Miniblue™ Ii Pneumatic Applicators: Customer Product Manual Part 1124393 - 01

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 76

MiniBlue™ II

Pneumatic Applicators
Customer Product Manual
Part 1124393_01
Issued 05/2015

This document contains important safety


information Be sure to read and follow all
safety information in this document and any
other related documentation.

NORDSON CORPORATION  DULUTH, GEORGIA  USA


www.nordson.com
For CE Declaration, refer to equipment documentation.

Nordson Corporation welcomes requests for information, comments, and inquiries about its
products. General information about Nordson can be found on the Internet using the following
address: http://www.nordson.com.

Address all correspondence to:

Nordson Corporation
Attn: Customer Service
11475 Lakefield Drive
Duluth, GA 30097

Notice

This is a Nordson Corporation publication which is protected by copyright. Original copyright date
2015. No part of this document may be photocopied, reproduced, or translated to another
language without the prior written consent of Nordson Corporation. The information contained in
this publication is subject to change without notice.

Trademarks

AccuJet, AeroCharge, Apogee, AquaGuard, Asymtek, Automove, Baitgun, Blue Box, Bowtie, Build-A-Part,
CanWorks, Century, CF, CleanSleeve, CleanSpray, ColorMax, Color-on-Demand, Control Coat, Coolwave,
Cross-Cut, cScan+, Dage, Dispensejet, DispenseMate, DuraBlue, DuraDrum, Durafiber, DuraPail, Dura-Screen,
Durasystem, Easy Coat, Easymove Plus, Ecodry, Econo-Coat, e.DOT, EFD, Emerald, Encore, ESP, e stylized,
ETI-stylized, Excel 2000, Fibrijet, Fillmaster, FlexiCoat, Flex-O-Coat, Flow Sentry, Fluidmove, FoamMelt, FoamMix,
Fulfill, GreenUV, HDLV, Heli-flow, Horizon, Hot Shot, iControl, iDry, iFlow, Isocoil, Isocore, Iso-Flo, iTRAX, Kinetix,
LEAN CELL, Little Squirt, LogiComm, Magnastatic, March, Maverick, MEG, Meltex, Microcoat, Micromark,
Micromedics, MicroSet, Millennium, MiniBlue, Mini Squirt, Mountaingate, NexJet, Nordson, Optimum,
Package of Values, Pattern View, PermaFlo, PicoDot, Porous Coat, PowderGrid, Powderware, Precisecoat,
PRIMARC, Printplus, Prism, ProBlue, Prodigy, Pro-Flo, ProLink, Pro-Meter, Pro-Stream, RBX, Rhino, Saturn,
Saturn with rings, Scoreguard, Seal Sentry, Select Charge, Select Coat, Select Cure, Signature, Slautterback,
Smart-Coat, Solder Plus, Spectrum, Speed-Coat, SureBead, Sure Coat, Sure-Max, Sure Wrap, Tracking Plus,
TRAK, Trends, Tribomatic, TrueBlue, TrueCoat, Tubesetter, Ultra, UpTime, u-TAH, Value Plastics, Vantage,
VersaBlue, Versa-Coat, VersaDrum, VersaPail, Versa-Screen, Versa-Spray, VP Quick Fit, Watermark,
and When you expect more. are registered trademarks of Nordson Corporation.

Accubar, Active Nozzle, Advanced Plasma Systems, AeroDeck, AeroWash, AltaBlue, AltaSlot, Alta Spray, Artiste,
ATS, Auto-Flo, AutoScan, Axiom, Best Choice, Blue Series, Bravura, CanPro, Champion, Check Mate, ClassicBlue,
Classic IX, Clean Coat, Cobalt, Controlled Fiberization, Control Weave, ContourCoat, CPX, cSelect, Cyclo-Kinetic,
DispensLink, Dry Cure, DuraBraid, DuraCoat, DuraPUR, Easy Clean, EasyOn, EasyPW, Eclipse, e.dot+,
E-Nordson, Equalizer, EquiBead, FillEasy, Fill Sentry, Flow Coat, Fluxplus, Get Green With Blue, G-Net, G-Site,
IntelliJet, iON, Iso-Flex, iTrend, Lacquer Cure, Maxima, Mesa, MicroFin, MicroMax, Mikros, MiniEdge, Minimeter,
Multifill, MultiScan, Myritex, Nano, NexJet, OmniScan, OptiMix, OptiStroke, Partnership+Plus, PatternJet,
PatternPro, PCI, PharmaLok, Pinnacle, Plasmod, Powder Pilot, Powder Port, Powercure, Process Sentry,
Pulse Spray, PURBlue, PURJet, Ready Coat, RediCoat, RollVIA, Royal Blue, Select Series, Sensomatic,
Shaftshield, SheetAire, Smart, Smartfil, SolidBlue, Spectral, SpeedKing, Spray Works, StediFlo, StediTherm,
Summit, SureFoam, Sure Mix, SureSeal, Swirl Coat, TAH, ThruWave, Trade Plus, Trilogy, Ultra FoamMix, UltraMax,
Ultrasaver, Ultrasmart, Universal, ValueMate, Versa, Vista, Web Cure, YESTECH, and 2 Rings (Design)
are trademarks of Nordson Corporation.

Designations and trademarks stated in this document may be brands that, when used by third parties for their own
purposes, could lead to violation of the owners' rights.

Never Seez is a registered trademark of Bostik Inc.

Viton is a registered trademark of DuPont Dow Elastomers. L.L.C.

Part 1124393_01 E 2015 Nordson Corporation


Table of Contents i

Table of Contents

Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Alert Symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Responsibilities of the Equipment Owner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Instructions, Requirements, and Standards . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
User Qualifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Applicable Industry Safety Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Intended Use of the Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Instructions and Safety Messages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Installation Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Operating Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Maintenance and Repair Practices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Equipment Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Equipment Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General Safety Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Other Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
First Aid . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Safety Labels and Tags . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
MiniBlue II Expansion Applicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Freedom™ Applicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Dispensing Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
EasyOn™ Feature . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Hose Connector/Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Cordset . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Temperature Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Intended Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Auxiliary Devices and Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Items Needed . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Installation Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Hydraulic and Pneumatic Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Mounting the Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Mounting an Applicator on a New or Existing System . . . . . . . . . . . . . . . . . . . . . 21
Replacing an Applicator on an Existing System . . . . . . . . . . . . . . . . . . . . . . . . . 22
Making the Solenoid Valve Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Connect the Air Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Connect the Triggering Device to a Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . 23
Connecting the Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26
Flushing the Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

E 2015 Nordson Corporation Part 1124393_01


ii Table of Contents

Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Cleaning Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Troubleshooting Table for MiniBlue . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
Inspecting the Applicator Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
Diagnostic Procedures (DPs) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DP1. Check a Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DP2. Check for a Clogged Nozzle or Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
DP3. Check a Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
DP4. Check an RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Repair . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Replacing the Plastic Cover (SlimLine Applicators Only) . . . . . . . . . . . . . . . . . . . . 38
Replacing a Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Replacing a Heater or RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
To Replace the RTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
To Replace the Heater . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Replacing a Solenoid Valve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43

Using the Illustrated Parts Lists . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44


SlimLine Single Module Applicator Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Single Wide and Multi Module Applicator Assembly . . . . . . . . . . . . . . . . . . . . . . . . 47
Replacement Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Cordsets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Solenoid and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Solenoids . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Solenoid Cabling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51
Solenoid Hard Tubing Replacements Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Solenoid Optional Flexible Tubing Connection Kits . . . . . . . . . . . . . . . . . . . . . . 52
Solenoid Accessories and Spare Parts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53
Covers and Gaskets . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54
Non SlimLine Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55
Hose Connectors and Filter Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
Filter Kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57
Applicator-to-Hose Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Insulating Cuffs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Standard Saturn Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
MiniBlue II Sure Bead Nozzles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Heaters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
SlimLine Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59
Standard MiniBlue II Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Retro-Fit MiniBlue II Applicator . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
Thermal Insulating Applicator Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Extension Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61
Maintenance Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Part 1124393_01 E 2015 Nordson Corporation


Table of Contents iii

Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62

Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63

MiniBlue II Applicator Configuration Code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65

E 2015 Nordson Corporation Part 1124393_01


iv Table of Contents

Page Intentionally left blank.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 1

MiniBluet II
Pneumatic Applicators
Safety
Read this section before using the equipment. This section contains recommendations and
practices applicable to the safe installation, operation, and maintenance (hereafter referred
to as “use”) of the product described in this document (hereafter referred to as “equipment”).
Additional safety information, in the form of task-specific safety alert messages, appears as
appropriate throughout this document.

WARNING! Failure to follow the safety messages, recommendations, and hazard


avoidance procedures provided in this document can result in personal injury,
including death, or damage to equipment or property.

Safety Alert Symbols


The following safety alert symbol and signal words are used throughout this document to
alert the reader to personal safety hazards or to identify conditions that may result in damage
to equipment or property. Comply with all safety information that follows the signal word.

WARNING! Indicates a potentially hazardous situation that, if not avoided, can


result in serious personal injury, including death.

CAUTION! Indicates a potentially hazardous situation that, if not avoided, can


result in minor or moderate personal injury.

CAUTION! (Used without the safety alert symbol) Indicates a potentially


hazardous situation that, if not avoided, can result in damage to equipment or
property.

Responsibilities of the Equipment Owner


Equipment owners are responsible for managing safety information, ensuring that all
instructions and regulatory requirements for use of the equipment are met, and for qualifying
all potential users.

E 2015 Nordson Corporation Part 1124393_01


2 MiniBlue II Pneumatic Applicators

Safety Information
S Research and evaluate safety information from all applicable sources, including the
owner-specific safety policy, best industry practices, governing regulations, material
manufacturer's product information, and this document.
S Make safety information available to equipment users in accordance with governing
regulations. Contact the authority having jurisdiction for information.
S Maintain safety information, including the safety labels affixed to the equipment, in
readable condition.

Instructions, Requirements, and Standards


S Ensure that the equipment is used in accordance with the information provided in this
document, governing codes and regulations, and best industry practices.
S If applicable, receive approval from your facility's engineering or safety department, or
other similar function within your organization, before installing or operating the equipment
for the first time.
S Provide appropriate emergency and first aid equipment.
S Conduct safety inspections to ensure required practices are being followed.
S Re-evaluate safety practices and procedures whenever changes are made to the process
or equipment.

