Professional Documents
Culture Documents
SCD4500 Drive Unit FEA Report of Load Cell / Clevis Pin Mount
SCD4500 Drive Unit FEA Report of Load Cell / Clevis Pin Mount
SCD4500 Drive Unit FEA Report of Load Cell / Clevis Pin Mount
Table of Contents
2 Material ........................................................................................................................................ 5
3 FEA Result................................................................................................................................... 5
4 Conclusions ............................................................................................................................... 10
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
1 Design Drawing
The design drawing is as indicated in Page 7 of this report.
2 Material
The material of Part 1 is Grade 600 MPa yield strength to AS3678/9 or Equivalent.
The material of Part 2 is AS3678/9 – Gr. 350 MPa.
3 FEA Result
Part 1
Part 2
1
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
3.2 Mesh
2
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
Restraints
3
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
3.4 Deformation
Total Deformation
4
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
5
SCD4500
Load Cell / Clevis Pin Mount - FEA
Revision : A
4 Conclusions
The maximum von-Mises stress is less than material allowable stress level for both items.
Design is approved at 2,052kN load case by FEA study
Note that this design assumes full contact of these two items.