manufacturer of evaporative cooling towers

Product and Services Guide


History Products and Services Guide

CONTENTS
Page
Introduction
2 History
3 Table of Contents
4 Decades of Service
5 Technology & Advancement

Advantages
RTA SERIES RTCS SERIES 6 Direct Drive
Axial Fan, Induced Draft Axial Fan, Forced Draft ANTZ: Advanced Nozzle Technology
Counter flow Cross flow 7 iD: Intelligent Control
Direct Drive Direct Drive 8 CoolCore: Wet Deck
Medium to large HVAC Small HVAC 9 Overview of Tower Features
Capacity 60 - 260 tons Capacity 6 - 270 tons
180 - 780 GPM 18 - 810 GPM Tower Series
Cool Water Technologies is part of the Rosenwach family. Founded in Page 10 Page 13 10 RTA Series
1866, Rosenwach has over 150 years of experience in providing cost-effective, innovative 11 RT Series
and professional products and services. Cool Water Technologies brings Rosenwach’s 12 RTC Series
four generations of commitment to the manufacture of advanced technology cooling 13 RTCS Series
towers. Cool Water Technologies installs, maintains, repairs and retrofits cooling towers 14 RTCH Series
15 RTCF Series
made by Cool Water Technologies and all other manufacturers.
16 RTAC Series

Cool Water Technologies’ expertise is built on generations of work: Services


• Rosenwach installed, rigged, repaired and retrofitted hundreds of cooling towers. 17 Water Treatment: Greenclean
RT SERIES
Rosenwach is the premier field assembler and installer of rigged towers. Axial Fan, Induced Draft 18 Plate Heat Exchangers
• Through the 1970’s, Rosenwach made wet deck for large refineries. Cross flow 19 Water Treatment:
• During the 50’s, 60’s and 70’s, Rosenwach was the largest manufacturer of wooden Direct Drive Filters & Cleaning
Medium to large HVAC RTCH SERIES 20 Retrofitting & Restoration
wet decks.
Capacity 200 - 1400 tons Centrifugal Fan, Forced Draft 21 Replacement Parts
600 - 4200 GPM Counter flow 22 Warranty
Today, Cool Water Technologies’ technological advantage is built on the latest Page 11 Small HVAC
Thermal Performance Guarantee
Capacity 12 - 180 tons
developments in controllers and real-time information systems. Our experience allows 23 Company Service Overview
36 - 540 GPM
us to tailor the best made tower to your needs with the most advanced controls allowing Page 14
the most efficient operation, making your tower easier to run. Most of all, Cool Water
Technologies brings you the Rosenwach proven track record of service. Cool Water
Technologies is on-time, knowledgeable, and cost-effective.

RTC SERIES RTCF SERIES RTAC SERIES


Axial Fan, Induced Draft Centrifugal Fan, Forced Draft Axial Fan, Induced Draft
Cross flow Counter flow Closed circuit counter flow
Direct Drive Small HVAC Direct Drive
Medium to large HVAC Capacity 16 - 280 tons Medium to large HVAC
Harris Julius Wallace Andrew
Capacity 120 - 440 tons 48 - 840 GPM Capacity 60 - 260 tons
360 - 1760 GPM Page 15 180 - 780 GPM
Page 12 Page 16
2 3
Decades of service means we know cooling towers Cool Water Technologies is technology
inside and out advancing the industry

We’re on the job around-the-clock, seven days a week, ensuring that towers are kept at peak
performance. From piping and filtration to electrical, tower management and BMS, we go the extra
mile when it comes to service. Contact your Cool Water Technologies representative today at
(866) 706-7072 or go online at coolwatertech.com.