User Qualifications

Equipment owners are responsible for ensuring that users:


S receive safety training appropriate to their job function as directed by governing
regulations and best industry practices
S are familiar with the equipment owner's safety and accident prevention policies and
procedures
S receive equipment- and task-specific training from another qualified individual

NOTE: Nordson can provide equipment-specific installation, operation, and


maintenance training. Contact your Nordson representative for information
S possess industry- and trade-specific skills and a level of experience appropriate to their
job function
S are physically capable of performing their job function and are not under the influence of
any substance that degrades their mental capacity or physical capabilities

Applicable Industry Safety Practices


The following safety practices apply to the use of the equipment in the manner described in
this document. The information provided here is not meant to include all possible safety
practices, but represents the best safety practices for equipment of similar hazard potential
used in similar industries.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 3

Intended Use of the Equipment


S Use the equipment only for the purposes described and within the limits specified in this
document.
S Do not modify the equipment.
S Do not use incompatible materials or unapproved auxiliary devices. Contact your Nordson
representative if you have any questions on material compatibility or the use of
non-standard auxiliary devices.

Instructions and Safety Messages


S Read and follow the instructions provided in this document and other referenced
documents.
S Familiarize yourself with the location and meaning of the safety warning labels and tags
affixed to the equipment. Refer to Safety Labels and Tags at the end of this section.
S If you are unsure of how to use the equipment, contact your Nordson representative for
assistance.

Installation Practices
S Install the equipment in accordance with the instructions provided in this document and in
the documentation provided with auxiliary devices.
S This equipment has not been certified for compliance with the ATEX directive nor as
nonincendive and should not be installed in potentially explosive environments.
S Ensure that the equipment is rated for the environment in which it will be used and that the
processing characteristics of the material will not create a hazardous environment. Refer
to the Safety Data Sheet (SDS) for the material.
S If the required installation configuration does not match the installation instructions,
contact your Nordson representative for assistance.
S Position the equipment for safe operation. Observe the requirements for clearance
between the equipment and other objects.
S Install lockable power disconnects to isolate the equipment and all independently
powered auxiliary devices from their power sources.
S Properly ground all equipment. Contact your local building code enforcement agency for
specific requirements.
S Ensure that fuses of the correct type and rating are installed in fused equipment.
S Contact the authority having jurisdiction to determine the requirement for installation
permits or inspections.

Operating Practices
S Familiarize yourself with the location and operation of all safety devices and indicators.
S Confirm that the equipment, including all safety devices (guards, interlocks, etc.), is in
good working order and that the required environmental conditions exist.
S Use the personal protective equipment (PPE) specified for each task. Refer to Equipment
Safety Information or the material manufacturer's instructions and SDS for PPE
requirements.
S Do not use equipment that is malfunctioning or shows signs of a potential malfunction.

E 2015 Nordson Corporation Part 1124393_01


4 MiniBlue II Pneumatic Applicators

Maintenance and Repair Practices


S Perform scheduled maintenance activities at the intervals described in this document.
S Relieve system hydraulic and pneumatic pressure before servicing the equipment.
S De-energize the equipment and all auxiliary devices before servicing the equipment.
S Use only new Nordson-authorized refurbished or replacement parts.
S Read and comply with the manufacturer's instructions and the SDS supplied with
equipment cleaning compounds.

NOTE: SDSs for cleaning compounds that are sold by Nordson are available at
www.nordson.com or by calling your Nordson representative.
S Confirm the correct operation of all safety devices before placing the equipment back into
operation.
S Dispose of waste cleaning compounds and residual process materials according to
governing regulations. Refer to the applicable SDS or contact the authority having
jurisdiction for information.
S Keep equipment safety warning labels clean. Replace worn or damaged labels.

Equipment Safety Information


This equipment safety information is applicable to the following types of Nordson equipment:
S hot melt and cold adhesive application equipment and all related accessories
S pattern controllers, timers, detection and verification systems, and all other optional
process control devices

Equipment Shutdown

To safely complete many of the procedures described in this document, the equipment must
first be shut down. The level of shut down required varies by the type of equipment in use
and the procedure being completed.
If required, shut down instructions are specified at the start of the procedure. The levels of
shut down are:

Relieving System Hydraulic Pressure

Completely relieve system hydraulic pressure before breaking any hydraulic connection or
seal. Refer to the melter-specific product manual for instructions on relieving system
hydraulic pressure.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 5

De-energizing the System

Isolate the system (melter, hoses, applicators, and optional devices) from all power sources
before accessing any unprotected high-voltage wiring or connection point.
1. Turn off the equipment and all auxiliary devices connected to the equipment (system).
2. To prevent the equipment from being accidentally energized, lock and tag the disconnect
switch(es) or circuit breaker(s) that provide input electrical power to the equipment and
optional devices.

NOTE: Government regulations and industry standards dictate specific requirements


for the isolation of hazardous energy sources. Refer to the appropriate regulation or
standard.

Disabling the Applicators


NOTE: Adhesive dispensing applicators are referred to as “applicators” in some
previous publications.

All electrical or mechanical devices that provide an activation signal to the applicators,
applicator solenoid valve(s), or the melter pump must be disabled before work can be
performed on or around an applicator that is connected to a pressurized system.
1. Turn off or disconnect the applicator triggering device (pattern controller, timer, PLC, etc.).
2. Disconnect the input signal wiring to the applicator solenoid valve(s).
3. Reduce the air pressure to the applicator solenoid valve(s) to zero; then relieve the
residual air pressure between the regulator and the applicator.

General Safety Warnings and Cautions

Table 1 contains the general safety warnings and cautions that apply to Nordson hot melt
and cold adhesive equipment. Review the table and carefully read all of the warnings or
cautions that apply to the type of equipment described in this manual.

Equipment types are designated in Table 1 as follows:


HM = Hot melt (melters, hoses, applicators, etc.)
PC = Process control
CA = Cold adhesive (dispensing pumps, pressurized container, and applicators)

E 2015 Nordson Corporation Part 1124393_01


6 MiniBlue II Pneumatic Applicators

General Safety Warnings and Cautions

Table 1 General Safety Warnings and Cautions


Equipment Warnings and Cautions
Type

WARNING! Hazardous vapors! Before processing any


polyurethane reactive (PUR) hot melt or solvent-based material
HM through a compatible Nordson melter, read and comply with
the material's SDS. Ensure that the material's processing
temperature and flashpoints will not be exceeded and that all
requirements for safe handling, ventilation, first aid, and
personal protective equipment are met. Failure to comply with
SDS requirements can cause personal injury, including death.

WARNING! Reactive material! Never clean any aluminum


component or flush Nordson equipment with halogenated
HM hydrocarbon fluids. Nordson melters and applicators contain
aluminum components that may react violently with
halogenated hydrocarbons. The use of halogenated
hydrocarbon compounds in Nordson equipment can cause
personal injury, including death.

WARNING! System pressurized! Relieve system hydraulic


HM, CA pressure before breaking any hydraulic connection or seal.
Failure to relieve the system hydraulic pressure can result in
the uncontrolled release of hot melt or cold adhesive, causing
personal injury.

WARNING! Molten material! Wear eye or face protection,


HM clothing that protects exposed skin, and heat-protective gloves
when servicing equipment that contains molten hot melt. Even
when solidified, hot melt can still cause burns. Failure to wear
appropriate personal protective equipment can result in
personal injury.

Continued...

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 7

Equipment Warnings and Cautions


Type

WARNING! Equipment starts automatically! Remote triggering


devices are used to control automatic hot melt applicators.
HM, PC Before working on or near an operating applicator, disable the
applicator's triggering device and remove the air supply to the
applicator's solenoid valve(s). Failure to disable the applicator's
triggering device and remove the supply of air to the solenoid
valve(s) can result in personal injury.

WARNING! Risk of electrocution! Even when switched off and


electrically isolated at the disconnect switch or circuit breaker,
HM, CA, PC the equipment may still be connected to energized auxiliary
devices. De-energize and electrically isolate all auxiliary
devices before servicing the equipment. Failure to properly
isolate electrical power to auxiliary equipment before servicing
the equipment can result in personal injury, including death.

WARNING! Risk of fire or explosion! Nordson adhesive


equipment is not rated for use in explosive environments and
has not been certified for the ATEX directive or as
HM, CA, PC nonincendive. In addition, this equipment should not be used
with solvent-based adhesives that can create an explosive
atmosphere when processed. Refer to the SDS for the
adhesive to determine its processing characteristics and
limitations. The use of incompatible solvent-based adhesives
or the improper processing of solvent-based adhesives can
result in personal injury, including death.

WARNING! Allow only personnel with appropriate training and


HM, CA, PC experience to operate or service the equipment. The use of
untrained or inexperienced personnel to operate or service the
equipment can result in injury, including death, to themselves
and others and can damage to the equipment.

Continued...

E 2015 Nordson Corporation Part 1124393_01


8 MiniBlue II Pneumatic Applicators

General Safety Warnings and Cautions (contd)

Table 1 General Safety Warnings and Cautions (contd)


Equipment Warnings and Cautions
Type

CAUTION! Hot surfaces! Avoid contact with the hot metal


HM surfaces of applicators, hoses, and certain components of the
melter. If contact can not be avoided, wear heat-protective
gloves and clothing when working around heated equipment.
Failure to avoid contact with hot metal surfaces can result in
personal injury.

CAUTION! Some Nordson melters are specifically designed to


process polyurethane reactive (PUR) hot melt. Attempting to
process PUR in equipment not specifically designed for this
HM purpose can damage the equipment and cause premature
reaction of the hot melt. If you are unsure of the equipment's
ability to process PUR, contact your Nordson representative for
assistance.

CAUTION! Before using any cleaning or flushing compound on


or in the equipment, read and comply with the manufacturer's
HM, CA instructions and the SDS supplied with the compound. Some
cleaning compounds can react unpredictably with hot melt or
cold adhesive, resulting in damage to the equipment.

CAUTION! Nordson hot melt equipment is factory tested with


Nordson Type R fluid that contains polyester adipate
plasticizer. Certain hot melt materials can react with Type R
HM
fluid and form a solid gum that can clog the equipment. Before
using the equipment, confirm that the hot melt is compatible
with Type R fluid.

Other Safety Precautions


S Do not use an open flame to heat hot melt system components.
S Check high pressure hoses daily for signs of excessive wear, damage, or leaks.
S Never point a dispensing hand-held applicator at yourself or others.
S Suspend dispensing hand-held applicators by their proper suspension point.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 9

First Aid

If molten hot melt comes in contact with your skin:


1. Do NOT attempt to remove the molten hot melt from your skin.
2. Immediately soak the affected area in clean, cold water until the hot melt has cooled.
3. Do NOT attempt to remove the solidified hot melt from your skin.
4. In case of severe burns, treat for shock.
5. Seek expert medical attention immediately. Give the SDS for the hot melt to the medical
personnel providing treatment.

Safety Labels and Tags


Figure 1 illustrates the location of the product safety labels and tags affixed to the equipment.
Table 2 provides an illustration of the hazard identification symbols that appear on each
safety label and tag, the meaning of the symbol, or the exact wording of any safety message.

