Electrical - E-1

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

SCHEDULE OF LOADS (PB-a)-(PB-b)

PANEL DETAILS
CKT.
LOAD DESCRIPTION SW VOLTS AMPERE WATTS CB MM SQ. THHN
No.
1 LO - 11 4 220 4.78 1100 15 2-3.5 + 1-2.0 15
2 LO - 5 2 220 2.17 500 15 2-3.5 + 1-2.0 15
3 LO - 7 4 220 3.04 700 15 2-3.5 + 1-2.0 15
4 LO - 7 4 220 3.04 700 15 2-3.5 + 1-2.0 15

a b a 5 LO - 10 5 220 4.34 1000 15 2-3.5 + 1-2.0 15 15AT 15AT


a
a a b a
1 2
4 6 CO - 6 220 4.91 1080 20 2-3.5 + 1-2.0 15
5
7 REFRIGERATOR 220 2.09 460 30 2-5.5 + 1-3.5 20
Sa b Sa Sab Sa 15AT 15AT
a b Sab
Sab 8 RANGE 220 13.63 3000 30 2-5.5 + 1-3.5 20 3 4
2 a
a
a Sab a
Sa
9 ACU 1HP 220 8.00 1840 30 2-5.5 + 1-3.5 20
a
15AT 20AT
Sab Sa b 10 CO - 5 220 3.91 900 20 2-3.5 + 1-2.0 15 5 6 C.O.
Sab
a a
a a 11 ACU 1HP 220 8.00 1840 30 2-5.5 + 1-3.5 20
a Sab a Sa
12 ACU 1HP 220 8.00 1840 30 2-5.5 + 1-3.5 20 30AT 30AT
Sa REF 7 8 RANGE
a
13 ACU 1HP 220 8.00 1840 30 2-5.5 + 1-3.5 20
b b
b b b
1
3 Sa 14 CO - 6 220 4.91 1080 20 2-3.5 + 1-2.0 15 30AT 20AT
Sab
DN ACU 9 10 C.O.
a 15 CO - 5 220 3.91 900 20 2-3.5 + 1-2.0 15
a a PB
a Sab 16 SPARE
a 30AT 30AT
ACU 11 12 ACU
a
b b TOTAL 19 82.73 18,780
b b
30AT 20AT
It = 82.73 + 25% (8) = 84.73 AMPS. ACU 13 14 C.O.
Sab Sab a

PORCH 20AT 15AT


C.O. 15 16 SPARE
USE CAPACITY = 100 AMPS
GROUND FLOOR SECOND FLOOR DECK FLOOR USE : 2 pcs - 8.0 sq. mm THHN Copper Wire
LIGHTING LAY-OUT LIGHTING LAY-OUT LIGHTING LAY-OUT 1 pc - 10.0 sq. mm THHN Copper Wire

LEGEND:

PB PANEL BOARD
CONVINIENCE OUTLET (CO)
RANGE CONVINIENCE OUTLET (CO) RANGE
10
6 15 REF CONVINIENCE OUTLET (CO) REF
SERVICE ENTRANCE ACU AIRCONDITION C.O
FLOURESCENT LAMP
( FROM MERALCO ) Sa SINGLE POLE SWICTH
ACU WP Sab TWO GANG SWICTH
ACU
11
2 pcs - 14.0 sq. mm THHN WIRE CIRCIUT BREAKER
9
WP 1 pc - 3.5 sq. mm THHN WIRE M KILOWATTHOUR METER
ALL IN 32 mm dia. RSC
ACU SERVICE ENTRANCE
12

RANGE

8 GENERAL NOTES:
DN 1.ALL WORKS SHALL BE DONE IN ACCORDANCE WITH THE PARTINENT
7 REF 14
M PROVISION OF THE LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE
PB PB WITH THE RULES AND REGULATIONS OF THE NATIONAL AND LOCAL
AUTHORITIES CONCERNED IN THE ENFORCEMENT OF ELEC. LAWS AND
ORDINANCES WITH THE RULES AND REGULATION OF THE UTILITIES
COMPANIES CONCERNED.
13
3.TYPE OF WIRING SHALL BE DONE IN THE FOLLOWING:
ACU A. RIGID STEEL CONDUIT FOR SERVICE ENTRNCE.
B. ELECTRICAL METALIC TUBING FOR RACEWAYS RUNNING INSIDE
CEILING AND DOUBLE WALL PARTITIONS.
PORCH
C. POLYVINYL CHLORIDE PIPE FOR ALL BRANCH CIRCUIT RACEWAY
EMBENDED IN CONC. SLABS AND WALLS AND ALL AUXILIARY SYSTEM
LAYOUTS W/ PROVISIONS FOR GROUNDING BONDING ELECTRICAL
GROUND FLOOR SECOND FLOOR DECK FLOOR RISER DIAGRAM CONTINUITY.
POWER LAY-OUT POWER LAY-OUT POWER LAY-OUT 4.NUMBER OF OUTLET FOR BRANCH CKT. SHALL NOT EXCEED 12 OUTLETS.
5.MINIMUM SIZE OF WIRE FOR CKT. HOMERUN SHALL BE WIRED NO.
3.5mm sq. TW UNLESS OTHERWISE SPECIFIED.
6.GENERAL USE OF RECEPTACLE SHALL BE RATED15A,230 VOLTS.
7.LIGHT CONTROL SWITCH SHALL BE RATED 10A, 230V.
8.ALL MATERIALS & EQUIPMENT TO BE USED SHALL BE NEW & APPROVED TYPE
FOR LOCATION & PURPOSES.
9.MOUNTING HEIGHTS SHALL BE:
A. LIGHT CONTROL SW - 1.40M ABOVE FLR. AT CENTER.
B. CON. OUTLET - 0.30m ABOVE FLR.
C. PANEL BOARD - 1.40 M ABOVE FLR.
D. OTHERS AS INDICATED IN PLANS.

ENGINEER: PROJECT TITLE / LOCATION: APPROVED: REVISION: CONTENTS: SHEET NO.:


LIGHTING LAY-OUT
PROPOSED CONSTRUCTION OF TWO (2) STOREY POWER LAY-OUT E
PRC NO. PTR NO. RESIDENTIAL WITH DECK COMPUTATION OF LOADS
TIN NO. ISSUED AT LEGEND, GENERAL NOTES
RISER DIAGRAM , VICINITY MAP
1
ADDRESS: MARIKINA