Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 8

Usan Choke Valve Sizing

Variables Mininum Flow


Flow 5652.27
Inlet Pressure 61.34
Pressure drop 54.81
Mass fraction of liquid 0.94
Mass fraction of gas 0.06
Vapour pressure of liquid 61.34
Critical Presssure of liq 103.50
Compressibility 0.80
Inputs
Specific heat Ratio, k 1.61
density of liquid 542.45
density of gas 62.91
Valve Size 2.00
Inlet Line Size 3.00
Outlet line size 3.00
dummy CV 2.76
FL 0.90
Pressure drop Ratio factor, XT 0.72
Presure drop Ratio, X 0.89
Geometric Factor, Fp 1.00
Gas Pressure drop Ratio factor, XTp 0.72
Ratio of Specific Heats factor, Fk 1.15
Limit 0.83
outputs Flow Condition Choked
Gas Expasion Factor, Y 0.67
Liquid critical pressure factor, Ff 0.74
Limiting Pressure drop for liquid, Δpf 12.70
Limiting Pressure drop for gas, Δpg 50.64
Valve CV 2.79
Maximum Flow Units
18840.61 Kg/hr
61.34 bar
54.81 bar
0.94
0.06
61.34 bar
103.50 bar
0.80
1.61
542.45 kg/m3
62.91 kg/m3
2.00 inch
3.00 inch
3.00 inch
9.22
0.90
0.72
0.89
1.00
0.72
1.15
0.83
Choked
0.67
0.74
12.70 bar
50.60 bar
9.31
Usan Choke Valve Sizing

Variables
Flow
Inlet Pressure
Pressure drop
Mass fraction of liquid
Mass fraction of gas
Vapour pressure of liquid
Critical Presssure of liq
Compressibility
Inputs Specific heat Ratio, k
density of liquid
density of gas
Valve Size
Inlet Line Size
Outlet line size
dummy CV
FL
Pressure drop Ratio factor, XT

Presure drop Ratio, X


Geometric Factor, Fp
Gas Pressure drop Ratio factor, XTp

Ratio of Specific Heats factor, Fk


Limit
outputs Flow Condition
Gas Expasion Factor, Y
Liquid critical pressure factor, Ff
Limiting Pressure drop for liquid, Δpf
Limiting Pressure drop for gas, Δpg
Valve CV
Usan Choke Valve Sizing

Mininum Flow Normal Flow Maximum Flow Units


25530.40 222081.60 195542.20 Kg/hr
e 82.01 40.01 30.16 bar
p 67.00 24.90 15.15 bar
liquid 0.94 0.99 1.00
gas 0.06 0.01 0.00
f liquid 82.01 40.01 30.16 bar
of liq 191.80 191.80 191.80 bar
ty 0.77 0.88 0.91
tio, k 1.52 1.20 1.20
uid 792.00 817.00 825.00 kg/m3
s 68.20 34.20 25.30 kg/m3
10.00 10.00 10.00 inch
ze 10.00 10.00 10.00 inch
ze 10.00 10.00 10.00 inch
7.87 99.54 130.57
1.18 1.18 1.18
actor, XT 1.00 1.00 1.00
io, X 0.82 0.62 0.50
r, Fp 1.00 1.00 1.00
o factor, XTp 1.00 1.00 1.00
s factor, Fk 1.09 0.86 0.86
1.09 0.86 0.86
on Not Choked Not Choked Not Choked
tor, Y 0.75 0.76 0.80
e factor, Ff 0.78 0.83 0.85
or liquid, Δpf 25.45 9.34 6.34 bar
for gas, Δpg 89.04 34.30 25.85 bar
7.79 100.16 99.99
219691 24045
2390.6 1485.4
Egina Choke Valve Sizing

Variables
Flow
Inlet Pressure
Pressure drop
Mass fraction of liquid
Mass fraction of gas
Vapour pressure of liquid
Critical Presssure of liq
Compressibility
Inputs Specific heat Ratio, k
density of liquid
density of gas
Valve Size
Inlet Line Size
Outlet line size
dummy CV
FL
Pressure drop Ratio factor, XT

Presure drop Ratio, X


Geometric Factor, Fp
Gas Pressure drop Ratio factor, XTp

Ratio of Specific Heats factor, Fk


Limit
outputs Flow Condition
Gas Expasion Factor, Y
Liquid critical pressure factor, Ff
Limiting Pressure drop for liquid, Δpf
Limiting Pressure drop for gas, Δpg
Valve CV
gina Choke Valve Sizing

Normal Flow Maximum Flow Units


327576.09 284848.77 Kg/hr
e 257.46 257.46 bar
p 243.93 243.93 bar
liquid 0.91 0.91
gas 0.09 0.09
f liquid 257.46 257.46 bar
of liq 351.50 351.50 bar
ty 0.82 0.82
tio, k 1.80 1.80
uid 985.23 985.23 kg/m3
s 255.67 255.67 kg/m3
10.00 10.00 inch
ze 10.00 10.00 inch
ze 10.00 10.00 inch
52.71 45.83
0.90 0.90
actor, XT 0.70 0.70
io, X 0.95 0.95
r, Fp 1.00 1.00
o factor, XTp 0.70 0.70
s factor, Fk 1.28 1.28
0.90 0.90
on Choked Choked
tor, Y 0.67 0.67
e factor, Ff 0.72 0.72
or liquid, Δpf 58.32 58.32 bar
for gas, Δpg 231.56 231.56 bar
52.71 45.83
219691 24045
2390.6 1485.4