5 6

Figure 1: Safety labels and tags

E 2015 Nordson Corporation Part 1124393_01


10 MiniBlue II Pneumatic Applicators

Safety Labels and Tags (contd)

Table 2 Safety Labels and Tags


Item Part Description
1. N/A WARNING: Hot Surface! Before touching the applicator
body, allow the applicator to cool, or wear
heat-protective gloves. Failure to allow the applicator
body to cool or to wear heat-protective gloves may
cause personal injury.
2. N/A WARNING: Disconnect power and remove system
pressure before disassembly or maintenance. Failure to
follow these instructions may result in serious personal
injury.
3. 600137 WARNING: Disconnect power and remove system
pressure before disassembly or maintenance. Failure to
follow these instructions may result in serious personal
injury.
4. 243352 WARNING: Fire, injury, or equipment damage can result
if cleanout materials do not meet the following
requirements:
a. Minimum flashpoint to be 550_F (288_C).
b. Liquid and vapor to be non-toxic at use temperature in
equipment.
c. Chemical reactions with adhesive and equipment
materials must not be violently heat producing.
d. Cleanout material must not corrode or otherwise
weaken equipment materials.
5. 600103 CAUTION: This applicator is RTD (resistance
temperature detector) controlled. Prior to operation and
before changing adhesive, consult instruction manual for
changing operating temperature. Failure to follow
instructions may result in personal injury or property
damage.
6. 243352 CAUTION: This equipment is factory tested with
Nordson type R fluid containing Polyester Adipate
plasticizer. Certain adhesives may react
with the type R fluid residue to form solid gum, which can
be difficult to remove.To avoid equipment damage,
check with adhesive supplier regarding compatibility and
cleanout procedure before putting adhesive into the
system.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 11

Description
Nordson MiniBlue II automatic applicators apply thermoplastic hot melt adhesive to a
product, providing uniform bead deposition and improved cutoff when used with aggressive
or hard-to-dispense adhesives. Their air-open, air-close dispensing modules allow high
cycle speeds and their compact size allows them to fit between the flaps of most cartons.

MiniBlue II applicators are available in a slim, 18 mm (0.71-in.) single-module design without


plastic cover (34 mm [1.34 in.] with plastic cover), and in a variety of configurable designs,
including single-module and multi-module configurations.

MiniBlue II applicators are manufactured according to the design choices made at the time of
order placement. Refer to Applicator Configuration Code under Technical Data at the end of
this manual for more information.

MiniBlue II Expansion Applicators


MiniBlue II expansion applicators have been designed to fit directly into existing Solid Blue
applications with no modifications to mounting brackets. The nozzle tip is in the same
location as legacy applicators, and the expansion applicators accommodate bar mounting
and direct manifold mounting applications.

Freedom™ Applicators
Freedom applicators are based on the MiniBlue II platform, but can only be used as part of a
Freedom Hot Melt Adhesive Dispensing System. As part of that system, the Freedom
applicator offers the following feature benefits:
S Component Recognition
S On-screen system inventory at the melter, including part numbers and serial numbers.
S Troubleshooting guidance.
S Freedom applicators only work with Freedom hoses.
S Solenoid actuation signal routed through through the Freedom hose (single module
applicator only).
S Melter integrated OptiBond™ bead stitching control, allowing for reduced adhesive
consumption (up to 4 channels per melter).

E 2015 Nordson Corporation Part 1124393_01


12 MiniBlue II Pneumatic Applicators

Description (contd)

Figure 2 shows some typical MiniBlue II applicators. Figures 3 and 4 show the key parts of
two typical MiniBlue II applicators.
NOTE: The illustrations in this manual depict typical MiniBlue II applicators. Your
applicator may differ in appearance.

1 2

Figure 2: Typical MiniBlue II applicators


1. SlimLine single-module applicator with SP solenoid 3. Multi module applicator with SP
valve and plastic hard cover solenoid valve
2. Wide single-module applicator with SP solenoid
valve, soft flexible cover and side mounted cordset

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 13

8 3

6
7

Figure 3: Key parts of a SlimLine single-module MiniBlue II ball and seat applicator
1. Cordset 5. Filter (integrated, not shown)
2. Solenoid valve 6. Applicator cover
3. Mounting bracket 7. Module (under the cover)
4. Hose connector 8. Muffler

E 2015 Nordson Corporation Part 1124393_01


14 MiniBlue II Pneumatic Applicators

Description (contd)

Figure 4: Key parts of a multi-module MiniBlue II ball and seat applicator


1. Cordset 5. Body
2. Solenoid valve 6. Module
3. Mounting bracket 7. Muffler
4. Hose connector/inline filter

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 15

Solenoid Valve
See Figure 5. Solenoid valves may be configured for independent, common, or programmed
module actuation, as described in Table 3.

CAUTION! SP, SP Waterwash, and P1 solenoids run at a maximum 24 VDC. If


voltage exceeds 24 VDC, premature failure will occur.

2
1 3

Figure 5: MiniBlue II Solenoid Valves


1. SD Solenoid 3. P1 Solenoid
2. SP and SP Waterwash Solenoid

E 2015 Nordson Corporation Part 1124393_01


16 MiniBlue II Pneumatic Applicators

Solenoid Valve (contd)

Table 3 Types of Module Air Actuation


Type of Actuation Description
Independent One solenoid valve directly actuates one module. (SP, SD, P1)
NOTE: SD is not available on retrofit applicators
Common One solenoid valve actuates all modules.
NOTE: SP multi-module valves are the only option for
multi-module CA applicators configurations.

NOTE: This type of actuation is not recommended for stitching


applications.
Programmed Two solenoid valves actuate two groups (left and right) of
modules.
NOTE: An SP multi-module valve is the only option for
multi-module PA applicators.

NOTE: This type of actuation is not recommended for stitching


applications.
NOTE: Module performance will be sacrificed proportionately as more modules are
controlled by a single solenoid valve (common or programmed actuation).

NOTE: SP valves are standard for single-module applications. SD valves are used in
applications with limited mounting space.

NOTE: Solenoid response drift comparison:


P1: <1.0 ms
SP Single: <2.5 ms
SD: <5.0 ms
SP Multi: <5.0 ms

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 17

Dispensing Module
Ball-and-seat modules are used in combination with Saturn nozzles, allowing easier
change-out of nozzle sizes and eliminating the need to stock multiple reduced-cavity
modules with different orifice sizes. Needle-and-seat modules are used in combination with
SureBead nozzles. SureBead nozzles perform similar to reduced cavity and zero cavity
nozzles. Because of improved design efficiency, adhesive bead volume may vary slightly
from equivalent Blue Series RC and ZC modules. Adjust the adhesive pressure to
compensate.

A MiniBlue II applicator may have 1-8 modules. Air is supplied constantly to a module
through a solenoid valve. When the applicator is not being triggered, air will flow through the
module's air-close port to keep the module needle on its seat. When triggered, the solenoid
valve will direct air into the air-open port, lifting the needle from its seat to dispense the
adhesive.

EasyOn™ Feature

See Figure 6. All MiniBlue II applicators use the EasyOn feature. The EasyOn feature on the
module mates with the EasyOn feature on the applicator body. The EasyOn feature allows
the module to be installed onto the applicator body, regardless of the orientation of the
applicator body.

Figure 6: EasyOn design

E 2015 Nordson Corporation Part 1124393_01


18 MiniBlue II Pneumatic Applicators

Hose Connector/Filter
Table 4 shows the filter options based on the style of applicator you have.

See Figure 7. All MiniBlue II applicators have a straight, 45-degree, or 90-degree hose
connector and either an integrated or an inline Saturn filter. Saturn filters are available in 50,
100 or 200 mesh screens to meet your requirements.

Table 4 MiniBlue II Selection Options


MiniBlue II
Expansion Applicators
Applicator Type Standard
Spring Closed Air Closed
SlimLine Single
Integrated Filter ------ ------
Module
Wide Body Single
Inline Filter Integrated Filter Integrated Filter
Module
Configured
Inline Filter Inline Filter Inline Filter
Multi-Module

Figure 7: Location of hose connectors and Saturn filters on different applicator


configurations
1. Hose connector (45 degree shown) 3. Hose connector/inline filter
(45 degree shown)
2. Integrated filter (SlimLine single-module applicator)

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 19

Cordset
The applicator cordset may be positioned on either the right or left end, or on the right or left
side of the back of configurable multi-module applicators.

Only top mounted cordsets are available on SlimLine applicators.

See Figure 8. Cordsets are available in water-resistant and T-style versions.

2
1

Figure 8: Cordset types


1. Freedom cordset 3. Water-resistant cordset
2. T-style cordset

Temperature Control
All MiniBlue II applicators use 120-ohm nickel resistance temperature detectors (RTDs) for
precise temperature sensing and for applicator temperature control to within +0.5 _C (1.0 _F)
of a setpoint temperature.

Intended Use
MiniBlue II applicators are specifically designed for industrial applications that require the
deposition of a precisely controlled bead of hot melt material onto a moving substrate. The
applicators are designed to be rigidly mounted, pneumatically operated, and triggered by a
Nordson-approved, electrically controlled solenoid valve. MiniBlue II applicators are
designed for use with Nordson melters and hoses.

Auxiliary Devices and Spare Parts


MiniBlue II applicators should only be connected to approved auxiliary devices. Use only
new Nordson replacement parts or approved factory refurbished parts.

E 2015 Nordson Corporation Part 1124393_01


20 MiniBlue II Pneumatic Applicators

Installation
Applicators are installed using the following six-step process:
S unpack and inspect
S mount
S connect the air supply
S connect the hose
S flush
S install nozzles

Applicators ordered with special options may require additional installation steps that are not
described here.
NOTE: Nozzles must be ordered separately. Refer to Parts for nozzle part numbers.

Items Needed
To ensure a smooth installation, have the following items on hand:
S personal protective equipment for working with hot adhesive
S product manuals for associated equipment (melter, hose, etc.)
S device to lift and position the applicator
S mounting equipment, such as a mounting rod, appropriate for the parent machine
S wiring and 24 VDC power supply for the solenoid valve
S air pressure regulator and air line tubing (Refer to Connect the Air Supply provided in
the following pages).
S automatic applicator hose
S set of standard and metric hex-head wrenches
S flat-blade and Phillips-head screwdrivers
S drain pans and waste containers suitable for waste adhesive
S O-ring lubricant
S anti-seize lubricant

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 21

Installation Guidelines
Use the following installation guidelines for optimum applicator performance.

