Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

USN Series

Portable Ultrasonic Flaw Detectors


Handle tough applications in any environment... USN Series Display
“R” Version: 5.75" x 2.65" (146mm x 67mm)
Language
Selectable English, French, Spanish, Italian,
High Resolution LCD and EL Displays
because tests are required everywhere! Flaw Detector high resolution EL with selectable brightness;
hollow and solid A-Scan
Por tuguese, German, Dutch, Danish, Finnish,
Nor wegian, Swedish, Russian
Specifications 60 Hz update rate Connectors
Pixel density 552 x 256 BNC or Lemo selectable at order
Common to All Instruments: “L” Version: 4.5" x 3.0" (114mm x 76mm)
Transreflective LCD with backlight Keypad
Standard Package International symbols
60 Hz update rate
Lightweight Ultrasonic Flaw Detector
Both displays have Screen Savers Battery Power
Batter y Charger/AC Power Supply
Pixel density 480 x 320 6 D-size alkaline or NiCad cell
Six D-Size NiCad Batteries
Gate Monitor “L” version: up to 12 hrs operation
Detachable Batter y Holder Charging Frame
Controllable over entire sweep range in 0.1mm “R” version: up to 5.5 hrs operation
Operating Manual
increments. Alarm indication by LED. Size
Recommended Accessories
Threshold controlled 10% to 90% screen 9.8"Wx5.25"Dx5.75"H(249mmx133mmx146mm)
Combination soft protective carr y case with
height. Separate second threshold and star t Weight
light shield and shoulder neck strap.
control in multi-echo measurement mode. 6lbs (2.7kg) with NiCad batteries
UltraDOC Documentation Software
9 Pin Serial PC Cable Measurement Modes 3.10lbs (1.4kg) without batteries
Serial/Parallel Printer Cable Zero to first echo, 0.001" (0.1mm) resolution
up to 10" (245mm) ; multi-echo in gate with
USN 50 L & R:
External Charger Adapter Cable Damping
Additional Batter y Charging Frame controllable second threshold; time-of-flight to
Selectable: High and Low
Additional NiCad Batteries (6) peak or flank in gate; amplitude evaluation as
Attachable Audible Alarm % FSH or above threshold to 127%; dB Amplifier Bandpass
Batter y Belt Pack reference indicates REF gain and addition or Broadband: 0.4 MHz to 10.2 MHz
Analog Output Cable subtraction; trigonometric flaw location Memory
Hard Shell Transpor t Shipping Container Memory 30 dataset memor y locations with rapid clear
Transducer Kits Dataset memor y locations store all functions, memor y flag and A-Scan preview
Range instrument parameters plus A-Scan. Recall Optional
0.2" to 200" at steel velocity (5mm to function displays stored dataset. DAC/TCG
5000mm), range selectable in fixed steps, or
continuously variable
Data Logger USN 52 L & R:
Inspection oriented and easy • Magnification window • Stores instrument control 2,500 reading sequential thickness measure- Damping
Velocity ment storage with clear, review and direct Selectable: 50, 75, 150, 1000 Ohms
to use displays measurement datasets with A-Scans in repor t feature; configurable up to 99 files.
Continuously adjustable from .0394 to .3936 Rectification
• 40 dB dynamic DAC/TCG value in large,easy to read memor y for quick and in/µsec (1000-9999 m/second); Operating Temperature RF display plus all others
enables correction for digits. repeatable calibration. 2 programmable fixed velocities 0°C to 55°C (–20°C to +70°C sur vivable)
Amplifier Bandpass
distance/amplitude var- • Gate monitors amplitude • Amplitude and time of flight Delay Outputs Selectable: Broadband 0.4 MHz to 10.2 MHz
iations due to material loss and soundpath distance for analog output enables Minus 20 µsec to 999 µsec Gate violation output on open collector, digital Low: .25 MHz to 4.9 MHz
and beam spread Cur ve both flaw and thickness recording via strip char t or Zero Offset thickness value output on serial inter face High: 2.3 MHz to 10.8 MHz
0 to 1600 µsec Dedicated Key Functions DIN: 1.7 MHz to 8.2 MHz
displayed on A-Scan. applications. digitizing device. (USN 52L/R)
Gain COPY - Activates outputs to printer, transmit DAC/TCG
(USN 52L/R) • Multi-echo or inter face-to- • Direct printing of inspection 0 to 110 dB controllable in selectable gain to data logger, output data logger repor t 40 dB Dynamic Range with 6 dB/µsec slope
• RF display mode improves first thickness measure- repor ts. steps 0.1, 0.5, 1.0, 2.0, 6.0, and 24.0 ZOOM - Expands A-Scan display area for
