6428.49 E42 4914.27
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 4/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
_________ _________
6428.49 4914.27

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_3_X-Y
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 6428.49 -4914.27 4.35 5.60

APPLIED STORY FORCES


Type: Wind_ASCE710_3_X-Y
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 6428.49 -4914.27
_________ _________
6428.49 -4914.27

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X+Y_CW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 4821.37 3685.70 3.05 7.28

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X+Y_CW
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 4821.37 3685.70
_________ _________
4821.37 3685.70

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X+Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 4821.37 3685.70 5.66 3.92

E43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 5/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X+Y_CCW
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 4821.37 3685.70
_________ _________
4821.37 3685.70

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X-Y_CW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 4821.37 -3685.70 5.66 7.28

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X-Y_CW
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 4821.37 -3685.70
_________ _________
4821.37 -3685.70

APPLIED DIAPHRAGM FORCES


Type: Wind_ASCE710_4_X-Y_CCW
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 4821.37 -3685.70 3.05 3.92

APPLIED STORY FORCES


Type: Wind_ASCE710_4_X-Y_CCW
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 4821.37 -3685.70
_________ _________
4821.37 -3685.70

E44
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 6/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

LOAD CASE: Seismic


Seismic ASCE 7-10 Equivalent Lateral Force
Site Class: D Importance Factor: 1.50 Ss: 0.370 g S1: 0.170 g TL: 12.00 s
Fa: 1.504 Fv: 2.120 SDs: 0.371 g SD1: 0.240 g
Occupancy Category: IV Seismic Design Category: D
Provisions for: Force
Ground Level: TO STEM WALL

Dir Eccent R Ta Equation Building Period-T


X + And - 5.0 Std,Ct=0.020,x=0.75 Use Ta
Y + And - 5.0 Std,Ct=0.020,x=0.75 Use Ta

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
X 0.138 1.460 0.138 0.138 0.111 0.523 0.024 0.111 1.000

Dir Ta Cu T T-used Cs Cs(max) Cs(min) Cs-used k


Eq12.8-2 Eq12.8-3 Eq12.8-5
Y 0.138 1.460 0.138 0.138 0.111 0.523 0.024 0.111 1.000

Total Building Weight (kg) = 216612.52

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 0.00 4.40 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 0.00
_________ _________
24108.11 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 0.00 4.40 5.04

E45
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 7/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 0.00
_________ _________
24108.11 0.00

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 0.00 24108.11 4.84 5.60

APPLIED STORY FORCES


Type: EQ_ASCE710_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 0.00 24108.11
_________ _________
0.00 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 0.00 24108.11 3.97 5.60

APPLIED STORY FORCES


Type: EQ_ASCE710_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 0.00 24108.11
_________ _________
0.00 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_0.3Y_+E_F
Level Diaph.# Ht E46 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 8/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
m kg kg m m
TO ROOF 1 4.00 24108.11 7232.43 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 7232.43
_________ _________
24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 -7232.43 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 -7232.43
_________ _________
24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 7232.43 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 7232.43
_________ _________
-24108.11 7232.43
E47
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 9/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 -7232.43 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 -7232.43
_________ _________
-24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 24108.11 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 24108.11
_________ _________
7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 -24108.11 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 E48-24108.11
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 10/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
_________ _________
7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 24108.11 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 24108.11
_________ _________
-7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 -24108.11 4.84 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 -24108.11
_________ _________
-7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 7232.43 3.97 6.16

E49
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 11/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 7232.43
_________ _________
24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 -7232.43 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 -7232.43
_________ _________
24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 7232.43 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 7232.43
_________ _________
-24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_-E_F
Level Diaph.# Ht E50 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 12/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
m kg kg m m
TO ROOF 1 4.00 -24108.11 -7232.43 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_+E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 -7232.43
_________ _________
-24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 24108.11 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 24108.11
_________ _________
7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 -24108.11 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 -24108.11
_________ _________
7232.43 -24108.11
E51
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 13/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 24108.11 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 24108.11
_________ _________
-7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 -24108.11 3.97 6.16

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_+E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 -24108.11
_________ _________
-7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 7232.43 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 E52 7232.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 14/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
_________ _________
24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 -7232.43 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 -7232.43
_________ _________
24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 7232.43 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 7232.43
_________ _________
-24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 -7232.43 4.84 5.04

E53
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 15/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 -7232.43
_________ _________
-24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 24108.11 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 24108.11
_________ _________
7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 -24108.11 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 -24108.11
_________ _________
7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_+E_F
Level Diaph.# Ht E54 Fx Fy X Y
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 16/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
m kg kg m m
TO ROOF 1 4.00 -7232.43 24108.11 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 24108.11
_________ _________
-7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_+E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 -24108.11 4.84 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_+E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 -24108.11
_________ _________
-7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 7232.43 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 7232.43
_________ _________
24108.11 7232.43
E55
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 17/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 24108.11 -7232.43 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 24108.11 -7232.43
_________ _________
24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 7232.43 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 7232.43
_________ _________
-24108.11 7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -24108.11 -7232.43 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-X_-E_-0.3Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -24108.11 E56 -7232.43
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 18/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
_________ _________
-24108.11 -7232.43

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 24108.11 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 24108.11
_________ _________
7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 7232.43 -24108.11 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 7232.43 -24108.11
_________ _________
7232.43 -24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 24108.11 3.97 5.04

E57
Loads and Applied Forces
RAM Frame 16.00.00.28 Page 19/19
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 24108.11
_________ _________
-7232.43 24108.11

APPLIED DIAPHRAGM FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_-E_F
Level Diaph.# Ht Fx Fy X Y
m kg kg m m
TO ROOF 1 4.00 -7232.43 -24108.11 3.97 5.04

APPLIED STORY FORCES


Type: EQ_ASCE710_-0.3X_-E_-Y_-E_F
Level Ht Fx Fy
m kg kg
TO ROOF 4.00 -7232.43 -24108.11
_________ _________
-7232.43 -24108.11

E58
Story Displacements
RAM Frame 16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC

CRITERIA:
Rigid End Zones: Ignore Effects
Member Force Output: At Face of Joint
P-Delta: Yes Scale Factor: 1.00
Ground Level: TO STEM WALL
Mesh Criteria :
Max. Distance Between Nodes on Mesh Line (m) : 1.50
Merge Node Tolerance (mm) : 0.2500
Geometry Tolerance (mm) : 0.1250
Walls Out-of-plane Stiffness Not Included in Analysis.
Sign considered for Dynamic Load Case Results.
Rigid Links Included at Fixed Beam-to-Wall Locations
Eigenvalue Analysis : Eigen Vectors (Subspace Iteration)
LOAD CASE DEFINITIONS:
D DeadLoad RAMUSER
Rfp PosRoofLiveLoad RAMUSER
W1 Wind Wind_ASCE710_1_X
W2 Wind Wind_ASCE710_1_Y
W3 Wind Wind_ASCE710_2_X+E
W4 Wind Wind_ASCE710_2_X-E
W5 Wind Wind_ASCE710_2_Y+E
W6 Wind Wind_ASCE710_2_Y-E
W7 Wind Wind_ASCE710_3_X+Y
W8 Wind Wind_ASCE710_3_X-Y
W9 Wind Wind_ASCE710_4_X+Y_CW
W10 Wind Wind_ASCE710_4_X+Y_CCW
W11 Wind Wind_ASCE710_4_X-Y_CW
W12 Wind Wind_ASCE710_4_X-Y_CCW
E1 Seismic EQ_ASCE710_X_+E_F
E2 Seismic EQ_ASCE710_X_-E_F
E3 Seismic EQ_ASCE710_Y_+E_F
E4 Seismic EQ_ASCE710_Y_-E_F
E5 Seismic EQ_ASCE710_X_+E_0.3Y_+E_F
E6 Seismic EQ_ASCE710_X_+E_-0.3Y_+E_F
E7 Seismic EQ_ASCE710_-X_+E_0.3Y_+E_F
E8 Seismic EQ_ASCE710_-X_+E_-0.3Y_+E_F
E9 Seismic EQ_ASCE710_0.3X_+E_Y_+E_F
E10 Seismic EQ_ASCE710_0.3X_+E_-Y_+E_F
E11 Seismic EQ_ASCE710_-0.3X_+E_Y_+E_F
E12 Seismic EQ_ASCE710_-0.3X_+E_-Y_+E_F
E13 Seismic EQ_ASCE710_X_+E_0.3Y_-E_F
E14 Seismic EQ_ASCE710_X_+E_-0.3Y_-E_F
E15 Seismic EQ_ASCE710_-X_+E_0.3Y_-E_F
E16 Seismic EQ_ASCE710_-X_+E_-0.3Y_-E_F
E17 Seismic EQ_ASCE710_0.3X_+E_Y_-E_F
E59
Story Displacements
RAM Frame 16.00.00.28 Page 2/3
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
E18 Seismic EQ_ASCE710_0.3X_+E_-Y_-E_F
E19 Seismic EQ_ASCE710_-0.3X_+E_Y_-E_F
E20 Seismic EQ_ASCE710_-0.3X_+E_-Y_-E_F
E21 Seismic EQ_ASCE710_X_-E_0.3Y_+E_F
E22 Seismic EQ_ASCE710_X_-E_-0.3Y_+E_F
E23 Seismic EQ_ASCE710_-X_-E_0.3Y_+E_F
E24 Seismic EQ_ASCE710_-X_-E_-0.3Y_+E_F
E25 Seismic EQ_ASCE710_0.3X_-E_Y_+E_F
E26 Seismic EQ_ASCE710_0.3X_-E_-Y_+E_F
E27 Seismic EQ_ASCE710_-0.3X_-E_Y_+E_F
E28 Seismic EQ_ASCE710_-0.3X_-E_-Y_+E_F
E29 Seismic EQ_ASCE710_X_-E_0.3Y_-E_F
E30 Seismic EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 Seismic EQ_ASCE710_-X_-E_0.3Y_-E_F
E32 Seismic EQ_ASCE710_-X_-E_-0.3Y_-E_F
E33 Seismic EQ_ASCE710_0.3X_-E_Y_-E_F
E34 Seismic EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 Seismic EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 Seismic EQ_ASCE710_-0.3X_-E_-Y_-E_F

Level: TO ROOF, Diaph: 1


Center of Mass (m): (4.42, 5.60)
LdC Disp X Disp Y Theta Z
mm mm rad
D -0.00350 0.00672 -0.00000
Rfp -0.00027 0.00052 -0.00000
W1 0.14361 -0.03137 0.00000
W2 -0.02398 0.07589 -0.00000
W3 0.10768 -0.02243 -0.00000
W4 0.10774 -0.02463 0.00000
W5 -0.01797 0.05626 0.00000
W6 -0.01801 0.05757 -0.00000
W7 0.08972 0.03339 -0.00000
W8 0.12570 -0.08044 0.00000
W9 0.06726 0.02635 -0.00000
W10 0.06733 0.02373 0.00000
W11 0.09424 -0.05902 -0.00000
W12 0.09431 -0.06165 0.00000
E1 0.40390 -0.08687 -0.00000
E2 0.40398 -0.08962 0.00000
E3 -0.08821 0.27801 -0.00000
E4 -0.08827 0.28014 -0.00000
E5 0.37743 -0.00347 -0.00000
E6 0.43036 -0.17027 -0.00000
E7 -0.43036 0.17027 0.00000
E8 -0.37743 E60
0.00347 0.00000
Story Displacements
RAM Frame 16.00.00.28 Page 3/3
John Rodrigues
DataBase: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC
E9 0.03296 0.25195 -0.00000
E10 0.20938 -0.30407 -0.00000
E11 -0.20938 0.30407 0.00000
E12 -0.03296 -0.25195 0.00000
E13 0.37742 -0.00283 -0.00000
E14 0.43038 -0.17091 -0.00000
E15 -0.43038 0.17091 0.00000
E16 -0.37742 0.00283 0.00000
E17 0.03290 0.25408 -0.00001
E18 0.20944 -0.30620 0.00000
E19 -0.20944 0.30620 -0.00000
E20 -0.03290 -0.25408 0.00001
E21 0.37751 -0.00621 0.00000
E22 0.43044 -0.17302 0.00000
E23 -0.43044 0.17302 -0.00000
E24 -0.37751 0.00621 -0.00000
E25 0.03298 0.25112 0.00000
E26 0.20941 -0.30489 0.00000
E27 -0.20941 0.30489 -0.00000
E28 -0.03298 -0.25112 -0.00000
E29 0.37749 -0.00557 0.00000
E30 0.43046 -0.17366 0.00000
E31 -0.43046 0.17366 -0.00000
E32 -0.37749 0.00557 -0.00000
E33 0.03292 0.25326 -0.00000
E34 0.20947 -0.30703 0.00001
E35 -0.20947 0.30703 -0.00001
E36 -0.03292 -0.25326 0.00000

E61
Concrete Analysis Criteria
RAM Concrete Analysis v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

MEMBER ANALYSIS CRITERIA - GLOBAL


Concrete Design Code:
ACI 318-14
Analysis :
Number of stations per beam: 10
Max spacing between stations (cm): 30.00
Rigid End Zone : Ignore
Torsional Cracked Factor from section property: Yes
Skip-load Live Load on Beam Line beams : Yes
Skip-load Live Load on the Non-beam Line beams : Yes
Consider Live Load Reduction : Yes
Consider Column Slenderness : Yes
Pin Base of Gravity Concrete Columns: Yes
Pin Base of Column on Transfer Member: No
Pin Top of Gravity Columns: No
Remove Diaphragm Constraint on Sloped Floors: No
Load Polygons as Load Cases on Two-way deck: No
Ignore Wall Stiffness on Above Story: No
Include Out-of-Plane Stiffness for One-Way Decks Yes
in Hybrid Slabs:
Merge Node Tolerance(cm): 0.0125
Max. Distance Allowed Between Nodes(cm): 150.0000
Geometric Tolerance(cm): 0.0250
Hard Node Density Factor: 1.0
Solver Type: In-core Sparse

Sidesway: Braced

Column Effective Length :


kx: Code
ky: Code

Column Bracing:
Slab braces column
Max Angle for which Beam Braces Column: 45.00 deg

Source of Column/Wall Forces :


Use RAM Concrete Analysis Forces at all levels.

MEMBER ANALYSIS CRITERIA - ASSIGNED


Level: TO ROOF
Concrete Column:
# Effective Length SideSway

E62
Concrete Analysis Criteria
RAM Concrete Analysis v16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
kx ky Major Minor
1 Global Global Global Global
2 Global Global Global Global
3 Global Global Global Global
4 Global Global Global Global
5 Global Global Global Global
6 Global Global Global Global
7 Global Global Global Global
8 Global Global Global Global

Level: TO STEM WALL


Concrete Column:
# Effective Length SideSway
kx ky Major Minor
1 Global Global Global Global
2 Global Global Global Global
3 Global Global Global Global
4 Global Global Global Global
5 Global Global Global Global
6 Global Global Global Global
7 Global Global Global Global
8 Global Global Global Global

E63
Concrete Model Data
RAM Concrete Analysis v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

STORY DATA:
Level Story Label Layout Type Height (m)
2 TO ROOF TO ROOF 4.000
1 TO STEM WALL TO STEM WALL 1.000

COLUMN SECTION PROPERTIES:


# Label Shape Depth/Diam Width Cracked Factor
mm mm Axial Flex Tors
1 C1 Rect 400.00 400.00 1.00 0.70 1.00

BEAM SECTION PROPERTIES:


# Label Shape Depth Width Flange Thick Cracked Factor
Overhang Thick Axial Flex Tors
mm mm mm mm mm
1 B1 Rect 550.0 500.00 ---- ---- ---- 1.00 0.35 0.10
0
2 B2 Rect 550.0 600.00 ---- ---- ---- 1.00 0.35 0.10
0

MEMBERS:

Level: TO ROOF
Columns
# X Y Z-Offset RigMaj RigMin FrameType Fixity Section
m m m mm mm
1 0.20 0.20 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF
2 0.20 5.60 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF
3 0.20 11.00 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
4 4.35 0.20 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF
5 4.35 11.00 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF
6 8.50 0.20 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
7 8.50 5.60 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF
8 8.50 11.00 0.00 275.00 275.00 Gravity FFF 1
0.00 0.00 FFF

Beams
BeamLine #1 E64
Concrete Model Data
RAM Concrete Analysis v16.00.00.28 Page 2/3
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
1 0.20 5.60 0.00 200.00 Gravity FFF 281.2 2
8.50 5.60 0.00 200.00 FFF

BeamLine #2
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
2 0.25 0.25 0.00 0.00 Gravity FFF 281.2 1
0.25 5.60 0.00 0.00 FFF

BeamLine #3
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
3 0.25 0.25 0.00 0.00 Gravity FFF 281.2 1
4.35 0.25 0.00 0.00 FFF

BeamLine #4
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
6 4.35 10.95 0.00 0.00 Gravity FFF 281.2 1
8.45 10.95 0.00 0.00 FFF

BeamLine #5
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
7 8.45 5.60 0.00 0.00 Gravity FFF 281.2 1
8.45 10.95 0.00 0.00 FFF

BeamLine #6
# X Y Z-Offset RigEnd FrameType Fixity f'c Section
m m m mm kg/cm2
14 4.35 5.60 0.00 0.00 Gravity FFF 281.2 2
4.35 11.00 0.00 200.00 FFF
15 4.35 0.20 0.00 200.00 Gravity FFF 281.2 2
4.35 5.60 0.00 0.00 FFF

Level: TO STEM WALL


Columns
# X Y Z-Offset RigMaj RigMin FrameType Fixity Section
m m m mm mm
1 4.35 11.00 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
2 0.20 11.00 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
3 8.50 11.00 0.00 0.00
E65 0.00 Gravity FFF 1
Concrete Model Data
RAM Concrete Analysis v16.00.00.28 Page 3/3
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
# X Y Z-Offset RigMaj RigMin FrameType Fixity Section
0.00 0.00 FFF
4 8.50 5.60 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
5 0.20 5.60 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
6 0.20 0.20 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
7 4.35 0.20 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF
8 8.50 0.20 0.00 0.00 0.00 Gravity FFF 1
0.00 0.00 FFF

E66
Member Analysis Properties
RAM Concrete Analysis v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

SECTION DIMENSIONS:

Level: TO ROOF
Concrete Beams:
# Label Shape Depth Web-Thick Flange
Overhang Thickness
cm cm cm cm
1 B2 Rect 55.0 60.0 ---- ----
2 B1 Rect 55.0 50.0 ---- ----
3 B1 Rect 55.0 50.0 ---- ----
6 B1 Rect 55.0 50.0 ---- ----
7 B1 Rect 55.0 50.0 ---- ----
14 B2 Rect 55.0 60.0 ---- ----
15 B2 Rect 55.0 60.0 ---- ----

Concrete Columns:
# Label Shape Depth/Diam Width
cm cm
1 C1 Rect 40.0 40.0
2 C1 Rect 40.0 40.0
3 C1 Rect 40.0 40.0
4 C1 Rect 40.0 40.0
5 C1 Rect 40.0 40.0
6 C1 Rect 40.0 40.0
7 C1 Rect 40.0 40.0
8 C1 Rect 40.0 40.0

Level: TO STEM WALL

Concrete Columns:
# Label Shape Depth/Diam Width
cm cm
1 C1 Rect 40.0 40.0
2 C1 Rect 40.0 40.0
3 C1 Rect 40.0 40.0
4 C1 Rect 40.0 40.0
5 C1 Rect 40.0 40.0
6 C1 Rect 40.0 40.0
7 C1 Rect 40.0 40.0
8 C1 Rect 40.0 40.0

CALCULATED SECTION PROPERTIES:


All calculated inertias include crack section factor reduction.
E67
Member Analysis Properties
RAM Concrete Analysis v16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Level: TO ROOF
Beams:
# Label Shape Ix Iy A J Cracked Factor
cm4 cm4 cm2 cm4 Axial Flex Tors
1 B2 Rect 291156.2 346500.0 3300.0 140586.9 1.00 0.35 0.10
2 B1 Rect 242630.2 200520.8 2750.0 97916.7 1.00 0.35 0.10
3 B1 Rect 242630.2 200520.8 2750.0 97916.7 1.00 0.35 0.10
6 B1 Rect 242630.2 200520.8 2750.0 97916.7 1.00 0.35 0.10
7 B1 Rect 242630.2 200520.8 2750.0 97916.7 1.00 0.35 0.10
14 B2 Rect 291156.2 346500.0 3300.0 140586.9 1.00 0.35 0.10
15 B2 Rect 291156.2 346500.0 3300.0 140586.9 1.00 0.35 0.10

Columns:
# Label Shape Ix Iy A J Cracked Factor
cm4 cm4 cm2 cm4 Axial Flex Tors
1 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
2 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
3 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
4 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
5 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
6 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
7 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
8 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00

Level: TO STEM WALL

Columns:
# Label Shape Ix Iy A J Cracked Factor
cm4 cm4 cm2 cm4 Axial Flex Tors
1 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
2 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
3 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
4 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
5 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
6 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
7 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00
8 C1 Rect 149333.3 149333.3 1600.0 315733.3 1.00 0.70 1.00

E68
Design Criteria
RAM Concrete Beam v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

BEAM DESIGN CRITERIA - GLOBAL:


Reinforcement Properties Table: ramgb50010
Code: ACI 318-14
Frame Type:
Special Moment Frame
Load Combination Factors:
ACI 318-99 Sec 21.3.4.1 Dead: 1.20 Live: 1.00 Snow: 0.20
Reinforcement:
Clear Bar Spacing - Shear/Transverse Ties (mm) Max: Code Min: Code
Clear Bar Spacing - Flexure/Longitudinal (mm) Max: Code Min: Code
Longitudinal Reinforcement Ratio Max: Code Min: Code
Clear Bar Cover (mm): Top: Code Bot.: Code Side: Code
Assumed Cover to Center of Bars Top Bottom
(mm):
Gravity Beams 1-Layer: 75.00 2-Layers: 100.00 1-Layer: 75.00 2-Layers: 100.00
Lateral Beams 1-Layer: 75.00 2-Layers: 100.00 1-Layer: 75.00 2-Layers: 100.00
Two Layers of Bars Not Allowed
Bar Sizes Considered - Transverse #12
Bar Sizes Considered - Longitudinal #20
Bar Selection:
Minimum Number of Bars in Beam Top 2
Minimum Number of Bars in Beam Bottom 2
Keep all bars in layer the same size Yes
Adjacent bars may differ in size by 2
Transverse Segment Length Increment (mm) 300.00
Transverse Bar Spacing Increment (mm) 25.00
Selection Method Minimum Bar Area
Bias Bar Size Medium
Amount of Bias Medium
Design Checks:
Include Torsional Capacity Code Check
Do Not Include Deep Beam Code Check
Lateral Beam Gravity Design Forces from RAM Concrete Analysis
Detailing Defaults:
Gravity Gravity Lateral
Beams Joists Beams
Top bars, end support: Extend from end support (xL) 0.25 0.25 0.25
Top bars, end support: Extend from interior support (xL) 0.33 0.33 0.33
Top bars, interior span: Extend from interior support (xL) 0.33 0.33 0.33
Top bars Minimum Number Continuous 0 0 0
Top bars Splice type A A A
Bottom bars, end span: Cutoff from interior support (xL) 0.10 0.10 0.10
Bottom bars, interior span: Cutoff from interiorE69
support (xL) 0.10 0.10 0.10
Design Criteria
RAM Concrete Beam v16.00.00.28 Page 2/4
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Bottom bars Minimum Number Continuous 2 2 2
Bottom Bar End Condition at end support Hooked Hooked Hooked
Stirrup Start Location from face of end support (mm) 50.00 50.00 50.00
Stirrup Start Location from face of interior support (mm) 50.00 50.00 50.00
Stirrup Type Closed Open Closed
Number of Stirrup Legs 2 1 4

E70
Design Criteria
RAM Concrete Beam v16.00.00.28 Page 3/4
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

Deflection Criteria:
Minimum Allowable Span-To-Deflection Ratios Default
Ln/d delta
(mm)
Dead Load: 0.0 0.0
Live Load: 360.0 0.0
Long Term + Live Load: 240.0 0.0
Net Total (Total - Camber): 0.0 0.0

Long Term Deflection


Initial time dependent factor 0.00
Final time dependent factor 2.00
Percent of Live Load Sustained 30.00

Effective Moment of Intertia Per ACI


Camber Criteria:
Do Not Camber

E71
Design Criteria
RAM Concrete Beam v16.00.00.28 Page 4/4
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

BEAM DESIGN CRITERIA - ASSIGNED:

Story Level: TO STEM WALL

No Beam Lines on Story

Story Level: TO ROOF


Num Top Cover Bot Cover Transverse
Bm Bm Design Bar Layer Layer Reinf.
# Line Section Type Layers 1 2 1 2 Legs Type
1 1 B2 Beam Global Global Global Global Global 2 Closed
2 2 B1 Beam Global Global Global Global Global Global Global
3 3 B1 Beam Global Global Global Global Global Global Global
6 4 B1 Beam Global Global Global Global Global Global Global
7 5 B1 Beam Global Global Global Global Global Global Global
15 6 B2 Beam Global Global Global Global Global Global Global
14 6 B2 Beam Global Global Global Global Global Global Global

E72
Load Combinations
RAM Concrete Beam v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

LOAD CASES:
D DeadLoad RAMUSER
Rfp PosRoofLiveLoad RAMUSER
W1 Wind Wind_ASCE710_1_X
W2 Wind Wind_ASCE710_1_Y
W3 Wind Wind_ASCE710_2_X+E
W4 Wind Wind_ASCE710_2_X-E
W5 Wind Wind_ASCE710_2_Y+E
W6 Wind Wind_ASCE710_2_Y-E
W7 Wind Wind_ASCE710_3_X+Y
W8 Wind Wind_ASCE710_3_X-Y
W9 Wind Wind_ASCE710_4_X+Y_CW
W10 Wind Wind_ASCE710_4_X+Y_CCW
W11 Wind Wind_ASCE710_4_X-Y_CW
W12 Wind Wind_ASCE710_4_X-Y_CCW
E1 Seismic EQ_ASCE710_X_+E_F
E2 Seismic EQ_ASCE710_X_-E_F
E3 Seismic EQ_ASCE710_Y_+E_F
E4 Seismic EQ_ASCE710_Y_-E_F
E5 Seismic EQ_ASCE710_X_+E_0.3Y_+E_F
E6 Seismic EQ_ASCE710_X_+E_-0.3Y_+E_F
E7 Seismic EQ_ASCE710_-X_+E_0.3Y_+E_F
E8 Seismic EQ_ASCE710_-X_+E_-0.3Y_+E_F
E9 Seismic EQ_ASCE710_0.3X_+E_Y_+E_F
E10 Seismic EQ_ASCE710_0.3X_+E_-Y_+E_F
E11 Seismic EQ_ASCE710_-0.3X_+E_Y_+E_F
E12 Seismic EQ_ASCE710_-0.3X_+E_-Y_+E_F
E13 Seismic EQ_ASCE710_X_+E_0.3Y_-E_F
E14 Seismic EQ_ASCE710_X_+E_-0.3Y_-E_F
E15 Seismic EQ_ASCE710_-X_+E_0.3Y_-E_F
E16 Seismic EQ_ASCE710_-X_+E_-0.3Y_-E_F
E17 Seismic EQ_ASCE710_0.3X_+E_Y_-E_F
E18 Seismic EQ_ASCE710_0.3X_+E_-Y_-E_F
E19 Seismic EQ_ASCE710_-0.3X_+E_Y_-E_F
E20 Seismic EQ_ASCE710_-0.3X_+E_-Y_-E_F
E21 Seismic EQ_ASCE710_X_-E_0.3Y_+E_F
E22 Seismic EQ_ASCE710_X_-E_-0.3Y_+E_F
E23 Seismic EQ_ASCE710_-X_-E_0.3Y_+E_F
E24 Seismic EQ_ASCE710_-X_-E_-0.3Y_+E_F
E25 Seismic EQ_ASCE710_0.3X_-E_Y_+E_F
E26 Seismic EQ_ASCE710_0.3X_-E_-Y_+E_F
E27 Seismic EQ_ASCE710_-0.3X_-E_Y_+E_F
E28 Seismic EQ_ASCE710_-0.3X_-E_-Y_+E_F
E29 Seismic EQ_ASCE710_X_-E_0.3Y_-E_F
E30 Seismic EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 Seismic E73
EQ_ASCE710_-X_-E_0.3Y_-E_F
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 2/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
E32 Seismic EQ_ASCE710_-X_-E_-0.3Y_-E_F
E33 Seismic EQ_ASCE710_0.3X_-E_Y_-E_F
E34 Seismic EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 Seismic EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 Seismic EQ_ASCE710_-0.3X_-E_-Y_-E_F

COMBINATION CRITERIA:
Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Unreducible
Live Load factor f1 (0.5 or 0.500
1.0)
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300