Mounting
S Mount the applicator such that the nozzle will be as close as possible to the substrate, but
at a distance that works best for your application. Typically, the minimum distance is two
times the diameter of the nozzle orifice.
S Ensure that the mounting location provides sufficient clearance around the rear or sides of
the applicator to allow for removal of the manifold covers.
S Mount the applicator on a rigid support that is isolated from external vibrations and that
prevents the applicator from rotating.
S Insulate the applicator from the support using the insulator provided with the applicator.
S Do not remove the nozzle from the SureBead applicator until it is time to start the system
and flush the applicator.

Hydraulic and Pneumatic Connections


S Use only one fitting to connect a hose to a hose connector on the applicator.
S Insulate hose-to-applicator joints. Insulating cuffs may be ordered separately. Refer to
Parts.
S Use only clean, dry, non-lubricated air.
S Ensure that the plant air supply and regulator provide a minimum of 4 bar (58 psig) to the
applicator solenoid valve.

Unpacking and Inspection


1. Carefully unpack the applicator.
2. Inspect the applicator and inventory the contents of the shipping package. applicators are
shipped fully assembled and typically include the following components:
S mounting clamp
S module(s)
S solenoid valve(s)
Applicators ordered with optional features may be shipped with additional components.

Mounting the Applicator


This section describes the following applicator-mounting options:
S mounting a applicator on a new or existing system
S replacing a applicator on an existing system

The configuration of your equipment and production line may require a variation in the
mounting options described in this section. Regardless of the mounting method used, follow
the guidelines provided in Installation Guidelines.

E 2015 Nordson Corporation Part 1124393_01


22 MiniBlue II Pneumatic Applicators

Mounting an Applicator on a New or Existing System


1. See Figure 9. Slide the applicator mounting clamp(s) onto a 12-mm, 13-mm, or 0.5 in.
mounting bar, or disassemble the clamp(s) and reassemble them (with the applicator and
insulators) onto the mounting bar. Ensure that the insulators are placed between the
manifold and the clamp(s).

1 2
(12 mm, 13 mm or
0.5 in. diameter) 3

Figure 9: Mounting an applicator using the mounting clamp (SlimLine applicator shown)
1. Mounting bar 3. Insulator
2. Clamp

2. Securely tighten the mounting clamp(s).


3. Go to Making the Solenoid Valve Connections.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 23

Replacing an Applicator on an Existing System


NOTE: MiniBlue II applicators are preassembled with a Nordson-approved,
performance-matched solenoid valve.

NOTE: The distance from the mounting rod centerline and the nozzle tip is different on
a slim single-module applicator and a single-module configurable applicator. If you are
replacing a single-module applicator, be sure to the replace the correct applicator style.
1. Relieve system hydraulic pressure and disable the applicator to be replaced. Refer to
Safety.
2. Disconnect the hose from the applicator both electrically and hydraulically.
3. Separate the existing applicator from its mounting. If a mounting clamp will not be reused,
remove it from the mounting bar.
4. Mount the new applicator and insulator onto the existing mounting clamp (or rod) or
disassemble a new applicator's mounting clamp and then reassemble the clamp (with the
applicator and insulator) onto the existing mounting bar. Tighten the clamp securely.
5. Go to Making the Solenoid Valve Connections.

Making the Solenoid Valve Connections


Solenoid valves must be connected to:
S an air supply
S a triggering device, such as a pattern controller or timer

Be sure to refer to the correct triggering device connection procedure for the solenoid valve
on your applicator.

Connect the Air Supply

Connect a clean, dry, non-lubricated air supply to the air inlet on the solenoid valves.

CAUTION! The air line tubing should be 6 mm OD x 4 mm ID for Independent


Actuation (IA) solenoids/applicators, 10 mm OD x 8 mm ID (without adapter) or
8 mm OD x 6 mm ID (with adapter) for Continuous Actuation (CA) or Programmed
Actuation (PA) solenoids/applicators. Using tubing smaller than that specified
may negatively affect applicator performance.

NOTE: Refer also to Installation Guidelines earlier in this section and, if applicable, to
the instructions supplied with the solenoid valve.

E 2015 Nordson Corporation Part 1124393_01


24 MiniBlue II Pneumatic Applicators

Connect the Triggering Device to a Solenoid Valve

See Figures 10 and 11. Connect the solenoid valve cable to the solenoid valve and to the
triggering device.
NOTE: Refer to Solenoid, Tubing and Fittings table in the Parts section for the cable
part numbers.

SP and SP Waterwash Solenoids

CAUTION! Do not use a spiked signal. Doing so will destroy the internally spiked
valve.

1. Connect the brown and blue wires to the 24 VDC signal.

Brown: 24VDC

Black: Not used

Blue: Common

Figure 10: Connecting the cable to an SP and waterwash solenoid valves

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 25

SD Solenoid
NOTE: This cable is approved for non-spiked Nordson pattern controllers with SD
solenoid valves. If used with third-party timers, make sure the output is voltage
protected for inductive loads to avoid damage to the timer.
1. Connect the brown and black wires to the 24 VDC signal.

Brown: 24 VDC

Black: Common

Blue: Not used

Figure 11: Connecting the cable to an SD solenoid valve

E 2015 Nordson Corporation Part 1124393_01


26 MiniBlue II Pneumatic Applicators

P1 Solenoid

CAUTION! Do not use a spiked signal. Doing so will destroy the internally spiked
valve.

1. Connect the brown and blue wires to the 24 VDC signal.

Brown: 24VDC
Black: Not used

Blue: Common

Figure 12: Connecting the cable to the P1 solenoid valve

NOTES:
S P1 requires 1123970 and either 1100687 or 1100688.
S Cable 1123970 includes a circuit that limits the maximum current draw of the attached
solenoid valve.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 27

Attach Accessories to the SP Waterwash Solenoid


Use the waterwash solenoid accessory kit (P/N 1124349) to complete the instructions
given below. This kit is intended for use with SP waterwash solenoids, P/Ns 1124235
and 1124238.

3
1

Figure 13: Connecting the exhaust muffler relocation kit to a waterwash solenoid valve
1. Fittings 3. Unions
2. Tubes 4. Mufflers

1. Make sure that the system is de-energized and the applicator is disabled. Refer to
Safety given earlier in this manual.
2. Using an M4 Hex key attach the two fittings into the solenoid's exhaust ports.
3. Insert a tube into each of the fitting. Make sure it is secure.
4. Install a union onto the opposite end of each of the tube.
5. Insert a muffler into each of the union.
6. Route the tubes downward and away from the applicator.
IMPORTANT: Be sure to secure the ends of the tubes with the Velcro strap provided in
the kit.
7. Resume normal operation.

E 2015 Nordson Corporation Part 1124393_01


28 MiniBlue II Pneumatic Applicators

Connecting the Hose


NOTE: Refer to the user's guide shipped with the hose for detailed hose installation
guidelines.
1. Connect the hose to the applicator.
2. Connect the applicator cordset to the hose.
3. Connect the hose to the melter. Refer to the hose user's guide and/or the melter product
manual as needed.
4. Go to Flushing the Applicator.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 29

Flushing the Applicator


Before the applicator is placed into operation, it must be flushed of foreign material.

WARNING! Risk of personal injury or equipment damage. Do not remove the


nozzle from SureBead applicators until it is time to start the system and flush the
applicators. The sharp needle on these applicators is exposed whenever the
nozzle is removed.

CAUTION! This equipment is factory tested with Nordson Type R fluid containing
polyester adipate plasticizer. Certain adhesives may react with the Type R fluid
residue to form a solid gum that can be difficult to remove. Consult with your
adhesive supplier to determine the compatibility of your adhesive with Type R
fluid.

1. Disconnect or turn off the solenoid valve triggering device.


2. Start the melter and heat the system to the operating temperature and pressure required
for the adhesive being used. Refer to the melter product manual and the instructions
provided with the adhesive as needed.
3. Place a drain pan under the applicator.
4. Remove the nozzle(s) from the applicator. Refer to the nozzle removal procedures under
Cleaning Nozzles later in this manual as needed.
5. Dispense adhesive from the applicator by manually triggering the solenoid valve(s).
6. Stop dispensing when the adhesive flow is clear and free of foreign material.
7. Check for leaks between the applicator, hose, and melter.
8. Install the applicator nozzles.
SureBead nozzles: Install the nozzle by threading it onto the module by hand and then
using a torque wrench to tighten the nozzle to no more than 4.5 Nm (40 in.-lb). Do not
over-tighten. Refer to the nozzle installation procedures under Cleaning Nozzles later in
this manual as needed.

E 2015 Nordson Corporation Part 1124393_01


30 MiniBlue II Pneumatic Applicators

Operation
Refer to the melter product manual for operating instructions.

WARNING! MiniBlue II applicator modules operate as air-open, air-close valves.


The loss or elimination of air pressure to the applicator solenoid valve without a
corresponding reduction in system hydraulic pressure may cause the applicator
modules to remain open.

Maintenance
Table 5 provides the recommended schedule for applicator maintenance. Detailed
procedures for weekly and semi-annual maintenance tasks are provided in the remainder of
this section.

Table 5 Applicator Maintenance Schedule


Frequency Task Notes
Daily Remove hot melt and char
from the exterior of the
applicator assembly.
Weekly Clean the applicator A, B
nozzle(s). Refer to
Cleaning Nozzles.
Semi-annually Inspect the applicator
wiring. Refer to Inspecting
the applicator Wiring.
As needed Replace the filter. Refer to
the instructions supplied
with the replacement filter.
NOTE A: Nordson recommends the use of a nozzle cleaning kit.
B: Process-specific nozzle performance history may indicate the need for more or less
frequent nozzle cleaning.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 31

Cleaning Nozzles
WARNING! Risk of personal injury or equipment damage. Do not remove the
nozzle from SureBead applicators until it is time to start the system and flush the
applicators. The sharp needle on these applicators is exposed whenever the
nozzle is removed.

Applicator nozzles may become clogged when char, a by-product of overheating the hot
melt, becomes lodged in the nozzle.
1. Heat the applicator to operating temperature.
2. Disable the applicator. Refer to Safety.
3. Remove the nozzle. Refer to Table 6.

Table 6 Nozzle removal procedures


Nozzle Type Nozzle Removal Procedure
Saturn Use a wrench to loosen the nozzle; then remove the
nozzle by hand.

SureBead

WARNING! Risk of fire. Do not heat Nordson Type R fluid above 245 _C (475 _F).
Use only an industrial grade, regulated, electrical heating device that is designed
to heat industrial fluids. Personal injury or property damage can result if Type R
cleaning fluid is heated with an open flame or in an unregulated heating device.

4. Soak the nozzles in Nordson Type R cleaning fluid that has been heated above the
melting point of the adhesive, to a maximum of 177 _C (350 _F).
5. Remove the nozzles from the cleaning fluid.

CAUTION! Use the correct size precision pin probe to clean Nordson nozzles.
The use of non-precision or incorrectly sized probes may damage the nozzle. The
Nordson nozzle cleaning kit (part 901915) contains a variety of probe sizes.

