<row>
<column name="Notes">all valves operated</column>
<column name="MaintLogID1">BRMR35020001</column>
</row>
<row>
<column name="Notes">One wolflite charger at Tm2 found loose. New
securing screws fitted.
All satisfactory</column>
<column name="MaintLogID1">BRMR35020002</column>
</row>
<row>
<column name="Notes">Two new harnesses placed in ER.
No.1 0.65/1.15
No.2 0.6/1.2
No.3 0.6/1.2
No.4 0.65/1.15
No.5 0.65/1.15
No.7 0.65/1.15
No.8 0.6/1.15
No.9 0.6/1.15</column>
<column name="MaintLogID1">BRMR35020062</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020063</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020064</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020065</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020066</column>
</row>
<row>
<column name="Notes">Motor winding insulation to earth,
100+megohms on both High and Low speed windings, also on the heater.
All contacts in very good condition.
A connections in good condition, no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020067</column>
</row>
<row>
<column name="Notes">All alarms and trips operated
satisfactory</column>
<column name="MaintLogID1">BRMR35020068</column>
</row>
<row>
<column name="Notes">All alarms and trips operated
satisfactory</column>
<column name="MaintLogID1">BRMR35020069</column>
</row>
<row>
<column name="Notes">grease changed and coupling inspected</column>
<column name="MaintLogID1">BRMR35020070</column>
</row>
<row>
<column name="Notes">grease renewed coupling inspected</column>
<column name="MaintLogID1">BRMR35020071</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020072</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020073</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020074</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020075</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020076</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020077</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020078</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020079</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020080</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020081</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020082</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020083</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020084</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020085</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020086</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020087</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020088</column>
</row>
<row>
<column name="Notes">Alarm test satisfactory.
</column>
<column name="MaintLogID1">BRMR35020089</column>
</row>
<row>
<column name="Notes">All external lights satisfactory, insulation
readings satisfactory.
</column>
<column name="MaintLogID1">BRMR35020090</column>
</row>
<row>
<column name="Notes">Fire Heads tested as per routes 11 and 12 -
all satisfactory.
</column>
<column name="MaintLogID1">BRMR35020091</column>
</row>
<row>
<column name="Notes">Alarm test satisfactory.
</column>
<column name="MaintLogID1">BRMR35020092</column>
</row>
<row>
<column name="Notes">Alarm test satisfactory.
</column>
<column name="MaintLogID1">BRMR35020093</column>
</row>
<row>
<column name="Notes">All tests being carried out and recorded in
the GMDSS Log book.
</column>
<column name="MaintLogID1">BRMR35020094</column>
</row>
<row>
<column name="Notes">Indicators showing correct readings, linkages
appear in good condition.
</column>
<column name="MaintLogID1">BRMR35020095</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
</column>
<column name="MaintLogID1">BRMR35020096</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
Running hours: 20205.7</column>
<column name="MaintLogID1">BRMR35020097</column>
</row>
<row>
<column name="Notes">Cooler isolated and water drained.
Inspection covers removed.
Both sides tube ends checked - ok, no damage or wear found.
All covers put back, cooler vented and tested for leaks.
All satisfactory and cooler back in service.
Running hours: 20205.7
</column>
<column name="MaintLogID1">BRMR35020098</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
Small leak in workshop ELSA - gauge o-ring replaced and bottle topped up.
</column>
<column name="MaintLogID1">BRMR35020099</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020100</column>
</row>
<row>
<column name="Notes">Both batteries renewed February 2006.
Battery type - Yuasa NP4-12 12V 4Ah, RS code 198-8068.
The batteries to be renewed in February 2008.
Two piece required.
</column>
<column name="MaintLogID1">BRMR35020101</column>
</row>
<row>
<column name="Notes">Cabinets checked and no signs of burning, all
connectotrs tight.
</column>
<column name="MaintLogID1">BRMR35020102</column>
</row>
<row>
<column name="Notes">Cabinets checked and no signs of burning, all
connectotrs tight.
Earth bonding straps in good condiyion.
Shaft earthing brushes in good condition and slip ring cleaned regularly.
</column>
<column name="MaintLogID1">BRMR35020103</column>
</row>
<row>
<column name="Notes">Shaft earthing brushes in good condition and
slip ring cleaned regularly.
Earth bonding cables in good condition.
</column>
<column name="MaintLogID1">BRMR35020104</column>
</row>
<row>
<column name="Notes">System operating correctly.
</column>
<column name="MaintLogID1">BRMR35020105</column>
</row>
<row>
<column name="Notes">Battery tested on load for 2 hours.
Battery voltage before test 26.21 Volts.
Battery voltage after test 24.87 Volts.
Current 3 Amps.
</column>
<column name="MaintLogID1">BRMR35020106</column>
</row>
<row>
<column name="Notes">Emergency Generator Battery Baknk,
Resdings
1 - 12.65V
2 - 12.65V
3 - 12.67V
4 - 12.63 V.
</column>
<column name="MaintLogID1">BRMR35020107</column>
</row>
<row>
<column name="Notes">Starboard Lifeboat Battery Voltages
Off Load On Load
13.09V 11.89V
13.20V 11.90V
</column>
<column name="MaintLogID1">BRMR35020108</column>
</row>
<row>
<column name="Notes">Rescue Boat Battery Voltages
Off Load On Load
Fwd 13.31V 11.96V
Aft 13.31V 11.96V
</column>
<column name="MaintLogID1">BRMR35020109</column>
</row>
<row>
<column name="Notes">Port Lifeboat Battery Voltages
Off Load On Load
Fwd 13.49V 11.97V
Aft 13.28V 11.91V
</column>
<column name="MaintLogID1">BRMR35020110</column>
</row>
<row>
<column name="Notes">EPIRB Tests satisfactory and recorded in the
GMDSS Log book.
Battery and Hydrostatic release due for renewal next January February 2007.
</column>
<column name="MaintLogID1">BRMR35020111</column>
</row>
<row>
<column name="Notes">All fire door operating correctly.
</column>
<column name="MaintLogID1">BRMR35020112</column>
</row>
<row>
<column name="Notes">All laundry equipment checked and all
satisfactory.
</column>
<column name="MaintLogID1">BRMR35020113</column>
</row>
<row>
<column name="Notes">The breaker is tripping continually.
Checked the wiring and found that one of the Star / Delta changeover relays
has welded contacts,
so shorting the 440v input. Replaced the relay with ship's spare.
Will find another relay and replace the other unit in the Range as this is
showing signs of heating.
Spare used, Contactor, 440V coil, 4 by NO contacts,
8.1211.01.012 Used 1, rob nil.
</column>
<column name="MaintLogID1">BRMR35020114</column>
</row>
<row>
<column name="Notes">Refer manual. Air Products, PM-18 (PM-11).
On both generators, when the Oxygen High alarm activates the 'on
line' solenoid valve XY-2A (XY-2B)
closes, it should remain open to allow the system to correct itself.
The Oxygen High High alarm activates the 'dump' solenoid valve
XY-3A (XY-3B) should open.
Also.
On both generators, when the Dew Point High alarm activates the 'on
line' solenoid valve XY-2A (XY-2B)
closes, it should remain open to allow the system to correct itself.
The Dew Point High High alarm activates the 'dump' solenoid valve
XY-3A (XY-3B) should open.
When the following modification is carried out all the present alarms are
active,
i.e. local panel and IAS system.
Display Unit
Kelvin Hughes NIS 2002 MK2 AIS System
P/N SA7001-000-253
S/N 106105
24V DC 0.3A
R4 Transponder
Kelvin Hughes R4-AIS Shipborne Class A Transponder
P/N SA7001-000-252
S/N 12378
24V DC 3A
IC: 4660A-R4AIS A
FCC ID QWZR4-AIS
USCG No. 165.155.80
</column>
<column name="MaintLogID1">BRMR35020122</column>
</row>
<row>
<column name="Notes">Open indicitor proximity switch replaced with
spare.
Used: 1 x inductive proximity switch, XSA NO 1122, 7A 12v - 1.5mm
ROB: 3</column>
<column name="MaintLogID1">BRMR35020123</column>
</row>
<row>
<column name="Notes">Coupling inspected Grease changed no defects
observed</column>
<column name="MaintLogID1">BRMR35020124</column>
</row>
<row>
<column name="Notes">Coupling inspected new grease applied no
defects found</column>
<column name="MaintLogID1">BRMR35020125</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020126</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020127</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020128</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020129</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020130</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020131</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020132</column>
</row>
<row>
<column name="Notes">As per weekly routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020133</column>
</row>
<row>
<column name="Notes">Equiptment inspected no defects
observed</column>
<column name="MaintLogID1">BRMR35020134</column>
</row>
<row>
<column name="Notes">As per PM</column>
<column name="MaintLogID1">BRMR35020135</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020136</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020137</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020138</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020139</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020140</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020141</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020142</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020143</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020144</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35020145</column>
</row>
<row>
<column name="Notes">Motor windings insulation to earth
100+Megohms.
No signs of burning, all connections secure, contactors in good
condition.
</column>
<column name="MaintLogID1">BRMR35020146</column>
</row>
<row>
<column name="Notes">As per PM. No defects observed.</column>
<column name="MaintLogID1">BRMR35020147</column>
</row>
<row>
<column name="Notes">As per PM. All in good working
order.</column>
<column name="MaintLogID1">BRMR35020148</column>
</row>
<row>
<column name="Notes">All 8 risers checked, NIL water found</column>
<column name="MaintLogID1">BRMR35020149</column>
</row>
<row>
<column name="Notes">All alrms tested</column>
<column name="MaintLogID1">BRMR35020150</column>
</row>
<row>
<column name="Notes">Alarms tested</column>
<column name="MaintLogID1">BRMR35020151</column>
</row>
<row>
<column name="Notes">Tested as per rota</column>
<column name="MaintLogID1">BRMR35020152</column>
</row>
<row>
<column name="Notes">Tested as per rota</column>
<column name="MaintLogID1">BRMR35020153</column>
</row>
<row>
<column name="Notes">All valves operated</column>
<column name="MaintLogID1">BRMR35020154</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All alarms operational.
Also 1/4" ball valve fitted on CFW press. switch for bleeding press.
and testing alarm.
All tested and no leaks found.</column>
<column name="MaintLogID1">BRMR35020155</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All probes checked, cleaned and tested.
All seals in good condition.</column>
<column name="MaintLogID1">BRMR35020156</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All alarms operational.</column>
<column name="MaintLogID1">BRMR35020157</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All alarms operational.</column>
<column name="MaintLogID1">BRMR35020158</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
</column>
<column name="MaintLogID1">BRMR35020159</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020160</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020161</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020162</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020163</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020164</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020165</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020166</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020167</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020168</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
No.1 pump in use this week.</column>
<column name="MaintLogID1">BRMR35020169</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
No.2 pump on st-by this week.</column>
<column name="MaintLogID1">BRMR35020170</column>
</row>
<row>
<column name="Notes">All fittings on valves checked.</column>
<column name="MaintLogID1">BRMR35020171</column>
</row>
<row>
<column name="Notes">All fittings on valves checked.</column>
<column name="MaintLogID1">BRMR35020172</column>
</row>
<row>
<column name="Notes">Calabration carried out as per instruction
book</column>
<column name="MaintLogID1">BRMR35020173</column>
</row>
<row>
<column name="Notes">Calabration carried out as per instruction
book</column>
<column name="MaintLogID1">BRMR35020174</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020175</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020176</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020177</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020178</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020179</column>
</row>
<row>
<column name="Notes">All fastenings tight, No abnormal noise or
vibration, All points greased.</column>
<column name="MaintLogID1">BRMR35020180</column>
</row>
<row>
<column name="Notes">As per PM, Coupling inspected and found to be
in good condition, No excessive movement or vibration, All points greased.
see below
Please could you ensure that the vessel is supplied with a operational
unit and printer prior to removing the old unit. The vessel must not be
left without any alcohmeter on board.
-----Original Message-----
From: British Merchant - Master [mailto:master.merchant@bpfleet.com]
Sent: 07 August 2006 16:51
To: Clifton, Andrew
Cc: BPS - Merchant; Parker, Mike (BP Shipping); British Merchant - Chief
Engineer
Subject: British Merchant - Lion Alcohmeter - ABLE PRINTER - serial no
of the SD 400P
We found that the Printer aboard is the Axiohm type. From the
correspondence below I can see the alcometer software is not compatible
with the newer able printer.
We have been requested to land the older alchometer ashore for updating.
Best Regards
Nicholas Bourke
Master
British Merchant
Email: master.merchant@bpfleet.com
Sat-B tel +870 323563710
Vsat tel +44 1932 44 3241 (Office)
+44 1932 44 3240 (Bridge)
Mobile +44 7881 841949
-----
From: British Merchant - Chief Engineer
Date: Mon, 7 Aug 2006 14:14 +0000 Msg: VQIB9-106137
Subject: Fw: MER/06/178: ABLE PRINTER - serial no of the SD 400P
To: British Merchant - Master
Nick,
Best regards
Sunil Mohotti
Chief Engineer
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: Jaffray, Mark
Date: Mon, 7 Aug 2006 11:20 +0000 Msg: AMOS-59284694
Subject: FW: MER/06/178: ABLE PRINTER - serial no of the SD 400P
To: British Merchant - Chief Engineer
Cc: BPS - Merchant
Hi Sunil
Please see message below from Lion Labs re the above order.
-----Original Message-----
From: Day, Phil
Sent: 04 August 2006 10:48
To: Jaffray, Mark
Subject: FW: MER/06/178: ABLE PRINTER - serial no of the SD 400P
Importance: High
Hi Mark,
-----Original Message-----
From: Lorraine Goodall [mailto:lgoodall@lionlaboratories.com]
Sent: 03 August 2006 09:56
To: Day, Phil
Cc: Debbie Wheeler
Subject: RE: MER/06/178: ABLE PRINTER - serial no of the SD 400P
Phil
Thank you for that information. Having therefore checked our records it
would appear that this instrument is not configured to used the able
printer. The original instrument was purchased in March 1999 and
configured to be used with another printer (Datac), which is no longer
available. Therefore you need to get the ship to return the instrument
to our Service Dept here at Lion, where we will be able to re-configure
the instrument (FOC) and fully test the instrument with the able
printer, then send printer and instrument back together.
Hope this is not too much trouble, but as you will appreciate we can't
send out a printer which will not work with the existing inst.
Please advise if this is OK, and when the instrument will be likely to
be returned to us.
Regards
Lorraine
-----Original Message-----
From: Day, Phil [mailto:Phil.Day@uk.bp.com]
Sent: 03 August 2006 07:46
To: Lorraine Goodall
Subject: FW: MER/06/178: ABLE PRINTER - serial no of the SD 400P
Hi Lorraine,
Re: Order 035/16/08179 - British Merchant - Please see Serial Number of
the SD-400 as requested below.
Alco SD400
s/n. 023738D
Best Regards,
Phil Day
Fleet Procurement Team
BP Shipping Ltd.
Tel : +44 1932 771526
Fax: +44 1932 771690
E-mail: phil.day@uk.bp.com
-----Original Message-----
From: Lorraine Goodall [mailto:lgoodall@lionlaboratories.com]
Sent: 02 August 2006 15:13
To: Day, Phil
Subject: Order 035/16/08179 - British Merchant
Phil
Regards
Lorraine
Sales Dept
</column>
<column name="MaintLogID1">BRMR35020187</column>
</row>
<row>
<column name="Notes">Unit tested as per PM routine. All alarms
sounded correctly in cabins and spaces.</column>
<column name="MaintLogID1">BRMR35020188</column>
</row>
<row>
<column name="Notes">As per PM, Belts inspected and found to be in
good condition as replaced 25/07.
Holding down bolts tight, Motor and fan cleaned.
Mtr load: 8 Amps </column>
<column name="MaintLogID1">BRMR35020189</column>
</row>
<row>
<column name="Notes">As per PM, Belts inspected and found to be
cracked, No spares onboard so not relpaced. Belts on order.
Holding down bolts tight, Motor and fan cleaned.
Motor load: 4.6 Amps.</column>
<column name="MaintLogID1">BRMR35020190</column>
</row>
<row>
<column name="Notes">Bearing not replaced as no excessive vibration
or movement. Belts replaced 25/07 due to failure.
Motor load: 8 Amps</column>
<column name="MaintLogID1">BRMR35020191</column>
</row>
<row>
<column name="Notes">Bearing not replaced as no excessive vibration
or movement. Belts not replaced as no spares onboard.
Motor load: 4.6 Amps </column>
<column name="MaintLogID1">BRMR35020192</column>
</row>
<row>
<column name="Notes">Impeller and motor fins cleaned, No excessive
movement on impeller or bearings. As fastenings and fittings tight. No
abnormal
noise or vibration from bearings. All points greased.</column>
<column name="MaintLogID1">BRMR35020193</column>
</row>
<row>
<column name="Notes">Impeller and motor fins cleaned, No excessive
movement on impeller or bearings. As fastenings and fittings tight. No
abnormal
noise or vibration from bearings. All points greased.</column>
<column name="MaintLogID1">BRMR35020194</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020195</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020196</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020197</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020198</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020199</column>
</row>
<row>
<column name="Notes">Motor Windings to earth insulation
100+Megohms.
All contactors in good condition.
Connections secure and no signs of burning.
</column>
<column name="MaintLogID1">BRMR35020200</column>
</row>
<row>
<column name="Notes">See Battery Log for voltage readings.
After 2 hours on load Battery 24.88 Volts.
</column>
<column name="MaintLogID1">BRMR35020201</column>
</row>
<row>
<column name="Notes">307 307 293 295
315 315 298 298 230 230
230 230 103 99.7 102 97.2 242 242
99 99 All batteries
in good condition.
</column>
<column name="MaintLogID1">BRMR35020202</column>
</row>
<row>
<column name="Notes">compressors changed over. no.3 is now
priority, no.2 is 2nd priority, no.1 is 3rd priority.solenoid valves
on all compressors cleaned, water filter valves cleaned. </column>
<column name="MaintLogID1">BRMR35020203</column>
</row>
<row>
<column name="Notes">compressors changed over no.1 is now lead,
no.2 is lag, all running satisfactory. </column>
<column name="MaintLogID1">BRMR35020204</column>
</row>
<row>
<column name="Notes">oil content monitor tested as per pm</column>
<column name="MaintLogID1">BRMR35020205</column>
</row>
<row>
<column name="Notes">compressors c/o no.1 is now lead, no.2 is
lag</column>
<column name="MaintLogID1">BRMR35020206</column>
</row>
<row>
<column name="Notes">all flaps operated using their local
open/close valve, operation all satisfactory </column>
<column name="MaintLogID1">BRMR35020207</column>
</row>
<row>
<column name="Notes">drains oil content monitor tested as per
pm.all satisfactory</column>
<column name="MaintLogID1">BRMR35020208</column>
</row>
<row>
<column name="Notes">all idle machinery rotated by hand.</column>
<column name="MaintLogID1">BRMR35020209</column>
</row>
<row>
<column name="Notes">compressors c/o no.3 is now priority, no.2 is
standby and 1 is priority no.3</column>
<column name="MaintLogID1">BRMR35020210</column>
</row>
<row>
<column name="Notes">control air driers c/o no leaks observed all
satisfactory, no.1 is now in use.</column>
<column name="MaintLogID1">BRMR35020211</column>
</row>
<row>
<column name="Notes">control air driers c/o no leaks observed. all
satisfactory. no 1 is now running.</column>
<column name="MaintLogID1">BRMR35020212</column>
</row>
<row>
<column name="Notes">2 bags of bio augmentation dosed to
STP</column>
<column name="MaintLogID1">BRMR35020213</column>
</row>
<row>
<column name="Notes">compressors c/o no.3 is now running, no.2 is
stand by no1 is priority no.3, all solenoid valves cleaned and all wayer
filters
cleaned. </column>
<column name="MaintLogID1">BRMR35020214</column>
</row>
<row>
<column name="Notes">combustion air inlets are clean and free,
photo resistor on the burner cleaned. </column>
<column name="MaintLogID1">BRMR35020215</column>
</row>
<row>
<column name="Notes">engine oil level checked, satisfactory, fuel
level satisfactory, engine run on test for approx 5 minuets all
satisfactory </column>
<column name="MaintLogID1">BRMR35020216</column>
</row>
<row>
<column name="Notes">work completed as per pm. the backflush outlet
v/v on no.2 cooler is closed tight.</column>
<column name="MaintLogID1">BRMR35020217</column>
</row>
<row>
<column name="Notes">work completed as per pm, the backflush outlet
v/v on no.2 cooler is closed tight.</column>
<column name="MaintLogID1">BRMR35020218</column>
</row>
<row>
<column name="Notes">burner removed, burner was steamed through for
approx 20 mins, tip was removed and allowed to soak in carbon remover.
tip was cleaned and polished with brasso, the condition of the faces was
good.
Corrosion was observed around the fuel oil holes. burner was cleaned up
and reassembled </column>
<column name="MaintLogID1">BRMR35020219</column>
</row>
<row>
<column name="Notes">all burners changed, units removed were
cleaned and are now ready for use, while cleaning the atomiser slight
corrsion was
observed around the fuel oil holes. </column>
<column name="MaintLogID1">BRMR35020220</column>
</row>
<row>
<column name="Notes">all burners were changed, the burners that
were removed were cleaned and are now ready for use. while cleaning the
atomiser tip slight corrosion was observed around the fuel oil
holes.</column>
<column name="MaintLogID1">BRMR35020221</column>
</row>
<row>
<column name="Notes">all burners were changed out, the burners
that were removed were o/h and cleaned and are now ready for use. while
cleaning the
atomiser corrosion was observed around the fuel oil holes.</column>
<column name="MaintLogID1">BRMR35020222</column>
</row>
<row>
<column name="Notes">all burners were changed, the burners that
were removed were o/h and cleaned and are now ready for use, while cleaning
the
atomiser slight corrosion was observed around the fuel oil holes.
</column>
<column name="MaintLogID1">BRMR35020223</column>
</row>
<row>
<column name="Notes">all burners were changed the burners that were
removed were cleaned and are now ready for use. while cleaning the atomiser
corrosion was observed around the fuel oil holes.</column>
<column name="MaintLogID1">BRMR35020224</column>
</row>
<row>
<column name="Notes">All operated satisfactory</column>
<column name="MaintLogID1">BRMR35020225</column>
</row>
<row>
<column name="Notes">All operated satisfactory</column>
<column name="MaintLogID1">BRMR35020226</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020227</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020228</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020229</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020230</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020231</column>
</row>
<row>
<column name="Notes">As per weekly routined</column>
<column name="MaintLogID1">BRMR35020232</column>
</row>
<row>
<column name="Notes">New electronic QA installed in location:
</column>
<column name="MaintLogID1">BRMR35020296</column>
</row>
<row>
<column name="Notes">Inspection completed, IMO SAFETY STICKERS
replaced (except for stbd accommodation
ladder lifebuoy - old one left in place), all satisfactory and ready for
immediate use.</column>
<column name="MaintLogID1">BRMR35020297</column>
</row>
<row>
<column name="Notes">Plant cleaned out inspected and
sprayed</column>
<column name="MaintLogID1">BRMR35020298</column>
</row>
<row>
<column name="Notes">Carried out as per work order for this type of
motor</column>
<column name="MaintLogID1">BRMR35020299</column>
</row>
<row>
<column name="Notes">Fan cleaned and inspected no defects
observed</column>
<column name="MaintLogID1">BRMR35020300</column>
</row>
<row>
<column name="Notes">Hydralic oil and chain case oil levels checked
no water present.
Drain plugs are showing signs of excess use so will need to be replaced
next oil change.</column>
<column name="MaintLogID1">BRMR35020301</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020302</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020303</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020304</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020305</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020306</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020307</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020308</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020309</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020310</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020311</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020312</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020313</column>
</row>
<row>
<column name="Notes">As per PM, All hydraulic valves lubricated
with MP-MG2, All manual valves lubricated with molycote spray.</column>
<column name="MaintLogID1">BRMR35020314</column>
</row>
<row>
<column name="Notes">Hospital Resuscitator Details
---------------------------------------------
Regulator RT03036079
Unit holds pressure with no apparent leaks on lines and regulator. Patient
alarm works ok.
Unit works satisfactory.
Regulator RT03036075
PLJ
</column>
<column name="MaintLogID1">BRMR35020315</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
Safety posters placed on the bulkhead: "launching procedure" and
"vital action after launching".
IMO Sign (sticker) "liferaft" replaced.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020316</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020317</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020318</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020319</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020320</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020321</column>
</row>
<row>
<column name="Notes">All the valves as indicated on the pm were
operated all vales are free to move.</column>
<column name="MaintLogID1">BRMR35020322</column>
</row>
<row>
<column name="Notes">work was completed as per pm, the LEDs of the
probes reacted satifactory to the conditions, lit in oil/air and unlit in
water,
all solenoid valves operated satifactory according to the pm. </column>
<column name="MaintLogID1">BRMR35020323</column>
</row>
<row>
<column name="Notes">work was completed as per pm, the tension of
the belt was satisfactory, the sprinkler pump was inspected visually all ok
and the
valve was checked and found free to operate.</column>
<column name="MaintLogID1">BRMR35020324</column>
</row>
<row>
<column name="Notes">work was completed as per pm, the tension of
the dynamo belt was found satisfactory, the sprinkler pump was visually
inspected all ok, the valve was checked and found free to operate.</column>
<column name="MaintLogID1">BRMR35020325</column>
</row>
<row>
<column name="Notes">oil, water, and fuel levels ok, engine run on
test all satisfactory, shaft turned both ahead and astern. battery returned
to normal</column>
<column name="MaintLogID1">BRMR35020326</column>
</row>
<row>
<column name="Notes">oil, water, fuel levels checked and found ok,
engine run on test all satisfactory, shaft tested ahead and astern, battery
returned
to normal. </column>
<column name="MaintLogID1">BRMR35020327</column>
</row>
<row>
<column name="Notes">work completed as per pm, batteries charging,
all hatches ok all equiptment in order, air cylinders pressure satisfactoy
190 bar,
sprinkler system ok valve free and belts ok. </column>
<column name="MaintLogID1">BRMR35020328</column>
</row>
<row>
<column name="Notes">work completed as per pm,batteries charging,
all hatches ok, all equiptment in order prop gasket ok, pressure of air
cylinders
satisfactory, 190 bar. sprinkler system ok vavle free and belts
ok.</column>
<column name="MaintLogID1">BRMR35020329</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020330</column>
</row>
<row>
<column name="Notes">work compled as per pm, no.2 is now in lead,
operation satisfactory,</column>
<column name="MaintLogID1">BRMR35020331</column>
</row>
<row>
<column name="Notes">work completed as per pm, cell was cleaned
with fresh water ppm reading is zero, no calibration necessary</column>
<column name="MaintLogID1">BRMR35020332</column>
</row>
<row>
<column name="Notes">work completed as per pm ,no 2 compressor is
now in lead operation satifactory </column>
<column name="MaintLogID1">BRMR35020333</column>
</row>
<row>
<column name="Notes">all flap included in the pm were operated,
operation of all dampers was found satisfactory</column>
<column name="MaintLogID1">BRMR35020334</column>
</row>
<row>
<column name="Notes">work was completed as per pm, the valve
operated when on sensing air and alarm was activated, system was returned
to
normal on completion.</column>
<column name="MaintLogID1">BRMR35020335</column>
</row>
<row>
<column name="Notes">work was completed as per pm.</column>
<column name="MaintLogID1">BRMR35020336</column>
</row>
<row>
<column name="Notes">work completed as per pm the units were
changed over and no.2 unit is now in use operation is satifactory</column>
<column name="MaintLogID1">BRMR35020337</column>
</row>
<row>
<column name="Notes">work completed as per pm units were changed
over and no.2 unit is now in use operation is satisfactory </column>
<column name="MaintLogID1">BRMR35020338</column>
</row>
<row>
<column name="Notes">work completed as per pm, units changed over
no.2 unit is now in use, operation satisfactory</column>
<column name="MaintLogID1">BRMR35020339</column>
</row>
<row>
<column name="Notes">work completed as per pmstp dosed as per
pm</column>
<column name="MaintLogID1">BRMR35020340</column>
</row>
<row>
<column name="Notes">work completed as per pm, all air inlets free,
photo resistor ic clean</column>
<column name="MaintLogID1">BRMR35020341</column>
</row>
<row>
<column name="Notes">All detector heads tested using 50% LEL gas.
Al heads alarmed at 30% and reached 45%- 55%, within the 10% tolerance of
the meter.</column>
<column name="MaintLogID1">BRMR35020342</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All satisfactory, also pump checked with Entek.
Run.Hours:21.7</column>
<column name="MaintLogID1">BRMR35020343</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020344</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020345</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020346</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020347</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020348</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020349</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020350</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020351</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020352</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020353</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020354</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020355</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020356</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020357</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020358</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020359</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020360</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020361</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020362</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
</column>
<column name="MaintLogID1">BRMR35020363</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
Software upgrade required, being arranged.
</column>
<column name="MaintLogID1">BRMR35020364</column>
</row>
<row>
<column name="Notes">Equipment functioning correctly.
Software upgrade required, being arranged.
</column>
<column name="MaintLogID1">BRMR35020365</column>
</row>
<row>
<column name="Notes">Equipment functioning correctlyon Bottom
Track.
Error reading on Water Track.
Transducer heads to be cleaned.
</column>
<column name="MaintLogID1">BRMR35020366</column>
</row>
<row>
<column name="Notes">Inspection completed, new seal made and
shifter fixed for ISC placed in the F.C.C.,
all bolts and nuts greased, equipment in good condition, ready for
immediate use.</column>
<column name="MaintLogID1">BRMR35020367</column>
</row>
<row>
<column name="Notes">Thruster swung 8 deg each was pressure reading
1 mpa. all fittings found to be secure
coupling and motir greased</column>
<column name="MaintLogID1">BRMR35020368</column>
</row>
<row>
<column name="Notes">Thruster ran on test when swung each way 8 deg
readings checked with bridge no deviation observed. Headed tank level alarm
tested
All pressures and temperaturea compare with previous history</column>
<column name="MaintLogID1">BRMR35020369</column>
</row>
<row>
<column name="Notes">All valves inspected and operated through full
range.
all valves either triped and reset by air or wire accordingly.</column>
<column name="MaintLogID1">BRMR35020370</column>
</row>
<row>
<column name="Notes">Filter shows clear when running oil sample
looks clear good level in tank</column>
<column name="MaintLogID1">BRMR35020371</column>
</row>
<row>
<column name="Notes">Fan inspected in place
impeller found to be in good condition
motor cleaned
all fittings appear tight
Hours17825</column>
<column name="MaintLogID1">BRMR35020372</column>
</row>
<row>
<column name="Notes">Fan inspected in place
impeller found to be in good condition
motor cleaned
all fittings appear tight
hours 17059
amps 35</column>
<column name="MaintLogID1">BRMR35020373</column>
</row>
<row>
<column name="Notes">Oil, HP alarms tested Lp cut out observed
operation of unloader checked.</column>
<column name="MaintLogID1">BRMR35020374</column>
</row>
<row>
<column name="Notes">Oil, HP alarms tested Lp cut out observed
operation of unloader checked.</column>
<column name="MaintLogID1">BRMR35020375</column>
</row>
<row>
<column name="Notes">Temperatures checked condenser drained and
inspected via anode covers</column>
<column name="MaintLogID1">BRMR35020376</column>
</row>
<row>
<column name="Notes">Inspection carried out as 1-7 on workorder
In addition oil wes observed comimg out from under fan cover on inspection
o ring 63 in the mechanical seal
was found to be britle and cracked replaced from spare</column>
<column name="MaintLogID1">BRMR35020377</column>
</row>
<row>
<column name="Notes">Inspection completed, 2 stretchers located in
ship's hospital found in good condition
and ready for immediate use. Robinson (standard) stretcher a bit worn (used
for drills),
order for a new PARAGUARD stretcher placed by C/O.
X3/O G.B.</column>
<column name="MaintLogID1">BRMR35020378</column>
</row>
<row>
<column name="Notes">work completed as per pm, all filters and lens
cleaned, sealing air ok.</column>
<column name="MaintLogID1">BRMR35020379</column>
</row>
<row>
<column name="Notes">work completed as per pm, all filters and
lenses cleaned sealing air is ok.</column>
<column name="MaintLogID1">BRMR35020380</column>
</row>
<row>
<column name="Notes">The forward whistle was operated, operation
was found to be satisfactory. The inspection door was opened, nothing
unusual
was observed, all parts looked to be in good order, no erosion or corrosion
was observed. whistle was observed to be secure. </column>
<column name="MaintLogID1">BRMR35020381</column>
</row>
<row>
<column name="Notes">The aft whistle was operated both manually and
from the panel, operation was found satisfactory. manual operating
mechanisms
in good order, no corrosion or erosion was observed, no leaks observed, all
secure.</column>
<column name="MaintLogID1">BRMR35020382</column>
</row>
<row>
<column name="Notes">Work was completed as per pm, all dry powder
extinguishers were agitated. All extinguishers were inspected, all seals
were
found satisfactory, condtion of hoses ok all extinguishers secure.
</column>
<column name="MaintLogID1">BRMR35020383</column>
</row>
<row>
<column name="Notes">All co2 extinguishers were weighed all weithts
were found satisfactory, external condition of all extinguishers was good,
condition
of hoses and horns good, all extinguishers were found secure.</column>
<column name="MaintLogID1">BRMR35020384</column>
</row>
<row>
<column name="Notes">Fan inspected in place
impeller found to be in good condition
motor cleaned
all fittings appear tight
hours 17059
amps 35</column>
<column name="MaintLogID1">BRMR35020385</column>
</row>
<row>
<column name="Notes">Inspection completed, all equipment
satisfactory and ready for immediate use.
Painter shackle found rusted - to be chipped and greased. C/O advised.
G.B.</column>
<column name="MaintLogID1">BRMR35020386</column>
</row>
<row>
<column name="Notes">the cocks were operated, all found
satisfactory.</column>
<column name="MaintLogID1">BRMR35020387</column>
</row>
<row>
<column name="Notes">cocks were operated all found
satisfactory.</column>
<column name="MaintLogID1">BRMR35020388</column>
</row>
<row>
<column name="Notes">all fire dampers as per pm were operated,
operation of no3 supply fan found to be a little stiff the damper was
greased and is
ok now, the operation of all other dampers found satisfactory. all supply
fan ans exhaust fan dampers were greased.</column>
<column name="MaintLogID1">BRMR35020389</column>
</row>
<row>
<column name="Notes">work completed as per pm, all strums found to
be clean. condition of all seals satisfactory, </column>
<column name="MaintLogID1">BRMR35020390</column>
</row>
<row>
<column name="Notes">work completed as per pm. </column>
<column name="MaintLogID1">BRMR35020391</column>
</row>
<row>
<column name="Notes">All sample points tested and alarm proved
operational. Cargo machinery room trips tested and proved operational.
Detectors calibrated, All internal pipework and pump diaphragms inspected
and found to be in good condition.
No defects found.</column>
<column name="MaintLogID1">BRMR35020392</column>
</row>
<row>
<column name="Notes">Anchor lashing chains chipped and
painted.</column>
<column name="MaintLogID1">BRMR35020393</column>
</row>
<row>
<column name="Notes">Anchor lashing chains chipped and
painted</column>
<column name="MaintLogID1">BRMR35020394</column>
</row>
<row>
<column name="Notes">Air starter tested - all satisfactory.
No air leaks and no grease leaks found.
TDI grease on order.
D/G running hours:106.5</column>
<column name="MaintLogID1">BRMR35020396</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
No.1 bus tie closed this month.
D/G run. hours:106.5</column>
<column name="MaintLogID1">BRMR35020397</column>
</row>
<row>
<column name="Notes">Work order carried out.
Valve replaced with spare one, all gaskets renewed.
Also all bolts were changed.
All tested no leaks found.
Second spare valve (for no.2 evap.) is kept in store.
No.1 evap. run hours: 20396.8</column>
<column name="MaintLogID1">BRMR35020398</column>
</row>
<row>
<column name="Notes">Fan opened and inspected no defects
abserved</column>
<column name="MaintLogID1">BRMR35020399</column>
</row>
<row>
<column name="Notes">Pump and motor inspected externally, coupling
checked, oil renewed amps and throughput are all satisfactory</column>
<column name="MaintLogID1">BRMR35020400</column>
</row>
<row>
<column name="Notes">Greased as per pm, air breather clear</column>
<column name="MaintLogID1">BRMR35020401</column>
</row>
<row>
<column name="Notes">Greased as per pm, air breather clear</column>
<column name="MaintLogID1">BRMR35020402</column>
</row>
<row>
<column name="Notes">Greased as per pm, air breather clear</column>
<column name="MaintLogID1">BRMR35020403</column>
</row>
<row>
<column name="Notes">20/08/06 Boat lowered to water, engine and
spray tested satisfactory.
21/08/06 Boat hung off in davits, release gear tested, lubricated and all
ok.</column>
<column name="MaintLogID1">BRMR35020404</column>
</row>
<row>
<column name="Notes">20/08/06 Boat lowered to water, engine and
spray tested satisfactory.
21/08/06 boat hung off in davits. Release gear tested and lubricated all
ok.</column>
<column name="MaintLogID1">BRMR35020405</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020408</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020409</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020410</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020411</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020412</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020413</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020414</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020415</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020416</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020417</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020418</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020419</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020420</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020421</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020422</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020423</column>
</row>
<row>
<column name="Notes">Completed, No defects found</column>
<column name="MaintLogID1">BRMR35020424</column>
</row>
<row>
<column name="Notes">Condenser isolated and drained, Inspection
ports opened up and tubes found to be clean and free from any fouling.
No anodes fitted as condenser is fresh water cooled.</column>
<column name="MaintLogID1">BRMR35020425</column>
</row>
<row>
<column name="Notes">Inspection completed.
Gears in very good condition with even tooth contact evident.
Oil in good condition.
Run.Hours:17753</column>
<column name="MaintLogID1">BRMR35020426</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020427</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020428</column>
</row>
<row>
<column name="Notes">Cooler isolated and water drained.
All inspection covers removed and cooler checked.
No damage or wear was found.
Cooler de-isolated and checked for leaks - all ok.</column>
<column name="MaintLogID1">BRMR35020429</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020430</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020431</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020432</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020433</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020434</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020435</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020436</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020437</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020438</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020439</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020440</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020441</column>
</row>
<row>
<column name="Notes">Tested successfully as per PM routine. All
alarm points sounded.</column>
<column name="MaintLogID1">BRMR35020442</column>
</row>
<row>
<column name="Notes">Alarm function operational.
</column>
<column name="MaintLogID1">BRMR35020443</column>
</row>
<row>
<column name="Notes">Alarm function operational.
</column>
<column name="MaintLogID1">BRMR35020444</column>
</row>
<row>
<column name="Notes">Alarm function operational.
</column>
<column name="MaintLogID1">BRMR35020445</column>
</row>
<row>
<column name="Notes">Outside lighting operational with no low
insulation readings.
</column>
<column name="MaintLogID1">BRMR35020446</column>
</row>
<row>
<column name="Notes">Fire heads tested as per routes 15 and 16,
all satisfactory.
</column>
<column name="MaintLogID1">BRMR35020447</column>
</row>
<row>
<column name="Notes">All tests being carried out and entered in the
GMDSS log book.
</column>
<column name="MaintLogID1">BRMR35020448</column>
</row>
<row>
<column name="Notes">Indicators showing correct value, linkages
appear in good condition.
</column>
<column name="MaintLogID1">BRMR35020449</column>
</row>
<row>
<column name="Notes">Lift inspection recorded in QAV20
Minor flattening observed on suspension wires but diameters still
satisfactory.</column>
<column name="MaintLogID1">BRMR35020450</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020451</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020452</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020453</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020454</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020455</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020456</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020457</column>
</row>
<row>
<column name="Notes">As per routine sheet in engine log
book</column>
<column name="MaintLogID1">BRMR35020458</column>
</row>
<row>
<column name="Notes">As per PM, Inspection cover removed and tower
ventilated.
Several spray nozzles found blocked with wood and shells.
A large build up of calcium was found below the burner in the furnace, It
appears to be from the air purge lines at the inspection
ports.
Demister and internals found in good condition.
All debris was removed and tower boxed up.
</column>
<column name="MaintLogID1">BRMR35020459</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
Oil slighty discoloured, but nothing found.
Running hours:5990.7</column>
<column name="MaintLogID1">BRMR35020460</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020461</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020462</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020463</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020464</column>
</row>
<row>
<column name="Notes">All alrms tested ok</column>
<column name="MaintLogID1">BRMR35020465</column>
</row>
<row>
<column name="Notes">Alarms tested and ok.
Steam leak on line to gas house, joint replaced. Aft bilge well educted
dry.</column>
<column name="MaintLogID1">BRMR35020466</column>
</row>
<row>
<column name="Notes">tested as per rota</column>
<column name="MaintLogID1">BRMR35020467</column>
</row>
<row>
<column name="Notes">tested as per rota</column>
<column name="MaintLogID1">BRMR35020468</column>
</row>
<row>
<column name="Notes">all valves operated and greased as
req'd</column>
<column name="MaintLogID1">BRMR35020469</column>
</row>
<row>
<column name="Notes">All points breased as per pm.
Note: unable to inspect wire termination at jib end due to poor access.
No damage sighted.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020513</column>
</row>
<row>
<column name="Notes">Cleaned and inspected</column>
<column name="MaintLogID1">BRMR35020514</column>
</row>
<row>
<column name="Notes">Cleaned and inspected</column>
<column name="MaintLogID1">BRMR35020515</column>
</row>
<row>
<column name="Notes">All items as per list.
4Z9100705ES
590080371ES
590080373ES</column>
<column name="MaintLogID1">BRMR35020607</column>
</row>
<row>
<column name="Notes">Calibrated as per manufacturers instructions.
Reading not correct, ongoing investigation, Possibly new probe
required.</column>
<column name="MaintLogID1">BRMR35020608</column>
</row>
<row>
<column name="Notes">work complted as per pm, batteries charging,
equiptment in order, air cylinder pressure checked, all satisfactory,
sprinkler
pump valve operated the pump was tested in the water last month, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35020609</column>
</row>
<row>
<column name="Notes">Calibrated as per manufacturers
instructions.</column>
<column name="MaintLogID1">BRMR35020610</column>
</row>
<row>
<column name="Notes">Calibrated as per manufacturers
instructions.</column>
<column name="MaintLogID1">BRMR35020611</column>
</row>
<row>
<column name="Notes">Top heater only in service 2 month so PM not
done.
Visuali inspetion carried out</column>
<column name="MaintLogID1">BRMR35020612</column>
</row>
<row>
<column name="Notes">Running hours 12336
3.4 amps
No defects observed</column>
<column name="MaintLogID1">BRMR35020613</column>
</row>
<row>
<column name="Notes">Running hours 12336
amps 3.4
no defects observed</column>
<column name="MaintLogID1">BRMR35020614</column>
</row>
<row>
<column name="Notes">running hours 14917
amps 3.4
no defects observed</column>
<column name="MaintLogID1">BRMR35020615</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020616</column>
</row>
<row>
<column name="Notes">Both port and Stb'd liquid and vapour
manifold pressure gauges checked & calibrated.</column>
<column name="MaintLogID1">BRMR35020617</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020618</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020619</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020620</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020621</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020622</column>
</row>
<row>
<column name="Notes">Condenser found to be clean</column>
<column name="MaintLogID1">BRMR35020623</column>
</row>
<row>
<column name="Notes">no defect</column>
<column name="MaintLogID1">BRMR35020624</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020625</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020626</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020627</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020628</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020629</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020630</column>
</row>
<row>
<column name="Notes">All alarms and trips tested no defects
observed</column>
<column name="MaintLogID1">BRMR35020631</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020632</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020633</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020634</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020635</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020636</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35020637</column>
</row>
<row>
<column name="Notes">No defects observed 3.5 amps
hours 7935.8</column>
<column name="MaintLogID1">BRMR35020638</column>
</row>
<row>
<column name="Notes">No defects observed noise and housing
satisfactory</column>
<column name="MaintLogID1">BRMR35020639</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020640</column>
</row>
<row>
<column name="Notes">work completed as per pm, compressors c/o all
satisfactory.</column>
<column name="MaintLogID1">BRMR35020641</column>
</row>
<row>
<column name="Notes">work completed as per pm, compressors c/o all
satisfactory.</column>
<column name="MaintLogID1">BRMR35020642</column>
</row>
<row>
<column name="Notes">work completed as per pm, no calibration
necessary.</column>
<column name="MaintLogID1">BRMR35020643</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation of all all
dampers as per pm satisfactory.</column>
<column name="MaintLogID1">BRMR35020644</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020645</column>
</row>
<row>
<column name="Notes">work completed as per pm,</column>
<column name="MaintLogID1">BRMR35020646</column>
</row>
<row>
<column name="Notes">work completed as per pm no 1 unit now in use
all satisfactory.</column>
<column name="MaintLogID1">BRMR35020647</column>
</row>
<row>
<column name="Notes">work completed as per pm, no 1 unit now in use
all satisfactory</column>
<column name="MaintLogID1">BRMR35020648</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020649</column>
</row>
<row>
<column name="Notes">work completed as per pm air inlets all free
from obstruction.</column>
<column name="MaintLogID1">BRMR35020650</column>
</row>
<row>
<column name="Notes">work completed as per pm, no leaks observed.
the calorifier is now permantly running on the electric heating elements.
all satisfactory.</column>
<column name="MaintLogID1">BRMR35020651</column>
</row>
<row>
<column name="Notes">work completed as per pm, all valves as per pm
operated. </column>
<column name="MaintLogID1">BRMR35020652</column>
</row>
<row>
<column name="Notes">work completed as per pm, all grease points
greased with high temperature grease.</column>
<column name="MaintLogID1">BRMR35020653</column>
</row>
<row>
<column name="Notes">fan grease and inspected</column>
<column name="MaintLogID1">BRMR35020654</column>
</row>
<row>
<column name="Notes">fan grease and inspected</column>
<column name="MaintLogID1">BRMR35020655</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation tested,
inspection door opened, no signs of erosion or corrosion. all found to be
secure. </column>
<column name="MaintLogID1">BRMR35020656</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation of whistle
tested. manual opetating mechanisms are free, no erosion or corrosion
observed, no leaks observed all secure.</column>
<column name="MaintLogID1">BRMR35020657</column>
</row>
<row>
<column name="Notes">Inspection completed, all lifebuoys in good
condition and ready for immediate use. All grablines
replaced, life buoy attachment lines on MOB life buoys (bridge wings)
replaced.
06/09/06 G.Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35020658</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020659</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020660</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020661</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020662</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020663</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020664</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020665</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020666</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020667</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020668</column>
</row>
<row>
<column name="Notes">No defects or abnormal noise or
vibration.</column>
<column name="MaintLogID1">BRMR35020669</column>
</row>
<row>
<column name="Notes">New probe calibrated and fitted, System
running.</column>
<column name="MaintLogID1">BRMR35020670</column>
</row>
<row>
<column name="Notes">As per PM, all pressure transmitters
calibrated/ Checked using druck. All satisfactory.</column>
<column name="MaintLogID1">BRMR35020671</column>
</row>
<row>
<column name="Notes">All ESD & tank protection trips tested and
found to be operational at correct setpoint.</column>
<column name="MaintLogID1">BRMR35020672</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020678</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020679</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020680</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020681</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020682</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020683</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020684</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020685</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020686</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020687</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020688</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020689</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020690</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020691</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020692</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020693</column>
</row>
<row>
<column name="Notes">Completed, No defects found.</column>
<column name="MaintLogID1">BRMR35020694</column>
</row>
<row>
<column name="Notes">Proximity switch changed with spare,
ROB: 2</column>
<column name="MaintLogID1">BRMR35020695</column>
</row>
<row>
<column name="Notes">One man bridge alarm tested as per pm routine.
Watch call tested.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35020696</column>
</row>
<row>
<column name="Notes">All alrms tested ok</column>
<column name="MaintLogID1">BRMR35020698</column>
</row>
<row>
<column name="Notes">all alarms tested ok</column>
<column name="MaintLogID1">BRMR35020699</column>
</row>
<row>
<column name="Notes">tested as per rota</column>
<column name="MaintLogID1">BRMR35020700</column>
</row>
<row>
<column name="Notes">tested as per rota</column>
<column name="MaintLogID1">BRMR35020701</column>
</row>
<row>
<column name="Notes">v/vs worked and greased</column>
<column name="MaintLogID1">BRMR35020702</column>
</row>
<row>
<column name="Notes">Wire run off, cleaned and inspected along
entire length.
Wire greased and eye end wrapped in denso for additional protection.
Noted one guide roller flattened, new roller on order since June
2006.</column>
<column name="MaintLogID1">BRMR35020704</column>
</row>
<row>
<column name="Notes">
stowed in trunk deck store, all ok.</column>
<column name="MaintLogID1">BRMR35020705</column>
</row>
<row>
<column name="Notes">Wire run off for 3M inspection.
Guide rollers reomved, cleaned and greased, minor wear otherwise all
satisfactory.
Item
Alarm Trip Results
Electrical, Mechanical Overspeed
19802000 19051910
Low L.O Pressure
0.06mpa 0.05mpa Operational
D/G Auto Start.
Ok Operational
Low Vacuum Pressure.
-0.05mpa -0.013mpa Operational
Excess Vibration
80um 140um Operational
Rotor Axial Movement.
0.5mm 0.7mm Operational
Hand Trip
Ok Operational
Remote Stop
Ok Operational
Gland Steam Low Pressure
-13.3 Operational
Low L.O sump level.
Ok Operational
Turning gear interlock.
Ok Operational
Priming Pump Auto Start/Stop Cut in 40
Cut Out 100 Kpa 40/100
Air cooler water leakage.
Ok Operational
IAS (R,S,T) Winding Temp
165 c 170 c Operational
IAS D.E Bearing Oil Temp
90c 95c Operational
IAS N.D.E Bearing Oil Temp
90 c 95 c Operational
IAS DE Bearing TempIAS N.D.E Bearing Temp 90 c
95 c Operational
IAS Turbine Thrust Bearing High
75 c Operational
Running hours:20713</column>
<column name="MaintLogID1">BRMR35020771</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
Item
Alarm Trip Results
Electrical, Mechanical Overspeed
19802000 19051910
Low L.O Pressure
0.06mpa 0.05mpa Operational
D/G Auto Start.
Ok Operational
Low Vacuum Pressure.
-0.05mpa -0.013mpa Operational
Excess Vibration
80um 140um Operational
Rotor Axial Movement.
0.5mm 0.7mm Operational
Hand Trip
Ok Operational
Remote Stop
Ok Operational
Gland Steam Low Pressure
-13.3 Operational
Low L.O sump level.
Ok Operational
Turning gear interlock.
Ok Operational
Priming Pump Auto Start/Stop Cut in 40
Cut Out 100 Kpa 40/100
Air cooler water leakage.
Ok Operational
IAS (R,S,T) Winding Temp
165 c 170 c Operational
IAS D.E Bearing Oil Temp
90c 95c Operational
IAS N.D.E Bearing Oil Temp
90 c 95 c Operational
IAS DE Bearing TempIAS N.D.E Bearing Temp 90 c
95 c Operational
IAS Turbine Thrust Bearing High
75 c Operational
Running hours:18089</column>
<column name="MaintLogID1">BRMR35020772</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020773</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020774</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020775</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020776</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020777</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020778</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020779</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020780</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020781</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020782</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020783</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020784</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020785</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020786</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020787</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35020788</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020789</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020790</column>
</row>
<row>
<column name="Notes">Ran for main condenser shutdown</column>
<column name="MaintLogID1">BRMR35020791</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020792</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020793</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020794</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020795</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020796</column>
</row>
<row>
<column name="Notes">no defects observed unit fully sprayed as per
the PM</column>
<column name="MaintLogID1">BRMR35020797</column>
</row>
<row>
<column name="Notes">No defects observed, all alarms operated ,
piolt bottle weight checked all acceptable</column>
<column name="MaintLogID1">BRMR35020798</column>
</row>
<row>
<column name="Notes">Carried out on all 3 motors all of ships
compliment instructed in use</column>
<column name="MaintLogID1">BRMR35020799</column>
</row>
<row>
<column name="Notes">Fan internally inspected last month no defects
observed</column>
<column name="MaintLogID1">BRMR35020800</column>
</row>
<row>
<column name="Notes">Fan internally inspected last month no defects
observed</column>
<column name="MaintLogID1">BRMR35020801</column>
</row>
<row>
<column name="Notes">Oil not changed on this occasion,
operation of plant observed no defects to note</column>
<column name="MaintLogID1">BRMR35020802</column>
</row>
<row>
<column name="Notes">condensers inspected during plant changover no
defects to note both found to be clean</column>
<column name="MaintLogID1">BRMR35020803</column>
</row>
<row>
<column name="Notes">Condenser tubes found to be blocked with sea
life for the first few inches, rodded through and pressure washed.
Heat shrink sleves fitted to MGPS anodes (see pictures in T drive), these
found to be very wasted. approx 40 - 50 mm
at the narrowest point.
Large amounts of marine life found in the main circ inlet line on the
outside of the 90 deg elbow.
Sawdust injection found to be blocked with marine growth so cleared.
Damage to coating in the scoop cleaned and coated (see pictures on T drive)
Outlet side a layer of slime removed.</column>
<column name="MaintLogID1">BRMR35020804</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020805</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020806</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020807</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020808</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020809</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020810</column>
</row>
<row>
<column name="Notes">Compleated as per routines sheet no defects
observed.</column>
<column name="MaintLogID1">BRMR35020811</column>
</row>
<row>
<column name="Notes">work completed as per pm, gear box level
satisfactory, batteries charging, inspection of batteries done nothing
unusual found</column>
<column name="MaintLogID1">BRMR35020812</column>
</row>
<row>
<column name="Notes">work completed as per pm,level of gearbox
satisfactory. batteries charging, batteries checked nothing unusual
found.</column>
<column name="MaintLogID1">BRMR35020813</column>
</row>
<row>
<column name="Notes">work completed as per, tension of v belt
satisfactory, sprinkler pump valve operated.</column>
<column name="MaintLogID1">BRMR35020814</column>
</row>
<row>
<column name="Notes">work completed as per pm, tension of dynamo v
belt ok, sprinkler pump checked when engine was running, no abnormalities
found sprinler pump valve operated and found free.</column>
<column name="MaintLogID1">BRMR35020815</column>
</row>
<row>
<column name="Notes">this machine is currently out of service and
waiting for spares, the safety valve was tested but the rest of the alarms
and trips
were not tested due to the machine being out of service.</column>
<column name="MaintLogID1">BRMR35020816</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.2 is now the
running machine, no.3 in standby and no1 is currently out of
service.</column>
<column name="MaintLogID1">BRMR35020817</column>
</row>
<row>
<column name="Notes">work completed as per pm no.2 is now the
running machine, no.3 is the standby machine, no.1 compressor is currently
out
of service.</column>
<column name="MaintLogID1">BRMR35020818</column>
</row>
<row>
<column name="Notes">work completed as per pm sump level ok, fuel
level ok engine tested for 5 mins all ok</column>
<column name="MaintLogID1">BRMR35020819</column>
</row>
<row>
<column name="Notes">work completed as per pm, hoses tested as per
rota. all ok </column>
<column name="MaintLogID1">BRMR35020820</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.2 compressor is
now the running machine, no3 is standby and no.1 is currently out of
service</column>
<column name="MaintLogID1">BRMR35020821</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.2 compressor oi
now the running compressor. no.3 compressor is the standby compressor,
no.1 compresor is currently out of service.</column>
<column name="MaintLogID1">BRMR35020822</column>
</row>
<row>
<column name="Notes">work completed as per pm, engine tested all
satisfactory, all oil levels ok.</column>
<column name="MaintLogID1">BRMR35020823</column>
</row>
<row>
<column name="Notes">work completed as per pm, engine tested all
satisfactory, all oil levels ok,</column>
<column name="MaintLogID1">BRMR35020824</column>
</row>
<row>
<column name="Notes">work completed as per pm, batteries charging
all equiptment in order air bottles pressures satisfactory.</column>
<column name="MaintLogID1">BRMR35020825</column>
</row>
<row>
<column name="Notes">work completed as per pm, batteries charging
equiptent in order air cylinder pressures satisfactory.</column>
<column name="MaintLogID1">BRMR35020826</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020827</column>
</row>
<row>
<column name="Notes">work completed as per pm, compressors c/o all
satifactory</column>
<column name="MaintLogID1">BRMR35020828</column>
</row>
<row>
<column name="Notes">work completed as per pm, compressor c/o all
satisfactory.</column>
<column name="MaintLogID1">BRMR35020829</column>
</row>
<row>
<column name="Notes">work completed as per, no calibration
necessary</column>
<column name="MaintLogID1">BRMR35020830</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation of all
dampers as per pm satisfactory.</column>
<column name="MaintLogID1">BRMR35020831</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation of alarm
and valve satisfactory</column>
<column name="MaintLogID1">BRMR35020832</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35020833</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.2 unit is now in
use. all satisfactory.</column>
<column name="MaintLogID1">BRMR35020834</column>
</row>
<row>
<column name="Notes">Motor insulation readings 200+Megohms to
earth.
No signs of burning, all contacts in good condition, terminals secure.
</column>
<column name="MaintLogID1">BRMR35020835</column>
</row>
<row>
<column name="Notes">Batteries put on load for 2 hours.
Voltage at end of test 24.83 Volts, discharge current 3.0 Amps.
Details recorded in GMDSS Log Book.
</column>
<column name="MaintLogID1">BRMR35020836</column>
</row>
<row>
<column name="Notes">Battery voltages showing,
12.63V, 12.63V, 12.62V, 12.60V.