GENERATED COMBINATIONS:
1 * 1.400 D
2 * 1.200 D + 1.600 Rfp
3 * 1.200 D + 1.600 Rfp + 0.500 W1
4 * 1.200 D + 1.600 Rfp + 0.500 W2
5 * 1.200 D + 1.600 Rfp + 0.500 W3
6 * 1.200 D + 1.600 Rfp + 0.500 W4
7 * 1.200 D + 1.600 Rfp + 0.500 W5
8 * 1.200 D + 1.600 Rfp + 0.500 W6
9 * 1.200 D + 1.600 Rfp + 0.500 W7
10 * 1.200 D + 1.600 Rfp + 0.500 W8
11 * 1.200 D + 1.600 Rfp + 0.500 W9
12 * 1.200 D + 1.600 Rfp + 0.500 W10
13 * 1.200 D + 1.600 Rfp + 0.500 W11
14 * 1.200 D + 1.600 Rfp + 0.500 W12
15 * 1.200 D + 1.600 Rfp - 0.500 W1
16 * 1.200 D + 1.600 Rfp - 0.500 W2
17 * 1.200 D + 1.600 Rfp - 0.500 W3
18 * 1.200 D + 1.600 Rfp - 0.500 W4
19 * 1.200 D + 1.600 Rfp - 0.500 W5
20 * 1.200 D + 1.600 Rfp - 0.500 W6
21 * 1.200 D + 1.600 Rfp - 0.500 W7
22 * 1.200 D + 1.600 Rfp - 0.500 W8
23 * 1.200 D + 1.600 Rfp - 0.500 W9
24 * 1.200 D + 1.600 Rfp - 0.500 W10
25 * 1.200 D + 1.600 Rfp - 0.500 W11
26 * 1.200 D + 1.600 Rfp - 0.500 W12
27 * 1.200 D + 0.500 Rfp + 1.000 W1
28 * 1.200 D + 0.500 Rfp + 1.000 W2
29 * 1.200 D + 0.500 Rfp + 1.000 W3
E74
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 3/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
30 * 1.200 D + 0.500 Rfp + 1.000 W4
31 * 1.200 D + 0.500 Rfp + 1.000 W5
32 * 1.200 D + 0.500 Rfp + 1.000 W6
33 * 1.200 D + 0.500 Rfp + 1.000 W7
34 * 1.200 D + 0.500 Rfp + 1.000 W8
35 * 1.200 D + 0.500 Rfp + 1.000 W9
36 * 1.200 D + 0.500 Rfp + 1.000 W10
37 * 1.200 D + 0.500 Rfp + 1.000 W11
38 * 1.200 D + 0.500 Rfp + 1.000 W12
39 * 1.200 D + 0.500 Rfp - 1.000 W1
40 * 1.200 D + 0.500 Rfp - 1.000 W2
41 * 1.200 D + 0.500 Rfp - 1.000 W3
42 * 1.200 D + 0.500 Rfp - 1.000 W4
43 * 1.200 D + 0.500 Rfp - 1.000 W5
44 * 1.200 D + 0.500 Rfp - 1.000 W6
45 * 1.200 D + 0.500 Rfp - 1.000 W7
46 * 1.200 D + 0.500 Rfp - 1.000 W8
47 * 1.200 D + 0.500 Rfp - 1.000 W9
48 * 1.200 D + 0.500 Rfp - 1.000 W10
49 * 1.200 D + 0.500 Rfp - 1.000 W11
50 * 1.200 D + 0.500 Rfp - 1.000 W12
51 * 1.200 D + 1.000 W1
52 * 1.200 D + 1.000 W2
53 * 1.200 D + 1.000 W3
54 * 1.200 D + 1.000 W4
55 * 1.200 D + 1.000 W5
56 * 1.200 D + 1.000 W6
57 * 1.200 D + 1.000 W7
58 * 1.200 D + 1.000 W8
59 * 1.200 D + 1.000 W9
60 * 1.200 D + 1.000 W10
61 * 1.200 D + 1.000 W11
62 * 1.200 D + 1.000 W12
63 * 1.200 D - 1.000 W1
64 * 1.200 D - 1.000 W2
65 * 1.200 D - 1.000 W3
66 * 1.200 D - 1.000 W4
67 * 1.200 D - 1.000 W5
68 * 1.200 D - 1.000 W6
69 * 1.200 D - 1.000 W7
70 * 1.200 D - 1.000 W8
71 * 1.200 D - 1.000 W9
72 * 1.200 D - 1.000 W10
73 * 1.200 D - 1.000 W11
74 * 1.200 D - 1.000 W12
75 * 0.900 D + 1.000 W1 E75
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 4/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
76 * 0.900 D + 1.000 W2
77 * 0.900 D + 1.000 W3
78 * 0.900 D + 1.000 W4
79 * 0.900 D + 1.000 W5
80 * 0.900 D + 1.000 W6
81 * 0.900 D + 1.000 W7
82 * 0.900 D + 1.000 W8
83 * 0.900 D + 1.000 W9
84 * 0.900 D + 1.000 W10
85 * 0.900 D + 1.000 W11
86 * 0.900 D + 1.000 W12
87 * 0.900 D - 1.000 W1
88 * 0.900 D - 1.000 W2
89 * 0.900 D - 1.000 W3
90 * 0.900 D - 1.000 W4
91 * 0.900 D - 1.000 W5
92 * 0.900 D - 1.000 W6
93 * 0.900 D - 1.000 W7
94 * 0.900 D - 1.000 W8
95 * 0.900 D - 1.000 W9
96 * 0.900 D - 1.000 W10
97 * 0.900 D - 1.000 W11
98 * 0.900 D - 1.000 W12
99 * 1.274 D + 1.300 E1
100 * 1.274 D + 1.300 E2
101 * 1.274 D + 1.300 E3
102 * 1.274 D + 1.300 E4
103 * 1.274 D + 1.300 E5
104 * 1.274 D + 1.300 E6
105 * 1.274 D + 1.300 E7
106 * 1.274 D + 1.300 E8
107 * 1.274 D + 1.300 E9
108 * 1.274 D + 1.300 E10
109 * 1.274 D + 1.300 E11
110 * 1.274 D + 1.300 E12
111 * 1.274 D + 1.300 E13
112 * 1.274 D + 1.300 E14
113 * 1.274 D + 1.300 E15
114 * 1.274 D + 1.300 E16
115 * 1.274 D + 1.300 E17
116 * 1.274 D + 1.300 E18
117 * 1.274 D + 1.300 E19
118 * 1.274 D + 1.300 E20
119 * 1.274 D + 1.300 E21
120 * 1.274 D + 1.300 E22
121 * 1.274 D + 1.300 E23 E76
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 5/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
122 * 1.274 D + 1.300 E24
123 * 1.274 D + 1.300 E25
124 * 1.274 D + 1.300 E26
125 * 1.274 D + 1.300 E27
126 * 1.274 D + 1.300 E28
127 * 1.274 D + 1.300 E29
128 * 1.274 D + 1.300 E30
129 * 1.274 D + 1.300 E31
130 * 1.274 D + 1.300 E32
131 * 1.274 D + 1.300 E33
132 * 1.274 D + 1.300 E34
133 * 1.274 D + 1.300 E35
134 * 1.274 D + 1.300 E36
135 * 1.274 D - 1.300 E1
136 * 1.274 D - 1.300 E2
137 * 1.274 D - 1.300 E3
138 * 1.274 D - 1.300 E4
139 * 1.274 D - 1.300 E5
140 * 1.274 D - 1.300 E6
141 * 1.274 D - 1.300 E7
142 * 1.274 D - 1.300 E8
143 * 1.274 D - 1.300 E9
144 * 1.274 D - 1.300 E10
145 * 1.274 D - 1.300 E11
146 * 1.274 D - 1.300 E12
147 * 1.274 D - 1.300 E13
148 * 1.274 D - 1.300 E14
149 * 1.274 D - 1.300 E15
150 * 1.274 D - 1.300 E16
151 * 1.274 D - 1.300 E17
152 * 1.274 D - 1.300 E18
153 * 1.274 D - 1.300 E19
154 * 1.274 D - 1.300 E20
155 * 1.274 D - 1.300 E21
156 * 1.274 D - 1.300 E22
157 * 1.274 D - 1.300 E23
158 * 1.274 D - 1.300 E24
159 * 1.274 D - 1.300 E25
160 * 1.274 D - 1.300 E26
161 * 1.274 D - 1.300 E27
162 * 1.274 D - 1.300 E28
163 * 1.274 D - 1.300 E29
164 * 1.274 D - 1.300 E30
165 * 1.274 D - 1.300 E31
166 * 1.274 D - 1.300 E32
167 * 1.274 D - 1.300 E33 E77
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 6/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
168 * 1.274 D - 1.300 E34
169 * 1.274 D - 1.300 E35
170 * 1.274 D - 1.300 E36
171 * 0.826 D + 1.300 E1
172 * 0.826 D + 1.300 E2
173 * 0.826 D + 1.300 E3
174 * 0.826 D + 1.300 E4
175 * 0.826 D + 1.300 E5
176 * 0.826 D + 1.300 E6
177 * 0.826 D + 1.300 E7
178 * 0.826 D + 1.300 E8
179 * 0.826 D + 1.300 E9
180 * 0.826 D + 1.300 E10
181 * 0.826 D + 1.300 E11
182 * 0.826 D + 1.300 E12
183 * 0.826 D + 1.300 E13
184 * 0.826 D + 1.300 E14
185 * 0.826 D + 1.300 E15
186 * 0.826 D + 1.300 E16
187 * 0.826 D + 1.300 E17
188 * 0.826 D + 1.300 E18
189 * 0.826 D + 1.300 E19
190 * 0.826 D + 1.300 E20
191 * 0.826 D + 1.300 E21
192 * 0.826 D + 1.300 E22
193 * 0.826 D + 1.300 E23
194 * 0.826 D + 1.300 E24
195 * 0.826 D + 1.300 E25
196 * 0.826 D + 1.300 E26
197 * 0.826 D + 1.300 E27
198 * 0.826 D + 1.300 E28
199 * 0.826 D + 1.300 E29
200 * 0.826 D + 1.300 E30
201 * 0.826 D + 1.300 E31
202 * 0.826 D + 1.300 E32
203 * 0.826 D + 1.300 E33
204 * 0.826 D + 1.300 E34
205 * 0.826 D + 1.300 E35
206 * 0.826 D + 1.300 E36
207 * 0.826 D - 1.300 E1
208 * 0.826 D - 1.300 E2
209 * 0.826 D - 1.300 E3
210 * 0.826 D - 1.300 E4
211 * 0.826 D - 1.300 E5
212 * 0.826 D - 1.300 E6
213 * 0.826 D - 1.300 E7 E78
Load Combinations
RAM Concrete Beam v16.00.00.28 Page 7/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
214 * 0.826 D - 1.300 E8
215 * 0.826 D - 1.300 E9
216 * 0.826 D - 1.300 E10
217 * 0.826 D - 1.300 E11
218 * 0.826 D - 1.300 E12
219 * 0.826 D - 1.300 E13
220 * 0.826 D - 1.300 E14
221 * 0.826 D - 1.300 E15
222 * 0.826 D - 1.300 E16
223 * 0.826 D - 1.300 E17
224 * 0.826 D - 1.300 E18
225 * 0.826 D - 1.300 E19
226 * 0.826 D - 1.300 E20
227 * 0.826 D - 1.300 E21
228 * 0.826 D - 1.300 E22
229 * 0.826 D - 1.300 E23
230 * 0.826 D - 1.300 E24
231 * 0.826 D - 1.300 E25
232 * 0.826 D - 1.300 E26
233 * 0.826 D - 1.300 E27
234 * 0.826 D - 1.300 E28
235 * 0.826 D - 1.300 E29
236 * 0.826 D - 1.300 E30
237 * 0.826 D - 1.300 E31
238 * 0.826 D - 1.300 E32
239 * 0.826 D - 1.300 E33
240 * 0.826 D - 1.300 E34
241 * 0.826 D - 1.300 E35
242 * 0.826 D - 1.300 E36

E79
Beam Design Summary
RAM Concrete Beam v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

Story Level: TO ROOF Beam Line: 1


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (0.20m-5.60m) 0.00 Column 400.00 400.00 NA
2 (8.50m-5.60m) 8.30 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 8.30 B2 550.00 600.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 4 475.000 Upper 1 0.000 1 4.200 Hooked Splice
2 #20 4 475.000 Upper 2 -4.100 2 -0.000 Splice Hooked

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 4 475.000 Lower 1 0.000 1 8.300 Hooked Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 100.00 79 1 0.250 1 8.050 2 Closed

Story Level: TO ROOF Beam Line: 2


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (1'-A') 0.00 Column 400.00 400.00 NA
2 (0.20m-5.60m) 5.35 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum

E80
Beam Design Summary
RAM Concrete Beam v16.00.00.28 Page 2/5
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 5.35 B1 550.00 500.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Upper 1 0.000 1 2.700 Hooked Splice
2 #20 3 475.000 Upper 2 -2.650 2 -0.000 Splice Hooked

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Lower 1 0.000 1 5.350 Hooked Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 225.00 10 1 0.250 1 2.350 2 Closed
2 #12 200.00 15 1 2.350 1 5.100 2 Closed

Story Level: TO ROOF Beam Line: 3


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (1'-A') 0.00 Column 400.00 400.00 NA
2 (4.35m-0.20m) 4.10 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 4.10 B1 550.00 500.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Upper 1 0.000 1 2.100 Hooked Splice
2 #20 3 475.000 Upper 2 -2.000 2 -0.000 Splice Hooked
E81
Beam Design Summary
RAM Concrete Beam v16.00.00.28 Page 3/5
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Lower 1 0.000 1 4.100 Hooked Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 200.00 8 1 0.250 1 1.750 2 Closed
2 #12 175.00 13 1 1.750 1 3.850 2 Closed

Story Level: TO ROOF Beam Line: 4


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (4.35m-11.00m) 0.00 Column 400.00 400.00 NA
2 (3'-C') 4.10 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 4.10 B1 550.00 500.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Upper 1 0.000 1 2.100 Hooked Splice
2 #20 3 475.000 Upper 2 -2.000 2 -0.000 Splice Hooked

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Lower 1 0.000 1 4.100 Hooked Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup

E82
Beam Design Summary
RAM Concrete Beam v16.00.00.28 Page 4/5
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 175.00 10 1 0.250 1 1.750 2 Closed
2 #12 200.00 11 1 1.750 1 3.850 2 Closed

Story Level: TO ROOF Beam Line: 5


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (8.50m-5.60m) 0.00 Column 400.00 400.00 NA
2 (3'-C') 5.35 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 5.35 B1 550.00 500.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Upper 1 0.000 1 2.700 Hooked Splice
2 #20 3 475.000 Upper 2 -2.650 2 -0.000 Splice Hooked

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 3 475.000 Lower 1 0.000 1 5.350 Hooked Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 200.00 12 1 0.250 1 2.350 2 Closed
2 #12 225.00 13 1 2.350 1 5.100 2 Closed

Story Level: TO ROOF Beam Line: 6


SUPPORT GEOMETRY:
Index Grid Loc. Loc. Type Length Width Depth
(m) (mm) (mm) (mm)
1 (4.35m-0.20m) 0.00 E83
Column 400.00 400.00 NA
Beam Design Summary
RAM Concrete Beam v16.00.00.28 Page 5/5
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Index Grid Loc. Loc. Type Length Width Depth
2 (0.20m-5.60m) 5.40 Beam 600.00 NA 600.00
3 (4.35m-11.00m) 10.80 Column 400.00 400.00 NA

BEAM GEOMETRY:
Web Flange Minimum
Index Span Section Depth Width Width SlabThick.
(m) (mm) (mm) (mm) (mm)
1 5.40 B2 550.00 600.00 NA NA
2 5.40 B2 550.00 600.00 NA NA

TOP LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 4 475.000 Upper 1 0.000 1 2.700 Hooked Splice
2 #20 4 475.000 Upper 2 -2.700 2 2.700 Splice Splice
3 #20 4 475.000 Upper 3 -2.700 3 -0.000 Splice Hooked

BOTTOM LONGITUDINAL REINFORCEMENT:


Start End End-Condition
Set Size Num Depth Layer Supp. Loc. Supp. Loc. Start End
(mm) (m) (m)
1 #20 4 475.000 Lower 1 0.000 1 5.400 Hooked Splice
2 #20 4 475.000 Lower 2 -0.000 2 5.400 Splice Hooked

TRANSVERSE REINFORCEMENT:
Start End Stirrup
Set Size Spacing Num Supp. Loc. Supp. Loc. Legs Type
(m) (m)
1 #12 175.00 13 1 0.250 1 2.350 2 Closed
2 #12 225.00 12 1 2.350 1 5.050 2 Closed
3 #12 225.00 10 2 0.350 2 2.450 2 Closed
4 #12 175.00 17 2 2.450 2 5.150 2 Closed

E84
Beam Deflection Summary
RAM Concrete Beam v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

Story Level: TO ROOF Beam Line: 1


Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 1 B2 0.000 2.55 0.23 4.53 7.08 0.14
Story Level: TO ROOF Beam Line: 2
Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 2 B1 0.000 0.68 0.04 1.21 1.89 0.06
Story Level: TO ROOF Beam Line: 3
Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 3 B1 0.000 0.31 0.02 0.55 0.86 0.04
Story Level: TO ROOF Beam Line: 4
Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 6 B1 0.000 0.31 0.02 0.55 0.86 0.04
Story Level: TO ROOF Beam Line: 5
Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 7 B1 0.000 0.69 0.04 1.21 1.90 0.06
Story Level: TO ROOF Beam Line: 6
Index Bm# Size Camber DL LL LT+LL Net Ratio
(mm) (mm) (mm) (mm) (mm)
1 15 B2 0.000 0.56 0.05 1.00 1.56 0.05
2 14 B2 0.000 0.57 0.05 1.01 1.58 0.05

E85
Concrete Column Design Criteria
RAM Concrete Column v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

COLUMN DESIGN CRITERIA - GLOBAL:


Reinforcement Properties Table: ramgb50010
Code: ACI 318-14
Frame Type:
Special Moment Frame
Load Combination Factors:
ACI 318-99 Sec 21.3.4.1 Dead: 1.20 Live: 1.00 Snow: 0.20
Seismic Design Category: D
Reinforcement:
Clear Bar Spacing - Shear/Transverse Ties (mm) Max: CODE Min: CODE
Clear Bar Spacing - Shear Spiral (mm) Max: CODE Min: CODE
Clear Bar Spacing - Flexure + Axial/Longitudinal (mm) Max: CODE Min: CODE
Reinforcement Ratio Max: CODE Min: CODE
Clear Bar Cover (mm) CODE
Bar Selection:
Transverse Segment Spacing Increment (mm) 100.00
Transverse Bar Spacing Increment (mm) 25.00
Number Of Shear Bar Legs Major: 2 Minor: 2
Design Checks:
Include Torsional Capacity Code Check
Include Max Column Axial Load Limit Code Check
Lateral Column Gravity Design Forces from RAM Concrete Analysis
Lap Splices:
For Bars less than or equal to #6 use Lap Splice 36.00 x d
For Bars greater than #6 use Lap Splice 55.00 x d
Rectangular Bar Patterns:
Bar Pattern Trans Bar Longitudinal Bars Bar Quantity
Name Size Min Size Max Size Top/Bottom Additional
Side Bars
8 (3 x 1) #16 - #16 #12 #16 #16 3 1

E86
Concrete Column Design Criteria
RAM Concrete Column v16.00.00.28 Page 2/3
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

COLUMN DESIGN CRITERIA - ASSIGNED:

Column Stack Location: (1'-A')


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (0.20m-5.60m)


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (1'-C')


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (4.35m-0.20m)


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (4.35m-11.00m)


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

E87
Concrete Column Design Criteria
RAM Concrete Column v16.00.00.28 Page 3/3
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (3'-A')


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (8.50m-5.60m)


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

Column Stack Location: (3'-C')


Shear Legs
Level Section Major Minor
TO ROOF C1 2 2
TO STEM C1 2 2
WALL

Assigned Pattern Groups 1: 8 (3 x 1) #16 - #16, #12

E88
Load Combinations
RAM Concrete Column v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14

LOAD CASES:
D DeadLoad RAMUSER
Rfp PosRoofLiveLoad RAMUSER
W1 Wind Wind_ASCE710_1_X
W2 Wind Wind_ASCE710_1_Y
W3 Wind Wind_ASCE710_2_X+E
W4 Wind Wind_ASCE710_2_X-E
W5 Wind Wind_ASCE710_2_Y+E
W6 Wind Wind_ASCE710_2_Y-E
W7 Wind Wind_ASCE710_3_X+Y
W8 Wind Wind_ASCE710_3_X-Y
W9 Wind Wind_ASCE710_4_X+Y_CW
W10 Wind Wind_ASCE710_4_X+Y_CCW
W11 Wind Wind_ASCE710_4_X-Y_CW
W12 Wind Wind_ASCE710_4_X-Y_CCW
E1 Seismic EQ_ASCE710_X_+E_F
E2 Seismic EQ_ASCE710_X_-E_F
E3 Seismic EQ_ASCE710_Y_+E_F
E4 Seismic EQ_ASCE710_Y_-E_F
E5 Seismic EQ_ASCE710_X_+E_0.3Y_+E_F
E6 Seismic EQ_ASCE710_X_+E_-0.3Y_+E_F
E7 Seismic EQ_ASCE710_-X_+E_0.3Y_+E_F
E8 Seismic EQ_ASCE710_-X_+E_-0.3Y_+E_F
E9 Seismic EQ_ASCE710_0.3X_+E_Y_+E_F
E10 Seismic EQ_ASCE710_0.3X_+E_-Y_+E_F
E11 Seismic EQ_ASCE710_-0.3X_+E_Y_+E_F
E12 Seismic EQ_ASCE710_-0.3X_+E_-Y_+E_F
E13 Seismic EQ_ASCE710_X_+E_0.3Y_-E_F
E14 Seismic EQ_ASCE710_X_+E_-0.3Y_-E_F
E15 Seismic EQ_ASCE710_-X_+E_0.3Y_-E_F
E16 Seismic EQ_ASCE710_-X_+E_-0.3Y_-E_F
E17 Seismic EQ_ASCE710_0.3X_+E_Y_-E_F
E18 Seismic EQ_ASCE710_0.3X_+E_-Y_-E_F
E19 Seismic EQ_ASCE710_-0.3X_+E_Y_-E_F
E20 Seismic EQ_ASCE710_-0.3X_+E_-Y_-E_F
E21 Seismic EQ_ASCE710_X_-E_0.3Y_+E_F
E22 Seismic EQ_ASCE710_X_-E_-0.3Y_+E_F
E23 Seismic EQ_ASCE710_-X_-E_0.3Y_+E_F
E24 Seismic EQ_ASCE710_-X_-E_-0.3Y_+E_F
E25 Seismic EQ_ASCE710_0.3X_-E_Y_+E_F
E26 Seismic EQ_ASCE710_0.3X_-E_-Y_+E_F
E27 Seismic EQ_ASCE710_-0.3X_-E_Y_+E_F
E28 Seismic EQ_ASCE710_-0.3X_-E_-Y_+E_F
E29 Seismic EQ_ASCE710_X_-E_0.3Y_-E_F
E30 Seismic EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 Seismic E89
EQ_ASCE710_-X_-E_0.3Y_-E_F
Load Combinations
RAM Concrete Column v16.00.00.28 Page 2/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
E32 Seismic EQ_ASCE710_-X_-E_-0.3Y_-E_F
E33 Seismic EQ_ASCE710_0.3X_-E_Y_-E_F
E34 Seismic EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 Seismic EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 Seismic EQ_ASCE710_-0.3X_-E_-Y_-E_F

COMBINATION CRITERIA:
Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Unreducible
Live Load factor f1 (0.5 or 0.500
1.0)
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300

GENERATED COMBINATIONS:
1 * 1.400 D
2 * 1.200 D + 1.600 Rfp
3 * 1.200 D + 1.600 Rfp + 0.500 W1
4 * 1.200 D + 1.600 Rfp + 0.500 W2
5 * 1.200 D + 1.600 Rfp + 0.500 W3
6 * 1.200 D + 1.600 Rfp + 0.500 W4
7 * 1.200 D + 1.600 Rfp + 0.500 W5
8 * 1.200 D + 1.600 Rfp + 0.500 W6
9 * 1.200 D + 1.600 Rfp + 0.500 W7
10 * 1.200 D + 1.600 Rfp + 0.500 W8
11 * 1.200 D + 1.600 Rfp + 0.500 W9
12 * 1.200 D + 1.600 Rfp + 0.500 W10
13 * 1.200 D + 1.600 Rfp + 0.500 W11
14 * 1.200 D + 1.600 Rfp + 0.500 W12
15 * 1.200 D + 1.600 Rfp - 0.500 W1
16 * 1.200 D + 1.600 Rfp - 0.500 W2
17 * 1.200 D + 1.600 Rfp - 0.500 W3
18 * 1.200 D + 1.600 Rfp - 0.500 W4
19 * 1.200 D + 1.600 Rfp - 0.500 W5
20 * 1.200 D + 1.600 Rfp - 0.500 W6
21 * 1.200 D + 1.600 Rfp - 0.500 W7
22 * 1.200 D + 1.600 Rfp - 0.500 W8
23 * 1.200 D + 1.600 Rfp - 0.500 W9
24 * 1.200 D + 1.600 Rfp - 0.500 W10
25 * 1.200 D + 1.600 Rfp - 0.500 W11
26 * 1.200 D + 1.600 Rfp - 0.500 W12
27 * 1.200 D + 0.500 Rfp + 1.000 W1
28 * 1.200 D + 0.500 Rfp + 1.000 W2
29 * 1.200 D + 0.500 Rfp + 1.000 W3
E90
Load Combinations
RAM Concrete Column v16.00.00.28 Page 3/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
30 * 1.200 D + 0.500 Rfp + 1.000 W4
31 * 1.200 D + 0.500 Rfp + 1.000 W5
32 * 1.200 D + 0.500 Rfp + 1.000 W6
33 * 1.200 D + 0.500 Rfp + 1.000 W7
34 * 1.200 D + 0.500 Rfp + 1.000 W8
35 * 1.200 D + 0.500 Rfp + 1.000 W9
36 * 1.200 D + 0.500 Rfp + 1.000 W10
37 * 1.200 D + 0.500 Rfp + 1.000 W11
38 * 1.200 D + 0.500 Rfp + 1.000 W12
39 * 1.200 D + 0.500 Rfp - 1.000 W1
40 * 1.200 D + 0.500 Rfp - 1.000 W2
41 * 1.200 D + 0.500 Rfp - 1.000 W3
42 * 1.200 D + 0.500 Rfp - 1.000 W4
43 * 1.200 D + 0.500 Rfp - 1.000 W5
44 * 1.200 D + 0.500 Rfp - 1.000 W6
45 * 1.200 D + 0.500 Rfp - 1.000 W7
46 * 1.200 D + 0.500 Rfp - 1.000 W8
47 * 1.200 D + 0.500 Rfp - 1.000 W9
48 * 1.200 D + 0.500 Rfp - 1.000 W10
49 * 1.200 D + 0.500 Rfp - 1.000 W11
50 * 1.200 D + 0.500 Rfp - 1.000 W12
51 * 1.200 D + 1.000 W1
52 * 1.200 D + 1.000 W2
53 * 1.200 D + 1.000 W3
54 * 1.200 D + 1.000 W4
55 * 1.200 D + 1.000 W5
56 * 1.200 D + 1.000 W6
57 * 1.200 D + 1.000 W7
58 * 1.200 D + 1.000 W8
59 * 1.200 D + 1.000 W9
60 * 1.200 D + 1.000 W10
61 * 1.200 D + 1.000 W11
62 * 1.200 D + 1.000 W12
63 * 1.200 D - 1.000 W1
64 * 1.200 D - 1.000 W2
65 * 1.200 D - 1.000 W3
66 * 1.200 D - 1.000 W4
67 * 1.200 D - 1.000 W5
68 * 1.200 D - 1.000 W6
69 * 1.200 D - 1.000 W7
70 * 1.200 D - 1.000 W8
71 * 1.200 D - 1.000 W9
72 * 1.200 D - 1.000 W10
73 * 1.200 D - 1.000 W11
74 * 1.200 D - 1.000 W12
75 * 0.900 D + 1.000 W1 E91
Load Combinations
RAM Concrete Column v16.00.00.28 Page 4/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
76 * 0.900 D + 1.000 W2
77 * 0.900 D + 1.000 W3
78 * 0.900 D + 1.000 W4
79 * 0.900 D + 1.000 W5
80 * 0.900 D + 1.000 W6
81 * 0.900 D + 1.000 W7
82 * 0.900 D + 1.000 W8
83 * 0.900 D + 1.000 W9
84 * 0.900 D + 1.000 W10
85 * 0.900 D + 1.000 W11
86 * 0.900 D + 1.000 W12
87 * 0.900 D - 1.000 W1
88 * 0.900 D - 1.000 W2
89 * 0.900 D - 1.000 W3
90 * 0.900 D - 1.000 W4
91 * 0.900 D - 1.000 W5
92 * 0.900 D - 1.000 W6
93 * 0.900 D - 1.000 W7
94 * 0.900 D - 1.000 W8
95 * 0.900 D - 1.000 W9
96 * 0.900 D - 1.000 W10
97 * 0.900 D - 1.000 W11
98 * 0.900 D - 1.000 W12
99 * 1.274 D + 1.300 E1
100 * 1.274 D + 1.300 E2
101 * 1.274 D + 1.300 E3
102 * 1.274 D + 1.300 E4
103 * 1.274 D + 1.300 E5
104 * 1.274 D + 1.300 E6
105 * 1.274 D + 1.300 E7
106 * 1.274 D + 1.300 E8
107 * 1.274 D + 1.300 E9
108 * 1.274 D + 1.300 E10
109 * 1.274 D + 1.300 E11
110 * 1.274 D + 1.300 E12
111 * 1.274 D + 1.300 E13
112 * 1.274 D + 1.300 E14
113 * 1.274 D + 1.300 E15
114 * 1.274 D + 1.300 E16
115 * 1.274 D + 1.300 E17
116 * 1.274 D + 1.300 E18
117 * 1.274 D + 1.300 E19
118 * 1.274 D + 1.300 E20
119 * 1.274 D + 1.300 E21
120 * 1.274 D + 1.300 E22
121 * 1.274 D + 1.300 E23 E92
Load Combinations
RAM Concrete Column v16.00.00.28 Page 5/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
122 * 1.274 D + 1.300 E24
123 * 1.274 D + 1.300 E25
124 * 1.274 D + 1.300 E26
125 * 1.274 D + 1.300 E27
126 * 1.274 D + 1.300 E28
127 * 1.274 D + 1.300 E29
128 * 1.274 D + 1.300 E30
129 * 1.274 D + 1.300 E31
130 * 1.274 D + 1.300 E32
131 * 1.274 D + 1.300 E33
132 * 1.274 D + 1.300 E34
133 * 1.274 D + 1.300 E35
134 * 1.274 D + 1.300 E36
135 * 1.274 D - 1.300 E1
136 * 1.274 D - 1.300 E2
137 * 1.274 D - 1.300 E3
138 * 1.274 D - 1.300 E4
139 * 1.274 D - 1.300 E5
140 * 1.274 D - 1.300 E6
141 * 1.274 D - 1.300 E7
142 * 1.274 D - 1.300 E8
143 * 1.274 D - 1.300 E9
144 * 1.274 D - 1.300 E10
145 * 1.274 D - 1.300 E11
146 * 1.274 D - 1.300 E12
147 * 1.274 D - 1.300 E13
148 * 1.274 D - 1.300 E14
149 * 1.274 D - 1.300 E15
150 * 1.274 D - 1.300 E16
151 * 1.274 D - 1.300 E17
152 * 1.274 D - 1.300 E18
153 * 1.274 D - 1.300 E19
154 * 1.274 D - 1.300 E20
155 * 1.274 D - 1.300 E21
156 * 1.274 D - 1.300 E22
157 * 1.274 D - 1.300 E23
158 * 1.274 D - 1.300 E24
159 * 1.274 D - 1.300 E25
160 * 1.274 D - 1.300 E26
161 * 1.274 D - 1.300 E27
162 * 1.274 D - 1.300 E28
163 * 1.274 D - 1.300 E29
164 * 1.274 D - 1.300 E30
165 * 1.274 D - 1.300 E31
166 * 1.274 D - 1.300 E32
167 * 1.274 D - 1.300 E33 E93
Load Combinations
RAM Concrete Column v16.00.00.28 Page 6/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
168 * 1.274 D - 1.300 E34
169 * 1.274 D - 1.300 E35
170 * 1.274 D - 1.300 E36
171 * 0.826 D + 1.300 E1
172 * 0.826 D + 1.300 E2
173 * 0.826 D + 1.300 E3
174 * 0.826 D + 1.300 E4
175 * 0.826 D + 1.300 E5
176 * 0.826 D + 1.300 E6
177 * 0.826 D + 1.300 E7
178 * 0.826 D + 1.300 E8
179 * 0.826 D + 1.300 E9
180 * 0.826 D + 1.300 E10
181 * 0.826 D + 1.300 E11
182 * 0.826 D + 1.300 E12
183 * 0.826 D + 1.300 E13
184 * 0.826 D + 1.300 E14
185 * 0.826 D + 1.300 E15
186 * 0.826 D + 1.300 E16
187 * 0.826 D + 1.300 E17
188 * 0.826 D + 1.300 E18
189 * 0.826 D + 1.300 E19
190 * 0.826 D + 1.300 E20
191 * 0.826 D + 1.300 E21
192 * 0.826 D + 1.300 E22
193 * 0.826 D + 1.300 E23
194 * 0.826 D + 1.300 E24
195 * 0.826 D + 1.300 E25
196 * 0.826 D + 1.300 E26
197 * 0.826 D + 1.300 E27
198 * 0.826 D + 1.300 E28
199 * 0.826 D + 1.300 E29
200 * 0.826 D + 1.300 E30
201 * 0.826 D + 1.300 E31
202 * 0.826 D + 1.300 E32
203 * 0.826 D + 1.300 E33
204 * 0.826 D + 1.300 E34
205 * 0.826 D + 1.300 E35
206 * 0.826 D + 1.300 E36
207 * 0.826 D - 1.300 E1
208 * 0.826 D - 1.300 E2
209 * 0.826 D - 1.300 E3
210 * 0.826 D - 1.300 E4
211 * 0.826 D - 1.300 E5
212 * 0.826 D - 1.300 E6
213 * 0.826 D - 1.300 E7 E94
Load Combinations
RAM Concrete Column v16.00.00.28 Page 7/7
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 13:39:47
Building Code: IBC Concrete Code: ACI 318-14
214 * 0.826 D - 1.300 E8
215 * 0.826 D - 1.300 E9
216 * 0.826 D - 1.300 E10
217 * 0.826 D - 1.300 E11
218 * 0.826 D - 1.300 E12
219 * 0.826 D - 1.300 E13
220 * 0.826 D - 1.300 E14
221 * 0.826 D - 1.300 E15
222 * 0.826 D - 1.300 E16
223 * 0.826 D - 1.300 E17
224 * 0.826 D - 1.300 E18
225 * 0.826 D - 1.300 E19
226 * 0.826 D - 1.300 E20
227 * 0.826 D - 1.300 E21
228 * 0.826 D - 1.300 E22
229 * 0.826 D - 1.300 E23
230 * 0.826 D - 1.300 E24
231 * 0.826 D - 1.300 E25
232 * 0.826 D - 1.300 E26
233 * 0.826 D - 1.300 E27
234 * 0.826 D - 1.300 E28
235 * 0.826 D - 1.300 E29
236 * 0.826 D - 1.300 E30
237 * 0.826 D - 1.300 E31
238 * 0.826 D - 1.300 E32
239 * 0.826 D - 1.300 E33
240 * 0.826 D - 1.300 E34
241 * 0.826 D - 1.300 E35
242 * 0.826 D - 1.300 E36

E95
Concrete Column Design Summary
RAM Concrete Column v16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 15:24:40
Building Code: IBC Concrete Code: ACI 318-14

Location: 1' - A'


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
1 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.49 #12@96.00 0.00-4000.00 0.25
6 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.06 #12@85.00 0.00-1000.00 0.72

Location: 0.20 m - 5.60 m


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
2 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.65 #12@96.00 0.00-4000.00 0.21
5 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.67 #12@85.00 0.00-1000.00 0.75

Location: 1' - C'


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
3 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.05 #12@96.00 0.00-4000.00 0.19

E96
2 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.04 #12@85.00 0.00-1000.00 0.70

Location: 4.35 m - 0.20 m


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
4 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.57 #12@96.00 0.00-4000.00 0.26
7 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.59 #12@85.00 0.00-1000.00 0.74

Location: 4.35 m - 11.00 m


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
5 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.57 #12@96.00 0.00-4000.00 0.26
1 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.59 #12@85.00 0.00-1000.00 0.74

Location: 3' - A'


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
6 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.04 #12@96.00 0.00-4000.00 0.19
8 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.04 #12@85.00 0.00-1000.00 0.69

Location: 8.50 m - 5.60 m


Concrete Column Design Summary
RAM Concrete Column v16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 04/25/19 15:24:40
Building Code: IBC Concrete Code: ACI 318-14
No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
7 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.65 #12@96.00 0.00-4000.00 0.21
4 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.67 #12@85.00 0.00-1000.00 0.75

Location: 3' - C'


No. Level Section f'c Longitudinal Rho % Ld/Cap Transverse Ld/Cap
8 TO ROOF C1 281.23 8-#16 (3 x 1) 1.01 0.49 #12@96.00 0.00-4000.00 0.25
3 TO STEM WALL C1 281.22 8-#16 (3 x 1) 1.01 0.06 #12@85.00 0.00-1000.00 0.72

E97
Wall Panel Reinforcing
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Wall Design Group: 1


Bar Pattern Template: Wall Reinf

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
TO ROOF 24 (2) #12@450 mm oc 0.25% (2) #12@450 mm oc 0.25%
25 (2) #12@450 mm oc 0.25% (2) #12@450 mm oc 0.25%
26 (2) #12@450 mm oc 0.25% (2) #12@450 mm oc 0.25%
27 (2) #12@450 mm oc 0.25% (2) #12@450 mm oc 0.25%

Wall Design Group: 2


Bar Pattern Template: Stem Wall Reinf

Bar Patterns
Story Wall Panel Vertical rho Horizontal rho
TO STEM 20 (2) #16@300 mm oc 0.34% (2) #16@300 mm oc 0.34%
WALL
21 (2) #16@300 mm oc 0.34% (2) #16@300 mm oc 0.34%
22 (2) #16@300 mm oc 0.34% (2) #16@300 mm oc 0.34%
23 (2) #16@300 mm oc 0.34% (2) #16@300 mm oc 0.34%

E98
Wall Panel Properties
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Wall Design Group: 1

Story: TO ROOF (5.00 m)


Panel Num Thick (cm) Length (m) f'c fy Height (m) Coords (m)
(kg/cm2) (kg/cm2)
Start End
24 20.00 5.400 281.23 4218.5 4.000 4.000 (0.200, 5.600)
(0.200, 11.000)
25 20.00 5.400 281.23 4218.5 4.000 4.000 (8.500, 0.200)
(8.500, 5.600)
26 20.00 4.150 281.23 4218.5 4.000 4.000 (0.200, 11.000)
(4.350, 11.000)
27 20.00 4.150 281.23 4218.5 4.000 4.000 (4.350, 0.200)
(8.500, 0.200)

Wall Design Group: 2

Story: TO STEM WALL (1.00 m)