Memory
signal evaluation and bond ment mode, with selectable (24dB step is programmable to other values) increased screen resolution
Lightweight, advanced and MAGNIFY - Expands area within gate for
USN 52L: 100 Dataset memor y locations
inspection of dissimilar ma- flank or peak detection. reliable Test Modes
increased A-Scan resolution in selected area
USN 52R: 140 Dataset memor y locations
terials and assists crack tip • A-Scan freeze, freeze peak, Pulse echo and dual A-Scan preview function, alphanumeric
• 6 pounds (2.7 kg) total Pulser
FREEZE - Captures current screen image or
naming of datasets, director y of all datasets
detection and sizing. and zoom functions. weight with batteries. allows continuous capture of echo peaks
with memor y flag for filled datasets, rapid
Spike/excitation pulse LOCK - Locks against inadver tent change of
(USN 52L/R) • Lock key prevents ac- • Sealed case and membrane clear function, memo functions
Pulse Repetition Frequency parameter values except gain control
• Selectable rep rate cidental change of settings. keypad are splashproof, Selectable, low & high; varies w/range dB REF - Records current gain then allows Other Functions
minimizes wraparound. Documentation and recording rugged and easy to clean Rectification changes to be separately noted; amplitude Cur vature correction, movable gate in freeze
evaluation then related to reference echo mode, auto-calibration of material velocity
• Selectable damping control • On-board thickness data • Operates on AC or 6 “D” size Positive halfwave,negative halfwave,fullwave
and probe zero
amplitude
provides transducer logger stores a total of alkaline or NiCad batteries in Reject (suppression) dB STEP - Selects gain increments Outputs
matching for broader range 2,500 readings in up to 99 a detachable housing
Controllable 0 to 80% absolutely linear HOME - Returns instrument to basic menu Analog TOF & Amplitude, TTL Go/NoGo, Sync
of applications. configurable files.
Units
Optional
Inch or millimeter selectable
• Angle beam trigonometric • RS-232 bidirectional DGS, JIS evaluation
functions display sound interface for transferring Krautkramer Branson Krautkrämer GmbH & Co. Buehler Krautkramer Ltd Krautkramer France Krautkramer Italiana,
path, projection, and depth data, A-scan displays, and 50 Industrial Park Road Rober t-Bosch-Str.3 University of War wick ZAC Sans Souci una divisione della
measurements to flaw. repor ts to a printer, com- Lewistown, PA 17044 D-50354 Hür th (Ef feren) Science Park 68, Chemin des Ormeaux Krautkramer France SA
Tel: 1-717-242-0327 Postfach 1363 GB-Coventr y CV4 7HS 69 760 Limonest France 68, Chemin des Ormeaux

USNLBRPF8985K
puter, and for remote control. Fax: 1-717-242-2606 D-50330 Hür th Tel: +44-1203-690069 Tel: +33-47-217-9220 69 760 Limonest France

Printed in USA
E-Mail: infolink@krautkramer.com Tel: +49-2233-601-0 Fax: +44-1203-693032 Fax: +33-47-847-5698 Tel: +167-790-880
Our facility’s quality Fax: +49-2233-601-402 E-Mail: buehlerkrautkramer Fax: +167-780-881
system conforms to
ISO 9001. E-Mail: Hotline@Krautkramer.de @compuser ve.com
ANSI/ASQC Q91.
www.krautkramer.com
New instruments with state-of-the-art displays based User preferred features handle the toughest Excellent screen visibility in both bright and dark
on the popular, field proven USN Series! flaw inspection and test code requirements! lighting conditions!
Now, there are ultrasonic flaw The R Series features our high • Digital measurement Trigonometric Flaw Location Function provides You can choose from four models of instruments
detectors with all the features resolution EL display and resolution: .001” (.1 mm) measurement information concerning the location of a depending on your inspection requirements.
you need for inspection in bright includes the USN 50R and the • Thickness datalogger with discontinuity detected during an angle beam test. The The compact size and light weight of these digital
sunlight as well as in dark or USN 52R instruments. They offer 2500 readings function automatically calculates and displays the sound flaw detectors provide a unique combination of
poorly lighted conditions. incredibly fine screen resolution • Two measurement gates path, projected distance and depth when the instrument ease of use, versatility and por tability.