</column>
<column name="MaintLogID1">BRMR35020837</column>
</row>
<row>
<column name="Notes">Battery voltages as below,
Fwd 13.09V on load 11.71V
Aft 13.17V on load 11.83V
</column>
<column name="MaintLogID1">BRMR35020838</column>
</row>
<row>
<column name="Notes">Battery readings,
fwd 13.02V on load 12.13V
aft 13.10V on load 12.21V
</column>
<column name="MaintLogID1">BRMR35020839</column>
</row>
<row>
<column name="Notes">Battery voltages as below,
fwd 13.37V on load 11.96V
aft 13.31V on load 11.93V
</column>
<column name="MaintLogID1">BRMR35020840</column>
</row>
<row>
<column name="Notes">zero calibration done,
all conections and fittings checked tight all apears in working
order.</column>
<column name="MaintLogID1">BRMR35020841</column>
</row>
<row>
<column name="Notes">Zero calibration done
all fixtores and connections checked,
all working satisfactory</column>
<column name="MaintLogID1">BRMR35020842</column>
</row>
<row>
<column name="Notes">Operation of valves all satisfactory
all switches checked
all solonoids ok</column>
<column name="MaintLogID1">BRMR35020843</column>
</row>
<row>
<column name="Notes">Operation of valves all satisfactory
all switches checked
all solonoids ok</column>
<column name="MaintLogID1">BRMR35020844</column>
</row>
<row>
<column name="Notes">Inspection carried out 03/08/06
MER/G/005
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020862</column>
</row>
<row>
<column name="Notes">Inspection Completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020863</column>
</row>
<row>
<column name="Notes">Inspection Completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020864</column>
</row>
<row>
<column name="Notes">Inspection Completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020865</column>
</row>
<row>
<column name="Notes">Inspection Completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35020866</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020867</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020868</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020869</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020870</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
Transformer mounting brackets in good condition.
</column>
<column name="MaintLogID1">BRMR35020871</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020872</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020873</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020874</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020875</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020876</column>
</row>
<row>
<column name="Notes">Motor windings showing 200+Mohms to earth.
No signs of burning, all connections secure and contacts in good
condition.
</column>
<column name="MaintLogID1">BRMR35020877</column>
</row>
<row>
<column name="Notes">307 307 293 295
315 315 298 298 230 230
230 230 103 99.7 102 99.2 242 242
99 99 All batteries
in good condition.
UPS 6 Battery number 6 subject of GCR.
</column>
<column name="MaintLogID1">BRMR35020878</column>
</row>
<row>
<column name="Notes">Battery voltage after 2 hours on load 24.81V.
</column>
<column name="MaintLogID1">BRMR35020879</column>
</row>
<row>
<column name="Notes">alarms tested ok.
</column>
<column name="MaintLogID1">BRMR35020998</column>
</row>
<row>
<column name="Notes">All indicators correct.
Linkages appear in good condition.
</column>
<column name="MaintLogID1">BRMR35020999</column>
</row>
<row>
<column name="Notes">All tests being carried out and recorded in
the GMDSS log book.
</column>
<column name="MaintLogID1">BRMR35021000</column>
</row>
<row>
<column name="Notes">Fire heads tested satisfactorily, routes 25
and 26.
</column>
<column name="MaintLogID1">BRMR35021001</column>
</row>
<row>
<column name="Notes">Alarm function correct.
</column>
<column name="MaintLogID1">BRMR35021002</column>
</row>
<row>
<column name="Notes">Alarm function correct.
</column>
<column name="MaintLogID1">BRMR35021003</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.3 is now runing
machine no.2 in standby,</column>
<column name="MaintLogID1">BRMR35021004</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021005</column>
</row>
<row>
<column name="Notes">work completed as per pm operation
satisfactory all oil levels ok.</column>
<column name="MaintLogID1">BRMR35021006</column>
</row>
<row>
<column name="Notes">work completed as per pm, hoses tested as per
rota.</column>
<column name="MaintLogID1">BRMR35021007</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.3 is now running
machine and no.2 is in standby.</column>
<column name="MaintLogID1">BRMR35021008</column>
</row>
<row>
<column name="Notes">work completed as per pm, no.3 is running
machine no2 is in standby and no.1 is currently out of service.</column>
<column name="MaintLogID1">BRMR35021009</column>
</row>
<row>
<column name="Notes">work completed as per pm, engine tested all
satisfactory</column>
<column name="MaintLogID1">BRMR35021010</column>
</row>
<row>
<column name="Notes">work completed as per pm, engine tested all
satisfactory</column>
<column name="MaintLogID1">BRMR35021011</column>
</row>
<row>
<column name="Notes">work completed as per pm, all
satisfactory</column>
<column name="MaintLogID1">BRMR35021012</column>
</row>
<row>
<column name="Notes">work completed as per pm, all satisfactory
</column>
<column name="MaintLogID1">BRMR35021013</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35021014</column>
</row>
<row>
<column name="Notes">work completed as per pm all
satisfactory</column>
<column name="MaintLogID1">BRMR35021015</column>
</row>
<row>
<column name="Notes">work completed as per pm all
satisfactory</column>
<column name="MaintLogID1">BRMR35021016</column>
</row>
<row>
<column name="Notes">work completed as per pm operation
satisfactory</column>
<column name="MaintLogID1">BRMR35021017</column>
</row>
<row>
<column name="Notes">operation of all dampers as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35021018</column>
</row>
<row>
<column name="Notes">work completed as per pm operation
satisfactory</column>
<column name="MaintLogID1">BRMR35021019</column>
</row>
<row>
<column name="Notes">work completed as per pm,</column>
<column name="MaintLogID1">BRMR35021020</column>
</row>
<row>
<column name="Notes">work completed as per no.1 unit now in use
operation satisfactory</column>
<column name="MaintLogID1">BRMR35021021</column>
</row>
<row>
<column name="Notes">work completed as per pm no.1 unit now in use
operation satisfactory</column>
<column name="MaintLogID1">BRMR35021022</column>
</row>
<row>
<column name="Notes">STP dosed as per pm</column>
<column name="MaintLogID1">BRMR35021023</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021024</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35021025</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021026</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021027</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021028</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021029</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021030</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021031</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021032</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021033</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021034</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021035</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021036</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021037</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021038</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021039</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021040</column>
</row>
<row>
<column name="Notes">tested as per rota.
Locker catch for D Deck, Stbd, Fwd hose box found broken -
repaired.</column>
<column name="MaintLogID1">BRMR35021043</column>
</row>
<row>
<column name="Notes">valves operated and greased as req'd.
</column>
<column name="MaintLogID1">BRMR35021071</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All operational and satisfactory.
</column>
<column name="MaintLogID1">BRMR35021072</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All operational.</column>
<column name="MaintLogID1">BRMR35021073</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021074</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021075</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021076</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021077</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021078</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021079</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021080</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021081</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021082</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021083</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021084</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021085</column>
</row>
<row>
<column name="Notes">operating satisfactorily.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021142</column>
</row>
<row>
<column name="Notes">Inspection of port lifeboat completed as per
PM.
Air bottle press. 180 bar. 4/E informed.
All found satisfactory, up to date and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021143</column>
</row>
<row>
<column name="Notes">Inspection of stbd lifeboat completed as per
PM.
Air bottle press. 185 bar. 4/E informed.
All found satisfactory, up to date and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021144</column>
</row>
<row>
<column name="Notes">All flaps checked and lubricated as required.
Duct Keel Supply Mushroom Vent spindle found completely dry, hence annoying
squeak.
Spindle greased and all ok. Vent stripped down for chipping and painting as
heavily corroded inside.
</column>
<column name="MaintLogID1">BRMR35021145</column>
</row>
<row>
<column name="Notes">Small gear checked, Lifting Register updated
as req'd.
2 pce triangular bandage and 2 pce No.8 dressing found missing from Galley
Kit. Items
replaced from dispensary stock.</column>
<column name="MaintLogID1">BRMR35021149</column>
</row>
<row>
<column name="Notes">Box clips found broken on Trunk Deck and Deck
Workshop Stations. Boxes replaced.
Eye pads at Trunk Deck Station found wet, pads replaced with dispensary
stock.</column>
<column name="MaintLogID1">BRMR35021150</column>
</row>
<row>
<column name="Notes">work completed as per pm, nothing abnormal
found</column>
<column name="MaintLogID1">BRMR35021151</column>
</row>
<row>
<column name="Notes">work completed as per pm nothing unusual
found</column>
<column name="MaintLogID1">BRMR35021152</column>
</row>
<row>
<column name="Notes">work completed as per nothing unusual
found.</column>
<column name="MaintLogID1">BRMR35021153</column>
</row>
<row>
<column name="Notes">Alarm tested okay.</column>
<column name="MaintLogID1">BRMR35021154</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021155</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021156</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021157</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021158</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021159</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected no defects
observed.</column>
<column name="MaintLogID1">BRMR35021160</column>
</row>
<row>
<column name="Notes">work complete as per pm, valves were found to
be tight strainer was removed and cleaned cooler was backflushed and put
back
on line. </column>
<column name="MaintLogID1">BRMR35021161</column>
</row>
<row>
<column name="Notes">the cooler was taken of line while the
strainer was been cleaned it was back flushed at this time. guages are not
correct </column>
<column name="MaintLogID1">BRMR35021162</column>
</row>
<row>
<column name="Notes">cooler was back flushed at same time cooler
strainer was cleaned this cooler strainer was cleaned, the cooler was
bvackflushed
and put back on line the guages are not correct.</column>
<column name="MaintLogID1">BRMR35021163</column>
</row>
<row>
<column name="Notes">Tested as per PM routine - Alarms functioned
correctly.
Jib head grease pipes removed, grease nipples fitted to jib head grease
point. This will ensure
jib head and sheaves are actually checked and turned whilst
greasing.</column>
<column name="MaintLogID1">BRMR35021172</column>
</row>
<row>
<column name="Notes">Jib head sheaves for inspection.
Sheave bearings removed and cleaned, repacked with fresh grease. Sheaves
now free to turn.
Jib head grease pipes removed and grease nipples fitted to jib head grease
points. This will ensure
jib head checked and sheaves turned whilst greasing in future.</column>
<column name="MaintLogID1">BRMR35021173</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021174</column>
</row>
<row>
<column name="Notes">work completed as per pm, operation of blower
correct, operation of discharge pump correct. operation of discharge pump
for
bilge holding tank correct, high level alarms tested, cut in/cut out
pressure of vacuum pump is now -0.3 to -0.4 operation of low
vacuum alarm tested.</column>
<column name="MaintLogID1">BRMR35021175</column>
</row>
<row>
<column name="Notes">work completed as per pm, moisture indicators
arrived ane have been fitted the residual pressure i in the towers is
within limits
and the differential pressure across the pre and after fillers is
satisfactory, operation of auto condensate drains is satisfactory </column>
<column name="MaintLogID1">BRMR35021176</column>
</row>
<row>
<column name="Notes">work completed as per pm, the moisure
indicator arrived are have been fitted, the residual pressure in the towers
is satisfactory
the differential presure across the pre and after filter is satisfactory
and the operation of the auto condensate drains is
satisfactory </column>
<column name="MaintLogID1">BRMR35021177</column>
</row>
<row>
<column name="Notes">work completed as per pm, an internal and
external inspection of the fire extinguishers was made and all was found
to be
satisfactory rupture disc checked ok Co2 cyl weight ok.</column>
<column name="MaintLogID1">BRMR35021178</column>
</row>
<row>
<column name="Notes">Completed and filed.</column>
<column name="MaintLogID1">BRMR35021179</column>
</row>
<row>
<column name="Notes">Alarm Functioning Correctly.
</column>
<column name="MaintLogID1">BRMR35021180</column>
</row>
<row>
<column name="Notes">All external lighting functioning.
</column>
<column name="MaintLogID1">BRMR35021181</column>
</row>
<row>
<column name="Notes">All indicators showing correct readings.
Linkages appear in good condition.
</column>
<column name="MaintLogID1">BRMR35021182</column>
</row>
<row>
<column name="Notes">All tests being caied out and recorded in the
GMDSS log book.
</column>
<column name="MaintLogID1">BRMR35021183</column>
</row>
<row>
<column name="Notes">Route MCP completed, heads satisfactory.
</column>
<column name="MaintLogID1">BRMR35021184</column>
</row>
<row>
<column name="Notes">Alarm Functioning Correctly.
</column>
<column name="MaintLogID1">BRMR35021185</column>
</row>
<row>
<column name="Notes">Alarm Functioning Correctly.
</column>
<column name="MaintLogID1">BRMR35021186</column>
</row>
<row>
<column name="Notes">No tool to carry out the PM.
Waiting for peak pressure gauge.</column>
<column name="MaintLogID1">BRMR35021187</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021188</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021189</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021190</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021191</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021192</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021193</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021194</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021195</column>
</row>
<row>
<column name="Notes">No defects observed</column>
<column name="MaintLogID1">BRMR35021196</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021197</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021198</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021199</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021200</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021201</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021202</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021203</column>
</row>
<row>
<column name="Notes">No defects observed. Recorded on weekly
routines sheet.</column>
<column name="MaintLogID1">BRMR35021204</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's. </column>
<column name="MaintLogID1">BRMR35021205</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's-Off load
test. </column>
<column name="MaintLogID1">BRMR35021206</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021207</column>
</row>
<row>
<column name="Notes">work completed as per pm compressors c/o no.3
is now running no.2 is in stby and no.1 is currently out of
service</column>
<column name="MaintLogID1">BRMR35021213</column>
</row>
<row>
<column name="Notes">work completed as per pm, all
satisfactory</column>
<column name="MaintLogID1">BRMR35021214</column>
</row>
<row>
<column name="Notes">work completed as per pm, oil levels checked
all satisfactory engine all satisfactory</column>
<column name="MaintLogID1">BRMR35021215</column>
</row>
<row>
<column name="Notes">work completed as per pm hoses tesed as per
rota all satisfactory. </column>
<column name="MaintLogID1">BRMR35021216</column>
</row>
<row>
<column name="Notes">work completed as per pm compressors c/o no.3
is now in use no.2 is in stby and no1 i is currently out of service,
operation
satisfactory.</column>
<column name="MaintLogID1">BRMR35021217</column>
</row>
<row>
<column name="Notes">work completed as per pmcompressors c/o no.3
is now in use operation satisfactory, no.2 is in stby and no.1 is currently
out of
service.</column>
<column name="MaintLogID1">BRMR35021218</column>
</row>
<row>
<column name="Notes">work completed as per pm oil levels checked
and found o.k. engine tested operation satisfactory shaft turned ahead and
astern</column>
<column name="MaintLogID1">BRMR35021219</column>
</row>
<row>
<column name="Notes">work completed as per pm, oil levels checked
and found satisfactory, engine tested operation satisfactory. shaft turned
ahead
and astern</column>
<column name="MaintLogID1">BRMR35021220</column>
</row>
<row>
<column name="Notes">work completed as per pm batteries charging
air bottles pressure checked and all satisfactory sprinkler system valves
operated
v belts ok </column>
<column name="MaintLogID1">BRMR35021221</column>
</row>
<row>
<column name="Notes">work completed as per pm batteries charging
air bottles pressure checked all satisfactory sprinkler system valves
opetated
condition of v belts ok.</column>
<column name="MaintLogID1">BRMR35021222</column>
</row>
<row>
<column name="Notes">work completed as per pm compressors c/o
operation satisfactory.</column>
<column name="MaintLogID1">BRMR35021223</column>
</row>
<row>
<column name="Notes">work completed as per pm compressors c/o
operation satisfactory</column>
<column name="MaintLogID1">BRMR35021224</column>
</row>
<row>
<column name="Notes">work completed as per om operation of valve
correct and alarm sounded</column>
<column name="MaintLogID1">BRMR35021225</column>
</row>
<row>
<column name="Notes">all flaps as per damper operated operation
satisfactory</column>
<column name="MaintLogID1">BRMR35021226</column>
</row>
<row>
<column name="Notes">work completed as per pm valve operation
correct and alarm operated</column>
<column name="MaintLogID1">BRMR35021227</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021228</column>
</row>
<row>
<column name="Notes">units c/o no.1 now in use operation
satisfactory</column>
<column name="MaintLogID1">BRMR35021229</column>
</row>
<row>
<column name="Notes">work completed as per pm units c/o no.1 unit
is now in use and operation is satisfactory</column>
<column name="MaintLogID1">BRMR35021230</column>
</row>
<row>
<column name="Notes">STP dosed as per pm</column>
<column name="MaintLogID1">BRMR35021231</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021232</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021233</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021234</column>
</row>
<row>
<column name="Notes">When I went too test the alarms and trips upon
opening the valves on the Compressor I noticed there was gas escaping from
The Braided Flexiable Pipe, on inspection it was found the pipe had split.
This split may have been caused by the vibration.
All valves were immediately reclosed. As no spares onboard a copper pipe
was fabricated
as in 3x360 degree coils to act as expanision coils and to help cope with
the vibration that takes place on the IGG plant skid.
Two brass sleeves also machined and fitted over the existing pipework and
new pipe/coil. The pipes were brazed in place and
and the system was then pressure tested. A full soapy water test also
carried out on the complete Refridgeration system
All appears to be in good order. The system was re-charged with R404 x (12)
bottles, Total man hours equals 70 hours.
Plant was run up on test and all working well. Alarms and trips PM was
carried and all alarms and trips functioned as required.
Lew McColl Cargo Eng. 02/10/2006
</column>
<column name="MaintLogID1">BRMR35021235</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021236</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021237</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021238</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021239</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021240</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021241</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021242</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021243</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021244</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021245</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021246</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021247</column>
</row>
<row>
<column name="Notes">All valves operated during testing of alarms
and trips</column>
<column name="MaintLogID1">BRMR35021248</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021249</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021250</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021251</column>
</row>
<row>
<column name="Notes">Air Heater inspected and found clean. No
problems to report.
Steam controller working satisfactorily, and drains all okay.</column>
<column name="MaintLogID1">BRMR35021252</column>
</row>
<row>
<column name="Notes">Air Heater inspected and found clean. No
problems to report.
Steam controller working satisfactorily, and drains all okay.</column>
<column name="MaintLogID1">BRMR35021253</column>
</row>
<row>
<column name="Notes">work completed as per pm the pump was removed
for inspection there was slight damage observed at the end part of the
stator
but overall the condition was good so all was reasembled and the packing
was replaced for new from spare gear shelf </column>
<column name="MaintLogID1">BRMR35021254</column>
</row>
<row>
<column name="Notes">work completed as per pm the vbelt were
checked all tensions appeared to be equal and tension was ok, the belts
were visually
checked and condition appears satisfactory, both pulleys were visually
inspected for any damage or cracks nothing unusual was
observed. an overall inspection was made inside the compressor and nothing
unusual was found no leaks were visible.
the water filter was cleaned 9736 hours 30/09/06.</column>
<column name="MaintLogID1">BRMR35021255</column>
</row>
<row>
<column name="Notes">Alarm tested and all in good order.</column>
<column name="MaintLogID1">BRMR35021256</column>
</row>
<row>
<column name="Notes">all valves as per pm operated and found
free</column>
<column name="MaintLogID1">BRMR35021258</column>
</row>
<row>
<column name="Notes">work completed as per pm port and starboard
alarms tested.</column>
<column name="MaintLogID1">BRMR35021259</column>
</row>
<row>
<column name="Notes">work completed as per pmalarm tested</column>
<column name="MaintLogID1">BRMR35021260</column>
</row>
<row>
<column name="Notes">work completed as per pm alarm tested
</column>
<column name="MaintLogID1">BRMR35021261</column>
</row>
<row>
<column name="Notes">work completed as per pm alarm tested</column>
<column name="MaintLogID1">BRMR35021262</column>
</row>
<row>
<column name="Notes">work completed as per pm alarm
tested.</column>
<column name="MaintLogID1">BRMR35021263</column>
</row>
<row>
<column name="Notes">Hours 8226.2
amps 1.15
fan inspected via cover no defects obseved, no abnormal noises when
running.</column>
<column name="MaintLogID1">BRMR35021264</column>
</row>
<row>
<column name="Notes">cleaned & operation observed no
defects</column>
<column name="MaintLogID1">BRMR35021265</column>
</row>
<row>
<column name="Notes">cleaned & operation observed no
defects</column>
<column name="MaintLogID1">BRMR35021266</column>
</row>
<row>
<column name="Notes">cleaned & operation observed no
defects</column>
<column name="MaintLogID1">BRMR35021267</column>
</row>
<row>
<column name="Notes">Elevator inspected no aditional infomation to
add to report of 2 month previous
Temp door oprning cable fitted to 4 deck (awaiting spares)</column>
<column name="MaintLogID1">BRMR35021268</column>
</row>
<row>
<column name="Notes">Fire Pump, Water Spray Pump, GS No1 and No2
Pumps: priming pumps checked. No leaks or abnormal
wear noticed. All moving parts greased. All pumps tested and ok. </column>
<column name="MaintLogID1">BRMR35021269</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
All alarms and trips tested and satisfactory.
ctr hrs: 1500.7
Some corrosion noted on unit body in earlier compartments this was removed
with a wire brush and coated.</column>
<column name="MaintLogID1">BRMR35021279</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021280</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021281</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021282</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021283</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021284</column>
</row>
<row>
<column name="Notes">Filter cleaned no defects observed.</column>
<column name="MaintLogID1">BRMR35021285</column>
</row>
<row>
<column name="Notes">All lines and fittings inspected no defects
observed</column>
<column name="MaintLogID1">BRMR35021286</column>
</row>
<row>
<column name="Notes">All lines and fittings inspected no defects
observed,
All safety equiptment checked and found to be in good order</column>
<column name="MaintLogID1">BRMR35021287</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021288</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021289</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021290</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021291</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021292</column>
</row>
<row>
<column name="Notes">Covers removed and unit cleaned out.
belts inspected
unit leak tested
all electrical connections checked.
evaporator inspected and found clear, drain line proved</column>
<column name="MaintLogID1">BRMR35021293</column>
</row>
<row>
<column name="Notes">Emergency D/Alt run on test on load for
approx. 15 minutes.
Main Switchboard Braker No2 Selected.
All ok. </column>
<column name="MaintLogID1">BRMR35021294</column>
</row>
<row>
<column name="Notes">Nil water found</column>
<column name="MaintLogID1">BRMR35021295</column>
</row>
<row>
<column name="Notes">Tested satisfactory, system flushed with fw on
completion.
Aft Hose reel station N2 Bottle Pressures = (1) 110, (2) 110 , (3) 110 ,
(4) 109 , (5) 109 Bar
Fwd Hose reel station N2 Bottle pressures = (1) 110 , (2) 111 , (3) 110 ,
(4) 110, (5) 110 Bar
Port manifold station N2 Bottle pressures = (1) 109 , (2) 110 , (3) 109 ,
(4) 109 , (5) 110 , (6) 109 , (7) 109 , (8) 108 Bar
Stbd manifold station N2 Bottle pressures = (1) 106 , (2) 110 , (3) 110 ,
(4) 109 , (5) 110 , (6) 109 , (7) 110 , (8) 110 Bar
All fixtures and fittings checked for condition and all in good order.
</column>
<column name="MaintLogID1">BRMR35021298</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021299</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
Boat's paddels need to be renewed-ongoing.
Rough weather recovery arrangment (shackles) renewed (cleaned, painted and
greased)
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021300</column>
</row>
<row>
<column name="Notes">System cabinet clean, all connections tight.
</column>
<column name="MaintLogID1">BRMR35021301</column>
</row>
<row>
<column name="Notes">Cabinet clean, all connections tight.
Earth bonding straps in good condition.
Shaft earthing ring cleaned.
</column>
<column name="MaintLogID1">BRMR35021302</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021303</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021304</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021305</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021306</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021307</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021308</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021309</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021310</column>
</row>
<row>
<column name="Notes">Motor windings 300 megogns to earth.
All connections secure, no signs of burning.
Contacts in good ciondition.
</column>
<column name="MaintLogID1">BRMR35021311</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021312</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021313</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021314</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021315</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021316</column>
</row>
<row>
<column name="Notes">Motor windings 300 megohms to earth.
</column>
<column name="MaintLogID1">BRMR35021317</column>
</row>
<row>
<column name="Notes">Both Joints on heater leaking therefore end
cover removed and also tube stack. All faces cleaned and new gaskets fitted
Please note that to remove the end covers and tube stack the relative pipe
work flanges has to be let go and the heater holding
down bolts removed. Leave one bolt in place and swing heater around a touch
by doing this the tube stack can the pass clear
Bye-pass valve support upright.
All lagging put back and heater pressure tested and all in good
order.</column>
<column name="MaintLogID1">BRMR35021318</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021319</column>
</row>
<row>
<column name="Notes">PM completed </column>
<column name="MaintLogID1">BRMR35021320</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021321</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021322</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021323</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021324</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021325</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021326</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021327</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021328</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021329</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021330</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021331</column>
</row>
<row>
<column name="Notes">Pm Completed</column>
<column name="MaintLogID1">BRMR35021332</column>
</row>
<row>
<column name="Notes">Tested from Gashouse to CCR</column>
<column name="MaintLogID1">BRMR35021333</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021334</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021335</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed. Stby pump this week</column>
<column name="MaintLogID1">BRMR35021336</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021337</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021338</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021339</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021340</column>
</row>
<row>
<column name="Notes">Recorded on routines sheet in log book, no
defects observed.</column>
<column name="MaintLogID1">BRMR35021341</column>
</row>
<row>
<column name="Notes">Operation of valves observed, Spindles
cleaned, all micro switches checked fot tightness, all soloniods
inspected</column>
<column name="MaintLogID1">BRMR35021342</column>
</row>
<row>
<column name="Notes">Operation of valves observed, Spindles
cleaned, all micro switches checked fot tightness, all soloniods
inspected</column>
<column name="MaintLogID1">BRMR35021343</column>
</row>
<row>
<column name="Notes">Flaps operated and reset </column>
<column name="MaintLogID1">BRMR35021344</column>
</row>
<row>
<column name="Notes">Alarm functional.
</column>
<column name="MaintLogID1">BRMR35021345</column>
</row>
<row>
<column name="Notes">Alarm functional.
</column>
<column name="MaintLogID1">BRMR35021346</column>
</row>
<row>
<column name="Notes">Motor removed to workshop and inspected no
defects observed</column>
<column name="MaintLogID1">BRMR35021347</column>
</row>
<row>
<column name="Notes">Alarm functional.
</column>
<column name="MaintLogID1">BRMR35021348</column>
</row>
<row>
<column name="Notes">All lighting operational.
Insulation reading satisfactory.
</column>
<column name="MaintLogID1">BRMR35021349</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021350</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021351</column>
</row>
<row>
<column name="Notes">Displays showing correct readings.
Linkages appear in good condition.
</column>
<column name="MaintLogID1">BRMR35021352</column>
</row>
<row>
<column name="Notes">Tests being carried out and recorded in the
GMDSS log book.
</column>
<column name="MaintLogID1">BRMR35021353</column>
</row>
<row>
<column name="Notes">Fire heads tested as per routes 1 and 2.
</column>
<column name="MaintLogID1">BRMR35021354</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021355</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021356</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021357</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021358</column>
</row>
<row>
<column name="Notes">no defects observed</column>
<column name="MaintLogID1">BRMR35021359</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021360</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021361</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021362</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021363</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021364</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021365</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021366</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021367</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021368</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021369</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021370</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021371</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021372</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021373</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.</column>
<column name="MaintLogID1">BRMR35021374</column>
</row>
<row>
<column name="Notes">alarm tested</column>
<column name="MaintLogID1">BRMR35021375</column>
</row>
<row>
<column name="Notes">work completed as per pm High air temperature
alarm tested operation satisfactory at 81 degrees.
the cut ins/out of machine tested all found to be as per pm the machine was
timed in pumping up the air pressure from 25 bar to
30 bar time taken was 17 mins and 50 seconds both the safety vavles were
removed and tested the lp v/v lifted as 8 bar and
the hp valve lifted at 31 bar the running of the compressor was found to be
satisfactory no leaks observed condition of air filter
is satisfactory.
</column>
<column name="MaintLogID1">BRMR35021376</column>
</row>
<row>
<column name="Notes">work completed as per pm the operation of the
high air temperature alarm and trip was operated and found satisfactory at
80
degrees the cut ins/outs of the machine was tested and found as per pm, the
time taken to pump the air pressure from 25 to
30 bar was found to take 18 mins 15 seconds. the safety valves were tesed
and the lp valve lifted at 8 bar and to hp valve lifted
at 31 bar. the operation of the machine was found to be satisfactory no
leaks were observed the condition of the air filter was
found to be satisfactory. hours 840.7 Date 06/10/06
</column>
<column name="MaintLogID1">BRMR35021377</column>
</row>
<row>
<column name="Notes">work completed as per pm battery cover removed
nothing unusual found no loose electrical connections found condition
of dynamo belt checked and found satisfactory sprinkler pump checked valve
operted</column>
<column name="MaintLogID1">BRMR35021378</column>
</row>
<row>
<column name="Notes">battery over removed nothing unusual found no
loose electrical connections found. condition and tension of dynamo belt
checked
all found satisfactory. sprinkler pump checked valve operated. </column>
<column name="MaintLogID1">BRMR35021379</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021380</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021381</column>
</row>
<row>
<column name="Notes">work completed as per pm all oil levels are
satisfactory operation of compressor satisfactory.</column>
<column name="MaintLogID1">BRMR35021382</column>
</row>
<row>
<column name="Notes">all oil levels checked all satisfactory engine
tested all satisfactory</column>
<column name="MaintLogID1">BRMR35021383</column>
</row>
<row>
<column name="Notes">all hoses tested as per rota nothing to
report</column>
<column name="MaintLogID1">BRMR35021384</column>
</row>
<row>
<column name="Notes">work completed as per pm,</column>
<column name="MaintLogID1">BRMR35021385</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021386</column>
</row>
<row>
<column name="Notes">work completed as per pm all oil levels
checked engine tested operation satisfactory</column>
<column name="MaintLogID1">BRMR35021387</column>
</row>
<row>
<column name="Notes">work completed as per pm all oil levels
checked engine tested operation satisfactory</column>
<column name="MaintLogID1">BRMR35021388</column>
</row>
<row>
<column name="Notes">work completed as per pm batteries checked
marking light ok all hatches free air cylinder pressure satisfactory
sprinkler
system ok valve operated.</column>
<column name="MaintLogID1">BRMR35021389</column>
</row>
<row>
<column name="Notes">work completed as per pm bateeries checked
marking light ok all hatches are free air cylinder pressure ok sprinkler
system is ok
valve operated.</column>
<column name="MaintLogID1">BRMR35021390</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021391</column>
</row>
<row>
<column name="Notes">work completed as per pm operation of
compressor satisfactory</column>
<column name="MaintLogID1">BRMR35021392</column>
</row>
<row>
<column name="Notes">work completed as per pm alarm tested no
calibration necessary</column>
<column name="MaintLogID1">BRMR35021393</column>
</row>
<row>
<column name="Notes">all dampers as per pm operated </column>
<column name="MaintLogID1">BRMR35021394</column>
</row>
<row>
<column name="Notes">work completed as per pm operation of alarm
and valve satisfactory</column>
<column name="MaintLogID1">BRMR35021395</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35021396</column>
</row>
<row>
<column name="Notes">work completed as per pm no.2 unit is now in
use operation is satisfactory</column>
<column name="MaintLogID1">BRMR35021397</column>
</row>
<row>
<column name="Notes">work completed as per pm no.2 unit is now in
use operation is satisfactory</column>
<column name="MaintLogID1">BRMR35021398</column>
</row>
<row>
<column name="Notes">system dosed as per pm</column>
<column name="MaintLogID1">BRMR35021399</column>
</row>
<row>
<column name="Notes">work completed as per pm all air inlets are
free</column>
<column name="MaintLogID1">BRMR35021400</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
DO filters cleaned, sludge dosing pump turned by hand and visually
inspected for leaks.
Flue gas fan bearing grease changed and belts tensions checked.
</column>
<column name="MaintLogID1">BRMR35021401</column>
</row>
<row>
<column name="Notes">In line with manufactures instructions, the
accumulator is operating correctly. Precharge is showing 0.9 mpa
looking back in history this value changes between around 1.1 - 0.6 on
the times it has been recorded
No action required to recharge.</column>
<column name="MaintLogID1">BRMR35021402</column>
</row>
<row>
<column name="Notes">In line with manufactures instructions, the
accumulator is operating correctly. Precharge is showing 0.9 mpa
looking back in history this value changes between around 1.1 - 0.6 on
the times it has been recorded
No action required to recharge.</column>
<column name="MaintLogID1">BRMR35021403</column>
</row>
<row>
<column name="Notes">Outbourd linkage on fan found to be damaged so
removed to workshop and made good
all moving parts lubricated
Bekt tension and allignment checked
suction pressure sensing lines proved clear</column>
<column name="MaintLogID1">BRMR35021404</column>
</row>
<row>
<column name="Notes">No carried out as per written
instructions</column>
<column name="MaintLogID1">BRMR35021405</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021406</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
Markings renewed.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021407</column>
</row>
<row>
<column name="Notes">Inspection completed as per PM.
All found satisfactory and ready for immediate use.
3/O T.B.</column>
<column name="MaintLogID1">BRMR35021408</column>
</row>
<row>
<column name="Notes">Tested as per pm routine:
One man bridge tested - alarms sounded satisfactorily.
Bridge watchcall tested to duty and all cabins.</column>
<column name="MaintLogID1">BRMR35021409</column>
</row>
<row>
<column name="Notes">Oil cooler end covers removed and tubes
brushed through. Anodes in good condition. Tubes in good condition.
Some slight corrosion and deposits evident on the end plates and pipework,
probably from the use of
sea water cooling in drydock.</column>
<column name="MaintLogID1">BRMR35021410</column>
</row>
<row>
<column name="Notes">Condenser inspected by removing inlet F W
pipe. Some slight corrosion evident in end cover and pipes,
probably due to using sea water cooling in drydock.</column>
<column name="MaintLogID1">BRMR35021411</column>
</row>
<row>
<column name="Notes">Breathaliser Calibrated using 0.35% BrAC
(0.08% BAC)
Sample taken and tested Satisfactorily.
Printer functioning correctly.
</column>
<column name="MaintLogID1">BRMR35021412</column>
</row>
<row>
<column name="Notes">Filter removed and cleaned , the filter was
due to be changed but as the machine has very few running hours it was not
deemed
necessary to change the filter at this time . Filter replaced after
cleaning and all put back. Machine ran up aqnd operated to
check for leaks all in good order</column>
<column name="MaintLogID1">BRMR35021413</column>
</row>
<row>
<column name="Notes">Filter removed and cleaned as there are few
running hours on machine not deemed necessary to replace filter.
Machine ran on test and all in good order</column>
<column name="MaintLogID1">BRMR35021414</column>
</row>
<row>
<column name="Notes">PM completed as per work order, All valves in
good condition and free moving . Exposed spindles on GI 701 greased as
required</column>
<column name="MaintLogID1">BRMR35021415</column>
</row>
<row>
<column name="Notes">Heater end cover removed as was the tube stack
all joint faces cleaned and new joints fitted to heater throughout.
Heater boxed up and pressure tested. All flanges re-tightened and all in
good order system put into service.</column>
<column name="MaintLogID1">BRMR35021421</column>
</row>
<row>
<column name="Notes">Hydralic oil tank level ok no water present.
Chain case oil level ok no water present.
Both oils appear in good condition.</column>
<column name="MaintLogID1">BRMR35021422</column>
</row>
<row>
<column name="Notes">1st September, 2006. Starboard Stores
Crane. 0.4001.06
Not working on Remote, the hook would not go up or down, this is the same
with both remote control
units. Both these remote control units work satisfactorily on the Port
crane.
Checked the unit in C deck ECT, connections etc. Tested again and the
system is working fine.
Took readings when the crane working, these are on the drawings in D deck
Electronics Workshop.
I suspect the U5 speed control unit. The relays can be heard operating.
Keep an eye on this crane.
</column>
<column name="MaintLogID1">BRMR35021423</column>
</row>
<row>
<column name="Notes">2nd September, 2006. Crew Rice Boiler.
8.1200.00
Fuse blown, 1-A thermal fuse. No spare onboard so soldered a 10A fuse in
place.
The fuse is located in the base of the boiler. Ordered the correct fuse
from the UK.
</column>
<column name="MaintLogID1">BRMR35021424</column>
</row>
<row>
<column name="Notes">5th September, 2006. Incinerator.
8.0816.01
Fitted new Fuel Oil heater to the incinerator.
Test the thermostat and the safety cut out, all working correctly.
</column>
<column name="MaintLogID1">BRMR35021425</column>
</row>
<row>
<column name="Notes">5th September, 2006. No.2 Cargo
Switchboard. 6.0112.01
No.2 Cargo Machinery Room Exhaust Fan, breaker failed to reset after PM.
The breaker with not reset mechanically.
Replaced breaker, type Terasaki XH100NS, 3 phase, 75 Amps, FPM,
complete with Shunt Trip. Nil Rob, spare ordered. 6.0112.01.041.
</column>
<column name="MaintLogID1">BRMR35021426</column>
</row>
<row>
<column name="Notes">6th September, 2006. N2 Plant.
1.5600.11
Ref 4th July, 2006. The full modification carried out. Both plants now
operate in the correct manor,
as shown below.
Oxygen Alarms:-
Normal operation XY-2A Open XY-3A Closed
Oxygen High Alarm XY-2A Open XY-3A Closed
Oxygen High High Alarm XY-2A Closed XY-3A Open
On Oxygen High Alarm only the alarm sounds, the solenoids do not change.
D. Andrews 3/E
</column>
<column name="MaintLogID1">BRMR35021613</column>
</row>
<row>
<column name="Notes">Generator run up and put on load for 40
minutes. Log taken and filled when up to temperature, all OK.</column>
<column name="MaintLogID1">BRMR35021620</column>
</row>
<row>
<column name="Notes">Generator run up off load for 15 minutes, all
OK.</column>
<column name="MaintLogID1">BRMR35021621</column>
</row>
<row>
<column name="Notes">Emergency fire pump tested satisfactorily
using local electric start.</column>
<column name="MaintLogID1">BRMR35021622</column>
</row>
<row>
<column name="Notes">Checks carried out satisfactorily, bottle
pressures checked in conjunction with bottle valve defect PM. </column>
<column name="MaintLogID1">BRMR35021623</column>
</row>
<row>
<column name="Notes">Feed pump running as lead machine, machine not
changed over.</column>
<column name="MaintLogID1">BRMR35021624</column>
</row>
<row>
<column name="Notes">completed as per routine</column>
<column name="MaintLogID1">BRMR35021625</column>
</row>
<row>
<column name="Notes">completed as per routine</column>
<column name="MaintLogID1">BRMR35021627</column>
</row>
<row>
<column name="Notes">Awaiting replacement eye wash and disposable
gloves from LE West.</column>
<column name="MaintLogID1">BRMR35021629</column>
</row>
<row>
<column name="Notes">Wire run off and inspected, all ok. Not
greased at this time as still well lubricated.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35021660</column>
</row>
<row>
<column name="Notes">Coating in as new condition.
Nil sediment.
Vertical crack approx 500mm found in fwd bulkhead, upper level, iwo Port
Domestic tank.
Domestic tank drained to prevent further water loss to aft peak.
Domestic tank to be inspected asap.
Head office informed, repairs to be made at earliest oppurtunity.</column>
<column name="MaintLogID1">BRMR35021661</column>
</row>
<row>
<column name="Notes">Inspection completed. Life boat in good
condition, equipment and provisions in place and in date.
All ready for immediate use. Forward spring on aft david replaced.
G.B. 22/10/06</column>
<column name="MaintLogID1">BRMR35021662</column>
</row>
<row>
<column name="Notes">INSPECTION COMPLETED, ALL IN GOOD CONDITION,
IN DATE AND READY FOR IMMEDIATE USE.
FORWARD SPRING ON AFT DAVIT REPLACED.
22/10/06 G.B.</column>
<column name="MaintLogID1">BRMR35021663</column>
</row>
<row>
<column name="Notes">Inspection completed. All in good condition,
in date and ready for immediate use.
Forward spring on aft davit replaced.
22/10/06 G.B.</column>
<column name="MaintLogID1">BRMR35021664</column>
</row>
<row>
<column name="Notes">Inspection completed. All pyrotechnics in
place, in good condition and ready for immediate use.
22/10/06 G.B.</column>
<column name="MaintLogID1">BRMR35021665</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021666</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021667</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021668</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021669</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021670</column>
</row>
<row>
<column name="Notes">Inspection completed - all equipment in good
condition and ready for immediate use.
21/10/06 Bruzik 3/O</column>
<column name="MaintLogID1">BRMR35021671</column>
</row>
<row>
<column name="Notes">New pulleys and drive belts fitted. Compressor
running normally.</column>
<column name="MaintLogID1">BRMR35021672</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35021673</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35021674</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Engine room set faulty due to incorrect aligned microswitches - now OK.
Bridge set also faulty due to poorly designed layout. PCB being earthed by
dimmer potentiometer
- inserted plastic insultation piece, now OK.</column>
<column name="MaintLogID1">BRMR35021675</column>
</row>
<row>
<column name="Notes">PM completed ,fan mushroom vent removed and
impeller cleaned, as no sign of wear on motor bearings and motor running
amps
okay bearings not changed atthis time.</column>
<column name="MaintLogID1">BRMR35021676</column>
</row>
<row>
<column name="Notes">PM completed all in good order, new grease put
in gear drive</column>
<column name="MaintLogID1">BRMR35021677</column>
</row>
<row>
<column name="Notes">PM completed as per work order all in good
order new grease put in gear drive</column>
<column name="MaintLogID1">BRMR35021678</column>
</row>
<row>
<column name="Notes">PM completed, In the work instruction it says
to check drive belts, this is a direct drive fan. All other work completed
as per work order</column>
<column name="MaintLogID1">BRMR35021679</column>
</row>
<row>
<column name="Notes">This is a direct drive fan no sign of wear on
motor bearings and motor amps okay bearings not changed at this
time</column>
<column name="MaintLogID1">BRMR35021680</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35021681</column>
</row>
<row>
<column name="Notes">Filters cleaned,
framework inspected.
no defects observed</column>
<column name="MaintLogID1">BRMR35021682</column>
</row>
<row>
<column name="Notes">Filters cleaned,
framework inspected.
no defects observed</column>
<column name="MaintLogID1">BRMR35021683</column>
</row>
<row>
<column name="Notes">Filters cleaned,
framework inspected.
no defects observed</column>
<column name="MaintLogID1">BRMR35021684</column>
</row>
<row>
<column name="Notes">Filters cleaned,
framework inspected.
no defects observed</column>
<column name="MaintLogID1">BRMR35021685</column>
</row>
<row>
<column name="Notes">Sight glass still clear so no sample taken.
All valves /guages /and fittings inspected no defects observed.
leak test carriedout on entire system with teat meter and soapy water.
NB For motor room ,duct keel and port under passage way fans carry out
checks through small inspection panel on trunking
These fans should be overhauled during next repair period.
Fan inspected as above and all in good order no visible movement observed
in motor bearings , no visible cracks on fan impeller
With fan running no noises or vibration noticed
Fan running AMPS = 5.6 amp. Fan damper free to move full travel of spindle.
</column>
<column name="MaintLogID1">BRMR35021848</column>
</row>
<row>
<column name="Notes">Alarm tested and all in good order</column>
<column name="MaintLogID1">BRMR35021849</column>
</row>
<row>
<column name="Notes">PM completed as per work order, all funtions
tested and all okay</column>
<column name="MaintLogID1">BRMR35021850</column>
</row>
<row>
<column name="Notes">Lub oil pumps stopped and breaker and fues
removed . Both filters removed and checked for dirt etc!. Filters appeared
to be in
clean condition . Both filters blown through with compressed air and
replaced.
Lub oil pump fuse and breaker put in and pumps started filters primed and
checked for leaks.
All in good order.</column>
<column name="MaintLogID1">BRMR35021851</column>
</row>
<row>
<column name="Notes">Lub oli piump isolated and fuses removed ,
filters removed and cleaned no debris found and all returned to normal
running condition</column>
<column name="MaintLogID1">BRMR35021852</column>
</row>
<row>
<column name="Notes">PM completed , All Slewing rim bolts checked
for tightness using hammer test method, all in good order and no bolts
found slack
As exposed threads are protected by DENSO tape this was replaced as and
were required.</column>
<column name="MaintLogID1">BRMR35021853</column>
</row>
<row>
<column name="Notes">PM completed as per work order Instrument No
10233 , sensor No A2-39-72 calibrated okay and results entered into QAP05
Instument No 13002 ,sensor No A2-3510 calibrated but failed to register
correct dew point compared to other instrument.
This I nstrument is to be returned to the makers for inspection and
repair.</column>
<column name="MaintLogID1">BRMR35021854</column>
</row>
<row>
<column name="Notes">No. 2 machine the duty machine at present.
Not changed over.</column>
<column name="MaintLogID1">BRMR35021855</column>
</row>
<row>
<column name="Notes">No. 2 machine duty, No. 1 run up along with 2
satisfactorily.</column>
<column name="MaintLogID1">BRMR35021856</column>
</row>
<row>
<column name="Notes">Fire pump test run satisfactorily. Start
tested from bridge position.</column>
<column name="MaintLogID1">BRMR35021857</column>
</row>
<row>
<column name="Notes">One man bridge alarm and watch call tested as
per PM and satisfactorily.</column>
<column name="MaintLogID1">BRMR35021858</column>
</row>
<row>
<column name="Notes">PM completed fan inspected through the side
cover ,no play noticed on bearings</column>
<column name="MaintLogID1">BRMR35021859</column>
</row>
<row>
<column name="Notes">PM completed as per work order, all in good
order</column>
<column name="MaintLogID1">BRMR35021860</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35021861</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021862</column>
</row>
<row>
<column name="Notes">PM completed all in good order</column>
<column name="MaintLogID1">BRMR35021863</column>
</row>
<row>
<column name="Notes">PM completed as per work order all in good
order</column>
<column name="MaintLogID1">BRMR35021864</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021865</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021866</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021867</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021868</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021869</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021870</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021871</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021872</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021873</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021874</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021875</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35021876</column>
</row>
<row>
<column name="Notes">Tested from ccr to Machine room loud and
clear</column>
<column name="MaintLogID1">BRMR35021877</column>
</row>
<row>
<column name="Notes">Glycol heater leaking steam side and glycol
side . Heater drained of glycol and tube stack removed . All faces cleaned
up.
New joints fitted through out. All in good order now</column>
<column name="MaintLogID1">BRMR35021878</column>
</row>
<row>
<column name="Notes">Work order completed as per job description .
System recharged 12 bottles 404 ? . System checked for leaks and none found
compressor
run on test and all in good order</column>
<column name="MaintLogID1">BRMR35021879</column>
</row>
<row>
<column name="Notes">Pump run on full load during power restoration
after blackout. Pump operated satisfactorily, with a discharge pressure
maintained between 80 and 90 bar.</column>
<column name="MaintLogID1">BRMR35021880</column>
</row>
<row>
<column name="Notes">T/A L.O duplex changed over, filter removed
and inspected, found to be spotless.</column>
<column name="MaintLogID1">BRMR35021881</column>
</row>
<row>
<column name="Notes">Feed pump greasing routine completed OK,
quantity of old grease removed from around nut.</column>
<column name="MaintLogID1">BRMR35021882</column>
</row>
<row>
<column name="Notes">PM completed over a 2 day period.
All valves removed and thourghly inspected all still in a new condition, no
signs of any wear or damage to "O rings" and
valve disc's. Valves returned and tested for free movement and
closure all in good order.
The valves are not that difficult to remove from in between the flanges but
to make life a bit easier I used 2 pieces of M16
screwed rod and nuts placing between flanges to act as flange splitters
method worked okay. I did not remove all the bolts from the flanges
Valves lifted up and lowered to deck level for inspection. Greased were
necessary.</column>
<column name="MaintLogID1">BRMR35021883</column>
</row>
<row>
<column name="Notes">PM completed as per work order , all valves
operated full range freely, no degects found</column>
<column name="MaintLogID1">BRMR35021884</column>
</row>
<row>
<column name="Notes">high level alarm tested </column>
<column name="MaintLogID1">BRMR35021885</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021886</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021887</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021888</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021889</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021890</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021891</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021892</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021893</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021894</column>
</row>
<row>
<column name="Notes">high level alarm tested</column>
<column name="MaintLogID1">BRMR35021895</column>
</row>
<row>
<column name="Notes">Both AHU fully swept out and then sprayed, PM
carried out over 2 weeks to account for the weekly changeover of
the units.</column>
<column name="MaintLogID1">BRMR35021896</column>
</row>
<row>
<column name="Notes">PM completed all ok</column>
<column name="MaintLogID1">BRMR35021952</column>
</row>
<row>
<column name="Notes">PM completed as described in work order all
ok</column>
<column name="MaintLogID1">BRMR35021953</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35021954</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35021955</column>
</row>
<row>
<column name="Notes">PM completed as per work order amps= 5.6
amps</column>
<column name="MaintLogID1">BRMR35021956</column>
</row>
<row>
<column name="Notes">PM completed as per work order amps = 7.3
amps</column>
<column name="MaintLogID1">BRMR35021957</column>
</row>
<row>
<column name="Notes">PM completed as per work order amps= 16.5
amps</column>
<column name="MaintLogID1">BRMR35021958</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
Operation of cut in/out satisfactory.
Alarms and trips tested:
High temeprature: 105 deg alarm
110 deg trip
High cooling water temperature: 65 deg Alarm
Emergency stop tested and satisfactory.
Operation of low air receiver pressure tested and satisfactory.
running hrs:10190</column>
<column name="MaintLogID1">BRMR35021959</column>
</row>
<row>
<column name="Notes">Routine completed. Line tested to 7.5 Bar. No
defects found.
Jib wire guides fitted with rubber hose to prevent chafing of new
wire.</column>
<column name="MaintLogID1">BRMR35022005</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022006</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022007</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Phone to bridge/motor room is audible but not brilliant.
Main auto telephone satisfactory.</column>
<column name="MaintLogID1">BRMR35022008</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Readings satisfactory.</column>
<column name="MaintLogID1">BRMR35022009</column>
</row>
<row>
<column name="Notes">Alarm tested and proved operational</column>
<column name="MaintLogID1">BRMR35022010</column>
</row>
<row>
<column name="Notes">All lightsticks found to be present in all
locations and in date.</column>
<column name="MaintLogID1">BRMR35022011</column>
</row>
<row>
<column name="Notes">All life buoys checked as per PM. All found to
be in good condition ready for immeadiate use.</column>
<column name="MaintLogID1">BRMR35022012</column>
</row>
<row>
<column name="Notes">Test carried out with leak detector and soapy
water</column>
<column name="MaintLogID1">BRMR35022013</column>
</row>
<row>
<column name="Notes">Running unit leak tested with meter and soapy
water
All rooms inspected evaporators brushed down</column>
<column name="MaintLogID1">BRMR35022014</column>
</row>
<row>
<column name="Notes">Pump ran on test through aux
condenser</column>
<column name="MaintLogID1">BRMR35022015</column>
</row>
<row>
<column name="Notes">Flushed</column>
<column name="MaintLogID1">BRMR35022016</column>
</row>
<row>
<column name="Notes">Inspected no defects observed</column>
<column name="MaintLogID1">BRMR35022017</column>
</row>
<row>
<column name="Notes">Tested no defects</column>
<column name="MaintLogID1">BRMR35022018</column>
</row>
<row>
<column name="Notes">leak tests carried out with soap and
meter</column>
<column name="MaintLogID1">BRMR35022019</column>
</row>
<row>
<column name="Notes">Engineers call tested 11/11/06
patrolman time out tested </column>
<column name="MaintLogID1">BRMR35022020</column>
</row>
<row>
<column name="Notes">Operated</column>
<column name="MaintLogID1">BRMR35022021</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35022022</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35022023</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35022024</column>
</row>
<row>
<column name="Notes">Greased</column>
<column name="MaintLogID1">BRMR35022025</column>
</row>
<row>
<column name="Notes">Cleaned and inspected</column>
<column name="MaintLogID1">BRMR35022026</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35022027</column>
</row>
<row>
<column name="Notes">Stretchers inspected and found to be in good
condition. all accessories for paraguard in good condition.
New Robinson stretcher, old one to be used for drill purposes
only.</column>
<column name="MaintLogID1">BRMR35022028</column>
</row>
<row>
<column name="Notes">International shore connection inspected as
per PM all found to be in good condition and ready for immeadiate
use.</column>
<column name="MaintLogID1">BRMR35022029</column>
</row>
<row>
<column name="Notes">Emergency diesel on load for approx 15minutes
after total loss of electrical power morning of the 8th Nov 2006. Diesel
cut in and put itself on load without problem and ran satisfactorily whilst
on load.</column>
<column name="MaintLogID1">BRMR35022030</column>
</row>
<row>
<column name="Notes">Emergency diesel ran on load morning of the
8th November 2006 during blackout conditions,
diesel started and put itself on load without problem.</column>
<column name="MaintLogID1">BRMR35022031</column>
</row>
<row>
<column name="Notes">Standby generator run on load without problem.
Log sheet filed in ECR.</column>
<column name="MaintLogID1">BRMR35022032</column>
</row>
<row>
<column name="Notes">Hot FW circ pump tripped on overload and found
to be seized evening of the 9th November. Pump and motor stripped down,
Large quantity of string (?) found wrapped around the motor fan, and non
drive end motor bearing found seized solid.
Both bearings changed.
Pump was opened up as some play in shaft was observed. Pump casing heavily
chocked with scale but no apparent damage
found. Wear rings in good condition. The collar between the pump casing
and the mechanical seal was observed to be quite
heavily corroded at this time. Pump impellor, shafting and mechanical seal
observed to be in good condition and so returned to
service.
Pump test run satisfactorily. Running amps 1.2/1.3 </column>
<column name="MaintLogID1">BRMR35022033</column>
</row>
<row>
<column name="Notes">All valves operated satisfactory
Pressure alarm tested</column>
<column name="MaintLogID1">BRMR35022034</column>
</row>
<row>
<column name="Notes">All equipment present and as new, stored in
Deck Trunk store.</column>
<column name="MaintLogID1">BRMR35022035</column>
</row>
<row>
<column name="Notes">PM completed as per work order all exposed
spindles greased and manual valves operated full range of travel.
No defects to report all in good order.
</column>
<column name="MaintLogID1">BRMR35022036</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Routes 11 and 12 completed.</column>
<column name="MaintLogID1">BRMR35022037</column>
</row>
<row>
<column name="Notes">Work completed as per pm hoses tested as per
rota </column>
<column name="MaintLogID1">BRMR35022038</column>
</row>
<row>
<column name="Notes">work completed as per pm engine tested no
problems engine oil and fuel oil levels satisfactory.</column>
<column name="MaintLogID1">BRMR35022039</column>
</row>
<row>
<column name="Notes">operation of drains tank oil monitor alarm
tested operation of alarm and valve satisfactory.</column>
<column name="MaintLogID1">BRMR35022040</column>
</row>
<row>
<column name="Notes">work completed as per pm operation of bilge
oil monitor tested and found to be satisfactory. </column>
<column name="MaintLogID1">BRMR35022041</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35022042</column>
</row>
<row>
<column name="Notes">work completed as per pm no.1 compressor
running operation satisfactory, no.2 in stby</column>
<column name="MaintLogID1">BRMR35022043</column>
</row>
<row>
<column name="Notes">work completed as per pm all oil levels
satisfactory operation of compressor satisfactory.</column>
<column name="MaintLogID1">BRMR35022044</column>
</row>
<row>
<column name="Notes">work completed as per pmno.1 compressor
running operation satisfactory no.2 in stby.</column>
<column name="MaintLogID1">BRMR35022045</column>
</row>
<row>
<column name="Notes">work completed as per pm no.1 compressor
running operation satisfactory no.2 in stby </column>
<column name="MaintLogID1">BRMR35022046</column>
</row>
<row>
<column name="Notes">work completed as per pm operation of
compressor satisfactory</column>
<column name="MaintLogID1">BRMR35022047</column>
</row>
<row>
<column name="Notes">work completed as per pm operation of
compressor satisfactory.</column>
<column name="MaintLogID1">BRMR35022048</column>
</row>
<row>
<column name="Notes">work completed as per pm</column>
<column name="MaintLogID1">BRMR35022049</column>
</row>
<row>
<column name="Notes">work completed as per pm no.1 unit is in use
operation of drier satisfactory</column>
<column name="MaintLogID1">BRMR35022050</column>
</row>
<row>
<column name="Notes">work completed as per pm no.1 drier in use
operation satisfactory.</column>
<column name="MaintLogID1">BRMR35022051</column>
</row>
<row>
<column name="Notes">system dosed as per pm</column>
<column name="MaintLogID1">BRMR35022052</column>
</row>
<row>
<column name="Notes">work completed as per pm.</column>
<column name="MaintLogID1">BRMR35022053</column>
</row>
<row>
<column name="Notes">Calibrated and tested with 0.08% BAC gas and
printed results with new ABLE printer.
All results okay, printer working very clearly.</column>
<column name="MaintLogID1">BRMR35022054</column>
</row>
<row>
<column name="Notes">One man Bridge Alarm tested. Watch Call tested
to Duty and all nav officer cabins.
Alarm timer and all alarms sounded correctly.</column>
<column name="MaintLogID1">BRMR35022055</column>
</row>
<row>
<column name="Notes">Rescue boat inspected as per PM. Boat found to
be in good condition ready for immeadiate use.
all loose equipment checked all present and found in good condition.
</column>
<column name="MaintLogID1">BRMR35022056</column>
</row>
<row>
<column name="Notes">All immersion suits checked all found to be in
very good condition.
All immersion suits in bags and not hung up as per PM.</column>
<column name="MaintLogID1">BRMR35022057</column>
</row>
<row>
<column name="Notes">PM completed as per work order all in good
order</column>
<column name="MaintLogID1">BRMR35022058</column>
</row>
<row>
<column name="Notes">Vents drained weekly as part of C/O saturday
routines</column>
<column name="MaintLogID1">BRMR35022059</column>
</row>
<row>
<column name="Notes">All sets checked and OK.</column>
<column name="MaintLogID1">BRMR35022060</column>
</row>
<row>
<column name="Notes">Valves operated, no problems.</column>
<column name="MaintLogID1">BRMR35022061</column>
</row>
<row>
<column name="Notes">System salinometer's checked- ADT, auxy
condenser and main condenser probes all OK.
