Professional Documents
Culture Documents
General Characteristics: Descriptive
General Characteristics: Descriptive
GENERAL CHARACTERISTICS
ESP PRP
Voltage Standby Amps
kWe kVA kWe kVA
This document is not contractual - The KE&S company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
JD165M
ENGINE SPECIFICATIONS
AIR INTAKE
EMISSIONS Max. intake restriction (mm EC) 625
Emission PM (mg/Nm3) 5% O2 80 Intake air flow (L/s) 170
Emission CO (mg/Nm3) 5% O2 150
Emission HC+NOx (g/kWh) 0
Emission HC (g/kW.h)
This document is not contractual - The KE&S company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
JD165M
ALTERNATOR SPECIFICATIONS
This document is not contractual - The KE&S company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.
JD165M
CONTROL PANEL
DSE Deep Sea Electronics 4610 Standard DSE Deep Sea Electronics 6010 optional
The DSE 4610 MRS is a versatile unit which can be The DSE 6010 MRS is a versatile control unit which
operated in manual or automatic mode. It offers the allows
following features: operation in manual or automatic mode
Measurements: Measurements:
phase-to-neutral and phase-to-phase voltages, voltage and current, kW/kWh/kVA power meters
(In option: active power currents, effective power, Standard specifications: Voltmeter, Frequency meter.
power Optional: Battery ammeter.
factor, oil pressure and coolant temperature levels) J1939 CAN ECU engine control
Supervision: Alarms and faults: Oil pressure, Coolant temperature,
Modbus RTU communication on RS485 Over speed, Start-up failure, alternator min/max,
Reports: Emergency
(In option: 2 configurable reports) stop button.
Safety features: Engine parameters: hour counter, battery
Over speed, oil pressure, coolant temperatures, voltage.
minimum and maximum voltage, minimum and Optional (standard at 12V): Oil pressure, water
maximum frequency temperature.
(Maximum active power P<66kVA) Event log/ Management of the last 50 gen set events.
Traceability: Mains and gen set protection
Stack of 50 stored events Clock management
For further information, please refer to the data sheet USB connections, USB Host and PC,
for the DSE 4610. Communications: RS485 INTERFACE
Mod BUS protocol /SNMP
Optional: Ethernet, GPRS, remote control, 3G, 4G,
Web supervisor, SMS, E-mails
This document is not contractual - The KE&S company reserves the right to modify any of the characteristics stated in this document without notice, in a constant effort to
improve the quality of its products. *ISO 8528.