Krautkramer’s new USN-L Series for picking up the smallest • Display zoom feature is properly calibrated.
details in critical echoes. Display • Gate magnify feature Operation with standard D-cell batteries assures
por table ultrasonic flaw detectors available batter y power anywhere your inspections
can be read easily in bright, resolution is nearly as sharp as • RS-232 bidirectional por t
analog displays. • A-Scan store, freeze and print occur. Testing in Poorly
direct sunlight. New “trans-
reflective” technology actually All are lightweight, ver y por table • Multiple language selections The USN Series of por table flaw detectors is Lighted Areas
uses sunlight to make the display flaw detectors weighing only 6 More standard features in the designed to meet the requirements of in-the-field
more visible outdoors. pounds (2.7 kg) with batteries USN 50L/R: ultrasonic inspections.
The new USN-L instruments have and easily managed size of 9.8" • High and low rep rate control 40 dB Dynamic DAC/TCG improves detectability in all The L & R display versions provide a choice based
a fast 60 Hz update rate,LCD wide x 5.25" deep x 5.75" high • High and low damping control screen ranges. Addresses composite materials, coarse on your most frequent testing location and the 50
display and a fine screen (249 mm x 133 mm x 146 mm). • Broadband amplifier grained materials, shafts, welds and other applications. and 52 models provide a choice based on the
resolution of 480 x 320 pixels . Key standard features in all • Dataset memor y for 30 Meets or exceeds industr y requirements for TCG. Can be features required for the type of testing to be done.
Backlighting is used for excellent models: datasets programmed with up to 10 data points (material depths).
visibility indoors or in dark • 6 pounds (2.7 kg) total • Optional DAC function Maximum cur ve slope is
conditions. The L Series weight with batteries Even more standard features in 6 dB per microsecond.
instruments include the USN 50L • Powered by standard NiCad the USN 52L/R: (Optional on USN 50L/R)
and the USN 52L providing a or alkaline D-Cell batteries • Four step frequency control
choice of ultrasonic features to • Dataset memor y with • Four step damping control
address individual applications. memor y flag • High and low rep rate control
• Trigonometric flaw location • 40 dB dynamic DAC/TCG with
6 dB/µsec. slope Thickness Measurement and Data Recording are
• RF display mode provided. Selectable thickness modes enable you to
• Alphanumeric naming of choose the best method for your job. The sequential
datasets datalogger provides thickness recording of up to 2500
• Director y of datasets with readings in up to 99 configurable files. Evaluate the first
A-Scan preview echo in the gate or measure
• Memo function between two echoes - it doesn’t Testing in Bright, Direct Sunlight
• Dataset memor y for 100 matter if the material is painted:
datasets: USN 52L you only measure thickness of the
• Dataset memor y for 140 metal through paint.
datasets: USN 52R
• Cur vature correction
• Movable gate in freeze mode
• Auto-calibration of material RF Display Mode enhances signal evaluation and bond
velocity and zero delay inspection of dissimilar materials. Assists crack tip
• Analog outputs: TOF and detection and sizing. Provides an advantage when the shape
amplitude of the echo is impor tant for the evaluation, i.e., peak-to-peak
distance measurements, phase changes during bond tests and
measurement of crack lengths.
(USN 52L/R only)
New instruments with state-of-the-art displays based User preferred features handle the toughest Excellent screen visibility in both bright and dark
on the popular, field proven USN Series! flaw inspection and test code requirements! lighting conditions!
Now, there are ultrasonic flaw The R Series features our high • Digital measurement Trigonometric Flaw Location Function provides You can choose from four models of instruments
detectors with all the features resolution EL display and resolution: .001” (.1 mm) measurement information concerning the location of a depending on your inspection requirements.
you need for inspection in bright includes the USN 50R and the • Thickness datalogger with discontinuity detected during an angle beam test. The The compact size and light weight of these digital
sunlight as well as in dark or USN 52R instruments. They offer 2500 readings function automatically calculates and displays the sound flaw detectors provide a unique combination of
poorly lighted conditions. incredibly fine screen resolution • Two measurement gates path, projected distance and depth when the instrument ease of use, versatility and por tability.
Krautkramer’s new USN-L Series for picking up the smallest • Display zoom feature is properly calibrated.
details in critical echoes. Display • Gate magnify feature Operation with standard D-cell batteries assures
por table ultrasonic flaw detectors available batter y power anywhere your inspections
can be read easily in bright, resolution is nearly as sharp as • RS-232 bidirectional por t
analog displays. • A-Scan store, freeze and print occur. Testing in Poorly
direct sunlight. New “trans-
reflective” technology actually All are lightweight, ver y por table • Multiple language selections The USN Series of por table flaw detectors is Lighted Areas
uses sunlight to make the display flaw detectors weighing only 6 More standard features in the designed to meet the requirements of in-the-field
more visible outdoors. pounds (2.7 kg) with batteries USN 50L/R: ultrasonic inspections.