Dearator salinometer was reading 21ppm (Full scale) during use. When
removed it was observed to be quite dirty, and wouldn't
clean off easily. It was replaced with a new probe off the shelf which
read fine straight away. </column>
<column name="MaintLogID1">BRMR35022062</column>
</row>
<row>
<column name="Notes">The vacuumator pump was replaced for the spare
one on the 4th deck due a leak observed under the running pump comming
from the tell tale hole the mechanical seal had failed the faulty pump was
rebuilt with the leaking seal so it could be used in
an emergency until which time spares arrived. spares were ordered at this
time.</column>
<column name="MaintLogID1">BRMR35022063</column>
</row>
<row>
<column name="Notes">PM completed as per work order, this fan is
the swing out type. Impeller inspected for signs of cracking etc! and is in
good order
The fan was in a clean condition all fixtures and fittings checked and
found to be secure. There was no axial movement apparent
on the motor bearings . Fan boxed up and run on test Amps when running =
8.5 amps.</column>
<column name="MaintLogID1">BRMR35022064</column>
</row>
<row>
<column name="Notes">work completed as per pm residual pressure
satisfactory, moisture indicators observed to be indicating a deep green
colour
differential pressure across the pre and after filter observed to be
satisfactory
operation of automatic drains satisfactory.
</column>
<column name="MaintLogID1">BRMR35022065</column>
</row>
<row>
<column name="Notes">work completed as per pm residual pressure
satisfactory, moisture indicators observed to be a deep green colour
differential pressure across pre and after filter satisfactory operation of
auto condensate drain satisfactory</column>
<column name="MaintLogID1">BRMR35022066</column>
</row>
<row>
<column name="Notes">PM completed as per work order heater
insulation measured and all good.
Fan opened up for inspection impeller checked for signs of cracking and all
appears to be in good order.
All boxed up and fan ran on test no defects to report this period.</column>
<column name="MaintLogID1">BRMR35022067</column>
</row>
<row>
<column name="Notes">work completed as per pm the 3 seperators were
replaced and the oil filter was also replaced. the old oil was drained out
of the compressor and replaced with a full charge of fresh oil the
compressor safety valve was also tested at this time.
the compressor was run after maintenance operation was satisfactory. no
leaks were observed.</column>
<column name="MaintLogID1">BRMR35022068</column>
</row>
<row>
<column name="Notes">this pm was completed in conjunction with work
order MER/06/03438 the safety valve was tested and put back on
compressor the compressor was run up all was satisfactory no leaks was
observed, however on the 21/10/06 this safety was
was observed to be passing it was removed and adjusted however it was still
observed to be passing when tested the valve seat
was checked and cleaned as best possible but valve was still passing. the
safety valve from no.1 compressor which was out of
service at the time was tested observed to lift at 13.5 bar was fitted to
no.2 compressor the compressor was run up no leaks
were observed. no1 compressor was fittted with new safety valve when it was
put back into service after it was fitted with new
pulleys.</column>
<column name="MaintLogID1">BRMR35022069</column>
</row>
<row>
<column name="Notes">All CO2 fire extinguisher inspected and weight
checked.
Last survey valid till September 2008.
</column>
<column name="MaintLogID1">BRMR35022070</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
All grease points lubricated with high temperature greas.
</column>
<column name="MaintLogID1">BRMR35022071</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
Emergency manoeuvering valve tested in full length of operation ahead and
astern.</column>
<column name="MaintLogID1">BRMR35022072</column>
</row>
<row>
<column name="Notes">All alarms and trips operated satisfactory no
defects observed</column>
<column name="MaintLogID1">BRMR35022073</column>
</row>
<row>
<column name="Notes">alarms and trips operated satisfactory no
defects observed</column>
<column name="MaintLogID1">BRMR35022074</column>
</row>
<row>
<column name="Notes">Removed and visually inspected.
Trunking bottom inspected</column>
<column name="MaintLogID1">BRMR35022075</column>
</row>
<row>
<column name="Notes">Removed and visually inspected.
Trunking bottom inspected</column>
<column name="MaintLogID1">BRMR35022076</column>
</row>
<row>
<column name="Notes">Probe removed and cleaned
filter removed and cleaned (washed then dried out)
Zero check carried out</column>
<column name="MaintLogID1">BRMR35022077</column>
</row>
<row>
<column name="Notes">Probe removed and cleaned
filter removed and cleaned (washed then dried out)
Zero check carried out</column>
<column name="MaintLogID1">BRMR35022078</column>
</row>
<row>
<column name="Notes">PM completed as per work order one defect to
report as in while testing sample line leaking on purge back inside
analysing
cabinet cause being slack union fitting made good. All other sample points
tested and good.
Sample lines from cofferdams and duct keel to be tested as and when
inspections fall due etc!.</column>
<column name="MaintLogID1">BRMR35022079</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Brushes in good condition.
A small amount of oil is still contaminating ring and brushes. Suspect it
is the remanants of the old
oil leeching out from under the ring.
Ring and brushgear cleaned. </column>
<column name="MaintLogID1">BRMR35022080</column>
</row>
<row>
<column name="Notes">This is a repeat work order - see
MER/06/05239.</column>
<column name="MaintLogID1">BRMR35022081</column>
</row>
<row>
<column name="Notes">Filters removed and inspected, all found to be
spotless.</column>
<column name="MaintLogID1">BRMR35022082</column>
</row>
<row>
<column name="Notes">Filters removed and inspected, all found to be
spotless.</column>
<column name="MaintLogID1">BRMR35022083</column>
</row>
<row>
<column name="Notes">Pump was required to be run during maintenance
of another system, when started the seal of the suction filter blew out
so the pump was isolated and a new o-ring seal was fitted. Filter was
inspected at this time and found to be clean.
Some build up of deposits was noted on the magnetic portion of the
filter.</column>
<column name="MaintLogID1">BRMR35022084</column>
</row>
<row>
<column name="Notes">PM completed as per work order no defects to
report</column>
<column name="MaintLogID1">BRMR35022085</column>
</row>
<row>
<column name="Notes">PM completed as per work order all in good
order </column>
<column name="MaintLogID1">BRMR35022086</column>
</row>
<row>
<column name="Notes">PM completed as per work order all
okay</column>
<column name="MaintLogID1">BRMR35022087</column>
</row>
<row>
<column name="Notes">PM completed as per work order all
okay</column>
<column name="MaintLogID1">BRMR35022088</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Satisfactory operation.</column>
<column name="MaintLogID1">BRMR35022089</column>
</row>
<row>
<column name="Notes">All bilge strainers cleaned and valves
greased. </column>
<column name="MaintLogID1">BRMR35022090</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
All pneumatic fire flaps tested and ok. </column>
<column name="MaintLogID1">BRMR35022091</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Items completed where practical.</column>
<column name="MaintLogID1">BRMR35022092</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Items completed where practical. </column>
<column name="MaintLogID1">BRMR35022093</column>
</row>
<row>
<column name="Notes">no.1 cooler was put on line while no.2 cooler
was isloated and the filter was removed and cleaned, no2 cooler was
backflushed
, after no.2 cooler was put back on line, no.1 cooler was backflushed and
then isolated, pressure guages are not correct
there are some on order.</column>
<column name="MaintLogID1">BRMR35022094</column>
</row>
<row>
<column name="Notes">no.1 cooler was put on line while no.2 cooler
was isolated and the filter was removed and cleaned, no.2 cooler was also
backflushed at this time. no.2 cooler was then put back on line, no.1
cooler was backflushed and isolated.
pressure guages are not correct there are some on order. </column>
<column name="MaintLogID1">BRMR35022095</column>
</row>
<row>
<column name="Notes">work completed as per pmfuel, lub oil and
water lecvels all ok engine run on test operation satisfactory</column>
<column name="MaintLogID1">BRMR35022096</column>
</row>
<row>
<column name="Notes">work completed as per pm, fuel, water and lub
oil level satisfactory engine run on test shaft turned ahead and astern
operation
satisfactory. </column>
<column name="MaintLogID1">BRMR35022097</column>
</row>
<row>
<column name="Notes">Air bottles were pumped up to 200 bar,
sprinker valve operated free to move, condition of v belts satisfactory,
all equiptment
in order.</column>
<column name="MaintLogID1">BRMR35022098</column>
</row>
<row>
<column name="Notes">air cylinders pumped up to 200 bar, sprinkler
sea inlet valve operated found to be free no damage observed on v belts
all equiptment in order</column>
<column name="MaintLogID1">BRMR35022099</column>
</row>
<row>
<column name="Notes">work was completed as per pm, all part were
cleaned, the discs were observed to be clean no unusal sludge or deposits
were observed, all parts were examined nothing unusual was observed the
condition of bowl assembly was good no
abnormal waer was observed on the spindle, the height of the paring disc
was measured and found to be within limits as
per makers instructions, all the seals and orings were inspected their
condition was good no seals were replaced.
when the water was put on the purifier it was observed that the the bowl
closing water solenoid valve was passsing,
the rubber was perished again!! as there was no spares on board i had to
replce it with one from no.2 purifier.
there are 3 solenoid vales on order already as the last time i completed
this pm and shut off the water off the purifier,
when it went back on again the valve was passing the rubber was perished,
so this time i have ordered a solenoid valve kit, so
we can replace the perished rubber.
when the purifier was run up all operation was satisfactory, no abnomal
vibration was observed, the amps ok it was put through
a desludge cycle operation was satisfactory. the purifer was run for 24
hours all satisfactory </column>
<column name="MaintLogID1">BRMR35022100</column>
</row>
<row>
<column name="Notes">this pm was completed in conjunction with work
order MER/06/04787 the teeth of both the worm and the worm wheel were
inspected the condition of both was satisfactory the contact surfaces were
in good condition and the tooth profiles were
observed to be satisfactory. </column>
<column name="MaintLogID1">BRMR35022101</column>
</row>
<row>
<column name="Notes">work completed as per pm, work was completed
in conjunction with work oreder MER/06/04788 please check this history for
details as i mixed up pms when i was signing them off.
purifier was drained of old oil and refilled with 4 litres of fresh Enersyn
HTX 222 it was filled as per work order MER/06/04788</column>
<column name="MaintLogID1">BRMR35022102</column>
</row>
<row>
<column name="Notes">Work as per schedule.
All in good working order.</column>
<column name="MaintLogID1">BRMR35022103</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Tests being conducted and recorded in the GMDSS log book.</column>
<column name="MaintLogID1">BRMR35022104</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022105</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Forward - 12.99V
Aft - 12.99
Off Load</column>
<column name="MaintLogID1">BRMR35022106</column>
</row>
<row>
<column name="Notes">Work as per schedule.
1.
13.06 - 12.50V
2.
12.98 - 12.46V</column>
<column name="MaintLogID1">BRMR35022107</column>
</row>
<row>
<column name="Notes">Work as per schedule.
1.
13.13 - 12.59V
2.
13.26 - 12.63V</column>
<column name="MaintLogID1">BRMR35022108</column>
</row>
<row>
<column name="Notes">All in good order</column>
<column name="MaintLogID1">BRMR35022109</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022110</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022111</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022112</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022113</column>
</row>
<row>
<column name="Notes">Tested from Machine room to CCR loud and
clear</column>
<column name="MaintLogID1">BRMR35022114</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022115</column>
</row>
<row>
<column name="Notes">All alarms tested okay.</column>
<column name="MaintLogID1">BRMR35022116</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022117</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022118</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022119</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022120</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022121</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022122</column>
</row>
<row>
<column name="Notes">Plant, lines and valves checked with meter and
soapy water</column>
<column name="MaintLogID1">BRMR35022123</column>
</row>
<row>
<column name="Notes">Plant, lines and valves checked with meter and
soapy water</column>
<column name="MaintLogID1">BRMR35022124</column>
</row>
<row>
<column name="Notes">Plant, lines and valves checked with meter and
soapy water</column>
<column name="MaintLogID1">BRMR35022125</column>
</row>
<row>
<column name="Notes">Condenser flushed stby pump this week</column>
<column name="MaintLogID1">BRMR35022126</column>
</row>
<row>
<column name="Notes">Flushed and inspected</column>
<column name="MaintLogID1">BRMR35022127</column>
</row>
<row>
<column name="Notes">All fixtures and fittings checked for
tightness</column>
<column name="MaintLogID1">BRMR35022128</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35022129</column>
</row>
<row>
<column name="Notes">Lubricated no defects</column>
<column name="MaintLogID1">BRMR35022130</column>
</row>
<row>
<column name="Notes">Lubricated no defects</column>
<column name="MaintLogID1">BRMR35022131</column>
</row>
<row>
<column name="Notes">Lubricated no defects</column>
<column name="MaintLogID1">BRMR35022132</column>
</row>
<row>
<column name="Notes">compleated</column>
<column name="MaintLogID1">BRMR35022133</column>
</row>
<row>
<column name="Notes">Inspected</column>
<column name="MaintLogID1">BRMR35022134</column>
</row>
<row>
<column name="Notes">Work carried out as per PM's.
Coolant, lub oil and fuel levels checked and engine run on test for about
10 minuts. </column>
<column name="MaintLogID1">BRMR35022135</column>
</row>
<row>
<column name="Notes">Fire fighting equipment spares checked and
AMOS updated. </column>
<column name="MaintLogID1">BRMR35022136</column>
</row>
<row>
<column name="Notes">Work carried out as per weekly routines.
15 ppm alarm tested and all satisfactory. </column>
<column name="MaintLogID1">BRMR35022137</column>
</row>
<row>
<column name="Notes">LPSG drain tank oil monitor alarm tested and
satisfactory. </column>
<column name="MaintLogID1">BRMR35022138</column>
</row>
<row>
<column name="Notes">Work as per schedule, except not connected to
supply to test.
2 lamps fitted and 3 spare.
Meggered at 100M+.</column>
<column name="MaintLogID1">BRMR35022139</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Cabinet opened up for inspection.
Visually OK except one fan found defective - to be ordered.
Cleaned where possible.</column>
<column name="MaintLogID1">BRMR35022140</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Cabinet opened up for inspection.
Fans OK but replacements to be ordered.
Cleaned where practical.</column>
<column name="MaintLogID1">BRMR35022141</column>
</row>
<row>
<column name="Notes">Probes tested satisfactorily. Solenoid valves
changed over OK and alarm sounded.</column>
<column name="MaintLogID1">BRMR35022142</column>
</row>
<row>
<column name="Notes">Probes tested OK, solenoid valves changed over
and alarm sounded OK.</column>
<column name="MaintLogID1">BRMR35022143</column>
</row>
<row>
<column name="Notes">Priming unit checked OK.</column>
<column name="MaintLogID1">BRMR35022144</column>
</row>
<row>
<column name="Notes">Priming unit checked OK.</column>
<column name="MaintLogID1">BRMR35022145</column>
</row>
<row>
<column name="Notes">Priming unit checked OK.</column>
<column name="MaintLogID1">BRMR35022146</column>
</row>
<row>
<column name="Notes">Priming unit checked OK.</column>
<column name="MaintLogID1">BRMR35022147</column>
</row>
<row>
<column name="Notes">Priming unit checked OK.</column>
<column name="MaintLogID1">BRMR35022148</column>
</row>
<row>
<column name="Notes">Stand By diesel test run on load OK. Log
sheets as per ECR hard copy.</column>
<column name="MaintLogID1">BRMR35022149</column>
</row>
<row>
<column name="Notes">Emergency diesel test run off load, air start
used.</column>
<column name="MaintLogID1">BRMR35022150</column>
</row>
<row>
<column name="Notes">Fire pump tested Ok. Local electric start
used.</column>
<column name="MaintLogID1">BRMR35022151</column>
</row>
<row>
<column name="Notes">Pump run up on test alongside no. 1 machine,
all OK.</column>
<column name="MaintLogID1">BRMR35022152</column>
</row>
<row>
<column name="Notes">Pump duty feed pump.</column>
<column name="MaintLogID1">BRMR35022153</column>
</row>
<row>
<column name="Notes">completed by maritronics
replacement of multizone pcb loop-c.
See report</column>
<column name="MaintLogID1">BRMR35022154</column>
</row>
<row>
<column name="Notes">completed by maritronics
Replacement of multizone pcb Loop-C
See report</column>
<column name="MaintLogID1">BRMR35022155</column>
</row>
<row>
<column name="Notes">completed by maritronics
replacement of multizone pcb Loop-C
See report</column>
<column name="MaintLogID1">BRMR35022156</column>
</row>
<row>
<column name="Notes">new bag received</column>
<column name="MaintLogID1">BRMR35022157</column>
</row>
<row>
<column name="Notes">PM completed as per work order
cn130 = 1.5 o2 lel = 0 cn 146 = 1.7 o2 lel =0, cn 126 = 1.7 o2, lel =
0</column>
<column name="MaintLogID1">BRMR35022158</column>
</row>
<row>
<column name="Notes">Resolved on board v/v lapped and proved
tight</column>
<column name="MaintLogID1">BRMR35022159</column>
</row>
<row>
<column name="Notes">PM completed as per work order, CN 230 o2=
1.5% LEL = 0, CN246 o2 = 1.6% LEL = 0%,
CN 226 o2 = 1.5% LEL = 0%, CN225 o2 = 1.5% LEL = 0%</column>
<column name="MaintLogID1">BRMR35022160</column>
</row>
<row>
<column name="Notes">PM COMPLETED AS PER WORK ORDER. CN 330 o2 =
1.5% LEL = 0%, CN346 o2 = 1.3% LEL = 0%
CN326 o2 = 1.6% LEL = 0% CN325 o2 = 1.5% LEL = 0%</column>
<column name="MaintLogID1">BRMR35022161</column>
</row>
<row>
<column name="Notes">PM COMPLETED AS PER WORK ORDER, CN430 o2 =
1.6% LEL= 0% CN446 o2 = 1.6% LEL = 0%
CN426 o2 = 1.6% LEL = 0% CN425 o2 = 1.5% LEL = 0%</column>
<column name="MaintLogID1">BRMR35022162</column>
</row>
<row>
<column name="Notes">312 313 293 295
309 309 298 298 230 230
231 230 102 99.3 103.2 100.6 240 240
99 99 All batteries
in good condition.
</column>
<column name="MaintLogID1">BRMR35022163</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Battery readings
Fwd - 12.60V
Mid - 12.60V
Mid - 12.63V
Aft - 12.58V
</column>
<column name="MaintLogID1">BRMR35022164</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022165</column>
</row>
<row>
<column name="Notes">parts received.
to be examined at docking & parts changed as required</column>
<column name="MaintLogID1">BRMR35022166</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Thruster unit swung 10deg Port and Stb'd; Press 1.2 and 1MPa
respectivly.
After several minutes of opepration temp of power pack motor was 35degC,
Pump was 50degC and the
v/v block was 40degC.
System oil was clear and bright, Hyd header tk low lvl alm tested.
</column>
<column name="MaintLogID1">BRMR35022317</column>
</row>
<row>
<column name="Notes">Done as part of 3 mounthly pm on same
date</column>
<column name="MaintLogID1">BRMR35022318</column>
</row>
<row>
<column name="Notes">All ER Fire dumpers tested and satisfactory.
</column>
<column name="MaintLogID1">BRMR35022319</column>
</row>
<row>
<column name="Notes">Electric whistle inspected and all found to be
ok. </column>
<column name="MaintLogID1">BRMR35022320</column>
</row>
<row>
<column name="Notes">Air whistle inspected and tested and all
satisfactory. </column>
<column name="MaintLogID1">BRMR35022321</column>
</row>
<row>
<column name="Notes">PM completed as per work order all in good
order
Accumulator bottle N2 press are Engine Room (1) = 8.8 mpa, (2) = 8.5 mpa,
(3) = 8.8mpa.
Accumulator</column>
<column name="MaintLogID1">BRMR35022322</column>
</row>
<row>
<column name="Notes">Diesel run on load during TA shutdown. Log as
per ECR hard copy. No problems identified.</column>
<column name="MaintLogID1">BRMR35022328</column>
</row>
<row>
<column name="Notes">Generator run of load after maintenance to
replace perished cooling water flexible hoses. All ok.</column>
<column name="MaintLogID1">BRMR35022329</column>
</row>
<row>
<column name="Notes">Pump test run ok using bridge start.</column>
<column name="MaintLogID1">BRMR35022330</column>
</row>
<row>
<column name="Notes">Valves operated Ok</column>
<column name="MaintLogID1">BRMR35022331</column>
</row>
<row>
<column name="Notes">Caba sets checked. Bottle 11 Serial number
2315 removed from service as no test certificate on board.
Valve used to replace incorrect valve on spare bottle which is now in
service.</column>
<column name="MaintLogID1">BRMR35022332</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35022333</column>
</row>
<row>
<column name="Notes">Latex gloves replaced. New small bottle of
Sterile Eye Solution placed in Kit.</column>
<column name="MaintLogID1">BRMR35022334</column>
</row>
<row>
<column name="Notes">All OK</column>
<column name="MaintLogID1">BRMR35022335</column>
</row>
<row>
<column name="Notes">Two bottles replaced that were
missing.</column>
<column name="MaintLogID1">BRMR35022336</column>
</row>
<row>
<column name="Notes">TESTED OK</column>
<column name="MaintLogID1">BRMR35022337</column>
</row>
<row>
<column name="Notes">All appears OK. Wires Greased last month.
Sheaves etc greased as part of monthly greasing routine.</column>
<column name="MaintLogID1">BRMR35022338</column>
</row>
<row>
<column name="Notes">All appears OK. Sheaves & blocks etc all
greased as part of monthly greasing routine. Wires greased last
month</column>
<column name="MaintLogID1">BRMR35022339</column>
</row>
<row>
<column name="Notes">All kit OK. All torches working
satisfactorily</column>
<column name="MaintLogID1">BRMR35022340</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022341</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022342</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Routes 16 and 17 completed.</column>
<column name="MaintLogID1">BRMR35022343</column>
</row>
<row>
<column name="Notes">Work as per schedule where practical.
Insulation Resistance Monitor indication showing extreme infintiy. Removed
meter and Monitor for calibration in workshop.
Adjustments made but when fitted in panel, showing same reading. Removed
again and re-calibrated. Now appears to be OK but
temperamental. Replacement to be ordered.
Several door securing bolts adjusted to fit.
Several superfluos cables need removing in the 220V section and some need
taping up.
The general condition of the switchboard is very dusty and needs to be
cleaned (this was not done in the previous dry-dock).
</column>
<column name="MaintLogID1">BRMR35022344</column>
</row>
<row>
<column name="Notes">Work as per schedule where practical.</column>
<column name="MaintLogID1">BRMR35022345</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022346</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Tests being conducted and recorded in the GMDSS log book.</column>
<column name="MaintLogID1">BRMR35022347</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022348</column>
</row>
<row>
<column name="Notes">Incinerator inspected, fan belts tensions
checked, refactory condition satisfactory.
Diesel and sludge burners found to be clean.
All moving parts lubricated.
Spark arrester found to be partialy dameged, spares on order. Temporary
repaired using
filter element.
Both cocks blocked and were removed and overhauled. Lines clear.
</column>
<column name="MaintLogID1">BRMR35022471</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022472</column>
</row>
<row>
<column name="Notes">Completed, no defects.
</column>
<column name="MaintLogID1">BRMR35022473</column>
</row>
<row>
<column name="Notes">Completed satisfactoroily, filter indicator in
the black, samples taken are clean. Gravity tank level is OK
& the low level alarm works fine.
</column>
<column name="MaintLogID1">BRMR35022474</column>
</row>
<row>
<column name="Notes">No reported problems and no leaks from
pneumatics or process.
</column>
<column name="MaintLogID1">BRMR35022475</column>
</row>
<row>
<column name="Notes">No reported problems and no leaks from
pneumatics or process.
</column>
<column name="MaintLogID1">BRMR35022476</column>
</row>
<row>
<column name="Notes">System checked satisfactorily.</column>
<column name="MaintLogID1">BRMR35022477</column>
</row>
<row>
<column name="Notes">FW system very clean, no corrosion or sludge.
</column>
<column name="MaintLogID1">BRMR35022478</column>
</row>
<row>
<column name="Notes">FW system very clean , co corrosion or sludge.
</column>
<column name="MaintLogID1">BRMR35022479</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35022480</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35022481</column>
</row>
<row>
<column name="Notes">Completed, no leaks belts adjusted.</column>
<column name="MaintLogID1">BRMR35022482</column>
</row>
<row>
<column name="Notes">Completed, no leaks belts adjusted.
</column>
<column name="MaintLogID1">BRMR35022483</column>
</row>
<row>
<column name="Notes">Feed pump greasing completed, old grease
removed.</column>
<column name="MaintLogID1">BRMR35022484</column>
</row>
<row>
<column name="Notes">Pump inspected OK, all holding down bolts
secure, mechanical seal not leaking and coupling in good condition.
Pump suction -0.3bar, discharge 1.6bar.</column>
<column name="MaintLogID1">BRMR35022485</column>
</row>
<row>
<column name="Notes">Pump inspected OK, all holding down bolts
secure, mechanical seal not leaking and coupling in good condition.
Pump suction -0.4bar, discharge 1.6 bar.</column>
<column name="MaintLogID1">BRMR35022486</column>
</row>
<row>
<column name="Notes">Completed , all in good order.
</column>
<column name="MaintLogID1">BRMR35022487</column>
</row>
<row>
<column name="Notes">Completed , all in good order.
</column>
<column name="MaintLogID1">BRMR35022488</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35022489</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35022490</column>
</row>
<row>
<column name="Notes">Completd, no defects.
</column>
<column name="MaintLogID1">BRMR35022491</column>
</row>
<row>
<column name="Notes">Completed, no defects.
</column>
<column name="MaintLogID1">BRMR35022492</column>
</row>
<row>
<column name="Notes">FW system clean & clear of
sludge.</column>
<column name="MaintLogID1">BRMR35022493</column>
</row>
<row>
<column name="Notes">FW system clean & clear of
sludge.</column>
<column name="MaintLogID1">BRMR35022494</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022495</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022496</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022497</column>
</row>
<row>
<column name="Notes">Cleaned.
</column>
<column name="MaintLogID1">BRMR35022498</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022499</column>
</row>
<row>
<column name="Notes">Cleaned.</column>
<column name="MaintLogID1">BRMR35022500</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022501</column>
</row>
<row>
<column name="Notes">Every is good.
</column>
<column name="MaintLogID1">BRMR35022502</column>
</row>
<row>
<column name="Notes">completed satisfactory</column>
<column name="MaintLogID1">BRMR35022503</column>
</row>
<row>
<column name="Notes">Every is good
</column>
<column name="MaintLogID1">BRMR35022504</column>
</row>
<row>
<column name="Notes">Sunday 3/12/06 Full back up tape sent via
melville agency Pt Fortin</column>
<column name="MaintLogID1">BRMR35022518</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022523</column>
</row>
<row>
<column name="Notes">PM completed all in good order.
These gauges were new in October 2006</column>
<column name="MaintLogID1">BRMR35022524</column>
</row>
<row>
<column name="Notes">PM completed as per work order all alarms and
shutdowns functioned as per requirements</column>
<column name="MaintLogID1">BRMR35022525</column>
</row>
<row>
<column name="Notes">PM completed as per work order</column>
<column name="MaintLogID1">BRMR35022526</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022527</column>
</row>
<row>
<column name="Notes">PM completed as per work order. there is a
component No conflict with this fan .
This Comp No =8.0519.01, the other No =7.1880.01.
Motor Amps = 5.7</column>
<column name="MaintLogID1">BRMR35022528</column>
</row>
<row>
<column name="Notes">PM completed as per work order Amps =
6.7</column>
<column name="MaintLogID1">BRMR35022529</column>
</row>
<row>
<column name="Notes">PM completed as per work order Amps =
16.8</column>
<column name="MaintLogID1">BRMR35022530</column>
</row>
<row>
<column name="Notes">PM completed as per work order
Amps= 4.9.</column>
<column name="MaintLogID1">BRMR35022531</column>
</row>
<row>
<column name="Notes">PM completed as per work order
Amps= 7.4</column>
<column name="MaintLogID1">BRMR35022532</column>
</row>
<row>
<column name="Notes">PM completed as per work order
Amps = 26</column>
<column name="MaintLogID1">BRMR35022533</column>
</row>
<row>
<column name="Notes">PM completed as per work order.
Amps= 4.8</column>
<column name="MaintLogID1">BRMR35022534</column>
</row>
<row>
<column name="Notes">PM completed as per work order.
Amps = 16.8</column>
<column name="MaintLogID1">BRMR35022535</column>
</row>
<row>
<column name="Notes">PM completed as per work order.
Amps = 26.</column>
<column name="MaintLogID1">BRMR35022536</column>
</row>
<row>
<column name="Notes">PM completed as per work order.
Amps = 7.4</column>
<column name="MaintLogID1">BRMR35022537</column>
</row>
<row>
<column name="Notes">New O2 cell fitted and calibrated all in good
order</column>
<column name="MaintLogID1">BRMR35022538</column>
</row>
<row>
<column name="Notes">PM completed new cell fitted and calibrated
all in good order.</column>
<column name="MaintLogID1">BRMR35022539</column>
</row>
<row>
<column name="Notes">PM completed </column>
<column name="MaintLogID1">BRMR35022540</column>
</row>
<row>
<column name="Notes">All screens clean and in good
condition.</column>
<column name="MaintLogID1">BRMR35022542</column>
</row>
<row>
<column name="Notes">All checked as per PM and found to be in good
condition. spare strecher kept in hospital used for drills only.</column>
<column name="MaintLogID1">BRMR35022547</column>
</row>
<row>
<column name="Notes">This pm done early as No 1 fan coupling failed
.
On inspection several of the coupling bolts were slack and signs of the end
of the rubber easing out of
place. All bolts slackened and coupling rubber/tyre (item 9 in spares book)
re-adjusted and positioned.
Spares order being placed 07/12/2006 for new couplings . Recommend this fan
be checked as and when
spares arrive with view to replacing.</column>
<column name="MaintLogID1">BRMR35022548</column>
</row>
<row>
<column name="Notes">PM completed all in good order</column>
<column name="MaintLogID1">BRMR35022549</column>
</row>
<row>
<column name="Notes">PM completed as per work order, All oils
changed and oil filter cleaned.
The condition of the filling and drain plugs are very poor and should be
changed out for stainless steel when these become
available order to be placed.
Also noted the condition of the Caphead Allen screws and pipe fittings in
very poor condition on winches etc!. </column>
<column name="MaintLogID1">BRMR35022550</column>
</row>
<row>
<column name="Notes">PM completed as per work order all valves free
to operate</column>
<column name="MaintLogID1">BRMR35022551</column>
</row>
<row>
<column name="Notes">Bridge watchcall and OMBO alarm tested. All
satisfactory.
Alarm panels checked in Capt, 2/O and 3/O cabins</column>
<column name="MaintLogID1">BRMR35022553</column>
</row>
<row>
<column name="Notes">PM completed as per pm all in good
order</column>
<column name="MaintLogID1">BRMR35022554</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022555</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022556</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022557</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022558</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022561</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022562</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022563</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022564</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022565</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022566</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022567</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022568</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022569</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022570</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Routes 20 and 21 completed.</column>
<column name="MaintLogID1">BRMR35022571</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022572</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Tests being conducted and recorded in the GMDSS log book.</column>
<column name="MaintLogID1">BRMR35022574</column>
</row>
<row>
<column name="Notes">Completed as per schedule.
Lighting on nightly during anchorage.</column>
<column name="MaintLogID1">BRMR35022575</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022576</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35022577</column>
</row>
<row>
<column name="Notes">PM completed, this is recorded weekly as part
of my routines and kept on file , file is printed out the end of the month
I take a print from the IS screen and also take a log from the unit on A
deck</column>
<column name="MaintLogID1">BRMR35022578</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022579</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35022580</column>
</row>
<row>
<column name="Notes">tested all okay</column>
<column name="MaintLogID1">BRMR35022581</column>
</row>
<row>
<column name="Notes">PM completed for RX415 instruments all units
calibrated as per manual and all good.
Awaiting proper flow regulator for testing the GX2001 units . Instruction
manual states that a flow meter of 0.5l/min
should be used. The only regulator we have that fits the 4 gas bottle is a
0.3l/min so therefore I am getting incorrect readings
for H2s etc!.</column>
<column name="MaintLogID1">BRMR35022582</column>
</row>
<row>
<column name="Notes">PM completed </column>
<column name="MaintLogID1">BRMR35022583</column>
</row>
<row>
<column name="Notes">8th December 2006 Stbd Boiler Forced Draft
Fan 5.0501.02
The stbd boiler was shut down for repairs, therefore the planned
maintenance for the fan motor was brought forward.
The starter was checked as per PM. Contacts checked and cleaned where
practical - in very good condition.
Parts cleaned where practical.
The motor terminal box was opened up for inspection and several problems
were found which must have originated from new.
One of the incomer phase cables had been cut too short with the result it
was rubbing on a sharp edge.
A cable tie had been fitted to prevent further damage. The cable gland for
that particular 3-core cable had unscrewed
completely and the cable was free to vibrate.
Remedial action :
À cut off bracket on cable duct to allow more movement in the cable.
À tighten gland lock ring.
À adjust phase cable so that it was away from sharp edge.
À fit packing under cables for added protection.
</column>
<column name="MaintLogID1">BRMR35022584</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022585</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022586</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022587</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022588</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022589</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022590</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35022591</column>
</row>
<row>
<column name="Notes">No.1 Compressor Prioity 3.</column>
<column name="MaintLogID1">BRMR35022592</column>
</row>
<row>
<column name="Notes">7th December 2006 No.3 Ballast Pump
4.1509.03
</column>
<column name="MaintLogID1">BRMR35022610</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022611</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022612</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022613</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022614</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022615</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35022616</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022617</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022618</column>
</row>
<row>
<column name="Notes">PM completed ,The ESD's on this PM are
covered over a 1/4ly period each point is tested and recorded as and when
it is done
Selected Points are tested when vessel is doing pre-loading/discharging
checks . The remainder not done as part of checks
are completed during the Quarter
</column>
<column name="MaintLogID1">BRMR35022619</column>
</row>
<row>
<column name="Notes">Completed.
</column>
<column name="MaintLogID1">BRMR35022620</column>
</row>
<row>
<column name="Notes">Gear Box Oil Level at Normal Working Level
Battery Condition Good.</column>
<column name="MaintLogID1">BRMR35022621</column>
</row>
<row>
<column name="Notes">Gearbox Oil Level at Normal Working Level
Battery Condition Good.</column>
<column name="MaintLogID1">BRMR35022622</column>
</row>
<row>
<column name="Notes">Burner removed, o/h burner fitted with new
teflon seal rings.
Done when Stb'd boiler shut down for maintenance.
</column>
<column name="MaintLogID1">BRMR35022623</column>
</row>
<row>
<column name="Notes">Burner removed, o/h burner fitted with new
teflon seal rings.
Done when Stb'd boiler shut down for maintenance.
</column>
<column name="MaintLogID1">BRMR35022624</column>
</row>
<row>
<column name="Notes">Burner removed, o/h burner fitted with new
teflon seal rings.
Done when Stb'd boiler shut down for maintenance.
</column>
<column name="MaintLogID1">BRMR35022625</column>
</row>
<row>
<column name="Notes">Completed during Boiler Shut Down.
All components found to be clean.</column>
<column name="MaintLogID1">BRMR35022626</column>
</row>
<row>
<column name="Notes">Completed, no problems observed.</column>
<column name="MaintLogID1">BRMR35022627</column>
</row>
<row>
<column name="Notes">Completed. No Problems observed.</column>
<column name="MaintLogID1">BRMR35022628</column>
</row>
<row>
<column name="Notes">Completed, No Problems observed.</column>
<column name="MaintLogID1">BRMR35022629</column>
</row>
<row>
<column name="Notes">Completed - No Problems observed. Air bottles
at 195 Bar.</column>
<column name="MaintLogID1">BRMR35022630</column>
</row>
<row>
<column name="Notes">Completed. All dampers operate
correctly.</column>
<column name="MaintLogID1">BRMR35022631</column>
</row>
<row>
<column name="Notes">1. Coupling disassembled, no excessive wear
detected.
2. Grease recherged as per 6000hr routine.
</column>
<column name="MaintLogID1">BRMR35022632</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35022633</column>
</row>
<row>
<column name="Notes">After leaking for some time the stb'd blr
was depressurised to facilitate the repair of the leaking drum
safety valve for'd.
The sealing faces were found wire drawn by the leaking steam IWO the drum
mounting stub and safety
v/v HP flange.
The resultant gouges were weld filled and dressed by hand file to affect a
gas tight seal.
The safety v/v was then remounted with new metalflex gaskets and returned
to service satisfactorily.
</column>
<column name="MaintLogID1">BRMR35022634</column>
</row>
<row>
<column name="Notes">PM completed all oils and greasing as
required</column>
<column name="MaintLogID1">BRMR35022635</column>
</row>
<row>
<column name="Notes">
11th December 2006 Boiler Fuel Oil System 5.1590.01
</column>
<column name="MaintLogID1">BRMR35022671</column>
</row>
<row>
<column name="Notes">Completed Satisfactorily.
</column>
<column name="MaintLogID1">BRMR35022672</column>
</row>
<row>
<column name="Notes">Completed satisfactorily.
</column>
<column name="MaintLogID1">BRMR35022673</column>
</row>
<row>
<column name="Notes">Completed satisfactorily.
</column>
<column name="MaintLogID1">BRMR35022674</column>
</row>
<row>
<column name="Notes">Port bridge wing space fine. Stbd bridge wing
- water had been leaking into the cpfferdam via the cable transit to the
bridge wing
helm/rev repeaters. Approximately 20 litres of water removed. Cofferdam
cleaned. Cable transit re-sealed with sealing compound.
</column>
<column name="MaintLogID1">BRMR35022675</column>
</row>
<row>
<column name="Notes">Ladder appears to be fine. Air in-line
lubricator topped up with oil.</column>
<column name="MaintLogID1">BRMR35022676</column>
</row>
<row>
<column name="Notes">Compressor Shut down and isolated (Air outlet,
cooling water inlet and outlet and breaker). All valves
lashed shut and breaker locked open with scafftag.
Oil level and quality checked. Level fine and oil slightly discoloured.
Oil drained.
Lube oil cooler drained and found to have oil in water side.
New Turbo Charger fitted due to impeller damage from disintegrating rubber
air filter.
Details in History.
Engine Oil Changed. Majority of oil syphoned out through dipstick tube.
Filter replaced.
Oil replenished with Vanellus C4.
Gear box oil drained and mesh filter removed and inspected. Some small
metal particles
observed and same seen in tray of used oil.
Oil replaced with Autran MBX.
Bunker Tank vents dismantled, balls and gauzes cleaned. Three rubber
gaskets missing of corroded, spares on order.
- Two HFO Settinling tanks stbd and port for'd bunker tank vent.
Conning Computers
ROS 2 computer found locked up causing failure of several inputs to update.
Both ROS 1 and ROS 2 computers rebooted and I/O circuits powered down. Now
OK.</column>
<column name="MaintLogID1">BRMR35022975</column>
</row>
<row>
<column name="Notes">Pressure transmitters tested with Jofre
throughout range. Very small deviation but linear on Press Trx.
Going a bit wider for the vacuum trx. at extreme vacuum only; Though
fine at normal working ranges.
Pulse lines all good. Transmitter isolator valve for MM236 needs to be
replaced. Seat corroded, needed
to shut V/V on P/P to retain test pressure.</column>
<column name="MaintLogID1">BRMR35022976</column>
</row>
<row>
<column name="Notes">Work order completed. Valve and vacuum
assembly removed opened up and found hole in float
Cleaned up and hole brazed up , float tested for leaks and all okay. Valve
opened up and overhauled
All boxed up and replaced system tested for leaks and fire main returned to
normal.</column>
<column name="MaintLogID1">BRMR35022977</column>
</row>
<row>
<column name="Notes">Completed as per workorder.
Very little left IWO anodes.
</column>
<column name="MaintLogID1">BRMR35022978</column>
</row>
<row>
<column name="Notes">Completed as per worksheet.
Very little left IWO Anodes.
</column>
<column name="MaintLogID1">BRMR35022979</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Operated satisfactorily.</column>
<column name="MaintLogID1">BRMR35022980</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Operated satisfactorily.</column>
<column name="MaintLogID1">BRMR35022981</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Battery readings
Fwd - 12.60V
Mid - 12.60V
Mid - 12.62V
Aft - 12.57V
</column>
<column name="MaintLogID1">BRMR35022982</column>
</row>
<row>
<column name="Notes">310 312 295 296
310 310 298 298 230 230
231 230 103.6 99.2 103.6 100.2 242 242
99.7 99 </column>
<column name="MaintLogID1">BRMR35022983</column>
</row>
<row>
<column name="Notes">TA alarms and trips tested, all operating at
setpoint and OK. As with No.1 TA, gland steam pressure alarm setpoint is
at -10kPa,
at which point main condenser vacuum is already dropping rapidly. All
other alarms and trips satisfactory.</column>
<column name="MaintLogID1">BRMR35022984</column>
</row>
<row>
<column name="Notes">Work as per schedule.
</column>
<column name="MaintLogID1">BRMR35022993</column>
</row>
<row>
<column name="Notes">Diesel run on load during ballasting
operations, log as per ECR hard copy, no problems noted. </column>
<column name="MaintLogID1">BRMR35022994</column>
</row>
<row>
<column name="Notes">Fire pump test run using local electric start.
No problems.</column>
<column name="MaintLogID1">BRMR35022995</column>
</row>
<row>
<column name="Notes">All sets checked and OK</column>
<column name="MaintLogID1">BRMR35022996</column>
</row>
<row>
<column name="Notes">Emergency diesel test run off load using local
electric start. No problems</column>
<column name="MaintLogID1">BRMR35022998</column>
</row>
<row>
<column name="Notes">Completed as per workorder.
</column>
<column name="MaintLogID1">BRMR35023006</column>
</row>
<row>
<column name="Notes">Completed as per workorder. Strainer opened
and cleaned.
</column>
<column name="MaintLogID1">BRMR35023007</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Meggered at 100M+.
Routes 25 + 26 completed.</column>
<column name="MaintLogID1">BRMR35023080</column>
</row>
<row>
<column name="Notes">Work as per schedule.
1.
13.26 - 12.73V
2.
13.14 - 12.65V</column>
<column name="MaintLogID1">BRMR35023112</column>
</row>
<row>
<column name="Notes">Work as per schedule.
1.
13.07 - 12.47
2.
13.03 - 12.43</column>
<column name="MaintLogID1">BRMR35023113</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Aft - 1300
Fwd - 1300</column>
<column name="MaintLogID1">BRMR35023114</column>
</row>
<row>
<column name="Notes">Work as per schedule.
All connections tight.
Contacts in good condition.</column>
<column name="MaintLogID1">BRMR35023115</column>
</row>
<row>
<column name="Notes">Work as per schedule.
The mains hum experienced with the normal power connected is also happening
on the Trader.
It is possible to reduce the hum by turning down the amplifier outputs.
This is not acceptable, therefore
the main power has been switched off and the system is now running on the
battery/mains.</column>
<column name="MaintLogID1">BRMR35023116</column>
</row>
<row>
<column name="Notes">Work as per schedule.
One speaker was found defective (trafo open circuit), the other had a
defective potentiometer.
It is not necessary to have two in the gymnasium (only one specified),
therefore one speaker has been
repaired and changed to maximum output - now OK.</column>
<column name="MaintLogID1">BRMR35023117</column>
</row>
<row>
<column name="Notes">PM Completed. Air regulator to be ordered due
to present one leaking.</column>
<column name="MaintLogID1">BRMR35023120</column>
</row>
<row>
<column name="Notes">All fluids levels checked and fine. Engine run
on test with no problems.</column>
<column name="MaintLogID1">BRMR35023121</column>
</row>
<row>
<column name="Notes">Fluid levels checked and all correct. Engine
run on test and fine.</column>
<column name="MaintLogID1">BRMR35023122</column>
</row>
<row>
<column name="Notes">Pm completed. All satisfactory.</column>
<column name="MaintLogID1">BRMR35023123</column>
</row>
<row>
<column name="Notes">Fluid levels checked and fine. Engine run on
test and satsifactory</column>
<column name="MaintLogID1">BRMR35023124</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Contacts in good condition.
Meggered at 100M+.</column>
<column name="MaintLogID1">BRMR35023126</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Contacts in good condition.
Meggered at 100M+.</column>
<column name="MaintLogID1">BRMR35023127</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Contacts in good condition.
Meggered at 100M+.</column>
<column name="MaintLogID1">BRMR35023128</column>
</row>
<row>
<column name="Notes">All 6kg and 12kg Dry Powder Extinguishers
opened for inspection.
CO2 cartridges removed and weighed - all at correct weights.
Powder delivery tubes cleared of compacted powder as required.
Sealing rings, piercing pins, mounting brackets checked and in good order.
Amos doesn't have these spares details, below are details from
packaging:
Details:
Unitor Article No. 667873
Headcap W/O Hose for P6P W Cartidge.
</column>
<column name="MaintLogID1">BRMR35023142</column>
</row>
<row>
<column name="Notes">Turning gear oil drained, unit flushed through
with new oil and sight glass cleaned. Oil replenished with approx 4 litres
GRXP100</column>
<column name="MaintLogID1">BRMR35023143</column>
</row>
<row>
<column name="Notes">Unit drained and flushed through with clean
oil, oil refilled NOT as per work as per instruction manual. 1100 cc GRXP
680
added with shaft at 30degrees from the horizontal. No excess oil observed
from filling point.</column>
<column name="MaintLogID1">BRMR35023144</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35023145</column>
</row>
<row>
<column name="Notes">Completed as per W.O. Suction vanes and links
dont work.
However manual ones work just fine.
</column>
<column name="MaintLogID1">BRMR35023146</column>
</row>
<row>
<column name="Notes">Completed as per W.O. Suction vanes and links
dont work.
However manual ones work just fine.</column>
<column name="MaintLogID1">BRMR35023147</column>
</row>
<row>
<column name="Notes">Completed as per WO. All Good.
</column>
<column name="MaintLogID1">BRMR35023148</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All Good.
</column>
<column name="MaintLogID1">BRMR35023149</column>
</row>
<row>
<column name="Notes">Completed as per W.O. Press = 0.95MPa.
</column>
<column name="MaintLogID1">BRMR35023150</column>
</row>
<row>
<column name="Notes">Completed as per W.O. Press = 0.9MPa.
</column>
<column name="MaintLogID1">BRMR35023151</column>
</row>
<row>
<column name="Notes">Completed as per Work Order. No Defects.
</column>
<column name="MaintLogID1">BRMR35023152</column>
</row>
<row>
<column name="Notes">Completed as per Work Order. No Defects.
</column>
<column name="MaintLogID1">BRMR35023153</column>
</row>
<row>
<column name="Notes">No.2 HFO Sett Tk Hi Level Pump Auto Stop
functioning correctly.</column>
<column name="MaintLogID1">BRMR35023154</column>
</row>
<row>
<column name="Notes">Dryer Checked. Dew Point Good (-86C), Filter
and column d.p.'s all fine</column>
<column name="MaintLogID1">BRMR35023155</column>
</row>
<row>
<column name="Notes">Dryer Checked. Dew Point Good (-88C), Filter
and column d.p.'s all fine</column>
<column name="MaintLogID1">BRMR35023156</column>
</row>
<row>
<column name="Notes">Purifier run up and put online on D/Gen Sump
for 24 hrs.
Low and high back pressure alarms and trips tested, Oil high
temp alarm tested and functioning correctly.
Sump level remained constant
Coating:
Generally in Good condition.
Mildew on coating on fore and aft bulkheads throughout. Some dust and dirt
under accesses from DD.
Bottom level on outboard bay- there is some detached loose paint on the
stripe coat.
However coating beneath is in near perfect condition.
Bottom level under rescue hatch - Some slight localised rust spots, but
coating generally intact and well
attached.
Coating:
Generally in Good condition.
Mildew on coating on fore and aft bulkheads throughout. Heavier dirt
concentrations on Stairwells probably due to being centre access
to Duct Keel during Dry Dock.
Coating appears to have been touched up in places, but is in good
condition.
</column>
<column name="MaintLogID1">BRMR35023197</column>
</row>
<row>
<column name="Notes">Fluid levels checked and fine. Engine R.O.T
with no problems.</column>
<column name="MaintLogID1">BRMR35023198</column>
</row>
<row>
<column name="Notes">Completed. Air bottles topped up to full. Now
reading 195bar.</column>
<column name="MaintLogID1">BRMR35023199</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023200</column>
</row>
<row>
<column name="Notes">Fluid levels checked. Engine R.O.T with no
problems</column>
<column name="MaintLogID1">BRMR35023201</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023202</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023203</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023204</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023205</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023206</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023207</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023208</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023209</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023210</column>
</row>
<row>
<column name="Notes">PM completed no defects</column>
<column name="MaintLogID1">BRMR35023211</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023212</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023213</column>
</row>
<row>
<column name="Notes">Alarm tested all okay</column>
<column name="MaintLogID1">BRMR35023214</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023215</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023216</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023217</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35023218</column>
</row>
<row>
<column name="Notes">Completed as per W.O.
</column>
<column name="MaintLogID1">BRMR35023219</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35023220</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35023221</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35023222</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35023223</column>
</row>
<row>
<column name="Notes">Completed. No defects to report</column>
<column name="MaintLogID1">BRMR35023224</column>
</row>
<row>
<column name="Notes">No.1 Dryer Shut Down</column>
<column name="MaintLogID1">BRMR35023225</column>
</row>
<row>
<column name="Notes">No.2 Air Dryer put into service, operating
correctly.</column>
<column name="MaintLogID1">BRMR35023226</column>
</row>
<row>
<column name="Notes">Completed. Operating correctly</column>
<column name="MaintLogID1">BRMR35023227</column>
</row>
<row>
<column name="Notes">Tested and operating correctly</column>
<column name="MaintLogID1">BRMR35023228</column>
</row>
<row>
<column name="Notes">Emergency DG test run off load using electric
start. No problems.</column>
<column name="MaintLogID1">BRMR35023234</column>
</row>
<row>
<column name="Notes">Stand by diesel run on load, log as per ECR
hard copy.</column>
<column name="MaintLogID1">BRMR35023236</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023237</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023238</column>
</row>
<row>
<column name="Notes">Work as per schedule.
All working satifactorily.</column>
<column name="MaintLogID1">BRMR35023239</column>
</row>
<row>
<column name="Notes">Work as per schedule.
All working satisfactorily.</column>
<column name="MaintLogID1">BRMR35023240</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Tests being conducted and recorded in the GMDSS log book.</column>
<column name="MaintLogID1">BRMR35023241</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023242</column>
</row>
<row>
<column name="Notes">PM completed all in good order</column>
<column name="MaintLogID1">BRMR35023243</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Routes 1 and 2 tested.</column>
<column name="MaintLogID1">BRMR35023244</column>
</row>
<row>
<column name="Notes">Burners all changed out and dirty cleaned and
ready for use.</column>
<column name="MaintLogID1">BRMR35023245</column>
</row>
<row>
<column name="Notes">Burners all changed out, dirty cleaned and
ready for use.</column>
<column name="MaintLogID1">BRMR35023246</column>
</row>
<row>
<column name="Notes">Burners all changed out, dirty cleaned and
ready for use.</column>
<column name="MaintLogID1">BRMR35023247</column>
</row>
<row>
<column name="Notes">High Temp. Alarms and Trips tested and working
correctly.
Lag compressor, cuts in and outs fine
Lead compressor, cuts in and outs fine.
</column>
<column name="MaintLogID1">BRMR35023263</column>
</row>
<row>
<column name="Notes">PM completed all in good order</column>
<column name="MaintLogID1">BRMR35023264</column>
</row>
<row>
<column name="Notes">pm complited all valves free moving </column>
<column name="MaintLogID1">BRMR35023265</column>
</row>
<row>
<column name="Notes">pm completed in good order</column>
<column name="MaintLogID1">BRMR35023266</column>
</row>
<row>
<column name="Notes">pm completed in good order</column>
<column name="MaintLogID1">BRMR35023267</column>
</row>
<row>
<column name="Notes">pm completed in good order</column>
<column name="MaintLogID1">BRMR35023268</column>
</row>
<row>
<column name="Notes">pm completed in order</column>
<column name="MaintLogID1">BRMR35023269</column>
</row>
<row>
<column name="Notes">Completed as per work instruction, Items
replenished as required</column>
<column name="MaintLogID1">BRMR35023274</column>
</row>
<row>
<column name="Notes">HP Trip, LP C/O, Low L.O. Trip, Hi Dish &
Oil Temp and chill p/p no flow trip tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35023275</column>
</row>
<row>
<column name="Notes">HP Trip, LP C/O, Low L.O. Trip, Hi Dish &
Oil Temp and chill p/p no flow trip tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35023276</column>
</row>
<row>
<column name="Notes">Greasing routine completed.</column>
<column name="MaintLogID1">BRMR35023277</column>
</row>
<row>
<column name="Notes">Completed as per workorder.
</column>
<column name="MaintLogID1">BRMR35023278</column>
</row>
<row>
<column name="Notes">Completed as per workorder.
</column>
<column name="MaintLogID1">BRMR35023279</column>
</row>
<row>
<column name="Notes">Completed as per workorder.</column>
<column name="MaintLogID1">BRMR35023280</column>
</row>
<row>
<column name="Notes">Completed as per workorder.</column>
<column name="MaintLogID1">BRMR35023281</column>
</row>
<row>
<column name="Notes">Completed as per workorder.</column>
<column name="MaintLogID1">BRMR35023282</column>
</row>
<row>
<column name="Notes">11th January 2007 No.2 Gyro Compass
7.0216.02
It was reported by the bridge that when the Autopilot was using No.2 Gyro
(prior to Suez canal transit), steering became
erratic therefore control was returned to No.1. A test was carried out
today under the above conditions and no problem was found.
It was, however noted that there was no position or speed indication on the
Compass Monitor Panel when No.2 Gyro was
selected.
No. 2 Gyro associated wiring was checked along with voltage levels. It was
noted that the levels were lower to the CMP for
No.2 Gyro than No.1. Further checks were made at No.2 Gyro and it was found
that cable cores that should have been
connected to TB4, terminals 7+8 were in fact connected to TB5, terminals
1+2 (repeater output) via a spliced-in extension cable.
As the repeater output data only gives course information, this would
explain why other information is missing. No reason could
be found why this modification was made, therefore the cores were
temporarily connected back to the correct position.
It appears that the CMP is working correctly and receiving the necessary
data stream.
</column>
<column name="MaintLogID1">BRMR35023283</column>
</row>
<row>
<column name="Notes">Alarms and trips tested as per work order, all
satisfactory except for cooling water low pressure alarm.
During testing this alarm starting going off repeatedly and then stayed up
continuously until disconnected. Water found on top
of switch diagphram, believe this to be the cause.
Unit reset to required alarm point and refitted until replacement arrives
to be fitted.
All other alarms and trips activated satisfactorily.</column>
<column name="MaintLogID1">BRMR35023284</column>
</row>
<row>
<column name="Notes">work completed by ships staff.
No further word from SHI, uneconomical to persue further, claim
closed.</column>
<column name="MaintLogID1">BRMR35023285</column>
</row>
<row>
<column name="Notes">received against P.O. 035/16/09624</column>
<column name="MaintLogID1">BRMR35023286</column>
</row>
<row>
<column name="Notes">Pipes replaced by ships staff.
No further word from SHI, uneconomical to persue further, claim
closed.</column>
<column name="MaintLogID1">BRMR35023287</column>
</row>
<row>
<column name="Notes">completed. Nozzles removed</column>
<column name="MaintLogID1">BRMR35023288</column>
</row>
<row>
<column name="Notes">No further word from SHI, uneconomical to
persue further, claim closed.
</column>
<column name="MaintLogID1">BRMR35023289</column>
</row>
<row>
<column name="Notes">work completed by ship's staff.
No further word from SHI, uneconomical to persue further, claim
closed.</column>
<column name="MaintLogID1">BRMR35023290</column>
</row>
<row>
<column name="Notes">
work completed by ship's staff.
Good condition
Light Scale noted on Fwd access ladder Top and Middle stringers have a
fine deposit of mud on horizontal surfaces.
This is generally less than 5mm deep and throughout spaces.
Bottom: localised deposits upto 2cm thick, generally clear of deposits.
0</column>
<column name="MaintLogID1">BRMR35023301</column>
</row>
<row>
<column name="Notes">Diesel alarms and trips all tested as per work
order. All operated at required setpoints satsfactorily.
Switchboard alarms and trips operated during ABB servicing of board 12/06
</column>
<column name="MaintLogID1">BRMR35023302</column>
</row>
<row>
<column name="Notes">Completed as per WO
</column>
<column name="MaintLogID1">BRMR35023303</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023304</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023305</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023306</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023307</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023308</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023309</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023310</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023311</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023312</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023313</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35023314</column>
</row>
<row>
<column name="Notes">Safety v/v removed for inspection after being
observed lifting.
Found to be in good order except being set a bit light.
V/V cleaned, lubed & rejointed.
Reset to 690kPa.
Refitted to HP heater and recommissioned.
No longer leaking.
</column>
<column name="MaintLogID1">BRMR35023315</column>
</row>
<row>
<column name="Notes">Tested and working satisfactorily</column>
<column name="MaintLogID1">BRMR35023316</column>
</row>
<row>
<column name="Notes">weekly pm routine done</column>
<column name="MaintLogID1">BRMR35023317</column>
</row>
<row>
<column name="Notes">weekly pm completed as per order.ok</column>
<column name="MaintLogID1">BRMR35023318</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
oreder.ok</column>
<column name="MaintLogID1">BRMR35023319</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023320</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023321</column>
</row>
<row>
<column name="Notes">weekly pm comleted as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023322</column>
</row>
<row>
<column name="Notes">weekly pm completed as as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023323</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
ordrer.ok</column>
<column name="MaintLogID1">BRMR35023324</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023325</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023326</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023327</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023328</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023329</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023330</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023331</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023332</column>
</row>
<row>
<column name="Notes">weekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023333</column>
</row>
<row>
<column name="Notes">wekly pm completed as per work
order.ok</column>
<column name="MaintLogID1">BRMR35023334</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Routes 3 + 4 tested.</column>
<column name="MaintLogID1">BRMR35023335</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023336</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023337</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023338</column>
</row>
<row>
<column name="Notes">Work as per schedule.