Panel Num Thick (cm) Length (m) f'c fy Height (m) Coords (m)
(kg/cm2) (kg/cm2)
Start End
20 40.00 4.150 281.23 4218.5 1.000 1.000 (0.200, 11.000)
(4.350, 11.000)
21 40.00 5.400 281.23 4218.5 1.000 1.000 (0.200, 5.600)
(0.200, 11.000)
22 40.00 4.150 281.23 4218.5 1.000 1.000 (4.350, 0.200)
(8.500, 0.200)
23 40.00 5.400 281.23 4218.5 1.000 1.000 (8.500, 0.200)
(8.500, 5.600)

E99
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Section Cut ID: SC1V:153 (Vertical)


Story: TO ROOF
Ag = 8000 cm2 Imaj = 266667 cm4 Imin = 106666685 cm4
Wall Design Group: 1
Design Status: PASS

SC1V:153

Min

Maj
ELEVATION VIEW

Axial/Flexural Results:
Interaction: 0.021 OK
Pu = 13172.38 kgf phiPn = 623948.00 kgf
Mu = 14779.0 kg.m at Beta = 0.0 deg CCW from Major axis
Controlling Load Combo: 1.400 D (LC 1)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1V:153:
Length = 4.00 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #12@450 mm oc Horiz Bar Pat: #12@450 mm oc
Vu = 11248.9 kgf phiVn = 93577.0 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E10 (LC 108)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Horiz Reinf Ratio: Limit: 0.250% Actual: 0.283% (11.6.2) OK
Segment SC1V:153:
Max Horiz Bar Spacing Limit: 457 mm Actual: 450 mm (11.7.3.1) OK
Min Horiz Bar Spacing Limit: 25 mm Actual: 438 mm (25.2.1) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
E100
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

E101
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Section Cut ID: SC1H:174 (Horizontal)


Story: TO ROOF
Ag = 19100 cm2 Imaj = 605155799 cm4 Imin = 321733913 cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 1
Design Status: PASS

SC1H:174A

SC1H:174B

Min

Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.060 OK
Pu = 40242.98 kgf phiPn = 672029.50 kgf
Mu = 57390.5 kg.m at Beta = -55.8 deg CCW from Major axis
Controlling Load Combo: 0.826 D + 1.300 E16 (LC 186)
Code Ref: 11.4.2.1

Shear Results:
Segment SC1H:174A:
Length = 5.40 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #12@450 mm oc Horiz Bar Pat: #12@450 mm oc
Vu = 25043.3 kgf phiVn = 126329.0 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E17 (LC 115)
Code Ref: 11.5.4.5

Segment SC1H:174B:
Length = 4.15 m Thick = 200 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #12@450 mm oc Horiz Bar Pat: #12@450 mm oc
Vu = 23657.0 kgf phiVn = 97086.1 kgf OK
E102
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.274 D + 1.300 E16 (LC 114)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.296% (11.6.2) OK
Segment SC1H:174A:
Max Vert Bar Spacing Limit: 457 mm Actual: 450 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 438 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.251% Actual: 0.251% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC1H:174B:
Max Vert Bar Spacing Limit: 457 mm Actual: 450 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 438 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.251% Actual: 0.251% (18.10.4.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

E103
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Section Cut ID: SC2V:31 (Vertical)


Story: TO STEM WALL
Ag = 4000 cm2 Imaj = 533333 cm4 Imin = 3333333 cm4
Wall Design Group: 2
Design Status: PASS

SC2V:31

Min

Maj
ELEVATION VIEW

Axial/Flexural Results:
Interaction: 0.086 OK
Pu = 195.04 kgf phiPn = 2280.08 kgf
Mu = 2981.1 kg.m at Beta = -0.0 deg CCW from Major axis
Controlling Load Combo: 1.274 D + 1.300 E30 (LC 128)
Code Ref: 11.4.2.1

Shear Results:
Segment SC2V:31:
Length = 1.00 m Thick = 400 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 5715.9 kgf phiVn = 55269.8 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E30 (LC 128)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Horiz Reinf Ratio: Limit: 0.250% Actual: 0.503% (11.6.2) OK
Segment SC2V:31:
Max Horiz Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.3.1) OK
Min Horiz Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Number of Reinf Curtains: 2 Actual: 2 (11.7.2.3) OK
E104
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14

Section Cut ID: SC2H:47 (Horizontal)


Story: TO STEM WALL
Ag = 38200 cm2 Imaj = 1213802068 cm4 Imin = 646708298 cm4
Major Axis Orientation: 90.00 degrees (CCW from global X-axis)
Wall Design Group: 2
Design Status: PASS

SC2H:47B

SC2H:47A

Min

Maj
PLAN VIEW

Axial/Flexural Results:
Interaction: 0.040 OK
Pu = 57810.46 kgf phiPn = 1436941.75 kgf
Mu = 72063.3 kg.m at Beta = -89.5 deg CCW from Major axis
Controlling Load Combo: 0.826 D + 1.300 E7 (LC 177)
Code Ref: 11.4.2.1

Shear Results:
Segment SC2H:47A:
Length = 4.15 m Thick = 400 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 23577.3 kgf phiVn = 229370.9 kgf OK
Controlling Load Combo: 1.274 D + 1.300 E16 (LC 114)
Code Ref: 11.5.4.5

Segment SC2H:47B:
Length = 5.40 m Thick = 400 mm f'c = 281 kg/cm2 fy = 4218 kg/cm2
Vert Bar Pat: #16@300 mm oc Horiz Bar Pat: #16@300 mm oc
Vu = 25071.8 kgf phiVnE105
= 298458.5 kgf OK
Section Cut Design Summary
RAM Concrete Shearwall 16.00.00.28 Page 2/2
John Rodrigues
Database: E - FIRE PUMP HOUSE 05/01/19 11:19:18
Design Code: ACI 318-14
Shear Results:
Controlling Load Combo: 1.274 D + 1.300 E17 (LC 115)
Code Ref: 11.5.4.5

Reinforcement Checks:
Min Vert Reinf Ratio: Limit: 0.250% Actual: 0.368% (11.6.2) OK
Segment SC2H:47A:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.335% Actual: 0.335% (18.10.4.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK
Segment SC2H:47B:
Max Vert Bar Spacing Limit: 457 mm Actual: 300 mm (11.7.2.1) OK
Min Vert Bar Spacing Limit: 25 mm Actual: 284 mm (25.2.1) OK
Min Longit Reinf Ratio Limit: 0.335% Actual: 0.335% (18.10.4.3) OK
Min Number of Reinf Curtains: 2 Actual: 2 (11.7.2.3) OK
Min Number of Reinf Curtains: 1 Actual: 2 (18.10.2.2) OK

E106
Foundation Model Data
RAM Foundation v16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:02:12

CONTINUOUS FOOTINGS GEOMETRY


Length (m) Width (Abs) (m)
Footing # Location (m) L1 L2 W1 W2 Thickness (m)
1 ( 0.20, 11.00) to ( 8.50, 11.00) 1.00(Abs) 1.00(Abs) 1.00 0.60 0.50(Abs)
2 ( 8.50, 0.20) to ( 8.50, 11.00) 0.75(Abs) 0.75(Abs) 0.60 1.00 0.50(Abs)
3 ( 0.20, 0.20) to ( 8.50, 0.20) 0.75(Abs) 0.75(Abs) 0.60 1.00 0.50(Abs)
4 ( 0.20, 0.20) to ( 0.20, 11.00) 0.60(Abs) 0.60(Abs) 1.00 0.60 0.50(Abs)

CONTINUOUS FOOTINGS MATERIAL PROPERTIES


Concrete Reinf. Soil Cap.(kg/m2)
Footing # f'c fct Density Type E fy or Table
(kg/cm2) (kg/cm2) (kg/m3) (kg/cm2) (kg/cm2)
1 281.23 CODE 2322.68 NW CODE 4218.49 11999.98
2 281.23 CODE 2322.68 NW CODE 4218.49 11999.98
3 281.23 CODE 2322.68 NW CODE 4218.49 11999.98
4 281.23 CODE 2322.68 NW CODE 4218.49 11999.98

CONTINUOUS FOOTINGS SUPPORTED MEMBERS


Column Base Plate(mm) Wall Location (m)
Footing # Location (m) Size Angle Length Width i End j End
1 (1' - C') C1 0.00 N/A N/A
(0.20, 11.00) 4150.00x400.00 -0.00 N/A N/A 0.20-11.00 11.00- 4.35
(4.35 - 11.00) C1 0.00 N/A N/A
(4.35, 11.00) 4150.00x400.00 0.00 N/A N/A 4.35-11.00 11.00- 8.50
(3' - C') C1 0.00 N/A N/A
2 (3' - A') C1 0.00 N/A N/A
(8.50, 0.20) 5399.99x400.00 90.00 N/A N/A 8.50- 0.20 0.20- 8.50
(8.50 - 5.60) C1 0.00 N/A N/A
(8.50, 5.60) 5399.99x400.00 90.00 N/A N/A 8.50- 5.60 5.60- 8.50
(3' - C') C1 0.00 N/A N/A
3 (1' - A') C1 0.00 N/A N/A
(0.20, 0.20) 4150.00x400.00 -0.00 N/A N/A 0.20- 0.20 0.20- 4.35
(4.35 - 0.20) C1 0.00 N/A N/A
(4.35, 0.20) 4150.00x400.00 0.00 N/A N/A 4.35- 0.20 0.20- 8.50
(3' - A') C1 0.00 N/A N/A
4 (1' - A') C1 0.00 N/A N/A
(0.20, 0.20) 5399.99x400.00 -90.00 N/A N/A 0.20- 0.20 0.20- 0.20
(0.20 - 5.60) C1 0.00 N/A N/A
(0.20, 5.60) 5399.99x400.00 90.00 N/A N/A 0.20- 5.60 5.60- 0.20
(1' - C') C1 0.00 N/A N/A

E107
Foundation Design Criteria
RAM Foundation v16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:02:12

REINFORCEMENT PROPERTIES TABLE: ramgb50010

CODE
ACI318-14
Check ACI 318-14 Sec 13.3.3.3.b (Center Strip Reinforcement)

FORCES
Forces in Gravity Members are Material Specific.
Forces on Gravity Steel members and Gravity 'Other' columns are from RAM Steel.
Forces on Gravity Concrete members and Gravity 'Other' walls are from RAM Concrete.

DESIGN METHOD
Footings designed based on soil capacity.
Design Pile Caps Based on Pile Load.

DESIGN OPTIONS
Include Moment Due to Shear in Column for Spread Footings True
Include Moment Due to Shear in Column for Continuous Footings True
Include Moment Due to Shear in Column for Pile Caps True
Include Spread Footing Self-Weight When Checking Soil Stress True
Keep Spread Footing Square During Optimization False
Increase Spread Footing Size to Prevent Uplift in Concrete Load Combinations True
Max Width to Depth Ratio for Design of Continuous Footing as Beam Not Defined

REINFORCEMENT
Clear Bar Spacing-Shear (mm) Max: CODE Min: CODE
Clear Bar Spacing-Flexure Max: CODE Min: CODE
(mm)
Reinforcement Ratio Max: CODE Min: CODE
Clear Bar Cover (mm) Top: CODE Bottom: CODE Side: CODE
Bar Sizes Considered - Shear: #20
Bar Sizes Considered - Flexure: #20

REINFORCEMENT SELECTION
Min. number of bars in footing 5
Keep all bars in spread footing layer the same True
Adjacent bars in continuous footing may differ in size by 1
Segment Spacing Increment (mm) 150.00
Shear Bar Spacing Increment (mm) 25.00
Selection Method Min reinf area
For Square Spread Footings Keep Same Quantity and Size Bars for Layer False

E108
Foundation Design Criteria
RAM Foundation v16.00.00.28 Page 2/2
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:02:12

OPTIMIZATION CRITERIA - SPREAD/CONTINUOUS


Min. Dimensions Edge of Base Plate to Edge of Footing (mm) 300.00
Min. Plan Dimensions (mm) 450.00
Pan Dimension Increment (mm) 150.00
Min. Thickness (mm) 500.00
Thickness Increment (mm) 50.00
Uplift Safety Factor Minimum Ratio 1.00

OPTIMIZATION CRITERIA - PILE/PILE CAP


Edge to Center of Pile Spacing is Maximum of:
Multiple of Pile Dimension 0.00
Edge to Center Distance (mm) 0.00
Clear from Face of Pile (mm) 150.00
Center to Center Spacing of Piles is Maximum of:
Multiple of Pile Dimension 3.00
Center to Center Distance (mm) 0.00
Clear from Face of Pile (mm) 0.00
Min. Thickness (mm) 500.00
Thickness Increment (mm) 150.00

PILE DEFINITIONS
Capacity
Label Diameter (mm) Compression (kgf) Tension (kgf) Shear (kgf)

PILE CONFIGURATION
Rows Parallel to
Label Major Minor
3 Pile Group 3 0
5 Pile Group 5 0
7 Pile Group 7 0
8 Pile Group 8 0
2 Pile Group 2 1
5 Pile Group Sqr. Cap 5 0

SOIL DEFINITIONS
Fixed Capacities (kg/m2) : 9832.38 ; 12052.78 ; 15000.02 ; 11999.98

E109
Load Combinations
RAM Foundation v16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44

LOAD CASE DEFINITIONS:


D Dead Load RAMUSER
Lp Live Load RAMUSER
Rfp Live Load Roof RAMUSER
W1 Wind Wind_ASCE710_1_X
W2 Wind Wind_ASCE710_1_Y
W3 Wind Wind_ASCE710_2_X+E
W4 Wind Wind_ASCE710_2_X-E
W5 Wind Wind_ASCE710_2_Y+E
W6 Wind Wind_ASCE710_2_Y-E
W7 Wind Wind_ASCE710_3_X+Y
W8 Wind Wind_ASCE710_3_X-Y
W9 Wind Wind_ASCE710_4_X+Y_CW
W10 Wind Wind_ASCE710_4_X+Y_CCW
W11 Wind Wind_ASCE710_4_X-Y_CW
W12 Wind Wind_ASCE710_4_X-Y_CCW
E1 Seismic EQ_ASCE710_X_+E_F
E2 Seismic EQ_ASCE710_X_-E_F
E3 Seismic EQ_ASCE710_Y_+E_F
E4 Seismic EQ_ASCE710_Y_-E_F
E5 Seismic EQ_ASCE710_X_+E_0.3Y_+E_
F
E6 Seismic EQ_ASCE710_X_+E_-0.3Y_+E_
F
E7 Seismic EQ_ASCE710_-X_+E_0.3Y_+E_
F
E8 Seismic EQ_ASCE710_-X_+E_-0.3Y_+E
_F
E9 Seismic EQ_ASCE710_0.3X_+E_Y_+E_
F
E10 Seismic EQ_ASCE710_0.3X_+E_-Y_+E_
F
E11 Seismic EQ_ASCE710_-0.3X_+E_Y_+E_
F
E12 Seismic EQ_ASCE710_-0.3X_+E_-Y_+E
_F
E13 Seismic EQ_ASCE710_X_+E_0.3Y_-E_F
E14 Seismic EQ_ASCE710_X_+E_-0.3Y_-E_
F
E15 Seismic EQ_ASCE710_-X_+E_0.3Y_-E_
F
E16 Seismic EQ_ASCE710_-X_+E_-0.3Y_-E_
F
E17 Seismic EQ_ASCE710_0.3X_+E_Y_-E_F
E18 Seismic EQ_ASCE710_0.3X_+E_-Y_-E_
F
E110
Load Combinations
RAM Foundation v16.00.00.28 Page 2/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
E19 Seismic EQ_ASCE710_-0.3X_+E_Y_-E_
F
E20 Seismic EQ_ASCE710_-0.3X_+E_-Y_-E_
F
E21 Seismic EQ_ASCE710_X_-E_0.3Y_+E_F
E22 Seismic EQ_ASCE710_X_-E_-0.3Y_+E_
F
E23 Seismic EQ_ASCE710_-X_-E_0.3Y_+E_
F
E24 Seismic EQ_ASCE710_-X_-E_-0.3Y_+E_
F
E25 Seismic EQ_ASCE710_0.3X_-E_Y_+E_F
E26 Seismic EQ_ASCE710_0.3X_-E_-Y_+E_
F
E27 Seismic EQ_ASCE710_-0.3X_-E_Y_+E_
F
E28 Seismic EQ_ASCE710_-0.3X_-E_-Y_+E_
F
E29 Seismic EQ_ASCE710_X_-E_0.3Y_-E_F
E30 Seismic EQ_ASCE710_X_-E_-0.3Y_-E_F
E31 Seismic EQ_ASCE710_-X_-E_0.3Y_-E_F
E32 Seismic EQ_ASCE710_-X_-E_-0.3Y_-E_
F
E33 Seismic EQ_ASCE710_0.3X_-E_Y_-E_F
E34 Seismic EQ_ASCE710_0.3X_-E_-Y_-E_F
E35 Seismic EQ_ASCE710_-0.3X_-E_Y_-E_F
E36 Seismic EQ_ASCE710_-0.3X_-E_-Y_-E_
F

CONCRETE COMBINATION CRITERIA:


Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Unreducible
Live Load factor f1 (0.5 or 0.500
1.0)
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300
GENERATED CONCRETE LOAD COMBINATIONS:
1 * 1.400 D
2 * 1.200 D + 1.600 Lp + 0.500 Rfp
3 * 1.200 D + 1.600 Lp
4 * 1.200 D + 0.500 Lp + 1.600 Rfp
5 * 1.200 D + 1.600 Rfp
6 * 1.200 D + 1.600 Rfp + 0.500 W1
7 * 1.200 D + 1.600 Rfp + 0.500 W2
8 * E111 W3
1.200 D + 1.600 Rfp + 0.500
Load Combinations
RAM Foundation v16.00.00.28 Page 3/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
9 * 1.200 D + 1.600 Rfp + 0.500 W4
10 * 1.200 D + 1.600 Rfp + 0.500 W5
11 * 1.200 D + 1.600 Rfp + 0.500 W6
12 * 1.200 D + 1.600 Rfp + 0.500 W7
13 * 1.200 D + 1.600 Rfp + 0.500 W8
14 * 1.200 D + 1.600 Rfp + 0.500 W9
15 * 1.200 D + 1.600 Rfp + 0.500 W10
16 * 1.200 D + 1.600 Rfp + 0.500 W11
17 * 1.200 D + 1.600 Rfp + 0.500 W12
18 * 1.200 D + 1.600 Rfp - 0.500 W1
19 * 1.200 D + 1.600 Rfp - 0.500 W2
20 * 1.200 D + 1.600 Rfp - 0.500 W3
21 * 1.200 D + 1.600 Rfp - 0.500 W4
22 * 1.200 D + 1.600 Rfp - 0.500 W5
23 * 1.200 D + 1.600 Rfp - 0.500 W6
24 * 1.200 D + 1.600 Rfp - 0.500 W7
25 * 1.200 D + 1.600 Rfp - 0.500 W8
26 * 1.200 D + 1.600 Rfp - 0.500 W9
27 * 1.200 D + 1.600 Rfp - 0.500 W10
28 * 1.200 D + 1.600 Rfp - 0.500 W11
29 * 1.200 D + 1.600 Rfp - 0.500 W12
30 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W1
31 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W2
32 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W3
33 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W4
34 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W5
35 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W6
36 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W7
37 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W8
38 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W9
39 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W10
40 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W11
41 * 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W12
42 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W1
43 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W2
44 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W3
45 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W4
46 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W5
47 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W6
48 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W7
49 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W8
50 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W9
51 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W10
52 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W11
53 * 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W12
54 * 1.200 D + 0.500 Lp + 1.000 W1
E112
Load Combinations
RAM Foundation v16.00.00.28 Page 4/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
55 * 1.200 D + 0.500 Lp + 1.000 W2
56 * 1.200 D + 0.500 Lp + 1.000 W3
57 * 1.200 D + 0.500 Lp + 1.000 W4
58 * 1.200 D + 0.500 Lp + 1.000 W5
59 * 1.200 D + 0.500 Lp + 1.000 W6
60 * 1.200 D + 0.500 Lp + 1.000 W7
61 * 1.200 D + 0.500 Lp + 1.000 W8
62 * 1.200 D + 0.500 Lp + 1.000 W9
63 * 1.200 D + 0.500 Lp + 1.000 W10
64 * 1.200 D + 0.500 Lp + 1.000 W11
65 * 1.200 D + 0.500 Lp + 1.000 W12
66 * 1.200 D + 0.500 Lp - 1.000 W1
67 * 1.200 D + 0.500 Lp - 1.000 W2
68 * 1.200 D + 0.500 Lp - 1.000 W3
69 * 1.200 D + 0.500 Lp - 1.000 W4
70 * 1.200 D + 0.500 Lp - 1.000 W5
71 * 1.200 D + 0.500 Lp - 1.000 W6
72 * 1.200 D + 0.500 Lp - 1.000 W7
73 * 1.200 D + 0.500 Lp - 1.000 W8
74 * 1.200 D + 0.500 Lp - 1.000 W9
75 * 1.200 D + 0.500 Lp - 1.000 W10
76 * 1.200 D + 0.500 Lp - 1.000 W11
77 * 1.200 D + 0.500 Lp - 1.000 W12
78 * 1.200 D + 0.500 Rfp + 1.000 W1
79 * 1.200 D + 0.500 Rfp + 1.000 W2
80 * 1.200 D + 0.500 Rfp + 1.000 W3
81 * 1.200 D + 0.500 Rfp + 1.000 W4
82 * 1.200 D + 0.500 Rfp + 1.000 W5
83 * 1.200 D + 0.500 Rfp + 1.000 W6
84 * 1.200 D + 0.500 Rfp + 1.000 W7
85 * 1.200 D + 0.500 Rfp + 1.000 W8
86 * 1.200 D + 0.500 Rfp + 1.000 W9
87 * 1.200 D + 0.500 Rfp + 1.000 W10
88 * 1.200 D + 0.500 Rfp + 1.000 W11
89 * 1.200 D + 0.500 Rfp + 1.000 W12
90 * 1.200 D + 0.500 Rfp - 1.000 W1
91 * 1.200 D + 0.500 Rfp - 1.000 W2
92 * 1.200 D + 0.500 Rfp - 1.000 W3
93 * 1.200 D + 0.500 Rfp - 1.000 W4
94 * 1.200 D + 0.500 Rfp - 1.000 W5
95 * 1.200 D + 0.500 Rfp - 1.000 W6
96 * 1.200 D + 0.500 Rfp - 1.000 W7
97 * 1.200 D + 0.500 Rfp - 1.000 W8
98 * 1.200 D + 0.500 Rfp - 1.000 W9
99 * 1.200 D + 0.500 Rfp - 1.000 W10
100 * 1.200 D + 0.500 Rfp - 1.000 W11
E113
Load Combinations
RAM Foundation v16.00.00.28 Page 5/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
101 * 1.200 D + 0.500 Rfp - 1.000 W12
102 * 1.200 D + 1.000 W1
103 * 1.200 D + 1.000 W2
104 * 1.200 D + 1.000 W3
105 * 1.200 D + 1.000 W4
106 * 1.200 D + 1.000 W5
107 * 1.200 D + 1.000 W6
108 * 1.200 D + 1.000 W7
109 * 1.200 D + 1.000 W8
110 * 1.200 D + 1.000 W9
111 * 1.200 D + 1.000 W10
112 * 1.200 D + 1.000 W11
113 * 1.200 D + 1.000 W12
114 * 1.200 D - 1.000 W1
115 * 1.200 D - 1.000 W2
116 * 1.200 D - 1.000 W3
117 * 1.200 D - 1.000 W4
118 * 1.200 D - 1.000 W5
119 * 1.200 D - 1.000 W6
120 * 1.200 D - 1.000 W7
121 * 1.200 D - 1.000 W8
122 * 1.200 D - 1.000 W9
123 * 1.200 D - 1.000 W10
124 * 1.200 D - 1.000 W11
125 * 1.200 D - 1.000 W12
126 * 0.900 D + 1.000 W1
127 * 0.900 D + 1.000 W2
128 * 0.900 D + 1.000 W3
129 * 0.900 D + 1.000 W4
130 * 0.900 D + 1.000 W5
131 * 0.900 D + 1.000 W6
132 * 0.900 D + 1.000 W7
133 * 0.900 D + 1.000 W8
134 * 0.900 D + 1.000 W9
135 * 0.900 D + 1.000 W10
136 * 0.900 D + 1.000 W11
137 * 0.900 D + 1.000 W12
138 * 0.900 D - 1.000 W1
139 * 0.900 D - 1.000 W2
140 * 0.900 D - 1.000 W3
141 * 0.900 D - 1.000 W4
142 * 0.900 D - 1.000 W5
143 * 0.900 D - 1.000 W6
144 * 0.900 D - 1.000 W7
145 * 0.900 D - 1.000 W8
146 * 0.900 D - 1.000 W9
E114
Load Combinations
RAM Foundation v16.00.00.28 Page 6/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
147 * 0.900 D - 1.000 W10
148 * 0.900 D - 1.000 W11
149 * 0.900 D - 1.000 W12
150 * 1.274 D + 0.500 Lp + 1.300 E1
151 * 1.274 D + 0.500 Lp + 1.300 E2
152 * 1.274 D + 0.500 Lp + 1.300 E3
153 * 1.274 D + 0.500 Lp + 1.300 E4
154 * 1.274 D + 0.500 Lp + 1.300 E5
155 * 1.274 D + 0.500 Lp + 1.300 E6
156 * 1.274 D + 0.500 Lp + 1.300 E7
157 * 1.274 D + 0.500 Lp + 1.300 E8
158 * 1.274 D + 0.500 Lp + 1.300 E9
159 * 1.274 D + 0.500 Lp + 1.300 E10
160 * 1.274 D + 0.500 Lp + 1.300 E11
161 * 1.274 D + 0.500 Lp + 1.300 E12
162 * 1.274 D + 0.500 Lp + 1.300 E13
163 * 1.274 D + 0.500 Lp + 1.300 E14
164 * 1.274 D + 0.500 Lp + 1.300 E15
165 * 1.274 D + 0.500 Lp + 1.300 E16
166 * 1.274 D + 0.500 Lp + 1.300 E17
167 * 1.274 D + 0.500 Lp + 1.300 E18
168 * 1.274 D + 0.500 Lp + 1.300 E19
169 * 1.274 D + 0.500 Lp + 1.300 E20
170 * 1.274 D + 0.500 Lp + 1.300 E21
171 * 1.274 D + 0.500 Lp + 1.300 E22
172 * 1.274 D + 0.500 Lp + 1.300 E23
173 * 1.274 D + 0.500 Lp + 1.300 E24
174 * 1.274 D + 0.500 Lp + 1.300 E25
175 * 1.274 D + 0.500 Lp + 1.300 E26
176 * 1.274 D + 0.500 Lp + 1.300 E27
177 * 1.274 D + 0.500 Lp + 1.300 E28
178 * 1.274 D + 0.500 Lp + 1.300 E29
179 * 1.274 D + 0.500 Lp + 1.300 E30
180 * 1.274 D + 0.500 Lp + 1.300 E31
181 * 1.274 D + 0.500 Lp + 1.300 E32
182 * 1.274 D + 0.500 Lp + 1.300 E33
183 * 1.274 D + 0.500 Lp + 1.300 E34
184 * 1.274 D + 0.500 Lp + 1.300 E35
185 * 1.274 D + 0.500 Lp + 1.300 E36
186 * 1.274 D + 0.500 Lp - 1.300 E1
187 * 1.274 D + 0.500 Lp - 1.300 E2
188 * 1.274 D + 0.500 Lp - 1.300 E3
189 * 1.274 D + 0.500 Lp - 1.300 E4
190 * 1.274 D + 0.500 Lp - 1.300 E5
191 * 1.274 D + 0.500 Lp - 1.300 E6
192 * 1.274 D + 0.500 Lp - 1.300 E7
E115
Load Combinations
RAM Foundation v16.00.00.28 Page 7/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
193 * 1.274 D + 0.500 Lp - 1.300 E8
194 * 1.274 D + 0.500 Lp - 1.300 E9
195 * 1.274 D + 0.500 Lp - 1.300 E10
196 * 1.274 D + 0.500 Lp - 1.300 E11
197 * 1.274 D + 0.500 Lp - 1.300 E12
198 * 1.274 D + 0.500 Lp - 1.300 E13
199 * 1.274 D + 0.500 Lp - 1.300 E14
200 * 1.274 D + 0.500 Lp - 1.300 E15
201 * 1.274 D + 0.500 Lp - 1.300 E16
202 * 1.274 D + 0.500 Lp - 1.300 E17
203 * 1.274 D + 0.500 Lp - 1.300 E18
204 * 1.274 D + 0.500 Lp - 1.300 E19
205 * 1.274 D + 0.500 Lp - 1.300 E20
206 * 1.274 D + 0.500 Lp - 1.300 E21
207 * 1.274 D + 0.500 Lp - 1.300 E22
208 * 1.274 D + 0.500 Lp - 1.300 E23
209 * 1.274 D + 0.500 Lp - 1.300 E24
210 * 1.274 D + 0.500 Lp - 1.300 E25
211 * 1.274 D + 0.500 Lp - 1.300 E26
212 * 1.274 D + 0.500 Lp - 1.300 E27
213 * 1.274 D + 0.500 Lp - 1.300 E28
214 * 1.274 D + 0.500 Lp - 1.300 E29
215 * 1.274 D + 0.500 Lp - 1.300 E30
216 * 1.274 D + 0.500 Lp - 1.300 E31
217 * 1.274 D + 0.500 Lp - 1.300 E32
218 * 1.274 D + 0.500 Lp - 1.300 E33
219 * 1.274 D + 0.500 Lp - 1.300 E34
220 * 1.274 D + 0.500 Lp - 1.300 E35
221 * 1.274 D + 0.500 Lp - 1.300 E36
222 * 1.274 D + 1.300 E1
223 * 1.274 D + 1.300 E2
224 * 1.274 D + 1.300 E3
225 * 1.274 D + 1.300 E4
226 * 1.274 D + 1.300 E5
227 * 1.274 D + 1.300 E6
228 * 1.274 D + 1.300 E7
229 * 1.274 D + 1.300 E8
230 * 1.274 D + 1.300 E9
231 * 1.274 D + 1.300 E10
232 * 1.274 D + 1.300 E11
233 * 1.274 D + 1.300 E12
234 * 1.274 D + 1.300 E13
235 * 1.274 D + 1.300 E14
236 * 1.274 D + 1.300 E15
237 * 1.274 D + 1.300 E16
238 * 1.274 D + 1.300 E17
E116
Load Combinations
RAM Foundation v16.00.00.28 Page 8/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
239 * 1.274 D + 1.300 E18
240 * 1.274 D + 1.300 E19
241 * 1.274 D + 1.300 E20
242 * 1.274 D + 1.300 E21
243 * 1.274 D + 1.300 E22
244 * 1.274 D + 1.300 E23
245 * 1.274 D + 1.300 E24
246 * 1.274 D + 1.300 E25
247 * 1.274 D + 1.300 E26
248 * 1.274 D + 1.300 E27
249 * 1.274 D + 1.300 E28
250 * 1.274 D + 1.300 E29
251 * 1.274 D + 1.300 E30
252 * 1.274 D + 1.300 E31
253 * 1.274 D + 1.300 E32
254 * 1.274 D + 1.300 E33
255 * 1.274 D + 1.300 E34
256 * 1.274 D + 1.300 E35
257 * 1.274 D + 1.300 E36
258 * 1.274 D - 1.300 E1
259 * 1.274 D - 1.300 E2
260 * 1.274 D - 1.300 E3
261 * 1.274 D - 1.300 E4
262 * 1.274 D - 1.300 E5
263 * 1.274 D - 1.300 E6
264 * 1.274 D - 1.300 E7
265 * 1.274 D - 1.300 E8
266 * 1.274 D - 1.300 E9
267 * 1.274 D - 1.300 E10
268 * 1.274 D - 1.300 E11
269 * 1.274 D - 1.300 E12
270 * 1.274 D - 1.300 E13
271 * 1.274 D - 1.300 E14
272 * 1.274 D - 1.300 E15
273 * 1.274 D - 1.300 E16
274 * 1.274 D - 1.300 E17
275 * 1.274 D - 1.300 E18
276 * 1.274 D - 1.300 E19
277 * 1.274 D - 1.300 E20
278 * 1.274 D - 1.300 E21
279 * 1.274 D - 1.300 E22
280 * 1.274 D - 1.300 E23
281 * 1.274 D - 1.300 E24
282 * 1.274 D - 1.300 E25
283 * 1.274 D - 1.300 E26
284 * 1.274 D - 1.300 E27
E117
Load Combinations
RAM Foundation v16.00.00.28 Page 9/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
285 * 1.274 D - 1.300 E28
286 * 1.274 D - 1.300 E29
287 * 1.274 D - 1.300 E30
288 * 1.274 D - 1.300 E31
289 * 1.274 D - 1.300 E32
290 * 1.274 D - 1.300 E33
291 * 1.274 D - 1.300 E34
292 * 1.274 D - 1.300 E35
293 * 1.274 D - 1.300 E36
294 * 0.826 D + 1.300 E1
295 * 0.826 D + 1.300 E2
296 * 0.826 D + 1.300 E3
297 * 0.826 D + 1.300 E4
298 * 0.826 D + 1.300 E5
299 * 0.826 D + 1.300 E6
300 * 0.826 D + 1.300 E7
301 * 0.826 D + 1.300 E8
302 * 0.826 D + 1.300 E9
303 * 0.826 D + 1.300 E10
304 * 0.826 D + 1.300 E11
305 * 0.826 D + 1.300 E12
306 * 0.826 D + 1.300 E13
307 * 0.826 D + 1.300 E14
308 * 0.826 D + 1.300 E15
309 * 0.826 D + 1.300 E16
310 * 0.826 D + 1.300 E17
311 * 0.826 D + 1.300 E18
312 * 0.826 D + 1.300 E19
313 * 0.826 D + 1.300 E20
314 * 0.826 D + 1.300 E21
315 * 0.826 D + 1.300 E22
316 * 0.826 D + 1.300 E23
317 * 0.826 D + 1.300 E24
318 * 0.826 D + 1.300 E25
319 * 0.826 D + 1.300 E26
320 * 0.826 D + 1.300 E27
321 * 0.826 D + 1.300 E28
322 * 0.826 D + 1.300 E29
323 * 0.826 D + 1.300 E30
324 * 0.826 D + 1.300 E31
325 * 0.826 D + 1.300 E32
326 * 0.826 D + 1.300 E33
327 * 0.826 D + 1.300 E34
328 * 0.826 D + 1.300 E35
329 * 0.826 D + 1.300 E36
330 * 0.826 D - 1.300 E1
E118
Load Combinations
RAM Foundation v16.00.00.28 Page 10/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
331 * 0.826 D - 1.300 E2
332 * 0.826 D - 1.300 E3
333 * 0.826 D - 1.300 E4
334 * 0.826 D - 1.300 E5
335 * 0.826 D - 1.300 E6
336 * 0.826 D - 1.300 E7
337 * 0.826 D - 1.300 E8
338 * 0.826 D - 1.300 E9
339 * 0.826 D - 1.300 E10
340 * 0.826 D - 1.300 E11
341 * 0.826 D - 1.300 E12
342 * 0.826 D - 1.300 E13
343 * 0.826 D - 1.300 E14
344 * 0.826 D - 1.300 E15
345 * 0.826 D - 1.300 E16
346 * 0.826 D - 1.300 E17
347 * 0.826 D - 1.300 E18
348 * 0.826 D - 1.300 E19
349 * 0.826 D - 1.300 E20
350 * 0.826 D - 1.300 E21
351 * 0.826 D - 1.300 E22
352 * 0.826 D - 1.300 E23
353 * 0.826 D - 1.300 E24
354 * 0.826 D - 1.300 E25
355 * 0.826 D - 1.300 E26
356 * 0.826 D - 1.300 E27
357 * 0.826 D - 1.300 E28
358 * 0.826 D - 1.300 E29
359 * 0.826 D - 1.300 E30
360 * 0.826 D - 1.300 E31
361 * 0.826 D - 1.300 E32
362 * 0.826 D - 1.300 E33
363 * 0.826 D - 1.300 E34
364 * 0.826 D - 1.300 E35
365 * 0.826 D - 1.300 E36
USER DEFINED CONCRETE LOAD COMBINATIONS:
366 * 1.400 D
367 1.200 D + 1.600 Lp + 0.500 Rfp
368 1.200 D + 1.600 Lp
369 1.200 D + 0.500 Lp + 1.600 Rfp
370 1.200 D + 1.600 Rfp
371 1.200 D + 1.600 Rfp + 0.500 W1
372 1.200 D + 1.600 Rfp + 0.500 W2
373 1.200 D + 1.600 Rfp + 0.500 W3
374 1.200 D + 1.600 Rfp + 0.500 W4
375 1.200 D + 1.600 Rfp + 0.500
E119 W5
Load Combinations
RAM Foundation v16.00.00.28 Page 11/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
376 1.200 D + 1.600 Rfp + 0.500 W6
377 1.200 D + 1.600 Rfp + 0.500 W7
378 1.200 D + 1.600 Rfp + 0.500 W8
379 1.200 D + 1.600 Rfp + 0.500 W9
380 1.200 D + 1.600 Rfp + 0.500 W10
381 1.200 D + 1.600 Rfp + 0.500 W11
382 1.200 D + 1.600 Rfp + 0.500 W12
383 1.200 D + 1.600 Rfp - 0.500 W1
384 1.200 D + 1.600 Rfp - 0.500 W2
385 1.200 D + 1.600 Rfp - 0.500 W3
386 1.200 D + 1.600 Rfp - 0.500 W4
387 1.200 D + 1.600 Rfp - 0.500 W5
388 1.200 D + 1.600 Rfp - 0.500 W6
389 1.200 D + 1.600 Rfp - 0.500 W7
390 1.200 D + 1.600 Rfp - 0.500 W8
391 1.200 D + 1.600 Rfp - 0.500 W9
392 1.200 D + 1.600 Rfp - 0.500 W10
393 1.200 D + 1.600 Rfp - 0.500 W11
394 1.200 D + 1.600 Rfp - 0.500 W12
395 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W1
396 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W2
397 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W3
398 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W4
399 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W5
400 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W6
401 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W7
402 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W8
403 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W9
404 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W10
405 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W11
406 1.200 D + 0.500 Lp + 0.500 Rfp + 1.000 W12
407 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W1
408 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W2
409 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W3
410 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W4
411 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W5
412 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W6
413 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W7
414 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W8
415 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W9
416 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W10
417 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W11
418 1.200 D + 0.500 Lp + 0.500 Rfp - 1.000 W12
419 1.200 D + 0.500 Lp + 1.000 W1
420 1.200 D + 0.500 Lp + 1.000 W2
421 1.200 D + 0.500 Lp + 1.000 W3
E120
Load Combinations
RAM Foundation v16.00.00.28 Page 12/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
422 1.200 D + 0.500 Lp + 1.000 W4
423 1.200 D + 0.500 Lp + 1.000 W5
424 1.200 D + 0.500 Lp + 1.000 W6
425 1.200 D + 0.500 Lp + 1.000 W7
426 1.200 D + 0.500 Lp + 1.000 W8
427 1.200 D + 0.500 Lp + 1.000 W9
428 1.200 D + 0.500 Lp + 1.000 W10
429 1.200 D + 0.500 Lp + 1.000 W11
430 1.200 D + 0.500 Lp + 1.000 W12
431 1.200 D + 0.500 Lp - 1.000 W1
432 1.200 D + 0.500 Lp - 1.000 W2
433 1.200 D + 0.500 Lp - 1.000 W3
434 1.200 D + 0.500 Lp - 1.000 W4
435 1.200 D + 0.500 Lp - 1.000 W5
436 1.200 D + 0.500 Lp - 1.000 W6
437 1.200 D + 0.500 Lp - 1.000 W7
438 1.200 D + 0.500 Lp - 1.000 W8
439 1.200 D + 0.500 Lp - 1.000 W9
440 1.200 D + 0.500 Lp - 1.000 W10
441 1.200 D + 0.500 Lp - 1.000 W11
442 1.200 D + 0.500 Lp - 1.000 W12
443 1.200 D + 0.500 Rfp + 1.000 W1
444 1.200 D + 0.500 Rfp + 1.000 W2
445 1.200 D + 0.500 Rfp + 1.000 W3
446 1.200 D + 0.500 Rfp + 1.000 W4
447 1.200 D + 0.500 Rfp + 1.000 W5
448 1.200 D + 0.500 Rfp + 1.000 W6
449 1.200 D + 0.500 Rfp + 1.000 W7
450 1.200 D + 0.500 Rfp + 1.000 W8
451 1.200 D + 0.500 Rfp + 1.000 W9
452 1.200 D + 0.500 Rfp + 1.000 W10
453 1.200 D + 0.500 Rfp + 1.000 W11
454 1.200 D + 0.500 Rfp + 1.000 W12
455 1.200 D + 0.500 Rfp - 1.000 W1
456 1.200 D + 0.500 Rfp - 1.000 W2
457 1.200 D + 0.500 Rfp - 1.000 W3
458 1.200 D + 0.500 Rfp - 1.000 W4
459 1.200 D + 0.500 Rfp - 1.000 W5
460 1.200 D + 0.500 Rfp - 1.000 W6
461 1.200 D + 0.500 Rfp - 1.000 W7
462 1.200 D + 0.500 Rfp - 1.000 W8
463 1.200 D + 0.500 Rfp - 1.000 W9
464 1.200 D + 0.500 Rfp - 1.000 W10
465 1.200 D + 0.500 Rfp - 1.000 W11
466 1.200 D + 0.500 Rfp - 1.000 W12
467 1.200 D + 1.000 W1
E121
Load Combinations
RAM Foundation v16.00.00.28 Page 13/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
468 1.200 D + 1.000 W2
469 1.200 D + 1.000 W3
470 1.200 D + 1.000 W4
471 1.200 D + 1.000 W5
472 1.200 D + 1.000 W6
473 1.200 D + 1.000 W7
474 1.200 D + 1.000 W8
475 1.200 D + 1.000 W9
476 1.200 D + 1.000 W10
477 1.200 D + 1.000 W11
478 1.200 D + 1.000 W12
479 1.200 D - 1.000 W1
480 1.200 D - 1.000 W2
481 1.200 D - 1.000 W3
482 1.200 D - 1.000 W4
483 1.200 D - 1.000 W5
484 1.200 D - 1.000 W6
485 1.200 D - 1.000 W7
486 1.200 D - 1.000 W8
487 1.200 D - 1.000 W9
488 1.200 D - 1.000 W10
489 1.200 D - 1.000 W11
490 1.200 D - 1.000 W12
491 0.900 D + 1.000 W1
492 0.900 D + 1.000 W2
493 0.900 D + 1.000 W3
494 0.900 D + 1.000 W4
495 0.900 D + 1.000 W5
496 0.900 D + 1.000 W6
497 0.900 D + 1.000 W7
498 0.900 D + 1.000 W8
499 0.900 D + 1.000 W9
500 0.900 D + 1.000 W10
501 0.900 D + 1.000 W11
502 0.900 D + 1.000 W12
503 0.900 D - 1.000 W1
504 0.900 D - 1.000 W2
505 0.900 D - 1.000 W3
506 0.900 D - 1.000 W4
507 0.900 D - 1.000 W5
508 0.900 D - 1.000 W6
509 0.900 D - 1.000 W7
510 0.900 D - 1.000 W8
511 0.900 D - 1.000 W9
512 0.900 D - 1.000 W10
513 0.900 D - 1.000 W11
E122
Load Combinations
RAM Foundation v16.00.00.28 Page 14/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
514 0.900 D - 1.000 W12
515 1.274 D + 0.500 Lp + 1.300 E1
516 1.274 D + 0.500 Lp + 1.300 E2
517 1.274 D + 0.500 Lp + 1.300 E3
518 1.274 D + 0.500 Lp + 1.300 E4
519 1.274 D + 0.500 Lp - 1.300 E1
520 1.274 D + 0.500 Lp - 1.300 E2
521 1.274 D + 0.500 Lp - 1.300 E3
522 1.274 D + 0.500 Lp - 1.300 E4
523 1.274 D + 1.300 E1
524 1.274 D + 1.300 E2
525 1.274 D + 1.300 E3
526 1.274 D + 1.300 E4
527 1.274 D - 1.300 E1
528 1.274 D - 1.300 E2
529 1.274 D - 1.300 E3
530 1.274 D - 1.300 E4
531 0.826 D + 1.300 E1
532 0.826 D + 1.300 E2
533 0.826 D + 1.300 E3
534 0.826 D + 1.300 E4
535 0.826 D - 1.300 E1
536 0.826 D - 1.300 E2
537 0.826 D - 1.300 E3
538 0.826 D - 1.300 E4