The new USN-L instruments have and easily managed size of 9.8" • High and low rep rate control 40 dB Dynamic DAC/TCG improves detectability in all The L & R display versions provide a choice based
a fast 60 Hz update rate,LCD wide x 5.25" deep x 5.75" high • High and low damping control screen ranges. Addresses composite materials, coarse on your most frequent testing location and the 50
display and a fine screen (249 mm x 133 mm x 146 mm). • Broadband amplifier grained materials, shafts, welds and other applications. and 52 models provide a choice based on the
resolution of 480 x 320 pixels . Key standard features in all • Dataset memor y for 30 Meets or exceeds industr y requirements for TCG. Can be features required for the type of testing to be done.
Backlighting is used for excellent models: datasets programmed with up to 10 data points (material depths).
visibility indoors or in dark • 6 pounds (2.7 kg) total • Optional DAC function Maximum cur ve slope is
conditions. The L Series weight with batteries Even more standard features in 6 dB per microsecond.
instruments include the USN 50L • Powered by standard NiCad the USN 52L/R: (Optional on USN 50L/R)
and the USN 52L providing a or alkaline D-Cell batteries • Four step frequency control
choice of ultrasonic features to • Dataset memor y with • Four step damping control
address individual applications. memor y flag • High and low rep rate control
• Trigonometric flaw location • 40 dB dynamic DAC/TCG with
6 dB/µsec. slope Thickness Measurement and Data Recording are
• RF display mode provided. Selectable thickness modes enable you to
• Alphanumeric naming of choose the best method for your job. The sequential
datasets datalogger provides thickness recording of up to 2500
• Director y of datasets with readings in up to 99 configurable files. Evaluate the first
A-Scan preview echo in the gate or measure
• Memo function between two echoes - it doesn’t Testing in Bright, Direct Sunlight
• Dataset memor y for 100 matter if the material is painted:
datasets: USN 52L you only measure thickness of the
• Dataset memor y for 140 metal through paint.
datasets: USN 52R
• Cur vature correction
• Movable gate in freeze mode
• Auto-calibration of material RF Display Mode enhances signal evaluation and bond
velocity and zero delay inspection of dissimilar materials. Assists crack tip
• Analog outputs: TOF and detection and sizing. Provides an advantage when the shape
amplitude of the echo is impor tant for the evaluation, i.e., peak-to-peak
distance measurements, phase changes during bond tests and
measurement of crack lengths.
(USN 52L/R only)
New instruments with state-of-the-art displays based User preferred features handle the toughest Excellent screen visibility in both bright and dark
on the popular, field proven USN Series! flaw inspection and test code requirements! lighting conditions!
Now, there are ultrasonic flaw The R Series features our high • Digital measurement Trigonometric Flaw Location Function provides You can choose from four models of instruments
detectors with all the features resolution EL display and resolution: .001” (.1 mm) measurement information concerning the location of a depending on your inspection requirements.
you need for inspection in bright includes the USN 50R and the • Thickness datalogger with discontinuity detected during an angle beam test. The The compact size and light weight of these digital
sunlight as well as in dark or USN 52R instruments. They offer 2500 readings function automatically calculates and displays the sound flaw detectors provide a unique combination of
poorly lighted conditions. incredibly fine screen resolution • Two measurement gates path, projected distance and depth when the instrument ease of use, versatility and por tability.
Krautkramer’s new USN-L Series for picking up the smallest • Display zoom feature is properly calibrated.
details in critical echoes. Display • Gate magnify feature Operation with standard D-cell batteries assures
por table ultrasonic flaw detectors available batter y power anywhere your inspections
can be read easily in bright, resolution is nearly as sharp as • RS-232 bidirectional por t
analog displays. • A-Scan store, freeze and print occur. Testing in Poorly
direct sunlight. New “trans-
reflective” technology actually All are lightweight, ver y por table • Multiple language selections The USN Series of por table flaw detectors is Lighted Areas
uses sunlight to make the display flaw detectors weighing only 6 More standard features in the designed to meet the requirements of in-the-field
more visible outdoors. pounds (2.7 kg) with batteries USN 50L/R: ultrasonic inspections.