E 2015 Nordson Corporation Part 1124393_01


32 MiniBlue II Pneumatic Applicators

Cleaning Nozzles (contd)


6. See Figure 14. At the outlet of each nozzle, insert a correctly sized cleaning probe.
7. With a clean cloth, firmly grip the cleaning probe, then pull the probe out of the nozzle,
wiping the probe clean.

Figure 14: Cleaning a nozzle


8. Reinstall the nozzle. Refer to Table 7.

Table 7 Nozzle installation procedures


Nozzle Type Nozzle Installation Procedure

Saturn Thread the nozzle onto the module threads by hand;


then use a torque wrench to tighten the nozzle to
4.5 NDm (40 in.-lb).

SureBead

9. Restore the system to normal operation.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 33

Troubleshooting

WARNING! Allow only personnel with appropriate training and


experience to operate or service the equipment. The use of
untrained or inexperienced personnel to operate or service the
equipment can result in injury, including death, to themselves and
others, and damage to the equipment.

Troubleshooting Table for MiniBlue II


The following table lists the applicator problems that are most likely to occur, the possible
causes of each problem, and steps for corrective action. Where applicable, cross-references
are made to expanded diagnostic procedures (DPs) provided later in this section or to other
sections of this manual.

Problem Possible Cause Corrective Action


1. No adhesive flow Adhesive level low Add adhesive.
from a single
applicator module
or from any
module on a
multi-module
applicator
No input power Connect power to the melter
and auxiliary devices. Ensure
that all disconnect switches or
circuit breakers are on.
Melter, hose, or applicator Adjust the setting. Refer to the
temperature setting too low melter product manual.
System not at operating Verify that the system ready
temperature light is on and that the adhesive
is molten.
Insufficient air pressure to Adjust the pump air pressure.
melter piston pump (piston
pump melters)
Melter motor not operating Check the motor operation.
(gear pump melters) Refer to the melter product
manual.
No air supply to solenoid Check the plant air supply
valve pressure.
Solenoid valve failed Check the solenoid valve and
replace if necessary. Refer to
DP1.
Hose clogged Replace the hose.
Continued...

E 2015 Nordson Corporation Part 1124393_01


34 MiniBlue II Pneumatic Applicators

Troubleshooting Table for MiniBlue II (contd)

Problem Possible Cause Corrective Action


1. No adhesive flow Nozzle clogged Check the nozzle. Refer to DP2.
from a single
applicator module
or from any
module on a
multi-module
applicator(contd)
Adhesive in air section of Replace the module. Refer to
module the instructions provided with
the module.
Module failed Replace the module. Refer to
the instructions provided with
the module.
Dirty or faulty triggering Clean or replace the triggering
device device.
Faulty encoder Test the encoder and replace if
defective.
2. No adhesive flow Nozzle clogged Check the nozzle. Refer to DP2.
from some
modules in a
multi-module
applicator
Module failed Replace the module. Refer to
the instructions provided with
the module.
3. Uncontrolled Hydraulic pressure too Decrease the system hydraulic
adhesive flow high pressure.
from module
Hydraulic pressure too Stop the melter pump and
high and applicator air restore the air pressure to the
pressure lost applicator.
Module failed to open Replace the module. Refer to
the instructions provided with
the module.
Solenoid valve ported to Correct the solenoid valve
manifold backwards or porting or replace the solenoid
failed to open valve. If applicable, refer to the
instructions supplied with the
solenoid valve.
4. Adhesive or air Air or adhesive seals failed Replace the module. Refer to
flows from bleed the instructions provided with
hole the module.
Continued...

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 35

Problem Possible Cause Corrective Action


5. Modules not Module failed Replace the module. Refer to
triggering at the the instructions provided with
same time on the module.
multi-module
applicator
Insufficient applicator air Increase the applicator air
pressure pressure.
6. Applicator fails to No power Check that the melter is on.
heat or Refer to the melter product
underheats manual.
Applicator temperature Adjust the temperature setpoint.
setpoint too low Refer to the melter product
manual.
Applicator heater failed Check for an open heater circuit.
(open or short) Refer to DP3.
Applicator RTD failed Check the RTD resistance.
(open or short) Refer to DP4.
7. Applicator Tank, hose, or applicator Adjust the setpoint. Refer to the
overheats temperature setpoint too melter product manual.
high
Applicator RTD shorted Check the RTD resistance.
(melter should shut down) Refer to DP4.
Short in heater control Troubleshoot the melter. Refer
circuit to the melter product manual.
8. Freedom melter Component ID (CID) not Refer to Freedom Hot Melt
does not installed or not recognized. Adhesive System Manual.
acknowledge that
an applicator is
installed.
9. Freedom melter Non-Freedom Applicator Refer to Freedom Hot Melt
does acknowledge installed Adhesive System Manual.
that an applicator
is installed but
does not
recognize as
Freedom
approved
applicator.
Damaged or misconnected See pin out and verify RTD and
RTD or cordset. heater resistance.
10. Freedom Refer to Freedom Hot Melt Refer to Freedom Hot Melt
applicator is not Adhesive System Manual. Adhesive System Manual.
stitching
(modulating)
beads when
dispensing.

E 2015 Nordson Corporation Part 1124393_01


36 MiniBlue II Pneumatic Applicators

Inspecting the Applicator Wiring


1. De-energize the system. Refer to Safety.
2. Remove the plastic cover (SlimLine single module applicators only). Refer to Replacing
the Plastic Heater Cover (SlimLine Applicators Only).
3. Remove the manifold cover.
4. Check the internal applicator wiring for signs of damage and the cable connection for
tightness.
5. Reinstall the manifold cover.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 37

Diagnostic Procedures (DPs)


The following diagnostic procedures (DPs) are referenced in the Troubleshooting Table.

DP1. Check a Solenoid Valve


1. Place the system into operation.
2. Trigger the applicator using the timer or pattern controller:
S Adhesive flows—normal indication. Return to the Troubleshooting Table.
S No adhesive flow—go to step 3.
3. Manually trigger the applicator at the solenoid valve:
S Adhesive flows—normal indication. Return to the Troubleshooting Table.
S No adhesive flow—go to step 4.
4. Check the solenoid valve coil for continuity (P1, SG and SD Valves):
S Continuity okay—normal indication. Return to the Troubleshooting Table.
S No continuity—failed solenoid valve. Replace the solenoid valve.

NOTE: Verify that the solenoid valve being used has a rated service temperature
above 85 _C (185 _F).

DP2. Check for a Clogged Nozzle or Module


1. Disable the applicator. Refer to Safety.
2. Remove the nozzle. Refer to Cleaning Nozzles for the nozzle-removal procedure.
3. Place the applicator back into operation.
4. Trigger the applicator:
S Adhesive flows—normal indication. Clean the nozzle. Refer to Maintenance.
S No adhesive flow—the module is clogged. Replace the module. Refer to Repair.

E 2015 Nordson Corporation Part 1124393_01


38 MiniBlue II Pneumatic Applicators

DP3. Check a Heater


1. Disable the applicator. Refer to Safety.
2. Unplug the applicator cordset from the hose.
3. See Figure 15. Test for continuity across the heater circuit (pins 1 and 2):
S Continuity okay—normal indication. Return to the Troubleshooting Table.
S No continuity—the heater is defective. Replace the heater. Refer to Repair.

HEATER 1
HEATER 2 5
RTD 3 4 3
3 4

RTD 5
2 5
1 6
GND 2 1
4

Freedom Wiring:
HEATER 1
HEATER 2
RTD 3 3 4
RTD Common 5 2 5

Gun CID Data 6


1 6

Applicator CID Common


4

Figure 15: Applicator cordset pin positions

DP4. Check an RTD


1. Disable the applicator. Refer to Safety.
2. Unplug the applicator cordset from the hose.
3. Allow the applicator to reach room temperature or use a pyrometer to determine the
temperature of the applicator.
4. See Figure 15. When the applicator temperature is known, measure the resistance across
the RTD circuit (pins 3 and 5).

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 39

5. See Figure 16 to determine the expected resistance of the RTD at the known temperature.
Compare the expected and measured resistance values.

Nickel RTD Temperature in C

Resistance
in Ohms

Temperature in F 4209012A

Figure 16: RTD resistance vs. temperature


S Measured resistance is within the expected range—normal indication. Return to the
Troubleshooting Table.
S Measured resistance is not within the expected range—the RTD is defective. Replace
the RTD. Refer to Repair.

E 2015 Nordson Corporation Part 1124393_01


40 MiniBlue II Pneumatic Applicators

Repair
Refer to these repair procedures as needed. For repair procedures not included in this
section, refer to the instructions supplied with the replacement part.

Replacing the Plastic Cover (SlimLine Applicators Only)


The plastic cover must be removed from the MiniBlue II applicator.
1. Disconnect and lock out power to the MiniBlue II SlimLine applicator.
2. Allow the applicator to cool down to room temperature.
3. Place the side cover insulation into the side covers.
4. Insert M3 screws through side cover(s) and insulation.
5. Screw the right side cover and insulation onto the applicator to 3-5 in-lbs (.34-.56 NDm).
6. Lightly press the module cover into the right side cover.
7. Screw the left side cover and insulation onto the applicator to 3-5 in-lbs (.34-.56 NDm).
8. Turn power back on to applicator.

4
6

4
3

Figure 17: Replacing the plastic cover


1. Module 4. Cover insulation
2. Right cover 5. Module cover
3. Left cover 6. M3 screw

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 41

Replacing a Module
1. Relieve system pressure, and then purge the applicator and hose. Refer to the melter and
applicator product manuals for additional information.
2. Disable the applicator driver.
3. Remove the M4 X 25 module retaining screws, and then remove the module.
4. Using a non-abrasive cloth, remove adhesive residue from the face of the applicator body.

CAUTION! Risk of Burns! Applicator body may be hot! Use caution when cleaning
it.

5. Insert the two O-rings for each pneumatic port, and the one O-ring for the adhesive port.
6. Apply an anti-seize compound (Nordson Corporation PN 900344) to the module retaining
screws, and then install the new module. Tighten the screws to 1.7-2.2 Nm (15-20 in.-lb).

Figure 18: Replacing the module

E 2015 Nordson Corporation Part 1124393_01


42 MiniBlue II Pneumatic Applicators

Replacing a Heater or RTD


RTDs are hardwired through the applicator cordset. If an RTD fails, Nordson recommends
that the entire applicator cordset be replaced. Heaters are terminated inside the manifold
and can be replaced individually without replacing the entire cordset.

The following procedure describes the replacement of an RTD by replacing the entire
cordset. Instructions for replacing a heater are also included.