SOIL COMBINATION CRITERIA:


Combination Code: IBC 2012 / ASCE 7-10
Roof Live Load: Unreducible
Sds (for Ev) 0.371
RhoX 1.300
RhoY 1.300
GENERATED SOIL LOAD COMBINATIONS:
539 * 1.000 D
540 * 1.000 D + 1.000 Lp
541 * 1.000 D + 1.000 Rfp
542 * 1.000 D + 0.750 Lp + 0.750 Rfp
543 * 1.000 D + 0.600 W1
544 * 1.000 D + 0.600 W2
545 * 1.000 D + 0.600 W3
546 * 1.000 D + 0.600 W4
547 * 1.000 D + 0.600 W5
548 * 1.000 D + 0.600 W6
549 * 1.000 D + 0.600 W7
550 * 1.000 D + 0.600 W8
551 * 1.000 D + 0.600 W9 E123
Load Combinations
RAM Foundation v16.00.00.28 Page 15/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
552 * 1.000 D + 0.600 W10
553 * 1.000 D + 0.600 W11
554 * 1.000 D + 0.600 W12
555 * 1.000 D - 0.600 W1
556 * 1.000 D - 0.600 W2
557 * 1.000 D - 0.600 W3
558 * 1.000 D - 0.600 W4
559 * 1.000 D - 0.600 W5
560 * 1.000 D - 0.600 W6
561 * 1.000 D - 0.600 W7
562 * 1.000 D - 0.600 W8
563 * 1.000 D - 0.600 W9
564 * 1.000 D - 0.600 W10
565 * 1.000 D - 0.600 W11
566 * 1.000 D - 0.600 W12
567 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W1
568 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W2
569 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W3
570 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W4
571 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W5
572 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W6
573 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W7
574 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W8
575 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W9
576 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W10
577 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W11
578 * 1.000 D + 0.750 Lp + 0.750 Rfp + 0.450 W12
579 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W1
580 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W2
581 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W3
582 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W4
583 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W5
584 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W6
585 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W7
586 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W8
587 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W9
588 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W10
589 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W11
590 * 1.000 D + 0.750 Lp + 0.750 Rfp - 0.450 W12
591 * 1.000 D + 0.750 Lp + 0.450 W1
592 * 1.000 D + 0.750 Lp + 0.450 W2
593 * 1.000 D + 0.750 Lp + 0.450 W3
594 * 1.000 D + 0.750 Lp + 0.450 W4
595 * 1.000 D + 0.750 Lp + 0.450 W5
596 * 1.000 D + 0.750 Lp + 0.450 W6
597 * 1.000 D + 0.750 Lp + 0.450 W7
E124
Load Combinations
RAM Foundation v16.00.00.28 Page 16/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
598 * 1.000 D + 0.750 Lp + 0.450 W8
599 * 1.000 D + 0.750 Lp + 0.450 W9
600 * 1.000 D + 0.750 Lp + 0.450 W10
601 * 1.000 D + 0.750 Lp + 0.450 W11
602 * 1.000 D + 0.750 Lp + 0.450 W12
603 * 1.000 D + 0.750 Lp - 0.450 W1
604 * 1.000 D + 0.750 Lp - 0.450 W2
605 * 1.000 D + 0.750 Lp - 0.450 W3
606 * 1.000 D + 0.750 Lp - 0.450 W4
607 * 1.000 D + 0.750 Lp - 0.450 W5
608 * 1.000 D + 0.750 Lp - 0.450 W6
609 * 1.000 D + 0.750 Lp - 0.450 W7
610 * 1.000 D + 0.750 Lp - 0.450 W8
611 * 1.000 D + 0.750 Lp - 0.450 W9
612 * 1.000 D + 0.750 Lp - 0.450 W10
613 * 1.000 D + 0.750 Lp - 0.450 W11
614 * 1.000 D + 0.750 Lp - 0.450 W12
615 * 1.000 D + 0.750 Rfp + 0.450 W1
616 * 1.000 D + 0.750 Rfp + 0.450 W2
617 * 1.000 D + 0.750 Rfp + 0.450 W3
618 * 1.000 D + 0.750 Rfp + 0.450 W4
619 * 1.000 D + 0.750 Rfp + 0.450 W5
620 * 1.000 D + 0.750 Rfp + 0.450 W6
621 * 1.000 D + 0.750 Rfp + 0.450 W7
622 * 1.000 D + 0.750 Rfp + 0.450 W8
623 * 1.000 D + 0.750 Rfp + 0.450 W9
624 * 1.000 D + 0.750 Rfp + 0.450 W10
625 * 1.000 D + 0.750 Rfp + 0.450 W11
626 * 1.000 D + 0.750 Rfp + 0.450 W12
627 * 1.000 D + 0.750 Rfp - 0.450 W1
628 * 1.000 D + 0.750 Rfp - 0.450 W2
629 * 1.000 D + 0.750 Rfp - 0.450 W3
630 * 1.000 D + 0.750 Rfp - 0.450 W4
631 * 1.000 D + 0.750 Rfp - 0.450 W5
632 * 1.000 D + 0.750 Rfp - 0.450 W6
633 * 1.000 D + 0.750 Rfp - 0.450 W7
634 * 1.000 D + 0.750 Rfp - 0.450 W8
635 * 1.000 D + 0.750 Rfp - 0.450 W9
636 * 1.000 D + 0.750 Rfp - 0.450 W10
637 * 1.000 D + 0.750 Rfp - 0.450 W11
638 * 1.000 D + 0.750 Rfp - 0.450 W12
639 * 0.600 D + 0.600 W1
640 * 0.600 D + 0.600 W2
641 * 0.600 D + 0.600 W3
642 * 0.600 D + 0.600 W4
643 * 0.600 D + 0.600 W5
E125
Load Combinations
RAM Foundation v16.00.00.28 Page 17/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
644 * 0.600 D + 0.600 W6
645 * 0.600 D + 0.600 W7
646 * 0.600 D + 0.600 W8
647 * 0.600 D + 0.600 W9
648 * 0.600 D + 0.600 W10
649 * 0.600 D + 0.600 W11
650 * 0.600 D + 0.600 W12
651 * 0.600 D - 0.600 W1
652 * 0.600 D - 0.600 W2
653 * 0.600 D - 0.600 W3
654 * 0.600 D - 0.600 W4
655 * 0.600 D - 0.600 W5
656 * 0.600 D - 0.600 W6
657 * 0.600 D - 0.600 W7
658 * 0.600 D - 0.600 W8
659 * 0.600 D - 0.600 W9
660 * 0.600 D - 0.600 W10
661 * 0.600 D - 0.600 W11
662 * 0.600 D - 0.600 W12
663 * 1.052 D + 0.910 E1
664 * 1.052 D + 0.910 E2
665 * 1.052 D + 0.910 E3
666 * 1.052 D + 0.910 E4
667 * 1.052 D + 0.910 E5
668 * 1.052 D + 0.910 E6
669 * 1.052 D + 0.910 E7
670 * 1.052 D + 0.910 E8
671 * 1.052 D + 0.910 E9
672 * 1.052 D + 0.910 E10
673 * 1.052 D + 0.910 E11
674 * 1.052 D + 0.910 E12
675 * 1.052 D + 0.910 E13
676 * 1.052 D + 0.910 E14
677 * 1.052 D + 0.910 E15
678 * 1.052 D + 0.910 E16
679 * 1.052 D + 0.910 E17
680 * 1.052 D + 0.910 E18
681 * 1.052 D + 0.910 E19
682 * 1.052 D + 0.910 E20
683 * 1.052 D + 0.910 E21
684 * 1.052 D + 0.910 E22
685 * 1.052 D + 0.910 E23
686 * 1.052 D + 0.910 E24
687 * 1.052 D + 0.910 E25
688 * 1.052 D + 0.910 E26
689 * 1.052 D + 0.910 E27
E126
Load Combinations
RAM Foundation v16.00.00.28 Page 18/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
690 * 1.052 D + 0.910 E28
691 * 1.052 D + 0.910 E29
692 * 1.052 D + 0.910 E30
693 * 1.052 D + 0.910 E31
694 * 1.052 D + 0.910 E32
695 * 1.052 D + 0.910 E33
696 * 1.052 D + 0.910 E34
697 * 1.052 D + 0.910 E35
698 * 1.052 D + 0.910 E36
699 * 1.052 D - 0.910 E1
700 * 1.052 D - 0.910 E2
701 * 1.052 D - 0.910 E3
702 * 1.052 D - 0.910 E4
703 * 1.052 D - 0.910 E5
704 * 1.052 D - 0.910 E6
705 * 1.052 D - 0.910 E7
706 * 1.052 D - 0.910 E8
707 * 1.052 D - 0.910 E9
708 * 1.052 D - 0.910 E10
709 * 1.052 D - 0.910 E11
710 * 1.052 D - 0.910 E12
711 * 1.052 D - 0.910 E13
712 * 1.052 D - 0.910 E14
713 * 1.052 D - 0.910 E15
714 * 1.052 D - 0.910 E16
715 * 1.052 D - 0.910 E17
716 * 1.052 D - 0.910 E18
717 * 1.052 D - 0.910 E19
718 * 1.052 D - 0.910 E20
719 * 1.052 D - 0.910 E21
720 * 1.052 D - 0.910 E22
721 * 1.052 D - 0.910 E23
722 * 1.052 D - 0.910 E24
723 * 1.052 D - 0.910 E25
724 * 1.052 D - 0.910 E26
725 * 1.052 D - 0.910 E27
726 * 1.052 D - 0.910 E28
727 * 1.052 D - 0.910 E29
728 * 1.052 D - 0.910 E30
729 * 1.052 D - 0.910 E31
730 * 1.052 D - 0.910 E32
731 * 1.052 D - 0.910 E33
732 * 1.052 D - 0.910 E34
733 * 1.052 D - 0.910 E35
734 * 1.052 D - 0.910 E36
735 * 1.039 D + 0.750 Lp + 0.683 E1
E127
Load Combinations
RAM Foundation v16.00.00.28 Page 19/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
736 * 1.039 D + 0.750 Lp + 0.683 E2
737 * 1.039 D + 0.750 Lp + 0.683 E3
738 * 1.039 D + 0.750 Lp + 0.683 E4
739 * 1.039 D + 0.750 Lp + 0.683 E5
740 * 1.039 D + 0.750 Lp + 0.683 E6
741 * 1.039 D + 0.750 Lp + 0.683 E7
742 * 1.039 D + 0.750 Lp + 0.683 E8
743 * 1.039 D + 0.750 Lp + 0.683 E9
744 * 1.039 D + 0.750 Lp + 0.683 E10
745 * 1.039 D + 0.750 Lp + 0.683 E11
746 * 1.039 D + 0.750 Lp + 0.683 E12
747 * 1.039 D + 0.750 Lp + 0.683 E13
748 * 1.039 D + 0.750 Lp + 0.683 E14
749 * 1.039 D + 0.750 Lp + 0.683 E15
750 * 1.039 D + 0.750 Lp + 0.683 E16
751 * 1.039 D + 0.750 Lp + 0.683 E17
752 * 1.039 D + 0.750 Lp + 0.683 E18
753 * 1.039 D + 0.750 Lp + 0.683 E19
754 * 1.039 D + 0.750 Lp + 0.683 E20
755 * 1.039 D + 0.750 Lp + 0.683 E21
756 * 1.039 D + 0.750 Lp + 0.683 E22
757 * 1.039 D + 0.750 Lp + 0.683 E23
758 * 1.039 D + 0.750 Lp + 0.683 E24
759 * 1.039 D + 0.750 Lp + 0.683 E25
760 * 1.039 D + 0.750 Lp + 0.683 E26
761 * 1.039 D + 0.750 Lp + 0.683 E27
762 * 1.039 D + 0.750 Lp + 0.683 E28
763 * 1.039 D + 0.750 Lp + 0.683 E29
764 * 1.039 D + 0.750 Lp + 0.683 E30
765 * 1.039 D + 0.750 Lp + 0.683 E31
766 * 1.039 D + 0.750 Lp + 0.683 E32
767 * 1.039 D + 0.750 Lp + 0.683 E33
768 * 1.039 D + 0.750 Lp + 0.683 E34
769 * 1.039 D + 0.750 Lp + 0.683 E35
770 * 1.039 D + 0.750 Lp + 0.683 E36
771 * 1.039 D + 0.750 Lp - 0.683 E1
772 * 1.039 D + 0.750 Lp - 0.683 E2
773 * 1.039 D + 0.750 Lp - 0.683 E3
774 * 1.039 D + 0.750 Lp - 0.683 E4
775 * 1.039 D + 0.750 Lp - 0.683 E5
776 * 1.039 D + 0.750 Lp - 0.683 E6
777 * 1.039 D + 0.750 Lp - 0.683 E7
778 * 1.039 D + 0.750 Lp - 0.683 E8
779 * 1.039 D + 0.750 Lp - 0.683 E9
780 * 1.039 D + 0.750 Lp - 0.683 E10
781 * 1.039 D + 0.750 Lp - 0.683 E11
E128
Load Combinations
RAM Foundation v16.00.00.28 Page 20/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
782 * 1.039 D + 0.750 Lp - 0.683 E12
783 * 1.039 D + 0.750 Lp - 0.683 E13
784 * 1.039 D + 0.750 Lp - 0.683 E14
785 * 1.039 D + 0.750 Lp - 0.683 E15
786 * 1.039 D + 0.750 Lp - 0.683 E16
787 * 1.039 D + 0.750 Lp - 0.683 E17
788 * 1.039 D + 0.750 Lp - 0.683 E18
789 * 1.039 D + 0.750 Lp - 0.683 E19
790 * 1.039 D + 0.750 Lp - 0.683 E20
791 * 1.039 D + 0.750 Lp - 0.683 E21
792 * 1.039 D + 0.750 Lp - 0.683 E22
793 * 1.039 D + 0.750 Lp - 0.683 E23
794 * 1.039 D + 0.750 Lp - 0.683 E24
795 * 1.039 D + 0.750 Lp - 0.683 E25
796 * 1.039 D + 0.750 Lp - 0.683 E26
797 * 1.039 D + 0.750 Lp - 0.683 E27
798 * 1.039 D + 0.750 Lp - 0.683 E28
799 * 1.039 D + 0.750 Lp - 0.683 E29
800 * 1.039 D + 0.750 Lp - 0.683 E30
801 * 1.039 D + 0.750 Lp - 0.683 E31
802 * 1.039 D + 0.750 Lp - 0.683 E32
803 * 1.039 D + 0.750 Lp - 0.683 E33
804 * 1.039 D + 0.750 Lp - 0.683 E34
805 * 1.039 D + 0.750 Lp - 0.683 E35
806 * 1.039 D + 0.750 Lp - 0.683 E36
807 * 0.600 D + 0.910 E1
808 * 0.600 D + 0.910 E2
809 * 0.600 D + 0.910 E3
810 * 0.600 D + 0.910 E4
811 * 0.600 D + 0.910 E5
812 * 0.600 D + 0.910 E6
813 * 0.600 D + 0.910 E7
814 * 0.600 D + 0.910 E8
815 * 0.600 D + 0.910 E9
816 * 0.600 D + 0.910 E10
817 * 0.600 D + 0.910 E11
818 * 0.600 D + 0.910 E12
819 * 0.600 D + 0.910 E13
820 * 0.600 D + 0.910 E14
821 * 0.600 D + 0.910 E15
822 * 0.600 D + 0.910 E16
823 * 0.600 D + 0.910 E17
824 * 0.600 D + 0.910 E18
825 * 0.600 D + 0.910 E19
826 * 0.600 D + 0.910 E20
827 * 0.600 D + 0.910 E21
E129
Load Combinations
RAM Foundation v16.00.00.28 Page 21/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
828 * 0.600 D + 0.910 E22
829 * 0.600 D + 0.910 E23
830 * 0.600 D + 0.910 E24
831 * 0.600 D + 0.910 E25
832 * 0.600 D + 0.910 E26
833 * 0.600 D + 0.910 E27
834 * 0.600 D + 0.910 E28
835 * 0.600 D + 0.910 E29
836 * 0.600 D + 0.910 E30
837 * 0.600 D + 0.910 E31
838 * 0.600 D + 0.910 E32
839 * 0.600 D + 0.910 E33
840 * 0.600 D + 0.910 E34
841 * 0.600 D + 0.910 E35
842 * 0.600 D + 0.910 E36
843 * 0.600 D - 0.910 E1
844 * 0.600 D - 0.910 E2
845 * 0.600 D - 0.910 E3
846 * 0.600 D - 0.910 E4
847 * 0.600 D - 0.910 E5
848 * 0.600 D - 0.910 E6
849 * 0.600 D - 0.910 E7
850 * 0.600 D - 0.910 E8
851 * 0.600 D - 0.910 E9
852 * 0.600 D - 0.910 E10
853 * 0.600 D - 0.910 E11
854 * 0.600 D - 0.910 E12
855 * 0.600 D - 0.910 E13
856 * 0.600 D - 0.910 E14
857 * 0.600 D - 0.910 E15
858 * 0.600 D - 0.910 E16
859 * 0.600 D - 0.910 E17
860 * 0.600 D - 0.910 E18
861 * 0.600 D - 0.910 E19
862 * 0.600 D - 0.910 E20
863 * 0.600 D - 0.910 E21
864 * 0.600 D - 0.910 E22
865 * 0.600 D - 0.910 E23
866 * 0.600 D - 0.910 E24
867 * 0.600 D - 0.910 E25
868 * 0.600 D - 0.910 E26
869 * 0.600 D - 0.910 E27
870 * 0.600 D - 0.910 E28
871 * 0.600 D - 0.910 E29
872 * 0.600 D - 0.910 E30
873 * 0.600 D - 0.910 E31
E130
Load Combinations
RAM Foundation v16.00.00.28 Page 22/22
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
874 * 0.600 D - 0.910 E32
875 * 0.600 D - 0.910 E33
876 * 0.600 D - 0.910 E34
877 * 0.600 D - 0.910 E35
878 * 0.600 D - 0.910 E36
* = Load combination currently selected to use

E131
RAM Structural System V16.00.00.28.
John Rodrigues

DataBase: E - FIRE PUMP HOUSE 04/25/19 15:32:23

1
C: 12 3

C
C'

C: 4 C: 2

C: 3
A'
A
1' 3'

E132
Continuous Foundation Design
RAM Foundation v16.00.00.28
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 1
Length (m): 10.30
Width (m): 1.60 (w1 = 1.00 w2 = 0.60)
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 5.10 H/S 5-#20
2 5.10/10.30 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/10.30 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.45 None 2-#20
2 0.45/ 1.13 None 3-#20
3 1.13/ 5.03 None 12-#20
4 5.03/ 5.70 None 3-#20
5 5.70/ 8.85 None 10-#20
6 8.85/ 9.75 None 3-#20
7 9.75/10.30 None 2-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.39 Not Applic. None
2 9.91/10.30 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20

E133
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 2/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - C') 1.00 C1 0.00 N/A 0
(4.35 - 11.00) 5.15 C1 0.00 N/A 0
(3' - C') 9.30 C1 0.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.20, 11.00) to (4.35, 11.00) 3.07 4150.00x400.00 Wall 0.00
(4.35, 11.00) to (8.50, 11.00) 7.22 4150.00x400.00 Wall -0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 7817.92 192 9.91
Provided Shear (kgf) 44163.13 9.91
Req. Max Pos. Moment (kg.m) 5912.77 184 0.80 10678.36 166 1.13
Provided Pos. Moment (kg.m) 24004.00 0.80 52556.04 1.13
Req. Max Neg. Moment (kg.m) -0.00 1 10.30 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25512.71 10.30 -0.00 0.00
Req. Max Punching Shear (kgf) 91570.42 155 3.07
Provided Punching Shear (kgf) 390546.34 3.07
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 7143.6 Ld Co # 675
Max Average Unfactored Soil Bearing (kg/m2) 6986.8

E134
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 3/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 2
Length (m): 12.30
Width (m): 1.60 (w1 = 0.60 w2 = 1.00)
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 6.15 H/S 5-#20
2 6.15/12.30 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/12.30 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.30 None 1-#20
2 0.30/ 0.83 None 2-#20
3 0.83/ 6.08 None 16-#20
4 6.08/ 6.60 None 2-#20
5 6.60/11.10 None 14-#20
6 11.10/12.00 None 3-#20
7 12.00/12.30 None 1-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.16 Not Applic. None
2 12.14/12.30 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20

E135
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 4/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(3' - A') 0.75 C1 90.00 N/A 0
(8.50 - 5.60) 6.15 C1 90.00 N/A 0
(3' - C') 11.55 C1 90.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(8.50, 0.20) to (8.50, 5.60) 3.45 5399.99x400.00 Wall 0.00
(8.50, 5.60) to (8.50, 11.00) 8.85 5399.99x400.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 4523.89 216 0.14
Provided Shear (kgf) 44163.13 0.14
Req. Max Pos. Moment (kg.m) 2828.70 216 0.55 16114.39 216 0.83
Provided Pos. Moment (kg.m) 24004.00 0.55 70089.42 0.83
Req. Max Neg. Moment (kg.m) -0.00 143 0.00 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25512.71 0.00 -0.00 0.00
Req. Max Punching Shear (kgf) 108057.55 160 3.45
Provided Punching Shear (kgf) 454595.26 3.45
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 8379.8 Ld Co # 729
Max Average Unfactored Soil Bearing (kg/m2) 7459.0

E136
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 5/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 3
Length (m): 9.80
Width (m): 1.60 (w1 = 0.60 w2 = 1.00)
Thickness (m): 0.50
Footing Orientation (deg): 0.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 4.95 H/S 5-#20
2 4.95/ 9.80 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/ 9.80 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.30 None 1-#20
2 0.30/ 0.83 None 2-#20
3 0.83/ 4.80 None 12-#20
4 4.80/ 5.40 None 2-#20
5 5.40/ 8.55 None 10-#20
6 8.55/ 9.60 None 4-#20
7 9.60/ 9.80 None 1-#20

Longitudinal Shear Reinforcement:


Number of Shear bar legs: 2
Seg. Segment Spacing
Num. Start/End (m) (mm) Quantity
1 0.00/ 0.16 Not Applic. None
2 9.64/ 9.80 Not Applic. None
Cover (mm) Top 50.80 Bottom 76.20 Side 76.20

E137
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 6/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - A') 0.75 C1 0.00 N/A 0
(4.35 - 0.20) 4.90 C1 0.00 N/A 0
(3' - A') 9.05 C1 0.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.20, 0.20) to (4.35, 0.20) 2.83 4150.00x400.00 Wall 0.00
(4.35, 0.20) to (8.50, 0.20) 6.98 4150.00x400.00 Wall -0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 3956.11 180 0.14
Provided Shear (kgf) 44163.13 0.14
Req. Max Pos. Moment (kg.m) 2598.88 159 9.25 11741.30 180 0.83
Provided Pos. Moment (kg.m) 24004.00 9.25 52577.89 0.83
Req. Max Neg. Moment (kg.m) -0.00 316 0.00 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25512.71 0.00 -0.00 0.00
Req. Max Punching Shear (kgf) 92823.82 180 6.98
Provided Punching Shear (kgf) 390546.34 6.98
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 7860.6 Ld Co # 672
Max Average Unfactored Soil Bearing (kg/m2) 7509.4

E138
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 7/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14

FOOTING DESIGN
Footing # 4
Length (m): 12.00
Width (m): 1.60 (w1 = 1.00 w2 = 0.60)
Thickness (m): 0.50
Footing Orientation (deg): 90.00º
Concrete f'c (kg/cm2): 281.23 fct (kg/cm2): CODE Density (kg/m3): 2322.68 Ec (kg/cm2): 256213.07
Reinf. fy (kg/cm2): 4218.49
LOADS
Surcharge (kg/m2) Dead Load: 0.00 Live Load: 0.00
REINFORCEMENT
Top Longitudinal Flexure Reinforcement:
Bar Depth (mm) 439.23
Seg. Spacing Bar End Condition Top Bars
Num. Start/End (m) Start/End
1 0.00/ 6.00 H/S 5-#20
2 6.00/12.00 S/H 5-#20

