Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

LEGAL NOTES

NOTES
1. ALL DIMENSIONS ARE IN MM UNLESS NOTED OTHERWISE ONLY WRITTEN DIMENSION
SHALL BE FOLLOWED. NO DIMENSION SHALL BE SCALED
2. THIS DRAWING IS APPLICABLE FOR ONLY PRECAST FT FLUME.
3. FOR LAYOUT OF FT FLUME DRAIN, FT FLUME DRAIN LAYOUT SHOULD BE REFERRED AT
EACH RESPECTIVE LOCATION.
4. WHERE FT FLUME DRAIN LIES IN FILLED UP OR LOOSE SOIL, SOIL BELOW THE DRAIN
SHALL BE WELL RAMMED.
5. LENGTH OF EACH SEGMENT OF PRECAST SHALL BE 2M.
6. ALL SEGMENTS OF PRECAST FT FLUME OF PARTICULAR SECTION ARE IDENTICAL.
TOTAL LENGTH OF FT FLUME DRAINS SHALL BE ADJUSTED AS PER LAYOUT AND CAST
IN SITU SHALL BE DONE AS REQUIRED AT THE ENDS AND INTERSECTIONS.
4 SD10x2 4 SD10x2 4 SD10x2 4 SD10x2 7. GRADE OF CONCRETE IS M-50 CONFIRM TO IS:456 LATEST EDITION
8. REINFORCEMENT BAR SHALL BE TMT BARS CONFIRMING TO IS 1786-GRADE
FE-500/FE-500D.
9. REINFORCEMENT SHALL BE BENT AND FIXED AT PLANT UNDER SPECIFIED CONDITIONS.
20.0000 20.0000 20.0000 20.0000 10. FOUNDING DEPTH SHALL BE DECIDED ON THE AVAILABLE SAFE BEARING CAPACITY
(10T/M²) AT FIELD.
11. CONCRETE EXPOSURE CLASSIFICATION IS MODERATE.
8 SD8×4 7 SD8x16 7 SD8x16 7 SD8x16
30.0000 30.0000 12. ALL JOINT ARE TO BE FILLED WITH 1:3 CEMENT MORTAR.
13. FOLLOWING CONCRETE COVER SHALL BE PROVIDED
4 SD10x2 4 SD10x2 4 SD10x2 4 SD10x2 a) BASE SLAB = 30mm
5 SD6×8 5 SD6×8 5 SD6×8 5 SD6×8 b) INNER SIDE WALL = 20mm
c) OUTER RIB = 30mm
10 SD10×12 10 SD10×12 10 SD10×12
LEGENDS
9 SD10×2 6 SD6×2 9 SD10×2 6 SD6×2 9 SD10×2 6 SD6×2 9 SD10×2 6 SD6×2
30.0000 30.0000 30.0000 30.0000 1 SD16 × 4
1 SD12×4 1 SD12×4 2 SD12×2 3 SD10×4
Nos. of Bar
- SECTION A-A - SECTION B-B - SECTION C-C - SECTION D-D
Diameter of Bar
- REINFORCEMENT DETAIL OF PRECAST FT FLUME
- REINFORCEMENT DETAIL OF PRECAST FT FLUME - REINFORCEMENT DETAIL OF PRECAST FT FLUME
- REINFORCEMENT DETAIL OF PRECAST FT FLUME Bar Marking
2000.0000
5 SD6×8 1 SD12×4 5 SD6×8 2 SD12×2
10 SD10×12
1 SD12×4
90.0000 90.0000 1 SD12×4
8 SD8×4
8 SD8×4
3 SD10×4
7 SD8×16 7 SD8×16 1040.0000
900.0000 900.0000
2 SD12×2
10 SD10×12
90.0000 90.0000 6 SD6×2 9 SD10×2
- SECTION F-F (BASE SLAB)
2000.0000 2000.0000 - REINFORCEMENT DETAIL OF PRECAST FT FLUME
- SECTION E-E (PLAN) - SECTION F-F (PLAN)
- REINFORCEMENT DETAIL OF PRECAST FT FLUME - REINFORCEMENT DETAIL OF PRECAST FT FLUME 6.0000 3.0000
16.0000 1100.0000
3.0000
100.0000
1100.0000x1000
D B C A SD12-6 SD6-8 PT
LID COVER 00 09.06.2020 ISSUED FOR APPROVAL
2000.0000 90 900.0000 90.0000 - DETAIL OF GROOVE - SECTIONAL VIEW
REV. DATE DESCRIPTION APPROVED
- - DETAILS OF LID COVER SIZE (1100mmx1000mm) RELEASE FOR
FOR PRELIMINARY FOR CONSTUCTION
FOR INFORMATION WITH DESIGN SUBMISSION
2000.0000
1100.0000 FOR REVIEW AS BUILT
E E
90.0000
CLIENT
900.0000 900.0000
995.0000 995.0000
MILAN ROAD BUILDTECH
138 66.0000
F F
PROJECT
900.0000 1000.0000
95.0000 95.0000
20.0000 PACKAGE MU-06
75.0000 PCC
Hanging hole
D B C A 200.0000 COMPACTED EARTH M12-55(PK) DESIGN BY
FUJI SILVERTECH CONCRETE PVT. LTD.
20MM THK 4TH FLOOR, HOUSE NO. 5,
LEVELING MORTAR 90.0000 MAGNET CORPORATE PARK,
NEAR SOLA FLYOVER, S.G. HIGHWAY,THALTEJ,
1040.0000 AHMEDABAD-380 054
- SIDE VIEW - SECTIONAL VIEW - PLAN VIEW - PLAN VIEW
Website : http://www.fujisilvertech.com
- DIMENSION DETAIL OF PRECAST FT FLUME - DIMENSION DETAIL OF PRECAST FT FLUME - DIMENSION DETAIL OF PRECAST FT FLUME - DETAILS OF LID COVER SIZE (1100mmx1000mm) DRAWING TITLE:
TYPICAL DIMENSION AND REINFORCEMENT
DETAIL OF FT FLUME
TABLE 1: REINFORCEMENT OF FT FLUME SIZE (900mmx900mm) (Size = FT FLUME 900x900)
SIZE(mm) REINFORCEMENT
DRAWN: ATUL CHECKED: SK
WxH L 1 2 3 4 5 6 7 8 9 10
DATE: 09.06.2020 APPROVED: PT
600x 900 2000 SD12-4 SD12-2 SD10-4 SD10-4 SD6-8 SD6-2 SD8-16 SD8-4 SD10-2 SD10-12
SCALE:
NTS
DRAWING NO. Rev. No.
FSC-MU06-FTF-DR-SEC-01 00