All working satisfactorily.</column>
<column name="MaintLogID1">BRMR35023339</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023340</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Tests being conducted and recorded in the GMDSS log book.</column>
<column name="MaintLogID1">BRMR35023341</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35023342</column>
</row>
<row>
<column name="Notes">Completed. Currently shut down for
maintenance</column>
<column name="MaintLogID1">BRMR35023343</column>
</row>
<row>
<column name="Notes">Completed. No.1 Priority</column>
<column name="MaintLogID1">BRMR35023344</column>
</row>
<row>
<column name="Notes">Completed, fluid levels checked and fine.
Starting and operation fine</column>
<column name="MaintLogID1">BRMR35023345</column>
</row>
<row>
<column name="Notes">Functions correctly as per PM. IAS alarm
working</column>
<column name="MaintLogID1">BRMR35023346</column>
</row>
<row>
<column name="Notes">Compressors changed over. Both running
fine</column>
<column name="MaintLogID1">BRMR35023347</column>
</row>
<row>
<column name="Notes">Compressors changed over. Both running
fine</column>
<column name="MaintLogID1">BRMR35023348</column>
</row>
<row>
<column name="Notes">Fluid levels checked and correct, engine run
on test with no problems noted</column>
<column name="MaintLogID1">BRMR35023349</column>
</row>
<row>
<column name="Notes">Fluid levels checked and correct, engine run
on test with no problems noted</column>
<column name="MaintLogID1">BRMR35023350</column>
</row>
<row>
<column name="Notes">Fluid levels checked and correct, engine run
on test with no problems noted</column>
<column name="MaintLogID1">BRMR35023351</column>
</row>
<row>
<column name="Notes">No.3 Compressor now priority 2.</column>
<column name="MaintLogID1">BRMR35023352</column>
</row>
<row>
<column name="Notes">Completed. No defects noted.</column>
<column name="MaintLogID1">BRMR35023353</column>
</row>
<row>
<column name="Notes">Completed. Air bottles at 195bar</column>
<column name="MaintLogID1">BRMR35023354</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023355</column>
</row>
<row>
<column name="Notes">Completed. Air bottles at 195bar</column>
<column name="MaintLogID1">BRMR35023356</column>
</row>
<row>
<column name="Notes">Completed, no defects noted</column>
<column name="MaintLogID1">BRMR35023357</column>
</row>
<row>
<column name="Notes">Completed, no defects noted</column>
<column name="MaintLogID1">BRMR35023358</column>
</row>
<row>
<column name="Notes">Completed, No.1 Air dryer now in use. Dewpoint
steady <-80 degC</column>
<column name="MaintLogID1">BRMR35023359</column>
</row>
<row>
<column name="Notes">Dryer shut down.</column>
<column name="MaintLogID1">BRMR35023360</column>
</row>
<row>
<column name="Notes">Completed, no defects noted</column>
<column name="MaintLogID1">BRMR35023361</column>
</row>
<row>
<column name="Notes">Completed, no defects noted</column>
<column name="MaintLogID1">BRMR35023362</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35023363</column>
</row>
<row>
<column name="Notes">Condition good, no deformation or damage
noted.
Condition Good
exceptions - TTop level under aft entrance 1 patch of scale/galvanic
deposits on longitudinal.
Some isolated spots of scale on edges of stringers &
Ligntning holes <0.1% Generally as new, Wastage <1% on bottom level
All pipework & fittings in good condition & secure
Generally Clean
Top and Middle stringers a thin layer of mud on horizontal surfaces, middle
leevl max 0.5cm on flat deck
Bottom some minor deposits <2 cm in small areas of some forward bays.
Generally Clean
0</column>
<column name="MaintLogID1">BRMR35023364</column>
</row>
<row>
<column name="Notes">Completed as per work order</column>
<column name="MaintLogID1">BRMR35023365</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023366</column>
</row>
<row>
<column name="Notes">Completed as per work instructuion</column>
<column name="MaintLogID1">BRMR35023367</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023368</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023369</column>
</row>
<row>
<column name="Notes">12TH January 2007 No.2 Cargo 6.6KV
Switchboard 6.7010.02
During the normal morning walkaround, it was noticed that there was a loud
vibration noise coming from Section 4 (reference
ABB drawing 302857001). Permits were raised and the switchboard isolated
and earthed at all points. Procedure was followed
concerning high voltage and all tests conducted before starting work.
Both front and back at Section 4 were removed and inspections carried out.
The following observations were made:-
À Panel wiring between adjacent sections was not protected from
abrasion by sharp edges (see photos).
Subsequently, rubber inserts were fitted and secured - work
complete.
À A side panel opposite the voltage transformers had not been
secured during assembly and 5 sets of nuts,
bolts and washers were missing (see photos). It was not
possible to fit the items without removing a substantial
number of panels etc. A rubber insert was fitted to prevent
vibration and a drydock spec will be raised. At the moment,
there is no danger of the panel working loose as it is
secured at other points.
</column>
<column name="MaintLogID1">BRMR35023370</column>
</row>
<row>
<column name="Notes">Generator run during testing of alarms and
trips 12-1-07</column>
<column name="MaintLogID1">BRMR35023376</column>
</row>
<row>
<column name="Notes">Generator test run on load, log as per ECR
hard copy, no problems/ defects noted.</column>
<column name="MaintLogID1">BRMR35023378</column>
</row>
<row>
<column name="Notes">Pump test run using local electric
start.</column>
<column name="MaintLogID1">BRMR35023380</column>
</row>
<row>
<column name="Notes">pm completed as per work order.All alarms and
trips tested.ok</column>
<column name="MaintLogID1">BRMR35023383</column>
</row>
<row>
<column name="Notes">All compressor Alarms and Trips tested and
operating correctly as per PM
Compressor Safety valve checked on bundenburg and lifting at 13.5bar.
Oil filter replaced with new, oil temperature control valve inspected and
cleaned.
Some small isolated patches of scale noted throughout tank, these numbering
less than a dozen. Generally found on leading edges and lightning holes.
Breakdown generally <0.1%. Beyond these exceptions coating pristine.
Bottom by tank suction - coating in good order. Some welding slag or
blasting grit rusting on coating
surface
It was noted that the top of the starter panel is not secured (only at
base). Chief engineer advised.</column>
<column name="MaintLogID1">BRMR35023392</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Meggered at 100M+.
It was noted that the top of the starter panel is not secured (only at
base). Chief engineer advised.</column>
<column name="MaintLogID1">BRMR35023393</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Meggered at 100M+.
Securing arrangement at top of starter panel not secure (one bolt very
loose, one bolt without nut).
Now OK.</column>
<column name="MaintLogID1">BRMR35023394</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Meggered at 100M+.
Securing arrangement at top of starter panel not secure (one bolt very
loose, one bolt without nut).
Now OK.</column>
<column name="MaintLogID1">BRMR35023395</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Meggered at 100M+.
Securing arrangement at top of starter panel not secure (one bolt very
loose, one bolt without nut).
Now OK.</column>
<column name="MaintLogID1">BRMR35023396</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Contacts inspected where possible. Very good condition.
Meggered at 100M+.</column>
<column name="MaintLogID1">BRMR35023397</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023398</column>
</row>
<row>
<column name="Notes">This PM is very ambiguous and is not
applicable to this ship based on the serial numbers presented.
However, limit switches operated by valves on the boiler have been checked
where practical, without
interrupting boiler operation.
Note: These valves are also inspected by the 2/E and stroked where
possible especially during normal
operation.</column>
<column name="MaintLogID1">BRMR35023399</column>
</row>
<row>
<column name="Notes">This PM is very ambiguous and is not
applicable to this ship based on the serial numbers presented.
However, limit switches operated by valves on the boiler have been checked
where practical, without
interrupting boiler operation.
Note: These valves are also inspected by the 2/E and stroked where
possible especially during normal
operation.</column>
<column name="MaintLogID1">BRMR35023400</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Contacts checked and cleaned where practical. All in good condition.
Meggered at 100M+.
</column>
<column name="MaintLogID1">BRMR35023401</column>
</row>
<row>
<column name="Notes">Work as per schedule.</column>
<column name="MaintLogID1">BRMR35023402</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35023403</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35023404</column>
</row>
<row>
<column name="Notes">All checked as per PM and found to be in good
condition ready for immediate use.</column>
<column name="MaintLogID1">BRMR35023405</column>
</row>
<row>
<column name="Notes">All life buoys checked and found to be in good
condition ready for immediate use.</column>
<column name="MaintLogID1">BRMR35023406</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35023407</column>
</row>
<row>
<column name="Notes">Work as per schedule.
Satisfactory operation and in good condition. Tested by 3rd
Officer.</column>
<column name="MaintLogID1">BRMR35023408</column>
</row>
<row>
<column name="Notes">Condition good. No damage or deformation
noted. Condition good, some light breakdown on leading edges of stringers
and lightning holes. This isolated and largely on platform 1 level up from
bottom. Condition Good, generally as new <1% wastage on bottom level.
Some minor scale on one or two anodes at top stringer and some scale on rod
at clamps on top level, particularly forward.
Condition Good, all fittings and pipework secure. Some scale on
ladders and guard rails, particularly on upper levels. Thin layer of
Mud on top and middle stringers concentrated on horizontal surfaces, this
upto 1cm thick in places on 1st level from bottom.
Bottom generally clean with with deposit build up of upo 5cm in places,
particularly forward.. </column>
<column name="MaintLogID1">BRMR35023409</column>
</row>
<row>
<column name="Notes">1 patch possible damage noted BWO frame 115 by
catwalk at bottom. Galvanic deposits measuring approx 20cm x 10 cm. This
possibly caused by minor indentation. Condition Good, Minor breakdown
in isolated places, these less than 1 cm in diameter Condition Good,
generally as new. Bottom level < 1% wastage
Condition good.
All fixtures & pipework in place and secure
Light Corrosion present on ladders & guard rails on upper levels.
Top and Middle stringers a thin layer of mud on horizontal
surfaces,
Bottom generally clean, light deposits upto 2cm thick in places.
</column>
<column name="MaintLogID1">BRMR35023410</column>
</row>
<row>
<column name="Notes">pm completd as per work order.ok</column>
<column name="MaintLogID1">BRMR35023411</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023412</column>
</row>
<row>
<column name="Notes">pm completed as per work order.0k</column>
<column name="MaintLogID1">BRMR35023413</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023414</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023415</column>
</row>
<row>
<column name="Notes">Work completed and recorded by 3/O.</column>
<column name="MaintLogID1">BRMR35023416</column>
</row>
<row>
<column name="Notes">Pump inspected OK, all holding down bolts
tight, shaft coupling rubber in good condition. Mechanical seal not
leaking.
Pump run, no abnormal noise/vibration observed. Pump suction- 0bar,
discharge- 0.4 bar.</column>
<column name="MaintLogID1">BRMR35023417</column>
</row>
<row>
<column name="Notes">Pump inspected satisfatorily, all holding down
bolts secure, shaft coupling bolts tight. No leakage observed from
mechanical
seal. Pump not run, turned easily by hand.</column>
<column name="MaintLogID1">BRMR35023418</column>
</row>
<row>
<column name="Notes">All sets checked satisfactorily. Tank entry
standby sets are a bit battered but OK. </column>
<column name="MaintLogID1">BRMR35023419</column>
</row>
<row>
<column name="Notes">Condition good with no damage or deformation
noted
No cold spots noted. Condition good
Some rust/coating detachment at manholes
Otherwise coating almost pristine with only a very isolated number of rust
spots noted @ 1cm in diameter
Condition Good
Generally as new, bottom level <1% wastage
Condition good, all fittings & pipelines secure Light deposits
on horizontal surfaces on upper level, Deposits of upto 1cm present on
middle levels.
Bottom level generally clean with isolated patches of deposits up to 1cm
deep </column>
<column name="MaintLogID1">BRMR35023420</column>
</row>
<row>
<column name="Notes">Tested and working satisfactorily.
Calibration gas onboard is 0.08% (0.35mg/l) BrAC, and not the standard
0.05% (0.22 mg/l) BrAC.
Unit is correctly calibrated against this gas standard.
New calibration gas (0.22mg/l) ordered on 17th January 2007 on
MER/07/00030)</column>
<column name="MaintLogID1">BRMR35023421</column>
</row>
<row>
<column name="Notes">Button on C deck activated. All OK</column>
<column name="MaintLogID1">BRMR35023422</column>
</row>
<row>
<column name="Notes">Batteries replaced.
26.21v 24.50v
No.2 DGPS loses posn at midnight but otherwise operation good would suggest
software problem internally
aerial in good condition.</column>
<column name="MaintLogID1">BRMR35023563</column>
</row>
<row>
<column name="Notes">Equipment appears to be operating
satisfactorily.
No defects reported at present time by navigational dept.</column>
<column name="MaintLogID1">BRMR35023564</column>
</row>
<row>
<column name="Notes">No.1 Burner C/O and cleaned.</column>
<column name="MaintLogID1">BRMR35023565</column>
</row>
<row>
<column name="Notes">Watchcall and OMBO tested and working
satisfactorily</column>
<column name="MaintLogID1">BRMR35023593</column>
</row>
<row>
<column name="Notes">Filters cleaned on watches every 4 hours
whilst at MCR. Nothing out of the ordinary
27/01/07</column>
<column name="MaintLogID1">BRMR35023594</column>
</row>
<row>
<column name="Notes">All alarms tested as part of weekly routines.
All OK
27/01/07</column>
<column name="MaintLogID1">BRMR35023595</column>
</row>
<row>
<column name="Notes">All fire pneumatic fire flaps tested and found
to be in good order.
Supply fan flaps also tested and operation ok.
27/01/07</column>
<column name="MaintLogID1">BRMR35023596</column>
</row>
<row>
<column name="Notes">No problems.
27/01/07</column>
<column name="MaintLogID1">BRMR35023597</column>
</row>
<row>
<column name="Notes">Alarm activated on activation of probe.
All Ok
27/01/07</column>
<column name="MaintLogID1">BRMR35023598</column>
</row>
<row>
<column name="Notes">All non running and spare motors/pumps rotated
fully and stopped in different position.
All ok.
27/01/07</column>
<column name="MaintLogID1">BRMR35023599</column>
</row>
<row>
<column name="Notes">Photo-resistor removed and cleaned with a damp
cloth.
Air inlet ports checked - all ok.
27/01/07</column>
<column name="MaintLogID1">BRMR35023600</column>
</row>
<row>
<column name="Notes">Hoses tested on weekly rotation.
Hoases tested were found to be ok with no leaks at full pressure.
27/01/07</column>
<column name="MaintLogID1">BRMR35023601</column>
</row>
<row>
<column name="Notes">Both units checked with soap and
meter</column>
<column name="MaintLogID1">BRMR35023602</column>
</row>
<row>
<column name="Notes">Both units and system checked with soap and
meter</column>
<column name="MaintLogID1">BRMR35023603</column>
</row>
<row>
<column name="Notes">Inspected in operation</column>
<column name="MaintLogID1">BRMR35023604</column>
</row>
<row>
<column name="Notes">Ran on test through condenser</column>
<column name="MaintLogID1">BRMR35023605</column>
</row>
<row>
<column name="Notes">Both units checked on run up</column>
<column name="MaintLogID1">BRMR35023606</column>
</row>
<row>
<column name="Notes">deadman and patrolman tested</column>
<column name="MaintLogID1">BRMR35023607</column>
</row>
<row>
<column name="Notes">As per routines sheet</column>
<column name="MaintLogID1">BRMR35023608</column>
</row>
<row>
<column name="Notes">As per routines sheet</column>
<column name="MaintLogID1">BRMR35023609</column>
</row>
<row>
<column name="Notes">As per routines sheet</column>
<column name="MaintLogID1">BRMR35023610</column>
</row>
<row>
<column name="Notes">As per routines sheet</column>
<column name="MaintLogID1">BRMR35023611</column>
</row>
<row>
<column name="Notes">As per routines sheet</column>
<column name="MaintLogID1">BRMR35023612</column>
</row>
<row>
<column name="Notes">Lifeboat checked as per pm.
27/01/07</column>
<column name="MaintLogID1">BRMR35023613</column>
</row>
<row>
<column name="Notes">Lifeboat checked and run as per pm.
All ok no problems found
27/01/07</column>
<column name="MaintLogID1">BRMR35023614</column>
</row>
<row>
<column name="Notes">Lifeboat checked and run as per pm.
No problems found
27/01/07</column>
<column name="MaintLogID1">BRMR35023615</column>
</row>
<row>
<column name="Notes">Rescue boat checked and run as per weekly pm.
27/01/07</column>
<column name="MaintLogID1">BRMR35023616</column>
</row>
<row>
<column name="Notes">Lifeboat checked as per pm
27/01/07</column>
<column name="MaintLogID1">BRMR35023617</column>
</row>
<row>
<column name="Notes">pm comleted as per work order.ok</column>
<column name="MaintLogID1">BRMR35023618</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023619</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023620</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023621</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023622</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023623</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023624</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023625</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023626</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023627</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023628</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023629</column>
</row>
<row>
<column name="Notes">pm completd as per work order.ok</column>
<column name="MaintLogID1">BRMR35023630</column>
</row>
<row>
<column name="Notes">pm completd as per work order.ok</column>
<column name="MaintLogID1">BRMR35023631</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023632</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023633</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023634</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023635</column>
</row>
<row>
<column name="Notes">Completed. No.3 3rd priority</column>
<column name="MaintLogID1">BRMR35023636</column>
</row>
<row>
<column name="Notes">Completed. No.1 priority 2.</column>
<column name="MaintLogID1">BRMR35023637</column>
</row>
<row>
<column name="Notes">Completed. No.2 Lag.</column>
<column name="MaintLogID1">BRMR35023638</column>
</row>
<row>
<column name="Notes">Completed. No.1 Lead</column>
<column name="MaintLogID1">BRMR35023639</column>
</row>
<row>
<column name="Notes">Completed. No.1 Priority</column>
<column name="MaintLogID1">BRMR35023640</column>
</row>
<row>
<column name="Notes">Dryers changed over. No.1 In use.</column>
<column name="MaintLogID1">BRMR35023641</column>
</row>
<row>
<column name="Notes">Dryers Changed over, No.2 shut down</column>
<column name="MaintLogID1">BRMR35023642</column>
</row>
<row>
<column name="Notes">Routes 8 and 17 fully tested
satisfactorily.</column>
<column name="MaintLogID1">BRMR35023643</column>
</row>
<row>
<column name="Notes">Not Legitimate claim. Not in original
spec.</column>
<column name="MaintLogID1">BRMR35023644</column>
</row>
<row>
<column name="Notes">claim closed.</column>
<column name="MaintLogID1">BRMR35023645</column>
</row>
<row>
<column name="Notes">Elevator alarm tested and audible in
wheelhouse and engineroom.
Emergency phones tested ok.
Sunday 28th Elevator isolated on Bp instructions .
Power turned off at control panel</column>
<column name="MaintLogID1">BRMR35023646</column>
</row>
<row>
<column name="Notes">External lighting satisfactory.
No known or reported defects and insulation above 2 Meg ohms</column>
<column name="MaintLogID1">BRMR35023647</column>
</row>
<row>
<column name="Notes">VHF DSC tests ok.
Unable to test MF/HF due Antenna damage awaiting spare antenna</column>
<column name="MaintLogID1">BRMR35023648</column>
</row>
<row>
<column name="Notes">Rudder angle indicator checked and found
satisfactory.
Rudder angle accurate when compared to SG room.
Linkages on feedback unit are secure</column>
<column name="MaintLogID1">BRMR35023649</column>
</row>
<row>
<column name="Notes">claim closed resolved on board</column>
<column name="MaintLogID1">BRMR35023650</column>
</row>
<row>
<column name="Notes">2 piece Hospital Alarms tested ok.
Alarm operates satisfactorily within the CCR and registers on alarm printer
in CCR.</column>
<column name="MaintLogID1">BRMR35023651</column>
</row>
<row>
<column name="Notes">3 pce Refrigeration locked in alarms tested
satisfactorily.
Alarm registers audibly within the CCR and registers on alarm printer
satisfactorily.
All push buttons box units lamped up as required and all lamps illuminated.
</column>
<column name="MaintLogID1">BRMR35023652</column>
</row>
<row>
<column name="Notes">Load test carried out (175kw) for 30 mins
Entek readings taken at this time
All pressures and temps within normal ange </column>
<column name="MaintLogID1">BRMR35023653</column>
</row>
<row>
<column name="Notes">Pump ran on test in parallel with duty feed
pump</column>
<column name="MaintLogID1">BRMR35023654</column>
</row>
<row>
<column name="Notes">Carried out as part of monthly load
test.</column>
<column name="MaintLogID1">BRMR35023655</column>
</row>
<row>
<column name="Notes">Manual received onboard on 11th November 2006,
marked HSSE-ER-ER-GLOBALCD-02, and stowed
adjacent to SOPEP</column>
<column name="MaintLogID1">BRMR35023656</column>
</row>
<row>
<column name="Notes">Completed asm part of monthly load
test.</column>
<column name="MaintLogID1">BRMR35023657</column>
</row>
<row>
<column name="Notes">Priming pump rotated by hand, water tank
topped up</column>
<column name="MaintLogID1">BRMR35023658</column>
</row>
<row>
<column name="Notes">Priming pump rotated by hand, Water tank
topped up.</column>
<column name="MaintLogID1">BRMR35023659</column>
</row>
<row>
<column name="Notes">Primig pump rotated by hand, water tank topped
up</column>
<column name="MaintLogID1">BRMR35023660</column>
</row>
<row>
<column name="Notes">Priming pump rotated, water tank topped
up</column>
<column name="MaintLogID1">BRMR35023661</column>
</row>
<row>
<column name="Notes">Priming pump rotated by hand, water tank
topped up</column>
<column name="MaintLogID1">BRMR35023662</column>
</row>
<row>
<column name="Notes">Manual shipside v/v's worked through
range</column>
<column name="MaintLogID1">BRMR35023663</column>
</row>
<row>
<column name="Notes">All B.A sets checked. 1 neck strap found
almost snapped. Replaced with spare
Bottles 21 and 29 found to be below 280, bottles re-charged</column>
<column name="MaintLogID1">BRMR35023664</column>
</row>
<row>
<column name="Notes">Pumped failed to prime. On inspection priming
pump found not to be turning. Priming pump isolated and turned manually
Pump re-tried and operated satisfactory.
Entek readings taken at this time. </column>
<column name="MaintLogID1">BRMR35023665</column>
</row>
<row>
<column name="Notes">Engine Control Room Telephone high pitched
noise on the line making audio very faint.
Find by caressing the handset chord noise comes and goes.
Replaced handset chord and "phone" is completely dead with no
audio or dial tone.
Removed portable telephone unit from No.2 switchboard and wire into place
and find audio poor with
dial tone but unable to dial out.
Replaced telephone back into No.2 switchboard portable box
Both phones have defective keypad PCBs.
Removed No.1 switchboard portable telephone and wire into ECR console and
fully operational
with good audio capability, left as is to make ECR console operational.
The ECR unit has also shaken itself to pieces, therefore to make
operational what started out as
1 fault now have 2 phones to repair.
The dial buttons ordered as when on trader albeit they are just plastic
spacers which are easily lost
and can render a phone keypad defunct,but fabricated ones just do not
operate quite as slick.</column>
<column name="MaintLogID1">BRMR35023666</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023667</column>
</row>
<row>
<column name="Notes">High Oil content alarm activated. operation OK
27/01/07</column>
<column name="MaintLogID1">BRMR35023668</column>
</row>
<row>
<column name="Notes">ompleted as per work instruction</column>
<column name="MaintLogID1">BRMR35023669</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023670</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023671</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023672</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023673</column>
</row>
<row>
<column name="Notes">323 326 293 295
329 330 296 298 304 290
303 286 112 99.36 111.2 100.39 241 241
99.5 99.39 Ref Nos 3 &
4 UPS supplies. To put these UPS on battery ONLY the main
breakers require to be isolated, the emergency supply is for BYPASS use
only</column>
<column name="MaintLogID1">BRMR35023674</column>
</row>
<row>
<column name="Notes">During the course of work checked telephones
as follows:-
FCC - Wheelhouse
Cargo Switchboards Nos 1 & 2 - Whelhouse
ECR -Wheelhouse
CCR - Wheelhouse
Wheelhouse - CCR
satisfactory operation.</column>
<column name="MaintLogID1">BRMR35023675</column>
</row>
<row>
<column name="Notes">Equipment is operating satisfactorily.
There are no reported defects with this equipment at this time.</column>
<column name="MaintLogID1">BRMR35023676</column>
</row>
<row>
<column name="Notes">Engine Control Room Telephone high pitched
noise on the line making audio very faint.
Find by caressing the handset chord noise comes and goes.
Replaced handset chord and "phone" is completely dead with no
audio or dial tone.
Removed portable telephone unit from No.2 switchboard and wire into place
and find audio poor with
dial tone but unable to dial out.
Replaced telephone back into No.2 switchboard portable box
Both phones have defective keypad PCBs.
Removed No.1 switchboard portable telephone and wire into ECR console and
fully operational
with good audio capability, left as is to make ECR console operational.
The ECR unit has also shaken itself to pieces, therefore to make
operational what started out as
1 fault now have 2 phones to repair.
Amos Numbers:
7.1941.11.090 Flush Type Telephone SAB-401C Require 2pce
7.1941.11.092 PCB Require 4 pce
7.1941.11.094 Handset chords Require 3 pce
7.1941.11.097 Dial Button Require 30 pce
The dial buttons ordered as when on trader albeit they are just plastic
spacers which are easily lost
and can render a phone keypad defunct,but fabricated ones just do not
operate quite as slick.</column>
<column name="MaintLogID1">BRMR35023677</column>
</row>
<row>
<column name="Notes">No reported defects in any laundry.
All tumbledryers cleaned of dust/debri, find in all cases when debri tray
at bottom of machines removed
the microswitch which difficult to see is covered in fluff debri, brushed
clean on every machine.
door interlocks operational on all machines.
earth leakage trip on all machines operational.
</column>
<column name="MaintLogID1">BRMR35023678</column>
</row>
<row>
<column name="Notes">batteries in a clean secure condition.
Terminals secure and vaselined.
UPS 5 UPS 6
Batt Start Dis End Dis Start Dis End Dis
1 12.44 12.43 12.62 12.55
2 12.46 12.44 12.63 12.56
3 12.47 12.43 12.63 12.56
4 12.46 12.42 12.61 12.52
5 12.41 12.39 12.6 12.52
6 12.42 12.43 12.48 12.43
7 12.44 12.41 12.62 12.54
8 12.43 12.39 12.62 12.57
</column>
<column name="MaintLogID1">BRMR35023686</column>
</row>
<row>
<column name="Notes">Completed. No significant build up of deposits
noted.</column>
<column name="MaintLogID1">BRMR35023687</column>
</row>
<row>
<column name="Notes">Completed. No significant build up of dirt
noted</column>
<column name="MaintLogID1">BRMR35023688</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023689</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023690</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023691</column>
</row>
<row>
<column name="Notes">Main Mast Fittings checked 17.01.2007 and all
found secure and no defects observed.
At Nav Light outgoing terminal wiring from Nav light control panel, With
fuses removed, the various
nav lights meggared on outgoing cables from K.3X1 terminals 6 thru to 29,
all circuits >20 Meg Ohms.
No defects known or reported at this time.
</column>
<column name="MaintLogID1">BRMR35023692</column>
</row>
<row>
<column name="Notes">Filters and frames inspected no cleaning
needed</column>
<column name="MaintLogID1">BRMR35023693</column>
</row>
<row>
<column name="Notes">Filters and frames inspected no cleaning
needed</column>
<column name="MaintLogID1">BRMR35023694</column>
</row>
<row>
<column name="Notes">Filters and frames inspected no cleaning
needed</column>
<column name="MaintLogID1">BRMR35023695</column>
</row>
<row>
<column name="Notes">Filters and frames inspected no cleaning
needed</column>
<column name="MaintLogID1">BRMR35023696</column>
</row>
<row>
<column name="Notes">ran on test satisfactory</column>
<column name="MaintLogID1">BRMR35023697</column>
</row>
<row>
<column name="Notes">Cleaned no defects observed</column>
<column name="MaintLogID1">BRMR35023698</column>
</row>
<row>
<column name="Notes">inspected no defects observed</column>
<column name="MaintLogID1">BRMR35023699</column>
</row>
<row>
<column name="Notes">greasing carried out. all linkages and joints
checked</column>
<column name="MaintLogID1">BRMR35023700</column>
</row>
<row>
<column name="Notes">Cooler backflushed for 20 minutes, no 2
returned to service</column>
<column name="MaintLogID1">BRMR35023701</column>
</row>
<row>
<column name="Notes">Cooler backflushed for 20 minutes, no 2
returned to service</column>
<column name="MaintLogID1">BRMR35023702</column>
</row>
<row>
<column name="Notes">1) Navigation portside console SM10-2 monitor
working satisfactory.
Navigation starboard side console monitor missing, original defective.
Had hoped to receive new LCD monitor but failed to arrive, therefore tech
prepared computer for arrival of
new LCD screen.
See photocopied sheets attached to ecdis manual.
OS4
SVC-OS4 fitted computer with replacement PC Main Board (SOYO) and a new
hard disk
Seagate disk Barracuda for: MP510,MP 530,MC71,COS100,COS200 Type:
7200.7,286692-001
and software reinstalled.
No wiring to above spec avail, use what 10mm OD armoured cable, that ship
has and rewire from probe to forward B3B junction box, securing throughout
internally in alternator casing.
Generator run up and tested satisfactorily.
W0P701194 059</column>
<column name="MaintLogID1">BRMR35023778</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023779</column>
</row>
<row>
<column name="Notes">Completed as per work Instruction</column>
<column name="MaintLogID1">BRMR35023780</column>
</row>
<row>
<column name="Notes">Completed as per work Instruction</column>
<column name="MaintLogID1">BRMR35023781</column>
</row>
<row>
<column name="Notes">Completed as per work Instruction</column>
<column name="MaintLogID1">BRMR35023782</column>
</row>
<row>
<column name="Notes">Completed as per work Instruction</column>
<column name="MaintLogID1">BRMR35023783</column>
</row>
<row>
<column name="Notes">Completed as per work Instruction</column>
<column name="MaintLogID1">BRMR35023784</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023785</column>
</row>
<row>
<column name="Notes">High Level alarm activation ok.
05/02/07</column>
<column name="MaintLogID1">BRMR35023786</column>
</row>
<row>
<column name="Notes">High Level alarm activation ok
05/02/07</column>
<column name="MaintLogID1">BRMR35023787</column>
</row>
<row>
<column name="Notes">High Level alarm activation ok
05/02/07</column>
<column name="MaintLogID1">BRMR35023788</column>
</row>
<row>
<column name="Notes">High Level alarm activation ok
05/02/07</column>
<column name="MaintLogID1">BRMR35023789</column>
</row>
<row>
<column name="Notes">High level alarm activation ok
05/02/07</column>
<column name="MaintLogID1">BRMR35023790</column>
</row>
<row>
<column name="Notes">High Level alarm activation ok
05/02/07</column>
<column name="MaintLogID1">BRMR35023791</column>
</row>
<row>
<column name="Notes">High Oil content alarm activated all ok
03/02/07</column>
<column name="MaintLogID1">BRMR35023792</column>
</row>
<row>
<column name="Notes">Hoses tested on rotation all ok no defects
reported.
03/02/07</column>
<column name="MaintLogID1">BRMR35023793</column>
</row>
<row>
<column name="Notes">Lifeboat checked as part of weekly routines
all ok.
Engine started 3 times on each battary in conjunction with ETO's test
of battaries.
03/02/07</column>
<column name="MaintLogID1">BRMR35023794</column>
</row>
<row>
<column name="Notes">Lifeboat checks done as part of weekly
routines.
03/02/07</column>
<column name="MaintLogID1">BRMR35023795</column>
</row>
<row>
<column name="Notes">Rescue boat checked as part of weekly
routines.
03/02/07</column>
<column name="MaintLogID1">BRMR35023796</column>
</row>
<row>
<column name="Notes">2 bags dosed - all ok
03/02/07</column>
<column name="MaintLogID1">BRMR35023797</column>
</row>
<row>
<column name="Notes">Compressors changed over duties on the IAS
03/02/07</column>
<column name="MaintLogID1">BRMR35023798</column>
</row>
<row>
<column name="Notes">Compressors changed over duties on teh IAS
03/02/07</column>
<column name="MaintLogID1">BRMR35023799</column>
</row>
<row>
<column name="Notes">High oil content alarm activation - all ok
03/02/07</column>
<column name="MaintLogID1">BRMR35023800</column>
</row>
<row>
<column name="Notes">Photo resistor removed and cleaned using domp
cloth.
Resistor found to be clean
03/02/07</column>
<column name="MaintLogID1">BRMR35023801</column>
</row>
<row>
<column name="Notes">Lifeboat checked as part of weekly routines.
All ok no problems found.
03/02/07</column>
<column name="MaintLogID1">BRMR35023802</column>
</row>
<row>
<column name="Notes">Lifeboat checked as part of weekly routines.
03/02/07</column>
<column name="MaintLogID1">BRMR35023803</column>
</row>
<row>
<column name="Notes">Dynamo V-belt checked for trension and wear
found to be in good condition.
Sprinlkler pump and valve found to be in good condition.
03/02/07</column>
<column name="MaintLogID1">BRMR35023804</column>
</row>
<row>
<column name="Notes">Dynamo V-belt checked for tension and wear and
found to be in good condition
Sprinkler pump and valve checked and all ok
03/02/07</column>
<column name="MaintLogID1">BRMR35023805</column>
</row>
<row>
<column name="Notes">Oil probes checked during ormal operationof
seperator both found to be in good working order.
02/02/07</column>
<column name="MaintLogID1">BRMR35023806</column>
</row>
<row>
<column name="Notes">All pumps in pm and the 11 spare motors on 4th
deck rotated by hand and left in different position.
All breakersn on conected pumps were isolated beroe turning.
04/02/07</column>
<column name="MaintLogID1">BRMR35023807</column>
</row>
<row>
<column name="Notes">All dampers listed in pm were activated and no
problems were found.
04/02/07</column>
<column name="MaintLogID1">BRMR35023808</column>
</row>
<row>
<column name="Notes">all system and individual components checked
no defects observed</column>
<column name="MaintLogID1">BRMR35023809</column>
</row>
<row>
<column name="Notes">Greased and all fittings inspected</column>
<column name="MaintLogID1">BRMR35023810</column>
</row>
<row>
<column name="Notes">Starter inspected and find in a clean operable
condition with no signs of any overheating of any
components/cabling.
Terminals secure throughout starter and at the rear on the aux contact
strip wiring and motor terminal
wiring, motor terminal casings dust free.
Main contactor SC12N (400) contacts fixed and moving removed and dressed
up.Arc shutes are good.
Fixed contacts are secure
Contactor SC6N (125) contacts/arc shutes inspected and find in good
condition.
Fixed contacts are secure
Overload is set at 80A and consistent with red spot marking.
Fuses are correct size and rating with fuse holders in good condition.
Space heater impedance is 338 ohm and 220V feed satisfactory.
Control Panel lamps lamped up as required and operational.
Motor terminal box cover removed and retaining bolts all greased.
Motor terminals are secure and no sign of any overheating and insulation
material is in good condition.
Insulation starter to motor in excess of 100 meg ohms for high & Low
speeds.
Motor earth cabling attached and in good condition and connected to ground.
Space heater box cover removed and retaining bolts greased.
Space heater terminal block connections tightened.</column>
<column name="MaintLogID1">BRMR35023811</column>
</row>
<row>
<column name="Notes">324 326 0 293 295 0
329 330 0 296 298 0 304 290
303 286 112 99.4 111.5 100.4 241 241
99.5 0 0 99.38 0 0 Ref Nos 3 &
4 UPS, to put UPS on battery only the main switchboard breakers require
isolating. The emg supply is the bypass supply only.
Saturday 03 Feb 2007</column>
<column name="MaintLogID1">BRMR35023812</column>
</row>
<row>
<column name="Notes">Original Thyristor cooling fans Removed from
service as per W.O
Original type was:-
NMB Model 4710PS-12T-B30 115Vac 1 Phase 50/60hz 14/11W Impedance
protected.
Fans still working ok.
03/02/07</column>
<column name="MaintLogID1">BRMR35023814</column>
</row>
<row>
<column name="Notes">Battery charger isolated 030800hrs
Voltage at start of disch test: 24.41V
Voltage at end of discharge: 24.33V
Discharge Current: steady at 5.3A
Battery charger reconnected 031800hrs
Batteries fully recharged.
These details also placed in GMDSS LOGBOOK for this test.
24.41v 24.33v
New Thyristor cooling fans installed 05Feb2007 Aft Unit and 06-Feb-2007
Forward Unit
Sunon SP101AT 115Vac 50/60hz 0.21/0.19A Impedance protected
RS 5440318 SP101AT/1122HBL.GN
The new fans required mounting holes further drilled out and 5mm threads
tapping in fan casings so
that they could be satisfactorily mounted.
Wiring cable tied to fan casings and wired in parallel, new ring crimps
attached to enable this.
Aft Unit switched on and satisfactory operation.
</column>
<column name="MaintLogID1">BRMR35023824</column>
</row>
<row>
<column name="Notes">TRON 40S EPIRB
Serial No. 131AH21518
Battery Expiry Date: Jan 2012
Hydrostatic Release Expiry: Jan 2009
This unit recently exchanged in January, the old unit sent back for service
less batteries.
Unit tested satisfactory and in good condition.
Test details in GMDSS Log Book</column>
<column name="MaintLogID1">BRMR35023825</column>
</row>
<row>
<column name="Notes">Sart Units Fitted on Bridge.
Portside Tron Sart
Ser.No. 1LB30543
Battery Expiry Date: Dec 2009
Forward Battery
13.0v Off charge, drops to 11.0V on engine fire up, 14.0V alternator
charge with engine running.
Engine given 2 starts satisfactorily from this battery.
Aft Battery
13.1V Off Charge, drops to 11.0V region on engine fire up, 14.0V alternator
charge with engine running.
Engine given 2 starts satisfactorily from this battery.</column>
<column name="MaintLogID1">BRMR35023838</column>
</row>
<row>
<column name="Notes">Filters removed and cleaned</column>
<column name="MaintLogID1">BRMR35023839</column>
</row>
<row>
<column name="Notes">Inspected but not cleaned as this unit not in
use</column>
<column name="MaintLogID1">BRMR35023840</column>
</row>
<row>
<column name="Notes">Equipment operatiion satisfactory.
1 Alarm S required resetting but unit reset and run ok
Visually in good condition.
05/02/07</column>
<column name="MaintLogID1">BRMR35023842</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023843</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023844</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023845</column>
</row>
<row>
<column name="Notes">pm complete as per work order.ok</column>
<column name="MaintLogID1">BRMR35023846</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023847</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 120A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC7N(150) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 437 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminals tightened as found loose.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35023848</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 52A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC3N(65) contacts fixed/moving and arc shutes all in
good condition..
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 1600 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminals secure.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35023849</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout & at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 4.9A which not consistenent with the red spot marking,
and indicator on front panel
mounted meter,adjusted to 4.5A to make consistent..
The main contactor SC-5-1(18) contacts fixed/moving and arc shutes all in
good condition.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure,
no sign of any overheating..
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35023850</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 19A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC1N(26) contacts fixed/moving and arc shutes all in
good condition.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 1600 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminals secure.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35023851</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory.
Visually unit is in good clean operating condition.
There are no known or reported deficiencies at this time.
Unit opened up and visually inspected internally and find clean with no
dust buildup and no signs of
any component or wiring overheating.
Unit output to dedicated printer checked and satisfactory
printing.</column>
<column name="MaintLogID1">BRMR35023852</column>
</row>
<row>
<column name="Notes">Whistle inspected and find in a satisfactory
condition.
Unit is operable as witnessed on practice piracy attack drill .</column>
<column name="MaintLogID1">BRMR35023853</column>
</row>
<row>
<column name="Notes">Equipment is working satisfactorily as
evidenced by OOW sounding it for noon.
Unit is secure and in good condition up foremast.</column>
<column name="MaintLogID1">BRMR35023854</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory.
No known or reported defects with this aft unit, at this time.
Antenna is securely mounted.</column>
<column name="MaintLogID1">BRMR35023855</column>
</row>
<row>
<column name="Notes">No.1 DGPS operation satisfactory and aerial in
good condition.
AIS GPS working satisfactory and aerial in good condition
No.2 DGPS loses posn at midnight but otherwise operation good would suggest
software problem internally
aerial in good condition.</column>
<column name="MaintLogID1">BRMR35023856</column>
</row>
<row>
<column name="Notes">Emergency Diesel Starting batteries inspected.
Battery tops are clean, terminals secure and vaselined.
On Float Charge
Battery No.1: 12.56V
Battery No.2: 12.62V
Battery No.3: 12.59V
Battery No.4: 12.59V
Air cooler cleaned through, light fouling only. Some Corrosion found inside
air outlet piping.
Hours: 10800
7/02/2007</column>
<column name="MaintLogID1">BRMR35023871</column>
</row>
<row>
<column name="Notes">Completed as per PM</column>
<column name="MaintLogID1">BRMR35023872</column>
</row>
<row>
<column name="Notes">Completed in parallel with unscheduled
maintenance for Cleaning of L.O. and Air coolers.
10/02/07</column>
<column name="MaintLogID1">BRMR35023879</column>
</row>
<row>
<column name="Notes">Starter opened and inspected.
Cleaned dust deposits from terminal block connections, various components
and motor output terminal
blocks as quite heavily deposited.
Wiring checked and found secure with no sign of overheating.
Contactor SC7N contacts inspected and find in a contaminated/dirty/scored
condition
along witharc shutes.
Fixed/Moving contacts Replaced.Arc shute cleaned as best as possible but
requires replacement.
No spares
Overload at 80A and consistent with red spot marking.
Fuses and fuseholders in good condition and fitted with correct rated
fuses.
Impedance of motor space heater 17 ohm and 220v feed satisfactory.
Insulation starter to motor in excess of 100 meg ohms.
Indicator alarm panel bulbs checked and all operational.
Motor terminal box cover removed, retaining bolts greased.
Motor wiring secure with no signs of overheating and insulation of wiring
good.
thermistor and space heater terminals secure.
Motor insulation to earth in >100 Meg ohms</column>
<column name="MaintLogID1">BRMR35023880</column>
</row>
<row>
<column name="Notes">All strum boxes opened and checked and found
to be free.
All valve worked and good movement of travel.
11/02/07</column>
<column name="MaintLogID1">BRMR35023881</column>
</row>
<row>
<column name="Notes">Electrical Deck Insulation Readings
CCT
1 42 Megs
2 20 Megs
3 6 Megs
4 2 Megs
5 100 Megs
6 100 Megs
7 100 Megs
8 2 Megs
9 100 Megs
10 100 Megs
11 100 Megs
12 100 Megs
13 100 Megs
14 40 Megs
15 100 Megs
16 100 Megs
17 100 Megs
18 100 Megs
19 100 Megs
20 100 Megs
21 100 Megs
22 100 Megs
23 100 Megs
24 28 Megs
25 100 Megs
26 100 Megs
27 100 Megs
28 100 Megs
29 100 Megs
30 100 Megs
31 100 Megs
32 100 Megs
33 100 Megs
34 41 Megs
35 25 Megs
36 100 Megs
37 100 Megs
38 100 Megs
39 100 Megs
40 100 Megs
41 100 Megs
42 100 Megs
43 40 Megs
44 100 Megs
</column>
<column name="MaintLogID1">BRMR35023882</column>
</row>
<row>
<column name="Notes">Equipment is operational.
There are no known or reported defects with this equipment.
Scanner mounting bolts all present and secure.</column>
<column name="MaintLogID1">BRMR35023883</column>
</row>
<row>
<column name="Notes">Equipment working satisfactorily.
Conns internally secure.</column>
<column name="MaintLogID1">BRMR35023884</column>
</row>
<row>
<column name="Notes">Manual release individual checks on fire doors
completed with no defects, all doors are operating
satisfactorily with no defects.</column>
<column name="MaintLogID1">BRMR35023885</column>
</row>
<row>
<column name="Notes">Rudder angle indicators all satisfactory and
agree with steering gear room.</column>
<column name="MaintLogID1">BRMR35023886</column>
</row>
<row>
<column name="Notes">Equipment operation is satisfactory.
No known or reported defects at this time.</column>
<column name="MaintLogID1">BRMR35023887</column>
</row>
<row>
<column name="Notes">Equipment operation is satisfactory.
There are no known or reported deficiences at this time.
</column>
<column name="MaintLogID1">BRMR35023888</column>
</row>
<row>
<column name="Notes">In order to prove a fault with No.2 monitor,
the original monitor from No.1 put into No.2 posn.
The original monitor for No.2 posn is defective.
Therefore when replacement monitor received this will be installed in the
No.1 posn.
Therefore nav system ref No.1 isolated as unable to use until replacement
monitor recd.</column>
<column name="MaintLogID1">BRMR35023889</column>
</row>
<row>
<column name="Notes">ECDIS No.2 operational with monitor from No.1
Ecdis.
Outpoint both computers require to be on in order for navigators to be able
to utilise the attached
printer.</column>
<column name="MaintLogID1">BRMR35023890</column>
</row>
<row>
<column name="Notes">Equipment operational with no known or
reported deficiencies at this time.</column>
<column name="MaintLogID1">BRMR35023891</column>
</row>
<row>
<column name="Notes">Tested and working satisfactorily</column>
<column name="MaintLogID1">BRMR35023892</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023893</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023894</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023895</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023896</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023897</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35023898</column>
</row>
<row>
<column name="Notes">Completed. All valves found free to
move.</column>
<column name="MaintLogID1">BRMR35023899</column>
</row>
<row>
<column name="Notes">as per routines sheet</column>
<column name="MaintLogID1">BRMR35023900</column>
</row>
<row>
<column name="Notes">as per routines sheet</column>
<column name="MaintLogID1">BRMR35023901</column>
</row>
<row>
<column name="Notes">as per routines sheet
ran as main pump</column>
<column name="MaintLogID1">BRMR35023902</column>
</row>
<row>
<column name="Notes">as per routines sheet</column>
<column name="MaintLogID1">BRMR35023903</column>
</row>
<row>
<column name="Notes">as per routines sheet
A large number of fittings needed retightening due to high
vibration.</column>
<column name="MaintLogID1">BRMR35023904</column>
</row>
<row>
<column name="Notes">This machine not ran as it is under
maintence</column>
<column name="MaintLogID1">BRMR35023905</column>
</row>
<row>
<column name="Notes">Tested with flame soap and meter no leaks
found.</column>
<column name="MaintLogID1">BRMR35023906</column>
</row>
<row>
<column name="Notes">Tested with flame soap and meter no leaks
found.</column>
<column name="MaintLogID1">BRMR35023907</column>
</row>
<row>
<column name="Notes">as per sheet</column>
<column name="MaintLogID1">BRMR35023908</column>
</row>
<row>
<column name="Notes">as per sheet</column>
<column name="MaintLogID1">BRMR35023909</column>
</row>
<row>
<column name="Notes">as per sheet</column>
<column name="MaintLogID1">BRMR35023910</column>
</row>
<row>
<column name="Notes">as per sheet</column>
<column name="MaintLogID1">BRMR35023911</column>
</row>
<row>
<column name="Notes">as per sheet</column>
<column name="MaintLogID1">BRMR35023912</column>
</row>
<row>
<column name="Notes">Alarm activated, on inspection sintered filter
found dirty and valve plug appeared to be less magnetic than a new spare +
o ring
no longer fit for use.
new valve plug and o-ring fitted</column>
<column name="MaintLogID1">BRMR35023913</column>
</row>
<row>
<column name="Notes">Routes 7 and 11 tested satisfactorily.
Earlier in the week Ref: Zone 6 Smoke Detector 42 issued a fault alarm (NO
ANSWER)
Replaced This head from spares and set ID address-tested and satisfactory.
ROB=13
Unable to put used spare into AMOS on this report Cheng advised
accordingly</column>
<column name="MaintLogID1">BRMR35023914</column>
</row>
<row>
<column name="Notes">Not tested at BP instruction elevator out of
service</column>
<column name="MaintLogID1">BRMR35023915</column>
</row>
<row>
<column name="Notes">All lights operational, used at suez.
During recent meggar excercise some lights on foremast require remedial
action when out of port</column>
<column name="MaintLogID1">BRMR35023916</column>
</row>
<row>
<column name="Notes">Only VHF DSC tested, 3/o effected and ok
Awaiting transmitting aerial for MF/HF</column>
<column name="MaintLogID1">BRMR35023917</column>
</row>
<row>
<column name="Notes">Rudder angle operation satisfactory on all
units and corresponds to actual rudder angle.
Linkages are satisfactory</column>
<column name="MaintLogID1">BRMR35023918</column>
</row>
<row>
<column name="Notes">2 pce hospital alarms tested satisfactorily.
alarm audible from CCR console and registers on alarm printer</column>
<column name="MaintLogID1">BRMR35023919</column>
</row>
<row>
<column name="Notes">3 pce locked in alarms tested satisfactorily.
Alarm sounds on CCR console and registers on alarm printer.
Lamped up as reqd.</column>
<column name="MaintLogID1">BRMR35023920</column>
</row>
<row>
<column name="Notes">test</column>
<column name="MaintLogID1">BRMR35023921</column>
</row>
<row>
<column name="Notes">All grease ponits greased with HT2.
12/02/07</column>
<column name="MaintLogID1">BRMR35023922</column>
</row>
<row>
<column name="Notes">Compressor run.
27.5 bar - 30 bar = 10mins
9/2/07</column>
<column name="MaintLogID1">BRMR35023923</column>
</row>
<row>
<column name="Notes">all dampers operated no problems
10/02/07</column>
<column name="MaintLogID1">BRMR35023924</column>
</row>
<row>
<column name="Notes">all pumps and motors moved all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023925</column>
</row>
<row>
<column name="Notes">lifeboat checked and run all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023926</column>
</row>
<row>
<column name="Notes">lifeboat checked and run all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023927</column>
</row>
<row>
<column name="Notes">photo resister cleaned with damp cloth all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023928</column>
</row>
<row>
<column name="Notes">high oil content alarm activation all ok
10/02/07
</column>
<column name="MaintLogID1">BRMR35023929</column>
</row>
<row>
<column name="Notes">compressors c/o on ias
10/02/07</column>
<column name="MaintLogID1">BRMR35023930</column>
</row>
<row>
<column name="Notes">compressor c/o on ias
10/02/07</column>
<column name="MaintLogID1">BRMR35023931</column>
</row>
<row>
<column name="Notes">two bags dosed into sewage systm.
10/02/07</column>
<column name="MaintLogID1">BRMR35023932</column>
</row>
<row>
<column name="Notes">rescue boat engine run and checked all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023933</column>
</row>
<row>
<column name="Notes">lifeboat engine ran and checked all ok.
10/02/07</column>
<column name="MaintLogID1">BRMR35023934</column>
</row>
<row>
<column name="Notes">lifeboat engine ran and checked all ok
10/02/07</column>
<column name="MaintLogID1">BRMR35023935</column>
</row>
<row>
<column name="Notes">hoses tested as per rotoation. all ok no
defects found
10/02/07</column>
<column name="MaintLogID1">BRMR35023936</column>
</row>
<row>
<column name="Notes">high oil content alarm activation good. no
problems
10/02/07</column>
<column name="MaintLogID1">BRMR35023937</column>
</row>
<row>
<column name="Notes">Rudder bonding cable satisfactory.
Cleaned shaft earthing device slip ring of deposits with electrical
cleaner.
Removed brushes and cleaned, brush length satisfactory.</column>
<column name="MaintLogID1">BRMR35023938</column>
</row>
<row>
<column name="Notes">GMDSS station has one deficiency-awaiting a
replacement transmitting aerial for MF/HF system
otherwise all equipment satisfactory and log book entries being made as per
requirements.</column>
<column name="MaintLogID1">BRMR35023939</column>
</row>
<row>
<column name="Notes">Equipment operation is satisfactory with no
known or reported deficiencies at this time.</column>
<column name="MaintLogID1">BRMR35023940</column>
</row>
<row>
<column name="Notes">Genny ran onload in parallel with TA load
828kw
Log taken</column>
<column name="MaintLogID1">BRMR35023941</column>
</row>
<row>
<column name="Notes">Genny ran off load for 20mins
Manual Start</column>
<column name="MaintLogID1">BRMR35023942</column>
</row>
<row>
<column name="Notes">Feed p/p ran in parallel with duty
pump</column>
<column name="MaintLogID1">BRMR35023943</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35023944</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35023945</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35023946</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35023947</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked and topped up </column>
<column name="MaintLogID1">BRMR35023948</column>
</row>
<row>
<column name="Notes">All manual valves operated through range
all ok</column>
<column name="MaintLogID1">BRMR35023949</column>
</row>
<row>
<column name="Notes">All sets inspected
All bottle pressures check, all ok</column>
<column name="MaintLogID1">BRMR35023950</column>
</row>
<row>
<column name="Notes">Fire pump ran on test, Manual start</column>
<column name="MaintLogID1">BRMR35023951</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35023952</column>
</row>
<row>
<column name="Notes">Feed pump ran in parallel with duty
pump</column>
<column name="MaintLogID1">BRMR35023953</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 65A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC4N(80) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
The contactor SC1N(26) contacts fixed/moving satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater operation satisfactory..
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
After above work Fan placed back in service ready for sailing from
Damietta.
</column>
<column name="MaintLogID1">BRMR35023954</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 4.5A and consistenent with the red spot marking, and
indicator on
front panel mounted meter.
The main contactor SC05(13) contacts fixed/moving all in good condition..
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater operational satisfactory.
Motor Terminal box outer cover removed for inspection.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure
no sign of any overheating..
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35023955</column>
</row>
<row>
<column name="Notes">Piston v/v replaced (part No 14)
Set pumped up to 200bar and leaked tested
Set returned to service</column>
<column name="MaintLogID1">BRMR35023956</column>
</row>
<row>
<column name="Notes">All system filters removed and cleaned
No build up found on filer mesh
High P.A.P filter found slightly crushed</column>
<column name="MaintLogID1">BRMR35023957</column>
</row>
<row>
<column name="Notes">All system filters removed and cleaned
No build up found on filer mesh
High P.A.P filter found slightly crushed</column>
<column name="MaintLogID1">BRMR35023958</column>
</row>
<row>
<column name="Notes">Probes removed and cleaned
Tests carried out as per pm
Solinoid valves operated correctly</column>
<column name="MaintLogID1">BRMR35023959</column>
</row>
<row>
<column name="Notes">Probes removed and cleaned
Tests carried out as per pm
Solinoid valves operated correctly</column>
<column name="MaintLogID1">BRMR35023960</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023961</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023962</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023963</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023964</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023965</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023966</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023967</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023968</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023969</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023970</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023971</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023972</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023973</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023974</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023975</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023976</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023977</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023978</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023979</column>
</row>
<row>
<column name="Notes">All cleaned as per pm.</column>
<column name="MaintLogID1">BRMR35023980</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023981</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023982</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023983</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023984</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35023985</column>
</row>
<row>
<column name="Notes">There is currently a problem with the conning
monitor, which has frozen.
No alarms from the conning monitor are being sent to the IAS and watchcall.
Deadman alarm operates correctly on the bridge, but the alarm does not
transfer to the IAS/watchcall.
Watchcall system tested for calling duty and all navigators, and tested on
an external alarm and
functioning correctly, however it will not activate on any alarms sent
through the conning monitor
system.
ETO investigating.</column>
<column name="MaintLogID1">BRMR35023986</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023987</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023988</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023989</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023990</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023991</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023992</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023993</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023994</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023995</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023996</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023997</column>
</row>
<row>
<column name="Notes">pm complete as per work order.ok</column>
<column name="MaintLogID1">BRMR35023998</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35023999</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024000</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024001</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024002</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024003</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024004</column>
</row>
<row>
<column name="Notes">All alarms and trips functioning correctly.
Purifier Sludge tank level alarm tested and working correctly</column>
<column name="MaintLogID1">BRMR35024005</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024006</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024007</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024008</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024009</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024010</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024011</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024012</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024013</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024014</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024015</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024016</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024017</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024018</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024019</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024020</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024021</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024022</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024023</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024024</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024025</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024026</column>
</row>
<row>
<column name="Notes">Completed
Bulb changed for new and meter set in Test function and adjusted to Zero.
Shutter closed and meter observed to deflect to 5% - as per the manual.
Shutter opened, meter put back to measure mode and setup to read 0.5% with
Boiler on Full Gas, at MCR</column>
<column name="MaintLogID1">BRMR35024027</column>
</row>
<row>
<column name="Notes">Completed
Bulb changed for new and meter set in Test function and adjusted to Zero.
Shutter closed and meter observed to deflect to 5% - as per the manual.
Shutter opened, meter put back to measure mode and setup to read 0.5% with
Boiler on Full Gas, at MCR</column>
<column name="MaintLogID1">BRMR35024028</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024029</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024030</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024031</column>
</row>
<row>
<column name="Notes">Calibrated, tested, and working
satisfactorily</column>
<column name="MaintLogID1">BRMR35024032</column>
</row>
<row>
<column name="Notes">Completed as per work instruction. Light
operational.</column>
<column name="MaintLogID1">BRMR35024033</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024034</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024035</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024036</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024037</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024038</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024039</column>
</row>
<row>
<column name="Notes">Completed as per work instruction, First Aid
Kits erplenished as required</column>
<column name="MaintLogID1">BRMR35024040</column>
</row>
<row>
<column name="Notes">Completed as per work instruction, All
resusipac and medical O2 bottled pressure acceptable.</column>
<column name="MaintLogID1">BRMR35024041</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024042</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024043</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024044</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024045</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024046</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024047</column>
</row>
<row>
<column name="Notes">Following sections of SOPEP replaced:
(1) Appendix 1 - List of National Operational Contact Points (MSC-MEPC.6-
Circ.1 Annex 2 - 31/12/06)
(2) Appendix 1 - List of Responsible National Contacts (21/11/06)
(3) Amendment sheet)
Hours:
Local 29200
IAS 29263</column>
<column name="MaintLogID1">BRMR35024073</column>
</row>
<row>
<column name="Notes">Completed.