Bottom Longitudinal Flexure Reinforcement:


Bar Depth (mm) 413.83
Seg. Spacing Bar End Condition Bot. Bars
Num. Start/End (m) Start/End
1 0.00/12.00 H/H 5-#20

Transverse Flexure Reinforcement:


Top Bar Depth (mm) 429.26 Bottom Bar Depth (mm) 393.89
Seg. Segment Top Bars Bot. Bars
Num. Start/End (m)
1 0.00/ 0.15 None 1-#20
2 0.15/ 0.68 None 2-#20
3 0.68/ 5.93 None 16-#20
4 5.93/ 6.45 None 2-#20
5 6.45/10.95 None 14-#20
6 10.95/11.85 None 3-#20
7 11.85/12.00 None 1-#20

Longitudinal Shear Reinforcement:


No Shear Reinforcement Required.
SUPPORTED MEMBERS
Columns:
Loc. Along Column Base Plate %
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - A') 0.60 C1 90.00 N/A 0
(0.20 - 5.60) 6.00 C1 90.00 N/A 0
E139
Continuous Foundation Design
RAM Foundation v16.00.00.28 Page 8/8
John Rodrigues
DataBase: E - FIRE PUMP HOUSE Date: 05/01/19 12:04:44
Building Code: IBC Design Code: ACI318-14
Location Footing (m): Size Orientation (LxW) (mm): Rigid
(1' - C') 11.40 C1 90.00 N/A 0

Walls:
Loc. Along Size
Wall Location (m): Footing (m): (LxW) (mm): Type Orientation
(0.20, 0.20) to (0.20, 5.60) 3.30 5399.99x400.00 Wall 180.00
(0.20, 5.60) to (0.20, 11.00) 8.70 5399.99x400.00 Wall 0.00
CONCRETE CAPACITY
Longitudinal Ld Co # Loc. (m) Transvers Ld Co # Loc. (m)
Req. Max Shear (kgf) 0.00 -1 0.00
Provided Shear (kgf) 0.00 0.00
Req. Max Pos. Moment (kg.m) 1684.35 156 11.60 14705.90 183 0.68
Provided Pos. Moment (kg.m) 24004.00 11.60 70089.42 0.68
Req. Max Neg. Moment (kg.m) -0.00 177 0.00 -0.00 -1 0.00
Provided Neg. Moment (kg.m) -25512.71 0.00 -0.00 0.00
Req. Max Punching Shear (kgf) 102664.64 183 8.70
Provided Punching Shear (kgf) 454595.26 8.70
SOIL CAPACITY
Allowable Soil Bearing Capacity (kg/m2) 12000.0
Soil Subgrade Modulus (kg/m2 / m) 944868.9
Max Unfactored Soil Bearing (kg/m2) 8469.9 Ld Co # 669
Max Average Unfactored Soil Bearing (kg/m2) 7503.3

E140
E141
Two-Way Slab Design

Job = RSLF - ARTILLERY BRIGADE 127-269162-19001 Designer JSR Date 5/7/2019


Building = Fire Pump House FPH Checker Date

STAAD | Nodes & Plates

X = 4100 mm (13.4 ft)


Cl of Beam to Cl of Beam

Exterior Beam B1: W = 500mm (1.64ft )


Interior Beam B3: W = 600mm (1.968ft )

Exterior Beam B4: W = 500mm (1.64ft )

Z_cs = 4800 mm Say --> 16 ft


Cl of Beam to Cl of Beam

Clear Span
Z = 5350 mm (17.5 ft)

Clear Span
Clear Span
B4

B5
Z

Interior Beam B2: W = 600mm (1.968ft )

X_cs = 3550 mm Say --> 12 ft


Clear Span

Cl to Cl Span
X= 4100 mm 13.40 ft
Z= 5350 mm 17.50 ft

Beam Width Cl to Interior Face


Beam Location W (mm) W (ft) (mm) (ft)
B1 Exterior 500 1.64 250 0.82
B2 Interior 600 1.97 300 0.98
B3 Interior 600 1.97 300 0.98
B4 Exterior 500 1.64 250 0.82

Clear Span
X_cs = 3550 mm 11.60 ft SAY --> X_cs = 12.00 ft
Z_cs = 4800 mm 15.70 ft Z_cs = 16.00 ft

Number of Nodes = 221


Number of Plates = 192

LOADS (Facilities with the maximum loads were used)

E142 PAGE 1 OF 2
Dead Loads

HVAC (Minor) = 10.00 psf 0.01 ksf


Collateral Dead Load = 10.00 psf 0.01 ksf
Roof Topping = 65.00 psf 0.07 ksf

Total Dead Load = 85.00 psf 0.09 ksf

Live Loads
Roof Live Load = 20.00 psf 0.02 ksf

E143 PAGE 2 OF 2
Job No Sheet No Rev
127-269162-19001 1
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Job Information
Engineer Checked Approved

Name: JSR
Date: 06-May-19

Structure Type SPACE FRAME

Number of Nodes 221 Highest Node 221


Number of Plates 192 Highest Plate 192

Number of Basic Load Cases 2


Number of Combination Load Cases 5

Included in this printout are data for:


All The Whole Structure

Included in this printout are results for load cases:


Type L/C Name

Primary 1 DL
Primary 2 RLL
Combination 3 GENERATED ACI TABLE1 1
Combination 4 GENERATED ACI TABLE1 2
Combination 5 GENERATED ACI TABLE1 3
Combination 6 GENERATED ACI TABLE1 4
Combination 7 GENERATED ACI TABLE1 5

Materials
Mat Name E ν Density α
(kip/in2) (kip/in3) (/°F)
1 STEEL 29E+3 0.300 0.000 6E -6
2 STAINLESSSTEEL 28E+3 0.300 0.000 10E -6
3 ALUMINUM 10E+3 0.330 0.000 13E -6
4 CONCRETE 3.15E+3 0.170 0.000 5E -6

Plate Thickness
Prop Node A Node B Node C Node D Material
(in) (in) (in) (in)
1 7.884 7.884 7.884 7.884 CONCRETE

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 8

E144
Job No Sheet No Rev
127-269162-19001 2
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Plates
Plate Node A Node B Node C Node D Property

1 1 2 19 18 1
2 2 3 20 19 1
3 3 4 21 20 1
4 4 5 22 21 1
5 5 6 23 22 1
6 6 7 24 23 1
7 7 8 25 24 1
8 8 9 26 25 1
9 9 10 27 26 1
10 10 11 28 27 1
11 11 12 29 28 1
12 12 13 30 29 1
13 13 14 31 30 1
14 14 15 32 31 1
15 15 16 33 32 1
16 16 17 34 33 1
17 18 19 36 35 1
18 19 20 37 36 1
19 20 21 38 37 1
20 21 22 39 38 1
21 22 23 40 39 1
22 23 24 41 40 1
23 24 25 42 41 1
24 25 26 43 42 1
25 26 27 44 43 1
26 27 28 45 44 1
27 28 29 46 45 1
28 29 30 47 46 1
29 30 31 48 47 1
30 31 32 49 48 1
31 32 33 50 49 1
32 33 34 51 50 1
33 35 36 53 52 1
34 36 37 54 53 1
35 37 38 55 54 1
36 38 39 56 55 1
37 39 40 57 56 1
38 40 41 58 57 1
39 41 42 59 58 1
40 42 43 60 59 1
41 43 44 61 60 1
42 44 45 62 61 1
43 45 46 63 62 1
44 46 47 64 63 1
45 47 48 65 64 1

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 2 of 8

E145
Job No Sheet No Rev
127-269162-19001 3
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Plates Cont...
Plate Node A Node B Node C Node D Property

46 48 49 66 65 1
47 49 50 67 66 1
48 50 51 68 67 1
49 52 53 70 69 1
50 53 54 71 70 1
51 54 55 72 71 1
52 55 56 73 72 1
53 56 57 74 73 1
54 57 58 75 74 1
55 58 59 76 75 1
56 59 60 77 76 1
57 60 61 78 77 1
58 61 62 79 78 1
59 62 63 80 79 1
60 63 64 81 80 1
61 64 65 82 81 1
62 65 66 83 82 1
63 66 67 84 83 1
64 67 68 85 84 1
65 69 70 87 86 1
66 70 71 88 87 1
67 71 72 89 88 1
68 72 73 90 89 1
69 73 74 91 90 1
70 74 75 92 91 1
71 75 76 93 92 1
72 76 77 94 93 1
73 77 78 95 94 1
74 78 79 96 95 1
75 79 80 97 96 1
76 80 81 98 97 1
77 81 82 99 98 1
78 82 83 100 99 1
79 83 84 101 100 1
80 84 85 102 101 1
81 86 87 104 103 1
82 87 88 105 104 1
83 88 89 106 105 1
84 89 90 107 106 1
85 90 91 108 107 1
86 91 92 109 108 1
87 92 93 110 109 1
88 93 94 111 110 1
89 94 95 112 111 1
90 95 96 113 112 1

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 3 of 8

E146
Job No Sheet No Rev
127-269162-19001 4
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Plates Cont...
Plate Node A Node B Node C Node D Property

91 96 97 114 113 1
92 97 98 115 114 1
93 98 99 116 115 1
94 99 100 117 116 1
95 100 101 118 117 1
96 101 102 119 118 1
97 103 104 121 120 1
98 104 105 122 121 1
99 105 106 123 122 1
100 106 107 124 123 1
101 107 108 125 124 1
102 108 109 126 125 1
103 109 110 127 126 1
104 110 111 128 127 1
105 111 112 129 128 1
106 112 113 130 129 1
107 113 114 131 130 1
108 114 115 132 131 1
109 115 116 133 132 1
110 116 117 134 133 1
111 117 118 135 134 1
112 118 119 136 135 1
113 120 121 138 137 1
114 121 122 139 138 1
115 122 123 140 139 1
116 123 124 141 140 1
117 124 125 142 141 1
118 125 126 143 142 1
119 126 127 144 143 1
120 127 128 145 144 1
121 128 129 146 145 1
122 129 130 147 146 1
123 130 131 148 147 1
124 131 132 149 148 1
125 132 133 150 149 1
126 133 134 151 150 1
127 134 135 152 151 1
128 135 136 153 152 1
129 137 138 155 154 1
130 138 139 156 155 1
131 139 140 157 156 1
132 140 141 158 157 1
133 141 142 159 158 1
134 142 143 160 159 1
135 143 144 161 160 1

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 4 of 8

E147
Job No Sheet No Rev
127-269162-19001 5
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Plates Cont...
Plate Node A Node B Node C Node D Property

136 144 145 162 161 1


137 145 146 163 162 1
138 146 147 164 163 1
139 147 148 165 164 1
140 148 149 166 165 1
141 149 150 167 166 1
142 150 151 168 167 1
143 151 152 169 168 1
144 152 153 170 169 1
145 154 155 172 171 1
146 155 156 173 172 1
147 156 157 174 173 1
148 157 158 175 174 1
149 158 159 176 175 1
150 159 160 177 176 1
151 160 161 178 177 1
152 161 162 179 178 1
153 162 163 180 179 1
154 163 164 181 180 1
155 164 165 182 181 1
156 165 166 183 182 1
157 166 167 184 183 1
158 167 168 185 184 1
159 168 169 186 185 1
160 169 170 187 186 1
161 171 172 189 188 1
162 172 173 190 189 1
163 173 174 191 190 1
164 174 175 192 191 1
165 175 176 193 192 1
166 176 177 194 193 1
167 177 178 195 194 1
168 178 179 196 195 1
169 179 180 197 196 1
170 180 181 198 197 1
171 181 182 199 198 1
172 182 183 200 199 1
173 183 184 201 200 1
174 184 185 202 201 1
175 185 186 203 202 1
176 186 187 204 203 1
177 188 189 205 220 1
178 189 190 206 205 1
179 190 191 207 206 1
180 191 192 208 207 1

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 5 of 8

E148
Job No Sheet No Rev
127-269162-19001 6
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Plates Cont...
Plate Node A Node B Node C Node D Property

181 192 193 209 208 1


182 193 194 210 209 1
183 194 195 211 210 1
184 195 196 212 211 1
185 196 197 213 212 1
186 197 198 214 213 1
187 198 199 215 214 1
188 199 200 216 215 1
189 200 201 217 216 1
190 201 202 218 217 1
191 202 203 219 218 1
192 203 204 221 219 1

Supports
Node X Y Z rX rY rZ
(kip/in) (kip/in) (kip/in) (kip-ft/deg) (kip-ft/deg) (kip-ft/deg)
1 Fixed Fixed Fixed - Fixed -
2 - Fixed - - - -
3 - Fixed - - - -
4 - Fixed - - - -
5 - Fixed - - - -
6 - Fixed - - - -
7 - Fixed - - - -
8 - Fixed - - - -
9 - Fixed - - - -
10 - Fixed - - - -
11 - Fixed - - - -
12 - Fixed - - - -
13 - Fixed - - - -
14 - Fixed - - - -
15 - Fixed - - - -
16 - Fixed - - - -
17 Fixed Fixed Fixed - Fixed -
18 - Fixed - - - -
34 - Fixed - - - -
35 - Fixed - - - -
51 - Fixed - - - -
52 - Fixed - - - -
68 - Fixed - - - -
69 - Fixed - - - -
85 - Fixed - - - -
86 - Fixed - - - -
102 - Fixed - - - -

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 6 of 8

E149
Job No Sheet No Rev
127-269162-19001 7
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Supports Cont...
Node X Y Z rX rY rZ
(kip/in) (kip/in) (kip/in) (kip-ft/deg) (kip-ft/deg) (kip-ft/deg)
103 - Fixed - - - -
119 - Fixed - - - -
120 - Fixed - - - -
136 - Fixed - - - -
137 - Fixed - - - -
153 - Fixed - - - -
154 - Fixed - - - -
170 - Fixed - - - -
171 - Fixed - - - -
187 - Fixed - - - -
188 - Fixed - - - -
204 - Fixed - - - -
205 - Fixed - - - -
206 - Fixed - - - -
207 - Fixed - - - -
208 - Fixed - - - -
209 - Fixed - - - -
210 - Fixed - - - -
211 - Fixed - - - -
212 - Fixed - - - -
213 - Fixed - - - -
214 - Fixed - - - -
215 - Fixed - - - -
216 - Fixed - - - -
217 - Fixed - - - -
218 - Fixed - - - -
219 - Fixed - - - -
220 Fixed Fixed Fixed - Fixed -
221 Fixed Fixed Fixed - Fixed -

Primary Load Cases


Number Name Type

1 DL Dead
2 RLL Roof Live

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 7 of 8

E150
Job No Sheet No Rev
127-269162-19001 8
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

Combination Load Cases


Comb. Combination L/C Name Primary Primary L/C Name Factor

3 GENERATED ACI TABLE1 1 1 DL 1.40


4 GENERATED ACI TABLE1 2 1 DL 1.20
2 RLL 0.50
5 GENERATED ACI TABLE1 3 1 DL 1.20
6 GENERATED ACI TABLE1 4 1 DL 1.20
2 RLL 1.60
7 GENERATED ACI TABLE1 5 1 DL 0.90

177
161
145 178
129 162
146 179
113
130 163
97 180
114 147
81 164
98 131
65 148 181
82 115
49 132 165
66 99 182
33 116 149
50 83 166
17 100 133
34 67 150 183
1 84 117
18 51 134 167
68 101 184
2 35 118 151
52 85 168
19 102 135
36 69 152 185
3 86 119
20 53 136 169
70 103 186
4 37 120 153
54 87 170
21 104 137
38 71 154 187
5 88 121
22 55 138 171
72 105 188
6 39 122 155
56 89 172
23 106 139
40 73 156 189
7 90 123
24 57 140 173
74 107 190
8 41 124 157
58 91 174
25 108 141
42 75 158 191
9 92 125
26 59 142 175
76 109 192
10 43 126 159
60 93 176
27 110 143
44 77 160
11 94 127
28 61 144
78 111
12 45 128
62 95
29 112
46 79
13 96
30 63
47 80
14
31 64
15 48
32
16

Y
X Load 1
Z

Whole Structure - supports & plate #s

Print Time/Date: 07/05/2019 11:57 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 8 of 8

E151
Job No Sheet No Rev
127-269162-19001 1
Part
Software licensed to Tetra Tech Inc
Job Title FPH 2-way slab design Ref

By JSR Date06-May-19 Chd

Client RSLF-Artillery Brigade File 2-way roof slab.std Date/Time 07-May-2019 11:29

177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192

161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176

145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160

129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144

113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128

97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112

81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96

65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80

49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64

33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48

17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32

X
Y Z 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Load 3

Whole Structure - Plate #s (Input data was modified after picture taken)

MAX MOMENT = 2.592 k-in/in


Plate Center Stress Summary = 2.592 k-in/in X 12 in/ft = 31.104 k-in/ft
Shear Membrane Bending
Plate L/C Qx Qy Sx Sy Sxy Mx My Mxy
(psi) (psi) (psi) (psi) (psi) (kip-in/in) (kip-in/in) (kip-in/in)
Max Qx 2 3:GENERATED ACI 20.686
TABLE1 1 -7.652 0.000 0.000 0.000 -0.254 -0.223 1.378
Min Qx 15 3:GENERATED ACI-20.686
TABLE1 1 -7.652 0.000 0.000 0.000 -0.254 -0.223 -1.378
Max Qy 17 3:GENERATED ACI TABLE1
-7.621 1 20.112 0.000 0.000 0.000 -0.209 -0.288 1.356
Min Qy 161 3:GENERATED ACI TABLE1
-7.621 1 -20.112 0.000 0.000 0.000 -0.209 -0.288 -1.356
Max Sx 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Min Sx 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Max Sy 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Min Sy 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Max Sxy 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Min Sxy 1 1:DL 10.751 10.629 0.000 0.000 0.000 0.124 0.119 0.851
Max Mx 1 3:GENERATED ACI 15.051
TABLE1 1 14.881 0.000 0.000 0.000 0.173 0.166 1.192
Min Mx 88 3:GENERATED ACI TABLE1
-0.426 1 -0.969 0.000 0.000 0.000 -1.619 -2.592 0.017
Max My 1 3:GENERATED ACI 15.051
TABLE1 1 14.881 0.000 0.000 0.000 0.173 0.166 1.192
Min My 88 3:GENERATED ACI TABLE1
-0.426 1 -0.969 0.000 0.000 0.000 -1.619 -2.592 0.017
Max Mxy 18 3:GENERATED ACI TABLE1
-8.011 1 -8.044 0.000 0.000 0.000 -0.404 -0.476 1.621
Min Mxy 31 3:GENERATED ACI TABLE1
8.011 1 -8.044 0.000 0.000 0.000 -0.404 -0.476 -1.621

Print Time/Date: 07/05/2019 11:29 STAAD.Pro V8i (SELECTseries 6) 20.07.11.33 Print Run 1 of 1

E152
E153
E154
E155
E156
E157
E158
E159
E160
E161
E162
E163
E164
SECTION TABLE OF CONTENTS
Royal Saudi Land Forces Artillery Brigade
Structural Site Design

Building Design PAGE NO.

Pump Station………………………………….……..………………………………………………………… XS 1 - XS 58

Septic Tank ST-1………………………………………………….…..………………………………………… XS 59 - XS 87

Septic Tank ST-3………………………………………………….…..………………………………………… XS 88 - XS 116


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

References: AASHTO LRFD Bridge Design Specifications 4th Edition, 2007


ACI 318-14
ACI 350-06

Notes: HS20 wheel load is not applied to the structure.

General

1. AT REST EARTH PRESSURE IS ASSUMED


2. THE MONONOBE-OKABE APPROACH IS USED TO GET THE LATERAL EARTH PRESSURE CAUSED BY EARTHQUAKE
3. SANITARY COEFFICIENTS ARE INCLUDED IN DESIGN

XS1
4. CONSIDER WALL HINGED TOP AND FIXED BOTTOM
5. SEISMIC COEFFICIENTS: Ss=0.37g AND S1= 0.17g.
6. ASSUME GROUND WATER ELEVATION IS 1.5M BELOW GRADE U.N.O. DUE TO SITE SPECIFIC TESTS
7. DESIGN LOAD ON ROOF SLAB: 100 PSF LIVE LOAD
8. LIVE LOAD IMPACT WILL NOT BE INCLUDED
9. ROOF SLAB: HINGED FOUR SIDES
10. TWO FEET LIVE LOAD SURCHARGE ON THE TANK WALLS.
11. CORROSION RESISTANT CONCRETE OR CEMENT SHOULD BE USED, TYPE II CEMENT
12. BOTTOM SLAB: HINGED FOUR SIDES
13. PER ACI 350 - SECTION 7.12.2.2, MINIMUM FLEXURE REINFORCEMENT IS 13MM AND NOT MORE THAN 300MM APART.
14.THE SAFETY FACTOR FOR FLOTATION IS 1.25; ACI 350.4R-04 SECTION 3.1.2

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 1


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Geometry

GEOMETRY INFORMATION INPUT:


WALL HEIGHT, a: 16.40 ft 5000 mm
LONG WALL LENGTH, b: 18.04 ft 5500 mm h t
TOP/BOT. SLAB SPAN =SHORT WALL L, c: 11.48 ft 3500 mm
WALL THICKNESS, w: 1.48 ft 450 mm
TOP SLAB THICKNESS, t: 0.82 ft 250 mm
BOT. SLAB THICKNESS, f: 1.31 ft 400 mm
DEPTH OF FILL ABOVE ROOF SLAB, h: 0.00 ft 0 mm a
HEIGHT OF WATER ABOVE BASE, y: 12.14 ft 3700 mm
LENGTH OF FTG EXTENSION, x: 0.33 ft 100 mm w

x
f y

b (c, opp hand)

XS2
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Additional Input Parameters

GEOTECHNICAL INFORMATION:
WEIGHT OF SOIL BACKFILL (Dry), gsoil: 120.00 Lbs/CF
WEIGHT OF SOIL BACKFILL (Saturated): 135.00 Lbs/CF
ALLOWABLE BEARING CAPACITY: 2.50 ksf
PHI: FRICTION ANGLE OF BACKFILL: 36.00 DEG RAD = 0.6283
AT REST PRESSURE COEFF, Ko 0.47
ACTIVE PRESSURE COEFF, Ka: 0.31
LIVE LOAD SURCHARGE CONSIDERED: YES

WALL LOADING CONDITION TWO WALL LOADING CONDITION ONE


HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 10.83 ft HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft
HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 17.22 ft HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 17.22 ft
HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft
HEIGHT SOIL ON TOP SLAB - DRY: 0.00 ft HEIGHT SOIL ON TOP SLAB - DRY: 0.00 ft

XS3
MATERIAL PROPERTIES:
CUBIC WEIGHT CONCRETE=wconc: 150.00 Lbs/CF
COMP. STRENGTH OF CONC. = F'c: 4.00 ksi
TENSILE STRENGTH OF REBAR = Fy: 60.00 ksi
WEIGHT OF WATER = ww: 62.40 Lbs/CF

Design Strength Factors - Environmental Durability Factor


(ACI 350-06 R9.2.6)
φ , Flexure: 0.90
φ , Shear: 0.75

WALL CASE 1 WALL CASE 2 WALL CASE 3**


Environmental Durability Factor (ACI 350-06 EQ 9-8): ROOF SLAB Top Bottom Top Bottom Top Bottom BASE SLAB
FLEXURE: 1.87 1.69 0.32 1.69 1.69 n/a n/a 2.15
SHEAR: 1.30 1.17 0.22 1.17 1.17 n/a n/a 1.49

ENVIRONMENTAL EXPOSURE: NORMAL

**Note: Sd is not required for Seismic load combinations ACI 350 Section 21.2.1.8

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 3


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Dead Load

DL1, ROOF SLAB: 248.62 cf conc = 37.29 kips


DL2, WALLS: 1573.27 cf conc = 235.99 kips
DL3, BOTTOM SLAB: 428.86 cf conc = 64.33 kips
TOTAL CONCRETE QUANTITY: 83.36 cy

DL5, SOIL ON FTG EXT - WET: 256.38 cf soil = 34.61 kips


DL6, SOIL ON FTG EXT - DRY: 151.50 cf soil = 18.18 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips TOTAL SOIL QUANTITY: 15.11 cy
DL8, SOIL ON TOP SLAB - DRY: 0.00 cf soil = 0.00 kips (only above plan limits of base slab)

TOTAL DL CONC: 337.61 kips


TOTAL DL SOIL: 52.79 kips
TOTAL DL: 390.40 kips

XS4
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 4
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

DESIGN ROOF SLAB


Design Uniform Load:

DL1, ROOF SLAB: 248.62 cf conc = 37.29 kips


TOTAL UNIFORM DL: 0.12 ksf

DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips


DL8, SOIL ON TOP SLAB - DRY: 0.00 cf soil = 0.00 kips
TOTAL DL SOIL: 0.00 kips
TOTAL UNIFORM SOIL LOAD: 0.00 ksf

TOTAL DL: 0.12 ksf


TOTAL SOIL LOAD, EV: 0.00 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.22 ksf

XS5
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.32 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.31 ksf

b/c = 1.57 SAY ====> 1.75

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -51
+My 53
-Mx -51
+Mx 91
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 5


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 0.42 ksf


bw = 12.00 (per linear ft of slab)
Vuside= 1.78 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 0.60 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -4.05 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 7.23 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 0.60 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -4.05 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 4.21 k.ft/ft Inside Face Reinforcement

XS6
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 6
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Design Flexural Reinforcement in the Roof Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Roof Slab Thickness: 0.82 ft
Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) short = 7.53 in. = t - cover - 1/2db(short) d (M-) short = 7.53 in. = t - cover - 1/2db(short)
d (M+) long = 6.91 in. = t - cover - db(short) - 1/2db(long) d (M-) long = 6.91 in. = t - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 6.91 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Roof Slab

XS7
Vc = 2*f'c^.5*bw*d 10.48 kips
PHI*Vc = 7.86 kips
Vu = Cs*q*a = 1.78 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.28 in2 =0.0030bh/2 As T & S= 0.28 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 10.19 kip*ft PHI*Mn = 10.19 kip*ft
Mu+ inside face reinf= 7.23 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 4.05 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.28 in2 =0.0030bh/2 As T & S= 0.28 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 9.31 kip*ft PHI*Mn = 9.31 kip*ft
Mu+ inside face reinf= 4.21 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 4.05 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 7


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 2.68
M- (short) unfactored= -1.50
M+(long) unfactored= 1.56
M- (long) unfactored= -1.50

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 7.53 in d= 7.53 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.028 ρn= 0.028
k= 0.209 k= 0.209
j= 0.930 j= 0.930
M+ unfactored= 2.676 kips.ft M- unfactored= 1.500 kips.ft
fs= 14.787 ksi fs= 8.287 ksi

XS8
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 6.91 in d= 6.91 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.030 ρn= 0.030
k= 0.217 k= 0.217
j= 0.928 j= 0.928
M+ unfactored= 1.559 kips.ft M- unfactored= 1.500 kips.ft
fs= 9.419 ksi fs= 9.064 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 8


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

DESIGN WALLS

ww = 62.40 pcf
Wall clear height a = 16.40 ft
Wall thickness, w= 17.72 in Use at rest Soil pressure Ko
Bottom slab thickness f = 1.31 ft
qw = ww*a 1023.62 psf

XS9
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 9
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 1 - Tank is full and Water Table below the invert of the structure - Lateral Earth Pressure + 2ft LL Surcharge

ww = 62.40 pcf Soil pressure


Wall clear height a = 16.40 ft qsoil top = 159.06 psf qtop
Wall thickness, w= 17.72 in qsoil bot = 1084.26 psf
qwtop = ww*a 0.00 psf
qwbot= ww*a 1023.62 psf

qtop_unfact = 159.06 psf


qbot_unfact = 60.63 psf
qw
qtop_fact: 1.6*qsoiltop + 1.2*qwtop = 254.50 psf qbot
qbot_fact: 1.6*qsoilbot + 1.2*qwbot = 506.46 psf

Environmental Durability Factor, Sd: Flexure Shear


Sd_top = 1.69 1.17
Sd_bot = 0.32 0.22

XS10
b/a = 1.10 SAY ====> 1.25
c/a = 0.70 SAY ====> 0.75

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
c/a
-My -45 -26
+My 48 38

-Mx -45 -26


+Mx 63 27
Vside max 0.36 0.3
Vbot 0.39 0.27
Vtop 0.39 0.27

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 10


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.30 ksf


qbotfact * Sd = 0.11 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 1.22 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 1.32 klf <== Shear at top of wall is tensile force (Nu) in roof slab
Vubot = 1.32 klf <== Shear at bottom of wall is tensile force or compression force (Nu) in base slab

Tension reinforcement requirement for floor slab and roof slab:


Tubot = 1.32 klf
Tutop = 1.32 klf
phiT= 0.90

Bot slab Ast =Tu/(Fy*phiT): 0.024 in^2/ft Main Reinforcement Direction


Top slab Ast =Tu/(Fy*phiT): 0.024 in^2/ft Main Reinforcement Direction

XS11
B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)
qtopfact * Sd = 0.43 ksf
qbotfact * Sd = 0.16 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -3.59 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 5.03 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -3.59 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.83 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 11


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 2 - Tank is empty - Lateral Earth Pressure + 2ft LL Surcharge

qtop qbot
Surcharge = 112.80 psf 112.80 psf
Soil = 52.04 psf 360.83 psf _
Wet Soil = 0.00 psf 293.10 psf qtop
Water = 0.00 psf 675.59 psf 1

qtop_unfact = 164.84 psf


qbot_unfact = 1442.32 psf

qtop_fact: 1.6*qtop_unfact = 263.75 psf


qbot_fact: 1.6*qbot_unfact = 2307.71 psf
qbot
Environmental Durability Factor, Sd: Flexure Shear
Sd_top = 1.69 1.17
Sd_bot = 1.69 1.17

b/a = 1.10 SAY ====> 1.25

XS12
c/a = 0.70 SAY ====> 0.75

Input PCA Rectangular Concrete Tanks coefficients Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, Plate Analysis - Case: 10 <---- HINGED TOP, HINGED
b/a c/a HINGED SIDES b/a c/a BOTTOM, HINGED SIDES
-My -45 -26 -My -45 -26
+My 48 38 +My 48 38
-Mx -45 -26 -Mx -45 -26
+Mx 63 27 +Mx 63 27
Vside max 0.36 0.3 Vside max 0.36 0.3
Vbot 0.39 0.27 Vbot 0.39 0.27
Vtop 0.39 0.27 Vtop 0.39 0.27

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 12


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.31 ksf


qbotfact * Sd = 2.70 ksf
qtopfact - qbotfact = 2.40 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 15.97 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 17.30 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 17.30 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)


qtopfact * Sd = 0.45 ksf
qbotfact * Sd = 3.89 ksf
qtopfact - qbotfact = 3.45
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -47.16 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 66.02 k.ft/ft Inside Face Reinforcement

XS13
C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -47.16 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 50.30 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 13


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 3 - Under Seismic Loads + 2ft LL Surcharge

qltop = 112.80 psf qtop


qlbot = 112.80 psf
qetop = 680.90 psf
qebot = 680.90 psf

qtop_unfact = 793.70 psf


qbot_unfact = 793.70 psf
qbot
qtop_fact: 1.6*qltop + 1.0*qetop = 861.38 psf
qbot_fact: 1.6*qlbot + 1.0*qebot = 861.38 psf

b/a = 1.10 SAY ====> 1.25


c/a = 0.70 SAY ====> 0.75

XS14
Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
b/a c/a
-My -45 -26
+My 48 38
-Mx -45 -26
+Mx 63 27
Vside max 0.36 0.3
Vbot 0.39 0.27
Vtop 0.39 0.27

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 14


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact = 0.86 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.86 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Vuside = 5.09 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 5.51 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 5.51 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)

qtopfact = 0.86 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.86 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -10.43 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 14.60 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

XS15
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -10.43 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 11.13 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 15


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

DESIGN WALL REINFORCEMENT


2
Bar # As(bar) db Spg (in) As prov (in )
Wall - Vertical (outside) 8.00 0.79 1.000 9.00 1.05
Wall - Horiz (outside) 8.00 0.79 1.000 9.00 1.05
Wall - Vertical (inside) 8.00 0.79 1.000 9.00 1.05
Wall - Horiz (inside) 8.00 0.79 1.000 9.00 1.05

Check Shear Capacity:

DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (kips)
Vubot, total: 1.32 17.30 5.51 17.30
Vutop, total: 1.32 17.30 5.51 17.30
Vuside, total: 1.22 15.97 5.09 15.97

phiv = 0.75
Wall Thickness, w: 1.48 ft
Cover = 2.00 in.
d (M+) vert = 15.22 in. = w - cover - 1/2db(vert) d (M+) horiz = 14.22 in. = w - cover - db(vert) - 1/2db(horiz)

XS16
f'c = 4.00 ksi
bw = 12.00 (per linear ft of wall)

Check Shear in Tank Wall - top/bot Check Shear in Tank Wall - side
Vc = 2*f'c^.5*bw*d 23.10 kips Vc = 2*(1)*f'c^.5*bw*d 21.58 kips
PHI*Vc = 17.32 kips PHI*Vc = 16.18 kips
Vubot = 17.30 SHEAR CAPACITY O.K. Vubot = 15.97 SHEAR CAPACITY O.K.

