Control Unit For Two Actuators: Use and Installation Manual
Control Unit For Two Actuators: Use and Installation Manual
Control Unit For Two Actuators: Use and Installation Manual
CONTROL UNIT
GB INSTRUCTIONS ON ASSEMBLY, USE
AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
Summary
4 ENGINEERING DATA 12
9
italiano e inglese 25-11-2002 9:37 Pagina 10
CONTROL UNIT
GB INSTRUCTIONS ON ASSEMBLY, USE
AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
Fig. 1
L1(3)
230V~
L2(2) CONTROL
N(1)
L1(3)
L1(3)
230V~ L2(2) ACTUATOR 2
N(1)
TERRA
Fig. 2
10
italiano e inglese 25-11-2002 9:37 Pagina 11
CONTROL UNIT
GB INSTRUCTIONS ON ASSEMBLY, USE
AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
11
italiano e inglese 25-11-2002 9:37 Pagina 12
CONTROL UNIT
GB INSTRUCTIONS ON ASSEMBLY, USE
AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
Restrict use of the control unit to qualified passes after a lock occurs following an opening or
personnel; do not expose the control unit closing command. The maximum time is the time
to splashes of water when cleaning the (1.5S) that passes during the dynamic phase from
room. the moment of the two actuators stops absorbing
current until when the other one is stopped.
Do not allow children to play with the The actuators’ lock occurs by switching off the
control unit; it is necessary to remove all power supply voltage on both actuators.
sources of power supply with an
appropriate knife switch prior to 3.2 Electrical features:
performing maintenance on the control The control unit is provided with a power supply
unit or on the actuators connected to it. input (fig. 2, CONTROL) at 230V~±6% - 50Hz. And
two relay outputs with the same electrical
specifications (fig. 2, ACTUATOR 1 and 2) for
In the event of failures or damage to the equipment, connecting the two actuators.
contact specialised personnel. Do not use the device Suitable devices (fuses) are contemplated in the
until it has been repaired. case of overcurrent.
3 DESCRIPTION OF THE INSTRUMENT 3.3 Mechanical features:
The electric “parts” are contained inside an
88x128x58 mm (fig.1_A) connector block with an
3.1 Operation features: IP56 degree of tightness. Three cable clamps with
The synchronisation control unit for two actuators is relative nuts (fig. 1_B) and 4 sealant plugs for
able to control all Mingardi Magnetic line actuators possible fastening screws (fig. 1_C) are supplied
provided with asynchronous motors running at together with the block.
230V 50Hz.
The actuators connected to the control unit, which 4 ENGINEERING DATA
must be the same, will both lock with a spatial
displacement proportional to approximately 1.5S if
one of the two stops absorbing current. Once the Dimensions: 88x128x58 mm.
block occurs, it is impossible to make operations in
the direction in which the lock occurred except for a Degree of tightness: IP56.
first proportional attempt at about 0.1S. On the
other hand, it is possible to operate the actuators in Working temperature: from -10 to 50 C°.
the direction opposite the lock.
There is then a minimum time and a maximum Maximum working humidity: 60%.
time. The minimum time is the time (0.1S) that
12
italiano e inglese 25-11-2002 9:37 Pagina 13
CONTROL UNIT
INSTRUCTIONS ON ASSEMBLY, USE
GB AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
5 CONTROL UNIT
Power supply: 230V~±6% - 50Hz. ASSEMBLY / INSTALLATION
Fields of application:
Only qualified installers can carry out
Product intended for use in indoor environments for
installation.
controlling actuators used for the electric remote
The control unit must be assembled and wired
opening/closing of top-hung windows, skylights and
louvre windows in public, private and industrial only by specialised personnel who have been
properly trained and who are familiar with
buildings.
problems of automatic window opening and
closing systems, technical reference
Warning!
Use only actuators provided with standards and safety standards.
temperature protection.
Warning!
Incorrect installation may make the
Identification data on the control unit rating control unit dangerous! Follow all the
instructions set out below.
plate
Checks
Before installing, check that:
Mingardi Magnetic Srl • The electric cables connected to the device
have the proper section.
A Mod. 2020201100 Nr: N000001 • The electric power supply systems are in
B Input:230V 50Hz 4A compliance with the standards in force in the
Output:230V~ country where it is installed.
C
• All of the power supply sources are switched
D IP56
off when making interventions on the control
unit or on the actuators connected to it.
Legend: • Check that the wires are properly connected
A: Model and serial number Compliant with to the control unit.
B: Voltage, frequency and the 73/23/EEC • Check that the power supply voltage is the
Maximum input current and 89/336EEC same as that shown on the control unit’s rating
C: Maximum output voltage plate.
directives
D: Degree of protection
Fig. 3
13
italiano e inglese 25-11-2002 9:37 Pagina 14
CONTROL UNIT
INSTRUCTIONS ON ASSEMBLY, USE
GB AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
14
14
italiano e inglese 25-11-2002 9:37 Pagina 15
CONTROL UNIT
INSTRUCTIONS ON ASSEMBLY, USE
GB AND INSTALLATION
FOR TWO ACTUATORS
230 V a.c.
Warning!
The earth wires must be connected to
the relative terminal board so that they
are always the last to break in the case of excess
mechanical stress.
15
15
italiano e inglese 25-11-2002 9:37 Pagina 8
NOTE
MINGARDI S.r.l.
Via C. Bassi 7/A
40015 GALLIERA (BO) Italy
Tel. +39 (051) 6672711
Fax +39 (051) 6672790
2700171