The new USN-L instruments have and easily managed size of 9.8" • High and low rep rate control 40 dB Dynamic DAC/TCG improves detectability in all The L & R display versions provide a choice based
a fast 60 Hz update rate,LCD wide x 5.25" deep x 5.75" high • High and low damping control screen ranges. Addresses composite materials, coarse on your most frequent testing location and the 50
display and a fine screen (249 mm x 133 mm x 146 mm). • Broadband amplifier grained materials, shafts, welds and other applications. and 52 models provide a choice based on the
resolution of 480 x 320 pixels . Key standard features in all • Dataset memor y for 30 Meets or exceeds industr y requirements for TCG. Can be features required for the type of testing to be done.
Backlighting is used for excellent models: datasets programmed with up to 10 data points (material depths).
visibility indoors or in dark • 6 pounds (2.7 kg) total • Optional DAC function Maximum cur ve slope is
conditions. The L Series weight with batteries Even more standard features in 6 dB per microsecond.
instruments include the USN 50L • Powered by standard NiCad the USN 52L/R: (Optional on USN 50L/R)
and the USN 52L providing a or alkaline D-Cell batteries • Four step frequency control
choice of ultrasonic features to • Dataset memor y with • Four step damping control
address individual applications. memor y flag • High and low rep rate control
• Trigonometric flaw location • 40 dB dynamic DAC/TCG with
6 dB/µsec. slope Thickness Measurement and Data Recording are
• RF display mode provided. Selectable thickness modes enable you to
• Alphanumeric naming of choose the best method for your job. The sequential
datasets datalogger provides thickness recording of up to 2500
• Director y of datasets with readings in up to 99 configurable files. Evaluate the first
A-Scan preview echo in the gate or measure
• Memo function between two echoes - it doesn’t Testing in Bright, Direct Sunlight
• Dataset memor y for 100 matter if the material is painted:
datasets: USN 52L you only measure thickness of the
• Dataset memor y for 140 metal through paint.
datasets: USN 52R
• Cur vature correction
• Movable gate in freeze mode
• Auto-calibration of material RF Display Mode enhances signal evaluation and bond
velocity and zero delay inspection of dissimilar materials. Assists crack tip
• Analog outputs: TOF and detection and sizing. Provides an advantage when the shape
amplitude of the echo is impor tant for the evaluation, i.e., peak-to-peak
distance measurements, phase changes during bond tests and
measurement of crack lengths.
(USN 52L/R only)
USN Series
Portable Ultrasonic Flaw Detectors
Handle tough applications in any environment... USN Series Display
“R” Version: 5.75" x 2.65" (146mm x 67mm)
Language
Selectable English, French, Spanish, Italian,
High Resolution LCD and EL Displays
because tests are required everywhere! Flaw Detector high resolution EL with selectable brightness;
hollow and solid A-Scan
Por tuguese, German, Dutch, Danish, Finnish,
Nor wegian, Swedish, Russian
Specifications 60 Hz update rate Connectors
Pixel density 552 x 256 BNC or Lemo selectable at order
Common to All Instruments: “L” Version: 4.5" x 3.0" (114mm x 76mm)
Transreflective LCD with backlight Keypad
Standard Package International symbols
60 Hz update rate
Lightweight Ultrasonic Flaw Detector
Both displays have Screen Savers Battery Power
Batter y Charger/AC Power Supply
Pixel density 480 x 320 6 D-size alkaline or NiCad cell
Six D-Size NiCad Batteries
Gate Monitor “L” version: up to 12 hrs operation
Detachable Batter y Holder Charging Frame
Controllable over entire sweep range in 0.1mm “R” version: up to 5.5 hrs operation
Operating Manual
increments. Alarm indication by LED. Size
Recommended Accessories
Threshold controlled 10% to 90% screen 9.8"Wx5.25"Dx5.75"H(249mmx133mmx146mm)
Combination soft protective carr y case with
height. Separate second threshold and star t Weight
light shield and shoulder neck strap.
control in multi-echo measurement mode. 6lbs (2.7kg) with NiCad batteries
UltraDOC Documentation Software
9 Pin Serial PC Cable Measurement Modes 3.10lbs (1.4kg) without batteries
Serial/Parallel Printer Cable Zero to first echo, 0.001" (0.1mm) resolution
up to 10" (245mm) ; multi-echo in gate with
USN 50 L & R:
External Charger Adapter Cable Damping
Additional Batter y Charging Frame controllable second threshold; time-of-flight to
Selectable: High and Low
Additional NiCad Batteries (6) peak or flank in gate; amplitude evaluation as
Attachable Audible Alarm % FSH or above threshold to 127%; dB Amplifier Bandpass
Batter y Belt Pack reference indicates REF gain and addition or Broadband: 0.4 MHz to 10.2 MHz
Analog Output Cable subtraction; trigonometric flaw location Memory
Hard Shell Transpor t Shipping Container Memory 30 dataset memor y locations with rapid clear
Transducer Kits Dataset memor y locations store all functions, memor y flag and A-Scan preview
Range instrument parameters plus A-Scan. Recall Optional
0.2" to 200" at steel velocity (5mm to function displays stored dataset. DAC/TCG
5000mm), range selectable in fixed steps, or
continuously variable
Data Logger USN 52 L & R:
Inspection oriented and easy • Magnification window • Stores instrument control 2,500 reading sequential thickness measure- Damping
Velocity ment storage with clear, review and direct Selectable: 50, 75, 150, 1000 Ohms
to use displays measurement datasets with A-Scans in repor t feature; configurable up to 99 files.