Computer Assisted iD Control Continual filtration


Design & Manufacturing iD cures the common VFD ills: heavy Full integration with high-efficiency
CWT manufactures its towers and parts maintenance load, loss of performance, filtration minimizes corrosion and
to exacting standards using state-of-the- downtime, high operating costs and deposits and lowers static pressure.
art CAD specified plasma cutting. Our multiple units. Peak efficiency is maintained throughout
towers are pre-fit and adjusted. the life of the unit. Filter is managed via
Comprehensive Skill iD and never becomes a headache.
Massive Mixed Use Building, 50-Story Office Tower
Lower Manhattan 9000 GPM field installation of supplemental
CWT moved and installed two cells of a tower cells. CWT completed the job within
1500 ton cooling system. Comprehensive a limited window on time.
piping upgrade was completed
before deadline.
24-7-365
Premium 40-Story Midtown
Office Tower, NYC
A CWT field installation added
capacity to existing infrastructure
with a minimally invasive presence and Materials Wet deck Footprint
timely performance.
Using the best time-tested materials along CoolCore fill lasts longer, keeps its rated More effective management of your
with modern composite matrix casings performance longer and resists corrosion tower with modern technology means
and louvers means your tower is stronger, and deposits better. When used with iD you worry less, have better cooling and
Trust High Security
deterioration resistant and lighter while tower management and CWT integrated save on costs - all at the same size or a
Large Hotel, Westchester Midtown Office Tower loads and stresses are reduced. filtration, you may actually need a smaller smaller tower than existing models.
This busy hotel did not want a crane on CWT installed unit under a highly tower to provide the same cooling. CWT will further customize designs to
site and wanted noise minimized. Field regimented work procedure without customer specifications.
installation was accomplished on time. disturbing occupants of a high security
building on schedule.
Water
Consumption

Ingenuity
Power Thermal
National TV Network Studio Consumption Efficiency
CWT teams worked day and night on a
long holiday weekend during summer
season to replace both cells of a 3000 Electrical
Efficiency
Effective GPM tower while the studio kept working.

effective Experience Modular Green Direct Drive


15000 GPM Power Plant, Bronx A-Class Office Building, Midtown Results in 20% cost savings by optimizing Higher efficiency means less power use Direct Drive is more efficient than belts
CWT replaced entire splash bar wet deck, CWT cut louvers in bulkhead wall and the relationships between water and more efficient use of water, lowers and pulleys, requires less maintenance
rebuilt valves and installed all new louvers replaced 3600 GPM tower one cell at a consumption, thermal efficiency, electrical cost of operation and results in a and adjustment and results in less drive
and stainless steel casing, all on schedule. time while keeping the building on line. efficiency and power consumption. cleaner environment. system failure.
4 5
Direct Drive is more efficient Controls: iD is the
Products and Services Guidecure
2009 for VFD
Direct Drive runs 7% more efficiently than belt driven. iD matches VFD function but does much more. iD integrates up to
It requires less maintenance and is protected from corrosive elements. 10 essential parameters to control your tower and works seamlessly with CWT’s Direct Drive.

Fan Belts are a major A smarter tower is a Monitors multiple data points
source of friction more efficient tower for optimal performance and
energy conservation.
Fan belts lose 4 - 7% efficiency depending iD uses the latest embedded
on the size of the motor. Add in microprocessor technology to provide Wireless: we can monitor your tower in
maintenance, adjustment, replacement real time monitoring and control of the our central office.
and stocking of replacements - belt drives metrics that affect your tower.
cost a lot to operate. The iD Direct Drive Permits remote operation
uses half as many bearings, resulting in Choose a fully integrated solution for up to one mile.
half as many bearing failures. Your iD complete tower management or the
Direct Drive will also last longer because modular function you need. Handles multiple fans.
there is no belt tension perpendicular to
the shaft wearing out your bearings. You Integrates with BMS.
will have no belt dust and no belt noise. iD is Backnet compatible.
It’s cleaner, quieter and overall a more
stress free drive. Active DSP. Minimizes building wire
and cable.

Compatible with all types of towers.

Fully integrated system includes:


Variable speed of fan (up to 4 motors)
Make-up water shut off
An iD retrofit to your existing tower Say goodbye to: balancing, lubrication and Hi-low levels in the cold water basin
replaces outmoded belts and pulleys with adjusting belt tension. Temperature of the cold water basin
the advanced direct drive component Motor vibration
Start saving money today. that minimizes wear and tear, simplifies The iD Retrofit is easy. Your tower will be Chemistry
Retrofit your existing belt maintenance, and saves you money by back in service at a higher efficiency than Turbidity
operating your tower more efficiently. from the original manufacturer and will Static pressure
drive tower. continue running at lower stress points. Tower efficiency
Your savings start immediately!
Modular solutions are also available.
In cases where only a specific parameter
is required, single modules provide
exactly the functionality required.

Low voltage.

ANTZ: Advanced nozzle technology All models ‘talk’ to each other.


ANTZ nozzles clean themselves. CWT offers standard replacement nozzles.
Sensor is UL listed.

All models resist salt air corrosion.


ANTZ nozzles are available for cross flow
induced draft towers. iD communicates with the chiller.

High quality standard replacement nozzles


fit all manufacturers’ towers, offering
improved water flow.