Wear Pattern fine and amount of wear minimal.
Carried out with 2000hr Intermediate Service.
Hours:
Local 29200
IAS 29263</column>
<column name="MaintLogID1">BRMR35024074</column>
</row>
<row>
<column name="Notes">Purifier stripped and cleaned as per Manual.
Light fouling only found.
Lube oil supply pump No.1 Strainer cleaned - medium fouling noted.
Suction pressure now half previous value.
Disc Stack pressure found too low. No. of discs found to be 47 above
divider, 52 below.
Manual states 51 above, 52 below for new supply.
4 disks added to top but pressure found too high, found 2 to give correct
tension - see manual page 61.
Now 49 Discs above divider, 52 below.
Frame feet replaced with new as noted not done at 3 year Major service as
awaiting parts.
See manual page 55.
Stock Checked and service kits made up where possible. Updated numbers
entered in AMOS.
Hours:
Local 29200
IAS 29263</column>
<column name="MaintLogID1">BRMR35024075</column>
</row>
<row>
<column name="Notes">Withdrawn from service, Not inspected at this
time.
</column>
<column name="MaintLogID1">BRMR35024076</column>
</row>
<row>
<column name="Notes">This unit is out of order and has not been
operated since last chlorinated.
</column>
<column name="MaintLogID1">BRMR35024077</column>
</row>
<row>
<column name="Notes">Spare parts have arrived to do this work.
However the units are performing perfectly, and vibration analysis reveales
no problems.
Oil is changed every two months, so it is decided not to overhaul at this
time.
</column>
<column name="MaintLogID1">BRMR35024078</column>
</row>
<row>
<column name="Notes">Oil changed bi-monthly, vibration monitoring
reveals no hidden problems.
Machinery working just fine with no leaks. Therefore it has been decided to
do no work at this time.
</column>
<column name="MaintLogID1">BRMR35024079</column>
</row>
<row>
<column name="Notes">Completed as per work order, Works normally.
</column>
<column name="MaintLogID1">BRMR35024080</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024081</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024082</column>
</row>
<row>
<column name="Notes">D/G ran off load (20mins) All readings
normal,
Still awaiting jkt wtr low press alarm switch
Electric start.</column>
<column name="MaintLogID1">BRMR35024083</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024084</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024085</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024086</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024087</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked and topped up </column>
<column name="MaintLogID1">BRMR35024088</column>
</row>
<row>
<column name="Notes">Genny ran onload in parallel with TA load
1028kw
Log taken</column>
<column name="MaintLogID1">BRMR35024089</column>
</row>
<row>
<column name="Notes">All manual valves operated through
range</column>
<column name="MaintLogID1">BRMR35024090</column>
</row>
<row>
<column name="Notes">All sets inspected and bottles pressures
checked</column>
<column name="MaintLogID1">BRMR35024091</column>
</row>
<row>
<column name="Notes">Pump ran on test
Started from the bridge
All pressures and temperatures normal </column>
<column name="MaintLogID1">BRMR35024092</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024093</column>
</row>
<row>
<column name="Notes">Feed pump ran in parallel with number 1
Leakage observed from outboard seal
</column>
<column name="MaintLogID1">BRMR35024094</column>
</row>
<row>
<column name="Notes">T/A lube oil duplex changed over and filter
checked, small quantity of sludge removed from the bottom of the filter
</column>
<column name="MaintLogID1">BRMR35024095</column>
</row>
<row>
<column name="Notes">Turning gear gear box oil changed. Gear box
flushed and re-filled no deposits found at this time.</column>
<column name="MaintLogID1">BRMR35024096</column>
</row>
<row>
<column name="Notes">Completed as per PM. Approx 1.8 ltrs GRXP 680
was required to fill the coupling as per the instruction book (MM7
Publication MM-21)
Oil removed was found clean with no dirt or deposits.</column>
<column name="MaintLogID1">BRMR35024097</column>
</row>
<row>
<column name="Notes">Completed as per pm oil drained, unit flushed
and re-fill
hrs 23,726</column>
<column name="MaintLogID1">BRMR35024098</column>
</row>
<row>
<column name="Notes">Routes 20,21,23 successfully tested.</column>
<column name="MaintLogID1">BRMR35024099</column>
</row>
<row>
<column name="Notes">Not Tested as out of service according to BP
instructions</column>
<column name="MaintLogID1">BRMR35024100</column>
</row>
<row>
<column name="Notes">External Lighting tested satisfactorily.
As previously reported the foremast insulation Readings were causing reason
for concern.
This has been investigated and an order for spare parts for the floodlights
has been given to Cheng,
basically the majority of floodlights require replacement connection boxes
with integral igniter units
and possibly replacement gaskets for the glass.
The lights must be removed from the foremast and workshop overhauled when
spare parts received as
presently none are available onboard, this is NOT a job that can be done in
situ.
Therefore lights being maintained at whatever the best insulation can be
achieved in the absence of
spare parts, should any not be able to be maintained above say 1 Meg they
will be disconnected.</column>
<column name="MaintLogID1">BRMR35024101</column>
</row>
<row>
<column name="Notes">As previously reported no replacement antenna
therefore no MF/HF DSC testing.
Nav Offs trying to test i discover, explain in detail and show them there
is NO aerial connected, and to
stop this practice until we have a new aerial installed.
Outpoint they will cause damage due to standing wave ratio being
incorrect.</column>
<column name="MaintLogID1">BRMR35024102</column>
</row>
<row>
<column name="Notes">Rudder angle indicators accurate.
Ceiling unit accurate up to 30 deg rudder. (30 max limit on this item)
Linkages all ok</column>
<column name="MaintLogID1">BRMR35024103</column>
</row>
<row>
<column name="Notes">2 pce Hospital call alarms tested
satisfactorily.
Alarm operates both audibly and registers on CCR printer within the
CCR</column>
<column name="MaintLogID1">BRMR35024104</column>
</row>
<row>
<column name="Notes">Meat Room, Dairy Room, Flour Room locked in
alarms tested ok, indicator lamps on activation points
all illuminated. Alarm sounds audibly and registers on CCR printer within
the confines of the CCR.</column>
<column name="MaintLogID1">BRMR35024105</column>
</row>
<row>
<column name="Notes">Battery check on float charge.
Indicated 27.3V charge current in float mode: 2.4A
Actual measured voltage on batteries: 27.43V
Cell Voltages:-
1: 2.27V
2: 2.32V
3: 2.27V
4: 2.27V
5: 2.26V
6: 2.27V
7: 2.28V
8: 2.26V
9: 2.32V
10: 2.32V
11: 2.27V
12: 2.27V</column>
<column name="MaintLogID1">BRMR35024106</column>
</row>
<row>
<column name="Notes">No reported defects in any laundry.
All tumbledryers cleaned of dust/debri, find in all cases when debri tray
at bottom of machines removed
the microswitch which difficult to see is covered in fluff debri, brushed
clean on every machine.
door interlocks operational on all machines.
earth leakage trip on all machines operational.
</column>
<column name="MaintLogID1">BRMR35024107</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024108</column>
</row>
<row>
<column name="Notes">Completed, no defects.</column>
<column name="MaintLogID1">BRMR35024109</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024110</column>
</row>
<row>
<column name="Notes">Complete.
</column>
<column name="MaintLogID1">BRMR35024111</column>
</row>
<row>
<column name="Notes">Completed as per w/o.</column>
<column name="MaintLogID1">BRMR35024112</column>
</row>
<row>
<column name="Notes">Completed as per WO.
</column>
<column name="MaintLogID1">BRMR35024113</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024114</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024115</column>
</row>
<row>
<column name="Notes">Not Done This Week, ER Watch Keeping.
</column>
<column name="MaintLogID1">BRMR35024116</column>
</row>
<row>
<column name="Notes">Completed as per WO.
</column>
<column name="MaintLogID1">BRMR35024117</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024118</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024119</column>
</row>
<row>
<column name="Notes">Done.
</column>
<column name="MaintLogID1">BRMR35024120</column>
</row>
<row>
<column name="Notes">Leak mech seal O/B comp. To investigate.
</column>
<column name="MaintLogID1">BRMR35024121</column>
</row>
<row>
<column name="Notes">Tested and working satisfactorily
Watchcall tested and deadman tested.
All ok</column>
<column name="MaintLogID1">BRMR35024122</column>
</row>
<row>
<column name="Notes">Conning Display
Conning Computers ROS-1 & ROS-2
Konsberg OS-SVC 8 (Bridge) & IAS System
Initially reported that Conning Display had lost all the input data on the
right hand side of the conning screen:-
ie: Dist to WOP
Time to WOP
Bearing to WOP
XTE,GPS.In Command, Auto Pilot etc, etc etc.
Unit frozen up during suez transit
Alarm for no speed input.(2X7 Com Serial Line Ship Speed alarm displayed)
IAS system
Displaying communication alarms (Modebus)
PCU-03 INS- Mbread1 alarm
PCU-03 INS-Mbread2 Alarm
PCU-03 INS-MBWrite
Bridge Alarms showing no value of input and not alarming, ie nav lt
failure.
Findings:
Radars set to wrong LAN - reset to DEFAULT and info returned to righthand
side data on conning screen.
Checking ROS 1 & 2 output connections, which found ok, but on rebooting
ROS1 shows floppy disc drive failure,cheng sets boot priority floppy drive
to low priority & on rebooting observed the IAS modebus alarms clear
and then again comeback later, further reboot and clear again.
Floppy disc drive to be ordered for Ros1
Auto start and stop functions tested with all 3 compressors in all 3
priorities - no problems encountered.
High air temp warning alarm activated at 105 degrees C and compressor
tripped at 110 Degrees C.
Air resevoir low pressure alarms not tested on this occasion as they were
tested under MER/07/00180
All satisfactory.</column>
<column name="MaintLogID1">BRMR35024205</column>
</row>
<row>
<column name="Notes">Completed as per work instruction</column>
<column name="MaintLogID1">BRMR35024206</column>
</row>
<row>
<column name="Notes">Local procedure followed, hot filter
cleaned.</column>
<column name="MaintLogID1">BRMR35024207</column>
</row>
<row>
<column name="Notes">Completed as per work instruction. The
following nozzles found blocked with broken shells and to a far
lesser extent with scale. These cleared.
Port Manifold 2
Starboard manifold 1
No 1 Dome 7
Port Lifeboat 2
Starboard Lifeboat 1</column>
<column name="MaintLogID1">BRMR35024208</column>
</row>
<row>
<column name="Notes">Dryers changed over. STBD dryer NIU</column>
<column name="MaintLogID1">BRMR35024209</column>
</row>
<row>
<column name="Notes">compressor priorities changed, now
No.1 1
No.2 3
No.3 2</column>
<column name="MaintLogID1">BRMR35024210</column>
</row>
<row>
<column name="Notes">compressor priorities changed, now
No.1 1
No.2 3
No.3 2</column>
<column name="MaintLogID1">BRMR35024211</column>
</row>
<row>
<column name="Notes">compressor priorities changed, now
No.1 1
No.2 3
No.3 2</column>
<column name="MaintLogID1">BRMR35024212</column>
</row>
<row>
<column name="Notes">Dryers changed over, STBD dryer NIU.</column>
<column name="MaintLogID1">BRMR35024213</column>
</row>
<row>
<column name="Notes">D/Gen starting air compressors changed over.
No.2 now lead. Compressor operation satisfactory.</column>
<column name="MaintLogID1">BRMR35024214</column>
</row>
<row>
<column name="Notes">D/Gen starting air compressors changed over.
No.2 now lead. Compressor operation satisfactory.</column>
<column name="MaintLogID1">BRMR35024215</column>
</row>
<row>
<column name="Notes">2 bags bi-augmentation culture flushed down
bridge toilet.</column>
<column name="MaintLogID1">BRMR35024216</column>
</row>
<row>
<column name="Notes">Compressor in satisfactory condition. Ran on
test with no problems.</column>
<column name="MaintLogID1">BRMR35024217</column>
</row>
<row>
<column name="Notes">Fire flaps operated - fully operational.
Returned to standby conditon.</column>
<column name="MaintLogID1">BRMR35024218</column>
</row>
<row>
<column name="Notes">Hoses tested in rotation. no leaks
found.</column>
<column name="MaintLogID1">BRMR35024219</column>
</row>
<row>
<column name="Notes">Bilge oil monitor tested. Alarm sounds at
15ppm and automatic v/v change over occurs - fully operational.</column>
<column name="MaintLogID1">BRMR35024220</column>
</row>
<row>
<column name="Notes">Deep fat fryer
starboard oil heating well had been disabled due to faulty safety
thermostat.
Removed and replaced both safety and working thermostats in this starboard
heating well. (New replacements recd singapore)
Port side heating well whilst working at time, both safety and working
thermostats were changed for good measure.
Reconnected three phase supply to stbd heating well.
Tested satisfactory operation.
Order given to Cheng for new set of thermostats, for spares when received.
</column>
<column name="MaintLogID1">BRMR35024221</column>
</row>
<row>
<column name="Notes">Idle machinery roatated. All free - no
problems observed.</column>
<column name="MaintLogID1">BRMR35024222</column>
</row>
<row>
<column name="Notes">Work completed as per P.M.
Vacuumator dismantled and parts cleaned.
Old motor and shaft cleaned to be used in emergency.
Then reassembled onto new motor and shaft, including new mechanical seal.
When reassembled rotated shaft by hand, everything moved freely.
Vacuumarator stored and ready for use.</column>
<column name="MaintLogID1">BRMR35024223</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024224</column>
</row>
<row>
<column name="Notes">Genny ran on load test, 175kw, all ok
Vibration readings taken at this time
New CFW pressure switch also fitted</column>
<column name="MaintLogID1">BRMR35024225</column>
</row>
<row>
<column name="Notes">On load test carried out</column>
<column name="MaintLogID1">BRMR35024226</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024227</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024228</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024229</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024230</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024231</column>
</row>
<row>
<column name="Notes">Load test carried out all
satisfactory</column>
<column name="MaintLogID1">BRMR35024232</column>
</row>
<row>
<column name="Notes">All manual vlv's operated through range
</column>
<column name="MaintLogID1">BRMR35024233</column>
</row>
<row>
<column name="Notes">All sets inspected and bottle pressures
checked</column>
<column name="MaintLogID1">BRMR35024234</column>
</row>
<row>
<column name="Notes">R.O.T all satisfactory, local start</column>
<column name="MaintLogID1">BRMR35024235</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024236</column>
</row>
<row>
<column name="Notes">Ran in parallel with duty feed pump, slight
leakage from outboard mech seal</column>
<column name="MaintLogID1">BRMR35024237</column>
</row>
<row>
<column name="Notes">Anode inspected, 75% of material
remaining</column>
<column name="MaintLogID1">BRMR35024238</column>
</row>
<row>
<column name="Notes">Various Cracks found inside Stbd FW tank.
26.3 25.5
24.3 Lcd mon.
0 5
5.3 Current
Air receiver low pressure alarms not tested as these were done whilst
testing No.2 compressor.
All operational.</column>
<column name="MaintLogID1">BRMR35024309</column>
</row>
<row>
<column name="Notes">All v/vs inspected and operated. No problems
founs - all valves well lubricated.</column>
<column name="MaintLogID1">BRMR35024310</column>
</row>
<row>
<column name="Notes">Completed as per local procedure.</column>
<column name="MaintLogID1">BRMR35024311</column>
</row>
<row>
<column name="Notes">Completed, Port Dryer N.I.U.</column>
<column name="MaintLogID1">BRMR35024312</column>
</row>
<row>
<column name="Notes">Completed, Port Dryer N.I.U.</column>
<column name="MaintLogID1">BRMR35024313</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024314</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024315</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024316</column>
</row>
<row>
<column name="Notes">Completed,
No.1 now lead compressor - no problems observed.</column>
<column name="MaintLogID1">BRMR35024317</column>
</row>
<row>
<column name="Notes">Completed,
No.1 now lead compressor - no problems observed.</column>
<column name="MaintLogID1">BRMR35024318</column>
</row>
<row>
<column name="Notes">2 bags dosed to upper deck port side
toilet.</column>
<column name="MaintLogID1">BRMR35024319</column>
</row>
<row>
<column name="Notes">compressor ran on test with no
problems.</column>
<column name="MaintLogID1">BRMR35024320</column>
</row>
<row>
<column name="Notes">Hoses tested in rotation. no leaks
found.</column>
<column name="MaintLogID1">BRMR35024321</column>
</row>
<row>
<column name="Notes">all flaps operational - no problems.</column>
<column name="MaintLogID1">BRMR35024322</column>
</row>
<row>
<column name="Notes">Tested, fully operational.
This unit recently exchanged in January, the old unit sent back for service
less batteries.
Unit tested satisfactory and in good condition. 0400 01/03/2007
Test details in GMDSS Log Book</column>
<column name="MaintLogID1">BRMR35024325</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory and printer
working ok.
Antennas in good condition and securely mounted.
Performance checked by Link test with LES:317 05/03/2007 0429hrs and good
performance.
Details of this test in GMDSS Logbook.</column>
<column name="MaintLogID1">BRMR35024326</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory and printer
working ok.
Antennas in good condition and securely mounted.
Performance checked by Link test with LES:302 05/03/2007 0429hrs and good
performance.
Details of this test in GMDSS Logbook.</column>
<column name="MaintLogID1">BRMR35024327</column>
</row>
<row>
<column name="Notes">Equipment is operating satisfactorily.
Self test performed and ok -print head in good condition.
Antenna is secure.
Test put in GMDSS Logbook</column>
<column name="MaintLogID1">BRMR35024328</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 480A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC14N(600) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 46,2 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminal box removed, retaining bolts greased.
Space heater outgoing terminals tightened as found loose.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024329</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 1,8A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-05 <13> contacts fixed/moving and arc shutes
all in good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater Supply Feed checked and found to be 57v ./OK
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminals tightened as found loose.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024330</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 95A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-6N(125) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 424 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminals tightened as found loose.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024331</column>
</row>
<row>
<column name="Notes">Battery check on float charge.
Indicated 27.2V charge current in float mode: 2.1A
Actual measured voltage on batteries: 27.39V
Cell Voltages:-
1: 2.27V
2: 2.27V
3: 2.27V
4: 2.28V
5: 2.27V
6: 2.27V
7: 2.28V
8: 2.27V
9: 2.34V
10: 2.34V
11: 2.27V
12: 2.27V</column>
<column name="MaintLogID1">BRMR35024332</column>
</row>
<row>
<column name="Notes">All inspected and ok
System checked and found to be operational with only 2 aft forward facing
speakers (swimming pool area)
All operational.</column>
<column name="MaintLogID1">BRMR35024365</column>
</row>
<row>
<column name="Notes">Both gauge glasses on STBD boiler blown down.
No problems observed.
No leakage.
No leakage.
Thermostat controls, local thermometer & local pressure gauge all fully
operational.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35024368</column>
</row>
<row>
<column name="Notes">Slight fouling on filters, this was removed
and the AIS reading dropped by 0.2%.
Dewpoint satisfactory.
Dewpoint satisfactory.
Purge mufflers not replaced on this occasion as they were in a good state
with less than
0.1 bar backpressure during purge cycle. Spares are also limited.
Hand jacking of the piston v/v does not dump the water as required.
A compressed air connection with an open ended piece of hose the same
legnth as the probe is
connected to a compressed air supply.
The piece of hose is then fitted over the probe and the air cracked on.
This will remove the water from around the probe causing the alarm to
activate. The air is then stopped
and the hose removed.
This method works as the alarm is sounded and the piston v/v dumps
accordingly.
Coating:
Slight Mildew on coating on aft bulkheads in patches. Some dust and dirt
under accesses.
Coating generally in very good condition, a couple of isolated spots of
rust staining.
Bottom level under rescue hatch - Some slight localised rust spots, but
coating generally intact and well attached.
</column>
<column name="MaintLogID1">BRMR35024453</column>
</row>
<row>
<column name="Notes">Suction -0.4 discharge 1.6 bar
Amps 1.5
No leakage from mechanical seal
Holding down bolts checked
Coupling spider inspected, ok
</column>
<column name="MaintLogID1">BRMR35024454</column>
</row>
<row>
<column name="Notes">Not done at this time TDI grease is
semipermanent therefore
re-greasing is only carried out when overhauling bearings on starter once
in every 5-6 years.
makers recomendation, as starter is for emergency usage only overhaul
period should be increase to once in evrey 10-12 years
No TDI grease onboard at this time
Starter operating satisfactory</column>
<column name="MaintLogID1">BRMR35024455</column>
</row>
<row>
<column name="Notes">New Calibration Gas received with BAC 0.05%.
</column>
<column name="MaintLogID1">BRMR35024456</column>
</row>
<row>
<column name="Notes">IOM Marine administration letter of ISM letter
of responsibility received and filed with DOC.</column>
<column name="MaintLogID1">BRMR35024457</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35024458</column>
</row>
<row>
<column name="Notes">As per WO. Rescue boat hydraulic ram arms oil
level not checked at this time.</column>
<column name="MaintLogID1">BRMR35024459</column>
</row>
<row>
<column name="Notes"> Substantively carried out satisfactorily
during rejointing of S/H Safety Valve.</column>
<column name="MaintLogID1">BRMR35024460</column>
</row>
<row>
<column name="Notes">Done except check hydraulic arm oil levels.
</column>
<column name="MaintLogID1">BRMR35024461</column>
</row>
<row>
<column name="Notes">Substantivly completed during shut down for
rejoint of SH safety valve.
</column>
<column name="MaintLogID1">BRMR35024462</column>
</row>
<row>
<column name="Notes">Partially completed during condenser clean and
annode replacement.
</column>
<column name="MaintLogID1">BRMR35024463</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024464</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024465</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024466</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024467</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024468</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024469</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024470</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024471</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024472</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024473</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024474</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024475</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35024476</column>
</row>
<row>
<column name="Notes">Old broken 1st section removed.
New antenna complete installed satisfactorily. </column>
<column name="MaintLogID1">BRMR35024477</column>
</row>
<row>
<column name="Notes">Equipment out of service at BP instructions
therefore this routine NOT effected.</column>
<column name="MaintLogID1">BRMR35024478</column>
</row>
<row>
<column name="Notes">LD1 distribution board below 2 meg ohms.
Lots of problems with lights/ccts.
Removed from foremast the following double HPS lights.
Port Lower aft facing (4A1A + 4A1B, Stbd forward facing 2nd level fm 1st
platform LD1-1B1A
+ LD1-1B1B, Portside lower platform LD1-1A1A +LD-1A1B
The junction boxes with integral igniter units and seals were replaced with
spares received at Spore
17th Feb, ROB=NIL
Remainder of other lights-particularly the doubles ( 2 x 400W HPS) are
suffering from weather ingress
in that every time it rains these lights go to earth- no spares to fix.
Spares being ordered via cheng.
The junction boxes with igniter are cracking and going brittle and the
seals perishing.
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024510</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024511</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024512</column>
</row>
<row>
<column name="Notes">Completed, No.2 now Lead compressor.</column>
<column name="MaintLogID1">BRMR35024513</column>
</row>
<row>
<column name="Notes">Completed, No.2 now Lead compressor.</column>
<column name="MaintLogID1">BRMR35024514</column>
</row>
<row>
<column name="Notes">completed.</column>
<column name="MaintLogID1">BRMR35024515</column>
</row>
<row>
<column name="Notes">Completed, all fully operational.</column>
<column name="MaintLogID1">BRMR35024516</column>
</row>
<row>
<column name="Notes">Tested in rotation.</column>
<column name="MaintLogID1">BRMR35024517</column>
</row>
<row>
<column name="Notes">Flaps fully operational.</column>
<column name="MaintLogID1">BRMR35024518</column>
</row>
<row>
<column name="Notes">Fully operational,
Oil change not required this time as filter has another 1190hrs to
go</column>
<column name="MaintLogID1">BRMR35024527</column>
</row>
<row>
<column name="Notes">New PM resetting the runhours.
Last seperator change carried out at 8894hrs.</column>
<column name="MaintLogID1">BRMR35024528</column>
</row>
<row>
<column name="Notes">New pm.
Counter when last done was 6924</column>
<column name="MaintLogID1">BRMR35024529</column>
</row>
<row>
<column name="Notes">Upon inspection, In found grablines on the
four lifebouys aft of the accomodation to be showing signs of wear
and I replaced these immediately.
The others were, if not quite worn, then certainly far from new and rigged
in an inappropriate manner
i.e. no double knots and quite tight loops.
Therefore all grablines were replaced, the bouys cleaned and lettering
touched up.</column>
<column name="MaintLogID1">BRMR35024530</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024531</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024532</column>
</row>
<row>
<column name="Notes">DSAS Purplefinder
equipment located at top of main mast, battery pack renewed.
Unit tested by capt/CSO and satisfactory operation.
Next changeout in 2 years time-16/03/2009</column>
<column name="MaintLogID1">BRMR35024533</column>
</row>
<row>
<column name="Notes"> UHF units on the brige, ccr and ecr checked
and found in good condition. They were dust free and didn't need
cleaning. Nitros antenna's in the cargo motor room, passage way (stbd
and port side), bosun store, E/R (2ND-DK 3RD DK, 4TH DK and floor) and S/G
room opened and inspected. Antenna's wasent painted and found in good
and operational conditon. Connections were tight.
Antennas for base stations located on monkety island and foremast in good
condition.
</column>
<column name="MaintLogID1">BRMR35024534</column>
</row>
<row>
<column name="Notes">DSAS Push Button tested (WH) after change out
of DSAS Battery.
Unit functioned correctly.
Result Filed in HSSE-SECURITY-SECURITY-GLOBALCD-04</column>
<column name="MaintLogID1">BRMR35024535</column>
</row>
<row>
<column name="Notes">Occaisional re-booting of system from A Deck
required. Gauges generally working OK though.</column>
<column name="MaintLogID1">BRMR35024536</column>
</row>
<row>
<column name="Notes">Some webbing strops found since last
inspection and colour coded.
Some shackles required painting green after inspection.
Scafftag system to be applied to all lifting gear. Chain blocks already
have scafftags. Insufficient tags for all strops, rest to be applied on
delivery of new order.
</column>
<column name="MaintLogID1">BRMR35024537</column>
</row>
<row>
<column name="Notes">Plasters replaced in ER box.
Inventory entered on new LE West UK MCA Scales Spreadsheet.</column>
<column name="MaintLogID1">BRMR35024543</column>
</row>
<row>
<column name="Notes">Leakage from unit tracked down to mech seal.
Seal in good order however the O-Rings were perished
and cracked. Variouse rubber seals replaced and AMOS ammended.
Additioanally the flexable coupling elements were replaced and AMOS
ammended accordingly.
The leaky gauge glass upper link pipe on thr oil reciever was also remade.
</column>
<column name="MaintLogID1">BRMR35024544</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024545</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024546</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024547</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024548</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024549</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024550</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024551</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024552</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024553</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024554</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024555</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024556</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.
</column>
<column name="MaintLogID1">BRMR35024557</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024558</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024559</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024560</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024561</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024562</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024563</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024564</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024565</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024566</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024567</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024568</column>
</row>
<row>
<column name="Notes">Work completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024569</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 2A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-1N(26) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 1600 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Space heater terminal box removed, retaining bolts greased.
Space heater outgoing terminals tightened as found loose.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024570</column>
</row>
<row>
<column name="Notes">Light checked and working OK.</column>
<column name="MaintLogID1">BRMR35024572</column>
</row>
<row>
<column name="Notes">Wheel keys purchased locally through chandlers
SINWA at Singapore, as per the quanties set out in the FIN.</column>
<column name="MaintLogID1">BRMR35024573</column>
</row>
<row>
<column name="Notes">The stretchers are all in good condition and
correctly stowed.
All accessories for the Paraguard Stretcher are accounted for and in good
condition, except for the two optional extra shoulder harnesses with which
this vessel was not supplied.</column>
<column name="MaintLogID1">BRMR35024574</column>
</row>
<row>
<column name="Notes">Controlled publications checked as per list:
The following e-mail was sent to Lillie and gilley to update the list:
Quote:
Good Day,
CD 8.4 IP001 HM40 Guidelines for Crude oil Washing and heating of tanks
----------
----------
----------
Please can you arrange to have the required publications as listed above to
be sent out with the next NECAPs
Best Regards
Nicholas Bourke</column>
<column name="MaintLogID1">BRMR35024575</column>
</row>
<row>
<column name="Notes">Structure:
In Good Condition - No Cracks or deformations noted.
Cold spotting not carried out due to cargo tanks being in warm condition.
Coating:
Slight Mildew on coating on aft bulkheads in patches. Some dust and dirt
under accesses.
Coating generally in very good condition, a couple of isolated spots of
rust staining.
Bottom level under rescue hatch - Some slight localised rust spots, but
coating generally intact and well attached, thin film of dried mud in
parts.
Coating:
Slight Mildew on coating on aft bulkheads in patches. Some dust and dirt
under accesses.
Coating in very good condition, a couple of isolated spots of rust
staining.
Bottom level under rescue hatch - Some slight localised rust spots, but
coating generally intact and well attached, thin film of dried mud in
parts.
Coating:
In excellent condition. Some past mildew formation evident in areas around
vapour dome.
No breakdown of coating evident.
</column>
<column name="MaintLogID1">BRMR35024578</column>
</row>
<row>
<column name="Notes">Structure:
In Good Condition - No Cracks or deformations noted.
Cold spotting not carried out due to cargo tanks being in warm condition.
Coating:
Slight Mildew on coating on deck in patches. Some evidence of small leaking
from deck access plates.
Coating in very good condition.
Pipelines and Fittings:
All appear to be in good order.
</column>
<column name="MaintLogID1">BRMR35024579</column>
</row>
<row>
<column name="Notes">PM COMPLETED AS PER WORK ORDER.OK</column>
<column name="MaintLogID1">BRMR35024580</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024581</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024582</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024583</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024584</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024585</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024586</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024587</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024588</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024589</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024590</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024591</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024592</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024593</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024594</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024595</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024596</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024597</column>
</row>
<row>
<column name="Notes">Vacuum pump cut in/out pressures -0.3 to
-0.4bar as the pump is not able to reach -0.5bar without
running for an extended period of time and becoming very hot.
Sewage discharge pump and holding tank pump operate correctly in auto mode
and both high levels
operate fine.</column>
<column name="MaintLogID1">BRMR35024598</column>
</row>
<row>
<column name="Notes">Pump inspected, all satisfactory. Nothing to
report.</column>
<column name="MaintLogID1">BRMR35024599</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024600</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024601</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024602</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024603</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024604</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35024605</column>
</row>
<row>
<column name="Notes">Completed, No.1 NIU, Dew point -85 Deg
C</column>
<column name="MaintLogID1">BRMR35024606</column>
</row>
<row>
<column name="Notes">Completed, No.1 NIU, Dew point -85 Deg
C</column>
<column name="MaintLogID1">BRMR35024607</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35024608</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35024609</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35024610</column>
</row>
<row>
<column name="Notes">Completed, No. 1 now lead M/C.</column>
<column name="MaintLogID1">BRMR35024611</column>
</row>
<row>
<column name="Notes">Completed, No. 1 now lead M/C.</column>
<column name="MaintLogID1">BRMR35024612</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35024613</column>
</row>
<row>
<column name="Notes">Ran on test, all fully operational</column>
<column name="MaintLogID1">BRMR35024614</column>
</row>
<row>
<column name="Notes">Tested in rotation.</column>
<column name="MaintLogID1">BRMR35024615</column>
</row>
<row>
<column name="Notes">All fully operational</column>
<column name="MaintLogID1">BRMR35024616</column>
</row>
<row>
<column name="Notes">All fully operational, 3 - way v/v auto
changeover and alarm activated.</column>
<column name="MaintLogID1">BRMR35024617</column>
</row>
<row>
<column name="Notes">completed</column>
<column name="MaintLogID1">BRMR35024618</column>
</row>
<row>
<column name="Notes">All fully operational. Not completed as per
PM, however.</column>
<column name="MaintLogID1">BRMR35024619</column>
</row>
<row>
<column name="Notes">Anodes found with approx 40% wastage
Recommed re-inspection in approx 6-8 months</column>
<column name="MaintLogID1">BRMR35024620</column>
</row>
<row>
<column name="Notes">Anodes found 100% wasted
New anodes fitted
</column>
<column name="MaintLogID1">BRMR35024621</column>
</row>
<row>
<column name="Notes">Anodes found with approx 50% wastage
Not changed at this time
Recommend re-inspection in 6 month</column>
<column name="MaintLogID1">BRMR35024622</column>
</row>
<row>
<column name="Notes">Anodes found 100% wasted
New Anodes fitted
Recommend re-inspection in 6 month</column>
<column name="MaintLogID1">BRMR35024623</column>
</row>
<row>
<column name="Notes">Governor, drained flushed and re-filled
T/A ran on test all satisfactory
Hrs ctr 21079</column>
<column name="MaintLogID1">BRMR35024624</column>
</row>
<row>
<column name="Notes">Greasing carried out. all linkages and joints
checked</column>
<column name="MaintLogID1">BRMR35024625</column>
</row>
<row>
<column name="Notes">
Item
Alarm Trip Results
Electrical Overspeed
1980 1943
Mechanical Overspeed
2000 1961
Low L.O Pressure
0.06mpa 0.06mpa Operational
D/G Auto Start.
Ok Operational
Low Vacuum Pressure.
-0.05mpa -0.013mpa Operational
Excess Vibration
80um 140um Operational
Rotor Axial Movement.
0.5mm 0.7mm Operational
Hand Trip
Ok Operational
Remote Stop
Ok Operational
Gland Steam Low Pressure
-13.3 Operational
Low L.O sump level.
Ok Operational
Turning gear interlock.
Ok Operational
Priming Pump Auto Start/Stop Cut in 40
Cut Out 100 Kpa 40/100
Air cooler water leakage.
Ok Operational
IAS Turbine Thrust Bearing High 75 c
Operational
IAS Governor End Bearing
75 c Operational
IAS Rear End Bearing
75 c Operational
IAS Gear Pinion Bearing (Turbine end) 75
c Operational
IAS Gear Pinion Bearing (Gen end) 75
c Operational
IAS Wheel Bearing (Turbine end) 75
c Operational
IAS Wheel Bearing (Gen end)
75 c Operational
IAS L.O. Inlet Temp
53 c Operational
IAS D.E Bearing Oil Temp
90c 95c Operational
IAS N.D.E Bearing Oil Temp
90 c 95 c Operational
IAS DE Bearing Temp
90 c 95 c Operational
IAS N.D.E Bearing Temp
90 c 95 c Operational
IAS (R,S,T) Winding Temp
165 c 170 c Operational
IAS Generator Air Outlet Temp
100 105 Operational
Running hours:24332</column>
<column name="MaintLogID1">BRMR35024626</column>
</row>
<row>
<column name="Notes">Item
Alarm Trip Results
Electrical Overspeed
1980 1968
Mechanical Overspeed
2000 2006
Low L.O Pressure
0.06mpa 0.06mpa Operational
D/G Auto Start.
Ok Operational
Low Vacuum Pressure.
-0.05mpa -0.013mpa Operational
Excess Vibration
80um 140um Operational
Rotor Axial Movement.
0.5mm 0.7mm Operational
Hand Trip
Ok Operational
Remote Stop
Ok Operational
Gland Steam Low Pressure
-13.3 Operational
Low L.O sump level.
Ok Operational
Turning gear interlock.
Ok Operational
Priming Pump Auto Start/Stop Cut in 40
Cut Out 100 Kpa 40/100
Air cooler water leakage.
Ok Operational
IAS Turbine Thrust Bearing High 75 c
Operational
IAS Governor End Bearing
75 c Operational
IAS Rear End Bearing
75 c Operational
IAS Gear Pinion Bearing (Turbine end) 75
c Operational
IAS Gear Pinion Bearing (Gen end) 75
c Operational
IAS Wheel Bearing (Turbine end) 75
c Operational
IAS Wheel Bearing (Gen end)
75 c Operational
IAS L.O. Inlet Temp
53 c Operational
IAS D.E Bearing Oil Temp
90c 95c Operational
IAS N.D.E Bearing Oil Temp
90 c 95 c Operational
IAS DE Bearing Temp
90 c 95 c Operational
IAS N.D.E Bearing Temp
90 c 95 c Operational
IAS (R,S,T) Winding Temp
165 c 170 c Operational
IAS Generator Air Outlet Temp
100 105 Operational
Running hours:21102</column>
<column name="MaintLogID1">BRMR35024627</column>
</row>
<row>
<column name="Notes">Electric starter failed to operate
Starter removed and found to be mechanical free to turn
Starter re-fitted and tested a 14volt drop across the batteries was
observed
Batteries unable to supply required power to turn motor
Fire pump started using spring start, all satisfactory
New batteries on order
</column>
<column name="MaintLogID1">BRMR35024628</column>
</row>
<row>
<column name="Notes">All sets inpsected and cleaned, all bottle
pressures checked</column>
<column name="MaintLogID1">BRMR35024629</column>
</row>
<row>
<column name="Notes">All maunal valves operated through
range</column>
<column name="MaintLogID1">BRMR35024630</column>
</row>
<row>
<column name="Notes">Genny ran on load in parallel with number 2
T/A
Log Taken 828 kw
All readings satisfactory</column>
<column name="MaintLogID1">BRMR35024631</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024632</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024633</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024634</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024635</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024636</column>
</row>
<row>
<column name="Notes">Genny ran off load 20mins
Electric start</column>
<column name="MaintLogID1">BRMR35024637</column>
</row>
<row>
<column name="Notes">Ran in parallel with duty feed pump</column>
<column name="MaintLogID1">BRMR35024638</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024639</column>
</row>
<row>
<column name="Notes">Feed pump greasing routine completed OK,
quantity of old grease removed from around nut.</column>
<column name="MaintLogID1">BRMR35024640</column>
</row>
<row>
<column name="Notes">One man bridge alarm tested as per PM routine.
Duty Call and All Call tested on Navig. System.
All satisfactory</column>
<column name="MaintLogID1">BRMR35024641</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024642</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024643</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024644</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024645</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024646</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024647</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024648</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024649</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024650</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024651</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024652</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024653</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024654</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024655</column>
</row>
<row>
<column name="Notes">Equipment out of service at BP instructions
therefore this routine NOT effected.</column>
<column name="MaintLogID1">BRMR35024656</column>
</row>
<row>
<column name="Notes">3 pce locked in alarms tested ok.
Red lamps lamped up as reqd.</column>
<column name="MaintLogID1">BRMR35024657</column>
</row>
<row>
<column name="Notes">3 pce locked in alarms tested ok.
Red lamps lamped up as reqd.</column>
<column name="MaintLogID1">BRMR35024658</column>
</row>
<row>
<column name="Notes">Routs 6,15,18,19,24,25 satisfactorily
done</column>
<column name="MaintLogID1">BRMR35024659</column>
</row>
<row>
<column name="Notes">LD1 distribution board below 2 meg ohms.
The external lighting ref LD1 distribution board suffers from weather
ingress and no spares to fix at
present time.
Prior arrival at port the lights will have to be drained of water and dried
out to minimise earth faults.
</column>
<column name="MaintLogID1">BRMR35024665</column>
</row>
<row>
<column name="Notes">Fan observed whilst running, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35024666</column>
</row>
<row>
<column name="Notes">PM completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024667</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024668</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024669</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35024670</column>
</row>
<row>
<column name="Notes">System salinometer's checked- ADT, auxy
condenser and main condenser probes all OK.
Dearator probe failed - internal electrical connections new probe fitted
New probe on order.
</column>
<column name="MaintLogID1">BRMR35024671</column>
</row>
<row>
<column name="Notes">Probes removed, cleaned, alarm and valve
operation checked
All satisfactory</column>
<column name="MaintLogID1">BRMR35024672</column>
</row>
<row>
<column name="Notes">1. All zones have been fully tested during
this 3 month period.
All zones are fully operational with no known defects.
Zone testing Log is on computer with dates of each zone 1-26 entered.
7. Confirm that the Accomodation Fire door routine I412 has been completed
twice during the last
3 months. All doors fully operational both on Manual/Automatic release-
tested satisfactory.</column>
<column name="MaintLogID1">BRMR35024673</column>
</row>
<row>
<column name="Notes">Unit visually inspected and found ok.
No defects in operation reported at this time.</column>
<column name="MaintLogID1">BRMR35024674</column>
</row>
<row>
<column name="Notes">AIS unit is fully functioning and in good
condition.
There are no known or reported defects from the navigational dept
concerning this item of equipment.
Associated antenna is in good condition and secure.</column>
<column name="MaintLogID1">BRMR35024675</column>
</row>
<row>
<column name="Notes">The communal aerial system is in working
condition.
Visually units look good and wiring secure.
There are no known or reported defects.
Antenna units associated with equipment are in good condition and
secure.</column>
<column name="MaintLogID1">BRMR35024676</column>
</row>
<row>
<column name="Notes">External inspection of equipment would appear
satisfactory condition.
There are no known or reported defects in the operation of this
equipment.</column>
<column name="MaintLogID1">BRMR35024677</column>
</row>
<row>
<column name="Notes">Feed pump tested, all OK. Discharge pressure
90Bar. </column>
<column name="MaintLogID1">BRMR35024678</column>
</row>
<row>
<column name="Notes">Pressure transmitters tested with Jofre
throughout range. Very small deviation but linear on Press Trx.
Going a bit wider for the vacuum trx. at extreme vacuum only; Though
fine at normal working ranges.
Pulse lines all good. Transmitter isolator valve for MM236 needs to be
replaced. Seat corroded, needed
to shut V/V on P/P to retain test pressure. Pretty much as last time though
I havnt got round to
finding a new valve though.</column>
<column name="MaintLogID1">BRMR35024679</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35024680</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per work
order.</column>
<column name="MaintLogID1">BRMR35024681</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per work
order.</column>
<column name="MaintLogID1">BRMR35024682</column>
</row>
<row>
<column name="Notes">Inspection completed as per P.M
Found satisfactory.</column>
<column name="MaintLogID1">BRMR35024683</column>
</row>
<row>
<column name="Notes">Work completed as per P.M
All found satisfactory.</column>
<column name="MaintLogID1">BRMR35024684</column>
</row>
<row>
<column name="Notes">Work completed as per P.M
All found satisfactory.</column>
<column name="MaintLogID1">BRMR35024685</column>
</row>
<row>
<column name="Notes">Work completed as per P.M
All found satisfactory.</column>
<column name="MaintLogID1">BRMR35024686</column>
</row>
<row>
<column name="Notes">Work completed as per p.m
Found satisfactory.</column>
<column name="MaintLogID1">BRMR35024687</column>
</row>
<row>
<column name="Notes">Work completed as per P.M</column>
<column name="MaintLogID1">BRMR35024688</column>
</row>
<row>
<column name="Notes">Work completed as per P.M</column>
<column name="MaintLogID1">BRMR35024689</column>
</row>
<row>
<column name="Notes">Work completed as per P.M</column>
<column name="MaintLogID1">BRMR35024690</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 65A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-4N <80> contacts fixed/moving, contacts was
dirty so I clean them up with oil stone, arc shouts are dirty
but in good condision.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024691</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 4.5A and consistenent with the red spot marking, and
indicator on
front panel mounted meter.
The main contactor SC05(13) contacts fixed/moving all in good condition..
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater operational satisfactory.-25V to Windings.
Motor Terminal box- outer cover removed for inspection.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure
no sign of any overheating..
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >100 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024692</column>
</row>
<row>
<column name="Notes">Evaporator control panel and circuit
associated with this pump inspected.
All found in good clean condition and wiring secure.
Contactor 2F2 in good operable condition, overload at 1.6A consistent with
front panel meter indicator.
Wiring found secure and no sign of overheating.
Motor terminal box removed and wiring secure within with good insulation.
Insulation Resistance wrt earth 200 meg ohms.
Cable gland is further proofed for water ingress by use of putty and tape,
as location and mounting is prone to
water leaks.</column>
<column name="MaintLogID1">BRMR35024693</column>
</row>
<row>
<column name="Notes">Fire pump started using spring start, all
satisfactory
Still awaiting new batteries</column>
<column name="MaintLogID1">BRMR35024694</column>
</row>
<row>
<column name="Notes">All sets inpsected and cleaned, all bottle
pressures checked
All satisfactory</column>
<column name="MaintLogID1">BRMR35024695</column>
</row>
<row>
<column name="Notes">All maunal valves operated through
range</column>
<column name="MaintLogID1">BRMR35024696</column>
</row>
<row>
<column name="Notes">Genny ran on load test in parallel with number
2 T/A
All readings satisfactory</column>
<column name="MaintLogID1">BRMR35024697</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024698</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024699</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024700</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024701</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Piston actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024702</column>
</row>
<row>
<column name="Notes">Genny ran off load 20mins
Air start</column>
<column name="MaintLogID1">BRMR35024703</column>
</row>
<row>
<column name="Notes">Ran in parallel with duty feed pump
All satisfactory</column>
<column name="MaintLogID1">BRMR35024704</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024705</column>
</row>
<row>
<column name="Notes">Work order carried out as per PM.
All operational and satisfactory.
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024747</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024748</column>
</row>
<row>
<column name="Notes">Completed as per Pm. The valve can now be
handjacked open without problem.
all operational.</column>
<column name="MaintLogID1">BRMR35024749</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35024750</column>
</row>
<row>
<column name="Notes">Completed, No.2 NIU, Dew point -89 Deg
C</column>
<column name="MaintLogID1">BRMR35024751</column>
</row>
<row>
<column name="Notes">Completed, No.2 NIU, Dew point -89 Deg
C</column>
<column name="MaintLogID1">BRMR35024752</column>
</row>
<row>
<column name="Notes">All flaps operational.</column>
<column name="MaintLogID1">BRMR35024753</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35024754</column>
</row>
<row>
<column name="Notes">Completed, No. 2 now lead m/c</column>
<column name="MaintLogID1">BRMR35024755</column>
</row>
<row>
<column name="Notes">Completed, No. 2 now lead m/c</column>
<column name="MaintLogID1">BRMR35024756</column>
</row>
<row>
<column name="Notes">Boat ran in water, no problems. Fuel topped up
afterwards.
all satisfactory</column>
<column name="MaintLogID1">BRMR35024757</column>
</row>
<row>
<column name="Notes">All manouvering v/v points greased with high
temp. grease.</column>
<column name="MaintLogID1">BRMR35024758</column>
</row>
<row>
<column name="Notes">M/T operated locally on emergency control. No
problems observed, all operational.</column>
<column name="MaintLogID1">BRMR35024759</column>
</row>
<row>
<column name="Notes">All sets inspected and bottles inspected,
No bottles required recharging</column>
<column name="MaintLogID1">BRMR35024760</column>
</row>
<row>
<column name="Notes">All manual valves operated through
range</column>
<column name="MaintLogID1">BRMR35024761</column>
</row>
<row>
<column name="Notes">Diesel Genny ran on load test 728kw
Log taken, all readings satisfactory</column>
<column name="MaintLogID1">BRMR35024762</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024763</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024764</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024765</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024766</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35024767</column>
</row>
<row>
<column name="Notes">Genny ran off load
Electric start used
all satisfactory
</column>
<column name="MaintLogID1">BRMR35024768</column>
</row>
<row>
<column name="Notes">Ran in parellel with duty feed pump</column>
<column name="MaintLogID1">BRMR35024769</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024770</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024771</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024772</column>
</row>
<row>
<column name="Notes">General Inspection of HFO tank. Visually
inspected from above, no entry made.
The tank has been empty since delivery and appears to be in good
condition.</column>
<column name="MaintLogID1">BRMR35024773</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024774</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024775</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024776</column>
</row>
<row>
<column name="Notes">Bi Annual was carried out by Unitor at
Singapore between 10-11th March 2006.
</column>
<column name="MaintLogID1">BRMR35024777</column>
</row>
<row>
<column name="Notes">Completed as per Work Order.</column>
<column name="MaintLogID1">BRMR35024778</column>
</row>
<row>
<column name="Notes">Hand Brake Pump unit removed and overhauled
due to excessive leaking of Hydraulic Oil through gland.
Piston pitted due to exposure to sea air, smoothed with emery, gaskets and
seals replaced and unit re-assembled.
Operating satisftactorily.</column>
<column name="MaintLogID1">BRMR35024783</column>
</row>
<row>
<column name="Notes">Guillotine cushion plates removed descaled,
greased and replaced. One thin plate removed for good. Due to expansion of
other plates from rusting.
Guillotine now operating freely.
</column>
<column name="MaintLogID1">BRMR35024794</column>
</row>
<row>
<column name="Notes">Guillotine cushion plates removed descaled,
greased and replaced. One thin plate removed for good. Due to expansion of
other plates from rusting.
Guillotine now operating freely.
</column>
<column name="MaintLogID1">BRMR35024795</column>
</row>
<row>
<column name="Notes">All correct as per PM
No problems observed.</column>
<column name="MaintLogID1">BRMR35024799</column>
</row>
<row>
<column name="Notes">High level alarms tested and all proved
operational</column>
<column name="MaintLogID1">BRMR35024802</column>
</row>
<row>
<column name="Notes">Fire pump started using spring start, all
satisfactory
Still awaiting new batteries</column>
<column name="MaintLogID1">BRMR35024803</column>
</row>
<row>
<column name="Notes">All sets inpsected and cleaned, all bottle
pressures checked
All satisfactory</column>
<column name="MaintLogID1">BRMR35024804</column>
</row>
<row>
<column name="Notes">Diesel Genny ran on load test 917kw
Log taken, all readings satisfactory</column>
<column name="MaintLogID1">BRMR35024805</column>
</row>
<row>
<column name="Notes">Ran on test, off load
Electric start, all readings normal</column>
<column name="MaintLogID1">BRMR35024806</column>
</row>
<row>
<column name="Notes">Ran in parallel with duty feed pump, all
satisfactory</column>
<column name="MaintLogID1">BRMR35024807</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35024808</column>
</row>
<row>
<column name="Notes">All escape sets checked.
Some minor tears noted on bags used for tank diving operations, but not
affecting the unit.
</column>
<column name="MaintLogID1">BRMR35024811</column>
</row>
<row>
<column name="Notes">Equipment out of service at BP instructions
therefore this routine NOT effected.</column>
<column name="MaintLogID1">BRMR35024812</column>
</row>
<row>
<column name="Notes">Meat, Dairy, Flour room locked in alarms
tested ok.
Audible alarm in CCR and registered on alarm printer satisfactory.
Red indicator lamps all illuminated for ID of push position within
rooms.</column>
<column name="MaintLogID1">BRMR35024813</column>
</row>
<row>
<column name="Notes">Route 1&2 Done</column>
<column name="MaintLogID1">BRMR35024814</column>
</row>
<row>
<column name="Notes">LD1 distribution board below 2 meg ohms.
The external lighting ref LD1 distribution board suffers from weather
ingress and no spares to fix at
present time.
Prior arrival at port the lights will have to be drained of water and dried
out to minimise earth faults.
RX415-
540010021S
590050038RN
590050040RN
All satisifactory</column>
<column name="MaintLogID1">BRMR35024869</column>
</row>
<row>
<column name="Notes">All found satisfactory, cleaned as per pm
</column>
<column name="MaintLogID1">BRMR35024870</column>
</row>
<row>
<column name="Notes">All found satisfactory, cleaned as per pm
</column>
<column name="MaintLogID1">BRMR35024871</column>
</row>
<row>
<column name="Notes">All alarms and trips proved satisfactory,
Feed air high
Equipment restored to initial status and confirmed running</column>
<column name="MaintLogID1">BRMR35024872</column>
</row>
<row>
<column name="Notes">Wires in good condition, still well
greased.</column>
<column name="MaintLogID1">BRMR35024873</column>
</row>
<row>
<column name="Notes">Wires in good condition, still well
greased.</column>
<column name="MaintLogID1">BRMR35024874</column>
</row>
<row>
<column name="Notes">All checked & found satisfactory</column>
<column name="MaintLogID1">BRMR35024875</column>
</row>
<row>
<column name="Notes">System checked all satisfactory</column>
<column name="MaintLogID1">BRMR35024876</column>
</row>
<row>
<column name="Notes">3 Saveall plugs either stuck or have their
chain missing, to be attended to.</column>
<column name="MaintLogID1">BRMR35024877</column>
</row>
<row>
<column name="Notes">Completed as per WO. Grav Tk Alm Tested.
1860ltr in store tk.Oil Bright and clear of wtr.
Filter in black.
</column>
<column name="MaintLogID1">BRMR35024878</column>
</row>
<row>
<column name="Notes">Work Order completed entirely satisfactorily.
</column>
<column name="MaintLogID1">BRMR35024879</column>
</row>
<row>
<column name="Notes">Filters cleaned, Louvres repaired and painted,
Trunk touched up to prevent corrosion
and drains unblocked.</column>
<column name="MaintLogID1">BRMR35024880</column>
</row>
<row>
<column name="Notes">Filters cleaned, Louvres repaired and painted,
Trunk touched up to prevent corrosion
and drains unblocked.</column>
<column name="MaintLogID1">BRMR35024881</column>
</row>
<row>
<column name="Notes">Portside winch forward on focsule (ref motor
No.1)
Starter cover plate removed-bolts replaced with stainless steel ones due
severe weathering of original
mild steel bolts-greased accordingly.
Starter inspected and find in a clean dry condition with no signs of any
cabling overheating and physical
insulation in good order. No signs of any chaffing of the 3 phase cabling.
Wiring throughout the starter is secure.
The starter component mounting plate was found secure and no mounting
fastening fixture had
vibrated loose. The 440V control voltage transformer was found securely
mounted to the mounting
plate, this component having been found loose in this class of ship in the
past.
All electrical components found in good condition on mounting plate and
secure.
The main contactor Telemecanique LC1 F185, the stationary and moving
contacts were removed and
dressed up as found dirty and well pitted, arc shutes cleaned but in good
condition.
These contacts have had 3 years usage and would advise changeout after this
dressing up-order has
been given to Cheng for replacements.
Insulation reading wrt earth starter to motor 300 meg ohms.
The motor terminal box was not removed to check the motor tails at this
time, and within the
terminal box, as experience previously has found that the mounting bolts to
be well seized and are
highly liable to snap in the course of removing them, they are mild
steel/painted.
The Cheng was/has been advised of this fact.
The various lamps,switches etc mounted on the control plate and exposed to
weather are operative
but are weathering and will eventually leak water internally in the future,
due to both rusting and
chemical reaction of the plate holes required to mount the components.
As weather is entering the actual components are suffering from
weathering/chemical reaction and will
also require replacing in the near future, the clue shortly will be when
personnel advise that the
pushbutton switches are prone to sticking, as this will be a direct
consequence of the weathering
process.
</column>
<column name="MaintLogID1">BRMR35024882</column>
</row>
<row>
<column name="Notes">Portside winch forward on focsule (ref motor
No.2)
Starter cover plate removed-bolts replaced with stainless steel ones due
severe weathering of original
mild steel bolts-greased accordingly.
Starter inspected and find in a clean dry condition with no signs of any
cabling overheating and physical
insulation in good order. No signs of any chaffing of the 3 phase cabling.
Wiring throughout the starter is secure.
The starter component mounting plate was found secure and no mounting
fastening fixture had
vibrated loose. The 440V control voltage transformer was found securely
mounted to the mounting
plate, this component having been found loose in this class of ship in the
past.
All electrical components found in good condition on mounting plate and
secure.
The main contactor Telemecanique LC1 F185, the stationary and moving
contacts were removed and
dressed up as found dirty and well pitted, arc shutes cleaned but in good
condition.
These contacts have had 3 years usage and would advise changeout after this
dressing up-order has
been given to Cheng for replacements.
Insulation reading wrt earth starter to motor 300 meg ohms.
The motor terminal box was not removed to check the motor tails at this
time, and within the
terminal box, as experience previously has found that the mounting bolts to
be well seized and are
highly liable to snap in the course of removing them, they are mild
steel/painted.
The Cheng was/has been advised of this fact.
The various lamps,switches etc mounted on the control plate and exposed to
weather are operative
but are weathering and will eventually leak water internally in the future,
due to both rusting and
chemical reaction of the plate holes required to mount the components.
As weather is entering the actual components are suffering from
weathering/chemical reaction and will
also require replacing in the near future, the clue shortly will be when
personnel advise that the
pushbutton switches are prone to sticking, as this will be a direct
consequence of the weathering
process.
The silicone boots covering the start/stop switches ref motor No.2 were
replaced as originals missing
or damaged, the weathering of the actual switches was removed and the
switch bodies vaselined, before
reinstalling on the control plate.
</column>
<column name="MaintLogID1">BRMR35024883</column>
</row>
<row>
<column name="Notes">Starboardside winch forward on focsule (ref
motor No.1)
Starter cover plate removed-bolts replaced with stainless steel ones due
severe weathering of original
mild steel bolts-greased accordingly.
Starter inspected and find in a clean dry condition with no signs of any
cabling overheating and physical
insulation in good order. No signs of any chaffing of the 3 phase cabling.
Wiring throughout the starter is secure.
The starter component mounting plate was found secure and no mounting
fastening fixture had
vibrated loose. The 440V control voltage transformer was found securely
mounted to the mounting
plate, this component having been found loose in this class of ship in the
past.
All electrical components found in good condition on mounting plate and
secure.
The main contactor Telemecanique LC1 F185, the stationary and moving
contacts were removed and
dressed up as found dirty and well pitted, arc shutes cleaned but in good
condition.
These contacts have had 3 years usage and would advise changeout after this
dressing up-order has
been given to Cheng for replacements.
Insulation reading wrt earth starter to motor 300 meg ohms.
The motor terminal box was not removed to check the motor tails at this
time, and within the
terminal box, as experience previously has found that the mounting bolts to
be well seized and are
highly liable to snap in the course of removing them, they are mild
steel/painted.
The Cheng was/has been advised of this fact.
The various lamps,switches etc mounted on the control plate and exposed to
weather are operative
but are weathering and will eventually leak water internally in the future,
due to both rusting and
chemical reaction of the plate holes required to mount the components.