Shear Friction
u: 1.000 11.6.4.3
phiv: 0.75
2
Avf (req'd)=Vu/(Fy*u*phi): 0.38 in
2
As (provided): 1.05 in OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 16


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Check Flexural Capacity:

Steel DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (k*ft) Max (kip*in)
Mu+ inside face reinf. 5.03 66.02 14.60 66.02 792.24
Vertical
Mu- outside face reinf. -3.59 -47.16 -10.43 -47.16 -565.89
Mu+ inside face reinf. 3.83 50.30 11.13 50.30 603.61
Horizontal
Mu- outside face reinf. -3.59 -47.16 -10.43 -47.16 -565.89

Design for Vertical Bending Moments (determine Vertical Steel):

Wall Thickness, w: 1.48 ft


Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) vert = 15.22 in. = w - cover - 1/2db(vert) d (M-) vert = 15.22 in. = w - cover - 1/2db(vert)
d (M+) horiz = 14.22 in. = w - cover - db(vert) - 1/2db(horiz) d (M-) horiz = 14.22 in. = w - cover - db(vert) - 1/2db(horiz)
f'c = 4.00 ksi
bw = 12.00 (per linear ft of slab)

Check Moment Capacity (Mu+ inside face reinf. ): Check Moment Capacity (Mu- outside face reinf.):

XS17
As T & S= 0.32 in2 =0.0030bh/2 As T & S= 0.32 in2 =0.0030bh/2
Asprov = 1.05 in2 Asprov>As T&S, OK As = 1.05 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 1.55 in a =As*Fy/(0.85*f'c*b): 1.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 68.46 kip*ft PHI*Mn = 68.46 kip*ft
Mu+ inside face reinf= 66.02 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 47.16 NEG MOMENT CAPACITY O.K.

Next, consider steel in horizontal direction.


Check Moment Capacity (Mu+ inside face reinf.): Check Moment Capacity (Mu- outside face reinf.):
As T & S= 0.32 in2 =0.0030bh/2 As T & S= 0.32 in2 =0.0030bh/2
Asprov = 1.05 in2 Asprov>As T&S, OK As = 1.05 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 1.55 in a =As*Fy/(0.85*f'c*b): 1.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 63.72 kip*ft PHI*Mn = 63.72 kip*ft
Mu+ inside face reinf= 50.30 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 47.16 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 17


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1 Load Case 2 Load Case 3


M+ vert unfactored= 1.75 23.01 13.46
M- vert unfactored= -1.25 -16.44 -9.61
M+ horiz unfactored= 1.34 17.53 10.25
M- horiz unfactored= -1.25 -16.44 -9.61

Crack Check (M+ inside face vertical reinf. ): Crack Check (Mu- outside face vertical reinf.):
Asprov = 1.05 in2 As = 1.05 in2
d= 15.22 in d= 15.22 in
n= 8.04 n= 8.04
ρ= 0.017 ρ= 0.017
ρn= 0.139 ρn= 0.139
k= 0.407 k= 0.407
j= 0.864 j= 0.864
M+ unfactored= 23.014 kips.ft M- unfactored= 16.438 kips.ft
fs= 19.931 ksi fs= 14.236 ksi

XS18
β= 1.2 β= 1.2
s= 9.000 in s= 9.000 in
db= 1.000 in db= 1.000 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M+ inside face horiz reinf. ): Crack Check (Mu- outside face horiz reinf.):
Asprov = 1.05 in2 As = 1.05 in2
d= 14.22 in d= 14.22 in
n= 8.04 n= 8.04
ρ= 0.019 ρ= 0.019
ρn= 0.149 ρn= 0.149
k= 0.417 k= 0.417
j= 0.861 j= 0.861
M+ unfactored= 17.534 kips.ft M- unfactored= 16.438 kips.ft
fs= 16.319 ksi fs= 15.299 ksi

β= 1.2 β= 1.2
s= 9.000 in s= 9.000 in
db= 1.000 in db= 1.000 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 18


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

BUOYANCY CHECK (FLOTATION)

This loading condition checks for flotation.

Ground water height: 12.14 ft

A.) Dead Load

TOTAL DL: 390.40 kips

XS19
B.) Bouyant Force

TOTAL BOUYANT FORCE: 208.10 kips

C). Safety Factor

Safety Factor = DL / B 1.88 > 1.25, OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 19


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

DESIGN BASE SLAB


DL1, ROOF SLAB: 207.50 cf conc = 31.12 kips
DL2, WALLS: 1430.24 cf conc = 214.54 kips

DL6, SOIL ON FTG EXT - DRY: 0.00 cf soil = 0.00 kips


DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips
DL8, SOIL ON TOP SLAB - DRY: 17.22 cf soil = 2.07 kips
DL7, SOIL ON TOP SLAB - WET: 10.83 cf soil = 1.46 kips

TOTAL DL CONC: 245.66 kips


TOTAL DL SOIL: 3.53 kips

TOTAL DL: 0.89 ksf


TOTAL SOIL LOAD, EV: 0.01 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 1.01 ksf BEARING PRESSURE OK

XS20
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 1.26 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 1.25 ksf

b/c = 1.57 SAY ====> 1.75

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -51
+My 53
-Mx -51
+Mx 91
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 20


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.89 ksf


bw = 12.00 (per linear ft of wall)
Vuside= 8.02 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 2.72 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -18.29 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 32.63 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 2.72 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -18.29 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 19.00 k.ft/ft Inside Face Reinforcement

XS21
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 21
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Design Flexural Reinforcement in the Base Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 6.00 0.44 0.750 8.00 0.66
Long Dir, Inside 6.00 0.44 0.750 8.00 0.66
Short Direction, Outside 6.00 0.44 0.750 8.00 0.66
Long Dir, Outside 6.00 0.44 0.750 8.00 0.66

phiv = 0.75
Base Slab Thickness: 1.31 ft
Cover (inside) = 3.00 in. Cover (outside) = 3.00 in.
d (M+) short = 12.37 in. = f - cover - 1/2db(short) d (M-) short = 12.37 in. = f - cover - 1/2db(short)
d (M+) long = 11.62 in. = f - cover - db(short) - 1/2db(long) d (M-) long = 11.62 in. = f - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 11.62 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Base Slab


Vc = 2*f'c^.5*bw*d 17.64 kips

XS22
PHI*Vc = 13.23 kips
Vu = Cs*q*a = 8.02 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.28 in2 =0.0030bh/2 As T & S= 0.28 in2 =0.0030bh/2
Asprov = 0.66 in2 Asprov>As T&S, OK As = 0.66 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.97 in a =As*Fy/(0.85*f'c*b): 0.97 in
phif = 0.90 phi = 0.90
PHI*Mn = 35.31 kip*ft PHI*Mn = 35.31 kip*ft
Mu+ inside face reinf= 32.63 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 18.29 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.28 in2 =0.0030bh/2 As T & S= 0.28 in2 =0.0030bh/2
Asprov = 0.66 in2 Asprov>As T&S, OK As = 0.66 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.97 in a =As*Fy/(0.85*f'c*b): 0.97 in
phif = 0.90 phi = 0.90
PHI*Mn = 33.08 kip*ft PHI*Mn = 33.08 kip*ft
Mu+ inside face reinf= 19.00 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 18.29 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 22


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 12.08
M- (short) unfactored= -6.77
M+(long) unfactored= 7.04
M- (long) unfactored= -6.77

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.66 in2 As = 0.66 in2
d= 12.37 in d= 12.37 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.036 ρn= 0.036
k= 0.234 k= 0.234
j= 0.922 j= 0.922
M+ unfactored= 12.084 kips.ft M- unfactored= 6.772 kips.ft
fs= 19.259 ksi fs= 10.794 ksi

XS23
β= 1.35 β= 1.35
s= 8.000 in s= 8.000 in
db= 0.750 in db= 0.750 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.66 in2 As = 0.66 in2
d= 11.62 in d= 11.62 in
n= 8.04 n= 8.04
ρ= 0.005 ρ= 0.005
ρn= 0.038 ρn= 0.038
k= 0.240 k= 0.240
j= 0.920 j= 0.920
M+ unfactored= 7.038 kips.ft M- unfactored= 6.772 kips.ft
fs= 11.969 ksi fs= 11.517 ksi

β= 1.35 β= 1.35
s= 8.000 in s= 8.000 in
db= 0.750 in db= 0.750 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Pump Chamber Page 23


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007
ASCE 7-10

Notes:

Seismic Design Load -- Parameters

Liquid-Containing Concrete Structure


GEOMETRY INFORMATION INPUT: OTHER PARAMETERS:
Outside length = 21.00 ft 6400 mm Concrete Weight= 0.15 kcf

XS24
Outside width = 14.44 ft 4400 mm I= 1 Table 4.1.1(a)
Inside Length L= 18.04 ft 5500 mm Ri= 3 Table 4.1.1(b)
Inside Width= 11.48 ft 3500 mm Rc= 1 Table 4.1.1(b)
design liquid depth HL= 16.40 ft 5000 mm Liquid Weight= 0.0624 kcf
Exterior Wall thickness= 1.48 ft 450 mm 9= 32.2 ft/s^2
Interior Wall Thickness= 0.00 ft 0 mm ρc= 4.66 lb-s^2/ft^4
Roof slab thickness= 0.82 ft 250 mm ρL= 1.94 lb-s^2/ft^4
Floor slab thickness= 1.31 ft 400 mm fc' = 4000 pci
# of exterior walls= 2 Ec= 3,604,997 psi
# of interior walls= 0 long. L/HL = 1.1
# of end walls= 2 2Л/λ= 0.63 Figure 9.2.4 page 47
design wall height Hw= 16.40 ft 5000 mm trans. L/HL = 0.7
Inside width transverse= 11.48 ft 3500 mm 2Л/λ= 0.63 Figure 9.2.4 page 47
Site Class: D
SS= 0.37
S1= 0.17
Fa= 1.504 ASCE 7-10 (Table 11.4-1)
Fv= 2.12 ASCE 7-10 (Table 11.4-2)

Seismic Design Load Page 1


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Seismic Design Load -- Step One and Step Two

DESIGN IS BASED ON ACI350.3-06 CHAPTER 4 - EARTHQUAKE DESIGN LOADS

Longitudinal direction: Transverse direction


Step One
Wr= 37.29 Kips
Ww= 235.99 Kips
L/HL= 1.10 L/HL= 0.70
ε= 0.83 Equation (9-44) ε= 0.89 Equation (9-44)
εWw= 195.73 Kips εWw= 211.17 Kips
We= εWw+Wr= 233.02 Kips We= εWw+Wr= 248.47 Kips

Step Two
total mass of liquid WL= 212.10 Kips
Wi/WL= 0.78 Equation (9-1) Wi/WL= 0.89 Equation (9-1)

XS25
Wi= 164.98 Kips Wi= 189.44 Kips
Wc/WL= 0.29 Equation (9-2) Wc/WL= 0.18 Equation (9-2)
Wc= 61.20 Kips Wc= 39.19 Kips

Seismic Design Load Page 2


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Seismic Design Load -- Step Three and Step Ten

Step 3 to 9 Longitudinal direction: Exterior walls Transverse direction Exterior walls

mw= 112.82 lb-s^2/ft^4 mw= 112.82 lb-s^2/ft^4


mi= 223.09 lb-s^2/ft^4 mi= 163.02 lb-s^2/ft^4
hw= 8.20 ft hw= 8.20 ft
hi/HL= 0.40 hi/HL= 0.43
hi= 6.51 ft hi= 7.13 ft
h= 7.08 ft h= 7.57 ft
k= 1177496.98 lb/ft^2 k= 964322.43 lb/ft^2
m= 335.91 lb-s^2/ft^4 Equation (9-10) m= 275.84 lb-s^2/ft^4 Equation (9-10)
Ti= 0.11 s Ti= 0.11 s
Tc= 2.68 s Equation (9-14) Tc= 2.13 s Equation (9-14)
Ts= 0.65 s Equation (9-34) Ts= 0.65 s Equation (9-34)
SDS= 0.37 Equation (9-35) SDS= 0.37 Equation (9-35)
SD1= 0.24 Equation (9-36) SD1= 0.24 Equation (9-36)

XS26
Ci= 0.37 s Equation (9-32/9-33) Ci= 0.37 s Equation (9-32/9-33)
Cc= 0.12 s Equation (9-37/9-38) Cc= 0.17 s Equation (9-37/9-38)

Step 10
CiI= 0.37 CiI= 0.37
CcI= 0.12 CcI= 0.17
Pw= 24.20 kips Equation (4-1) Pw= 26.11 kips Equation (4-1)
Pr= 4.61 kips Equation (4-2) Pr= 4.61 kips Equation (4-2)
Pi= 20.40 kips Equation (4-3) Pi= 23.43 kips Equation (4-3)
Pc= 7.61 kips Equation (4-4) Pc= 6.62 kips Equation (4-4)
V= 49.80 kips Equation (4-5) V= 54.56 kips Equation (4-5)
hc/HL= 0.69 Equation (9-5) hc/HL= 0.78 Equation (9-5)
hc= 11.31 hc= 12.85
Simplified method: Considering Uniform distribution of shear force:
Unit base shear v= 1.72 klf Unit base shear v= 1.30 klf
q= 105.15 psf q= 79.19 psf

Seismic Design Load Page 3


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

Seismic Design Load + Seismic-Induced Earth Pressure

Seismic Design Load: q= 105.15 psf

Seismic-Induced Earth Pressure: qoe= 575.75 psf

Total Seismic Lateral Load: qe= 680.90 psf

XS27
Seismic Design Load Page 4
SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007

Notes:

PARAMETERS FOR EARTHQUAKE-INDUCED EARTH PRESSURE

CALCULATION OF EARTHQUAKE-INDUCED EARTH PRESSURE:


(REF: ASSHTO 2007 - Appendix A11.1.1.1)

XS28
MONONOBE-OKABE ANALYSIS
Unit weight of soil: GAMMA = 120.00 Lbs/CF
t= 0.82 feet
h= 0.00 Feet
a= 16.40 Feet
Angle of friction of soil: PHI = 36.00 Degrees: RAD= 0.628318531
THETA = 10.48 Degrees: RAD= 0.182931766
Angle of friction soil/tank: DELTA = 17.00 Degrees: RAD= 0.296705973
Ground acceleration A= 0.37 g
Horizontal acceleration coef. kh = 0.185
Backfill slope angle: i= 0.00 Degrees: RAD= 0
Slope of soil face: BETA = 0.00 Degrees: RAD= 0

Seismic-Induced Earth Pressure Page 1


SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - PUMP CHAMBER Date: May 8, 2019

EARTHQUAKE-INDUCED EARTH PRESSURE


SEISMIC ACTIVE EARTH PRESSURE:

ψ= 2.633

Kae = 0.355 Equation (A11.1.1.1-2)

SEISMIC AT-REST EARTH PRESSURE (AASHTO Pg C-87)

Koe = 0.532

SEISMIC FORCE:

Eoe = 9444.672 lb Equation (A11.1.1.1-1)

qoe= 575.75 plf

XS29
Seismic-Induced Earth Pressure Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

References: AASHTO LRFD Bridge Design Specifications 4th Edition, 2007


ACI 318-14
ACI 350-06

Notes: HS20 wheel load is not applied to the structure.

General

1. AT REST EARTH PRESSURE IS ASSUMED


2. THE MONONOBE-OKABE APPROACH IS USED TO GET THE LATERAL EARTH PRESSURE CAUSED BY EARTHQUAKE
3. SANITARY COEFFICIENTS ARE INCLUDED IN DESIGN

XS30
4. CONSIDER WALL HINGED TOP AND FIXED BOTTOM
5. SEISMIC COEFFICIENTS: Ss=0.37g AND S1= 0.17g.
6. ASSUME GROUND WATER ELEVATION IS 1.5M BELOW GRADE U.N.O. DUE TO SITE SPECIFIC TESTS
7. DESIGN LOAD ON ROOF SLAB: 100 PSF LIVE LOAD
8. LIVE LOAD IMPACT WILL NOT BE INCLUDED
9. ROOF SLAB: HINGED FOUR SIDES
10. TWO FEET LIVE LOAD SURCHARGE ON THE TANK WALLS.
11. CORROSION RESISTANT CONCRETE OR CEMENT SHOULD BE USED, TYPE II CEMENT
12. BOTTOM SLAB: HINGED FOUR SIDES
13. PER ACI 350 - SECTION 7.12.2.2, MINIMUM FLEXURE REINFORCEMENT IS 13MM AND NOT MORE THAN 300MM APART.
14.THE SAFETY FACTOR FOR FLOTATION IS 1.25; ACI 350.4R-04 SECTION 3.1.2

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 1


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Geometry

GEOMETRY INFORMATION INPUT:


WALL HEIGHT, a: 5.74 ft 1750 mm
LONG WALL LENGTH, b: 6.56 ft 2000 mm h t
TOP/BOT. SLAB SPAN =SHORT WALL L, c: 6.56 ft 2000 mm
WALL THICKNESS, w: 1.48 ft 450 mm
TOP SLAB THICKNESS, t: 0.82 ft 250 mm
BOT. SLAB THICKNESS, f: 1.15 ft 350 mm
DEPTH OF FILL ABOVE ROOF SLAB, h: 0.00 ft 0 mm a
HEIGHT OF WATER ABOVE BASE, y: 1.31 ft 400 mm
LENGTH OF FTG EXTENSION, x: 0.33 ft 100 mm w

x
f y

b (c, opp hand)

XS31
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Additional Input Parameters

GEOTECHNICAL INFORMATION:
WEIGHT OF SOIL BACKFILL (Dry), gsoil: 120.00 Lbs/CF
WEIGHT OF SOIL BACKFILL (Saturated): 135.00 Lbs/CF
ALLOWABLE BEARING CAPACITY: 2.50 ksf
PHI: FRICTION ANGLE OF BACKFILL: 36.00 DEG RAD = 0.6283
AT REST PRESSURE COEFF, Ko 0.47
ACTIVE PRESSURE COEFF, Ka: 0.31
LIVE LOAD SURCHARGE CONSIDERED: YES

WALL LOADING CONDITION TWO WALL LOADING CONDITION ONE


HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.16 ft HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft
HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 6.56 ft HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 6.56 ft
HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft
HEIGHT SOIL ON TOP SLAB - DRY: 0.00 ft HEIGHT SOIL ON TOP SLAB - DRY: 0.00 ft

MATERIAL PROPERTIES:

XS32
CUBIC WEIGHT CONCRETE=wconc: 150.00 Lbs/CF
COMP. STRENGTH OF CONC. = F'c: 4.00 ksi
TENSILE STRENGTH OF REBAR = Fy: 60.00 ksi
WEIGHT OF WATER = ww: 62.40 Lbs/CF

Design Strength Factors - Environmental Durability Factor


(ACI 350-06 R9.2.6)
φ , Flexure: 0.90
φ , Shear: 0.75

WALL CASE 1 WALL CASE 2 WALL CASE 3**


Environmental Durability Factor (ACI 350-06 EQ 9-8): ROOF SLAB Top Bottom Top Bottom Top Bottom BASE SLAB
FLEXURE: 1.87 1.69 0.98 1.69 1.69 n/a n/a 2.10
SHEAR: 1.30 1.17 0.68 1.17 1.17 n/a n/a 1.46

ENVIRONMENTAL EXPOSURE: NORMAL

**Note: Sd is not required for Seismic load combinations ACI 350 Section 21.2.1.8

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 3


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Dead Load

DL1, ROOF SLAB: 74.25 cf conc = 11.14 kips


DL2, WALLS: 272.54 cf conc = 40.88 kips
DL3, BOTTOM SLAB: 118.78 cf conc = 17.82 kips
TOTAL CONCRETE QUANTITY: 17.24 cy

DL5, SOIL ON FTG EXT - WET: 2.12 cf soil = 0.29 kips


DL6, SOIL ON FTG EXT - DRY: 82.64 cf soil = 9.92 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips TOTAL SOIL QUANTITY: 3.14 cy
DL8, SOIL ON TOP SLAB - DRY: 0.00 cf soil = 0.00 kips (only above plan limits of base slab)

TOTAL DL CONC: 69.84 kips


TOTAL DL SOIL: 10.20 kips
TOTAL DL: 80.04 kips

XS33
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 4
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

DESIGN ROOF SLAB


Design Uniform Load:

DL1, ROOF SLAB: 74.25 cf conc = 11.14 kips


TOTAL UNIFORM DL: 0.12 ksf

DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips


DL8, SOIL ON TOP SLAB - DRY: 0.00 cf soil = 0.00 kips
TOTAL DL SOIL: 0.00 kips
TOTAL UNIFORM SOIL LOAD: 0.00 ksf

TOTAL DL: 0.12 ksf


TOTAL SOIL LOAD, EV: 0.00 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.22 ksf

XS34
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.32 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.31 ksf

b/c = 1.00 SAY ====> 1.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -37
+My 44
-Mx -37
+Mx 44
Vside max 0.34

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 5


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 0.42 ksf


bw = 12.00 (per linear ft of slab)
Vuside= 0.93 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 0.60 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -0.96 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 1.14 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 0.60 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -0.96 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 1.14 k.ft/ft Inside Face Reinforcement

XS35
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 6
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Design Flexural Reinforcement in the Roof Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Roof Slab Thickness: 0.82 ft
Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) short = 7.53 in. = t - cover - 1/2db(short) d (M-) short = 7.53 in. = t - cover - 1/2db(short)
d (M+) long = 6.91 in. = t - cover - db(short) - 1/2db(long) d (M-) long = 6.91 in. = t - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 6.91 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Roof Slab


Vc = 2*f'c^.5*bw*d 10.48 kips

XS36
PHI*Vc = 7.86 kips
Vu = Cs*q*a = 0.93 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.25 in2 =0.0030bh/2 As T & S= 0.25 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 10.19 kip*ft PHI*Mn = 10.19 kip*ft
Mu+ inside face reinf= 1.14 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.96 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.25 in2 =0.0030bh/2 As T & S= 0.25 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 9.31 kip*ft PHI*Mn = 9.31 kip*ft
Mu+ inside face reinf= 1.14 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.96 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 7


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 0.42
M- (short) unfactored= -0.36
M+(long) unfactored= 0.42
M- (long) unfactored= -0.36

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 7.53 in d= 7.53 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.028 ρn= 0.028
k= 0.209 k= 0.209
j= 0.930 j= 0.930
M+ unfactored= 0.423 kips.ft M- unfactored= 0.355 kips.ft
fs= 2.335 ksi fs= 1.963 ksi

XS37
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 6.91 in d= 6.91 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.030 ρn= 0.030
k= 0.217 k= 0.217
j= 0.928 j= 0.928
M+ unfactored= 0.423 kips.ft M- unfactored= 0.355 kips.ft
fs= 2.553 ksi fs= 2.147 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 8


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

DESIGN WALLS

ww = 62.40 pcf
Wall clear height a = 5.74 ft
Wall thickness, w= 17.72 in Use at rest Soil pressure Ko
Bottom slab thickness f = 1.15 ft
qw = ww*a 358.27 psf

XS38
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 9
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 1 - Tank is full and Water Table below the invert of the structure - Lateral Earth Pressure + 2ft LL Surcharge

ww = 62.40 pcf Soil pressure


Wall clear height a = 5.74 ft qsoil top = 159.06 psf qtop
Wall thickness, w= 17.72 in qsoil bot = 482.88 psf
qwtop = ww*a 0.00 psf
qwbot= ww*a 358.27 psf

qtop_unfact = 159.06 psf


qbot_unfact = 124.61 psf
qw
qtop_fact: 1.6*qsoiltop + 1.2*qwtop = 254.50 psf qbot
qbot_fact: 1.6*qsoilbot + 1.2*qwbot = 342.68 psf

Environmental Durability Factor, Sd: Flexure Shear


Sd_top = 1.69 1.17
Sd_bot = 0.98 0.68

XS39
b/a = 1.14 SAY ====> 1.25
c/a = 1.14 SAY ====> 1.25

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
c/a
-My -45 -45
+My 48 48

-Mx -45 -45


+Mx 63 63
Vside max 0.36 0.36
Vbot 0.39 0.39
Vtop 0.39 0.39

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 10


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.30 ksf


qbotfact * Sd = 0.23 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 0.55 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 0.60 klf <== Shear at top of wall is tensile force (Nu) in roof slab
Vubot = 0.60 klf <== Shear at bottom of wall is tensile force or compression force (Nu) in base slab

Tension reinforcement requirement for floor slab and roof slab:


Tubot = 0.60 klf
Tutop = 0.60 klf
phiT= 0.90

Bot slab Ast =Tu/(Fy*phiT): 0.011 in^2/ft Main Reinforcement Direction


Top slab Ast =Tu/(Fy*phiT): 0.011 in^2/ft Main Reinforcement Direction

XS40
B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)
qtopfact * Sd = 0.43 ksf
qbotfact * Sd = 0.34 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -0.57 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 0.80 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -0.57 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 0.61 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 11


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 2 - Tank is empty - Lateral Earth Pressure + 2ft LL Surcharge

qtop qbot
Surcharge = 112.80 psf 112.80 psf
Soil = 52.04 psf 360.83 psf _
Wet Soil = 0.00 psf 4.44 psf qtop
Water = 0.00 psf 10.24 psf 1

qtop_unfact = 164.84 psf


qbot_unfact = 488.30 psf

qtop_fact: 1.6*qtop_unfact = 263.75 psf


qbot_fact: 1.6*qbot_unfact = 781.29 psf
qbot
Environmental Durability Factor, Sd: Flexure Shear
Sd_top = 1.69 1.17
Sd_bot = 1.69 1.17

b/a = 1.14 SAY ====> 1.25

XS41
c/a = 1.14 SAY ====> 1.25

Input PCA Rectangular Concrete Tanks coefficients Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, Plate Analysis - Case: 10 <---- HINGED TOP, HINGED
b/a c/a HINGED SIDES b/a c/a BOTTOM, HINGED SIDES
-My -45 -45 -My -45 -45
+My 48 48 +My 48 48
-Mx -45 -45 -Mx -45 -45
+Mx 63 63 +Mx 63 63
Vside max 0.36 0.36 Vside max 0.36 0.36
Vbot 0.39 0.39 Vbot 0.39 0.39
Vtop 0.39 0.39 Vtop 0.39 0.39

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 12


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.31 ksf


qbotfact * Sd = 0.92 ksf
qtopfact - qbotfact = 0.61 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 1.89 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 2.05 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 2.05 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)


qtopfact * Sd = 0.45 ksf
qbotfact * Sd = 1.32 ksf
qtopfact - qbotfact = 0.87
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -1.96 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 2.74 k.ft/ft Inside Face Reinforcement

XS42
C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -1.96 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 2.09 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 13


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

WALL DESIGN: LOAD CASE 3 - Under Seismic Loads + 2ft LL Surcharge

qltop = 112.80 psf qtop


qlbot = 112.80 psf
qetop = 300.26 psf
qebot = 300.26 psf

qtop_unfact = 413.06 psf


qbot_unfact = 413.06 psf
qbot
qtop_fact: 1.6*qltop + 1.0*qetop = 480.74 psf
qbot_fact: 1.6*qlbot + 1.0*qebot = 480.74 psf

b/a = 1.14 SAY ====> 1.25


c/a = 1.14 SAY ====> 1.25

XS43
Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
b/a c/a
-My -45 -45
+My 48 48
-Mx -45 -45
+Mx 63 63
Vside max 0.36 0.36
Vbot 0.39 0.39
Vtop 0.39 0.39

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 14


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qtopfact = 0.48 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.48 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Vuside = 0.99 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 1.08 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 1.08 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)

qtopfact = 0.48 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.48 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -0.71 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 1.00 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

XS44
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -0.71 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 0.76 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 15


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

DESIGN WALL REINFORCEMENT


2
Bar # As(bar) db Spg (in) As prov (in )
Wall - Vertical (outside) 6.00 0.44 0.750 12.00 0.44
Wall - Horiz (outside) 6.00 0.44 0.750 12.00 0.44
Wall - Vertical (inside) 6.00 0.44 0.750 12.00 0.44
Wall - Horiz (inside) 6.00 0.44 0.750 12.00 0.44

Check Shear Capacity:

DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (kips)
Vubot, total: 0.60 2.05 1.08 2.05
Vutop, total: 0.60 2.05 1.08 2.05
Vuside, total: 0.55 1.89 0.99 1.89

phiv = 0.75
Wall Thickness, w: 1.48 ft
Cover = 2.00 in.
d (M+) vert = 15.34 in. = w - cover - 1/2db(vert) d (M+) horiz = 14.59 in. = w - cover - db(vert) - 1/2db(horiz)

XS45
f'c = 4.00 ksi
bw = 12.00 (per linear ft of wall)

Check Shear in Tank Wall - top/bot Check Shear in Tank Wall - side
Vc = 2*f'c^.5*bw*d 23.29 kips Vc = 2*(1)*f'c^.5*bw*d 22.15 kips
PHI*Vc = 17.47 kips PHI*Vc = 16.61 kips
Vubot = 2.05 SHEAR CAPACITY O.K. Vubot = 1.89 SHEAR CAPACITY O.K.

Shear Friction
u: 1.000 11.6.4.3
phiv: 0.75
2
Avf (req'd)=Vu/(Fy*u*phi): 0.05 in
2
As (provided): 0.44 in OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 16


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Check Flexural Capacity:

Steel DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (k*ft) Max (kip*in)
Mu+ inside face reinf. 0.80 2.74 1.00 2.74 32.86
Vertical
Mu- outside face reinf. -0.57 -1.96 -0.71 -1.96 -23.47
Mu+ inside face reinf. 0.61 2.09 0.76 2.09 25.03
Horizontal
Mu- outside face reinf. -0.57 -1.96 -0.71 -1.96 -23.47

Design for Vertical Bending Moments (determine Vertical Steel):

Wall Thickness, w: 1.48 ft


Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) vert = 15.34 in. = w - cover - 1/2db(vert) d (M-) vert = 15.34 in. = w - cover - 1/2db(vert)
d (M+) horiz = 14.59 in. = w - cover - db(vert) - 1/2db(horiz) d (M-) horiz = 14.59 in. = w - cover - db(vert) - 1/2db(horiz)
f'c = 4.00 ksi
bw = 12.00 (per linear ft of slab)

Check Moment Capacity (Mu+ inside face reinf. ): Check Moment Capacity (Mu- outside face reinf.):

XS46
As T & S= 0.32 in2 =0.0030bh/2 As T & S= 0.32 in2 =0.0030bh/2
Asprov = 0.44 in2 Asprov>As T&S, OK As = 0.44 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.65 in a =As*Fy/(0.85*f'c*b): 0.65 in
phif = 0.90 phi = 0.90
PHI*Mn = 29.74 kip*ft PHI*Mn = 29.74 kip*ft
Mu+ inside face reinf= 2.74 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 1.96 NEG MOMENT CAPACITY O.K.

Next, consider steel in horizontal direction.


Check Moment Capacity (Mu+ inside face reinf.): Check Moment Capacity (Mu- outside face reinf.):
As T & S= 0.32 in2 =0.0030bh/2 As T & S= 0.32 in2 =0.0030bh/2
Asprov = 0.44 in2 Asprov>As T&S, OK As = 0.44 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.65 in a =As*Fy/(0.85*f'c*b): 0.65 in
phif = 0.90 phi = 0.90
PHI*Mn = 28.25 kip*ft PHI*Mn = 28.25 kip*ft
Mu+ inside face reinf= 2.09 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 1.96 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 17


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1 Load Case 2 Load Case 3


M+ vert unfactored= 0.28 0.95 0.86
M- vert unfactored= -0.20 -0.68 -0.61
M+ horiz unfactored= 0.21 0.73 0.65
M- horiz unfactored= -0.20 -0.68 -0.61

Crack Check (M+ inside face vertical reinf. ): Crack Check (Mu- outside face vertical reinf.):
Asprov = 0.44 in2 As = 0.44 in2
d= 15.34 in d= 15.34 in
n= 8.04 n= 8.04
ρ= 0.007 ρ= 0.007
ρn= 0.058 ρn= 0.058
k= 0.287 k= 0.287
j= 0.904 j= 0.904
M+ unfactored= 0.954 kips.ft M- unfactored= 0.682 kips.ft
fs= 1.876 ksi fs= 1.340 ksi

XS47
β= 1.2 β= 1.2
s= 12.000 in s= 12.000 in
db= 0.750 in db= 0.750 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M+ inside face horiz reinf. ): Crack Check (Mu- outside face horiz reinf.):
Asprov = 0.44 in2 As = 0.44 in2
d= 14.59 in d= 14.59 in
n= 8.04 n= 8.04
ρ= 0.008 ρ= 0.008
ρn= 0.061 ρn= 0.061
k= 0.293 k= 0.293
j= 0.902 j= 0.902
M+ unfactored= 0.727 kips.ft M- unfactored= 0.682 kips.ft
fs= 1.506 ksi fs= 1.412 ksi

β= 1.2 β= 1.2
s= 12.000 in s= 12.000 in
db= 0.750 in db= 0.750 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 18


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

BUOYANCY CHECK (FLOTATION)

This loading condition checks for flotation.

