FIXTURE COMPUTATIONS:

QUANTITY FIXTURE TYPE DFU TOTAL


1 WATER CLOSET 4 4
1 LAVATORY 1 1
2 FLOOR DRAIN 2 2
2 KITCHEN SINK 2 2
9 DFU

SOIL STACK: 9 DFU 51 mm Ø


SOIL PIPE: 9 DFU 65 mm Ø
MAIN VENT: 9 DFU 65 mm Ø
KITCHEN VENT: 2 DFU 51 mm Ø

WATER PIPELINES COMPUTATIONS:


LOT AREA: 240 m2
FLOOR AREA: 150 m2
OCCUPANCY TYPE: RESIDENTIAL
FIREWALL/WITHOUT: WITHOUT
% OPEN SPACE: 9%
FLOOR TO FLOOR HEIGHT: 2.8 m
FIXTURE QUANTITY WSFU TOTAL
WATER CLOSET 1 4 4
LAVATORY 1 1 1
KITCHEN SINK 1 2 2
TOTAL: 7 DFU

MAX. DEMAND = TOTAL DFU*8 GALLONS


= 7*8
= 56 GALLONS
PROBABLE OF SIMULTANEOUS = MAX.DEMAND *%OF SIMULTANEOUS USE
= 56 * 30%
= 16.8
SIZING OF PIPE = 38 mm Ø

STORM PIPE COMPUTATION


RAINFALL INTENSITY = 210 mm
ROOF AREA = 146.4 m2
SIZE OF STORM DRAIN PIPE = 102 mm Ø

SEPTIC TANK COMPUTATION


VOLUME = 0.086 (100) = 8.6 m2
WIDTH = 1.5 m
HEIGHT = 1.7 m
L = H/(H*W) = 8.6/(1.5*1.7) = 3.37 m
TOTAL LENGTH = 2(3.37)
= 6.74 m