As weather is entering the actual components are suffering from
weathering/chemical reaction and will
also require replacing in the near future, the clue shortly will be when
personnel advise that the
pushbutton switches are prone to sticking, as this will be a direct
consequence of the weathering
process.
</column>
<column name="MaintLogID1">BRMR35024884</column>
</row>
<row>
<column name="Notes">Starboardside winch forward on focsule (ref
motor No.2)
Starter cover plate removed-bolts replaced with stainless steel ones due
severe weathering of original
mild steel bolts-greased accordingly.
Bottom of the starter at floor level was found covered in hydraulic oil-
this mopped out.
Cheng advised and sited, thought possible crack at outbd aft corner-to be
kept an eye on.
Starter inspected and find in a clean dry condition with no signs of any
cabling overheating and physical
insulation in good order. No signs of any chaffing of the 3 phase cabling.
Wiring throughout the starter is secure.
The starter component mounting plate was found secure and no mounting
fastening fixture had
vibrated loose. The 440V control voltage transformer was found securely
mounted to the mounting
plate, this component having been found loose in this class of ship in the
past.
All electrical components found in good condition on mounting plate and
secure.
The main contactor Telemecanique LC1 F185, the stationary and moving
contacts were removed and
dressed up as found dirty and well pitted, arc shutes cleaned but in good
condition.
These contacts have had 3 years usage and would advise changeout after this
dressing up-order has
been given to Cheng for replacements.
Insulation reading wrt earth starter to motor 300 meg ohms.
The motor terminal box was not removed to check the motor tails at this
time, and within the
terminal box, as experience previously has found that the mounting bolts to
be well seized and are
highly liable to snap in the course of removing them, they are mild
steel/painted.
The Cheng was/has been advised of this fact.
The various lamps,switches etc mounted on the control plate and exposed to
weather are operative
but are weathering and will eventually leak water internally in the future,
due to both rusting and
chemical reaction of the plate holes required to mount the components.
As weather is entering the actual components are suffering from
weathering/chemical reaction and will
also require replacing in the near future, the clue shortly will be when
personnel advise that the
pushbutton switches are prone to sticking, as this will be a direct
consequence of the weathering
process.
The indicator lamp showing power available ref motor No.2 found with cover
missing and filament bulb
open to weather/elements.
Therefore removed this indicator lamp, wiring taped up within starter and
22mm hole sealed with
rubber strip siliconed inside and out on the component mounting cover
plate, to prevent weather ingress.
</column>
<column name="MaintLogID1">BRMR35024885</column>
</row>
<row>
<column name="Notes">VHF DSCs tested against each other and
satisfactory.
MF/HF DSC tested but recd no acknowledgement back
Entries made into GMDSS Log book accordingly</column>
<column name="MaintLogID1">BRMR35024886</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35024887</column>
</row>
<row>
<column name="Notes">Rudder angle indicater corresponds ok to
actual rudder angle.
Bridge ceiling indicator reads ok up to 30 degree.
Linkages checked secure and in good order.</column>
<column name="MaintLogID1">BRMR35024888</column>
</row>
<row>
<column name="Notes">work completed as per p.m</column>
<column name="MaintLogID1">BRMR35024889</column>
</row>
<row>
<column name="Notes">Work completed as per pm
Filter cleaned and inspected
Seal on cover inspected
When reassembled, unit vented and checked for leaks.
All found satisfactory.
</column>
<column name="MaintLogID1">BRMR35024890</column>
</row>
<row>
<column name="Notes">Completed and entered in
QC&MEASURE</column>
<column name="MaintLogID1">BRMR35024891</column>
</row>
<row>
<column name="Notes">Landed at Singapore 10/04/07</column>
<column name="MaintLogID1">BRMR35024892</column>
</row>
<row>
<column name="Notes">This is a repeat PM. Completed and landed at
Singapore 10/04/07</column>
<column name="MaintLogID1">BRMR35024893</column>
</row>
<row>
<column name="Notes">Tank inspected in January. Several cracks
found and were repaired
2. Crack between Port distilled and Port Domestic tank. approx 22 inches
Crack cut out and plate insert welded.
1) High Cooling water temperature. This alarm can be tested with the
engine stopped. Remove the temperature probe and
place it in the hotbox. Using a multimeter, check the
temperature at which the contacts close, alarm should sound at
103 oC. With the probe now tested, place a link between the
crimped conections that connect to the probe and check
alarm sounds on pannel.
2) Low L.O. pressure. With the engine running close the valve that
isolates the L.O. pressure sensor.
Bleed off the L.O. pressure by slackening back on one of the
couplings for the line to the L.O. pressure gauge.
Observe the falling pressure and note when the alarm and
indicator light are activated.
Should activate at 170 Kpa.
3) Fuel Oil Leakage. With the engine stopped, add fuel to the
leakage collection chamber via the vent line.
4) Battery Charger Failure. Switch off the battery charger. This
will also give and alarm on the IAS.
5) F.O. Service Tank Low level alarm. Isolate the fuel gauge
indicator column and drain the column down.
Once alarm ahs activated close the drain and open up the
column isolation valves.
6) Engine Overspeed Alarm. With the engine running put a link in
between terminals 15 and 18 on the OSC relay.
The charge air shut off flap will close and the engine will
trip. To reset this alarm, move the reset lever on the charge air
shut off flap to the open position then press the reset
button on the panel. The alarm should now be reset and the air
shut off flap will remain in the open position.
flap will remain in the open position.
6) Hydraulic return filter reading zero hence not changed out at this.time
</column>
<column name="MaintLogID1">BRMR35024915</column>
</row>
<row>
<column name="Notes">Completed as part of 24 monthly
Oil Changed</column>
<column name="MaintLogID1">BRMR35024916</column>
</row>
<row>
<column name="Notes">Completed as per PM. Engine failed to start
from emergency power. This has been looked into by the ETO.
See ETO unscheduled work order for more details.
Didn't smell too bad and clear water found at top of clarification
chamber.
NOTE:
As the Vacuumarrator has a cooling line steming from the first stage
aeration chamber, the
vacuum toilet system was shut down for a period whilst this tank was
cleaned.</column>
<column name="MaintLogID1">BRMR35024922</column>
</row>
<row>
<column name="Notes">Completed, No.1 now lead compressor.</column>
<column name="MaintLogID1">BRMR35024923</column>
</row>
<row>
<column name="Notes">Completed, No.1 now lead compressor.</column>
<column name="MaintLogID1">BRMR35024924</column>
</row>
<row>
<column name="Notes">completed</column>
<column name="MaintLogID1">BRMR35024925</column>
</row>
<row>
<column name="Notes">All fire flaps operated without
problem.</column>
<column name="MaintLogID1">BRMR35024926</column>
</row>
<row>
<column name="Notes">completed as per PM, No.1 NIU</column>
<column name="MaintLogID1">BRMR35024927</column>
</row>
<row>
<column name="Notes">completed as per PM, No.1 NIU</column>
<column name="MaintLogID1">BRMR35024928</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024929</column>
</row>
<row>
<column name="Notes">Tested as per PM - all fully
operational.</column>
<column name="MaintLogID1">BRMR35024930</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024931</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35024932</column>
</row>
<row>
<column name="Notes">Ran on test - fully operational</column>
<column name="MaintLogID1">BRMR35024933</column>
</row>
<row>
<column name="Notes">Completed as per PM - fully
operational</column>
<column name="MaintLogID1">BRMR35024934</column>
</row>
<row>
<column name="Notes">Completed as per PM - fully
operational</column>
<column name="MaintLogID1">BRMR35024935</column>
</row>
<row>
<column name="Notes">Burner clean and in good condition.
spark arrester removed and found to be clean.
</column>
<column name="MaintLogID1">BRMR35024944</column>
</row>
<row>
<column name="Notes">Gears inspected no problems found,
Oil changed approx 2.5 litres GRXP-220 used
Brake securing nuts tight
New cover joint made and fitted.
</column>
<column name="MaintLogID1">BRMR35024945</column>
</row>
<row>
<column name="Notes">Level about 3/4 full.
Awaiting dolomite which is in Trinidad.</column>
<column name="MaintLogID1">BRMR35024946</column>
</row>
<row>
<column name="Notes">Run for 24 hours</column>
<column name="MaintLogID1">BRMR35024947</column>
</row>
<row>
<column name="Notes">New antenna received and fitted</column>
<column name="MaintLogID1">BRMR35024948</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 90A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-6N(125) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 433 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024949</column>
</row>
<row>
<column name="Notes">Appears to be in generally good condition. No
sign of deformation of stringers or shell plating.
In generally good condition. Some localised break down in one or
two spots now appearing in 'ullage' space at top. One spot noted
of rust coming through coating on tank bottom. A few small areas of coating
breakdown on edge of stringers. In good condition. All securely fitting.
All in good condition. Sounding pipes and Elephants foot clear.
Upto 1 cm deep in mid to upper levels, thin areas towards bottom.
</column>
<column name="MaintLogID1">BRMR35024950</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 120A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-7N(150) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 448 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024951</column>
</row>
<row>
<column name="Notes">Appears to be in generally good condition. No
sign of deformation of stringers or shell plating.
In generally good condition. Some localised break down in one or
two spots now appearing in 'ullage' space at top. One spot noted
of rust coming through coating on tank bottom. A few small areas of coating
breakdown on edge of stringers. In good condition. All securely fitting.
Little or no wastage All in good condition. Sounding pipes and
Elephants foot clear. Upto 2 cm deep in mid to upper levels, thin areas
towards bottom. </column>
<column name="MaintLogID1">BRMR35024952</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 75A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-6N(125) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Space heater impedance 1622 ohms and 220V feed satisfactory.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024953</column>
</row>
<row>
<column name="Notes">Appears to be in generally good condition. No
sign of deformation of stringers or shell plating.
In generally good condition. Some localised break down in one or
two spots now appearing in 'ullage' space at top. One spot noted
of rust coming through coating on tank bottom. A few small areas of coating
breakdown on edge of stringers. In good condition. All securely fitting.
Little or no wastage All in good condition. Sounding pipes and
Elephants foot clear. Upto 2 cm deep in mid to upper levels, thin areas
towards bottom. </column>
<column name="MaintLogID1">BRMR35024954</column>
</row>
<row>
<column name="Notes">Appears to be in generally good condition. No
sign of deformation of stringers or shell plating.
In generally good condition. Some localised break down in one or
two spots now appearing in 'ullage' space at top. One spot noted
of rust coming through coating on tank bottom. A few small areas of coating
breakdown on edge of stringers. In good condition. All securely fitting.
Little or no wastage All in good condition. Sounding pipes and
Elephants foot clear. Upto 1 cm deep in mid to upper levels, thin areas
towards bottom. 0</column>
<column name="MaintLogID1">BRMR35024955</column>
</row>
<row>
<column name="Notes">Equipment in good condition and operational.
Overhead readout on bridge satisfactory and actual speed/direction unit up
main mast is in good
condition. This was inspected on the recent DSAS batt changeout as working
immediately adjacent
to the speed cups and vane.
There are no known or reported defects with this equipment at this
time.</column>
<column name="MaintLogID1">BRMR35024956</column>
</row>
<row>
<column name="Notes">Starter Opened up and inspected.
Find in a clean operable condition with no signs of any overheating of any
cable or component.
Wiring is secure throughout the starter and at the rear auxilliary terminal
strips wiring.
The 3phase wiring is secure throughout and at the outgoing motor terminal
strip at the rear of the starter.
Relay wiring secure and relays securely mounted.
Overload is set at 1,22A and consistenent with the red spot marking, and
indicator on front panel mounted meter.
The main contactor SC-03(11) contacts fixed/moving and arc shutes all in
good condition.
The fixed contacts checked for tightness and found satisfactory.
Fuses/fuse holders are in good condition and fitted with the correct rated
fuses.
Motor Terminal box cover removed for inspection, retaining bolts greased.
Motor wiring tails in good condition and secure, incoming phase wiring in
good condition and secure, no sign of any overheating.
Motor Earth wiring in place and secure.
Cabling earth wires in place and secure.
Insulation starter to motor wrt earth is >999 Meg Ohms
Indicator Lamps on starter box operational (Lamped up as Reqd)
</column>
<column name="MaintLogID1">BRMR35024957</column>
</row>
<row>
<column name="Notes">Wire not greased as done recently.</column>
<column name="MaintLogID1">BRMR35024958</column>
</row>
<row>
<column name="Notes">Wire not greased as done recently.</column>
<column name="MaintLogID1">BRMR35024959</column>
</row>
<row>
<column name="Notes">Meat room, Dairy room, Fish Room alarms tested
every saturday and have been found satisfactory.
All sound within the CCR and register ok on the alarm printout.
The red identifier indicater within the room is regularly lamped up as
required and all 3 units/lamps are
operational/illuminated.
The 2 hospital call alarms are also regularly tested on saturdays and sound
within CCR and register ok
on the alarm printer.
During course of trip find that the S alarm usually occurs when there is a
lot of ship vibration, but always clears when unit is
rebooted.</column>
<column name="MaintLogID1">BRMR35024974</column>
</row>
<row>
<column name="Notes">Unit tested, works satisfactory.</column>
<column name="MaintLogID1">BRMR35024975</column>
</row>
<row>
<column name="Notes">The Rudder Bonding cable is secure.
Shaft earthing device slip ring and brush gear cleaned at Damieta.
Brush wear is satisfactory.</column>
<column name="MaintLogID1">BRMR35024976</column>
</row>
<row>
<column name="Notes">The Rudder Bonding cable is secure.
Shaft earthing device slip ring and brush gear cleaned at Damieta.
Brush wear is satisfactory.</column>
<column name="MaintLogID1">BRMR35024977</column>
</row>
<row>
<column name="Notes">The radar is working satisfactorily.
The computer fan filters are clean.
The rear fans air filters are clean.
The scanner holding down bolts are secure and none missing.
When the spare antenna motor is received it is recommended to fit it
immediately on receipt
Spare Antenna motor has been ordered & await delivery to vsl, for the:-
Kelvin Hughes
Turning Mechanism 10KW
Code No. CAE-A30-6
Batch ID AAAA Serial Number: MG 3060133
W0P701194 059</column>
<column name="MaintLogID1">BRMR35024978</column>
</row>
<row>
<column name="Notes">Gyro operation satisfactory and no known or
reported defects at this time.
Gyro current checked (259mA @ 47degC) and within spec.</column>
<column name="MaintLogID1">BRMR35024979</column>
</row>
<row>
<column name="Notes">Equipment operation is fine.
There are no reported defects with this item of equipment, however copy
here again of what can happen
to it on occasions:-
Equipment operation is satisfactory.
Have observed on two occasions equipment has "freezed up" none of
front mounted controls will work,
only remedy has been to turn off unit from its 220V input supply, leave
for few seconds and switch on
again, Then operation is ok.</column>
<column name="MaintLogID1">BRMR35024980</column>
</row>
<row>
<column name="Notes">Gyro operation satisfactory and no known or
reported defects at this time.
Gyro current checked (267mA @ 47degC) and within spec.</column>
<column name="MaintLogID1">BRMR35024981</column>
</row>
<row>
<column name="Notes">Operation of air whistle is satisfactory,
visually inspecting unit on monkey island all would appear to
be in good order.
Unit working satisfactory as evidenced at noon when utilised.</column>
<column name="MaintLogID1">BRMR35024982</column>
</row>
<row>
<column name="Notes">GMDSS Equipment general inspection carried out
ok.</column>
<column name="MaintLogID1">BRMR35024983</column>
</row>
<row>
<column name="Notes">Equipment operational as evidenced at noon
when utilised.
Recent work on lights up foremast, inspected unit and in good condition.
Control panel on bridge in good condition.
Heaters on and regular check kept that they remain on has insured to date
no low insulation readings
from the foremast mounted motor.</column>
<column name="MaintLogID1">BRMR35024984</column>
</row>
<row>
<column name="Notes">Centralised clock system is working
satisfactory.
Control unit on bridge is in good condition and the wiring is secure.
Clocks around the vessel are in good condition, and as evidenced on this
voyage east from damietta to
Korea, no defects noted in advancing the clocks.</column>
<column name="MaintLogID1">BRMR35024985</column>
</row>
<row>
<column name="Notes">Battery charger isolated 020830hrs
Battery charger reconnected 021630hrs
Batteries fully recharged.
These details also placed in GMDSS LOGBOOK for this test.
26.3 25.3
24.5 Lcd mon.
0 5.1
5.3 Current
A & B =42Vac
Blank
C & D = 42Vac to Engine Heater
Blank
Blank
E linked to H (-ve No.1 Batt)
F goes to ground pin of battery seperator
G (+ve) and H (-ve) to No.1 Battery
I (+ve) and I (-ve/blue mark) to No.2 Battery
A B X C D X X E F G H I I
wiring looking left to right on actual charger
Wire an old battery from fire alarm system and connect up as normal,
check charger and find:-
1. Battery V prior connection 13,5V
2. Connected to charger, Voltage at batteries is ZERO, charger indicates
green. Therefore massive load on No.1 battery.
3. Find by disconnecting E & F wiring above, normal charging operation
ok.
Therefore the Battery Seperator causing overload.
2 new 12V 55Ah batteries being ordered by cheng and request for details on
battery seperator/wiring diagram from manufacturer.
The rescue boat engine can be started at present utilizing the emergency
switch posn only-tested with 4/Eng satisfactory.
Whilst above work carried out observed damaged wiring on bilge level switch
this repaired (brown wiring was O/C), also rerouted cabling instead of
lying in bilge.
</column>
<column name="MaintLogID1">BRMR35024990</column>
</row>
<row>
<column name="Notes">TRON 40S EPIRB
Serial No. 131AH21518
Battery Expiry Date: Jan 2012
Hydrostatic Release Expiry: Jan 2009
This unit recently exchanged in January, the old unit sent back for service
less batteries.
Unit tested satisfactory and in good condition.
Test details in GMDSS Log Book
No.1 FG Burner Pipe One crack found approx 8 meters from Gas hood Bulkhead
(outboard side)
Crack cut out and welded. Doubler plate welded over the effected area. Pipe
line pressure tested.
Metaflex gaskets renewed. New support arrangement with 5 fins fitted around
pipe.
No.3 FG Burner Pipe One Crack found apprx 8 meters from gas hood bulkhead.
(Inboard side)
Crack cut out and plate insert welded. Pipe pressure tested. Metaflex
gaskets renewed.
New support arrangement with 5 fins fitted around pipe.
Port Boiler
---------------
No.1 FG Burner One crack found approx 8" from gas hood bulkhead.
Crack cut out and plate insert welded.
Pipe pressure tested. Metaflex gaskets renewed.
No.2 FG Burner Pipe pressure testes and found tight. Metaflex gaskets
renewed.
No.3 FG Burner Pipe pressure testes and found tight. Metaflex gaskets
renewed.
All work completed together with SES marine riding squad between 11/03/07
and 24/03/07.</column>
<column name="MaintLogID1">BRMR35025010</column>
</row>
<row>
<column name="Notes">Password is 33 as per the manual.
Flange faces are badly cut and will require machining at the next
docking</column>
<column name="MaintLogID1">BRMR35025013</column>
</row>
<row>
<column name="Notes">Anodes replaced.
All wiring checked and okay.
Suggest replcing the cables due to the existing ones being painted.
New cables are on order.</column>
<column name="MaintLogID1">BRMR35025014</column>
</row>
<row>
<column name="Notes">Both operated ok</column>
<column name="MaintLogID1">BRMR35025015</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025016</column>
</row>
<row>
<column name="Notes">Unit in operation
Valves operating ok</column>
<column name="MaintLogID1">BRMR35025017</column>
</row>
<row>
<column name="Notes">Both operated ok</column>
<column name="MaintLogID1">BRMR35025018</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025019</column>
</row>
<row>
<column name="Notes">Both operated ok</column>
<column name="MaintLogID1">BRMR35025020</column>
</row>
<row>
<column name="Notes">Not Done This Week.</column>
<column name="MaintLogID1">BRMR35025021</column>
</row>
<row>
<column name="Notes">Calibrated all satisfactory</column>
<column name="MaintLogID1">BRMR35025022</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025023</column>
</row>
<row>
<column name="Notes">Unit not is use due to air rgulator missing,
not calibrated</column>
<column name="MaintLogID1">BRMR35025024</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025025</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025026</column>
</row>
<row>
<column name="Notes">Lube oil pump ok
heaters functioning correctly</column>
<column name="MaintLogID1">BRMR35025027</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025028</column>
</row>
<row>
<column name="Notes">Unit in use
lube oil pump on standby
heater functioning correctly</column>
<column name="MaintLogID1">BRMR35025029</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025030</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025031</column>
</row>
<row>
<column name="Notes">Lube oil pump ok
heaters functioning correctly</column>
<column name="MaintLogID1">BRMR35025032</column>
</row>
<row>
<column name="Notes">Lube oil pump ok
heaters functioning correctly</column>
<column name="MaintLogID1">BRMR35025033</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025034</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025035</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025036</column>
</row>
<row>
<column name="Notes">All valves operated no problems found</column>
<column name="MaintLogID1">BRMR35025037</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025038</column>
</row>
<row>
<column name="Notes">Completed</column>
<column name="MaintLogID1">BRMR35025039</column>
</row>
<row>
<column name="Notes">All operated all OK</column>
<column name="MaintLogID1">BRMR35025040</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35025041</column>
</row>
<row>
<column name="Notes">All operate freely</column>
<column name="MaintLogID1">BRMR35025042</column>
</row>
<row>
<column name="Notes">Tested all operational</column>
<column name="MaintLogID1">BRMR35025043</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35025044</column>
</row>
<row>
<column name="Notes">Various Cracks found inside Stbd FW tank.
Investigated
Disconnected all wiring feeding to/from zone 11 and within motor room
all lines 250 megs. with wiring and detectors 3 pce disconnected and 4
fuses
removed concerning zone 11 loop 24V DC, earth still appearing.
Therefore regardless of the displayed legend the earth has nothing to do
with Zone 11.
The actuating spindle for the main breaker find very difficult to locate
when closing door.
</column>
<column name="MaintLogID1">BRMR35025057</column>
</row>
<row>
<column name="Notes">Funnel Floodlights
These lights have been causing earth alarms due to water ingress.
The cause of the water ingress has been found to be cracked stainless steel
casings around area of the mounting bolts.
Temporary fix - the hairline cracks in the steel have been filled with
araldite.
The gasket seals are also suspect.
These lights 220V 500W Halogen are to be replaced, order given to cheng
for replacements.
Fit new lights when received and then idea is to utilise the
original/defective casing ones in the engineroom around the FD fan area.
</column>
<column name="MaintLogID1">BRMR35025058</column>
</row>
<row>
<column name="Notes">6th April 2007
Received a new floppy disc drive last call Singapore.
Fitted this new floppy disc drive into ROS1(Conning Computer)
and all satisfactory
</column>
<column name="MaintLogID1">BRMR35025059</column>
</row>
<row>
<column name="Notes">Light Signal Columns
Various units in workshop left by previous eto with notes as to condition,
due experience of units decided to double check the HJ-107-1 types. Light
Signal Columns
The original HJ-107 in ER workshop found with fuses pulled and not working.
Inserted fuses and still not working find potentiometer turned to zero. Set
this unit for a comfortable audio level and ok.
Removed and wired in one pce HJ-107-1 unit, set potentiometer and found
working. Removed this unit and took up to Emg Gen room.
Unwired the not working HJ-107-1 unit and installed the tested HJ-107-1
unit, again not working.
Tested relays and find one piece defective-replaced.
Emg Gen alarm light signal column now working
Original fitted HJ-107-1 unit from emg gen room- then wired into ER
Workshop and find working ok.
O O O O O O O O O
O O O
< X >
Make sure the plug is fitted well into the socket (440V) as otherwise this
effects heating as observed during testing
Salamander Grill left only with left hand side bank of elements working,
Right hand side bank, thermostat wound down to zero and taped up and
catering dept told not to use
</column>
<column name="MaintLogID1">BRMR35025061</column>
</row>
<row>
<column name="Notes">Explosion Proof lights
Location: Chemical Locker Starboard side upper deck aft.
During the course of lamping up find this fitting with broken lampholders.
No spare lampholders onboard.
Order given to Cheng and on receipt this light should have its lampholders
replaced.
</column>
<column name="MaintLogID1">BRMR35025062</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
</column>
<column name="MaintLogID1">BRMR35025063</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.Sintered ceramic probe filter changed.
One left, more requested.
</column>
<column name="MaintLogID1">BRMR35025064</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025065</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025066</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025067</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025068</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025069</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025070</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025071</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025072</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025073</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025074</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work
Order.</column>
<column name="MaintLogID1">BRMR35025075</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
Additionally this unit suffered failure of disch pipe for No;-2 sealed
compressor.
Oil & Gas was lost. Condr recovered after isolation, pipe repaired and
unit reassembled,
re-oiled & re-gassed. Put back in service ok.</column>
<column name="MaintLogID1">BRMR35025076</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
All checks out OK.</column>
<column name="MaintLogID1">BRMR35025077</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
All checks out OK.</column>
<column name="MaintLogID1">BRMR35025078</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
All checks out OK. 0.7Mpa on Gauge.</column>
<column name="MaintLogID1">BRMR35025079</column>
</row>
<row>
<column name="Notes">Completed satisfactorily as per Work Order.
All checks out OK. 0.7Mpa on Gauge.</column>
<column name="MaintLogID1">BRMR35025080</column>
</row>
<row>
<column name="Notes">Completed as per work order. All in good
order.
</column>
<column name="MaintLogID1">BRMR35025081</column>
</row>
<row>
<column name="Notes">Duplicate PM history under work order
MER/07/01068
Component No. 8.0328.01
Vacumator</column>
<column name="MaintLogID1">BRMR35025082</column>
</row>
<row>
<column name="Notes">Pump anodes inspected, top anodes found to be
100% wasted. Bottom anode approx 30%
Both anodes replaced, due to work required to check bottom anode</column>
<column name="MaintLogID1">BRMR35025083</column>
</row>
<row>
<column name="Notes">Anodes found to be approx 50 % wasted, not
replaced at this time</column>
<column name="MaintLogID1">BRMR35025084</column>
</row>
<row>
<column name="Notes">Not carried out at this time
Awaiting arrival of service kit</column>
<column name="MaintLogID1">BRMR35025085</column>
</row>
<row>
<column name="Notes">Fire pump started using spring start, all
satisfactory
Still awaiting new batteries</column>
<column name="MaintLogID1">BRMR35025086</column>
</row>
<row>
<column name="Notes">All sets inspected and cleaned, all bottle
pressures checked
All satisfactory</column>
<column name="MaintLogID1">BRMR35025087</column>
</row>
<row>
<column name="Notes">Diesel Genny ran on load test 882kw
Log taken, all readings satisfactory</column>
<column name="MaintLogID1">BRMR35025088</column>
</row>
<row>
<column name="Notes">Stretchers checked and in good condition.
Paraguard had been used recently in enslosed space rescue drills and
required cleaning. Otherwise no further action required.
All accessories present and in good condition for the Paraguard, except of
course the shoulder harnesses which we dont have onboard.</column>
<column name="MaintLogID1">BRMR35025089</column>
</row>
<row>
<column name="Notes">Emerg genny ran off load
Electric start
All satisfactory</column>
<column name="MaintLogID1">BRMR35025090</column>
</row>
<row>
<column name="Notes">Ran in parallel with duty feed pump, all
satisfactory</column>
<column name="MaintLogID1">BRMR35025091</column>
</row>
<row>
<column name="Notes">Duty feed pump</column>
<column name="MaintLogID1">BRMR35025092</column>
</row>
<row>
<column name="Notes">VHF DSCs tested against each other and
satisfactory.
MF/HF DSC tested but recd no acknowledgement back
Entries made into GMDSS Log book accordingly</column>
<column name="MaintLogID1">BRMR35025093</column>
</row>
<row>
<column name="Notes">All manual valves worked through
range</column>
<column name="MaintLogID1">BRMR35025094</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35025095</column>
</row>
<row>
<column name="Notes">Priming pump turned by hand
Actuator proved free
Water tank level checked</column>
<column name="MaintLogID1">BRMR35025096</column>
</row>
<row>
<column name="Notes">TRON 40S EPIRB
Serial No. 131AH21518
Battery Expiry Date: Jan 2012
Hydrostatic Release Expiry: Jan 2009
This unit recently exchanged in January, the old unit sent back for service
less batteries.
Unit tested satisfactory and in good condition.
Test details in GMDSS Log Book
Nyborg
Type: C240R 987712004
Serial No. 0111/0004340 QC 14505895
440Vac 3 phase 60hz
Max 400W 10A
Max loading 8kG
Initially found machine not working then got working, however it is erratic
in operation and not consistent.
1. Sometimes unable to open the lid
2. Sometimes not able to start
3. When working and pressing stop the machine stops , but operation can be
erratic
Previously had trouble with solenoid, in that mounting screws apparently
shorting voltage, and also mechanical lock when lid closed.
Removed the printed cct board MP (CPU-/Relay Print)and found relay RL2
Omron G2L-1-V 24VDC coil contacts 250VAC 8A LR89731, faulty in area of
relay contacts in that with no power to coil, respective contacts open
circuit,no spares.
Tried using a externally mounted 24V relay with wires to simulate
but this did not cure the problem.
Edge conns appeared slack fir, built up with solder but this also did not
cure.
Very little detail on machine and cheng trying to obtain more info and
parts list, as no spares onboard for the machine.
Machine taken out of service as unreliable in present condition.
Until new batteries sourced boat running with only 1 battery and the
circuit from charger disconnected at
the charger and the ground connection disconnected on battery seperator,
thereby allowing charging and
engine starting etc satisfactorily.
Singapore 10th April received 2 new Exide 12V 55AH 80D26R batteries.
These installed in the rescue boat, battery seperator left disconnected and
Cheng advised.
</column>
<column name="MaintLogID1">BRMR35025112</column>
</row>
<row>
<column name="Notes">New contactor fitted along with new cable
tails.
Wiring found with no ID to disconnection and tags missing or different to
unit remaining in use.
Drawings have limited cable IDs and wiring different on unit remaining in
use.
Circuit ringed and labelled and wired accordingly-2 wires location not
fully identified but wired as thought should
be. circuit tested and found ok with normal operation. overload test/ok
</column>
<column name="MaintLogID1">BRMR35025123</column>
</row>
<row>
<column name="Notes">Work completed as per PM.
Everything found to be satisfactory
Reassembled and tested.</column>
<column name="MaintLogID1">BRMR35025124</column>
</row>
<row>
<column name="Notes">Completed as per pm.
Everthing found to be satisfactory.
Reassembled ant tested</column>
<column name="MaintLogID1">BRMR35025125</column>
</row>
<row>
<column name="Notes">Starter opened up and inspected.
Circuit breaker is defective and locked mechanically in the on position-but
isolated at the MSB.
This circuit breaker is on order and to be replaced upon receipt on vessel.
The main contactor Telemecanique LC1 400 stationary/moving contacts
inspected and found in good
condition. Arc shutes inspected and found in good condition.
Relays K6 thru to K14 secure.
Terminal strip wiring found secure.
No signs of any cable overheating within cabinet.
Overload 298A
Motor terminal box opened and wiring within in good condition and
insulation intact.
Motor 300 meg ohms wrt earth.
Space heater operational.
externally pressure switch/Solenoid wiring is in good condition and
secure.</column>
<column name="MaintLogID1">BRMR35025126</column>
</row>
<row>
<column name="Notes">2/E advises this job effected recently by
himself.</column>
<column name="MaintLogID1">BRMR35025127</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory.
No known or reported defects at this time.</column>
<column name="MaintLogID1">BRMR35025128</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory-unit now
fitted with 23 inch TFT display.
Computer filters clean.</column>
<column name="MaintLogID1">BRMR35025129</column>
</row>
<row>
<column name="Notes">Equipment operation satisfactory.
Externally equipment in good condition visually.</column>
<column name="MaintLogID1">BRMR35025130</column>
</row>
<row>
<column name="Notes">Motorola Radios found in use onboard in March
2007
Serial Numbers as follows:-
402TCN3448
402TCN3537
402TCQ1178
402TCQ1194
402TCQ1195
402TCQ1201
402TCQ1211
402TCQ4778
402TCQ4799
402TDE1998
402TCQ4802
402TCN2640
402TDE1084
402TDE1989
402TCQ1216
402TDE2005
402TDE2008
402TDE2014
402TDE2020
402TDE2027
Allyway escape lights and cargo switchboard room 1 & 2 exit light were
turned off for 30 min, to check the batteries. Only two batteries
didn't pass the test and need to be changed:
- Cargo switchboard room1 exit light on the top of the doors between Cargo
Switchboard Room's
- Cargo switchboard room exit light in the top of the doors on stbd side.
Machinery spaces:
All emergency lights in the all engine room spaces ( all deck's,
emergancy gen room, IG room etc.) were turned off for 30 min. All batteries
passed the test.
</column>
<column name="MaintLogID1">BRMR35025145</column>
</row>
<row>
<column name="Notes">Completed as per PM, all fully
operational.</column>
<column name="MaintLogID1">BRMR35025146</column>
</row>
<row>
<column name="Notes">Completed, No. 2 now lead M/C.</column>
<column name="MaintLogID1">BRMR35025147</column>
</row>
<row>
<column name="Notes">Completed, No. 2 now lead M/C.</column>
<column name="MaintLogID1">BRMR35025148</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35025149</column>
</row>
<row>
<column name="Notes">Completed, all fully operational.</column>
<column name="MaintLogID1">BRMR35025150</column>
</row>
<row>
<column name="Notes">Completed, no.2 now in use.</column>
<column name="MaintLogID1">BRMR35025151</column>
</row>
<row>
<column name="Notes">Completed, no.2 now in use.</column>
<column name="MaintLogID1">BRMR35025152</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35025153</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35025154</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 1
2 3
3 2</column>
<column name="MaintLogID1">BRMR35025155</column>
</row>
<row>
<column name="Notes">Completed as per PM, all fully
satisfactory</column>
<column name="MaintLogID1">BRMR35025156</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35025157</column>
</row>
<row>
<column name="Notes">Fwd cooler online whilst aft cooler was
backflushed. Fwd cooler backflushed after use.</column>
<column name="MaintLogID1">BRMR35025158</column>
</row>
<row>
<column name="Notes">Aft cooler backflushed, no
observations.</column>
<column name="MaintLogID1">BRMR35025159</column>
</row>
<row>
<column name="Notes">Oil changed out as the last record of an oil
change was some time ago. The oil removed was found
discoloured and dirty. Oil will be changed again in one months time to
allow for flushing of the sump.
</column>
<column name="MaintLogID1">BRMR35025195</column>
</row>
<row>
<column name="Notes">All lifejackets in very good condition with
whistles, sprayhoods attached and lights in date
No damaged safety helmets. Some superficial marks but one would expect
this due to daily wear.</column>
<column name="MaintLogID1">BRMR35025196</column>
</row>
<row>
<column name="Notes">Immersion suits in good condition and stowed
as per plan.
Practically as new.</column>
<column name="MaintLogID1">BRMR35025197</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025198</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025199</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025200</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025201</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025202</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025203</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025204</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025205</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025206</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025207</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025208</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025209</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35025210</column>
</row>
<row>
<column name="Notes">Tested on local electric start.
Fuel tk lvl 0.82 mcb</column>
<column name="MaintLogID1">BRMR35025211</column>
</row>
<row>
<column name="Notes">All sets and bottles checked.
Pressure within limits.
Sets in good condition.</column>
<column name="MaintLogID1">BRMR35025212</column>
</row>
<row>
<column name="Notes">D/Alt run whilst runing up 2nd T/Alt for
Singapore stand by.</column>
<column name="MaintLogID1">BRMR35025213</column>
</row>
<row>
<column name="Notes">Unit tested on Local battery start.
All in good order.</column>
<column name="MaintLogID1">BRMR35025214</column>
</row>
<row>
<column name="Notes">Stby pump run on test.
All in good order.</column>
<column name="MaintLogID1">BRMR35025215</column>
</row>
<row>
<column name="Notes">Stby feed pump run on test.
All in good order.</column>
<column name="MaintLogID1">BRMR35025216</column>
</row>
<row>
<column name="Notes">All valves free to operate.
Spindles greased.</column>
<column name="MaintLogID1">BRMR35025217</column>
</row>
<row>
<column name="Notes">Prining pumps free to move.
In good order.</column>
<column name="MaintLogID1">BRMR35025218</column>
</row>
<row>
<column name="Notes">Priming pumps free to move.
In good order.</column>
<column name="MaintLogID1">BRMR35025219</column>
</row>
<row>
<column name="Notes">Priming pumps free to move.
In good order.</column>
<column name="MaintLogID1">BRMR35025220</column>
</row>
<row>
<column name="Notes">Priming pumps free to move.
In good order.</column>
<column name="MaintLogID1">BRMR35025221</column>
</row>
<row>
<column name="Notes">Priming pumps free to move.
In good order.</column>
<column name="MaintLogID1">BRMR35025222</column>
</row>
<row>
<column name="Notes">Battery check on float charge.
Batterie are clean of dust and the terminals are greased.
Cell Voltages:-
1: 2.28V
2: 2.27V
3: 2.27V
4: 2.28V
5: 2.27V
6: 2.27V
7: 2.29V
8: 2.28V
9: 2.34V
10: 2.34V
11: 2.28V
12: 2.27V
All: 27.39V</column>
<column name="MaintLogID1">BRMR35025223</column>
</row>
<row>
<column name="Notes">All OK. Out of date eyepads replaced at one
station.</column>
<column name="MaintLogID1">BRMR35025225</column>
</row>
<row>
<column name="Notes">Valve operated
All OK</column>
<column name="MaintLogID1">BRMR35025229</column>
</row>
<row>
<column name="Notes">Valve opearted
All ok</column>
<column name="MaintLogID1">BRMR35025230</column>
</row>
<row>
<column name="Notes">Valve operated
All OK</column>
<column name="MaintLogID1">BRMR35025231</column>
</row>
<row>
<column name="Notes">Valve Operated
All Ok</column>
<column name="MaintLogID1">BRMR35025232</column>
</row>
<row>
<column name="Notes">Calibrated ok</column>
<column name="MaintLogID1">BRMR35025233</column>
</row>
<row>
<column name="Notes">No 1 in use</column>
<column name="MaintLogID1">BRMR35025234</column>
</row>
<row>
<column name="Notes">Compressor turned by hand</column>
<column name="MaintLogID1">BRMR35025235</column>
</row>
<row>
<column name="Notes">Compressor turned by hand</column>
<column name="MaintLogID1">BRMR35025236</column>
</row>
<row>
<column name="Notes">Compressor turned by hand</column>
<column name="MaintLogID1">BRMR35025237</column>
</row>
<row>
<column name="Notes">Compressor turned by hand</column>
<column name="MaintLogID1">BRMR35025238</column>
</row>
<row>
<column name="Notes">All valves operated</column>
<column name="MaintLogID1">BRMR35025239</column>
</row>
<row>
<column name="Notes">Small amount of water found, system
drained</column>
<column name="MaintLogID1">BRMR35025240</column>
</row>
<row>
<column name="Notes">All alarms operated satisfactory</column>
<column name="MaintLogID1">BRMR35025241</column>
</row>
<row>
<column name="Notes">Operated ok</column>
<column name="MaintLogID1">BRMR35025242</column>
</row>
<row>
<column name="Notes">Ladder in good condition. Rope in good
condition. Steps all checked and found to be in satisfactory
condition.</column>
<column name="MaintLogID1">BRMR35025243</column>
</row>
<row>
<column name="Notes">SOLAS Fist Aid Kit replaced.
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35025273</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35025274</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 2
2 1
3 3</column>
<column name="MaintLogID1">BRMR35025275</column>
</row>
<row>
<column name="Notes">Tested as per PM, all fully
operational.</column>
<column name="MaintLogID1">BRMR35025276</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35025277</column>
</row>
<row>
<column name="Notes">All fully opertaional.</column>
<column name="MaintLogID1">BRMR35025278</column>
</row>
<row>
<column name="Notes">Burner changed out for spare.</column>
<column name="MaintLogID1">BRMR35025279</column>
</row>
<row>
<column name="Notes">All points lubricated with grease as detailed
in lubrication schedule.</column>
<column name="MaintLogID1">BRMR35025280</column>
</row>
<row>
<column name="Notes">All points lubricated with grease as detailed
in lubrication schedule.</column>
<column name="MaintLogID1">BRMR35025281</column>
</row>
<row>
<column name="Notes">All filters (Pre, after & control)
replaced with spares. Due to negligible backpressure on both towers
and limited spares, the purge mufflers were not chnaged on this occasion.
When more spares arrive
these are to be fitted.
All Satisfactory.</column>
<column name="MaintLogID1">BRMR35025283</column>
</row>
<row>
<column name="Notes">Small leakage observed from gland.
P/P inspected - Rotor and stator in good condition. Due to the gland being
overtightened this has begun
wearing the hollow shaft. This will be monitored to ensure pump capacity
doesn't drop off due to suction
through the gland. Gland re-packed.
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35025355</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35025356</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 2
3 1</column>
<column name="MaintLogID1">BRMR35025357</column>
</row>
<row>
<column name="Notes">Completed as per PM, all fully
operational.</column>
<column name="MaintLogID1">BRMR35025358</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35025359</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025360</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025361</column>
</row>
<row>
<column name="Notes">completed as per pm
clean photo resistor
clean out combustion chamber
clean all air inlets and cooling ports
run up and tested</column>
<column name="MaintLogID1">BRMR35025362</column>
</row>
<row>
<column name="Notes">completed as per pm
all covers and seals tight
all extinguishers shaken and inverted
all satisfactory</column>
<column name="MaintLogID1">BRMR35025363</column>
</row>
<row>
<column name="Notes">completed as per pm
inspected and grease packing
belts in good condition
pump turns freely
ran up and tested
all satisfactory</column>
<column name="MaintLogID1">BRMR35025364</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
Damper locating pin missing, new pin taper pin fitted
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025365</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025366</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025367</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025368</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025369</column>
</row>
<row>
<column name="Notes">Fan housing and fastenings inspected,
No abnormal noise noted when fan is running </column>
<column name="MaintLogID1">BRMR35025370</column>
</row>
<row>
<column name="Notes">Not carried out this time.
Still awaiting arrival of test kit.</column>
<column name="MaintLogID1">BRMR35025371</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
All expiry dates checked. Pyrotechnics for the lifeboats are put on order
list.
</column>
<column name="MaintLogID1">BRMR35025372</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Batteries replaced with the new ones (expiry date March 2012).
Pyrotechnics on order.
</column>
<column name="MaintLogID1">BRMR35025373</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Batteries replaced with the new ones (expiry date March 2012).
Pyrotechnics on order.
</column>
<column name="MaintLogID1">BRMR35025374</column>
</row>
<row>
<column name="Notes">All air receiver v/vs operated - all found
free to move.</column>
<column name="MaintLogID1">BRMR35025375</column>
</row>
<row>
<column name="Notes">Cut in/out tested satisfactory. One compressor
tripped standby m/c starts.
All satisfactory</column>
<column name="MaintLogID1">BRMR35025376</column>
</row>
<row>
<column name="Notes">Cut in/out tested satisfactory. One compressor
tripped standby m/c starts.
All satisfactory</column>
<column name="MaintLogID1">BRMR35025377</column>
</row>
<row>
<column name="Notes">All rotary sootblowers greased during weekly
safety routines. Grease checked, all satisfactory.</column>
<column name="MaintLogID1">BRMR35025378</column>
</row>
<row>
<column name="Notes">All rotary sootblowers greased during weekly
safety routines. Grease checked, all satisfactory.</column>
<column name="MaintLogID1">BRMR35025379</column>
</row>
<row>
<column name="Notes">All alrams and trips fully operational.
High air temp alarm @105 Deg C and trip @110 Deg C.
Low and low low resevoir pressure tested in both bottles - operational,
stby compressors start.
NB Oil resevoir press was vented using v/v fitted on this m/c. The
safety valve was not manually lifted.</column>
<column name="MaintLogID1">BRMR35025380</column>
</row>
<row>
<column name="Notes">
Moisture indicator showing Deep Green.
</column>
<column name="MaintLogID1">BRMR35025401</column>
</row>
<row>
<column name="Notes">Not carried out due to vessel's trading
pattern.</column>
<column name="MaintLogID1">BRMR35025402</column>
</row>
<row>
<column name="Notes">All OK. Spares located in Safety Gear Locker.
</column>
<column name="MaintLogID1">BRMR35025403</column>
</row>
<row>
<column name="Notes">Test carried out OK.</column>
<column name="MaintLogID1">BRMR35025417</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All OK.</column>
<column name="MaintLogID1">BRMR35025418</column>
</row>
<row>
<column name="Notes">Elevator not in use</column>
<column name="MaintLogID1">BRMR35025419</column>
</row>
<row>
<column name="Notes">Inspected cleaned no defects observed</column>
<column name="MaintLogID1">BRMR35025420</column>
</row>
<row>
<column name="Notes">Inspected cleaned no defects observed</column>
<column name="MaintLogID1">BRMR35025421</column>
</row>
<row>
<column name="Notes">Function of all solonoids observed.
release alarms tested,
purifier room valve internally inspected</column>
<column name="MaintLogID1">BRMR35025422</column>
</row>
<row>
<column name="Notes">Carried out by shore personel singapore &
Korea</column>
<column name="MaintLogID1">BRMR35025423</column>
</row>
<row>
<column name="Notes">Pump has no leakage or abnormal noise -
running pressures are satisfactory.
Temperature control wax pot removed and inspected, all ok. This was then
tested and found to actuate correctly.
Hours: 8537</column>
<column name="MaintLogID1">BRMR35025428</column>
</row>
<row>
<column name="Notes">Outboard gauge glass removed due to leakage.
Spare fitted.
</column>
<column name="MaintLogID1">BRMR35025517</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All OK.</column>
<column name="MaintLogID1">BRMR35025518</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Alarms tested OK.</column>
<column name="MaintLogID1">BRMR35025519</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Working correctly.</column>
<column name="MaintLogID1">BRMR35025520</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Route 12 & 13 tested OK.</column>
<column name="MaintLogID1">BRMR35025521</column>
</row>
<row>
<column name="Notes">Lamps switched on for 4 hrs.
Insulation readings OK.</column>
<column name="MaintLogID1">BRMR35025522</column>
</row>
<row>
<column name="Notes">Received 6 new ignitors ( 3 left side & 3
right side)
All fitted to the lamps with low insulation on the fore mast:
STBD lower AFT facing
STBD upper AFT facing
PORT upper AFT facing
Original ACB from the EM'CY SWBD has been put back to No.1 bus-tie
position.
Settings for overcurrent found different than No.2 bus-tie breaker.
Presumably they were changed to suit for CSB settings.
This was corrected by setting No.1 bus-tie breaker as No.2 bus-tie breaker
which is:
</column>
<column name="MaintLogID1">BRMR35025525</column>
</row>
<row>
<column name="Notes">All level alarms and temperture trips tested
and all in good order</column>
<column name="MaintLogID1">BRMR35025526</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025527</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025528</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025529</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025530</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025531</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025532</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025533</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025534</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025535</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025536</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025537</column>
</row>
<row>
<column name="Notes">dranes proved clear, operation of compressore
checkes ,fan & belts inspected,
leak test carried out,electrical fittings checked, fan greased.</column>
<column name="MaintLogID1">BRMR35025538</column>
</row>
<row>
<column name="Notes">As per instructions for merchant</column>
<column name="MaintLogID1">BRMR35025539</column>
</row>
<row>
<column name="Notes">As per instructions for merchant</column>
<column name="MaintLogID1">BRMR35025540</column>
</row>
<row>
<column name="Notes">Cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025541</column>
</row>
<row>
<column name="Notes">Not carried out elivator not in use.</column>
<column name="MaintLogID1">BRMR35025542</column>
</row>
<row>
<column name="Notes">Carried out with meter ansd soapy
water</column>
<column name="MaintLogID1">BRMR35025543</column>
</row>
<row>
<column name="Notes">Carried out with meter ansd soapy
water</column>
<column name="MaintLogID1">BRMR35025544</column>
</row>
<row>
<column name="Notes">Carried out with meter ansd soapy
water</column>
<column name="MaintLogID1">BRMR35025545</column>
</row>
<row>
<column name="Notes">no defects observed all fittings
tight</column>
<column name="MaintLogID1">BRMR35025546</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35025547</column>
</row>
<row>
<column name="Notes">Flushed</column>
<column name="MaintLogID1">BRMR35025548</column>
</row>
<row>
<column name="Notes">Ran on aux condenser</column>
<column name="MaintLogID1">BRMR35025549</column>
</row>
<row>
<column name="Notes">Tested</column>
<column name="MaintLogID1">BRMR35025550</column>
</row>
<row>
<column name="Notes">All equiptment checked system visually
inspected end to end</column>
<column name="MaintLogID1">BRMR35025551</column>
</row>
<row>
<column name="Notes">zeroed as per manufactures
instructions</column>
<column name="MaintLogID1">BRMR35025552</column>
</row>
<row>
<column name="Notes">zeroed as per manufactures
instructions</column>
<column name="MaintLogID1">BRMR35025553</column>
</row>
<row>
<column name="Notes">amps 3.4
hours 16997.9
no defects observed</column>
<column name="MaintLogID1">BRMR35025554</column>
</row>
<row>
<column name="Notes">amps 3.5
hours 15561.3
no defects observed</column>
<column name="MaintLogID1">BRMR35025555</column>
</row>
<row>
<column name="Notes">Carried out as per instructions in
workorder</column>
<column name="MaintLogID1">BRMR35025556</column>
</row>
<row>
<column name="Notes">All valves inspected, fittings checked.
operation of valves observed over past few days</column>
<column name="MaintLogID1">BRMR35025557</column>
</row>
<row>
<column name="Notes">All valves inspected, fittings checked.
operation of valves observed over past few days</column>
<column name="MaintLogID1">BRMR35025558</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025559</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025560</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025561</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025562</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025563</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025564</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025565</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025566</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025567</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025568</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025569</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025570</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025571</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025572</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025573</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025574</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025575</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025576</column>
</row>
<row>
<column name="Notes">Phone tested from machine room to CCR loud and
clear</column>
<column name="MaintLogID1">BRMR35025577</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025578</column>
</row>
<row>
<column name="Notes">readings taken and unit checked</column>
<column name="MaintLogID1">BRMR35025579</column>
</row>
<row>
<column name="Notes">Not carried out this time.
Still awaiting arrival of test kit.</column>
<column name="MaintLogID1">BRMR35025580</column>
</row>
<row>
<column name="Notes">Tested. Alarms correct and valves
operate.</column>
<column name="MaintLogID1">BRMR35025581</column>
</row>
<row>
<column name="Notes">Pump greased.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025582</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025583</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025584</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025585</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025586</column>
</row>
<row>
<column name="Notes">completed a per pm
satisfactory
</column>
<column name="MaintLogID1">BRMR35025587</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025588</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025589</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory</column>
<column name="MaintLogID1">BRMR35025590</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025591</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025592</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025593</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025594</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025595</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025596</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025597</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025598</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025599</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025600</column>
</row>
<row>
<column name="Notes">completed as per pm
unit tested
all found satisfactory </column>
<column name="MaintLogID1">BRMR35025601</column>
</row>
<row>
<column name="Notes">completed as per pm
filter removed and cleaned
filter put back and cover tightened
unit tested and check for leaks
all found satisfactory </column>
<column name="MaintLogID1">BRMR35025602</column>
</row>
<row>
<column name="Notes">completed as per pm
satisfactory </column>
<column name="MaintLogID1">BRMR35025603</column>
</row>
<row>
<column name="Notes">completed as per pm
all valves free to turn
all found satisfactory </column>
<column name="MaintLogID1">BRMR35025604</column>
</row>
<row>
<column name="Notes">One man bridge alarm tested as per PM routine
and operated correctly.
All okay</column>
<column name="MaintLogID1">BRMR35025605</column>
</row>
<row>
<column name="Notes">completed as per pm
all found satisfactory </column>
<column name="MaintLogID1">BRMR35025606</column>
</row>
<row>
<column name="Notes">completed as per pm
all valves free to turn and greased
all filters cleaned
all found satisfactory </column>
<column name="MaintLogID1">BRMR35025607</column>
</row>
<row>
<column name="Notes">PM completed</column>
<column name="MaintLogID1">BRMR35025611</column>
</row>
<row>
<column name="Notes">CTS back up carried out and emailed to Saab as
per AMOS procedure.</column>
<column name="MaintLogID1">BRMR35025612</column>
</row>
<row>
<column name="Notes">Water bottles charged as per pm
all fixtures and fittings checked
operation of solonoid observed</column>
<column name="MaintLogID1">BRMR35025613</column>
</row>
<row>
<column name="Notes">Carried out</column>
<column name="MaintLogID1">BRMR35025614</column>
</row>
<row>
<column name="Notes">Oil, HP alarms tested Lp cut out observed
operation of unloader checked on both units.
oil 1.6 at 0.9 lp
lp 0.3
hp 21.5</column>
<column name="MaintLogID1">BRMR35025615</column>
</row>
<row>
<column name="Notes">Both condensers checked from fwd end no
defects observed,brushed through from this end then flushed.</column>
<column name="MaintLogID1">BRMR35025616</column>
</row>
<row>
<column name="Notes">All alarms and trips testedn as per pm.
When blowers started they tripped out due to dryers failing , fault
indicated valve failure . Defect traced
valve limit switch cam had vibrated loose on blower inlet valve to dryers
on No 2 unit.
Defect to rectify on temperature Danfoss unit TZAH4407.(Temperature after
scrubber tower). All other systems in good working order.</column>
<column name="MaintLogID1">BRMR35025617</column>
</row>
<row>
<column name="Notes">Completed as per pm. New cover gaskets
fabricated. New anodes fitted to inlet/outlet SW box.
2.0218.01.042 used 4 ROB 12.</column>
<column name="MaintLogID1">BRMR35025618</column>
</row>
<row>
<column name="Notes">Completed as per pm. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025619</column>
</row>
<row>
<column name="Notes">completed as per pm.
relief valve tested found in good condition.
valves in good condition.
buckets, rings, liners, and bearings in good condition.
holding down bolts tight.
pressure gauges tested and found to be in good working order.
pump reassembled.
pump then tested and everything good.
</column>
<column name="MaintLogID1">BRMR35025620</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 Megs
All tight and secure</column>
<column name="MaintLogID1">BRMR35025621</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 Megs
All tight and secure</column>
<column name="MaintLogID1">BRMR35025622</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All in good working order.</column>
<column name="MaintLogID1">BRMR35025623</column>
</row>
<row>
<column name="Notes">Completed as per PM.
motor meggered > 100 megs.
heater meggered > 100 megs
all connection stight and secure.
main contactor - fixed and moving contacts cleaned up , still in good
working order.</column>
<column name="MaintLogID1">BRMR35025624</column>
</row>
<row>
<column name="Notes">Completed as per PM.
motor meggered > 100 megs.
heater meggered > 100 megs
all connection stight and secure.
main contactor - fixed and moving contacts cleaned up , still in good
working order.</column>
<column name="MaintLogID1">BRMR35025625</column>
</row>
<row>
<column name="Notes">Completed as per PM.
motor meggered > 100 megs
all tight and secure.</column>
<column name="MaintLogID1">BRMR35025626</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All operational.</column>
<column name="MaintLogID1">BRMR35025627</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All operational.</column>
<column name="MaintLogID1">BRMR35025628</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Slipring cleaned up.</column>
<column name="MaintLogID1">BRMR35025629</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Slipring cleaned up.
Brushes OK.</column>
<column name="MaintLogID1">BRMR35025630</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Equipment operational.
Both transducers cleaned up - See AMOS MER/06/06401</column>
<column name="MaintLogID1">BRMR35025631</column>
</row>
<row>
<column name="Notes">Completed as per PM.
tested OK.</column>
<column name="MaintLogID1">BRMR35025632</column>
</row>
<row>
<column name="Notes">Lift not in use at the moment.</column>
<column name="MaintLogID1">BRMR35025633</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All alarms operational.</column>
<column name="MaintLogID1">BRMR35025634</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Both alarms operational.</column>
<column name="MaintLogID1">BRMR35025635</column>
</row>
<row>
<column name="Notes">Completed as per PM.
no discrepancies noticed.</column>
<column name="MaintLogID1">BRMR35025636</column>
</row>
<row>
<column name="Notes">lamps tested for 4 hrs.
Insulation readings above 5 megs</column>
<column name="MaintLogID1">BRMR35025637</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Route 14, 15 & 17 tested</column>
<column name="MaintLogID1">BRMR35025638</column>
</row>
<row>
<column name="Notes">PM completed as per work order all alarms and
trips functioned as required no defects to report</column>
<column name="MaintLogID1">BRMR35025639</column>
</row>
<row>
<column name="Notes">Both Vapour valves operated as per work order
all free and in good order. Unable to operate bog master valve this period
as
boilers on full gas while on passage to Korea. When boilers go off gas
while complete PM.</column>
<column name="MaintLogID1">BRMR35025640</column>
</row>
<row>
<column name="Notes">PM completed as per work order no defects to
report this period</column>
<column name="MaintLogID1">BRMR35025641</column>
</row>
<row>
<column name="Notes">Dearator shut down and depresurised.
The drain valve bonnet gasket renewed/
Further another leaking flange further upstream of the same line inside the
IG room was also found leaking. Flange gasket replaced</column>
<column name="MaintLogID1">BRMR35025642</column>
</row>
<row>
<column name="Notes">New regulator fitted</column>
<column name="MaintLogID1">BRMR35025643</column>
</row>
<row>
<column name="Notes">Carried out as per pm. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025644</column>
</row>
<row>
<column name="Notes">Cooler found to be quiet dirty. Rodded through
and washed with water.
All 8 anodes replaced and new o rings fitted.
Part 2.0218.01.042 used 8 rob 3</column>
<column name="MaintLogID1">BRMR35025645</column>
</row>
<row>
<column name="Notes">whistle checked and tested found ok</column>
<column name="MaintLogID1">BRMR35025646</column>
</row>
<row>
<column name="Notes">Completed as per pm.
very small amount of sludge found.