Ground water height: 1.31 ft

A.) Dead Load

TOTAL DL: 80.04 kips

XS48
B.) Bouyant Force

TOTAL BOUYANT FORCE: 6.19 kips

C). Safety Factor

Safety Factor = DL / B 12.93 > 1.25, OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 19


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

DESIGN BASE SLAB


DL1, ROOF SLAB: 52.99 cf conc = 7.95 kips
DL2, WALLS: 222.48 cf conc = 33.37 kips

DL6, SOIL ON FTG EXT - DRY: 0.00 cf soil = 0.00 kips


DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips
DL8, SOIL ON TOP SLAB - DRY: 6.56 cf soil = 0.79 kips
DL7, SOIL ON TOP SLAB - WET: 0.16 cf soil = 0.02 kips

TOTAL DL CONC: 41.32 kips


TOTAL DL SOIL: 0.81 kips

TOTAL DL: 0.55 ksf


TOTAL SOIL LOAD, EV: 0.01 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.66 ksf BEARING PRESSURE OK

XS49
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.84 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.83 ksf

b/c = 1.00 SAY ====> 1.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -37
+My 44
-Mx -37
+Mx 44
Vside max 0.34

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 20


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.23 ksf


bw = 12.00 (per linear ft of wall)
Vuside= 2.75 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 1.77 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -2.83 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.36 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 1.77 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -2.83 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.36 k.ft/ft Inside Face Reinforcement

XS50
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 21
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Design Flexural Reinforcement in the Base Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Base Slab Thickness: 1.15 ft
Cover (inside) = 3.00 in. Cover (outside) = 3.00 in.
d (M+) short = 10.47 in. = f - cover - 1/2db(short) d (M-) short = 10.47 in. = f - cover - 1/2db(short)
d (M+) long = 9.84 in. = f - cover - db(short) - 1/2db(long) d (M-) long = 9.84 in. = f - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 9.84 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Base Slab


Vc = 2*f'c^.5*bw*d 14.94 kips

XS51
PHI*Vc = 11.20 kips
Vu = Cs*q*a = 2.75 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.25 in2 =0.0030bh/2 As T & S= 0.25 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 14.28 kip*ft PHI*Mn = 14.28 kip*ft
Mu+ inside face reinf= 3.36 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 2.83 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.25 in2 =0.0030bh/2 As T & S= 0.25 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 13.41 kip*ft PHI*Mn = 13.41 kip*ft
Mu+ inside face reinf= 3.36 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 2.83 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 22


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 1.25
M- (short) unfactored= -1.05
M+(long) unfactored= 1.25
M- (long) unfactored= -1.05

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 10.47 in d= 10.47 in
n= 8.04 n= 8.04
ρ= 0.002 ρ= 0.002
ρn= 0.020 ρn= 0.020
k= 0.180 k= 0.180
j= 0.940 j= 0.940
M+ unfactored= 1.245 kips.ft M- unfactored= 1.047 kips.ft
fs= 4.900 ksi fs= 4.121 ksi

XS52
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 9.84 in d= 9.84 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.021 ρn= 0.021
k= 0.185 k= 0.185
j= 0.938 j= 0.938
M+ unfactored= 1.245 kips.ft M- unfactored= 1.047 kips.ft
fs= 5.221 ksi fs= 4.390 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\0 - Site Structural\Pump Station\Pump Station - Valve Chamber Page 23


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007
ASCE 7-10

Notes:

Seismic Design Load -- Parameters

Liquid-Containing Concrete Structure


GEOMETRY INFORMATION INPUT: OTHER PARAMETERS:
Outside length = 9.51 ft 2900 mm Concrete Weight= 0.15 kcf

XS53
Outside width = 9.51 ft 2900 mm I= 1 Table 4.1.1(a)
Inside Length L= 6.56 ft 2000 mm Ri= 3 Table 4.1.1(b)
Inside Width= 6.56 ft 2000 mm Rc= 1 Table 4.1.1(b)
design liquid depth HL= 5.74 ft 1750 mm Liquid Weight= 0.0624 kcf
Exterior Wall thickness= 1.48 ft 450 mm 9= 32.2 ft/s^2
Interior Wall Thickness= 0.00 ft 0 mm ρc= 4.66 lb-s^2/ft^4
Roof slab thickness= 0.82 ft 250 mm ρL= 1.94 lb-s^2/ft^4
Floor slab thickness= 1.15 ft 350 mm fc' = 4000 pci
# of exterior walls= 2 Ec= 3,604,997 psi
# of interior walls= 0 long. L/HL = 1.142857143
# of end walls= 2 2Л/λ= 0.63 Figure 9.2.4 page 47
design wall height Hw= 5.74 ft 1750 mm trans. L/HL = 1.142857143
Inside width transverse= 6.56 ft 2000 mm 2Л/λ= 0.63 Figure 9.2.4 page 47
Site Class: D
SS= 0.37
S1= 0.17
Fa= 1.504 ASCE 7-10 (Table 11.4-1)
Fv= 2.12 ASCE 7-10 (Table 11.4-2)

Seismic Design Load Page 1


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Seismic Design Load -- Step One and Step Two

DESIGN IS BASED ON ACI350.3-06 CHAPTER 4 - EARTHQUAKE DESIGN LOADS

Longitudinal direction: Transverse direction


Step One
Wr= 11.14 Kips
Ww= 40.88 Kips
L/HL= 1.14 L/HL= 1.14
ε= 0.82 Equation (9-44) ε= 0.82 Equation (9-44)
εWw= 33.63 Kips εWw= 33.63 Kips
We= εWw+Wr= 44.77 Kips We= εWw+Wr= 44.77 Kips

Step Two
total mass of liquid WL= 15.43 Kips
Wi/WL= 0.77 Equation (9-1) Wi/WL= 0.77 Equation (9-1)

XS54
Wi= 11.80 Kips Wi= 11.80 Kips
Wc/WL= 0.30 Equation (9-2) Wc/WL= 0.30 Equation (9-2)
Wc= 4.62 Kips Wc= 4.62 Kips

Seismic Design Load Page 2


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Seismic Design Load -- Step Three and Step Ten

Step 3 to 9 Longitudinal direction: Exterior walls Transverse direction Exterior walls

mw= 39.49 lb-s^2/ft^4 mw= 39.49 lb-s^2/ft^4


mi= 27.93 lb-s^2/ft^4 mi= 27.93 lb-s^2/ft^4
hw= 2.87 ft hw= 2.87 ft
hi/HL= 0.39 hi/HL= 0.39
hi= 2.26 ft hi= 2.26 ft
h= 2.62 ft h= 2.62 ft
k= 23331517.39 lb/ft^2 k= 23331517.39 lb/ft^2
m= 67.42 lb-s^2/ft^4 Equation (9-10) m= 67.42 lb-s^2/ft^4 Equation (9-10)
Ti= 0.01 s Ti= 0.01 s
Tc= 1.61 s Equation (9-14) Tc= 1.61 s Equation (9-14)
Ts= 0.65 s Equation (9-34) Ts= 0.65 s Equation (9-34)
SDS= 0.37 Equation (9-35) SDS= 0.37 Equation (9-35)
SD1= 0.24 Equation (9-36) SD1= 0.24 Equation (9-36)

XS55
Ci= 0.37 s Equation (9-32/9-33) Ci= 0.37 s Equation (9-32/9-33)
Cc= 0.22 s Equation (9-37/9-38) Cc= 0.22 s Equation (9-37/9-38)

Step 10
CiI= 0.37 CiI= 0.37
CcI= 0.22 CcI= 0.22
Pw= 4.16 kips Equation (4-1) Pw= 4.16 kips Equation (4-1)
Pr= 1.38 kips Equation (4-2) Pr= 1.38 kips Equation (4-2)
Pi= 1.46 kips Equation (4-3) Pi= 1.46 kips Equation (4-3)
Pc= 1.03 kips Equation (4-4) Pc= 1.03 kips Equation (4-4)
V= 7.07 kips Equation (4-5) V= 7.07 kips Equation (4-5)
hc/HL= 0.68 Equation (9-5) hc/HL= 0.68 Equation (9-5)
hc= 3.91 hc= 3.91
Simplified method: Considering Uniform distribution of shear force:
Unit base shear v= 0.37 klf Unit base shear v= 0.37 klf
q= 64.72 psf q= 64.72 psf

Seismic Design Load Page 3


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

Seismic Design Load + Seismic-Induced Earth Pressure

Seismic Design Load: q= 64.72 psf

Seismic-Induced Earth Pressure: qoe= 235.53 psf

Total Seismic Lateral Load: qe= 300.26 psf

XS56
Seismic Design Load Page 4
SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007

Notes:

PARAMETERS FOR EARTHQUAKE-INDUCED EARTH PRESSURE

CALCULATION OF EARTHQUAKE-INDUCED EARTH PRESSURE:


(REF: ASSHTO 2007 - Appendix A11.1.1.1)

XS57
MONONOBE-OKABE ANALYSIS
Unit weight of soil: GAMMA = 120.00 Lbs/CF
t= 0.82 feet
h= 0.00 Feet
a= 5.74 Feet
Angle of friction of soil: PHI = 36.00 Degrees: RAD= 0.628318531
THETA = 10.48 Degrees: RAD= 0.182931766
Angle of friction soil/tank: DELTA = 17.00 Degrees: RAD= 0.296705973
Ground acceleration A= 0.37 g
Horizontal acceleration coef. kh = 0.185
Backfill slope angle: i= 0.00 Degrees: RAD= 0
Slope of soil face: BETA = 0.00 Degrees: RAD= 0

Seismic-Induced Earth Pressure Page 1


SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: JSR
Description: RSLF - Artillery Brigade Checked By:
Structure: PUMP STATION - VALVE CHAMBER Date: May 8, 2019

EARTHQUAKE-INDUCED EARTH PRESSURE


SEISMIC ACTIVE EARTH PRESSURE:

ψ= 2.633

Kae = 0.355 Equation (A11.1.1.1-2)

SEISMIC AT-REST EARTH PRESSURE (AASHTO Pg C-87)

Koe = 0.532

SEISMIC FORCE:

Eoe = 1352.305 lb Equation (A11.1.1.1-1)

qoe= 235.53 plf

XS58
Seismic-Induced Earth Pressure Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

References: AASHTO LRFD Bridge Design Specifications 4th Edition, 2007


ACI 318-14
ACI 350-06

Notes: HS20 wheel load is not applied to the structure.

General

1. AT REST EARTH PRESSURE IS ASSUMED


2. THE MONONOBE-OKABE APPROACH IS USED TO GET THE LATERAL EARTH PRESSURE CAUSED BY EARTHQUAKE
3. SANITARY COEFFICIENTS ARE INCLUDED IN DESIGN

XS59
4. CONSIDER WALL HINGED TOP AND FIXED BOTTOM
5. SEISMIC COEFFICIENTS: Ss=0.37g AND S1= 0.17g.
6. ASSUME GROUND WATER ELEVATION IS 1.5M BELOW GRADE U.N.O. DUE TO SITE SPECIFIC TESTS
7. DESIGN LOAD ON ROOF SLAB: 100 PSF LIVE LOAD
8. LIVE LOAD IMPACT WILL NOT BE INCLUDED
9. ROOF SLAB: HINGED FOUR SIDES
10. TWO FEET LIVE LOAD SURCHARGE ON THE TANK WALLS.
11. CORROSION RESISTANT CONCRETE OR CEMENT SHOULD BE USED, TYPE II CEMENT
12. BOTTOM SLAB: HINGED FOUR SIDES
13. PER ACI 350 - SECTION 7.12.2.2, MINIMUM FLEXURE REINFORCEMENT IS 13MM AND NOT MORE THAN 300MM APART.
14.THE SAFETY FACTOR FOR FLOTATION IS 1.25; ACI 350.4R-04 SECTION 3.1.2

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 1


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Geometry

GEOMETRY INFORMATION INPUT:


WALL HEIGHT, a: 6.56 ft 2000 mm
LONG WALL LENGTH, b: 12.30 ft 3750 mm h t
TOP/BOT. SLAB SPAN =SHORT WALL L, c: 3.28 ft 1000 mm
WALL THICKNESS, w: 0.82 ft 250 mm
TOP SLAB THICKNESS, t: 0.82 ft 250 mm
BOT. SLAB THICKNESS, f: 0.82 ft 250 mm
DEPTH OF FILL ABOVE ROOF SLAB, h: 3.28 ft 1000 mm a
HEIGHT OF WATER ABOVE BASE, y: 0.00 ft 0 mm
LENGTH OF FTG EXTENSION, x: 0.33 ft 100 mm w

x
f y

b (c, opp hand)

XS60
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Additional Input Parameters

GEOTECHNICAL INFORMATION:
WEIGHT OF SOIL BACKFILL (Dry), gsoil: 120.00 Lbs/CF
WEIGHT OF SOIL BACKFILL (Saturated): 135.00 Lbs/CF
ALLOWABLE BEARING CAPACITY: 2.50 ksf
PHI: FRICTION ANGLE OF BACKFILL: 36.00 DEG RAD = 0.6283
AT REST PRESSURE COEFF, Ko 0.47
ACTIVE PRESSURE COEFF, Ka: 0.31
LIVE LOAD SURCHARGE CONSIDERED: YES

WALL LOADING CONDITION TWO WALL LOADING CONDITION ONE


HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft
HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 10.66 ft HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 10.66 ft
HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft
HEIGHT SOIL ON TOP SLAB - DRY: 3.28 ft HEIGHT SOIL ON TOP SLAB - DRY: 3.28 ft

MATERIAL PROPERTIES:

XS61
CUBIC WEIGHT CONCRETE=wconc: 150.00 Lbs/CF
COMP. STRENGTH OF CONC. = F'c: 4.00 ksi
TENSILE STRENGTH OF REBAR = Fy: 60.00 ksi
WEIGHT OF WATER = ww: 62.40 Lbs/CF

Design Strength Factors - Environmental Durability Factor


(ACI 350-06 R9.2.6)
φ , Flexure: 0.90
φ , Shear: 0.75

WALL CASE 1 WALL CASE 2 WALL CASE 3**


Environmental Durability Factor (ACI 350-06 EQ 9-8): ROOF SLAB Top Bottom Top Bottom Top Bottom BASE SLAB
FLEXURE: 1.79 1.69 1.26 1.69 1.69 n/a n/a 2.09
SHEAR: 1.24 1.17 0.88 1.17 1.17 n/a n/a 1.45

ENVIRONMENTAL EXPOSURE: NORMAL

**Note: Sd is not required for Seismic load combinations ACI 350 Section 21.2.1.8

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 3


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Dead Load

DL1, ROOF SLAB: 56.28 cf conc = 8.44 kips


DL2, WALLS: 185.40 cf conc = 27.81 kips
DL3, BOTTOM SLAB: 66.79 cf conc = 10.02 kips
TOTAL CONCRETE QUANTITY: 11.42 cy

DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips


DL6, SOIL ON FTG EXT - DRY: 136.58 cf soil = 16.39 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips TOTAL SOIL QUANTITY: 11.60 cy
DL8, SOIL ON TOP SLAB - DRY: 176.57 cf soil = 21.19 kips (only above plan limits of base slab)

TOTAL DL CONC: 46.27 kips


TOTAL DL SOIL: 37.58 kips
TOTAL DL: 83.85 kips

XS62
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 4
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

DESIGN ROOF SLAB


Design Uniform Load:

DL1, ROOF SLAB: 56.28 cf conc = 8.44 kips


TOTAL UNIFORM DL: 0.12 ksf

DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips


DL8, SOIL ON TOP SLAB - DRY: 176.57 cf soil = 21.19 kips
TOTAL DL SOIL: 21.19 kips
TOTAL UNIFORM SOIL LOAD: 0.31 ksf

TOTAL DL: 0.12 ksf


TOTAL SOIL LOAD, EV: 0.31 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.53 ksf

XS63
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.72 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.80 ksf

b/c = 3.75 SAY ====> 4.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -54
+My 54
-Mx -54
+Mx 123
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 5


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.00 ksf


bw = 12.00 (per linear ft of slab)
Vuside= 1.21 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 1.44 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -0.83 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 1.90 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 1.44 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -0.83 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 0.83 k.ft/ft Inside Face Reinforcement

XS64
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 6
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Design Flexural Reinforcement in the Roof Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Roof Slab Thickness: 0.82 ft
Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) short = 7.53 in. = t - cover - 1/2db(short) d (M-) short = 7.53 in. = t - cover - 1/2db(short)
d (M+) long = 6.91 in. = t - cover - db(short) - 1/2db(long) d (M-) long = 6.91 in. = t - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 6.91 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Roof Slab


Vc = 2*f'c^.5*bw*d 10.48 kips

XS65
PHI*Vc = 7.86 kips
Vu = Cs*q*a = 1.21 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 10.19 kip*ft PHI*Mn = 10.19 kip*ft
Mu+ inside face reinf= 1.90 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.83 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 9.31 kip*ft PHI*Mn = 9.31 kip*ft
Mu+ inside face reinf= 0.83 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.83 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 7


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 0.70
M- (short) unfactored= -0.31
M+(long) unfactored= 0.31
M- (long) unfactored= -0.31

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 7.53 in d= 7.53 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.028 ρn= 0.028
k= 0.209 k= 0.209
j= 0.930 j= 0.930
M+ unfactored= 0.704 kips.ft M- unfactored= 0.309 kips.ft
fs= 3.891 ksi fs= 1.708 ksi

XS66
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 6.91 in d= 6.91 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.030 ρn= 0.030
k= 0.217 k= 0.217
j= 0.928 j= 0.928
M+ unfactored= 0.309 kips.ft M- unfactored= 0.309 kips.ft
fs= 1.868 ksi fs= 1.868 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 8


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

DESIGN WALLS

ww = 62.40 pcf
Wall clear height a = 6.56 ft
Wall thickness, w= 9.84 in Use at rest Soil pressure Ko
Bottom slab thickness f = 0.82 ft
qw = ww*a 409.45 psf

XS67
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 9
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

WALL DESIGN: LOAD CASE 1 - Tank is full and Water Table below the invert of the structure - Lateral Earth Pressure + 2ft LL Surcharge

ww = 62.40 pcf Soil pressure


Wall clear height a = 6.56 ft qsoil top = 344.10 psf qtop
Wall thickness, w= 9.84 in qsoil bot = 714.18 psf
qwtop = ww*a 0.00 psf
qwbot= ww*a 409.45 psf

qtop_unfact = 344.10 psf


qbot_unfact = 304.73 psf
qw
qtop_fact: 1.6*qsoiltop + 1.2*qwtop = 550.56 psf qbot
qbot_fact: 1.6*qsoilbot + 1.2*qwbot = 651.35 psf

Environmental Durability Factor, Sd: Flexure Shear


Sd_top = 1.69 1.17
Sd_bot = 1.26 0.88

XS68
b/a = 1.88 SAY ====> 2.00
c/a = 0.50 SAY ====> 0.50

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
c/a
-My -53 -13
+My 54 25

-Mx -53 -13


+Mx 100 14
Vside max 0.37 0.23
Vbot 0.46 0.18
Vtop 0.46 0.18

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 10


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.65 ksf


qbotfact * Sd = 0.57 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 1.48 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 1.84 klf <== Shear at top of wall is tensile force (Nu) in roof slab
Vubot = 1.84 klf <== Shear at bottom of wall is tensile force or compression force (Nu) in base slab

Tension reinforcement requirement for floor slab and roof slab:


Tubot = 1.84 klf
Tutop = 1.84 klf
phiT= 0.90

Bot slab Ast =Tu/(Fy*phiT): 0.034 in^2/ft Main Reinforcement Direction


Top slab Ast =Tu/(Fy*phiT): 0.034 in^2/ft Main Reinforcement Direction

XS69
B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)
qtopfact * Sd = 0.93 ksf
qbotfact * Sd = 0.82 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -2.00 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.77 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -2.00 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 2.04 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 11


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

WALL DESIGN: LOAD CASE 2 - Tank is empty - Lateral Earth Pressure + 2ft LL Surcharge

qtop qbot
Surcharge = 112.80 psf 112.80 psf
Soil = 260.21 psf 601.38 psf _
Wet Soil = 0.00 psf 0.00 psf qtop
Water = 0.00 psf 0.00 psf

qtop_unfact = 373.01 psf


qbot_unfact = 714.18 psf

qtop_fact: 1.6*qtop_unfact = 596.82 psf


qbot_fact: 1.6*qbot_unfact = 1142.68 psf
qbot
Environmental Durability Factor, Sd: Flexure Shear
Sd_top = 1.69 1.17
Sd_bot = 1.69 1.17

b/a = 1.88 SAY ====> 2.00

XS70
c/a = 0.50 SAY ====> 0.50

Input PCA Rectangular Concrete Tanks coefficients Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, Plate Analysis - Case: 10 <---- HINGED TOP, HINGED
b/a c/a HINGED SIDES b/a c/a BOTTOM, HINGED SIDES
-My -53 -13 -My -53 -13
+My 54 25 +My 54 25
-Mx -53 -13 -Mx -53 -13
+Mx 100 14 +Mx 100 14
Vside max 0.37 0.23 Vside max 0.37 0.23
Vbot 0.46 0.18 Vbot 0.46 0.18
Vtop 0.46 0.18 Vtop 0.46 0.18

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 12


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 0.70 ksf


qbotfact * Sd = 1.34 ksf
qtopfact - qbotfact = 0.64 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 3.25 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 4.04 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 4.04 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)


qtopfact * Sd = 1.01 ksf
qbotfact * Sd = 1.93 ksf
qtopfact - qbotfact = 0.92
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -4.40 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 8.30 k.ft/ft Inside Face Reinforcement

XS71
C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -4.40 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 4.48 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 13


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

WALL DESIGN: LOAD CASE 3 - Under Seismic Loads + 2ft LL Surcharge

qltop = 112.80 psf qtop


qlbot = 112.80 psf
qetop = 545.93 psf
qebot = 545.93 psf

qtop_unfact = 658.73 psf


qbot_unfact = 658.73 psf
qbot
qtop_fact: 1.6*qltop + 1.0*qetop = 726.41 psf
qbot_fact: 1.6*qlbot + 1.0*qebot = 726.41 psf

b/a = 1.88 SAY ====> 2.00


c/a = 0.50 SAY ====> 0.50

XS72
Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
b/a c/a
-My -53 -13
+My 54 25
-Mx -53 -13
+Mx 100 14
Vside max 0.37 0.23
Vbot 0.46 0.18
Vtop 0.46 0.18

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 14


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact = 0.73 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.73 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Vuside = 1.76 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 2.19 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 2.19 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)

qtopfact = 0.73 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.73 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -1.66 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.13 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

XS73
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -1.66 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 1.69 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 15


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

DESIGN WALL REINFORCEMENT


2
Bar # As(bar) db Spg (in) As prov (in )
Wall - Vertical (outside) 5.00 0.31 0.625 12.00 0.31
Wall - Horiz (outside) 5.00 0.31 0.625 12.00 0.31
Wall - Vertical (inside) 5.00 0.31 0.625 12.00 0.31
Wall - Horiz (inside) 5.00 0.31 0.625 12.00 0.31

Check Shear Capacity:

DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (kips)
Vubot, total: 1.84 4.04 2.19 4.04
Vutop, total: 1.84 4.04 2.19 4.04
Vuside, total: 1.48 3.25 1.76 3.25

phiv = 0.75
Wall Thickness, w: 0.82 ft
Cover = 2.00 in.
d (M+) vert = 7.53 in. = w - cover - 1/2db(vert) d (M+) horiz = 6.91 in. = w - cover - db(vert) - 1/2db(horiz)

XS74
f'c = 4.00 ksi
bw = 12.00 (per linear ft of wall)

Check Shear in Tank Wall - top/bot Check Shear in Tank Wall - side
Vc = 2*f'c^.5*bw*d 11.43 kips Vc = 2*(1)*f'c^.5*bw*d 10.48 kips
PHI*Vc = 8.57 kips PHI*Vc = 7.86 kips
Vubot = 4.04 SHEAR CAPACITY O.K. Vubot = 3.25 SHEAR CAPACITY O.K.

Shear Friction
u: 1.000 11.6.4.3
phiv: 0.75
2
Avf (req'd)=Vu/(Fy*u*phi): 0.09 in
2
As (provided): 0.31 in OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 16


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Check Flexural Capacity:

Steel DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (k*ft) Max (kip*in)
Mu+ inside face reinf. 3.77 8.30 3.13 8.30 99.63
Vertical
Mu- outside face reinf. -2.00 -4.40 -1.66 -4.40 -52.80
Mu+ inside face reinf. 2.04 4.48 1.69 4.48 53.80
Horizontal
Mu- outside face reinf. -2.00 -4.40 -1.66 -4.40 -52.80

Design for Vertical Bending Moments (determine Vertical Steel):

Wall Thickness, w: 0.82 ft


Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) vert = 7.53 in. = w - cover - 1/2db(vert) d (M-) vert = 7.53 in. = w - cover - 1/2db(vert)
d (M+) horiz = 6.91 in. = w - cover - db(vert) - 1/2db(horiz) d (M-) horiz = 6.91 in. = w - cover - db(vert) - 1/2db(horiz)
f'c = 4.00 ksi
bw = 12.00 (per linear ft of slab)

Check Moment Capacity (Mu+ inside face reinf. ): Check Moment Capacity (Mu- outside face reinf.):

XS75
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 10.19 kip*ft PHI*Mn = 10.19 kip*ft
Mu+ inside face reinf= 8.30 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 4.40 NEG MOMENT CAPACITY O.K.

Next, consider steel in horizontal direction.


Check Moment Capacity (Mu+ inside face reinf.): Check Moment Capacity (Mu- outside face reinf.):
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 9.31 kip*ft PHI*Mn = 9.31 kip*ft
Mu+ inside face reinf= 4.48 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 4.40 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 17


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1 Load Case 2 Load Case 3


M+ vert unfactored= 1.31 2.89 2.84
M- vert unfactored= -0.70 -1.53 -1.50
M+ horiz unfactored= 0.71 1.56 1.53
M- horiz unfactored= -0.70 -1.53 -1.50

Crack Check (M+ inside face vertical reinf. ): Crack Check (Mu- outside face vertical reinf.):
Asprov = 0.31 in2 As = 0.31 in2
d= 7.53 in d= 7.53 in
n= 8.04 n= 8.04
ρ= 0.010 ρ= 0.010
ρn= 0.083 ρn= 0.083
k= 0.332 k= 0.332
j= 0.889 j= 0.889
M+ unfactored= 2.894 kips.ft M- unfactored= 1.534 kips.ft
fs= 16.732 ksi fs= 8.868 ksi

XS76
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M+ inside face horiz reinf. ): Crack Check (Mu- outside face horiz reinf.):
Asprov = 0.31 in2 As = 0.31 in2
d= 6.91 in d= 6.91 in
n= 8.04 n= 8.04
ρ= 0.011 ρ= 0.011
ρn= 0.090 ρn= 0.090
k= 0.344 k= 0.344
j= 0.885 j= 0.885
M+ unfactored= 1.563 kips.ft M- unfactored= 1.534 kips.ft
fs= 9.896 ksi fs= 9.713 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 18


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

BUOYANCY CHECK (FLOTATION)

This loading condition checks for flotation.

Ground water height: 0.00 ft

A.) Dead Load

TOTAL DL: 83.85 kips

XS77
B.) Bouyant Force

TOTAL BOUYANT FORCE: 0.00 kips

C). Safety Factor

Safety Factor = DL / B 8384937.89 > 1.25, OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 19


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

DESIGN BASE SLAB


DL1, ROOF SLAB: 44.14 cf conc = 6.62 kips
DL2, WALLS: 167.74 cf conc = 25.16 kips

DL6, SOIL ON FTG EXT - DRY: 0.00 cf soil = 0.00 kips


DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips
DL8, SOIL ON TOP SLAB - DRY: 10.66 cf soil = 1.28 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips

TOTAL DL CONC: 31.78 kips


TOTAL DL SOIL: 1.28 kips

TOTAL DL: 0.48 ksf


TOTAL SOIL LOAD, EV: 0.02 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.60 ksf BEARING PRESSURE OK

XS78
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.78 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.77 ksf

b/c = 3.75 SAY ====> 4.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -54
+My 54
-Mx -54
+Mx 123
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 20


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.13 ksf


bw = 12.00 (per linear ft of wall)
Vuside= 1.38 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 1.63 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -0.95 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 2.16 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 1.63 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -0.95 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 0.95 k.ft/ft Inside Face Reinforcement

XS79
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 21
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Design Flexural Reinforcement in the Base Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Base Slab Thickness: 0.82 ft
Cover (inside) = 3.00 in. Cover (outside) = 3.00 in.
d (M+) short = 6.53 in. = f - cover - 1/2db(short) d (M-) short = 6.53 in. = f - cover - 1/2db(short)
d (M+) long = 5.91 in. = f - cover - db(short) - 1/2db(long) d (M-) long = 5.91 in. = f - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 5.91 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Base Slab


Vc = 2*f'c^.5*bw*d 8.96 kips

XS80
PHI*Vc = 6.72 kips
Vu = Cs*q*a = 1.38 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 8.79 kip*ft PHI*Mn = 8.79 kip*ft
Mu+ inside face reinf= 2.16 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.95 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.18 in2 =0.0030bh/2 As T & S= 0.18 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 7.92 kip*ft PHI*Mn = 7.92 kip*ft
Mu+ inside face reinf= 0.95 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 0.95 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 22


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 0.80
M- (short) unfactored= -0.35
M+(long) unfactored= 0.35
M- (long) unfactored= -0.35

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 6.53 in d= 6.53 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.032 ρn= 0.032
k= 0.222 k= 0.222
j= 0.926 j= 0.926
M+ unfactored= 0.800 kips.ft M- unfactored= 0.351 kips.ft
fs= 5.123 ksi fs= 2.249 ksi

XS81
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 5.91 in d= 5.91 in
n= 8.04 n= 8.04
ρ= 0.004 ρ= 0.004
ρn= 0.035 ρn= 0.035
k= 0.232 k= 0.232
j= 0.923 j= 0.923
M+ unfactored= 0.351 kips.ft M- unfactored= 0.351 kips.ft
fs= 2.496 ksi fs= 2.496 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\5 - Septic Tank - ST-1\Septic Tank - ST-1.xls Page 23


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007
ASCE 7-10

Notes:

Seismic Design Load -- Parameters

Liquid-Containing Concrete Structure


GEOMETRY INFORMATION INPUT: OTHER PARAMETERS:
Outside length = 13.94 ft 4250 mm Concrete Weight= 0.15 kcf

XS82
Outside width = 4.92 ft 1500 mm I= 1 Table 4.1.1(a)
Inside Length L= 12.30 ft 3750 mm Ri= 3 Table 4.1.1(b)
Inside Width= 3.28 ft 1000 mm Rc= 1 Table 4.1.1(b)
design liquid depth HL= 6.56 ft 2000 mm Liquid Weight= 0.0624 kcf
Exterior Wall thickness= 0.82 ft 250 mm 9= 32.2 ft/s^2
Interior Wall Thickness= 0.00 ft 0 mm ρc= 4.66 lb-s^2/ft^4
Roof slab thickness= 0.82 ft 250 mm ρL= 1.94 lb-s^2/ft^4
Floor slab thickness= 0.82 ft 250 mm fc' = 4000 pci
# of exterior walls= 2 Ec= 3,604,997 psi
# of interior walls= 0 long. L/HL = 1.875
# of end walls= 2 2Л/λ= 0.63 Figure 9.2.4 page 47
design wall height Hw= 6.56 ft 2000 mm trans. L/HL = 0.5
Inside width transverse= 3.28 ft 1000 mm 2Л/λ= 0.63 Figure 9.2.4 page 47
Site Class: D
S S= 0.37
S1= 0.17
Fa= 1.504 ASCE 7-10 (Table 11.4-1)
Fv= 2.12 ASCE 7-10 (Table 11.4-2)

Seismic Design Load Page 24


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Seismic Design Load -- Step One and Step Two

DESIGN IS BASED ON ACI350.3-06 CHAPTER 4 - EARTHQUAKE DESIGN LOADS

Longitudinal direction: Transverse direction


Step One
Wr= 8.44 Kips
Ww= 27.81 Kips
L/HL= 1.88 L/HL= 0.50
ε= 0.72 Equation (9-44) ε= 0.93 Equation (9-44)
εWw= 19.92 Kips εWw= 25.85 Kips
We= εWw+Wr= 28.36 Kips We= εWw+Wr= 34.29 Kips

Step Two
total mass of liquid WL= 16.53 Kips
Wi/WL= 0.57 Equation (9-1) Wi/WL= 0.94 Equation (9-1)

XS83
Wi= 9.42 Kips Wi= 15.57 Kips
Wc/WL= 0.46 Equation (9-2) Wc/WL= 0.13 Equation (9-2)
Wc= 7.64 Kips Wc= 2.18 Kips

Seismic Design Load Page 25


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Seismic Design Load -- Step Three and Step Ten

Step 3 to 9 Longitudinal direction: Exterior walls Transverse direction Exterior walls

mw= 25.07 lb-s^2/ft^4 mw= 25.07 lb-s^2/ft^4


mi= 44.57 lb-s^2/ft^4 mi= 19.65 lb-s^2/ft^4
hw= 3.28 ft hw= 3.28 ft
hi/HL= 0.38 hi/HL= 0.45
hi= 2.46 ft hi= 2.97 ft
h= 2.76 ft h= 3.15 ft
k= 3421251.10 lb/ft^2 k= 2300529.37 lb/ft^2
m= 69.64 lb-s^2/ft^4 Equation (9-10) m= 44.72 lb-s^2/ft^4 Equation (9-10)
Ti= 0.03 s Ti= 0.03 s
Tc= 2.21 s Equation (9-14) Tc= 1.14 s Equation (9-14)
Ts= 0.65 s Equation (9-34) Ts= 0.65 s Equation (9-34)
SDS= 0.37 Equation (9-35) SDS= 0.37 Equation (9-35)
SD1= 0.24 Equation (9-36) SD1= 0.24 Equation (9-36)

XS84
Ci= 0.37 s Equation (9-32/9-33) Ci= 0.37 s Equation (9-32/9-33)
Cc= 0.16 s Equation (9-37/9-38) Cc= 0.32 s Equation (9-37/9-38)

Step 10
CiI= 0.37 CiI= 0.37
CcI= 0.16 CcI= 0.32
Pw= 2.46 kips Equation (4-1) Pw= 3.20 kips Equation (4-1)
Pr= 1.04 kips Equation (4-2) Pr= 1.04 kips Equation (4-2)
Pi= 1.16 kips Equation (4-3) Pi= 1.92 kips Equation (4-3)
Pc= 1.25 kips Equation (4-4) Pc= 0.69 kips Equation (4-4)
V= 4.84 kips Equation (4-5) V= 6.20 kips Equation (4-5)
hc/HL= 0.59 Equation (9-5) hc/HL= 0.84 Equation (9-5)
hc= 3.89 hc= 5.53
Simplified method: Considering Uniform distribution of shear force:
Unit base shear v= 0.49 klf Unit base shear v= 0.22 klf
q= 74.87 psf q= 33.90 psf

Seismic Design Load Page 26


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

Seismic Design Load + Seismic-Induced Earth Pressure

Seismic Design Load: q= 74.87 psf

Seismic-Induced Earth Pressure: qoe= 471.07 psf

Total Seismic Lateral Load: qe= 545.93 psf

XS85
Seismic Design Load Page 27
SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007

Notes:

PARAMETERS FOR EARTHQUAKE-INDUCED EARTH PRESSURE

CALCULATION OF EARTHQUAKE-INDUCED EARTH PRESSURE:


(REF: ASSHTO 2007 - Appendix A11.1.1.1)

XS86
MONONOBE-OKABE ANALYSIS
Unit weight of soil: GAMMA = 120.00 Lbs/CF
t= 0.82 feet
h= 3.28 Feet
a= 6.56 Feet
Angle of friction of soil: PHI = 36.00 Degrees: RAD= 0.628318531
THETA = 10.48 Degrees: RAD= 0.182931766
Angle of friction soil/tank: DELTA = 17.00 Degrees: RAD= 0.296705973
Ground acceleration A= 0.37 g
Horizontal acceleration coef. kh = 0.185
Backfill slope angle: i= 0.00 Degrees: RAD= 0
Slope of soil face: BETA = 0.00 Degrees: RAD= 0

Seismic-Induced Earth Pressure Page 28


SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-1 Date: May 21, 2019

EARTHQUAKE-INDUCED EARTH PRESSURE


SEISMIC ACTIVE EARTH PRESSURE:

ψ= 2.633

Kae = 0.355 Equation (A11.1.1.1-2)

SEISMIC AT-REST EARTH PRESSURE (AASHTO Pg C-87)

Koe = 0.532

SEISMIC FORCE:

Eoe = 3090.983 lb Equation (A11.1.1.1-1)

qoe= 471.07 plf

XS87
Seismic-Induced Earth Pressure Page 29
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

References: AASHTO LRFD Bridge Design Specifications 4th Edition, 2007


ACI 318-14
ACI 350-06

Notes: HS20 wheel load is not applied to the structure.