Continuously adjustable from .0394 to .3936 Rectification
• 40 dB dynamic DAC/TCG value in large,easy to read memor y for quick and in/µsec (1000-9999 m/second); Operating Temperature RF display plus all others
enables correction for digits. repeatable calibration. 2 programmable fixed velocities 0°C to 55°C (–20°C to +70°C sur vivable)
Amplifier Bandpass
distance/amplitude var- • Gate monitors amplitude • Amplitude and time of flight Delay Outputs Selectable: Broadband 0.4 MHz to 10.2 MHz
iations due to material loss and soundpath distance for analog output enables Minus 20 µsec to 999 µsec Gate violation output on open collector, digital Low: .25 MHz to 4.9 MHz
and beam spread Cur ve both flaw and thickness recording via strip char t or Zero Offset thickness value output on serial inter face High: 2.3 MHz to 10.8 MHz
0 to 1600 µsec Dedicated Key Functions DIN: 1.7 MHz to 8.2 MHz
displayed on A-Scan. applications. digitizing device. (USN 52L/R)
Gain COPY - Activates outputs to printer, transmit DAC/TCG
(USN 52L/R) • Multi-echo or inter face-to- • Direct printing of inspection 0 to 110 dB controllable in selectable gain to data logger, output data logger repor t 40 dB Dynamic Range with 6 dB/µsec slope
• RF display mode improves first thickness measure- repor ts. steps 0.1, 0.5, 1.0, 2.0, 6.0, and 24.0 ZOOM - Expands A-Scan display area for
Memory
signal evaluation and bond ment mode, with selectable (24dB step is programmable to other values) increased screen resolution
Lightweight, advanced and MAGNIFY - Expands area within gate for
USN 52L: 100 Dataset memor y locations
inspection of dissimilar ma- flank or peak detection. reliable Test Modes
increased A-Scan resolution in selected area
USN 52R: 140 Dataset memor y locations
terials and assists crack tip • A-Scan freeze, freeze peak, Pulse echo and dual A-Scan preview function, alphanumeric
• 6 pounds (2.7 kg) total Pulser
FREEZE - Captures current screen image or
naming of datasets, director y of all datasets
detection and sizing. and zoom functions. weight with batteries. allows continuous capture of echo peaks
with memor y flag for filled datasets, rapid
Spike/excitation pulse LOCK - Locks against inadver tent change of
(USN 52L/R) • Lock key prevents ac- • Sealed case and membrane clear function, memo functions
Pulse Repetition Frequency parameter values except gain control
• Selectable rep rate cidental change of settings. keypad are splashproof, Selectable, low & high; varies w/range dB REF - Records current gain then allows Other Functions
minimizes wraparound. Documentation and recording rugged and easy to clean Rectification changes to be separately noted; amplitude Cur vature correction, movable gate in freeze
evaluation then related to reference echo mode, auto-calibration of material velocity
• Selectable damping control • On-board thickness data • Operates on AC or 6 “D” size Positive halfwave,negative halfwave,fullwave
and probe zero
amplitude
provides transducer logger stores a total of alkaline or NiCad batteries in Reject (suppression) dB STEP - Selects gain increments Outputs
matching for broader range 2,500 readings in up to 99 a detachable housing
Controllable 0 to 80% absolutely linear HOME - Returns instrument to basic menu Analog TOF & Amplitude, TTL Go/NoGo, Sync
of applications. configurable files.