De-energize the system and disable the applicator. Refer to Safety.

Unplug the applicator cordset from the hose.

(Optional) Relieve system hydraulic pressure. Refer to Safety.

(Optional) Using two wrenches, disconnect the hose from the applicator.
NOTE: Steps 3 and 4 are not necessary if the applicator is easily accessible and can
be serviced without the need to disconnect the hose.

See Figure 19 or 20 as applicable.


1. Remove the applicator cover to access the RTD or heater and remove it from from the
applicator body.
2. Disconnect the cordset leads from the terminal block. If the heater is being replaced,
disconnect the heater leads from terminal block.
3. Do one of the following:

To Replace the RTD


a. Disconnect the ground lead from the manifold and remove the cordset.
b. Install a new cordset and insert the RTD in the manifold.
c. Reconnect the ground lead to the manifold.

To Replace the Heater


a. If necessary, trim the leads of the new heater to match the leads of the old heater.
b. Crimp eyelets (P/N 972862) onto the end of the heater.
c. Insert the heater into the manifold.
d. Insert the heater leads in the terminal block and tighten the terminal block screws.
e. Insert the cordset heater leads in the terminal block and tighten the terminal block
screws.
4. Reinstall the applicator cover. Refer to Replacing the Plastic Heater Cover (SlimLine
Applicators Only) as needed.
5. If the hose was removed earlier, use two wrenches to connect the hose to the applicator.
6. Plug the applicator cordset into the hose.
7. Restore the system to normal operation.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 43

4
10 5

Figure 19: Replacing a heater or RTD on a slim-line applicator


1. Mounting bracket 6. Module
2. M3 screw 7. Heater
3. Cordset heater leads 8. Heater leads
4. Ground wire 9. applicator body
5. Terminal block 10. RTD

E 2015 Nordson Corporation Part 1124393_01


44 MiniBlue II Pneumatic Applicators

Replacing a Heater or RTD (contd)

2
1
3
4

7
6

Figure 20: Replacing a heater or RTD on a single wide or multi module configurable
applicator
1. Cordset heater leads 5. Heater
2. Terminal block 6. RTD
3. Eyelet 7. Ground wire
4. Heater leads

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 45

Replacing a Solenoid Valve


1. De-energize the system and disable the applicator. Refer to Safety.
2. Unplug the applicator cordset from the hose.
3. Relieve system hydraulic pressure. Refer to Safety.
4. (Optional) Using two wrenches, disconnect the hose from the applicator.

NOTE: Steps 3 and 4 are not necessary if the applicator is easily accessible and can
be serviced without the need to disconnect the hose.

See Figure 21.

Figure 21: Replacing a solenoid valve


5. Disconnect the solenoid valve cable.
6. For IA applicators: remove the two screws and washers (1) from of the applicator, and
then remove the solenoid and tubes.
7. For CA or PA applicators: Use two wrenches to remove the tube fittings (2) from the
tubing, and then remove the solenoid.
8. Un-thread the tubes or fittings from the solenoid.
9. Install the new solenoid valve assembly by reversing step 6.
10. Connect the solenoid valve cable.
11. Restore the system to normal operation.

E 2015 Nordson Corporation Part 1124393_01


46 MiniBlue II Pneumatic Applicators

This page intentionally left blank.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 47

Using the Illustrated Parts Lists


To order parts, call the Nordson Customer Service Center or your local Nordson
representative. Use these five-column parts lists, and the accompanying illustrations, to
describe and locate parts correctly. The following chart provides guidance for reading the
parts lists.

The number in the Part column is the Nordson part number you can use to order the
part. A series of dashes indicates that the part is not saleable. In this case, you
must order either the assembly in which the part is used or a service kit that
includes the part.

The Description column describes the part and sometimes


includes dimensions or specifications.

The Note column contains letters that refer to


notes at the bottom of the parts list. These notes
provide important information about the part.

Part Description Note

S
S S
NOTE A:
B:
NS: Not Shown

E 2015 Nordson Corporation Part 1124393_01


48 MiniBlue II Pneumatic Applicators

SlimLine Single Module Applicator Assembly


See Figure 22.
Item Part Description Qty. Note
1 1095703 KIT, REPL, MODULE, MINIBLUE II 1
2 1051289 HEATER PLUG, WATER RESISTANT 1
3 371579 O-RING, VITON, 4 X 1 1
4 ------ HEATER CARTRIDGE, 6MM X 30MM, 1 C
230V, 100W
5 1098830 MANIFOLD, SLIMLINE, MINIBLUE II 1
6 ------ FILTER, APPLICATOR, 100 MESH, 1 D
SATURN, M14
7 ------ RTD 1 B
8 274179 CONNECTOR, HOSE, WITH O-RING, 1
45 DEGREE
9 1098834 GASKET 1
10 1098831 COVER, MINIBLUE II, SLIMLINE 1
11 733548 INSULATOR, MOUNTING BRACKET 1
12 1098832 CLAMP, MOUNTING, BOTTOM 1
13 1098833 CLAMP, MOUNTING, TOP 1
14 ------ WASHER, M6 1
15 ------ WASHER, SPRING, 6MM 1
16 ------ SCREW, SOCKET, M6 X 40 1
17 ------ SOLENOID 1 A
18 ------ SOLENOID MOUNTING TUBE 2 A
19 ------ CORDSET 1
20 ------ SCREW, SOCKET, M4 X 16 2
21 ------ WASHER, LOCK, M4 2
22 ------ SCREW, ALLEN HEAD, M3 X 10 1
23 ------ SCREW, ALLEN HEAD, M3 X 6 1
24 ------ WASHER, LOCK, M3 1
25 1103018 PLASTIC COVER SERVICE KIT 1
26 ------ SCREW, HEX HEAD, M6 X 35 1
27 375291 O-RING, 6 MM X 1 MM 2
NS 939586 CONNECTOR, PORCELAIN, 2STATION 1
NS 940081 O RING,VITON, .188X.313X.063, 10408, 2
MODULE, HYDRAULIC
NS 940090 O RING,VITON,.208ID X .070W, BR, 1
10409, MODULE
NOTE A: Refer to the Solenoid, Tubing and Fittings table provided later in the Parts section.
B: Cordsets include RTD. Refer to the Cordsets table provided later in the Parts section.
C: Refer to the Heaters table provided later in the Parts section.
D: Refer to the Integrated Filters table provided later in the Parts section.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 49

19

17

16
18

26
14, 15
25 27
13
12
11
20 10
21 9 25

8
23
22
24 6
7

1 2 3
25
Figure 22: SlimLine applicator assy.

E 2015 Nordson Corporation Part 1124393_01


50 MiniBlue II Pneumatic Applicators

Single Wide and Multi Module Applicator Assembly


See Figures 23 and 22.
Item Part Description Qty. Note
1 1095703 KIT, REPL, MODULE, MINIBLUE II 1
2 ------ MANIFOLD, MINIBLUE, MULTI-MODULE
3 ------ HEATER CARTRIDGE C
4 ------ RTD B
5 939586 CONNECTOR, PORCELAIN, 2-STATION
6 973574 PLUG, O-RING, 9/16-18
7 ------ GASKET, MINIBLUE, MULTI 1 E
8 ------ COVER, MINIBLUE, MULTI, LS, RS 1 E
9 ------ PAN HEAD SCREW, M4 X 8 5
10 ------ FILTER, SATURN, IN-LINE 1 D
11 ------ CORDSET 1 B
12 ------ ISOLATOR, MOUNTING BRACKET 1 F
13 ------ BRACKET, MOUNTING 1 F
14 ------ WASHER, M6 2
15 ------ WASHER, SPRING, 6MM 2
16 ------ SCREW, SOCKET, M6 X 40 2
17 ------ SOLENOID 1 A
18 ------ TUBE A
NS 940081 O RING,VITON, .188X.313X.063, 10408, 2
MODULE, HYDRAULIC
NS 940090 O RING,VITON,.208ID X 070W, BR, 1
10409, MODULE
NOTE A: Refer to the Solenoid, Tubing and Fittings table provided later in the Parts section.
B: Refer to the Cordsets table provided later in the Parts section. Cordsets include RTD.
C: Refer to the Heaters table provided later in the Parts section.
D: Refer to the Integrated Filters table provided later in the Parts section.
E: Refer to Covers and Gaskets provided later in the Parts section.
F: Refer to Non SlimLine Mounting provided later in the Parts section

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 51

17
16

18 15
14

13

12
11

9
10

2
7

3 5
1 4
6

Figure 23: Multi module applicator assembly independent air

E 2015 Nordson Corporation Part 1124393_01


52 MiniBlue II Pneumatic Applicators

Single Wide and Multi Module Applicator Assembly (contd)

17

16

18
15
14
13 11

12

10

4
2 5

3
1 6
7
8

Figure 24: Multi module Best Choice replacement applicator assembly continuous air

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 53

Replacement Modules
Part Description
1095703 MODULE,MINIBLUE II BALL AND SEAT
1121479 MODULE, MINIBLUE II SUREBEAD .20 (.008) PURPLE
1121480 MODULE, MINIBLUE II SUREBEAD .31 (.012) GREEN
1121481 MODULE, MINIBLUE II SUREBEAD .41 (.016) ORANGE
1121482 MODULE, MINIBLUE II SUREBEAD .51 (.020) BEIGE
1121483 MODULE, MINIBLUE II SUREBEAD .81 (.032) GOLD
1121484 MODULE, MINIBLUE II SUREBEAD 1.0 (.040) TURQUOISE
1120093 KIT,MODULE BLANK, MINIBLUE II

Cordsets
Cordsets include RTDs.
Part Description Note
1124023 CORDSET, SLIM, MINIBLUE II A
1103014 CORDSET, MINIBLUE II B
1124021 CORDSET, MINIBLUE II, SIDE-MOUNT C
1103908 CORDSET, MINIBLUE II, WATER WASH B
1103015 CORDSET, MINIBLUE II, SLIM, WATER WASH A
1121501 KIT, CORDSET, APPLICATOR, FREEDOM A,B
1123116 KIT, CORDSET, APPLICATOR, FREEDOM, WW B
1123115 KIT, CORDSET, APPLICATOR, FREEDOM, WW, SLIM A
NOTE A: Used With Slimline Applicators.
B: Used With Standard Applicators, except side-mounted cordsets.
C: Used with standard applicators, with side-mounted cordsets.