6 7
Wet Deck: where the water meets the air State-of-the-art features • Excellent build quality
CoolCore High Performance Fill keeps CWT towers at top performance. It spreads water for maximum heat CWT towers are built to excel under the toughest conditions.
transfer, minimizes drift and water loss and excessive power consumption.

We offer direct replacement C-1 Cross fluted counter flow MATERIALS Cold Water Basin Maintenance
styrene fill or CoolCore’s Provides maximum thermal performance Composite Matrix or Heavy Duty G235
and Hot Water Basin Hinged Access doors are provided for
composite matrix fill for CWT where water quality is good. (Z700 metric) galvanized steel construction Galvanized 235 Steel. Stainless Steel convenient access to the plenum section
• Pressure drop is minimized while casing and louvers are standard. Optional 304 welded pans are optional for extreme for inspection or maintenance. Options
or other manufacturers’ towers. 304 Stainless Steel construction for include handrailing around the top of the
maintaining thermal performance. conditions. Easy-Clean Sloped Basin
extreme environments. UBC 1997, Design and adjustable non-ferrous tower, external ladder with safety cage to
A complete fill solution for CWT and all • Offered in a range of channel sizes
importance factor 1.0 and specified to make-up valve permit easy adjustment the base of the tower and to the top of
manufacturers’ towers. to permit lower quality water,
Seismic Zone 2B conditions and 30 psf for trouble free control of the water level. the tower and an internal grated walkway
CoolCore fill assures you of maximum while maintaining very high
winds anchorage requirements. The water outlet operates to ensure the with ladder leading to the motor and
cooling at installation and long term. Our H-2 Herringbone cross flow thermal performance.
unrestricted flow of water in the system fan mechanism.
fills are 0.15 mil, specified for the full range
A high quality hanging sheet fill available with strainers of smaller tolerance than
of water grades, with Vertical, Offset
with integral drift eliminators and louvers. CONSTRUCTION the distribution nozzles. The CWT
Vertical, Cross fluted and Herringbone
anti-vortex design prevents air entering
configurations, in a full selection of sheet • The herringbone design maximizes The structural integrity of the framing and
from the system. The water outlet
spacings, bottom supported packs and heat transfer. internal construction is optimized through
connection is compatible with welded or
hanging sheets. • Available in all sizes and sheet spacings expert installation by the experienced
mechanical coupling.
to use with any cooling tower and most CWT team to satisfy the most demanding
water conditions. locations. Optional seismic and wind
rated construction.
• Easy installation; no separate purchase
and installation of louvers and drift
eliminators required.

8 9
RTA Series RT Series
counter flow • induced draft • medium to high capacity cross flow • induced draft • medium to high capacity
provides maximum cooling with cold weather tolerance provides maximum cooling with easy maintenance

Height
Height

Single Cell Width Length

Single Cell Width Length


BASIC Measurements
BASIC Measurements The RT Series is available in sizes from
200 nominal tons (single cell) up to 1400
The RTA Series is available in sizes from nominal tons (double cell), 600 - 4200
60 - 260 nominal tons (single cell) up to GPM. All standard box sizes are available.
520 nominal tons (double cell), 190 to Full range of standard sizes and footprint
1600 GPM. All standard box sizes are available in specification sheet. CWT
available. Full range of standard sizes and will custom design and fabricate for sizes
footprint available in specification sheet. outside this range.
CWT will custom design and fabricate for
sizes outside this range.

Field and Factory Installed


WATER
Field and Factory Installed WATER DISTRIBUTION
FAN DISTRIBUTION
FAN
COOLING WATER FAN
WATER FLOW
OW

CWT FILM FILL AIR FLOW


FL

RADIANT
ARRAY AIR MEDIA
FILM FILL
OW

MEDIA
FL

AIR
COLD WATER BASIN COLD WATER BASIN
COLD WATER BASIN

RTAC RT RTCS
WATER
DISTRIBUTION WATER
WATER
DISTRIBUTION WATER Modul ar Design
WATER
DISTRIBUTION DISTRIBUTION DISTRIBUTION
WATER
Modul ar Design FAN FAN HOT FAN DISTRIBUTION The RT Series is designed in modular
PROCESS FAN
WATER IN COOLING WATER FAN sections to minimize weight and size and
The RTA Series is designed inFILMmodular WATER FLOW
reduce crane installation costs.