Cleaned and replaced.
Mag filter found to be clean.</column>
<column name="MaintLogID1">BRMR35025647</column>
</row>
<row>
<column name="Notes">Filter inspected.
Clean and in good condition.
Not replaced this time.</column>
<column name="MaintLogID1">BRMR35025648</column>
</row>
<row>
<column name="Notes">Gearing inspected. Gear teeth in good
condition with no marking evident. Lubrication ok. Split pins in place on
castlelated nuts</column>
<column name="MaintLogID1">BRMR35025649</column>
</row>
<row>
<column name="Notes">As weekly test results are good tank not
drained, water visually inspected and found to be clear.
5 l chemical added and level brought up to top test cock
</column>
<column name="MaintLogID1">BRMR35025650</column>
</row>
<row>
<column name="Notes">oil not changed as was done last month, sight
glass still clear.
System all apears in good condition no defects observed</column>
<column name="MaintLogID1">BRMR35025651</column>
</row>
<row>
<column name="Notes">1 filter removed and found to be clean so
other 3 inspected externally.
Trunking inspected and found to be free of water, draines proved
clear.</column>
<column name="MaintLogID1">BRMR35025652</column>
</row>
<row>
<column name="Notes">1 filter removed and found to be clean so
other 3 inspected externally.
Trunking inspected and found to be free of water, draines proved
clear.</column>
<column name="MaintLogID1">BRMR35025653</column>
</row>
<row>
<column name="Notes">Completed as per pm.
All trips and alarms operating satisfactorily.
Unit renturned to normal condition and run on test.
All ok.
Point of note.
To reset the overspeed trip. You need to switch off the
output to governer controller in the emerg switchboard room.</column>
<column name="MaintLogID1">BRMR35025654</column>
</row>
<row>
<column name="Notes">Completed as per pm. No defects to report.
</column>
<column name="MaintLogID1">BRMR35025655</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist -
operational.</column>
<column name="MaintLogID1">BRMR35025656</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist -
operational.</column>
<column name="MaintLogID1">BRMR35025657</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist -
operational.</column>
<column name="MaintLogID1">BRMR35025658</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist -
operational.</column>
<column name="MaintLogID1">BRMR35025659</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist -
operational.</column>
<column name="MaintLogID1">BRMR35025660</column>
</row>
<row>
<column name="Notes">Unit removed for test and calibration using 24
volt suppy in eto's shop and hot pot.
Unit set to require range and replaced on plant.</column>
<column name="MaintLogID1">BRMR35025661</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025662</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025663</column>
</row>
<row>
<column name="Notes">Tested as per PM, fully operational.</column>
<column name="MaintLogID1">BRMR35025664</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025665</column>
</row>
<row>
<column name="Notes">Fully operational.</column>
<column name="MaintLogID1">BRMR35025666</column>
</row>
<row>
<column name="Notes">completed as per pm
comp priority
3 1
1 2</column>
<column name="MaintLogID1">BRMR35025670</column>
</row>
<row>
<column name="Notes">Completed as per pm
Comp Priority
1 1
3 2</column>
<column name="MaintLogID1">BRMR35025671</column>
</row>
<row>
<column name="Notes">Completed as per pm
Comp Priority
1 1
3 2</column>
<column name="MaintLogID1">BRMR35025672</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35025673</column>
</row>
<row>
<column name="Notes">
</column>
<column name="MaintLogID1">BRMR35025674</column>
</row>
<row>
<column name="Notes">Completed as per pm.</column>
<column name="MaintLogID1">BRMR35025675</column>
</row>
<row>
<column name="Notes">Completed as per pm.</column>
<column name="MaintLogID1">BRMR35025676</column>
</row>
<row>
<column name="Notes">Completed as per pm.</column>
<column name="MaintLogID1">BRMR35025677</column>
</row>
<row>
<column name="Notes">completed as per PM, no defects
found.</column>
<column name="MaintLogID1">BRMR35025678</column>
</row>
<row>
<column name="Notes">as per routinees sheet</column>
<column name="MaintLogID1">BRMR35025679</column>
</row>
<row>
<column name="Notes">as per routinees sheet</column>
<column name="MaintLogID1">BRMR35025680</column>
</row>
<row>
<column name="Notes">as per routinees sheet</column>
<column name="MaintLogID1">BRMR35025681</column>
</row>
<row>
<column name="Notes">Filter cleaned when units changed
over</column>
<column name="MaintLogID1">BRMR35025682</column>
</row>
<row>
<column name="Notes">All sets & botles inspected. All pressures
within limts.</column>
<column name="MaintLogID1">BRMR35025683</column>
</row>
<row>
<column name="Notes">Fire pump tested. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025684</column>
</row>
<row>
<column name="Notes">D/Alt run on test. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025685</column>
</row>
<row>
<column name="Notes">Feed pump run up. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025686</column>
</row>
<row>
<column name="Notes">Feed pump run up. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025687</column>
</row>
<row>
<column name="Notes">All valves found free to move and spindles
greased.</column>
<column name="MaintLogID1">BRMR35025688</column>
</row>
<row>
<column name="Notes">Pump found free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025689</column>
</row>
<row>
<column name="Notes">Pump found free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025690</column>
</row>
<row>
<column name="Notes">Pump found free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025691</column>
</row>
<row>
<column name="Notes">Pump found free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025692</column>
</row>
<row>
<column name="Notes">Pump found free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025693</column>
</row>
<row>
<column name="Notes">Pump is pumping fine hrs are only 32 hours
performance good
checked holding down bolts
greased, and cleaned filter</column>
<column name="MaintLogID1">BRMR35025694</column>
</row>
<row>
<column name="Notes">air whistle checked and tested
all found satisfactory</column>
<column name="MaintLogID1">BRMR35025695</column>
</row>
<row>
<column name="Notes">309 310 293 295
310 310 295 302 290
302 290 104.3 99.6 104.4 100.2 242.5 242.3
100.3 100 </column>
<column name="MaintLogID1">BRMR35025696</column>
</row>
<row>
<column name="Notes">Temporary repair carried out by thistle
bonding the cracks from the inside.
</column>
<column name="MaintLogID1">BRMR35025698</column>
</row>
<row>
<column name="Notes">Inspection carried out 13/03/2007
MER/G/006
Cell's voltage:
1 2,06
2 2,05
3 2,04
4 2,04
5 2,05
6 2,05
7 2,05
8 2,05
9 2,04
10 2,04
11 2,05
12 2,07
total 24,50 V
charging current 22A
cells voltage:
1 2,27
2 2,33
3 2,27
4 2,28
5 2,27
6 2,27
7 2,28
8 2,27
9 2,34
10 2,34
11 2,27
12 2,27
total 27,39</column>
<column name="MaintLogID1">BRMR35025702</column>
</row>
<row>
<column name="Notes">Found no.1 tank radar giving not correct
readings.
Tx - failure on the screen, not possible to restart tank from the CTS
station.
</column>
<column name="MaintLogID1">BRMR35025772</column>
</row>
<row>
<column name="Notes">See 12 Monthly PM this month for
details.</column>
<column name="MaintLogID1">BRMR35025773</column>
</row>
<row>
<column name="Notes">See 12 Monthly PM this month for
details.</column>
<column name="MaintLogID1">BRMR35025774</column>
</row>
<row>
<column name="Notes">Rescue boat Raw water circuit anodes
inspected.
Two anodes needing replacing these were No. 2 on drawing number 28 (air
cooler) and No.3 on Drawing 29 (water cooler).
Both drawings are on page 63 of the manual.
As we have no spaeres onboard, the plugs were drilled and tapped to M10 to
remove any of the old anode.
New zinc anodes were then turned and fitted to the old plugs. These were
sealed around the thread with a gasket as this is where
the corrosion is causing faults.
Anodes to be inspected after every time the boat is in the water. </column>
<column name="MaintLogID1">BRMR35025775</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.
</column>
<column name="MaintLogID1">BRMR35025776</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025777</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025778</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025779</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025780</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025781</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025782</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025783</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025784</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35025785</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025786</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025787</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025788</column>
</row>
<row>
<column name="Notes">Completed as per PM, all operational.</column>
<column name="MaintLogID1">BRMR35025789</column>
</row>
<row>
<column name="Notes">Completed as per pm
Comp Priority
3 1
1 2</column>
<column name="MaintLogID1">BRMR35025790</column>
</row>
<row>
<column name="Notes">Completed as per pm
Comp Priority
3 1
1 2</column>
<column name="MaintLogID1">BRMR35025791</column>
</row>
<row>
<column name="Notes">Completed as per pm
Comp Priority
3 1
1 2</column>
<column name="MaintLogID1">BRMR35025792</column>
</row>
<row>
<column name="Notes">Fire dampers operated during weekly safety
routines. All fully operational.</column>
<column name="MaintLogID1">BRMR35025793</column>
</row>
<row>
<column name="Notes">Calorifier checked , all fully operational.
Running on electric heater. All pressures and temps satisfactory.
All others sets in good condition. All others sets holing their
pressures.</column>
<column name="MaintLogID1">BRMR35025817</column>
</row>
<row>
<column name="Notes">Coating in Excellent condition. No ingress of
water apparent, save slight patches below hatch plate.
All pipe flanges appear to be tight.
No evidence of structure deformation.
On the void space side of the feed through pipe for Em. Cargo Pumps cables,
the securing fitting is hanging loose. Deck side of Pipe is secure. No
evidence of water ingress through pipe.
Drydock spec written by C/E for re-fitting of cable fixture.</column>
<column name="MaintLogID1">BRMR35025818</column>
</row>
<row>
<column name="Notes">Completed as per pm. No defects to
report.</column>
<column name="MaintLogID1">BRMR35025819</column>
</row>
<row>
<column name="Notes">Accomodation :
Allyway escape lights and cargo switchboard room 1 & 2 exit light were
turned off for 30 min, to check the batteries. Only two batteries
didn't pass the test and need to be changed:
- Cargo switchboard room1 exit light on the top of the doors between Cargo
Switchboard Room's was working 25 min
- A-deck staircase battery light not working
Machinery spaces:
All emergency lights in the all engine room spaces ( all deck's,
emergancy gen room, IG room etc.) were turned off for 30 min. All batteries
passed the test.
</column>
<column name="MaintLogID1">BRMR35025820</column>
</row>
<row>
<column name="Notes">Completed as per PM.
motor meggered > 100 megs.
all in good working order.</column>
<column name="MaintLogID1">BRMR35025821</column>
</row>
<row>
<column name="Notes">Completed as per PM.
motor meggered > 100 megs.
all in good working order.</column>
<column name="MaintLogID1">BRMR35025822</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Thermostats checked with IR gun.
Cut in and off signals working correctly.</column>
<column name="MaintLogID1">BRMR35025823</column>
</row>
<row>
<column name="Notes">Completed as per PM.
batteries tested OK.
volatge readings:
All okay.</column>
<column name="MaintLogID1">BRMR35025838</column>
</row>
<row>
<column name="Notes">System tested by soapt water and electric
meter</column>
<column name="MaintLogID1">BRMR35025839</column>
</row>
<row>
<column name="Notes">System tested by soapt water and electric
meter</column>
<column name="MaintLogID1">BRMR35025840</column>
</row>
<row>
<column name="Notes">System tested by soapt water and electric
meter</column>
<column name="MaintLogID1">BRMR35025841</column>
</row>
<row>
<column name="Notes">steering gear room inspected</column>
<column name="MaintLogID1">BRMR35025842</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35025843</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35025844</column>
</row>
<row>
<column name="Notes">Ran on aux condenser</column>
<column name="MaintLogID1">BRMR35025845</column>
</row>
<row>
<column name="Notes">Function tested</column>
<column name="MaintLogID1">BRMR35025846</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025847</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025848</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025849</column>
</row>
<row>
<column name="Notes">Filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35025850</column>
</row>
<row>
<column name="Notes">Sample of oil sent away for testing any action
required will be carried out when results arrive</column>
<column name="MaintLogID1">BRMR35025851</column>
</row>
<row>
<column name="Notes">Completed as per W.O.
All in good order</column>
<column name="MaintLogID1">BRMR35025852</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35025853</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35025854</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35025855</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order</column>
<column name="MaintLogID1">BRMR35025856</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order</column>
<column name="MaintLogID1">BRMR35025857</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35025858</column>
</row>
<row>
<column name="Notes">Unit is running.</column>
<column name="MaintLogID1">BRMR35025859</column>
</row>
<row>
<column name="Notes">LD is currently running.</column>
<column name="MaintLogID1">BRMR35025860</column>
</row>
<row>
<column name="Notes">Drains checked. All clear of water.</column>
<column name="MaintLogID1">BRMR35025861</column>
</row>
<row>
<column name="Notes">Alarms tested. all ok</column>
<column name="MaintLogID1">BRMR35025862</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order</column>
<column name="MaintLogID1">BRMR35025863</column>
</row>
<row>
<column name="Notes">Completed as per W.O</column>
<column name="MaintLogID1">BRMR35025864</column>
</row>
<row>
<column name="Notes">All valves operated.</column>
<column name="MaintLogID1">BRMR35025865</column>
</row>
<row>
<column name="Notes">All points lubricated. New cover made for
Rescue Boat Seat.</column>
<column name="MaintLogID1">BRMR35025866</column>
</row>
<row>
<column name="Notes">Tank 4
CN430 - 1.6% O2
CN446 - 1.5% O2
CN426 - 1.7% O2
CN425 - 1.5% O2
Low and low low resevoir pressure tested in both bottles - operational,
stby compressors start.
NB Oil resevoir press was vented using v/v fitted on this m/c. The
safety valve was not manually lifted.</column>
<column name="MaintLogID1">BRMR35025917</column>
</row>
<row>
<column name="Notes">Ran on test as per routine, no
problems.</column>
<column name="MaintLogID1">BRMR35025918</column>
</row>
<row>
<column name="Notes">No.2 LPSG Feed p/p mech. seal leaking. Pump
dismantled and seal found to be worn and cracked.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35025921</column>
</row>
<row>
<column name="Notes">Purge mufflers replaced as spares have
arrived.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35025922</column>
</row>
<row>
<column name="Notes">Oil separator inserts changed after 3000 hours
in use.
Counter reset
This PM has been brought forward to align it with the machines actual
running hours.
Hours: 11855</column>
<column name="MaintLogID1">BRMR35025923</column>
</row>
<row>
<column name="Notes">Pump run on load.</column>
<column name="MaintLogID1">BRMR35025924</column>
</row>
<row>
<column name="Notes">Completed as per W.O.
All in good working order.</column>
<column name="MaintLogID1">BRMR35025925</column>
</row>
<row>
<column name="Notes">All valve's operated.
The 2nd non-return valve to deck was very stiff. It will require removal
and o/h after the vessel has discharged.</column>
<column name="MaintLogID1">BRMR35025926</column>
</row>
<row>
<column name="Notes">High pressure trip
low presure cut out
oil presure trip
discharge temperature
oil temperature
Fitted a new sample pump due to bad vibs from the old unit.
New diaphragm's fitted to both pump's
New 50% LEL sensor fitted due the problems calibrating the sensor. We could
not pick up any reading
when the span gas was on the unit, the output from both old and new units
where stuck at 2mA. To kick
start the unit we put the unit into the calibration mode and fed a false
output from the unit into the card. 12.7mA
is an output of 30%LEL. The unit was then tested and read correctly.
We continued to have problem's with no flow on the IR sensor and since
found a lose 24V supply wire lose in its
terminal block. The unit has been working correctly since.
We will leave the new sensor in place for acouple of weeks just to prove
it, then change back over and fit the old
unit. </column>
<column name="MaintLogID1">BRMR35025938</column>
</row>
<row>
<column name="Notes">Purifier dismantled & inspected - no signs
of wear or damge.
Stripped and cleaned, very light deposits found on disk stack and sliding
bowl.
Oil paring disc showing signs of wear around eye and on discharge ports,
not deemed worn
enough to be replaced.
All seals and 'o' rings inspected - all in good condition - these
were NOT replaced.
</column>
<column name="MaintLogID1">BRMR35025941</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No discreapancies noticed.</column>
<column name="MaintLogID1">BRMR35025942</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Lights on for 3 hrs.
insulation readings correct.</column>
<column name="MaintLogID1">BRMR35025943</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Route 9,10 and 11 tested OK.</column>
<column name="MaintLogID1">BRMR35025944</column>
</row>
<row>
<column name="Notes">DSC call carried out.
No ackn. received.
No entry to GMDSS log book.</column>
<column name="MaintLogID1">BRMR35025945</column>
</row>
<row>
<column name="Notes">D/Alt run on load.</column>
<column name="MaintLogID1">BRMR35025946</column>
</row>
<row>
<column name="Notes">Fire pump run on test as per new instructions.
One hose on the focsle & one hose on the funnel deck.</column>
<column name="MaintLogID1">BRMR35025947</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025948</column>
</row>
<row>
<column name="Notes">Feed pump run.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025949</column>
</row>
<row>
<column name="Notes">Feed pump run.
No defects to report.</column>
<column name="MaintLogID1">BRMR35025950</column>
</row>
<row>
<column name="Notes">All 4 filters opened up and inspected.
Primary basket filters blown through with air.
Secondary filter cartridges changed.
After several minutes of opepration temp of power pack motor was 35degC,
Pump was 52degC and the
v/v block was 44degC.
System oil was clear and bright, Hyd header tk low lvl alm
tested.</column>
<column name="MaintLogID1">BRMR35026002</column>
</row>
<row>
<column name="Notes">Thruster unit swung 10deg Port and Stb'd;
Press 1.2 and 1MPa respectivly.
After several minutes of opepration temp of power pack motor was 35degC,
Pump was 52degC and the
v/v block was 44degC.
System oil was clear and bright, Hyd header tk low lvl alm tested.
All relavent points greased</column>
<column name="MaintLogID1">BRMR35026003</column>
</row>
<row>
<column name="Notes">Dryer inspected - no problems found. Residual
pressure during regeneration is >0.01 bar.
Gasket from service kit used between separator box and oil resevoir flange.
NB.
NB.
NB.
A "Used but Good" seal was found and used as it was in better
condition than the removed seal.
This was only good for about 12 hours as the pump is now leaking again.
Gearbox oil inspected and found in good condition, this was NOT changed on
this occasion.
Gearbox oil inspected and found in good condition, this was NOT changed on
this occasion.
All operational.
</column>
<column name="MaintLogID1">BRMR35026050</column>
</row>
<row>
<column name="Notes">Reported motor trip.
found one of the moving contact burnt out on the main contactor.
used spare contact set from spares - one moving contact and two fixed
contacts.
this was fitted and motor tested OK.
Temp. 46 deg C
Phase bridge 2 mV
Gyro current 256 mA</column>
<column name="MaintLogID1">BRMR35026057</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All checked and found OK.
Temp. 48 deg C
Phase bridge 2 mV
Gyro current 247 mA</column>
<column name="MaintLogID1">BRMR35026058</column>
</row>
<row>
<column name="Notes">Pump free to move.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026059</column>
</row>
<row>
<column name="Notes">Completed as per pm. Hand start used.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026060</column>
</row>
<row>
<column name="Notes">Alarm & pneumatic drain valve operation
checked - OK</column>
<column name="MaintLogID1">BRMR35026061</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026062</column>
</row>
<row>
<column name="Notes">Lion Alcometer calibrated and tested as per PM
routine.
Printer tested and functioning well after being allowed to charge for a few
minutes.</column>
<column name="MaintLogID1">BRMR35026063</column>
</row>
<row>
<column name="Notes">One man bridge alarm alarm tested as per PM
routine.
</column>
<column name="MaintLogID1">BRMR35026094</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
em'cy gen batteries.
GOVERNOR:
float voltage:
Batt.1 13,00
Batt.2 13,03
Batt.1 12,56
Batt.2 12,59
One thing for steering control is not correct - after em'cy generator
load test auto pilot is not fallowing heading after next way point.
Noticed that during load test for generator power supply is lost for speed
log (no UPS).
When problem with changing heading appears we have to reset speed logs by
switching off and on main breaker for processor units.
</column>
<column name="MaintLogID1">BRMR35026098</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No problems found.</column>
<column name="MaintLogID1">BRMR35026099</column>
</row>
<row>
<column name="Notes">No problems reported.
All operational at the moment.</column>
<column name="MaintLogID1">BRMR35026100</column>
</row>
<row>
<column name="Notes">All tests complete satisfactorily and printed
out.</column>
<column name="MaintLogID1">BRMR35026101</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All fire door operational - tested manually and tested during a drill.
Found some of the door not indicating on IAS screen though - ( faulty
proximity switches) - this will be investigated.</column>
<column name="MaintLogID1">BRMR35026102</column>
</row>
<row>
<column name="Notes">No problems reported.
all operational. </column>
<column name="MaintLogID1">BRMR35026103</column>
</row>
<row>
<column name="Notes">coupling inspested
grease changed</column>
<column name="MaintLogID1">BRMR35026104</column>
</row>
<row>
<column name="Notes">Filter changed for spare</column>
<column name="MaintLogID1">BRMR35026105</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026106</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition.</column>
<column name="MaintLogID1">BRMR35026107</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35026108</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35026109</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35026110</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good order.</column>
<column name="MaintLogID1">BRMR35026111</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs.
Heater meggered > 100 megs.
</column>
<column name="MaintLogID1">BRMR35026114</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs
Heater meggered > 100 megs.
</column>
<column name="MaintLogID1">BRMR35026115</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs
Heater meggered > 100 megs</column>
<column name="MaintLogID1">BRMR35026116</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs.
heater meggered > 100 megs.
satisfactory condition.</column>
<column name="MaintLogID1">BRMR35026117</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Unit fully operational.
Tested with full weather printout.
Not often used with V-sat onboard.</column>
<column name="MaintLogID1">BRMR35026118</column>
</row>
<row>
<column name="Notes">Fan filters replaced with new ones and all
compartment cleaned up.
All fans working OK.
System operational with no defects.
Waveguide connections OK.</column>
<column name="MaintLogID1">BRMR35026119</column>
</row>
<row>
<column name="Notes">Fan filters replaced with new ones on the
computer side.
All compartment cleaned up.
Ongoing problem with motor brushes. At the moment they are OK. new set
onboard just in case.
New motor arrived as well and probably with nearest occasion new motor unit
will be fitted.</column>
<column name="MaintLogID1">BRMR35026120</column>
</row>
<row>
<column name="Notes">Defective smoke head above No.2 T/A - zone 5
head 64
this was replaced with new ones and tested OK.</column>
<column name="MaintLogID1">BRMR35026121</column>
</row>
<row>
<column name="Notes">defective ignitor in one of the flood light on
top of the deck house (stbd side)
no spares on board but used old ignitor from the electrical workshop.
All sealed and tested OK.</column>
<column name="MaintLogID1">BRMR35026122</column>
</row>
<row>
<column name="Notes">Reported that OS 5 station failed with
"system dysk error" message on the screen.
Found disc not operational at all when tried disc in library computer.
New disc has been used.
ghost program has been used to make partition on the disc and Kongsberg
recovery discs have been downloaded.
All tested and found Ok apart from Running Hours. Running hours sheet was
found completely blank.
Check that the alarm is gone, and that the running hours are correct.
====================================================================
Traced problem to false signal from PLC controller for No.2 boiler (PSM 09)
Reset has been carried out and found all OK.
It takes time to reboot whole system - best idea is not to touch any push
buttons on the keypad until system fully rebooted.</column>
<column name="MaintLogID1">BRMR35026125</column>
</row>
<row>
<column name="Notes">Boiler Shut down and opened up for inspection.
On applying air test to attemporator one tube was found to have failed (top
row, mid length)
Doosan Babcock SGM attended the vessel on passage to singapore and repairs
were effected.
The damaged tube was cut out approx 100mm each side of failure and the tube
ends plugged and welded.
A support piece was welded in position to support the ends of the cut
tube.
The failure of this tube appears to be from inside which was found to be
badly wasted approx. 25mm downstream
from the butt weld joining the tube.
Deep pitting was also observed on the outside of the tube along a length of
approx 100mm. The adjacent tube was
found to be suffering from the same and from photo it appears some debris
was present trapped between the two tubes.
See photos on T drive /Photo 2007/Stb'd Boiler Attemporator.
The adjacent damaged tube was also cut out and repaired similar to above.
On completion of repairs attemporator was subjected to an air test up to
6.5Bar and soapy water test, pressure
held steady for 10 minutes.
Hand hole door removed from 2nd Stage Superheater to inspect superheater
internals for chemical deposits
possible caused by loss of boiler chemical, internals found spotlessly
clean.
On completion of repairs boiler boxed up using new manhole & hand hole
door joints.</column>
<column name="MaintLogID1">BRMR35026126</column>
</row>
<row>
<column name="Notes">completed during routine PM
maintenance</column>
<column name="MaintLogID1">BRMR35026127</column>
</row>
<row>
<column name="Notes">completed during routine PM
maintenance</column>
<column name="MaintLogID1">BRMR35026128</column>
</row>
<row>
<column name="Notes">All personal electical appliances in all crew
cabins has been checked and passed safe. All identifed by Electrical safety
Tag
signed and dated by ETO</column>
<column name="MaintLogID1">BRMR35026129</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026130</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026131</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026132</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026133</column>
</row>
<row>
<column name="Notes">Completed as per W.O
All in good condition</column>
<column name="MaintLogID1">BRMR35026134</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026138</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026139</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026140</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026141</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026142</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026143</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026144</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026145</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026146</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026147</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026148</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026149</column>
</row>
<row>
<column name="Notes">Completed asper W.O.
All in good order.</column>
<column name="MaintLogID1">BRMR35026150</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All inspected OK.
Insulation readings for fan and compressor > 100 megs
Connections are tight and secure.</column>
<column name="MaintLogID1">BRMR35026151</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All inspected OK.
Insulation readings for fan and compressor > 100 megs
Connections are tight and secure.</column>
<column name="MaintLogID1">BRMR35026152</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All inspected OK.
Insulation readings for fan and compressor > 100 megs
Connections are tight and secure.</column>
<column name="MaintLogID1">BRMR35026153</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All inspected OK.
Insulation readings for fan and compressor > 100 megs
Connections are tight and secure.</column>
<column name="MaintLogID1">BRMR35026154</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All inspected OK.
Insulation readings for fan and compressor > 100 megs
Connections are tight and secure.</column>
<column name="MaintLogID1">BRMR35026155</column>
</row>
<row>
<column name="Notes">Machine running as main machine tested with
electric meter and soapy water
pumped down level ok</column>
<column name="MaintLogID1">BRMR35026170</column>
</row>
<row>
<column name="Notes">ran uop & tested with electric meter and
soapy water
pumped down level ok</column>
<column name="MaintLogID1">BRMR35026171</column>
</row>
<row>
<column name="Notes">Running as main pump valves on condenser
operated</column>
<column name="MaintLogID1">BRMR35026172</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35026173</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35026174</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35026175</column>
</row>
<row>
<column name="Notes"> machines tested with electric meter and soapy
water
</column>
<column name="MaintLogID1">BRMR35026176</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35026177</column>
</row>
<row>
<column name="Notes">Will be carried out once elevator back in
service</column>
<column name="MaintLogID1">BRMR35026178</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026179</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026180</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026181</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026182</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026183</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026184</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026185</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026186</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026187</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026188</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026189</column>
</row>
<row>
<column name="Notes">cleaned & inspected</column>
<column name="MaintLogID1">BRMR35026190</column>
</row>
<row>
<column name="Notes">carried out on unit during changeover</column>
<column name="MaintLogID1">BRMR35026191</column>
</row>
<row>
<column name="Notes">no defects observed fan running fine </column>
<column name="MaintLogID1">BRMR35026192</column>
</row>
<row>
<column name="Notes">System and associated equiptment checked no
defects observed</column>
<column name="MaintLogID1">BRMR35026193</column>
</row>
<row>
<column name="Notes">System pressures all correct no leaks
evident</column>
<column name="MaintLogID1">BRMR35026194</column>
</row>
<row>
<column name="Notes">All checked when boiler shutdown for
maintence</column>
<column name="MaintLogID1">BRMR35026195</column>
</row>
<row>
<column name="Notes">Inspected durin boiler load changes all valves
tight and operating correctly</column>
<column name="MaintLogID1">BRMR35026196</column>
</row>
<row>
<column name="Notes">All realise N2 bottles checked, all the
pressures where ok.
Agitated the dry powder in all 4 of the main deck bottles.
There was a lose flange on the top of number 3 tank, this has been
tightened up and tested.
No spares on board.
New unit ordered and received.
New unit is different type than two others. Received together with battery
charger and spare battery.
No spares on board.
New unit ordered and received.
New unit is different type than two others. Received together with battery
charger and spare battery.
No spares on board.
New unit ordered and received.
New unit is different type than two others. Received together with battery
charger and spare battery.
Note;
This PM was carried out on No2 D/G starting compressor, not the emergency
air compressor as the WO describes.</column>
<column name="MaintLogID1">BRMR35026308</column>
</row>
<row>
<column name="Notes">All satisfactory, Cut in / outs ok - 5.5 - 6.5
kg/cm2.
Compressor Priority
1 3
2 1
3 2</column>
<column name="MaintLogID1">BRMR35026368</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 1
3 2</column>
<column name="MaintLogID1">BRMR35026369</column>
</row>
<row>
<column name="Notes">Completed,
Compressor Priority
1 3
2 1
3 2</column>
<column name="MaintLogID1">BRMR35026370</column>
</row>
<row>
<column name="Notes">Completed, no defects oserved - fully
operational.</column>
<column name="MaintLogID1">BRMR35026371</column>
</row>
<row>
<column name="Notes">Completed, no defects oserved - fully
operational.</column>
<column name="MaintLogID1">BRMR35026372</column>
</row>
<row>
<column name="Notes">Completed, no defects oserved - fully
operational.</column>
<column name="MaintLogID1">BRMR35026373</column>
</row>
<row>
<column name="Notes">All fully operational.</column>
<column name="MaintLogID1">BRMR35026374</column>
</row>
<row>
<column name="Notes">Completed.</column>
<column name="MaintLogID1">BRMR35026375</column>
</row>
<row>
<column name="Notes">C/O No.1 Now lead m/c</column>
<column name="MaintLogID1">BRMR35026376</column>
</row>
<row>
<column name="Notes">C/O No.1 Now lead m/c</column>
<column name="MaintLogID1">BRMR35026377</column>
</row>
<row>
<column name="Notes">C/O No defects observed.</column>
<column name="MaintLogID1">BRMR35026378</column>
</row>
<row>
<column name="Notes">compleated as per routines</column>
<column name="MaintLogID1">BRMR35026379</column>
</row>
<row>
<column name="Notes">Done as part of monthly pm</column>
<column name="MaintLogID1">BRMR35026380</column>
</row>
<row>
<column name="Notes">compleated as per routines</column>
<column name="MaintLogID1">BRMR35026381</column>
</row>
<row>
<column name="Notes">compleated as per routines</column>
<column name="MaintLogID1">BRMR35026382</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35026383</column>
</row>
<row>
<column name="Notes">valves operated pump ran</column>
<column name="MaintLogID1">BRMR35026384</column>
</row>
<row>
<column name="Notes">pumped down,
leak tested with soap and meter</column>
<column name="MaintLogID1">BRMR35026385</column>
</row>
<row>
<column name="Notes">ran leak tested with soap and meter &
pumped down </column>
<column name="MaintLogID1">BRMR35026386</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026387</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.
</column>
<column name="MaintLogID1">BRMR35026388</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026389</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026390</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Bottles charged as required.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026391</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.
All alarms & trips operational.</column>
<column name="MaintLogID1">BRMR35026392</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026402</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026403</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026404</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026405</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026406</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026407</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026408</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026409</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026410</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026411</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026412</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026413</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026414</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026415</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026416</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
All equipment found in good condition.
</column>
<column name="MaintLogID1">BRMR35026418</column>
</row>
<row>
<column name="Notes">All Tested and Satisfactory</column>
<column name="MaintLogID1">BRMR35026419</column>
</row>
<row>
<column name="Notes">All alarms and trips tested
satisfactorily.</column>
<column name="MaintLogID1">BRMR35026420</column>
</row>
<row>
<column name="Notes">No defects observed, all alarms operated ,
piolt bottle weight checked all acceptable</column>
<column name="MaintLogID1">BRMR35026421</column>
</row>
<row>
<column name="Notes">Alarms tested Ok.</column>
<column name="MaintLogID1">BRMR35026422</column>
</row>
<row>
<column name="Notes">Both calls tested Ok.</column>
<column name="MaintLogID1">BRMR35026423</column>
</row>
<row>
<column name="Notes">Checked and found all OK.</column>
<column name="MaintLogID1">BRMR35026424</column>
</row>
<row>
<column name="Notes">Lights switched on for 4 hrs.</column>
<column name="MaintLogID1">BRMR35026425</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Route 1 & 2 tested OK.</column>
<column name="MaintLogID1">BRMR35026426</column>
</row>
<row>
<column name="Notes">Not in use at the moment.</column>
<column name="MaintLogID1">BRMR35026427</column>
</row>
<row>
<column name="Notes">tested OK.</column>
<column name="MaintLogID1">BRMR35026428</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Operational and in good condition.
</column>
<column name="MaintLogID1">BRMR35026429</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Operational and in good condition.
</column>
<column name="MaintLogID1">BRMR35026430</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Operational and in good condition.
</column>
<column name="MaintLogID1">BRMR35026431</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Operational and in good condition.
</column>
<column name="MaintLogID1">BRMR35026432</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist.
Operational and in good condition.
</column>
<column name="MaintLogID1">BRMR35026433</column>
</row>
<row>
<column name="Notes">Outboard handhold door gasket bolt + nut
replaced</column>
<column name="MaintLogID1">BRMR35026434</column>
</row>
<row>
<column name="Notes">Internal of superheater inspected through hand
hold door just as the flow from the attemperator re enters.
inside was very clean no chemical staining</column>
<column name="MaintLogID1">BRMR35026435</column>
</row>
<row>
<column name="Notes">internals of waterdrum& steam drum
inspected no defects abserved
</column>
<column name="MaintLogID1">BRMR35026436</column>
</row>
<row>
<column name="Notes">Oil probes operational</column>
<column name="MaintLogID1">BRMR35026437</column>
</row>
<row>
<column name="Notes">CO2 cartr5idge in N 50 extingusher replaced
( weight-1950g - half empty, should be 2200g when full)
seal for N46 ext. replaced.</column>
<column name="MaintLogID1">BRMR35026439</column>
</row>
<row>
<column name="Notes">Roller Fairlead for Port Aft M'Deck
Springs, scaled.
Remaining Fairleads greased.</column>
<column name="MaintLogID1">BRMR35026445</column>
</row>
<row>
<column name="Notes">All alarms and trips fully operational.
No problems observed.</column>
<column name="MaintLogID1">BRMR35026446</column>
</row>
<row>
<column name="Notes">No.2 LO purifier ran on D/G sump with no
leakage observed.
Purifier fully operational.</column>
<column name="MaintLogID1">BRMR35026447</column>
</row>
<row>
<column name="Notes">Pump inspected whilst transferring from DO
storgage tk to MGO storage tk, no problems observed.
Air inlet control soleniod valve was sticking about 20% open when it should
have been closed. The valve
was removed, opened up, cleaned and reasembled. The problem was that with
the soleniod springs. Both
springs had started to corrode leaving rust particals jaming up the
soleniod's pistons preventing them from
opening fully. Valve was tested on completion all was in good working
order.
Pressure stats.
The units where not cutting in or out correctly. Both units would hunt at
the upper cut out range. Which increased
the running hours on the units. Both stats where removed and set up
correctly.
The change over switch now operates as follows.
Position 1
PS-2A operates No.1 N2 plant ( back up )
PS-2B operates No.2 N2 plant ( master )
Position 2
PS-2A operates No.2 plant ( back up )
PS-2B operates No.1 plant ( master )
Didn't smell too bad and clear water found at top of clarification
chamber.
NOTE:
The vacuumarator cooling line has been changed onto the second stage
aeration chamber to try and keep it clear for longer.</column>
<column name="MaintLogID1">BRMR35026463</column>
</row>
<row>
<column name="Notes">All stbd boiler igniters removed and tips
soaked in carbon remover.
No.1 & No.2 found to be clean and excess carbon scraped off.
No.3 found clogged up, this was removed after a prolonged period in carbon
clean.
1. 14.8
2. 16.1
3. 15.1</column>
<column name="MaintLogID1">BRMR35026464</column>
</row>
<row>
<column name="Notes">All Port boiler igniters removed and tips
soaked in carbon remover.
No.1 & No.3 found to be clean and excess carbon scraped off.
No.2 found not lighting off burners, this was because the elemnt had come
away in a mass of carbon.
Tip was replaced and tested - fully operational.
Resistances measured after igniters back at boiler temp (ohms);
1. 16.4
2. 14.8
3. 15.8</column>
<column name="MaintLogID1">BRMR35026465</column>
</row>
<row>
<column name="Notes">Greased as per PM</column>
<column name="MaintLogID1">BRMR35026466</column>
</row>
<row>
<column name="Notes">Greased as per PM.
Clutch in need of attention after jumping - C/E on the case.
Cable counter scaled and re-painted.
</column>
<column name="MaintLogID1">BRMR35026467</column>
</row>
<row>
<column name="Notes">Greased as per PM.
Cable Counter scaled and re-painted.</column>
<column name="MaintLogID1">BRMR35026468</column>
</row>
<row>
<column name="Notes">Two Eyepads replaced.</column>
<column name="MaintLogID1">BRMR35026469</column>
</row>
<row>
<column name="Notes">Flock removed normal amount
New anode fitted to cnl 5
Discharge valve frim middle tank seat failed so removed
Vent found blocked on this tank </column>
<column name="MaintLogID1">BRMR35026470</column>
</row>
<row>
<column name="Notes">Flock removed normal amount
New anode fitted to cnl 5
Discharge valve frim middle tank seat failed so removed
Vent found blocked on this tank </column>
<column name="MaintLogID1">BRMR35026471</column>
</row>
<row>
<column name="Notes">Furnace inspected no defects to note other
than the condition of the burner surrounds that were recorded last dry dock
Very little debrie found in bottom all tubes ans refactory look in good
condition</column>
<column name="MaintLogID1">BRMR35026472</column>
</row>
<row>
<column name="Notes">Coupling inspected found to be in very good
condition.</column>
<column name="MaintLogID1">BRMR35026473</column>
</row>
<row>
<column name="Notes">Samples collected as listed in PM</column>
<column name="MaintLogID1">BRMR35026474</column>
</row>
<row>
<column name="Notes">All gauges removed from port and stb side
manifolds tested on budenburg,
All gauges within acceptable limits.
IH
</column>
<column name="MaintLogID1">BRMR35026475</column>
</row>
<row>
<column name="Notes">Fans inspected no external corrosion, no
abnormal vibration or noise
all in good order.
IM</column>
<column name="MaintLogID1">BRMR35026476</column>
</row>
<row>
<column name="Notes">Fans inspected no external corrosion, no
abnormal vibration or noise
all in good order.
IM</column>
<column name="MaintLogID1">BRMR35026477</column>
</row>
<row>
<column name="Notes">Completed
All prodes reading ok. Pockets tight.
silicone grease applied to o rings.</column>
<column name="MaintLogID1">BRMR35026478</column>
</row>
<row>
<column name="Notes">Completed as per pm.
Hoses not replaced this time as all in good condition.</column>
<column name="MaintLogID1">BRMR35026479</column>
</row>
<row>
<column name="Notes">completed as per routine, readings compare
well, slight rolling of vessel</column>
<column name="MaintLogID1">BRMR35026480</column>
</row>
<row>
<column name="Notes">completed as per routine, all alarms operated
correctly</column>
<column name="MaintLogID1">BRMR35026481</column>
</row>
<row>
<column name="Notes">Alarms & trips tested - OK ( for operation
on MDO).</column>
<column name="MaintLogID1">BRMR35026482</column>
</row>
<row>
<column name="Notes">Refractory & fan V-belts found in good
condition, burner nozzles & swirl plate cleaned, spark arrester
cleaned.</column>
<column name="MaintLogID1">BRMR35026483</column>
</row>
<row>
<column name="Notes">No fastenings found loose and no corrosion
found.
Fabric not showing signs of breaking down or exposing rust spots</column>
<column name="MaintLogID1">BRMR35026485</column>
</row>
<row>
<column name="Notes">Heater not cleaned at this time as it has only
been in service for just over 2 month
All valves inspected and found tight.
ooperation was abserved when running full fuel no problems
encountered</column>
<column name="MaintLogID1">BRMR35026486</column>
</row>
<row>
<column name="Notes">All alarms and trips fully operational.
Cutting in at 10.0 bar and out at 12.0 bar
</column>
<column name="MaintLogID1">BRMR35026491</column>
</row>
<row>
<column name="Notes">Wire in Satisfactory condition. Due for
renewal in 2008.
Port Top Turntable in need of fabric maintenance - will be done when Port
Maindeck undertaken.
Ladder greased as per monthly PM's.</column>
<column name="MaintLogID1">BRMR35026492</column>
</row>
<row>
<column name="Notes">Slip ring cleaned.
This has to be replaced in next dock anyway.
results:
charger ON:
1 2.18
2 2.18
3 2.17
4 2.17
5 2.18
6 2.18
7 2.18
8 2.18
9 2.18
10 2.17
11 2.18
12 2.18
total 26.21V
after 2 hrs:
1 2.06
2 2.06
3 2.05
4 2.06
5 2.05
6 2.06
7 2.06
8 2.06
9 2.06
10 2.06
11 2.05
12 2.06
total : 24,78V
NOTE: readings for both of them are not very same when speed > than 15
knots.
Problem probably lies in position of transducers. They are fitted nearly
next to eachother. ( about 1,5 meters)
Any current or turbulence of water makes second log (aft facing) read 2-4
knots more sometimes. BAD DESIGN!
</column>
<column name="MaintLogID1">BRMR35026528</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Float charge:
1 2.26
2 2.33
3 2.38
4 2.32
5 2.26
6 2.26
7 2.28
8 2.33
9 2.26
10 2.28
11 2.28
12 2.29
total 27,45V</column>
<column name="MaintLogID1">BRMR35026529</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
em'cy gen batteries.
GOVERNOR:
float voltage:
Batt.1 13,05
Batt.2 13,07
Batt.1 12,57
Batt.2 12,60
temp. 48 deg C
phase bridge -1 to 1 mV
current 257 mA
temp. 49 deg C
phase bridge -2 to 2 mV
current 245 mA
</column>
<column name="MaintLogID1">BRMR35026597</column>
</row>
<row>
<column name="Notes">Correctly stowed, all bolts present and
greased. Boxes watertight.</column>
<column name="MaintLogID1">BRMR35026598</column>
</row>
<row>
<column name="Notes">In good condition. Correctly stowed. All gear
present.</column>
<column name="MaintLogID1">BRMR35026599</column>
</row>
<row>
<column name="Notes">Replaced 3/E, Worker 106 and Electrical
Workshop.
</column>
<column name="MaintLogID1">BRMR35026695</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Both alarms tested Ok.</column>
<column name="MaintLogID1">BRMR35026696</column>
</row>
<row>
<column name="Notes">Completewd as per Pm.
All working OK.</column>
<column name="MaintLogID1">BRMR35026697</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Lights on for 4 hrs.
Insulation OK.</column>
<column name="MaintLogID1">BRMR35026698</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Route 3&4 tested Ok</column>
<column name="MaintLogID1">BRMR35026699</column>
</row>
<row>
<column name="Notes">Not in use</column>
<column name="MaintLogID1">BRMR35026700</column>
</row>
<row>
<column name="Notes">DSC tested OK.</column>
<column name="MaintLogID1">BRMR35026701</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35026702</column>
</row>
<row>
<column name="Notes">leak tested</column>
<column name="MaintLogID1">BRMR35026703</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35026704</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35026705</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35026706</column>
</row>
<row>
<column name="Notes">ran aux condenser</column>
<column name="MaintLogID1">BRMR35026707</column>
</row>
<row>
<column name="Notes">pumped down leak tested meter and gas</column>
<column name="MaintLogID1">BRMR35026708</column>
</row>
<row>
<column name="Notes">leak tested pumped down </column>
<column name="MaintLogID1">BRMR35026709</column>
</row>
<row>
<column name="Notes">no evidence of cracks
damage to the deck head coating is the same as when tank was last inspected
1 u bolt holding sounding pipe sheared needed to be replaced
tank side and bottom coating looks good</column>
<column name="MaintLogID1">BRMR35026710</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35026711</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35026712</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35026713</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35026714</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35026715</column>
</row>
<row>
<column name="Notes">completed as per part of weekly
routines.</column>
<column name="MaintLogID1">BRMR35026716</column>
</row>
<row>
<column name="Notes">Smoke indicators inspected and cleaned all in
good order,</column>
<column name="MaintLogID1">BRMR35026717</column>
</row>
<row>
<column name="Notes">Smoke indicators inspected and cleaned all in
good order,</column>
<column name="MaintLogID1">BRMR35026718</column>
</row>
<row>
<column name="Notes">Done as per part of routines. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35026719</column>
</row>
<row>
<column name="Notes">Done as per part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026720</column>
</row>
<row>
<column name="Notes">Done as per part of weekly routines</column>
<column name="MaintLogID1">BRMR35026721</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System fully operational.
</column>
<column name="MaintLogID1">BRMR35026722</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Units in satisfactory condition.
To test them socket pins have to been pushed in far inside to get proper
resistance readings.
found different labels on the cables from 3C solenoid box. this will be
checked and corrected if they are wrongly marked.
</column>
<column name="MaintLogID1">BRMR35026736</column>
</row>
<row>
<column name="Notes">tested all alarms OK.</column>
<column name="MaintLogID1">BRMR35026737</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All alarms and trips operational.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026738</column>
</row>
<row>
<column name="Notes">All alarms tested ok.
Unable to test trips as machine not in service due to loss of trip valve.
All trips to be tested when new trip valve is fitted.</column>
<column name="MaintLogID1">BRMR35026739</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All trips and alarms operational.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026740</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
System fully operational.
Tested OK</column>
<column name="MaintLogID1">BRMR35026741</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
System fully operational.
Tested OK</column>
<column name="MaintLogID1">BRMR35026742</column>
</row>
<row>
<column name="Notes">Antennas inspected - all satisfactory.
Distribution boxes checked and found all Ok.
Connections tight.</column>
<column name="MaintLogID1">BRMR35026743</column>
</row>
<row>
<column name="Notes">System working satisfactory.</column>
<column name="MaintLogID1">BRMR35026744</column>
</row>
<row>
<column name="Notes">All spaces ok. Bilge alarms tested
satis.</column>
<column name="MaintLogID1">BRMR35026745</column>
</row>
<row>
<column name="Notes">All spaces ok. bilge alarms tested
satis</column>
<column name="MaintLogID1">BRMR35026746</column>
</row>
<row>
<column name="Notes">all isolators operated and greased. all
satis</column>
<column name="MaintLogID1">BRMR35026747</column>
</row>
<row>
<column name="Notes">hoses tested as per week 3. all satis</column>
<column name="MaintLogID1">BRMR35026748</column>
</row>
<row>
<column name="Notes">hoses tested as per week 3. all satis</column>
<column name="MaintLogID1">BRMR35026749</column>
</row>
<row>
<column name="Notes">Port lifeboat lowered to water. Water spray
test did not operate due to valve seized. This was freed up after recovery.
Boat was run for 20mins in water. All satis.
Whilst stowing the boat the fwd gripe got caught between the jaws on the
davit head and the fall block.
This bent the rounded part of the jaws , resulting in the gap not allowing
the lugs on the fall wire to fit.
This was rectified by restoring the original gap on the jaws using a
hydraulic jack to open it up..</column>
<column name="MaintLogID1">BRMR35026750</column>
</row>
<row>
<column name="Notes">Boat lowered to water and run on test for
approx 20mins. water spray tested satis.
Boat was launched , tested and recovered without incident.</column>
<column name="MaintLogID1">BRMR35026751</column>
</row>
<row>
<column name="Notes">accomodation ladder air motor tested ok.
Lubricators topped up.
all satis</column>
<column name="MaintLogID1">BRMR35026752</column>
</row>
<row>
<column name="Notes">accomodation air motor tested ok. lubricators
topped up
all satis</column>
<column name="MaintLogID1">BRMR35026753</column>
</row>
<row>
<column name="Notes">All tested and satisfactory
callibrated</column>
<column name="MaintLogID1">BRMR35026754</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35026755</column>
</row>
<row>
<column name="Notes">All Satisafctory</column>
<column name="MaintLogID1">BRMR35026756</column>
</row>
<row>
<column name="Notes">filter diff checked ok
this filter was replaced 3 month ago</column>
<column name="MaintLogID1">BRMR35026757</column>
</row>
<row>
<column name="Notes">Pump observed when running no defects
Entec results are coming back satisfactory for this unit</column>
<column name="MaintLogID1">BRMR35026758</column>
</row>
<row>
<column name="Notes">Fwd drum relief valve gasket changed
furnace inspected 3 bags of loose debrie removed
burner quals is same condition as previously reported</column>
<column name="MaintLogID1">BRMR35026759</column>
</row>
<row>
<column name="Notes">All Statisfactory</column>
<column name="MaintLogID1">BRMR35026760</column>
</row>
<row>
<column name="Notes">Both endcovers on this fan have been replaced
last month, the correct spare parts are on order
at the moment fan runs a little noisy amps 4 </column>
<column name="MaintLogID1">BRMR35026761</column>
</row>
<row>
<column name="Notes">All sample points checked except the cofferdam
spaces which will be completed during
cofferdam inspections.
The only faults found where No 2 and 3 vent mast connections where the
wrong way around in the panel.
The other fault was the compression fittings where lose on the cargo
machinery room aft.
The tripping of the LD was not completed because this was tested on the
23/05/07.
Both pumps where o/h'd on late last month, with new diaphragm's
fitted.</column>
<column name="MaintLogID1">BRMR35026762</column>
</row>
<row>
<column name="Notes">All exposed bolts hammer tested. All
ok.</column>
<column name="MaintLogID1">BRMR35026763</column>
</row>
<row>
<column name="Notes">All exposed bolts hammer tested. All
ok.</column>
<column name="MaintLogID1">BRMR35026764</column>
</row>
<row>
<column name="Notes">All exposed bolts hammer tested. All
ok.</column>
<column name="MaintLogID1">BRMR35026765</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35026766</column>
</row>
<row>
<column name="Notes">Done with the 12 mounthly pm</column>
<column name="MaintLogID1">BRMR35026767</column>
</row>
<row>
<column name="Notes">Punp inspected when running no defects
observed,
</column>
<column name="MaintLogID1">BRMR35026768</column>
</row>
<row>
<column name="Notes">Fwd drum relief valve gasket changed
furnace inspected 3 bags of loose debrie removed
burner quals is same condition as previously reported</column>
<column name="MaintLogID1">BRMR35026769</column>
</row>
<row>
<column name="Notes">Completed as per PM.
A -deck alleyway battery did not pass test.
</column>
<column name="MaintLogID1">BRMR35026810</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026811</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026812</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026813</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026814</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026815</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026816</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026817</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026818</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026819</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026820</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026821</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026822</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026823</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026824</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026825</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026826</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026827</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35026828</column>
</row>
<row>
<column name="Notes">Boilers on Gas Mode. Cleaning of filter not
necessary.</column>
<column name="MaintLogID1">BRMR35026829</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026830</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026831</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026832</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026833</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026834</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026835</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026836</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026837</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026838</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026839</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026840</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026841</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026842</column>
</row>
<row>
<column name="Notes">done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026843</column>
</row>
<row>
<column name="Notes">spaces inspected , bilge alarms tested
satis</column>
<column name="MaintLogID1">BRMR35026844</column>
</row>
<row>
<column name="Notes">spaces inspected , bilge alarms tested
satis</column>
<column name="MaintLogID1">BRMR35026845</column>
</row>
<row>
<column name="Notes">both resuscepacs checked .
This is the same failure as No.2 T/Alt and most probable cause is chemical
carry oveer from Stb'd boiler damaged attemporator
during April/May.</column>
<column name="MaintLogID1">BRMR35026848</column>
</row>
<row>
<column name="Notes">On testing of Emerg'y trip valve it
failed to close. On investigation it was found that spindle was seized in
bush.
Valve assembly removed from m/c and landed to Dubai Drydocks where the
spindle was pressed out. Spindle & bush
were polished. Valve assy was returned to the vessel and refitted. Trip
functiion was tested and proved operational.
This is the same fault as No.2 T/Alt, most likely cause thought to be
chemical carryover from stb'd boiler whilst running with
a damaged attemperator (holed tube) during April/May.</column>
<column name="MaintLogID1">BRMR35026849</column>
</row>
<row>
<column name="Notes">During routine testing of alarms and trips it
was found that emergency valve was not closing.
Valve removed and examined, spindle found seized in cover bush. Unit landed
to Dubai Drydocks where
spindle was pressed out. Bush and spindle cleaned and polished, returned to
vessel and reassembled.
Unit run on test and trip function proved to operate normally.
Same fault as found with No.2 T/Alt, probable cause put down to chemical
carry over from damaged attemperator on stb'd boiler
(holed tube) during April/May.</column>
<column name="MaintLogID1">BRMR35026850</column>
</row>
<row>
<column name="Notes">Compressor's air discharge high
temperature trip functional.
Auto cut in at 24.89 bar, lag cut in at 22.9 bar, both stop at 29.91 bar.
L.P. and H.P. safety valves removed and bench tested. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35026851</column>
</row>
<row>
<column name="Notes">Compressor's air discharge high
temperature trip functional.
Auto cut in at 24.8 bar, lag cut in at 22.8 bar, both stop at 29.9 bar.
L.P. and H.P. safety valves removed and bench tested. All satisfactory.
</column>
<column name="MaintLogID1">BRMR35026852</column>
</row>
<row>
<column name="Notes">Reserve pressure checked at 0.7 MPa.</column>
<column name="MaintLogID1">BRMR35026853</column>
</row>
<row>
<column name="Notes">Reserve pressure checked at 0.9 MPa.</column>
<column name="MaintLogID1">BRMR35026854</column>
</row>
<row>
<column name="Notes">valve lid removed, the cause of backflow
problems was a build up of salt on valve plug guide.
valve cleaned lapped and back in service</column>
<column name="MaintLogID1">BRMR35026855</column>
</row>
<row>
<column name="Notes">Pump performance is satisfactory, entec
results are good.
mechanical seal tight
coupling bolts and rubbers satisfactory
all holding down arangements satisfactory</column>
<column name="MaintLogID1">BRMR35026856</column>
</row>
<row>
<column name="Notes">Pump performance is satisfactory, entec
results are good.
mechanical seal tight
coupling bolts and rubbers satisfactory
all holding down arangements satisfactory</column>
<column name="MaintLogID1">BRMR35026857</column>
</row>
<row>
<column name="Notes">Pump performance is satisfactory, entec
results are good.
mechanical seal tight
coupling bolts and rubbers satisfactory
all holding down arangements satisfactory</column>
<column name="MaintLogID1">BRMR35026858</column>
</row>
<row>
<column name="Notes">All internal dampers operated and
reset</column>
<column name="MaintLogID1">BRMR35026859</column>
</row>
<row>
<column name="Notes">all glands checked
security of micro switches
solinoid racks inspected</column>
<column name="MaintLogID1">BRMR35026860</column>
</row>
<row>
<column name="Notes">glands checked ,micro switches checked, no
defects</column>
<column name="MaintLogID1">BRMR35026861</column>
</row>
<row>
<column name="Notes">3 levers set off for lloyds on 20 th june.
independant valves and alarn ok</column>
<column name="MaintLogID1">BRMR35026862</column>
</row>
<row>
<column name="Notes">cleaned and frames repainted</column>
<column name="MaintLogID1">BRMR35026863</column>
</row>
<row>
<column name="Notes">cleaned and frames repainted</column>
<column name="MaintLogID1">BRMR35026864</column>
</row>
<row>
<column name="Notes">Fan inspected as per PM.
No abnormal noise or vibrations observed.
All fastenings secured.
</column>
<column name="MaintLogID1">BRMR35026865</column>
</row>
<row>
<column name="Notes">Fan inspected as per work order.
No abnormalities observed.
</column>
<column name="MaintLogID1">BRMR35026866</column>
</row>
<row>
<column name="Notes">Pump in good condition.
No leakage observed.
Pressures within limits.
No abnormal noise or vibrations observed.
</column>
<column name="MaintLogID1">BRMR35026873</column>
</row>
<row>
<column name="Notes">Points lubricated fan visually
inspected</column>
<column name="MaintLogID1">BRMR35026874</column>
</row>
<row>
<column name="Notes">Points lubricated fan visually
inspected</column>
<column name="MaintLogID1">BRMR35026875</column>
</row>
<row>
<column name="Notes">21 extinguishers checked as per PM. Details in
computer T:/Engineering Department/JE/Fire equipment &
Dampers/2007</column>
<column name="MaintLogID1">BRMR35026876</column>
</row>
<row>
<column name="Notes">Completed, oil probes OK.</column>
<column name="MaintLogID1">BRMR35026877</column>
</row>
<row>
<column name="Notes">all ok</column>
<column name="MaintLogID1">BRMR35026878</column>
</row>
<row>
<column name="Notes">Carried out as part of WO MER/06/06469
coupling inspection
which is also a 12 monthy PM.
</column>
<column name="MaintLogID1">BRMR35026885</column>
</row>
<row>
<column name="Notes">Reported bridge wing gyro repeater not
operational.
Found defective step motor, unable to move motor and synchronise with
master gyro.
New unit fitted and synchronised with master gyro with no problem.
</column>
<column name="MaintLogID1">BRMR35026886</column>
</row>
<row>
<column name="Notes">SART's tested Ok.
All logged in GMDSS log book.</column>
<column name="MaintLogID1">BRMR35026887</column>
</row>
<row>
<column name="Notes">All three units tested Ok.
One unit received lately (different type) but compatible with our
system.</column>
<column name="MaintLogID1">BRMR35026888</column>
</row>
<row>
<column name="Notes">All three units tested Ok.
One unit received lately (different type) but compatible with our
system.</column>
<column name="MaintLogID1">BRMR35026889</column>
</row>
<row>
<column name="Notes">All three units tested Ok.