Units
Optional
Inch or millimeter selectable
• Angle beam trigonometric • RS-232 bidirectional DGS, JIS evaluation
functions display sound interface for transferring Krautkramer Branson Krautkrämer GmbH & Co. Buehler Krautkramer Ltd Krautkramer France Krautkramer Italiana,
path, projection, and depth data, A-scan displays, and 50 Industrial Park Road Rober t-Bosch-Str.3 University of War wick ZAC Sans Souci una divisione della
measurements to flaw. repor ts to a printer, com- Lewistown, PA 17044 D-50354 Hür th (Ef feren) Science Park 68, Chemin des Ormeaux Krautkramer France SA
Tel: 1-717-242-0327 Postfach 1363 GB-Coventr y CV4 7HS 69 760 Limonest France 68, Chemin des Ormeaux

USNLBRPF8985K
puter, and for remote control. Fax: 1-717-242-2606 D-50330 Hür th Tel: +44-1203-690069 Tel: +33-47-217-9220 69 760 Limonest France

Printed in USA
E-Mail: infolink@krautkramer.com Tel: +49-2233-601-0 Fax: +44-1203-693032 Fax: +33-47-847-5698 Tel: +167-790-880
Our facility’s quality Fax: +49-2233-601-402 E-Mail: buehlerkrautkramer Fax: +167-780-881
system conforms to
ISO 9001. E-Mail: Hotline@Krautkramer.de @compuser ve.com
ANSI/ASQC Q91.
www.krautkramer.com
USN Series
Portable Ultrasonic Flaw Detectors
Handle tough applications in any environment... USN Series Display
“R” Version: 5.75" x 2.65" (146mm x 67mm)
Language
Selectable English, French, Spanish, Italian,
High Resolution LCD and EL Displays
because tests are required everywhere! Flaw Detector high resolution EL with selectable brightness;
hollow and solid A-Scan
Por tuguese, German, Dutch, Danish, Finnish,
Nor wegian, Swedish, Russian
Specifications 60 Hz update rate Connectors
Pixel density 552 x 256 BNC or Lemo selectable at order
Common to All Instruments: “L” Version: 4.5" x 3.0" (114mm x 76mm)
Transreflective LCD with backlight Keypad
Standard Package International symbols
60 Hz update rate
Lightweight Ultrasonic Flaw Detector
Both displays have Screen Savers Battery Power
Batter y Charger/AC Power Supply
Pixel density 480 x 320 6 D-size alkaline or NiCad cell
Six D-Size NiCad Batteries
Gate Monitor “L” version: up to 12 hrs operation
Detachable Batter y Holder Charging Frame
Controllable over entire sweep range in 0.1mm “R” version: up to 5.5 hrs operation
Operating Manual
increments. Alarm indication by LED. Size
Recommended Accessories
Threshold controlled 10% to 90% screen 9.8"Wx5.25"Dx5.75"H(249mmx133mmx146mm)
Combination soft protective carr y case with
height. Separate second threshold and star t Weight
light shield and shoulder neck strap.
control in multi-echo measurement mode. 6lbs (2.7kg) with NiCad batteries
UltraDOC Documentation Software
9 Pin Serial PC Cable Measurement Modes 3.10lbs (1.4kg) without batteries
Serial/Parallel Printer Cable Zero to first echo, 0.001" (0.1mm) resolution
up to 10" (245mm) ; multi-echo in gate with
USN 50 L & R:
External Charger Adapter Cable Damping
Additional Batter y Charging Frame controllable second threshold; time-of-flight to
Selectable: High and Low
Additional NiCad Batteries (6) peak or flank in gate; amplitude evaluation as
Attachable Audible Alarm % FSH or above threshold to 127%; dB Amplifier Bandpass
Batter y Belt Pack reference indicates REF gain and addition or Broadband: 0.4 MHz to 10.2 MHz
Analog Output Cable subtraction; trigonometric flaw location Memory
Hard Shell Transpor t Shipping Container Memory 30 dataset memor y locations with rapid clear
Transducer Kits Dataset memor y locations store all functions, memor y flag and A-Scan preview
Range instrument parameters plus A-Scan. Recall Optional
0.2" to 200" at steel velocity (5mm to function displays stored dataset. DAC/TCG
5000mm), range selectable in fixed steps, or
continuously variable
Data Logger USN 52 L & R:
Inspection oriented and easy • Magnification window • Stores instrument control 2,500 reading sequential thickness measure- Damping
Velocity ment storage with clear, review and direct Selectable: 50, 75, 150, 1000 Ohms
to use displays measurement datasets with A-Scans in repor t feature; configurable up to 99 files.