OW
OW

FILM FILL CWT AIR FLOW


M FILL FL FILM FILL
sectionsFANto minimize weight MEDIA
and
FILL size and

FL
MEDIA RADIANT
MEDIA AIR COOLED
ARRAY AIR MEDIA
PROCESS FILM FILL

OW
OW
OW

reduce
AIR FLOW crane installation costs. WATER OUT
Frame Construction
MEDIA

FL
FILM
FL
FL

AIR AIR FILL AIR


MEDIA COLD WATER BASIN COLD WATER BASIN
ATER BASIN COLD WATER BASIN
Vertical Design FAN COLD WATER BASIN COLD WATER BASIN The RT Series is frame constructed
for increased durability and longer
RT RTCS
COLD WATER BASIN

RTCF
Air recirculation is minimized
vertical design.
by
RTA RTC RTAC service life.
RTCH WATER Anti-CloggingWATER
Nozzles
DISTRIBUTION WATER
All-Side Access WATER DISTRIBUTION
DISTRIBUTION
DISTRIBUTION Wet deck is equipped with large orifice
FAN FAN
Access to the cold water basin is on all These towers feature: Intelligent Water Distribution System CoolCore Sheet and Block Fill offers anti-clogging nozzles.
four sides of the tower via quick release superior heat transfer and withstands
iD Intelligent Control

OW
louvers panels. Heavy Duty Construction:
FILM FILLcomposite FAN
FILM
corrosion and biological attack
FILL
FILM FILL
MEDIA Stainless Steel Suction
FL Strainer
AIR
matrix, stainless steel MEDIA
and galvanized MEDIA

OW
OW
Direct Drive options AIR FLOW Factory tested in accordance to Standard stainless FILM
steel suction strainer is

FL
FL
No-Vortex Strainer CTI standards AI
R AIR FILL
Galvanized or stainless steel cold 10 Year Motor andCOLD
Drive Warranty
WATER BASIN part of the Cool Water
MEDIA Technologies Total
COLD WATER BASIN COLD WATER BASIN
Prevents turbulence and provides smooth water basin FAN Protection Layer to eliminate corrosion
COLD WATER BASIN
water exit. and decay.
RTCF RTA RTC
10 RTCH 11
RTC Series RTCS Series
cross flow • induced draft • medium capacity cross flow • forced draft • medium capacity
provides maximum cooling and easy maintenance with single-side flexibility provides maximum cooling and easy maintenance with single-side flexibility
Height

Height
Single Cell Width Length
Single Cell Width Length

BASIC Measurements BASIC Measurements


The RTC series is available in sizes from The RTCS Series is available in sizes from
120 - 440 nominal tons (single cell) and up 6 - 270 nominal tons, 18 - 810 GPM.
to 880 nominal tons (double cell), 384 - 2640 All standard box sizes are available. Full
GPM. All standard box sizes are available. Full range of standard sizes and footprint
range of standard sizes and footprint available available in specification sheet. CWT will
in specification sheet. CWT will custom design custom design and fabricate for sizes
and fabricate for sizes outside this range. outside this range.

Field and Factory Installed Field and Factory Installed

WATER WATER
DISTRIBUTION DISTRIBUTION
WATER
FAN DISTRIBUTION
HOT
PROCESS FAN
WATER IN COOLING WATER FAN
WATER FLOW
OW

CWT FILM FILL AIR FLOW


FL

RADIANT
COOLED
ARRAY AIR MEDIA
PROCESS FILM FILL
OW

WATER OUT MEDIA


FL

AIR
COLD WATER BASIN COLD WATER BASIN
COLD WATER BASIN

One Stop Install ation


Modul ar Design RTAC RT RTCS WATER WATER May be installed completely assembled with
DISTRIBUTION DISTRIBUTION
WATER
The RTC Series is designed in modular WATER DISTRIBUTION mounted motor and make-up system.
WATER
HOT FAN
sections to minimize weight and size and DISTRIBUTION WATER
DISTRIBUTION
DISTRIBUTION
PROCESS FAN
WATER WATER IN COOLING WATER FAN
reduce crane installation
DISTRIBUTION costs. WATER FLOW

OW
FAN FAN CWT FILM FILL AIR FLOW Frame Construction

FL
RADIANT
COOLED
ARRAY AIR MEDIA
PROCESS FILM FILL
OW

Frame Construction
WATER OUT MEDIA The RTCS Series is frame constructed for
OW

FILM FILM FILL


FL

FILM FILL FAN FILL MEDIA FL AIR


MEDIA MEDIA AIR COLD WATER BASIN increased durability and longer service life.
COLD WATER BASIN COLD WATER BASIN
The RTC Series is frame constructed for
OW
OW