E 2015 Nordson Corporation Part 1124393_01


54 MiniBlue II Pneumatic Applicators

Solenoid and Accessories

Solenoids
Part
Description Where Used Notes
Number
Used for single module
Nordson
SINGLE-MODULE applicators and
recommended
1095800 SOLENOID, SATURN independent actuation
solenoid for standard
SP (M5 PORTS) for multi-module
stitching applications
applicators
Used for single module Nordson waterwash
SINGLE-MODULE
applicators and solenoid
SOLENOID, SATURN
1124235 independent actuation recommended for
SP, WATERWASH
for multi-module standard stitching
(M5 PORTS)
applicators applications
High Performance
Used for single module solenoid,
SINGLE-MODULE applicators and recommended for
1123910 SOLENOID, P1 independent actuation applications that
(M5 PORTS) for multi-module demand the highest
applicators. level of precision and
repeatability
Used for single module
Recommended
SINGLE-MODULE applicators and
where Compact
771458 SOLENOID, SD MINI independent actuation
profile is of the
(M5 PORTS) for multi-module
highest importance
applicators
MULTI-MODULE
High flow SP not
SOLENOID, SATURN Used for common and
1120826 recommended for
SP (1/8 IN. NPT programmed actuation
stitching applications
PORTS)
MULTI-MODULE High flow SP for
SOLENOID, SATURN Used for common and waterwash, not
1124238
SP WATERWASH (1/8 programmed actuation recommended for
IN. NPT PORTS) stitching applications
SOLENOID, SATURN, Available as a
Used for common and
1069020 SG, 24 VDC, REV. replacement only for
programmed actuation
FUNCTION legacy applicators

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 55

Solenoid Cabling
Part
Description Where Used Notes
Number
CABLE ASSY,
1100687 SOLENOID, M8,
3-WIRE, 5 M
CABLE ASSY,
1100688 SOLENOID, 90 DEG,
M8, 3-WIRE, 5 M
CABLE ASSY,
P1 with cable, SD and
1100958 SOLENOID, M8,
SP
3-WIRE, 10 M
CABLE ASSY,
1100959 SOLENOID, 90 DEG,
M8, 3-WIRE, 10 M
Connects one
1121990 KIT, CABLE, SPLITTER extension cable to 2
solenoids
CABLE ASSY, P1, Limits current to 2A
1123970 SUPPRESSED, 2 PIN Used with P1 only maximum. Connects
SOCKET TO M8 to STD M8

E 2015 Nordson Corporation Part 1124393_01


56 MiniBlue II Pneumatic Applicators

Solenoid Hard Tubing Replacements Kits


Part
Description Where Used Kit Contents
Number
Independent Air Kits
Slim and MBII BCA
KIT, SOL TUBING, Contains 2 of
1123003 retrofit applicators with
MB2, M5 X 48 1098835 and O-rings
IA
KIT, SOL TUBING, MBII Wide applicators Contains 2 of
1123004
MB2, M5 X 39 with IA 1099274 and O-rings
KIT, SOL TUBING, MBII BCS retrofit Contains 2 of
1123005
MB2, M5 X 75 applicators with IA 1120909 and O-rings
Independent Air Kits
Wide body MBII
KIT, SOL TUBING,
applicator with common Necessary hard
1123672 MB2, WIDE W/CA/PA
or programmed air and tubing and fittings
SG
SG solenoid
Wide body MBII
KIT, SOL TUBING,
applicator with common Necessary hard
1123673 MB2, WIDE W/CA/PA
or programmed air and tubing and fittings
SP
SP solenoid
MBII BCA/BCS retrofit
KIT, SOL TUBING,
applicator with common Necessary hard
1123674 MB2, BCA/BCS
or programmed air and tubing and fittings
W/CA/PA SP
SP solenoid
MBII BCS retrofit
KIT, SOL TUBING, applicator (only fits 2
Necessary hard
1123675 MB2, BCS W/CA/PA SP module, 22mm pitch,
tubing and fittings
SPECIAL w/LB or RB cordset
position)

Solenoid Optional Flexible Tubing Connection Kits


Part
Description Where Used Kit Contents
Number
Straight fittings + 90
IA MBII with SP and SD banjo fittings + short
KIT,FLEX TUBING,MB2
735375 solenoids (incl straight applicator insert
IA, SP AND SD
and 90 deg fittings) tubes + tubing +
springs
KIT, FLEX TUBING, Pre-assembled, 1/8
CA/PA MBII with SP MM
735140 MB2 W/CA/PA SP NPT + tubing
and SG solenoids
MULTI AND SG +spring
Note: If longer tubing is needed, order by meter, 252277.

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 57

Solenoid Accessories and Spare Parts


Part
Description Where Used Kit Contents
Number
P1, SP, SP Waterwash,
375291 O-RING
and SD with M5 ports
734262 MUFFLER, M5 SD
MUFFLER, 1/8 IN. NPT,
1100452 SP
PLASTIC, COMPACT
MUFFLER, 1/8 IN. NPT,
1058058 SG
POLYETHYLENE
MUFFLER Used when adhesive
1106321 RESTRICTOR SP viscosity is below
SERVICE KIT SP 700 cps
Used when reduced
1082500 MUFFLER, R1/8 SP SP noise is required
(<85 dB)
APPLICATOR
SOLENOID FIELD
1106320 SP and SD
WIREABLE M8
FEMALE CONNECTOR
KIT, REPLACEMENT
10 pieces - Solenoid
1123073 ELECTRICAL SP
M8 connectors
CONNECT
1065791 MUFFLER, M7 P1
7507003 FITTING, M7 X6 TUBE P1
WATERWASH
Exhaust relocation
1124325 SOLENOID SP Waterwash
hardware
ACCESSORY KIT

E 2015 Nordson Corporation Part 1124393_01


58 MiniBlue II Pneumatic Applicators

Covers and Gaskets


Covers and gaskets apply to single wide, multi-module and retrofit applicators. Items must
meet all of the conditions specified in order to be used on the applicator.

Item Part Description Qty Note


7 1098838 GASKET, MINIBLUE MULTI 1
B, C, H
8 1098836 COVER, MINIBLUE MULTI, LB, RB 1
7 1098838 GASKET, MINIBLUE MULTI 1 B, C, G
8 1103762 COVER,MINIELITE MULTI, LS, RS 1
7 1120809 GASKET, MB2/BC, AOSC, SINGLE 2 A, D
8 1120661 COVER, MB2/BC, AOSC, SINGLE 2
7 1120906 GASKET, MB2/BC, AOAC, SINGLE 2 A, E
8 1120900 COVER, MB2/BC, AOAC, SINGLE 2
7 1120907 GASKET, MB2/BC, AOSC, MULTI 2 B, D, H
8 1120902 COVER, MB2/BC, AOSC, RB/LB, MULTI I, J
7 1120907 GASKET, MB2/BC, AOSC, MULTI 2 B, D, G
8 1120903 COVER, MB2/BC, AOSC, RS/LS, MULTI 1
7 1120908 GASKET, MB2/BC, AOAC, MULTI 2 B, E, H
8 1120904 COVER, MB2/BC, AOAC, RB/LB, MULTI I, J
7 1120908 GASKET, MB2/BC, AOAC, MULTI 2 B, E, G
8 1120905 COVER, MB2/BC, AOAC, RS/LS, MULTI 1
NOTE A: Used on Single Module Applicators
B: Used on Multi-Module Applicators
C: Used on "000" Manifold Style
D: Used on Expansion Spring-Close Manifold Style
E: Used on Expansion Air Close Manifold Style
F: Used For Water Wash Applications
G: Used For "LS or RS" Cordset Locations
H: Used For "LB or RB" Cordset Locations
I: If Cordset Position is "LS or RS" then Quantity is 1
J: If Cordset Position is "LB or RB" then Quantity is 2

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 59

Non SlimLine Mounting

Item Part Description Qty Note


12 272400 INSULATOR, MOUNT 1 A
KIT, BRACKET, APPLICATOR
13 326508 1
MOUNTING, KBCGS
WASHER, FLT, M, NARROW, M8, STL,
14 2
ZN
15 WASHER, LK, M, SPT, M8, STL, ZN 2
16 SCR, HEX, CAP, M8X45, BL 1
16 SCR, HEX, CAP, M8X25, BL 1
12 733539 ISOLATOR, 3MM, MINIBLUE B, C, D
13 1026940 BRACKET E, F, G
14 WASHER, FLT, M, REG, M6, STL, ZN
15 WASHER, LK, M, SPT, M6, STL, ZN
16 SCR, SKT, M6X40, ZN
NOTE A: Only Used on Single Module Applicators with Expansion Air Close Manifold
Style
B: If Manifold Length is < 150mm then Quantity is 1
C: If Manifold Length is > 150mm and < 300 then Quantity is 2
D: If Manifold Length is > 300 then Quantity is 3
E: If Manifold Length is < 150mm then Quantity is 2
F: If Manifold Length is > 150mm and < 300 then Quantity is 4
G: If Manifold Length is > 300 then Quantity is 6

E 2015 Nordson Corporation Part 1124393_01


60 MiniBlue II Pneumatic Applicators

Hose Connectors and Filter Assemblies


Refer to Table 8 to select the appropriate filter mesh size based on the orifice diameter of the
nozzle being used. Refer to Table 9 for Saturn filter part numbers.

Figure 25: Saturn in-line filter and integrated filter

Table 8 Recommended Filter Mesh Size


If the Nozzle Orifice Diameter is... ...use a filter with a...

50 Mesh (.30 mm) Screen


(Red ring)

100 Mesh (.15 mm)


Screen (Gold ring)

200 Mesh (.07 mm)


Screen (Purple ring)

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 61

Table 9 Saturn In-line Filters and Filter Elements


Description Part
NO FITTING, 50 MESH 1120049
NO FITTING, 100 MESH 1120050
NO FITTING, 200 MESH 1120051
STRAIGHT FILTER, 0.30 MM (0.0156 IN.), 50 MESH 1007033
STRAIGHT FILTER, 0.15 MM (0.0059 IN.), 100 MESH 1007034
STRAIGHT FILTER, 0.07 MM (0.0029 IN.), 200 MESH 1007035
90_ FILTER, 0.30 MM (0.0156 IN., 50 MESH 1007230
90_ FILTER, 0.15 MM (0.0059 IN.), 100 MESH 1007231
90_ FILTER, 0.7 MM (0.0029 IN.), 200 MESH 1007232
45_ FILTER, 0.30 MM (0.0156 IN.), 50 MESH 1007233
45_ FILTER, 0.15 MM (0.0059 IN.), 100 MESH 1007234
45_ FILTER, 0.07 MM (0.0029 IN.), 200 MESH 1007235

Filter Kits

Replacement parts for the Saturn In-line filter.


Description 2-Piece 5-Piece
Kit Part Number Kit Part Number
KIT, FILTER, 50 MESH, SATURN IN-LINE 1007372 1007036
KIT, FILTER, 100 MESH, SATURN 1007373 1007037
IN-LINE
KIT, FILTER, 200 MESH, SATURN 1007374 1007038
IN-LINE

Replacement parts for the Saturn M14 Integrated applicator filter.