Continuously adjustable from .0394 to .3936 Rectification
• 40 dB dynamic DAC/TCG value in large,easy to read memor y for quick and in/µsec (1000-9999 m/second); Operating Temperature RF display plus all others
enables correction for digits. repeatable calibration. 2 programmable fixed velocities 0°C to 55°C (–20°C to +70°C sur vivable)
Amplifier Bandpass
distance/amplitude var- • Gate monitors amplitude • Amplitude and time of flight Delay Outputs Selectable: Broadband 0.4 MHz to 10.2 MHz
iations due to material loss and soundpath distance for analog output enables Minus 20 µsec to 999 µsec Gate violation output on open collector, digital Low: .25 MHz to 4.9 MHz
and beam spread Cur ve both flaw and thickness recording via strip char t or Zero Offset thickness value output on serial inter face High: 2.3 MHz to 10.8 MHz
0 to 1600 µsec Dedicated Key Functions DIN: 1.7 MHz to 8.2 MHz
displayed on A-Scan. applications. digitizing device. (USN 52L/R)
Gain COPY - Activates outputs to printer, transmit DAC/TCG
(USN 52L/R) • Multi-echo or inter face-to- • Direct printing of inspection 0 to 110 dB controllable in selectable gain to data logger, output data logger repor t 40 dB Dynamic Range with 6 dB/µsec slope
• RF display mode improves first thickness measure- repor ts. steps 0.1, 0.5, 1.0, 2.0, 6.0, and 24.0 ZOOM - Expands A-Scan display area for
Memory
signal evaluation and bond ment mode, with selectable (24dB step is programmable to other values) increased screen resolution
Lightweight, advanced and MAGNIFY - Expands area within gate for
USN 52L: 100 Dataset memor y locations
inspection of dissimilar ma- flank or peak detection. reliable Test Modes
increased A-Scan resolution in selected area
USN 52R: 140 Dataset memor y locations
terials and assists crack tip • A-Scan freeze, freeze peak, Pulse echo and dual A-Scan preview function, alphanumeric
• 6 pounds (2.7 kg) total Pulser
FREEZE - Captures current screen image or
naming of datasets, director y of all datasets
detection and sizing. and zoom functions. weight with batteries. allows continuous capture of echo peaks
with memor y flag for filled datasets, rapid
Spike/excitation pulse LOCK - Locks against inadver tent change of
(USN 52L/R) • Lock key prevents ac- • Sealed case and membrane clear function, memo functions
Pulse Repetition Frequency parameter values except gain control
• Selectable rep rate cidental change of settings. keypad are splashproof, Selectable, low & high; varies w/range dB REF - Records current gain then allows Other Functions
minimizes wraparound. Documentation and recording rugged and easy to clean Rectification changes to be separately noted; amplitude Cur vature correction, movable gate in freeze
evaluation then related to reference echo mode, auto-calibration of material velocity
• Selectable damping control • On-board thickness data • Operates on AC or 6 “D” size Positive halfwave,negative halfwave,fullwave
and probe zero
amplitude
provides transducer logger stores a total of alkaline or NiCad batteries in Reject (suppression) dB STEP - Selects gain increments Outputs
matching for broader range 2,500 readings in up to 99 a detachable housing
Controllable 0 to 80% absolutely linear HOME - Returns instrument to basic menu Analog TOF & Amplitude, TTL Go/NoGo, Sync
of applications. configurable files.
Units
Optional
Inch or millimeter selectable
• Angle beam trigonometric • RS-232 bidirectional DGS, JIS evaluation
functions display sound interface for transferring Krautkramer Branson Krautkrämer GmbH & Co. Buehler Krautkramer Ltd Krautkramer France Krautkramer Italiana,
path, projection, and depth data, A-scan displays, and 50 Industrial Park Road Rober t-Bosch-Str.3 University of War wick ZAC Sans Souci una divisione della
measurements to flaw. repor ts to a printer, com- Lewistown, PA 17044 D-50354 Hür th (Ef feren) Science Park 68, Chemin des Ormeaux Krautkramer France SA
Tel: 1-717-242-0327 Postfach 1363 GB-Coventr y CV4 7HS 69 760 Limonest France 68, Chemin des Ormeaux

USNLBRPF8985K
puter, and for remote control. Fax: 1-717-242-2606 D-50330 Hür th Tel: +44-1203-690069 Tel: +33-47-217-9220 69 760 Limonest France

Printed in USA
E-Mail: infolink@krautkramer.com Tel: +49-2233-601-0 Fax: +44-1203-693032 Fax: +33-47-847-5698 Tel: +167-790-880
Our facility’s quality Fax: +49-2233-601-402 E-Mail: buehlerkrautkramer Fax: +167-780-881
system conforms to
ISO 9001. E-Mail: Hotline@Krautkramer.de @compuser ve.com
ANSI/ASQC Q91.
www.krautkramer.com

You might also like