AIR FLOW FILM


FL
FL

increased durability and longer service life. AIR AIR FILL

RT
MEDIA
COLD WATER BASIN
FAN COLD WATER BASIN COLD WATER BASIN RTAC RTCS Anti-Clogging Nozzles
Anti-Clogging Nozzles COLD WATER BASIN Wet deck is equipped with large orifice
Wet deck is equipped with large orificeRTCF RTA RTC WATER WATER anti-clogging nozzles.
RTCH
DISTRIBUTION WATER DISTRIBUTION
WATER DISTRIBUTION
anti-clogging nozzles. DISTRIBUTION
These towers feature: Intelligent Water Distribution System FAN CoolCore Sheet and BlockFANFill offers
iD Intelligent Control
superior heat transfer and withstands Stainless Steel Suction Strainer
Stainless Steel Suction Strainer Heavy DutyFILM Construction: compositeFILM FILL corrosion and biological attack

OW
FILM FILL FL
MEDIA
FAN matrix, stainless
FILL
MEDIA steel and galvanizedMEDIA AIR Standard stainless steel suction strainer is
Direct Drive options Factory tested in accordance to

OW
part of the Cool Water Technologies Total
OW

Standard stainless steel suction strainer is part AIR FLOW FILM

FL
CTI standards.
FL

AIR AIR
of the Cool Water Technologies Total Protection Galvanized or stainless steel cold
FILL
MEDIA
Protection Layer to eliminate corrosion
COLD WATER BASIN 10 Year Motor and Drive Warranty
Layer to eliminate corrosion and decay. water basin FAN COLD WATER BASIN COLD WATER BASIN and decay.
COLD WATER BASIN

12 RTCF RTA RTC 13


RTCH
RTCH Series RTCF Series
counter flow • forced draft • medium capacity counter flow • forced draft • medium capacity
provides maximum cooling with indoor and outdoor flexibility provides maximum cooling with indoor and outdoor flexibility in a different footprint

Height
Height

Single Cell Width Length Single Cell Width Length

BASIC Measurements BASIC Measurements


The RTCH Series is available in sizes from The RTCF Series is available in sizes from
12 - 180 nominal tons, 36 - 540 GPM. 16 - 140 nominal tons (single cell) and up to
All standard box sizes are available. Full 72 - 280 nominal tons (double cell), 48 - 840
range of standard sizes and footprint GPM. All standard box sizes are available.
available in specification sheet. CWT will Full range of standard sizes and footprint
custom design and fabricate for sizes available in specification sheet. CWT will
outside this range. custom design and fabricate for sizes
outside this range.
WATER WATER
DISTRIBUTION DISTRIBUTION
WATER
FAN DISTRIBUTION
Field and
HOT
Factory Installed
PROCESS FAN Field and Factory Installed
WATER IN COOLING WATER FAN
WATER FLOW WATER WA
OW

CWT AIR FLOW DISTRIBUTION DISTRI


FILM FILL WATER
FL

RADIANT
COOLED
ARRAY AIR MEDIA FAN DISTRIBUTION
PROCESS FILM FILL HOT
OW

WATER OUT MEDIA PROCESS


FL

AIR WATER IN COOLING WATER FAN


WATER FLOW

OW
COLD WATER BASIN COLD WATER BASIN CWT
COLD WATER BASIN FILM FILL AIR FLOW

FL
RADIANT
COOLED
ARRAY AIR MEDIA
PROCESS FILM

OW
WATER OUT ME

RT RTCS

FL
RTAC AIR
COLD WATER BASIN
COLD WATER BASIN COLD WA

WATER
RT
WATER
WATER
DISTRIBUTION
DISTRIBUTION WATER
DISTRIBUTION
DISTRIBUTION
RTAC RT
FAN FAN
WATER
DISTRIBUTION WATER DIS
Modul ar Design
DISTRIBUTION
OW

FILM FILM FILL WATER


FILM FILL FAN FILL MEDIA FL DISTRIBUTION
MEDIA AIR
Modul ar Design MEDIA FAN
OW
OW

AIR FLOW FILM


The RTCF Series is designed in modular
FL
FL

AIR AIR FILL


The RTCH Series is designed in modular MEDIA FILM sections to minimize weight, size and
FILM FILL
COLD WATER BASIN FILM FILL FAN FILL MEDIA
sections to minimize weight, size and FAN COLD WATER BASIN COLD WATER BASIN MEDIA MEDIA reduce crane installation costs.