Description 2-Piece 5-Piece
Kit Part Number Kit Part Number
KIT, FILTER, 50 MESH, SATURN 1045502 1123661
INTEGRATED
KIT, FILTER, 100 MESH, SATURN 1045506 1123662
INTEGRATED
KIT, FILTER, 200 MESH, SATURN 1045520 1123663
INTEGRATED

E 2015 Nordson Corporation Part 1124393_01


62 MiniBlue II Pneumatic Applicators

Applicator-to-Hose Connectors
See Figure 26. applicator-to-hose connectors are installed between the applicator and hose
to ease hose routing and to help prevent bending or pinching of the hose.

2 3
1

4
Figure 26: Applicator-to-hose fittings
Item Part Description Note
1 972657 CONNECTOR, HOSE, WITH A
O-RING, STRAIGHT
2 274179 CONNECTOR, HOSE, WITH
O-RING, 45_
3 274180 CONNECTOR, HOSE, WITH
O-RING, 90_
4 945032 S O-RING, VITON, 3/8 IN. TUBE B
NOTE A: All applicators are shipped with this straight hose connector pre-installed on the
applicator.
B: This is the replacement O-ring for all hose connectors.

Insulating Cuffs
Insulating cuffs are used to insulate hose-to-applicator joints.
Part Description
273634 CUFF, INSULATING, 64 MM (2.5 IN.)
273635 CUFF, INSULATING, 50 MM (2.0 IN.)
274429 CUFF, INSULATING, 44 MM (1.75 IN.)

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 63

Standard Saturn Nozzles


Saturn precision nozzles have patented color-coded rings that provide easy identification of
nozzle orifice size. Refer to the Adhesives and Sealants Equipment Guide for a full listing of
available Saturn nozzles.

Engagement Length Ring


Orifice Diameter Ring

Orifice Diameter Engagement Length and Top Ring Color mm (in.)


and Bottom Ring 1.3 (.050) 1.9 (.075) 2.5 (.100) 3.8 (.150) 7.6 (.300)
Color mm (in.) Purple Brown Blue Green Black
.20 (.008) Purple 322008
.25 (.010) Blue 322010
.31 (.012) Green 322012 322112 322212 322312 322412
.36 (.014) Yellow 322014 322114 322314 322414
.41 (.016) Orange 322016 322116 322216 322416
.46 (.018) Red 322018 322118 332318 322418
.51 (.020) Beige 322020 322120
.53 (.021) Brown 322421
.61 (.024) Gray 322424
.71 (.028) Black 322428

E 2015 Nordson Corporation Part 1124393_01


64 MiniBlue II Pneumatic Applicators

MiniBlue II Sure Bead Nozzles


Part Description
1121473 KIT, NOZZLE, .008 (PURPLE)
1121474 KIT, NOZZLE, .012 (GREEN)
1121475 KIT, NOZZLE, .016 (ORANGE)
1121476 KIT, NOZZLE, .020 (BEIGE)
1121477 KIT, NOZZLE, .032 (GOLD)
1121478 KIT, NOZZLE, .040 (TURQUOISE)

Heaters
SlimLine Applicator
240 VAC Cartridge 200 VAC Cartridge
6mm Diameter Heater P/N Heater 6mm Diameter Heater Heater
Wattage P/N Wattage
734013 109 1061561 100

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 65

Standard MiniBlue II Applicator


Minimum Maximum 240 VAC Cartridge 200 VAC Cartridge
Applicator Applicator ⅜ in. Heater ⅜ in. Heater
Body Length Body Length Diameter Wattage Diameter Wattage
(mm) (mm) Heater P/N Heater P/N
40.0 52.9 938123 150 1070406 150
53.0 64.9 448841 200 1070401 200
65.0 75.9 250682 200 1070291 200
76.0 83.9 121662 250 1070294 250
84.0 94.9 139311 250 1070296 250
95.0 109.9 109387 250 1070293 250
110.0 118.9 938126 280 1070407 280
119.0 128.9 109327 300 1070292 300
129.0 140.9 710669 327 1070400 300
141.0 153.9 702409 300 1070299 300
154.0 172.9 149294 350 1070297 350
173.0 179.9 938127 380 1072628 380
180.0 198.9 135817 476 1070295 400
199.0 221.9 938132 440 1072629 440
222.0 242.9 860879 500 1070402 500
243.0 267.9 149299 550 1070298 550
268.0 290.9 938077 600 1070405 600
291.0 305.0 938067 600 1070404 600

Retro-Fit MiniBlue II Applicator


Minimum Maximum 240 VAC Cartridge 200 VAC Cartridge
Applicator Applicator ½ in./13mm Heater ½ in./13mm Heater
Body Length Body Length Diameter Wattage Diameter Wattage
(mm) (mm) Heater P/N Heater P/N
44.0 58.2 1054662 200 1054628 200
58.3 69.4 1054663 200 1054629 200
69.5 77.2 1054664 250 1054630 250
77.3 88.2 1054672 250 1054633 250
88.3 102.6 1054673 250 1054634 250
102.7 112.3 1054675 280 1054635 280
112.4 121.7 1054676 300 1054637 300
121.8 134.5 1055575 300 1054638 300
134.6 147.5 1055576 300 1054639 300
147.6 166.9 1054677 350 1054640 350
167.0 173.4 1054678 380 1054642 380
173.5 192.8 1054659 400 1054644 400
192.9 216.9 1054681 440 1054647 440
217.0 238.2 1054683 500 1054650 500
283.3 264.1 1054685 550 1054652 550
264.2 286.9 1054688 600 1054655 600
287.0 305.0 1054689 600 1054656 600

E 2015 Nordson Corporation Part 1124393_01


66 MiniBlue II Pneumatic Applicators

Thermal Insulating Applicator Covers


Part Description
1099297 COVER, FLEXIBLE, SLIMLINE
1099298 COVER, FLEXIBLE, SINGLE MODULE, WIDE
1103018 PLASTIC COVER KIT, SINGLE MODULE SLIM
1120818 COVER, FLEXIBLE, SINGLE MODULE, WIDE, BEST CHOICE SPRING
CLOSED RETRO-FIT
1121065 COVER, FLEXIBLE, SINGLE MODULE, WIDE, BEST CHOICE AIR
CLOSED RETRO-FIT

Extension Cables
Extension cables are used when a applicator has two cordsets and only one hose will be
used.
Part Description
108946 CABLE, EXTENSION, APPLICATOR TO MELTER, 4.9 M (16 FT)
728023 CABLE, EXTENSION, WATER-WASH APPLICATOR TO MELTER,
5.5 M (18 FT)
728093 CABLE, EXTENSION, WATER-WASH, 6.1 M (20 FT)
124992 CABLE, EXTENSION, APPLICATOR TO BULK MELTER, 4.3 M
(14 FT)

Part 1124393_01 E 2015 Nordson Corporation


MiniBluet II Pneumatic Applicators 67

Maintenance Accessories
Part Description
132426 DIAGNOSTIC DEVICE W/CABLE ASSY (hose/applicator)
1108372 LUBRICANT, O-RING, 4 OZ (FOR LUBRICATING O-RINGS)
1108371 LUBRICANT, NEVER-SEEZ, 8 OZ CAN
1120201 NEVER-SEEZ, 1 OZ
900290 NEAT'S FOOT OIL
901915 NOZZLE CLEANING KIT
331871 NUTDRIVER,5/32 (Tool, removal/installation, integrated
right-angle module nozzles)
231262 KIT, QUICK-DISCONNECT FITTING, 1/4 NPT (solenoids)
270755 TYPE R FLUID, 1.0 GAL
902514 GLOVES,SAFETY (Protective gloves)

Specifications
Parameter Specification
Operating temperature 204 _C (400 _F) maximum
Operating air pressure(1) 3.4-5.5 bar (50-80 psi)
Working hydraulic pressure 103 bar (1500 psi) maximum
Solenoid valves Nordson 24 VDC high temperature,
factory installed
Electrical service 240 VAC, 50/60 Hz; 200 VAC, 50/60 Hz
optional
(1) Recommended range. Dry, regulated non-lubricated air required for consistent applicator
operation.

E 2015 Nordson Corporation Part 1124393_01


68 MiniBlue II Pneumatic Applicators

Dimensions
Dimension drawings can be found on the emanuals.nordson.com website.

Part 1124393_01 E 2015 Nordson Corporation


MiniBlue II Applicator Configuration Code
To determine the configuration of a applicator, obtain its configuration code and refer to Table 10.
Table 10 Explanation of Applicator Configuration Code Positions
Code
Description Code Value
Position
Configuration Code

E 2015 Nordson Corporation


1 2 3 4 5 6 7 8 9 10 11 12

}
}
}
}
}
}
}
}

}
}
}
}

MB2 BEL 00 A CA T TS SP E4 1 000 000


1 Applicator model MiniBlue II
2 Module type BEL = MiniBlue II ball and seat 020 = .020 Surebead orifice nozzle
008 = .008 Surebead orifice nozzle 032 = .032 Surebead orifice nozzle
012 = .012 Surebead orifice nozzle 040 = .040 Surebead orifice nozzle
016 = .016 Surebead orifice nozzle
3 Number of modules 1-8, 00 = Slimline, all others wide modules
NOTE: All Slimline applicators will come with plastic covers installed.
4 Voltage A = 240 V
B = 200 V
5 Air supply CA = common air
configuration IA = independent air
PA = programmed air
6 Cordset type T = 3000/Blue Series F = Freedom Series cordset
W = Water wash D = Freedom Series water wash cordset
Continued...

Part 1124393_01
MiniBlue™ II Pneumatic Applicators 69
Code
Description Code Values
Position
7 Cordset position TS = Top Side
LS = Left Side

Part 1124393_01
RS = Right Side
LB = Left Back
RB = Right Back
8 Solenoid SP = Saturn Platinum
SD = MiniMac
P1 = P1
NOTE: The SG solenoid is available only for legacy applicators.
9 Hose connector angle E0 = 50-mesh straight
70 MiniBlue™ II Pneumatic Applicators

and mesh size E4 = 50-mesh 45-degree


E9 = 50-mesh 90-degree
F0 = 100-mesh straight
F4 = 100-mesh 45-degree
F9 = 100-mesh 90-degree
G0 = 200 mesh straight
G4 = 200 mesh 45-degree
G9 = 200 mesh 90-degree
10 Number of hydraulic 1
ports 3
5
11 Cover 000 = No Cover
010 = Soft Cover
12 Manifold style 000 = Standard MiniBlue
BCA = Mounts in same location as a Best Choice Air-Close applicator
BCS = Mounts in same location as a Best Choice Spring-Close applicator

E 2015 Nordson Corporation