Aplio Series Radiology and Shared Service Transducers

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Radiology & Shared Service Transducers

Designed to minimize 11L3 (PLT-705BT)

Linear
operator stress and increase
Frequency Range 4 - 11 MHz
Application Peripheral Vascular

efficiency, our lightweight Biopsy Guide Available

transducers feature
14L5 (PLT-1005BT)
outstanding clinical versatility, Frequency Range 7 - 14 MHz

ergonomic super-flexible Application


Biopsy Guide Available
Breast, small parts

cables, delivering superb


image quality for a wide 14L7 (PLT-1202S)
range of clinical applications. Frequency Range 7 - 18 MHz

Application Intraoperative, MSK

6C1 (PVT-375BT) 18L7 (PLT-1204BT)


Convex

Frequency Range 1 - 6 MHz Frequency Range 7 - 18 MHz

Application Abdomen, OB Application Breast, small parts

Biopsy Guide Available Biopsy Guide Available

6Cs1 (PVT-375SC) 18LX7 (PLT-1204BX*)


Frequency Range 1 - 6 MHz Frequency Range 7 - 18 MHz

Application Abdomen, OB Application Breast, small parts

Biopsy Guide Available Biopsy Guide Available

6MC1 (PVT-382BT) 6CV1 (PVT-375MV)


Volume

Frequency Range 1 - 6 MHz Frequency Range 1 - 6 MHz


Application Abdomen Application Abdomen, OB
Biopsy Guide Available Biopsy Guide Available

10C3 (PVT-674BT) 6MCV1 (PVT-382MV)


Frequency Range 3 - 10 MHz
Frequency Range 1 - 6 MHz
Application Abdomen, OB
Application Abdomen
Biopsy Guide Available
Biopsy Guide Available

11MC4 (PVT-712BT) 9CV2 (PVT-675MVL)


Frequency Range 4 - 11 MHz
Frequency Range 2 - 8 MHz
Application Neonatal head, Pediatric
Application Abdomen, OB
Biopsy Guide Available

10L4 (PLT-604AT) 11CV3 (PVT-681MVL)


Linear

Frequency Range 4 - 10 MHz Frequency Range 4 - 11 MHz

Application Peripheral vascular Application Endocavitary

Biopsy Guide Available Biopsy Guide Available

*Available on Aplio 500


Volume 14LV7 (PLT-1204MV) 5S1 (PST-25BT)

Sector
Frequency Range 7 - 14 MHz Frequency Range 1 - 5 MHz
Application Peripheral vascular, small parts Application Cardiac, TCD

Biopsy Guide Available Biopsy Guide Available

11CL4 (PVL-715RST) 5S2 (PST-30BT)


Endocavity

Frequency Range 5 - 10 MHz Frequency Range 2 - 5 MHz

Application Endorectal: Bi-plane linear/convex Application Cardiac

Biopsy Guide Available (transperineal only) Biopsy Guide Available

10C5 (PVT-770RT) 6S3 (PST-50BT)


Frequency Range 5 - 10 MHz Frequency Range 3 - 7 MHz

Application Endorectal: Bi-plane, end-fire Application Pediatric Cardiac

Biopsy Guide Available Biopsy Guide Available

11C3 (PVT-781VTE) 9S4 (PST-65AT)


Frequency Range 4 - 11 MHz Frequency Range 4 - 9 MHz

Application Endocavitary Application Neonatal Pediatric

Biopsy Guide Available Biopsy Guide Available

11LI4 (PLT-705BTF) P2 (PC-20M)


Pencil
Intraoperative

Frequency Range 4 - 11 MHz Frequency Range 2.0 MHz

Application Abdomen Application CW only

Biopsy Guide Available

11LI4 (PLT-705BTH) P5 (PC-50M)


Frequency Range 4 - 11 MHz Frequency Range 5.0 MHz

Application Abdomen Application CW only

Biopsy Guide Available

11CI4 (PVT-745BTV) 7S3 (PET-508MA)


Transesophageal

Frequency Range 4 - 11 MHz Frequency Range 3 - 7 MHz

Application Abdomen, small parts Application Cardiac

Biopsy Guide Available

11CI4 (PVT-745BTF) 8SM2 (PET-512MC)


Frequency Range 4 - 11 MHz Frequency Range 2 - 8 MHz

Application Abdomen Application Cardiac

11CI4 (PVT-745BTH) 12LI4 (PET-805LA)


Laparoscopic

Frequency Range 4 - 11 MHz Frequency Range 4 - 12 MHz


Application Abdomen Application Laparoscopic
Biopsy Guide Available
Follow us: www.Medical.Toshiba.com @ToshibaMedical +Toshiba Medical Toshiba America Medical Toshiba Medical

TOSHIBA AMERICA MEDICAL SYSTEMS, INC. 2441 Michelle Drive, Tustin CA 92780 | 800.421.1968
©Toshiba America Medical Systems 2016. All rights reserved. Design and specifications are subject to change without notice.
Aplio and Made for Life are trademarks of Toshiba Medical Systems Corporation.

ULBR12328US MOIUS0088EB