OW
OW
reduce crane installation costs. COLD WATER BASIN AIR FLOW

FL
FL
RTCF RTA RTC AIR
Centrifugal Fan
AIR

RTCH
COLD WATER BASIN
FAN COLD WATER BASIN
Single Side Air Intake Low
COLD WATER BASINsound and extra power overcomes
Accommodates sound-sensitive locations. RTCF RTA
static pressure for external ducting,
RTCH permitting indoor use.

Centrifugal Fan These towers feature: Intelligent Water Distribution System CoolCore Sheet and Block Fill offers
superior heat transfer and withstands Circul ar Access Door
Low sound and extra power overcomes iD Intelligent Control corrosion and biological attack
Heavy Duty Construction: composite
static pressure for external ducting, matrix, stainless steel and galvanized
permitting indoor use. Direct Drive options Factory tested in accordance to
CTI standards
Galvanized or stainless steel cold 10 Year Motor and Drive Warranty
water basin

14 15
RTAC Series Water, tower and media cleaning
closed circuit counter flow • induced draft Greenclean Chem 1 and Chem 2 clean your water, tower surfaces and media for optimal performance
medium to high capacity offered in models with and without fill and lower power costs and water consumption.

Greenclean Chem 1 treats


and conserves water
Height

Chem 1 offers the double benefit of


providing the water treatment you need
to care for system machinery and in the
process satisfying the government’s goal of
Single Cell Width Length reducing the harmful environmental impact
of your water treatment program.
BASIC Measurements
Chem 1 incorporates advanced high
The RTAC Series is available in sizes strength bonding materials and custom
from 60 - 260 nominal tons, 180 - 780 formulates them to a single feed treatment.
GPM, with a range of weights, sizes and This extra-strong bonding ability allows us GREENCLEAN CHEM 2 PREVENTS
flows. Full range of standard sizes and to operate cooling towers at 40-100 cycles
footprint available in of concentration. An increase in the cycles SEVERE SCALING AND FOULING OF
specification sheet. of concentration means a decrease in water TOWER AND FILTER MEDIA SURFACES.
consumption and reduced charges -
Field and Factory Installed a “win-win” situation for all concerned.
The convenient and safe solution to:
Cooling towers use millions of gallons of GREENCLEAN • Chlorine Residual Decline
water. A large percentage of the water
• Elevated DBPs (TTHMs, HPC)
used is dumped into the environment as Your solution for cleaning tanks, cooling towers,
• Increased Turbidity
chemical-laden bleed wastewater. The piping and filtration media
• Inefficient Inspections
advanced technology of WCS performs
• Coating Deterioration
beyond the typical scale and corrosion
• Increased Corrosion
inhibitor by removing existing scale deposits
without system downtime. Consequently,
using extremely high levels of concentration Traditional cleaning methods
more efficiently uses water by reducing are inefficient.
bleed water discharge; excessive bleed-off
Modul ar Design costs are a thing of the past.
The RTAC Series is designed in modular GreenClean is certified for
sections to minimize weight and size and
use in drinking water facilities:
reduce crane installation costs. WATER WATER
DISTRIBUTION DISTRIBUTION
WATER
DISTRIBUTION • Thoroughly removes surface deposits
HOT FAN
Anti-Clogging Nozzles PROCESS
WATER IN WATER
FAN such as iron, manganese, fungi, algae
COOLING FAN
WATER FLOW and bacteria.

OW
Wet deck is equipped with large orifice CWT FILM FILL AIR FLOW
• Works on wood, steel, concrete

FL
RADIANT
COOLED
ARRAY AIR MEDIA
anti-clogging nozzles. PROCESS FILM FILL
OW

WATER OUT MEDIA and fiberglass.


FL

AIR
COLD WATER BASIN • An NSF 60*-certified, spray-on and
Vertical Design COLD WATER BASIN COLD WATER BASIN
rinse-off application.
Air recirculation is minimized by • Can be done on a regular maintenance
vertical design. These towers feature: RTAC RT RTCS schedule.
Heavy Duty Construction:
iD Intelligent Control composite matrix, stainless steel
All-Side Access and galvanized options
WATER
DISTRIBUTION WATER
WATER
DISTRIBUTION
WATER DISTRIBUTION
Direct Drive DISTRIBUTION
Access to the cold water basin is on all CoolCore Sheet and Block Fill FAN FAN
four sides of the tower via quick release Galvanized or stainless steel cold offers superior heat transfer
louver panels. water basin and withstands corrosion and