General

1. AT REST EARTH PRESSURE IS ASSUMED


2. THE MONONOBE-OKABE APPROACH IS USED TO GET THE LATERAL EARTH PRESSURE CAUSED BY EARTHQUAKE
3. SANITARY COEFFICIENTS ARE INCLUDED IN DESIGN

XS88
4. CONSIDER WALL HINGED TOP AND FIXED BOTTOM
5. SEISMIC COEFFICIENTS: Ss=0.37g AND S1= 0.17g.
6. ASSUME GROUND WATER ELEVATION IS 1.5M BELOW GRADE U.N.O. DUE TO SITE SPECIFIC TESTS
7. DESIGN LOAD ON ROOF SLAB: 100 PSF LIVE LOAD
8. LIVE LOAD IMPACT WILL NOT BE INCLUDED
9. ROOF SLAB: HINGED FOUR SIDES
10. TWO FEET LIVE LOAD SURCHARGE ON THE TANK WALLS.
11. CORROSION RESISTANT CONCRETE OR CEMENT SHOULD BE USED, TYPE II CEMENT
12. BOTTOM SLAB: HINGED FOUR SIDES
13. PER ACI 350 - SECTION 7.12.2.2, MINIMUM FLEXURE REINFORCEMENT IS 13MM AND NOT MORE THAN 300MM APART.
14.THE SAFETY FACTOR FOR FLOTATION IS 1.25; ACI 350.4R-04 SECTION 3.1.2

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 1


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Geometry

GEOMETRY INFORMATION INPUT:


WALL HEIGHT, a: 6.56 ft 2000 mm
LONG WALL LENGTH, b: 19.69 ft 6000 mm h t
TOP/BOT. SLAB SPAN =SHORT WALL L, c: 6.56 ft 2000 mm
WALL THICKNESS, w: 0.98 ft 300 mm
TOP SLAB THICKNESS, t: 0.98 ft 300 mm
BOT. SLAB THICKNESS, f: 0.98 ft 300 mm
DEPTH OF FILL ABOVE ROOF SLAB, h: 6.56 ft 2000 mm a
HEIGHT OF WATER ABOVE BASE, y: 0.00 ft 0 mm
LENGTH OF FTG EXTENSION, x: 0.33 ft 100 mm w

x
f y

b (c, opp hand)

XS89
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 2
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Additional Input Parameters

GEOTECHNICAL INFORMATION:
WEIGHT OF SOIL BACKFILL (Dry), gsoil: 120.00 Lbs/CF
WEIGHT OF SOIL BACKFILL (Saturated): 135.00 Lbs/CF
ALLOWABLE BEARING CAPACITY: 2.50 ksf
PHI: FRICTION ANGLE OF BACKFILL: 36.00 DEG RAD = 0.6283
AT REST PRESSURE COEFF, Ko 0.47
ACTIVE PRESSURE COEFF, Ka: 0.31
LIVE LOAD SURCHARGE CONSIDERED: YES

WALL LOADING CONDITION TWO WALL LOADING CONDITION ONE


HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft HEIGHT SOIL ABOVE BOT SLAB EXT - WET: 0.00 ft
HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 14.11 ft HEIGHT SOIL ABOVE BOT SLAB EXT - DRY: 14.11 ft
HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft HEIGHT SOIL ON TOP SLAB - WET: 0.00 ft
HEIGHT SOIL ON TOP SLAB - DRY: 6.56 ft HEIGHT SOIL ON TOP SLAB - DRY: 6.56 ft

MATERIAL PROPERTIES:

XS90
CUBIC WEIGHT CONCRETE=wconc: 150.00 Lbs/CF
COMP. STRENGTH OF CONC. = F'c: 4.00 ksi
TENSILE STRENGTH OF REBAR = Fy: 60.00 ksi
WEIGHT OF WATER = ww: 62.40 Lbs/CF

Design Strength Factors - Environmental Durability Factor


(ACI 350-06 R9.2.6)
φ , Flexure: 0.90
φ , Shear: 0.75

WALL CASE 1 WALL CASE 2 WALL CASE 3**


Environmental Durability Factor (ACI 350-06 EQ 9-8): ROOF SLAB Top Bottom Top Bottom Top Bottom BASE SLAB
FLEXURE: 1.76 1.69 1.40 1.69 1.69 n/a n/a 2.07
SHEAR: 1.22 1.17 0.97 1.17 1.17 n/a n/a 1.44

ENVIRONMENTAL EXPOSURE: NORMAL

**Note: Sd is not required for Seismic load combinations ACI 350 Section 21.2.1.8

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 3


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Dead Load

DL1, ROOF SLAB: 181.80 cf conc = 27.27 kips


DL2, WALLS: 364.45 cf conc = 54.67 kips
DL3, BOTTOM SLAB: 201.72 cf conc = 30.26 kips
TOTAL CONCRETE QUANTITY: 27.70 cy

DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips


DL6, SOIL ON FTG EXT - DRY: 285.48 cf soil = 34.26 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips TOTAL SOIL QUANTITY: 48.48 cy
DL8, SOIL ON TOP SLAB - DRY: 1023.42 cf soil = 122.81 kips (only above plan limits of base slab)

TOTAL DL CONC: 112.19 kips


TOTAL DL SOIL: 157.07 kips
TOTAL DL: 269.26 kips

XS91
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 4
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

DESIGN ROOF SLAB


Design Uniform Load:

DL1, ROOF SLAB: 181.80 cf conc = 27.27 kips


TOTAL UNIFORM DL: 0.15 ksf

DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips


DL8, SOIL ON TOP SLAB - DRY: 1023.42 cf soil = 122.81 kips
TOTAL DL SOIL: 122.81 kips
TOTAL UNIFORM SOIL LOAD: 0.66 ksf

TOTAL DL: 0.15 ksf


TOTAL SOIL LOAD, EV: 0.66 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.91 ksf

XS92
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 1.22 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 1.40 ksf

b/c = 3.00 SAY ====> 3.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -54
+My 54
-Mx -54
+Mx 118
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 5


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.71 ksf


bw = 12.00 (per linear ft of slab)
Vuside= 4.15 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 2.46 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -5.73 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 12.52 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 2.46 ksf
bw = 12.00 (per linear ft of slab)
Negative moment Muneg = -5.73 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 5.73 k.ft/ft Inside Face Reinforcement

XS93
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 6
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Design Flexural Reinforcement in the Roof Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 10.00 0.37
Long Dir, Inside 5.00 0.31 0.625 10.00 0.37
Short Direction, Outside 5.00 0.31 0.625 10.00 0.37
Long Dir, Outside 5.00 0.31 0.625 10.00 0.37

phiv = 0.75
Roof Slab Thickness: 0.98 ft
Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) short = 9.50 in. = t - cover - 1/2db(short) d (M-) short = 9.50 in. = t - cover - 1/2db(short)
d (M+) long = 8.87 in. = t - cover - db(short) - 1/2db(long) d (M-) long = 8.87 in. = t - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 8.87 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Roof Slab


Vc = 2*f'c^.5*bw*d 13.47 kips

XS94
PHI*Vc = 10.10 kips
Vu = Cs*q*a = 4.15 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.37 in2 Asprov>As T&S, OK As = 0.37 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.55 in a =As*Fy/(0.85*f'c*b): 0.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 15.44 kip*ft PHI*Mn = 15.44 kip*ft
Mu+ inside face reinf= 12.52 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 5.73 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.37 in2 Asprov>As T&S, OK As = 0.37 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.55 in a =As*Fy/(0.85*f'c*b): 0.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 14.40 kip*ft PHI*Mn = 14.40 kip*ft
Mu+ inside face reinf= 5.73 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 5.73 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 7


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 4.64
M- (short) unfactored= -2.12
M+(long) unfactored= 2.12
M- (long) unfactored= -2.12

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.37 in2 As = 0.37 in2
d= 9.50 in d= 9.50 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.026 ρn= 0.026
k= 0.204 k= 0.204
j= 0.932 j= 0.932
M+ unfactored= 4.636 kips.ft M- unfactored= 2.122 kips.ft
fs= 16.896 ksi fs= 7.732 ksi

XS95
β= 1.35 β= 1.35
s= 10.000 in s= 10.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.37 in2 As = 0.37 in2
d= 8.87 in d= 8.87 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.028 ρn= 0.028
k= 0.211 k= 0.211
j= 0.930 j= 0.930
M+ unfactored= 2.122 kips.ft M- unfactored= 2.122 kips.ft
fs= 8.295 ksi fs= 8.295 ksi

β= 1.35 β= 1.35
s= 10.000 in s= 10.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 8


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

DESIGN WALLS

ww = 62.40 pcf
Wall clear height a = 6.56 ft
Wall thickness, w= 11.81 in Use at rest Soil pressure Ko
Bottom slab thickness f = 0.98 ft
qw = ww*a 409.45 psf

XS96
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 9
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

WALL DESIGN: LOAD CASE 1 - Tank is full and Water Table below the invert of the structure - Lateral Earth Pressure + 2ft LL Surcharge

ww = 62.40 pcf Soil pressure


Wall clear height a = 6.56 ft qsoil top = 538.39 psf qtop
Wall thickness, w= 11.81 in qsoil bot = 908.47 psf
qwtop = ww*a 0.00 psf
qwbot= ww*a 409.45 psf

qtop_unfact = 538.39 psf


qbot_unfact = 499.02 psf
qw
qtop_fact: 1.6*qsoiltop + 1.2*qwtop = 861.42 psf qbot
qbot_fact: 1.6*qsoilbot + 1.2*qwbot = 962.21 psf

Environmental Durability Factor, Sd: Flexure Shear


Sd_top = 1.69 1.17
Sd_bot = 1.40 0.97

XS97
b/a = 3.00 SAY ====> 3.00
c/a = 1.00 SAY ====> 1.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
c/a
-My -54 -37
+My 54 44

-Mx -54 -37


+Mx 118 44
Vside max 0.37 0.34
Vbot 0.49 0.34
Vtop 0.49 0.34

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 10


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 1.01 ksf


qbotfact * Sd = 0.94 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 2.36 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 3.13 klf <== Shear at top of wall is tensile force (Nu) in roof slab
Vubot = 3.13 klf <== Shear at bottom of wall is tensile force or compression force (Nu) in base slab

Tension reinforcement requirement for floor slab and roof slab:


Tubot = 3.13 klf
Tutop = 3.13 klf
phiT= 0.90

Bot slab Ast =Tu/(Fy*phiT): 0.058 in^2/ft Main Reinforcement Direction


Top slab Ast =Tu/(Fy*phiT): 0.058 in^2/ft Main Reinforcement Direction

XS98
B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)
qtopfact * Sd = 1.45 ksf
qbotfact * Sd = 1.35 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -3.26 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 7.12 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

bw = 12.00 (per linear ft of wall)


Negative moment Muneg = -3.26 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.26 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 11


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

WALL DESIGN: LOAD CASE 2 - Tank is empty - Lateral Earth Pressure + 2ft LL Surcharge

qtop qbot
Surcharge = 112.80 psf 112.80 psf
Soil = 478.79 psf 795.67 psf _
Wet Soil = 0.00 psf 0.00 psf qtop
Water = 0.00 psf 0.00 psf

qtop_unfact = 591.59 psf


qbot_unfact = 908.47 psf

qtop_fact: 1.6*qtop_unfact = 946.54 psf


qbot_fact: 1.6*qbot_unfact = 1453.55 psf
qbot
Environmental Durability Factor, Sd: Flexure Shear
Sd_top = 1.69 1.17
Sd_bot = 1.69 1.17

b/a = 3.00 SAY ====> 3.00

XS99
c/a = 1.00 SAY ====> 1.00

Input PCA Rectangular Concrete Tanks coefficients Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, Plate Analysis - Case: 10 <---- HINGED TOP, HINGED
b/a c/a HINGED SIDES b/a c/a BOTTOM, HINGED SIDES
-My -54 -37 -My -54 -37
+My 54 44 +My 54 44
-Mx -54 -37 -Mx -54 -37
+Mx 118 44 +Mx 118 44
Vside max 0.37 0.34 Vside max 0.37 0.34
Vbot 0.49 0.34 Vbot 0.49 0.34
Vtop 0.49 0.34 Vtop 0.49 0.34

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 12


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact * Sd = 1.11 ksf


qbotfact * Sd = 1.70 ksf
qtopfact - qbotfact = 0.59 ksf
bw = 12.00 (per linear ft of wall)
Vuside= 4.14 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 5.48 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 5.48 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)


qtopfact * Sd = 1.60 ksf
qbotfact * Sd = 2.45 ksf
qtopfact - qbotfact = 0.86
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -5.70 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 12.46 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

XS100
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -5.70 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 5.70 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 13


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

WALL DESIGN: LOAD CASE 3 - Under Seismic Loads + 2ft LL Surcharge

qltop = 112.80 psf qtop


qlbot = 112.80 psf
qetop = 784.70 psf
qebot = 784.70 psf

qtop_unfact = 897.50 psf


qbot_unfact = 897.50 psf
qbot
qtop_fact: 1.6*qltop + 1.0*qetop = 965.18 psf
qbot_fact: 1.6*qlbot + 1.0*qebot = 965.18 psf

b/a = 3.00 SAY ====> 3.00


c/a = 1.00 SAY ====> 1.00

XS101
Input PCA Rectangular Concrete Tanks coefficients
Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES
b/a c/a
-My -54 -37
+My 54 44
-Mx -54 -37
+Mx 118 44
Vside max 0.37 0.34
Vbot 0.49 0.34
Vtop 0.49 0.34

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 14


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qtopfact = 0.97 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.97 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Vuside = 2.34 klf <== Shear at side of wall is compression (Nu) in other side wall
Vutop = 3.10 klf <== Shear at top of wall is compressiom (Nu) in roof slab
Vubot = 3.10 klf <== Shear at bottom of wall is compressiom (Nu) in base slab

B.) FLEXURE DESIGN LOADS - Vertical Reinforcement (MAIN REINFORCEMENT)

qtopfact = 0.97 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
qbotfact = 0.97 ksf <--- No Sd for Seismic load combinations ACI 350 Section 21.2.1.8
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -2.24 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 4.90 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Horizontal Reinforcement (MAIN REINFORCEMENT)

XS102
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -2.24 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 2.24 k.ft/ft Inside Face Reinforcement

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 15


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

DESIGN WALL REINFORCEMENT


2
Bar # As(bar) db Spg (in) As prov (in )
Wall - Vertical (outside) 5.00 0.31 0.625 10.00 0.37
Wall - Horiz (outside) 5.00 0.31 0.625 10.00 0.37
Wall - Vertical (inside) 5.00 0.31 0.625 10.00 0.37
Wall - Horiz (inside) 5.00 0.31 0.625 10.00 0.37

Check Shear Capacity:

DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (kips)
Vubot, total: 3.13 5.48 3.10 5.48
Vutop, total: 3.13 5.48 3.10 5.48
Vuside, total: 2.36 4.14 2.34 4.14

phiv = 0.75
Wall Thickness, w: 0.98 ft
Cover = 2.00 in.
d (M+) vert = 9.50 in. = w - cover - 1/2db(vert) d (M+) horiz = 8.87 in. = w - cover - db(vert) - 1/2db(horiz)

XS103
f'c = 4.00 ksi
bw = 12.00 (per linear ft of wall)

Check Shear in Tank Wall - top/bot Check Shear in Tank Wall - side
Vc = 2*f'c^.5*bw*d 14.42 kips Vc = 2*(1)*f'c^.5*bw*d 13.47 kips
PHI*Vc = 10.81 kips PHI*Vc = 10.10 kips
Vubot = 5.48 SHEAR CAPACITY O.K. Vubot = 4.14 SHEAR CAPACITY O.K.

Shear Friction
u: 1.000 11.6.4.3
phiv: 0.75
2
Avf (req'd)=Vu/(Fy*u*phi): 0.12 in
2
As (provided): 0.37 in OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 16


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Check Flexural Capacity:

Steel DESIGN LOADS Load Case 1 Load Case 2 Load Case 3 Max (k*ft) Max (kip*in)
Mu+ inside face reinf. 7.12 12.46 4.90 12.46 149.54
Vertical
Mu- outside face reinf. -3.26 -5.70 -2.24 -5.70 -68.44
Mu+ inside face reinf. 3.26 5.70 2.24 5.70 68.44
Horizontal
Mu- outside face reinf. -3.26 -5.70 -2.24 -5.70 -68.44

Design for Vertical Bending Moments (determine Vertical Steel):

Wall Thickness, w: 0.98 ft


Cover (inside) = 2.00 in. Cover (outside) = 2.00 in.
d (M+) vert = 9.50 in. = w - cover - 1/2db(vert) d (M-) vert = 9.50 in. = w - cover - 1/2db(vert)
d (M+) horiz = 8.87 in. = w - cover - db(vert) - 1/2db(horiz) d (M-) horiz = 8.87 in. = w - cover - db(vert) - 1/2db(horiz)
f'c = 4.00 ksi
bw = 12.00 (per linear ft of slab)

Check Moment Capacity (Mu+ inside face reinf. ): Check Moment Capacity (Mu- outside face reinf.):

XS104
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.37 in2 Asprov>As T&S, OK As = 0.37 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.55 in a =As*Fy/(0.85*f'c*b): 0.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 15.44 kip*ft PHI*Mn = 15.44 kip*ft
Mu+ inside face reinf= 12.46 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 5.70 NEG MOMENT CAPACITY O.K.

Next, consider steel in horizontal direction.


Check Moment Capacity (Mu+ inside face reinf.): Check Moment Capacity (Mu- outside face reinf.):
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.37 in2 Asprov>As T&S, OK As = 0.37 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.55 in a =As*Fy/(0.85*f'c*b): 0.55 in
phif = 0.90 phi = 0.90
PHI*Mn = 14.40 kip*ft PHI*Mn = 14.40 kip*ft
Mu+ inside face reinf= 5.70 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 5.70 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 17


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1 Load Case 2 Load Case 3


M+ vert unfactored= 2.48 4.34 4.56
M- vert unfactored= -1.14 -1.99 -2.09
M+ horiz unfactored= 1.14 1.99 2.09
M- horiz unfactored= -1.14 -1.99 -2.09

Crack Check (M+ inside face vertical reinf. ): Crack Check (Mu- outside face vertical reinf.):
Asprov = 0.37 in2 As = 0.37 in2
d= 9.50 in d= 9.50 in
n= 8.04 n= 8.04
ρ= 0.010 ρ= 0.010
ρn= 0.079 ρn= 0.079
k= 0.326 k= 0.326
j= 0.891 j= 0.891
M+ unfactored= 4.560 kips.ft M- unfactored= 2.087 kips.ft
fs= 17.373 ksi fs= 7.950 ksi

XS105
β= 1.35 β= 1.35
s= 10.000 in s= 10.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M+ inside face horiz reinf. ): Crack Check (Mu- outside face horiz reinf.):
Asprov = 0.37 in2 As = 0.37 in2
d= 8.87 in d= 8.87 in
n= 8.04 n= 8.04
ρ= 0.010 ρ= 0.010
ρn= 0.084 ρn= 0.084
k= 0.335 k= 0.335
j= 0.888 j= 0.888
M+ unfactored= 2.087 kips.ft M- unfactored= 2.087 kips.ft
fs= 8.539 ksi fs= 8.539 ksi

β= 1.35 β= 1.35
s= 10.000 in s= 10.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 18


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

BUOYANCY CHECK (FLOTATION)

This loading condition checks for flotation.

Ground water height: 0.00 ft

A.) Dead Load

TOTAL DL: 269.26 kips

B.) Bouyant Force

XS106
TOTAL BOUYANT FORCE: 0.00 kips

C). Safety Factor

Safety Factor = DL / B 26926303.31 > 1.25, OK

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 19


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

DESIGN BASE SLAB


DL1, ROOF SLAB: 153.51 cf conc = 23.03 kips
DL2, WALLS: 339.02 cf conc = 50.85 kips

DL6, SOIL ON FTG EXT - DRY: 0.00 cf soil = 0.00 kips


DL5, SOIL ON FTG EXT - WET: 0.00 cf soil = 0.00 kips
DL8, SOIL ON TOP SLAB - DRY: 14.11 cf soil = 1.69 kips
DL7, SOIL ON TOP SLAB - WET: 0.00 cf soil = 0.00 kips

TOTAL DL CONC: 73.88 kips


TOTAL DL SOIL: 1.69 kips

TOTAL DL: 0.42 ksf


TOTAL SOIL LOAD, EV: 0.01 ksf
TOTAL UNIFORM LIVE LOAD, LL: 0.10 ksf
HYDROSTATIC, B: 0.00 ksf
qunfact =DL + LL + EV + B 0.53 ksf BEARING PRESSURE OK

XS107
qfact = 1.2*DL + 1.75*LL + 1.3*Ev +1.0*B PER AASHTO 0.69 ksf
qfact =1.2*DL + 1.6*LL + 1.6*Ev +1.2*B PER ACI 318 0.68 ksf

b/c = 3.00 SAY ====> 3.00

Input PCA Rectangular Concrete Tanks coefficients


Plate Analysis - Case: 10 <---- HINGED TOP, HINGED BOTTOM, HINGED SIDES

-My -54
+My 54
-Mx -54
+Mx 118
Vside max 0.37

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 20


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

A.) SHEAR DESIGN LOADS

qfact * Sd = 1.00 ksf


bw = 12.00 (per linear ft of wall)
Vuside= 2.42 klf <== Shear at side of wall is compression (Nu) in other side wall

B.) FLEXURE DESIGN LOADS - Short Dir. (Mx)


qfact * Sd = 1.44 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -3.34 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 7.30 k.ft/ft Inside Face Reinforcement

C.) FLEXURE DESIGN LOADS - Long Dir. (My)


qfact * Sd = 1.44 ksf
bw = 12.00 (per linear ft of wall)
Negative moment Muneg = -3.34 k.ft/ft Outside Face Reinforcement
Positive moment Mupos = 3.34 k.ft/ft Inside Face Reinforcement

XS108
P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 21
TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Design Flexural Reinforcement in the Base Slab:

2
Bar # As(bar) db Spg (in) As prov (in )
Short Direction, Inside 5.00 0.31 0.625 12.00 0.31
Long Dir, Inside 5.00 0.31 0.625 12.00 0.31
Short Direction, Outside 5.00 0.31 0.625 12.00 0.31
Long Dir, Outside 5.00 0.31 0.625 12.00 0.31

phiv = 0.75
Base Slab Thickness: 0.98 ft
Cover (inside) = 3.00 in. Cover (outside) = 3.00 in.
d (M+) short = 8.50 in. = f - cover - 1/2db(short) d (M-) short = 8.50 in. = f - cover - 1/2db(short)
d (M+) long = 7.87 in. = f - cover - db(short) - 1/2db(long) d (M-) long = 7.87 in. = f - cover - db(short) - 1/2db(long)
f'c = 4.00 ksi dmin= 7.87 in.
bw = 12.00 (per linear ft of slab)

Check Shear in Base Slab


Vc = 2*f'c^.5*bw*d 11.95 kips

XS109
PHI*Vc = 8.96 kips
Vu = Cs*q*a = 2.42 SHEAR CAPACITY O.K.

Check Moment Capacity (Mu (short)+ inside face reinf. ): Mx+ Check Moment Capacity (Mu (short)- outside face reinf.): Mx-
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 11.54 kip*ft PHI*Mn = 11.54 kip*ft
Mu+ inside face reinf= 7.30 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 3.34 NEG MOMENT CAPACITY O.K.

Check Moment Capacity (Mu (long)+ inside face reinf. ): My+ Check Moment Capacity (Mu (long)- outside face reinf.): My-
As T & S= 0.21 in2 =0.0030bh/2 As T & S= 0.21 in2 =0.0030bh/2
Asprov = 0.31 in2 Asprov>As T&S, OK As = 0.31 in2 Asprov>As T&S, OK
a =As*Fy/(0.85*f'c*b): 0.46 in a =As*Fy/(0.85*f'c*b): 0.46 in
phif = 0.90 phi = 0.90
PHI*Mn = 10.67 kip*ft PHI*Mn = 10.67 kip*ft
Mu+ inside face reinf= 3.34 POS MOMENT CAPACITY O.K. ABS Mu- ourside face= 3.34 NEG MOMENT CAPACITY O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 22


TWO LAYER REBAR RECTANGULAR CONCRETE TANK - WHEEL LOAD NOT APPLIED
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Crack Check - Check maximum spacing of bars (ACI 350 Section 10.6.4)

Unfactored Moment: Load Case 1


M+(short) unfactored= 2.70
M- (short) unfactored= -1.24
M+(long) unfactored= 1.24
M- (long) unfactored= -1.24

Crack Check (M(short)+ inside face reinf. ): M+x Crack Check (Mu(short)- outside face reinf.): M-x
Asprov = 0.31 in2 As = 0.31 in2
d= 8.50 in d= 8.50 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.024 ρn= 0.024
k= 0.198 k= 0.198
j= 0.934 j= 0.934
M+ unfactored= 2.703 kips.ft M- unfactored= 1.237 kips.ft
fs= 13.183 ksi fs= 6.033 ksi

XS110
β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

Crack Check (M(long)+ inside face reinf. ): M+y Crack Check (Mu(long)- outside face reinf.): M-y
Asprov = 0.31 in2 As = 0.31 in2
d= 7.87 in d= 7.87 in
n= 8.04 n= 8.04
ρ= 0.003 ρ= 0.003
ρn= 0.026 ρn= 0.026
k= 0.205 k= 0.205
j= 0.932 j= 0.932
M+ unfactored= 1.237 kips.ft M- unfactored= 1.237 kips.ft
fs= 6.528 ksi fs= 6.528 ksi

β= 1.35 β= 1.35
s= 12.000 in s= 12.000 in
db= 0.625 in db= 0.625 in
fs,max= 20.000 INSIDE FACE BAR SPACING O.K. fs,max= 20.000 OUTSIDE FACE BAR SPACING O.K.

P:\269162\127-269162-19001\SupportDocs\Calcs\Structural\XS - Site Structural\6 - Septic Tank - ST-3\Septic Tank - ST-3.xls Page 23


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007
ASCE 7-10

Notes:

Seismic Design Load -- Parameters

Liquid-Containing Concrete Structure


GEOMETRY INFORMATION INPUT: OTHER PARAMETERS:
Outside length = 21.65 ft 6600 mm Concrete Weight= 0.15 kcf
Outside width = 8.53 ft 2600 mm I= 1 Table 4.1.1(a)

XS111
Inside Length L= 19.69 ft 6000 mm Ri= 3 Table 4.1.1(b)
Inside Width= 6.56 ft 2000 mm Rc= 1 Table 4.1.1(b)
design liquid depth HL= 6.56 ft 2000 mm Liquid Weight= 0.0624 kcf
Exterior Wall thickness= 0.98 ft 300 mm 9= 32.2 ft/s^2
Interior Wall Thickness= 0.00 ft 0 mm ρc= 4.66 lb-s^2/ft^4
Roof slab thickness= 0.98 ft 300 mm ρL= 1.94 lb-s^2/ft^4
Floor slab thickness= 0.98 ft 300 mm fc' = 4000 pci
# of exterior walls= 2 Ec= 3,604,997 psi
# of interior walls= 0 long. L/HL = 3
# of end walls= 2 2Л/λ= 0.63 Figure 9.2.4 page 47
design wall height Hw= 6.56 ft 2000 mm trans. L/HL = 1
Inside width transverse= 6.56 ft 2000 mm 2Л/λ= 0.63 Figure 9.2.4 page 47
Site Class: D
S S= 0.37
S1= 0.17
Fa= 1.504 ASCE 7-10 (Table 11.4-1)
Fv= 2.12 ASCE 7-10 (Table 11.4-2)

Seismic Design Load Page 24


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Seismic Design Load -- Step One and Step Two

DESIGN IS BASED ON ACI350.3-06 CHAPTER 4 - EARTHQUAKE DESIGN LOADS

Longitudinal direction: Transverse direction


Step One
Wr= 27.27 Kips
Ww= 54.67 Kips
L/HL= 3.00 L/HL= 1.00
ε= 0.58 Equation (9-44) ε= 0.85 Equation (9-44)
εWw= 31.95 Kips εWw= 46.21 Kips
We= εWw+Wr= 59.22 Kips We= εWw+Wr= 73.48 Kips

Step Two
total mass of liquid WL= 52.89 Kips
Wi/WL= 0.38 Equation (9-1) Wi/WL= 0.81 Equation (9-1)
Wi= 20.13 Kips Wi= 42.71 Kips

XS112
Wc/WL= 0.62 Equation (9-2) Wc/WL= 0.26 Equation (9-2)
Wc= 32.80 Kips Wc= 13.91 Kips

Seismic Design Load Page 25


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Seismic Design Load -- Step Three and Step Ten

Step 3 to 9 Longitudinal direction: Exterior walls Transverse direction Exterior walls

mw= 30.09 lb-s^2/ft^4 mw= 30.09 lb-s^2/ft^4


mi= 47.64 lb-s^2/ft^4 mi= 33.69 lb-s^2/ft^4
hw= 3.28 ft hw= 3.28 ft
hi/HL= 0.38 hi/HL= 0.41
hi= 2.46 ft hi= 2.67 ft
h= 2.78 ft h= 2.96 ft
k= 5771426.69 lb/ft^2 k= 4791444.71 lb/ft^2
m= 77.73 lb-s^2/ft^4 Equation (9-10) m= 63.78 lb-s^2/ft^4 Equation (9-10)
Ti= 0.02 s Ti= 0.02 s
Tc= 2.80 s Equation (9-14) Tc= 1.61 s Equation (9-14)
Ts= 0.65 s Equation (9-34) Ts= 0.65 s Equation (9-34)
SDS= 0.37 Equation (9-35) SDS= 0.37 Equation (9-35)
SD1= 0.24 Equation (9-36) SD1= 0.24 Equation (9-36)

XS113
Ci= 0.37 s Equation (9-32/9-33) Ci= 0.37 s Equation (9-32/9-33)
Cc= 0.11 s Equation (9-37/9-38) Cc= 0.22 s Equation (9-37/9-38)

Step 10
CiI= 0.37 CiI= 0.37
CcI= 0.11 CcI= 0.22
Pw= 3.95 kips Equation (4-1) Pw= 5.71 kips Equation (4-1)
Pr= 3.37 kips Equation (4-2) Pr= 3.37 kips Equation (4-2)
Pi= 2.49 kips Equation (4-3) Pi= 5.28 kips Equation (4-3)
Pc= 3.74 kips Equation (4-4) Pc= 3.11 kips Equation (4-4)
V= 10.50 kips Equation (4-5) V= 14.70 kips Equation (4-5)
hc/HL= 0.54 Equation (9-5) hc/HL= 0.71 Equation (9-5)
hc= 3.55 hc= 4.65
Simplified method: Considering Uniform distribution of shear force:
Unit base shear v= 0.62 klf Unit base shear v= 0.34 klf
q= 93.81 psf q= 51.73 psf

Seismic Design Load Page 26


SEISMIC DESIGN LOAD
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

Seismic Design Load + Seismic-Induced Earth Pressure

Seismic Design Load: q= 93.81 psf

Seismic-Induced Earth Pressure: qoe= 690.90 psf

Total Seismic Lateral Load: qe= 784.70 psf

XS114
Seismic Design Load Page 27
SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

References: ACI 350-06 Code Requirements for Environmental Engineering Concrete Structures
ACI 350.3-06 Seismic Design of Liquid-Containing Concrete Structures
AASHTO LRFD Bridge Design Specifications 4th Edition, 2007

Notes:

PARAMETERS FOR EARTHQUAKE-INDUCED EARTH PRESSURE

CALCULATION OF EARTHQUAKE-INDUCED EARTH PRESSURE:


(REF: ASSHTO 2007 - Appendix A11.1.1.1)

XS115
MONONOBE-OKABE ANALYSIS
Unit weight of soil: GAMMA = 120.00 Lbs/CF
t= 0.98 feet
h= 6.56 Feet
a= 6.56 Feet
Angle of friction of soil: PHI = 36.00 Degrees: RAD= 0.628318531
THETA = 10.48 Degrees: RAD= 0.182931766
Angle of friction soil/tank: DELTA = 17.00 Degrees: RAD= 0.296705973
Ground acceleration A= 0.37 g
Horizontal acceleration coef. kh = 0.185
Backfill slope angle: i= 0.00 Degrees: RAD= 0
Slope of soil face: BETA = 0.00 Degrees: RAD= 0

Seismic-Induced Earth Pressure Page 28


SEISMIC-INDUCED EARTH PRESSURE
General Information
Project Number: 127-269162-19001 Designed By: BRO
Description: RSLF - Artillery Brigade Checked By:
Structure: SEPTIC TANK - ST-3 Date: May 21, 2019

EARTHQUAKE-INDUCED EARTH PRESSURE


SEISMIC ACTIVE EARTH PRESSURE:

ψ= 2.633

Kae = 0.355 Equation (A11.1.1.1-2)

SEISMIC AT-REST EARTH PRESSURE (AASHTO Pg C-87)

Koe = 0.532

SEISMIC FORCE:

Eoe = 4533.442 lb Equation (A11.1.1.1-1)

qoe= 690.90 plf

XS116
Seismic-Induced Earth Pressure Page 29