OW
FILM FILM FILL
FILM FILL FL
biological attack
MEDIA
FAN FILL
MEDIA
MEDIA
AIR
Intelligent Water Distribution System
OW
OW

CWT Radiant Array AIR FLOW


FL
FILM
FL

Factory tested in accordance to AIR AIR FILL


For maximum heat transfer with minimum 10 Year Motor and Drive Warranty CTI standards.
COLD WATER BASIN
MEDIA
COLD WATER BASIN
air resistance and best durability in its class. FAN COLD WATER BASIN

COLD WATER BASIN


16
RTCF RTA RTC 17
Plate Heat Exchanger Services Filter Services
Cool Water Technologies provides PHE’s for new plant construction, expansion of existing Cleaner water means a cleaner tower, cooler water and significant savings.
production lines and replacement of existing units. CWT provides the best clean water solutions in the field.

Single Source Service CLEANING: QUICK, COST EFFECTIVE AND RELIABLE Self-cleaning Sub-micronic cleaning
Low maintenance Scal able install ations
Cool Water Technologies technicians will Ship your entire heat exchanger unit to us. We will remove, clean,
evaluate your requirements and specify
Low water consumption Self-cleaning
Zyglow test and regasket your plates and frames. No media required Low maintenance
the exact size and capacity required. We
set the standard in rapid delivery of new After reassembly, your unit will be hydrotested on each side.
CWT Spin Clean brings disc filtration CWT media filter is the most innovative
units. We will help you ensure that your technology to the cooling tower industry. filter available today. Total fluidization of
facility is ready for the installation when Our non-abrasive cleaning process
Disc filtration technology uses specially the media during backwash allows more
the new units arrive. restores your plates by removing product
designed grooved discs to create thorough cleaning of the media and
buildup and water deposits.
valleys between each disc to trap solids. allows Pep to use finer grains, taking
ZYGLOW Plates are power-washed between Cleaning is accomplished when the discs retention to sub-micronic levels.
TESTED each step in our refurbishment process. are separated and water is backflushed
• Flows to 178 GPM per vessel
through them, removing the solids. The
• Single and multiple vessel systems
We have pl ate heat exchanger Every plate is tested with our process can be automated and consumes
Zyglow system to ensure there low water and low energy. • Particle retention to 0.5 micron
units avail able for:
are no cracks or pinholes. Early • 90 second backwash cycle
• Beverage Industry • Uniquely efficient
detection of plate defects eliminates • 100% media fluidization
• Industrial Production • Precise particle separation
cross-contamination concerns and saves during backwash
• Ethanol Production • Innovative filter design captures and
you costly down-time. • Patented fluidization system
• Chemical Production stores large amount of solids
• Hotels, Hospitals & • Patented vessel geometry facilitates
The clean and tested plates are • Low energy and water consumption
Commercial Buildings backwashing and minimizes dead
fitted with new gaskets . We • Long-term operation with
• Refinery Applications areas in vessel
carefully select the proper adhesives minimal maintenance
• Power Plants for your needs and ensure trouble free • Operation is easy and requires no filter
• Steel Industry service by cleaning and preparing each media replacement
• Many more gasket individually prior to bonding.
• Continuous flow during backwash
The plates are then heat cured at • Corrosion free
over 300 degrees Fahrenheit in our large • Scalable modular system
ovens, assuring a tight bond between the • Can be used where backwash filters
gasket and plate. get blocked

Field Service
As a part of our scope of service, we
offer a range of different service contracts
meeting your specific needs.
This includes:
• Site surveys
• Trouble shooting
• Emergency field service
• Programmed field service

Cool Water Technologies Offers Exchange Programs, CWT MEDIA FILTERS


Inventory Management and Technical Assistance:
• Comprehensive Refurbishment and • New and Used Plate Inventory
Leak Detection Services • Exclusive US Distributor of Thornhill, UK Gaskets
• Emergency Services Available • Comprehensive Gasket
• Plate Pack Exchange Services Inventory Available
• On-site Removal and Re-installation of • Innovative Maintenance Program
plate packs, optional Hydro-Testing • PHE Consulting and Analysis CWT SPIN CLEAN FILTERS

18 19
Restoration Services Parts Department
Rebuild your tower for as little as 1/3 the cost of a new tower. Write off costs immediately as a CWT provides specification state-of-the-art replacement parts for induced draft towers and
maintenance expense. Recover lost cooling capacity and regain your cost efficiency. forced-draft centrifugal towers at highly competitive prices.

Pillow Bearings Forced Air Fan Assemblies CWT Strainers


• Supplied complete with all necessary • Replace your corroded housing or the • Long lasting construction of 304 gauge
hardware including shims, flingers and entire fan stainless steel (corrosion resistant) or
installation instructions • Complete with all necessary housing galvanized steel
• Optional extended lube line to match any forced air tower • Anti-cavitating design
• Sizes to match all manufacturers’ towers • Galvanized or stainless steel • CWT stocks Strainers for all popular towers
• CWT will custom design and fabricate
strainers as needed
CWT guarantees maintaining The best workforce avail able The best technical base avail able
your tower’s designed thermal All skills and crafts are represented, so Cool Water Technologies is continually
performance. Your tower may all your tower needs are available, from inventing and improving tower
sheet metal work to comprehensive piping performance, design and function. We are
exceed its original performance
improvement, demolition and cleaning, a fast moving company that realizes that
while running cheaper with protective coatings, thermal assessment, innovation is the key to better service.
new technologies such as and replacement or improvement of
tower controls. Solid and Shaf ts Motors Mechanical and Motorized
Cool Water Technologies’ iD. But terfly Valves
• Steel or stainless steel • Epoxy surface coating
• Available separately or in Shaft Kits • Triple dipped and baked windings • Epoxy coating
The best knowledge base available complete with bearings, bushings, • 5 or optional 10 year warranty • Extended neck for piping insulation
We maintain an extensive database of hardware, rust inhibitor and • Double sealed bearings • Sizes 12 - 36”
years of cooling tower work. That means installation instructions • Compatible with all major
proven solutions are at your fingertips. manufacturers’ towers
• Primary and secondary seals

Bushings Wheels Fans


• To fit all drive systems • To fit all sizes of all towers • Aluminum Airfoil Blade
• Corrosion resistant finish • Adjustable pitch
• Available in all diameters
Special Parts Fabrication
Custom fit tings are no problem
We make the full range of specialty parts
including custom fittings according to
your specifications.
Sheaves Powerband and V Belts Induced Draf t Fan Screens
• Aluminum-impervious to moist air • Overspecified to 150% of motor • Galvanized or stainless steel
environment horsepower • Fits all induced draft models
• Individually Balanced • Neoprene with polyester cords

20 Thermal performance of CoolCore fill and drive components is guaranteed to equal or improve the parts you are replacing. 21
WarrAnty Company Service Overview

CWT 10 Year/NDL
The CWT towers, Direct Drive, CoolCore
and iD control systems are warranted
against wear and tear (save for Acts of
God / natural disasters) for a period of
ten (10) years provided United Tower
(the CWT service department company)
cleans and maintains the tower annually
at an additional charge. CWT and related
companies are not responsible for
property or consequential damages that
may arise as a result of this work. Install ation
Four generations of New York installation
experience equalling thousands of
installations, repairs and retrofits.

Maintenance
Experience with all major manufacturers’
towers and custom installations.

Thermal Performance Guarantee

Cool Water Technologies Guarantee


of Thermal Performance
owner’s request, Cool Water Technologies to correct the deficiency at no cost to
Cool Water Technologies unequivocally
will send its engineers to the jobsite to the owner. If the equipment is found
guarantees the thermal performance of
conduct a performance test. This test to be performing in accordance with its RestorATION MANUFACTURING Tower Control systems
its equipment as shown on the certified
may be observed by the owner and the certified drawing, the owner is expected
drawings, when the equipment is installed Making old towers better than new with With a 40,000 square foot facility, we are The latest DSP Smart-Tower feedback systems
consulting engineer or their authorized to reimburse the company for its costs
in accordance with good engineering state-of-the-art Cool Water the only tower manufacturer that makes our keep your towers running optimally,
representatives. If the results of the associated with this performance test.
practice. If after installation and start-up Technologies parts. own advanced controls, wet deck and towers preventing problems before they occur.
evaluation show the equipment to be
there is any question regarding thermal in a quality controlled, in-house setting.
deficient, Cool Water Technologies will
performance of the equipment, at the Since our towers are locally manufactured in
make the necessary repairs or alterations
New York, Tri-State area customers pay no
long distance freight charges.

22 23
40-25 Crescent Street, Long Island City, NY 11101
Tel: (718) 729.4900 • Toll Free: (866) 706.7072 • Fax: (718) 482.0661
coolwatertech.com

You might also like