One unit received lately (different type) but compatible with our
system.</column>
<column name="MaintLogID1">BRMR35026890</column>
</row>
<row>
<column name="Notes">Completed as per PM.
EPIRB tested Ok.
All logged into GMDSS log book.</column>
<column name="MaintLogID1">BRMR35026891</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026892</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026893</column>
</row>
<row>
<column name="Notes">system inspected no defects</column>
<column name="MaintLogID1">BRMR35026894</column>
</row>
<row>
<column name="Notes">All lines inspectes gas torch inspected back
flow checked</column>
<column name="MaintLogID1">BRMR35026895</column>
</row>
<row>
<column name="Notes">cleaned</column>
<column name="MaintLogID1">BRMR35026896</column>
</row>
<row>
<column name="Notes">unit cleaned tested all electrical conections
checked</column>
<column name="MaintLogID1">BRMR35026897</column>
</row>
<row>
<column name="Notes">unit cleaned tested all electrical conections
checked</column>
<column name="MaintLogID1">BRMR35026898</column>
</row>
<row>
<column name="Notes">cleaned</column>
<column name="MaintLogID1">BRMR35026899</column>
</row>
<row>
<column name="Notes">filter cleaned</column>
<column name="MaintLogID1">BRMR35026900</column>
</row>
<row>
<column name="Notes">Evaporators cleaned</column>
<column name="MaintLogID1">BRMR35026901</column>
</row>
<row>
<column name="Notes">Evaporators cleaned</column>
<column name="MaintLogID1">BRMR35026902</column>
</row>
<row>
<column name="Notes">All anodes inspected all in good condition
condenser nice and clean inside coatings look good</column>
<column name="MaintLogID1">BRMR35026903</column>
</row>
<row>
<column name="Notes">Fan in good condition</column>
<column name="MaintLogID1">BRMR35026904</column>
</row>
<row>
<column name="Notes">Fan in good condition</column>
<column name="MaintLogID1">BRMR35026905</column>
</row>
<row>
<column name="Notes">Belts in good condition
sensing lines clear</column>
<column name="MaintLogID1">BRMR35026906</column>
</row>
<row>
<column name="Notes">Found in good condition grease
renewed</column>
<column name="MaintLogID1">BRMR35026907</column>
</row>
<row>
<column name="Notes">Valve sealing faces and non return valve
inspected
both free to operate</column>
<column name="MaintLogID1">BRMR35026908</column>
</row>
<row>
<column name="Notes">Both remote bilge valves opened up for
inspection.
Valves internals found to be in good condition.
Valves boxed up and tested. All in good working order and fully
operational.
</column>
<column name="MaintLogID1">BRMR35026909</column>
</row>
<row>
<column name="Notes">Calorifier on electric heating elements all
the time.
No leaks from safety valve observed.
Pressure gauge and thermometer intact and reading correctly.
</column>
<column name="MaintLogID1">BRMR35026910</column>
</row>
<row>
<column name="Notes">All valves on air receivers fully operational.
</column>
<column name="MaintLogID1">BRMR35026911</column>
</row>
<row>
<column name="Notes">Propeller painted with intersllek, therefore
scrubbing not required.
Prop examined 4/12/06 during hull cleaning ops at Point Fortin, Trinidad.
Paint in good condition no fouling</column>
<column name="MaintLogID1">BRMR35026912</column>
</row>
<row>
<column name="Notes">Tank inspected by 2/E and C/O
Coatings itntact.
No cracking or structural deformation observed.
All fixtures secure.
Some rust rash observed along weld of connection between tank ceiling and
outboard side. Probably present from new.
Tank was clean apart from small puddle in lower corner</column>
<column name="MaintLogID1">BRMR35026913</column>
</row>
<row>
<column name="Notes">All isolators operated and greased
satis</column>
<column name="MaintLogID1">BRMR35026914</column>
</row>
<row>
<column name="Notes">Hose tests carried out as per wk 4
schedule</column>
<column name="MaintLogID1">BRMR35026915</column>
</row>
<row>
<column name="Notes">Hose tests carried out as per wk 4
schedule</column>
<column name="MaintLogID1">BRMR35026916</column>
</row>
<row>
<column name="Notes">Three new speakers received.
Two speakers fitted to the AFT system AFT facing ones.
</column>
<column name="MaintLogID1">BRMR35026943</column>
</row>
<row>
<column name="Notes">Motor bearings greased.
</column>
<column name="MaintLogID1">BRMR35026944</column>
</row>
<row>
<column name="Notes">Flag indicator was defective, bent spindle.
Renewed spindle and cover with ships spare. The parts where not listed in
amos, but I have ordered new bits so that we can
make up a complete assembly.
There was alot of moisture within the box, so i've ordered up
additional lip seals, o-rings so that the remaining flag indicators can be
overhauled. </column>
<column name="MaintLogID1">BRMR35026945</column>
</row>
<row>
<column name="Notes">O2 meter calibrated, all in good order.
Comppressor and frean levels are ok, no sign of any leakage.</column>
<column name="MaintLogID1">BRMR35026946</column>
</row>
<row>
<column name="Notes">All alarms and trips tested. All where at the
correct set points. Except the buffer tank alarms which are set to
Low pressure: 175Kpa
High pressure: 680Kpa</column>
<column name="MaintLogID1">BRMR35026947</column>
</row>
<row>
<column name="Notes">No leakage's.
Differential pressure ok.</column>
<column name="MaintLogID1">BRMR35026948</column>
</row>
<row>
<column name="Notes">No leakage's.
Differential pressure ok.</column>
<column name="MaintLogID1">BRMR35026949</column>
</row>
<row>
<column name="Notes">All in good order.
O2- 1.63%</column>
<column name="MaintLogID1">BRMR35026950</column>
</row>
<row>
<column name="Notes">All in good order.
O2 - 1.74%</column>
<column name="MaintLogID1">BRMR35026951</column>
</row>
<row>
<column name="Notes">All valves operated, no problems with any of
them.</column>
<column name="MaintLogID1">BRMR35026952</column>
</row>
<row>
<column name="Notes">This pump requires a new coupling cover,
because the one in use is cracked. One is now on order and a defect
has been set up for this pump. Because of this it should only be used as
the 2nd back up.
The coupling itself is in good condition. It's been cleaned up
inspected and new grease applied.
Pump tested on completion all was running smoothly.
Pump RH- 2674
</column>
<column name="MaintLogID1">BRMR35026953</column>
</row>
<row>
<column name="Notes">Fan was opened up for inspection due to
abnornal noises while running.
The defect was found to be from the blades touching on the brass wear ring
that was fitted. What happened was the
wear ring was getting pushed inwards towards the impeller by corrosion
behind it.
The wear ring was removed and the fan casing has been chipped, scaled and
painted. The wear ring was not refitted due to having no brass onboard.
The fan motor was overhauled and new bearings and lip seals fitted.
On completion the fan was tested, all in good order.
Running Amps - 4.6Amp
The parts required to overhaul this type of motor are
2 of 6206-ZZ bearings
2 of 30 x 40 x 7mm Lip seals. </column>
<column name="MaintLogID1">BRMR35026954</column>
</row>
<row>
<column name="Notes">No abnormal noise or vibs.
PM completed along with MER/06/90046</column>
<column name="MaintLogID1">BRMR35026955</column>
</row>
<row>
<column name="Notes">Coupling and chain are in good condition.
Both the motor and pump where free to turn.
Coupling cleaned up, inspected and new grease applied.
Running hours - 3226</column>
<column name="MaintLogID1">BRMR35026956</column>
</row>
<row>
<column name="Notes">Both the coupling and chain where in good
condition.
Motor and pump where both free to turn.
Couping was cleaned up, inspected and new grease applied.
Running hours - 4785
Note this unit is to be used as the master unit, until the defect on No.1
pump coupling is fixed.</column>
<column name="MaintLogID1">BRMR35026957</column>
</row>
<row>
<column name="Notes">Pump casing opened up due to a leaky casing.
Pump was in gerneral in good condition, the only small defect on it is that
some of the locating pins on the wear rings are no longer present.
We had problems trying to reseal the mechanical seal gasket due to a small
misalinement between the casing and the cover. Because of this we had to
fit a
slighty thicker gasket to try and take up the alinement
Both the motor and the pump where free to turn. </column>
<column name="MaintLogID1">BRMR35026958</column>
</row>
<row>
<column name="Notes">Dryer inspected.
Residual pressure still acceptable.
Moisture indicator green.
Differential pressures within limits.
Condensate drain ok.
</column>
<column name="MaintLogID1">BRMR35026959</column>
</row>
<row>
<column name="Notes">Dryer inspected.
Change over sequence operational.
Residual pressure acceptable.
Moisture indicator green.
Differential pressures within limits.
Condensate drain ok.
</column>
<column name="MaintLogID1">BRMR35026960</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.
Units were all inspected by shore side last month.
One unit with leaking whistle was send ashore to be repaired.
Unit now back onboard.</column>
<column name="MaintLogID1">BRMR35026961</column>
</row>
<row>
<column name="Notes">completed as per pm.</column>
<column name="MaintLogID1">BRMR35026962</column>
</row>
<row>
<column name="Notes">Pump covered by vibration monitoring. All
readings are good.
Discharge pressure good. Visual inspection carried out.
No defects to report.
Unit not overhauled this time.</column>
<column name="MaintLogID1">BRMR35026963</column>
</row>
<row>
<column name="Notes">completed as per pm.
</column>
<column name="MaintLogID1">BRMR35026982</column>
</row>
<row>
<column name="Notes">Completed as per PM
Unit in good condition
Tested and in good operational order
</column>
<column name="MaintLogID1">BRMR35026983</column>
</row>
<row>
<column name="Notes">Cooler flushed at the end of June.
</column>
<column name="MaintLogID1">BRMR35026984</column>
</row>
<row>
<column name="Notes">Completed as per pm.
All trips operating satisfactorily.
No defects to report.</column>
<column name="MaintLogID1">BRMR35026985</column>
</row>
<row>
<column name="Notes">Oil, HP alarms tested Lp cut out observed
operation of unloader checked on both units.
oil 1.6 at 0.9 lp
lp 0.3
hp 21.5</column>
<column name="MaintLogID1">BRMR35026986</column>
</row>
<row>
<column name="Notes">Both condensers checked from fwd end no
defects observed</column>
<column name="MaintLogID1">BRMR35026987</column>
</row>
<row>
<column name="Notes">both units cleaned down and leak tested
fan covers removed and fans inspected
All fittings on system checked for correct operation and tightness
safety valves vent pipe removed and leek tester observer for 10 min when
unit going through its usual run</column>
<column name="MaintLogID1">BRMR35026988</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned speayed with mild clorine solution.
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026989</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned speayed with mild clorine solution.
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026990</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned speayed with mild clorine solution.
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35026991</column>
</row>
<row>
<column name="Notes">Filter inspected
unit calibrated as per the instruction manual</column>
<column name="MaintLogID1">BRMR35026992</column>
</row>
<row>
<column name="Notes">Not necessary at the moment both boilers on
gas only.</column>
<column name="MaintLogID1">BRMR35026993</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026994</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026995</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026996</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026997</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026998</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35026999</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027000</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027001</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027002</column>
</row>
<row>
<column name="Notes">No abnormal noises or vibs.</column>
<column name="MaintLogID1">BRMR35027003</column>
</row>
<row>
<column name="Notes">No abnormal noises or vibs.</column>
<column name="MaintLogID1">BRMR35027004</column>
</row>
<row>
<column name="Notes">No abnormal noises or vibs.</column>
<column name="MaintLogID1">BRMR35027005</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027006</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027007</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027008</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027009</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027010</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027011</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027012</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027013</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027014</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027015</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027016</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027017</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027018</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027019</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027020</column>
</row>
<row>
<column name="Notes">Completed as per WO</column>
<column name="MaintLogID1">BRMR35027021</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027022</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Started with spring starter.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027023</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Started on local panel.
No defcts to report.</column>
<column name="MaintLogID1">BRMR35027024</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027025</column>
</row>
<row>
<column name="Notes">Vacuum pump rotates stiffly by hand.</column>
<column name="MaintLogID1">BRMR35027026</column>
</row>
<row>
<column name="Notes">all ok</column>
<column name="MaintLogID1">BRMR35027035</column>
</row>
<row>
<column name="Notes">greased and inspected</column>
<column name="MaintLogID1">BRMR35027036</column>
</row>
<row>
<column name="Notes">greased</column>
<column name="MaintLogID1">BRMR35027037</column>
</row>
<row>
<column name="Notes">greased</column>
<column name="MaintLogID1">BRMR35027038</column>
</row>
<row>
<column name="Notes">[NULL]</column>
<column name="MaintLogID1">BRMR35027039</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35027040</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35027041</column>
</row>
<row>
<column name="Notes">Ran on aux condenser all valves
operated</column>
<column name="MaintLogID1">BRMR35027042</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027043</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35027044</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027045</column>
</row>
<row>
<column name="Notes">operation observed
leak test electric and soap</column>
<column name="MaintLogID1">BRMR35027046</column>
</row>
<row>
<column name="Notes">operation observed unit pumped down
leak test electric and soap</column>
<column name="MaintLogID1">BRMR35027047</column>
</row>
<row>
<column name="Notes">operation observed unit pumped down
leak test electric and soap</column>
<column name="MaintLogID1">BRMR35027048</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027049</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027050</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027051</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027052</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027053</column>
</row>
<row>
<column name="Notes">All vent masts drained. all satis</column>
<column name="MaintLogID1">BRMR35027054</column>
</row>
<row>
<column name="Notes">eye wash staions inspected . One bottle found
open in ECR . Replaced with spare
</column>
<column name="MaintLogID1">BRMR35027055</column>
</row>
<row>
<column name="Notes">Area inspected ok. Bilge alarms inspected
ok.</column>
<column name="MaintLogID1">BRMR35027056</column>
</row>
<row>
<column name="Notes">Area inspected ok. bilge alarms tested
ok</column>
<column name="MaintLogID1">BRMR35027057</column>
</row>
<row>
<column name="Notes">All isolators operated. Port fwd fire main
isolator stiff. to be investigated</column>
<column name="MaintLogID1">BRMR35027058</column>
</row>
<row>
<column name="Notes">Week 1 hoses tested</column>
<column name="MaintLogID1">BRMR35027059</column>
</row>
<row>
<column name="Notes">week 1 hoses tested</column>
<column name="MaintLogID1">BRMR35027060</column>
</row>
<row>
<column name="Notes">Magnetic compas checked and found
satisfactory, mirrors are cleaned on weekly basis by 2/o officer. Main
source of light and emergency source of light operational.</column>
<column name="MaintLogID1">BRMR35027061</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027062</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027063</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Bottles pumped up as required.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027064</column>
</row>
<row>
<column name="Notes">Tested as per part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027065</column>
</row>
<row>
<column name="Notes">Completed as per pm.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027066</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027067</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Both alarms tested OK.</column>
<column name="MaintLogID1">BRMR35027068</column>
</row>
<row>
<column name="Notes">No discrepancies noticed.</column>
<column name="MaintLogID1">BRMR35027069</column>
</row>
<row>
<column name="Notes">Lights on for 4 hrs.</column>
<column name="MaintLogID1">BRMR35027070</column>
</row>
<row>
<column name="Notes">Route 7&8 tested OK.</column>
<column name="MaintLogID1">BRMR35027071</column>
</row>
<row>
<column name="Notes">Not in use at the moment.</column>
<column name="MaintLogID1">BRMR35027072</column>
</row>
<row>
<column name="Notes">tested weekly.</column>
<column name="MaintLogID1">BRMR35027073</column>
</row>
<row>
<column name="Notes">Alarms tested OK.</column>
<column name="MaintLogID1">BRMR35027074</column>
</row>
<row>
<column name="Notes">Found fault on detector in Diesel generator
room.
There was no alarm on oil mist panel in ECR.
Fan was running with not enough speed that is why unit itself was giving
alarm but speed was still enough to not activate detector fault or fan
fault on the main panel.
Have adjusted speed for this fan to clear this fault on the detector
itself.
Tested fan alarm by stopping it when power was switched on. All activated
OK.
</column>
<column name="MaintLogID1">BRMR35027075</column>
</row>
<row>
<column name="Notes">Defective monitor was in CSB no.1 not MSB no.1
New unit fitted and alarm tested OK.</column>
<column name="MaintLogID1">BRMR35027076</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs
Heater meggered > 100 megs</column>
<column name="MaintLogID1">BRMR35027077</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs
Heater meggered > 100 megs</column>
<column name="MaintLogID1">BRMR35027078</column>
</row>
<row>
<column name="Notes">New breaker received and fitted wioth same
setting on dip switches like original which was still in place.
Holder for the extension lever was faound cracked but we used this one
because breaker received without new holder.
Breaker operating OK.</column>
<column name="MaintLogID1">BRMR35027079</column>
</row>
<row>
<column name="Notes">Dynamo belt tension ok
Sprinkler pump suction valve operational.
</column>
<column name="MaintLogID1">BRMR35027080</column>
</row>
<row>
<column name="Notes">Dynamo belt tension ok
Sprinkler pump suction valve operational.
</column>
<column name="MaintLogID1">BRMR35027081</column>
</row>
<row>
<column name="Notes">Alarms & trips for MDO operation tested -
OK.</column>
<column name="MaintLogID1">BRMR35027083</column>
</row>
<row>
<column name="Notes">all parts greased.</column>
<column name="MaintLogID1">BRMR35027084</column>
</row>
<row>
<column name="Notes">all parts greased</column>
<column name="MaintLogID1">BRMR35027085</column>
</row>
<row>
<column name="Notes">ETA checked. Light working ok</column>
<column name="MaintLogID1">BRMR35027086</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned</column>
<column name="MaintLogID1">BRMR35027087</column>
</row>
<row>
<column name="Notes">New motor parts on order for this fan so no
action taken.
Fan inspected when running 4 amps</column>
<column name="MaintLogID1">BRMR35027088</column>
</row>
<row>
<column name="Notes">Trips and alarms tested.
Overspeed and lub oil pressure low trips tested for surveyor.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027089</column>
</row>
<row>
<column name="Notes">Tested by filling the tank up. Cut out switch
operational.
</column>
<column name="MaintLogID1">BRMR35027090</column>
</row>
<row>
<column name="Notes">Tested by filling the tank up. Cut out switch
operational.
</column>
<column name="MaintLogID1">BRMR35027091</column>
</row>
<row>
<column name="Notes">5 AA batteries replaced</column>
<column name="MaintLogID1">BRMR35027092</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered >100 megs.
</column>
<column name="MaintLogID1">BRMR35027093</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs.
</column>
<column name="MaintLogID1">BRMR35027094</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Motor meggered > 100 megs.</column>
<column name="MaintLogID1">BRMR35027095</column>
</row>
<row>
<column name="Notes">System operational.
tested OK.</column>
<column name="MaintLogID1">BRMR35027096</column>
</row>
<row>
<column name="Notes">received two new washer pumps together with
tank unit.
Fitted them to fwd and port side cameras.
Tested Ok.</column>
<column name="MaintLogID1">BRMR35027097</column>
</row>
<row>
<column name="Notes">Control linkage was removed and all relays
were proved free to move.
Govener trip micro switch was removed and the interals for the arm cleaned
out because a build
up of hardened grease inside was causing it to stick.
</column>
<column name="MaintLogID1">BRMR35027100</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.</column>
<column name="MaintLogID1">BRMR35027101</column>
</row>
<row>
<column name="Notes">All alarms and trips operational.
Auto start and stop functions correct.
High temperature trip at 110deg., warning 105 deg.
Cooling water high temperature alarm at 65 deg.
Emergency stop functional.
Safety valve tested - ok.
Air receivers low pressure alarms functional.
</column>
<column name="MaintLogID1">BRMR35027102</column>
</row>
<row>
<column name="Notes">V-belts checked and found in good condition,
tension satisfactory.
</column>
<column name="MaintLogID1">BRMR35027103</column>
</row>
<row>
<column name="Notes">All heads tested and calibrated.
The only one thats had parts changed is the one in the CCR. I've
fitted a new amplifier to this unit because
I could not obtain a zero position mV output reading. This was then tested
and spanned ok.
Note when fitting the new amplifier there is a chip with resister's on
it, inside the unit that require's fitting. I had to borrow one
from the old unit that I removed. But it seems that the new
amplifier's are coming without them fitted.
Two of the heads where isolated on the panel on A deck, don't know why
but they have been put back into service. </column>
<column name="MaintLogID1">BRMR35027104</column>
</row>
<row>
<column name="Notes">All filters found clean.
Smoke alarm functional.</column>
<column name="MaintLogID1">BRMR35027105</column>
</row>
<row>
<column name="Notes">All filters found clean.
Smoke alarm functional.
</column>
<column name="MaintLogID1">BRMR35027106</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist. All
operational.
</column>
<column name="MaintLogID1">BRMR35027107</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist. All
operational.
</column>
<column name="MaintLogID1">BRMR35027108</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist. All
operational.
</column>
<column name="MaintLogID1">BRMR35027109</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist. All
operational.
</column>
<column name="MaintLogID1">BRMR35027110</column>
</row>
<row>
<column name="Notes">All checked as per AMOS checklist. All
operational.
</column>
<column name="MaintLogID1">BRMR35027111</column>
</row>
<row>
<column name="Notes">New sensor has been fitted and reconnected to
the system.
To make this sensor working properly changed Ka parameter in the panel
menu.
Original Ka parameter was 0.3625 and changed it to 0.4011 (exact same like
for no.2)
System operational.</column>
<column name="MaintLogID1">BRMR35027114</column>
</row>
<row>
<column name="Notes">Completed as per PM.
No defects to report.
Machine enteked.</column>
<column name="MaintLogID1">BRMR35027115</column>
</row>
<row>
<column name="Notes">Cleaned shaft from excess oil also cleaned
brushes. Checked back emf on forward ICCP unit and
measure 1.4 volts for both anodes. Measured back emf on aft ICCP unit and
measured 1.4 volts DC on
both anodes. All connections secure. Bonding line on rudder secure and in
good order. System working
satisfactory, and switched off one day before entering port.
</column>
<column name="MaintLogID1">BRMR35027116</column>
</row>
<row>
<column name="Notes">Meggerred motor and found to be in excess of
30 M ohm. Cleaned out switchgear cabinet.
Checked all connections and found to be secure. Checked all wiriing and all
in good order.
Checked condition of horn and found to be in a good condition. System back
on and tested satisfactoy.</column>
<column name="MaintLogID1">BRMR35027117</column>
</row>
<row>
<column name="Notes">Switched system on and tuned into a known
working freq and station. System picked up signal
and recieved weather fax well. Checked all operating lights and dials and
all operational.
System shut down and power switched off. </column>
<column name="MaintLogID1">BRMR35027118</column>
</row>
<row>
<column name="Notes">Checked the operation of the GMDSS radio
station and DSC test carried out satisfacoty
All lights and displays checked and found to be fully functional. All
cableing secure.
System fully operational.</column>
<column name="MaintLogID1">BRMR35027119</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027121</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027122</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027123</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027124</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027125</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027126</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027127</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027128</column>
</row>
<row>
<column name="Notes">Completed as per PM. </column>
<column name="MaintLogID1">BRMR35027129</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027130</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027131</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027132</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027133</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027134</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027135</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027136</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027137</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027138</column>
</row>
<row>
<column name="Notes">Vacuum pump to be overhauled.</column>
<column name="MaintLogID1">BRMR35027139</column>
</row>
<row>
<column name="Notes">Pump free to rotate by hand, tank
refilled.</column>
<column name="MaintLogID1">BRMR35027140</column>
</row>
<row>
<column name="Notes">Pump free to rotate by hand, piston actuator
free to move.</column>
<column name="MaintLogID1">BRMR35027141</column>
</row>
<row>
<column name="Notes">Pump free to rotate by hand, piston actuator
free to move.</column>
<column name="MaintLogID1">BRMR35027142</column>
</row>
<row>
<column name="Notes">Unit ran then pumped down test carried out
with soap and meter</column>
<column name="MaintLogID1">BRMR35027143</column>
</row>
<row>
<column name="Notes">Unit ran then pumped down test carried out
with soap and meter</column>
<column name="MaintLogID1">BRMR35027144</column>
</row>
<row>
<column name="Notes"> test carried out with soap and meter</column>
<column name="MaintLogID1">BRMR35027145</column>
</row>
<row>
<column name="Notes">Unit ran then pumped down test carried out
with soap and meter</column>
<column name="MaintLogID1">BRMR35027146</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027147</column>
</row>
<row>
<column name="Notes">inspected whilst in port</column>
<column name="MaintLogID1">BRMR35027148</column>
</row>
<row>
<column name="Notes">ran on aux condenser</column>
<column name="MaintLogID1">BRMR35027149</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027150</column>
</row>
<row>
<column name="Notes">inspected during bearthing ops, no defects
observed</column>
<column name="MaintLogID1">BRMR35027151</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027152</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027153</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027154</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027155</column>
</row>
<row>
<column name="Notes">lubricated,operated</column>
<column name="MaintLogID1">BRMR35027156</column>
</row>
<row>
<column name="Notes">all satisfactory</column>
<column name="MaintLogID1">BRMR35027157</column>
</row>
<row>
<column name="Notes">all satisfactory</column>
<column name="MaintLogID1">BRMR35027158</column>
</row>
<row>
<column name="Notes">CN330 - 1.3 O2 & 0% LEL
CN346 - 1.2 O2 & 0% LEL
CN326 - 1.4 O2 & 0% LEL
CN325 - 1.3 O2 & 0% LEL</column>
<column name="MaintLogID1">BRMR35027159</column>
</row>
<row>
<column name="Notes">CN430 - 1.5 O2 & 0% LEL
CN446 - 1.4 O2 & 0% LEL
CN426 - 1.4 O2 & 0% LEL
CN425 - 1.4 O2 & 0% LEL</column>
<column name="MaintLogID1">BRMR35027160</column>
</row>
<row>
<column name="Notes">CN230 - 1.4 O2 & 0% LEL
CN246 - 1.4 O2 & 0% LEL
CN226 - 1.4 O2 & 0.5% LEL
CN225 - 1.4 O2 & 0% LEL</column>
<column name="MaintLogID1">BRMR35027161</column>
</row>
<row>
<column name="Notes">CN130 - 1.3 O2 & 0% LEL
CN146 - 1.2 O2 & 0% LEL
CN126 - 1.4 O2 & 0% LEL
CN125 - 1.3 O2 & 0% LEL</column>
<column name="MaintLogID1">BRMR35027162</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027163</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027164</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027165</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027166</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027167</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027168</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027169</column>
</row>
<row>
<column name="Notes">Removed condensate lines. Made good flange
faces where required.
A total of 7 flange joints.
Removed the drain trap assembly from the LNG vaporiser, and fitting it to
the forcing vaporiser.
The above drain trap has been overhauled. all valve faces lapped and the
float checked for water tightness.
The strainer has been removed and cleaned up. All the above has been
reasembled with new joints and
refitted to the LNG vaporiser.</column>
<column name="MaintLogID1">BRMR35027170</column>
</row>
<row>
<column name="Notes">Completed as per WO.</column>
<column name="MaintLogID1">BRMR35027171</column>
</row>
<row>
<column name="Notes">Valves operational.</column>
<column name="MaintLogID1">BRMR35027172</column>
</row>
<row>
<column name="Notes">Idle machinery free to turn by hand.</column>
<column name="MaintLogID1">BRMR35027174</column>
</row>
<row>
<column name="Notes">Cell cleaned, showing 0 ppm with clean fresh
water.Dessicator OK.</column>
<column name="MaintLogID1">BRMR35027175</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027176</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027177</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027178</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027179</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027180</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027181</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027182</column>
</row>
<row>
<column name="Notes">Checked system and found the readout was high
on the water potion of the log.
Adjusted the readout in the electronic boxs located in the bowthruster room
and readings are now
within 10 % + or - from the actual ships speed. This variation is due to
cavitaion. The log is working
good. Had also removed number one log probe and found clean. </column>
<column name="MaintLogID1">BRMR35027183</column>
</row>
<row>
<column name="Notes">Checked the operation of the system as per the
PM insturctions and found this system to be
working satisfactory. No defects
</column>
<column name="MaintLogID1">BRMR35027184</column>
</row>
<row>
<column name="Notes">Checked operation of radar and working well.
Checked power output and this has not deteriorated since
last check. Picking up targets in excess of 25 nm.</column>
<column name="MaintLogID1">BRMR35027185</column>
</row>
<row>
<column name="Notes">Checked the operation of the system and
working well. System picking up targets in excess of
25nm.</column>
<column name="MaintLogID1">BRMR35027186</column>
</row>
<row>
<column name="Notes">Run as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027187</column>
</row>
<row>
<column name="Notes">Run as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027188</column>
</row>
<row>
<column name="Notes">Run as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027189</column>
</row>
<row>
<column name="Notes">Pump run during monthly pumps change
over.</column>
<column name="MaintLogID1">BRMR35027190</column>
</row>
<row>
<column name="Notes">Pump run during monthly pumps change
over.</column>
<column name="MaintLogID1">BRMR35027191</column>
</row>
<row>
<column name="Notes">Stand-by diesel generator run for a day on
load during rough weather. All satisfactory.</column>
<column name="MaintLogID1">BRMR35027192</column>
</row>
<row>
<column name="Notes">All sets checked and tested, one bottle
recharged.
BA compressor run, all satisfactory.</column>
<column name="MaintLogID1">BRMR35027193</column>
</row>
<row>
<column name="Notes">Fault cleared.</column>
<column name="MaintLogID1">BRMR35027194</column>
</row>
<row>
<column name="Notes">Damper for EG room exhaust fan found stuck.
Pneumatic actuator condition checked - OK. Fire flap
bearings greased , flap unblocked - OK.</column>
<column name="MaintLogID1">BRMR35027195</column>
</row>
<row>
<column name="Notes">All v/v's operated</column>
<column name="MaintLogID1">BRMR35027196</column>
</row>
<row>
<column name="Notes">Wk 2 hoses tested ok</column>
<column name="MaintLogID1">BRMR35027197</column>
</row>
<row>
<column name="Notes">wk 2 hoses tested ok</column>
<column name="MaintLogID1">BRMR35027198</column>
</row>
<row>
<column name="Notes">No 4 trunk space inspection
Overall space in excellent condition. Coatings are fully intact apart from
a small spot of detachment
on the stbd side bay between fr79 & fr80.
There was some condensation present at the fwd end of the space ,
particularly around the vapour dome.
At the aft end of the space the mildew was heavier and some condensation
was also present.
operated</column>
<column name="MaintLogID1">BRMR35027231</column>
</row>
<row>
<column name="Notes">tank cleaned out floc amount as whitnessed
previously.
anodes inspected, current correct</column>
<column name="MaintLogID1">BRMR35027232</column>
</row>
<row>
<column name="Notes">tank cleaned out floc amount as whitnessed
previously.
anodes inspected, current correct</column>
<column name="MaintLogID1">BRMR35027233</column>
</row>
<row>
<column name="Notes">Patch welded to inbd side of treatment tank
Weld where the side meets the bottom plate cleaned of all corrosion and
coated
Hole had apeared where this weld met the vertical stiffiner.</column>
<column name="MaintLogID1">BRMR35027234</column>
</row>
<row>
<column name="Notes">Both stbd domestic and distilled tanks
inspected. a crack 200 mm long found next to the second vertical stiffiner
from the
fwd end 400 mm from deck level
Section around the crack removed and plate welded in
Distilled tank filled to prove bulkhead.</column>
<column name="MaintLogID1">BRMR35027235</column>
</row>
<row>
<column name="Notes">New sensor has been fitted and reconnected to
the system.
To make this sensor working properly changed Ka parameter in the panel
menu.
Original Ka parameter was 0.3625 and changed it to 0.4011 (exact same like
for no.2)
System operational.</column>
<column name="MaintLogID1">BRMR35027236</column>
</row>
<row>
<column name="Notes">Internal inspection carried out. Blades and
housing were cleaned. Sealing rubber in good condition.
Fan running nice and quiet no amp meter avalable on this fan.
Bearings not avalable onboard correct size has been ordered</column>
<column name="MaintLogID1">BRMR35027237</column>
</row>
<row>
<column name="Notes">Trunking and fanInspected and found to be in
good condition,
All fittings in good condition,
Coating acceptable for now,
All fittings cleaned of any accumalated deposits
Amps 1.1 no abnormal noise</column>
<column name="MaintLogID1">BRMR35027238</column>
</row>
<row>
<column name="Notes">Telephoned cargo console and telecon working
ok. Cargo console rang back and unable to hear
telecon both ways. Checked all connections, removed plugs and re-inserted,
checked relay was secure.
Called cargo control console and telecon worked both ways. Cargo console
telephoned bridge and
telecon working fine both ways. Tried several times calling and recieving
calls from cargo control
console and worked satisfactory on all further attempts. Bridge telephone
is now fully operational.
</column>
<column name="MaintLogID1">BRMR35027239</column>
</row>
<row>
<column name="Notes">Checked the operation and working well all
lights operating all cables in good condition.
All connections secure.
</column>
<column name="MaintLogID1">BRMR35027240</column>
</row>
<row>
<column name="Notes">Checked all indicators and all reading the
same.</column>
<column name="MaintLogID1">BRMR35027241</column>
</row>
<row>
<column name="Notes">Allexternal light switched on and all working.
Had low insulation indication and this all traced and
found to be caused by condensation.</column>
<column name="MaintLogID1">BRMR35027242</column>
</row>
<row>
<column name="Notes">Checked all indicators working and all
cableing secure. All wiring in a good condition.</column>
<column name="MaintLogID1">BRMR35027243</column>
</row>
<row>
<column name="Notes">Checked the operation of the dsc system and
working satisfactory. Called austlia and they answered
copied into gmdss log bood.</column>
<column name="MaintLogID1">BRMR35027244</column>
</row>
<row>
<column name="Notes">All c.ocks checked and telling the correct
time</column>
<column name="MaintLogID1">BRMR35027245</column>
</row>
<row>
<column name="Notes">Checked operation of hospital call with the
bridge and both positions fully operational.</column>
<column name="MaintLogID1">BRMR35027246</column>
</row>
<row>
<column name="Notes">Cylinder landed to Eastern Fire Pte Ltd
Singapore.
Air purity test completed and certificate issued.
Cylinder received back on board 20/07/07</column>
<column name="MaintLogID1">BRMR35027247</column>
</row>
<row>
<column name="Notes">Service completed by Manufacturer's
approved agents at Singapore 20/07/07
Certificate and service report filed in lifting gear register.</column>
<column name="MaintLogID1">BRMR35027248</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027254</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027255</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027256</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027257</column>
</row>
<row>
<column name="Notes">Tested</column>
<column name="MaintLogID1">BRMR35027258</column>
</row>
<row>
<column name="Notes">Ran on main condenser valves operated</column>
<column name="MaintLogID1">BRMR35027259</column>
</row>
<row>
<column name="Notes">Inspected during steering gear tests</column>
<column name="MaintLogID1">BRMR35027260</column>
</row>
<row>
<column name="Notes">Tested</column>
<column name="MaintLogID1">BRMR35027261</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027262</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027263</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027264</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027265</column>
</row>
<row>
<column name="Notes">Done when assisting with lift
inspection</column>
<column name="MaintLogID1">BRMR35027266</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027267</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027268</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027269</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027270</column>
</row>
<row>
<column name="Notes">lubricated and operated</column>
<column name="MaintLogID1">BRMR35027271</column>
</row>
<row>
<column name="Notes">Mushroom removed. motor and blades inspected.
Fan is running sommth 2.4 amps
hours 1156.9</column>
<column name="MaintLogID1">BRMR35027272</column>
</row>
<row>
<column name="Notes">Completed as per PM, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027273</column>
</row>
<row>
<column name="Notes">D/G run on load during Singapore anchoring.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027274</column>
</row>
<row>
<column name="Notes">Completed as per PM, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027275</column>
</row>
<row>
<column name="Notes">Completed as per PM, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027276</column>
</row>
<row>
<column name="Notes">Pum in use this month.</column>
<column name="MaintLogID1">BRMR35027277</column>
</row>
<row>
<column name="Notes">Pump run on test, all satisfactory.</column>
<column name="MaintLogID1">BRMR35027278</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027279</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027280</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027281</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027282</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027283</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027284</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027285</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027286</column>
</row>
<row>
<column name="Notes">pm completed as work order</column>
<column name="MaintLogID1">BRMR35027287</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027288</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027289</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027290</column>
</row>
<row>
<column name="Notes">Tested two areas route 10 and 11 all heads
tested working satisfactory. Fire system put back to
normal condition and bridge informed. One head situated over 6.6 kv
transformer, deemed unsafe to
test.
</column>
<column name="MaintLogID1">BRMR35027291</column>
</row>
<row>
<column name="Notes">Tested and found no transmission indication.
Checked power supply to transciever unit, and all ok.
Tested agaub and found to be fully operational. Successful DSC test
completed with Australia on 16 MHZ. </column>
<column name="MaintLogID1">BRMR35027292</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
</column>
<column name="MaintLogID1">BRMR35027293</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027294</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027295</column>
</row>
<row>
<column name="Notes">Tested call point meat room, dairy room and
flour room are satisfactionary. also checked hospital call point.</column>
<column name="MaintLogID1">BRMR35027296</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027297</column>
</row>
<row>
<column name="Notes">Hospital call point tested and found to be
fully operational.</column>
<column name="MaintLogID1">BRMR35027298</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027299</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027300</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027301</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027302</column>
</row>
<row>
<column name="Notes">Inform brige and checked angle indicator units
and found to read the same</column>
<column name="MaintLogID1">BRMR35027303</column>
</row>
<row>
<column name="Notes">tested by lift engineers all alarms trips.
Tested emergency phones to wheelhouse and motor room.Found all to be
working satisfactory.</column>
<column name="MaintLogID1">BRMR35027304</column>
</row>
<row>
<column name="Notes">Updated as per insructions all
satisfactory</column>
<column name="MaintLogID1">BRMR35027308</column>
</row>
<row>
<column name="Notes">Notices removed from lift once the lift had
been serviced by shore contractors Singapore 20th July 07</column>
<column name="MaintLogID1">BRMR35027309</column>
</row>
<row>
<column name="Notes">Alll tested and satisfactory</column>
<column name="MaintLogID1">BRMR35027310</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027311</column>
</row>
<row>
<column name="Notes">329 330 329 230 230 230
330 330 329 218 229 228 328 230.4
329 230.6 104 996 104 99.8 243 219
100 100 100 99.4 99.4 99.5 </column>
<column name="MaintLogID1">BRMR35027312</column>
</row>
<row>
<column name="Notes">all v/v's operated ok</column>
<column name="MaintLogID1">BRMR35027313</column>
</row>
<row>
<column name="Notes">hose tests carried out as per wk 3</column>
<column name="MaintLogID1">BRMR35027314</column>
</row>
<row>
<column name="Notes">hose tests carried out as per wk 3</column>
<column name="MaintLogID1">BRMR35027315</column>
</row>
<row>
<column name="Notes">wires checked. some pitting on exposed part of
wire.
Denzo removed from termination. termination in good condition.
wire well greased</column>
<column name="MaintLogID1">BRMR35027316</column>
</row>
<row>
<column name="Notes">wires checked. some pitting on exposed part of
wire.
Denzo removed from termination. termination in good condition.
wire well greased</column>
<column name="MaintLogID1">BRMR35027317</column>
</row>
<row>
<column name="Notes">pilot ladder in good condition.. note previous
repairs to spreaders.
all lashings secure and winnets in place</column>
<column name="MaintLogID1">BRMR35027318</column>
</row>
<row>
<column name="Notes">pilot ladder in good condition.. note previous
repairs to spreaders.
all lashings secure and winnets in place</column>
<column name="MaintLogID1">BRMR35027319</column>
</row>
<row>
<column name="Notes">all ok . greased as per pm.
lubricators topped up</column>
<column name="MaintLogID1">BRMR35027320</column>
</row>
<row>
<column name="Notes">all ok . greased as per pm.
lubricators topped up</column>
<column name="MaintLogID1">BRMR35027321</column>
</row>
<row>
<column name="Notes">all flaps and doors greased</column>
<column name="MaintLogID1">BRMR35027322</column>
</row>
<row>
<column name="Notes">air motor working ok. lubricators checked and
operational.</column>
<column name="MaintLogID1">BRMR35027323</column>
</row>
<row>
<column name="Notes">air motor working ok. lubricators checked and
operational.</column>
<column name="MaintLogID1">BRMR35027324</column>
</row>
<row>
<column name="Notes">all bilge alarms tested ok</column>
<column name="MaintLogID1">BRMR35027325</column>
</row>
<row>
<column name="Notes">all bilge alarms tested ok</column>
<column name="MaintLogID1">BRMR35027326</column>
</row>
<row>
<column name="Notes">Found that two winches forward had trouble
with starting and stopping one with stopping and one
with starting. Removed cover plate to electrical switchgear and checked
circuits and found that the
stop switch on winch 1 Motor 1 Port Fwd stop button was malfunctioning
hence the machine would not stop.
This button was replaced with new one and system tried and tested as
working satisfactory.
On removing cover plate tgo electrical switchgear on Winch motor 2 midship
aft on the focsle head,
found the stop button was permanently in the normally open position. This
was replaced with new
stop button and system checked and tested and found to be fully
operational. Replaced cover plates and
and both winches back into service.
</column>
<column name="MaintLogID1">BRMR35027327</column>
</row>
<row>
<column name="Notes">Em'cy fire pump found not pressurising
the line. Priming pump found seized up.
Sea water side of the priming pump opened, mouth rings found covered in
scale.
Rings and impeller cleaned, pump inspected.
Reassembled, tested, all satisfactory.
Pump back in service</column>
<column name="MaintLogID1">BRMR35027328</column>
</row>
<row>
<column name="Notes">completewd as per pm</column>
<column name="MaintLogID1">BRMR35027329</column>
</row>
<row>
<column name="Notes">Priming pump overhauled, new bearings
installed. Operating cylinder cleaned, O-rings & gasket replaced
automatic valve cleaned. Tank cleaned internally from mud and rust and
painted. Whole assembly
reinstalled and checked in operation.
Amos spare parts in stock -incorrect.</column>
<column name="MaintLogID1">BRMR35027330</column>
</row>
<row>
<column name="Notes">all satis</column>
<column name="MaintLogID1">BRMR35027331</column>
</row>
<row>
<column name="Notes">all satis</column>
<column name="MaintLogID1">BRMR35027332</column>
</row>
<row>
<column name="Notes">2 lightsicks needed relacement, due to
packaging damage
all satis</column>
<column name="MaintLogID1">BRMR35027333</column>
</row>
<row>
<column name="Notes">all satis</column>
<column name="MaintLogID1">BRMR35027334</column>
</row>
<row>
<column name="Notes">all gear ok .except paddles that require
repair.</column>
<column name="MaintLogID1">BRMR35027335</column>
</row>
<row>
<column name="Notes">all satis. lugs broken as per last months
history. new lights and containers to be ordered</column>
<column name="MaintLogID1">BRMR35027336</column>
</row>
<row>
<column name="Notes">all satis.</column>
<column name="MaintLogID1">BRMR35027337</column>
</row>
<row>
<column name="Notes">Valve ST353 Bonnet gasket replaced
High level float switch inspected.
Aux desup ran up and on for 3 hours LPSG shutdown no defects in controler
operations observed.
</column>
<column name="MaintLogID1">BRMR35027338</column>
</row>
<row>
<column name="Notes">Opened and closed valves from computer in
cargo control room. When valves were operned and closed,
WD 40 sprayed on valve spindle and all valves moving freely.</column>
<column name="MaintLogID1">BRMR35027339</column>
</row>
<row>
<column name="Notes">Checked all fire doors and magnetic
contactors. Tested and found all to be fully functional.</column>
<column name="MaintLogID1">BRMR35027340</column>
</row>
<row>
<column name="Notes">Checked all wiring and found to be in a good
condition.
Checked all filters in the tumble driers both crew and officers all cleaned
out.
Checked operation of all tumble driers and found to operate correctly also
stopping when door opened.
Checked the operation of the roller iron and found to operate correctly.
Checked the earth leakage trips on all relevant machines and found to be
fully functional.
No defects to report.
</column>
<column name="MaintLogID1">BRMR35027341</column>
</row>
<row>
<column name="Notes">High and low level alarms operational as well
as low shell pressure alarm. Done in conjunction with LPSG shutting down
for maintenance.</column>
<column name="MaintLogID1">BRMR35027343</column>
</row>
<row>
<column name="Notes">Purge air sufficient.
Optical lenses cleaned.
Mirrors cleaned.
Silica lamp replaced with new one.
All cable connections in good order.
No abnormalities observed.
High smoke alarm operational.</column>
<column name="MaintLogID1">BRMR35027344</column>
</row>
<row>
<column name="Notes">Purge air sufficient.
Optical lenses cleaned.
Mirrors cleaned.
Silica lamp replaced with new one.
All cable connections in good order.
No abnormalities observed.
High smoke alarm operational.</column>
<column name="MaintLogID1">BRMR35027345</column>
</row>
<row>
<column name="Notes">completed by Lutz service agents at singapore
on 20th July 2007.
Service report and certificate filed in lifting gear register. Copy Emailed
to BPS</column>
<column name="MaintLogID1">BRMR35027346</column>
</row>
<row>
<column name="Notes">All requirements in place. Lift reinstated on
25th july 2007 after confirmation from BPS</column>
<column name="MaintLogID1">BRMR35027347</column>
</row>
<row>
<column name="Notes">Sband radar al nuts and bolts checked on
scanner and tight. Internal clean,
all cables in good condition.
No faults reported.
X band radar, brushes still in good condition. But bearings badly in need
of change, new bearings
being ordered. All clean inside and all connections good. All external nuts
and bolts tight. No
reports of malfuction.
</column>
<column name="MaintLogID1">BRMR35027348</column>
</row>
<row>
<column name="Notes">Carried out on all 3 motors, ships compliment
instructed in use
comunications with bridge checked</column>
<column name="MaintLogID1">BRMR35027349</column>
</row>
<row>
<column name="Notes">A overall check of all fixtures and fittings
has been carried out.Leak tests have been carried out using electric, soap
and gas
All valves operated through full travel.</column>
<column name="MaintLogID1">BRMR35027350</column>
</row>
<row>
<column name="Notes">A overall check of all fixtures and fittings
has been carried out.Leak tests have been carried out using electric, soap
and gas
All valves operated through full travel.</column>
<column name="MaintLogID1">BRMR35027351</column>
</row>
<row>
<column name="Notes">not done vibration monitering carried out
regulary on this machine</column>
<column name="MaintLogID1">BRMR35027352</column>
</row>
<row>
<column name="Notes">not done vibration monitering carried out
regulary on this machine</column>
<column name="MaintLogID1">BRMR35027353</column>
</row>
<row>
<column name="Notes">OIl changed, oil filter changed
Both valves on liquid level glass found to be passing</column>
<column name="MaintLogID1">BRMR35027354</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027355</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027356</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027357</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027358</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027359</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027360</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027361</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027362</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027363</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027364</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027365</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. Cleaned out switchgear box
from excess dust.
</column>
<column name="MaintLogID1">BRMR35027366</column>
</row>
<row>
<column name="Notes">using IR gun tested temperature of oil in both
pans and checked that the thermostat switched off
and on this was successful and the thermostates operated at the correct
temperture settings
Confirmed by the IR readings. The lights went on and off accordingly
indicating the operation of the
thermostats. </column>
<column name="MaintLogID1">BRMR35027367</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027368</column>
</row>
<row>
<column name="Notes">Found system in fault mode indicating faults s
and b.
Switched off as per instructions and after 30 seconds switched back
on,system cleared faults and
working satisfactory.</column>
<column name="MaintLogID1">BRMR35027369</column>
</row>
<row>
<column name="Notes">Checked visually and found system to be fully
operational. All lights and dials fully operational.
</column>
<column name="MaintLogID1">BRMR35027370</column>
</row>
<row>
<column name="Notes">Checked visually and found system to be fully
operational. All lights and dials fully operational.
</column>
<column name="MaintLogID1">BRMR35027371</column>
</row>
<row>
<column name="Notes">Checked visually and found system to be fully
operational. All lights and dials fully operational.
</column>
<column name="MaintLogID1">BRMR35027372</column>
</row>
<row>
<column name="Notes">Checked visually and found system to be fully
operational. All lights and dials fully operational.
</column>
<column name="MaintLogID1">BRMR35027373</column>
</row>
<row>
<column name="Notes">Shutter found not operational.New shutter coil
fitted.
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027374</column>
</row>
<row>
<column name="Notes">Inspected and found to be working
satisfactory.</column>
<column name="MaintLogID1">BRMR35027375</column>
</row>
<row>
<column name="Notes">Inspected and found to be working
satisfactory.</column>
<column name="MaintLogID1">BRMR35027376</column>
</row>
<row>
<column name="Notes">Gasket joint replaced, valve plug inspected no
defects observed</column>
<column name="MaintLogID1">BRMR35027377</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027378</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027379</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027380</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027381</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027382</column>
</row>
<row>
<column name="Notes">inspected all fixtures and fittings</column>
<column name="MaintLogID1">BRMR35027383</column>
</row>
<row>
<column name="Notes">Ran on aux condenser all valves
operated</column>
<column name="MaintLogID1">BRMR35027384</column>
</row>
<row>
<column name="Notes">Time out tested, all public rooms
tested</column>
<column name="MaintLogID1">BRMR35027385</column>
</row>
<row>
<column name="Notes">remains of old dolomite removed, inlet and
outlet filters replaced,
guage and drain filters inspected,
System flushed </column>
<column name="MaintLogID1">BRMR35027386</column>
</row>
<row>
<column name="Notes">Ph reading of 8 withy the new
dolomite</column>
<column name="MaintLogID1">BRMR35027387</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027388</column>
</row>
<row>
<column name="Notes">greased and operated</column>
<column name="MaintLogID1">BRMR35027389</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027390</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027391</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027392</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027393</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027394</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027395</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027396</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027397</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027398</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027399</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027400</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027401</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027402</column>
</row>
<row>
<column name="Notes">D/G LO sump level switch found not functional.
Float tank removed from crankcase, float found stuck with muck.
All cleaned and tested, satisfactory.
D/G back to stand by.</column>
<column name="MaintLogID1">BRMR35027403</column>
</row>
<row>
<column name="Notes">Tested fire detection equipment and alarms.
All fire detection (Route 12,13) are good.</column>
<column name="MaintLogID1">BRMR35027404</column>
</row>
<row>
<column name="Notes">checked external lighting. Earth meters test
no satisfactionary. Found port fwd floodlight out.
Also traced earth fault to stbd side floodlight. To Remedy.</column>
<column name="MaintLogID1">BRMR35027405</column>
</row>
<row>
<column name="Notes">DSC test carried out with Australian. Tested
ok rx/tx.</column>
<column name="MaintLogID1">BRMR35027406</column>
</row>
<row>
<column name="Notes">Tested refrigeration space locked in alarms
for meat room,dairy room and flour room.
All alarms ok.</column>
<column name="MaintLogID1">BRMR35027407</column>
</row>
<row>
<column name="Notes">Tested hospital 2 alarms. All alarms
ok.</column>
<column name="MaintLogID1">BRMR35027408</column>
</row>
<row>
<column name="Notes">Tested elevator alarms and emergency phone.
All tested ok.</column>
<column name="MaintLogID1">BRMR35027409</column>
</row>
<row>
<column name="Notes">Flaps operated - OK</column>
<column name="MaintLogID1">BRMR35027410</column>
</row>
<row>
<column name="Notes">Checked rudder angle indicator and checked
linkages on feedback unit in steering gear room.all indivators are reading
the same and foolowing
the same indication on the bridge good.
</column>
<column name="MaintLogID1">BRMR35027413</column>
</row>
<row>
<column name="Notes">Pumps free to rotate by hand.</column>
<column name="MaintLogID1">BRMR35027414</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027415</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027417</column>
</row>
<row>
<column name="Notes">pm completed as per work order </column>
<column name="MaintLogID1">BRMR35027421</column>
</row>
<row>
<column name="Notes">all ok . new harness placed in lift as per new
requirements.
safety harness list updated accordingly</column>
<column name="MaintLogID1">BRMR35027423</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027425</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027426</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027427</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027428</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027429</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027430</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027431</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027432</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027433</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027434</column>
</row>
<row>
<column name="Notes">pm compoleted as per work order</column>
<column name="MaintLogID1">BRMR35027435</column>
</row>
<row>
<column name="Notes">eye wash bottle replaced in bridge first aid
kit.
all other kits complete and in date</column>
<column name="MaintLogID1">BRMR35027436</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027437</column>
</row>
<row>
<column name="Notes">all ok. some minor repairs required on braces
of trousers</column>
<column name="MaintLogID1">BRMR35027438</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027439</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027440</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027441</column>
</row>
<row>
<column name="Notes">Further to lack of history written in original
W.O. MER/07/0426
Valve found to be lifting at approx 52kpa.
Valve removed from main, stripped down, cleaned and checked. All found in
good order
Set up to lift at 60kpa and refitted.</column>
<column name="MaintLogID1">BRMR35027442</column>
</row>
<row>
<column name="Notes">all spaces ok. bilge alrms tested
satis</column>
<column name="MaintLogID1">BRMR35027443</column>
</row>
<row>
<column name="Notes">all spaces ok. bilge alarms tested
satis</column>
<column name="MaintLogID1">BRMR35027444</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027445</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027446</column>
</row>
<row>
<column name="Notes">All isolators gresead and operated</column>
<column name="MaintLogID1">BRMR35027447</column>
</row>
<row>
<column name="Notes">Hoses tested as per wk 4 schedule. all
ok</column>
<column name="MaintLogID1">BRMR35027448</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027449</column>
</row>
<row>
<column name="Notes">hoses tested as per wk 4 schedule. all
ok</column>
<column name="MaintLogID1">BRMR35027450</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027451</column>
</row>
<row>
<column name="Notes">No lights showing on Back Up PSU for port
boiler Instrumentation (Kongsberg) 3.24SIC unit.
New spare fitted.</column>
<column name="MaintLogID1">BRMR35027453</column>
</row>
<row>
<column name="Notes">Carried out as per the instructions all
updated</column>
<column name="MaintLogID1">BRMR35027454</column>
</row>
<row>
<column name="Notes">High levels of vibrations recorded.
Electric motor disconnected from the compressor, drive coupling removed and
inspected.
Rubber element found in good condition.
Unit reassembled and returned into service.
</column>
<column name="MaintLogID1">BRMR35027455</column>
</row>
<row>
<column name="Notes">3 bottles removed to upperdeck and topped up
useing BA compressor to 200 bar
all system checked for laks and returned to service</column>
<column name="MaintLogID1">BRMR35027456</column>
</row>
<row>
<column name="Notes">Visual inspection carried out and all limit
switches found to be secure.
2/Eng carries out inspection of these limit switches on a regular bais and
pistons stroked when
possible. All limit switches found to be fully functional and in good
condition.
</column>
<column name="MaintLogID1">BRMR35027457</column>
</row>
<row>
<column name="Notes">Visual inspection of all limit switches and
found all to be in good condition and secure.
2/Eng carries out regular inspection and testing of these switches where
possible pistons are stroked,
finding all in good working order.
</column>
<column name="MaintLogID1">BRMR35027458</column>
</row>
<row>
<column name="Notes">Visual inspection carried out and all limit
switches found to be secure.
2/Eng carries out regular inspection of these limit switches and test them
by stroking the pistons when
possible having found them all to be fully operational. </column>
<column name="MaintLogID1">BRMR35027459</column>
</row>
<row>
<column name="Notes">Visual inspection carried out and found all
limit switches secure.
2/Eng carries out regular inspection of these limit switches and tests
where possible by stoking the
pistons and finds that they are all operational.
</column>
<column name="MaintLogID1">BRMR35027460</column>
</row>
<row>
<column name="Notes">Pyrotechnics in date and in good condition.
All satisfactory</column>
<column name="MaintLogID1">BRMR35027461</column>
</row>
<row>
<column name="Notes">Equipment checked, rustproof dipper not found
(to order). Painters require to be renewed. First aid kit renewed.
All other equipment in good condition and in date. Boat cleaned inside and
outside. All checks satisfactory. </column>
<column name="MaintLogID1">BRMR35027462</column>
</row>
<row>
<column name="Notes">Equipment checked, rustproof dipper not found
and tin openers found rusted (to order). Painters require to be renewed
and one oar to be repaired. First aid kit renewed. All other equipment in
good condition and in date. Boat cleaned inside
and outside. All checks satisfactory. </column>
<column name="MaintLogID1">BRMR35027463</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027464</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027465</column>
</row>
<row>
<column name="Notes">E/G on load test carried out as per PM.
Starting and loading sequence found working correctly.</column>
<column name="MaintLogID1">BRMR35027466</column>
</row>
<row>
<column name="Notes">E/G weekly routine run together with on load
test. All satisfactory.</column>
<column name="MaintLogID1">BRMR35027467</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027468</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027469</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027470</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35027471</column>
</row>
<row>
<column name="Notes">Visually inspected. All tested and working
correctly.</column>
<column name="MaintLogID1">BRMR35027472</column>
</row>
<row>
<column name="Notes">Blige, Fire and G/S Pump No 1 & 2 and S/G
Spray Water Pump Vacuum Pumps found in good order.
Shafts free to turn, actuating cylinders operational.</column>
<column name="MaintLogID1">BRMR35027473</column>
</row>
<row>
<column name="Notes">No 1 Evap sea water pipe found leaking from
sensing line connection.
Pipe removed, holed section replaced, pipe back in.</column>
<column name="MaintLogID1">BRMR35027474</column>
</row>
<row>
<column name="Notes">Checked navigation lights and insulation
tested. All ok. Found damaged cover on ( aft lower nav.lamp).
One lamp fitment to order.</column>
<column name="MaintLogID1">BRMR35027475</column>
</row>
<row>
<column name="Notes">No 1 Evap Dist. Pump leaking from mechanical
seal.
Pump removed, seal replaced, pump inspected, satisfactory,
Pump and piping reassembled.</column>
<column name="MaintLogID1">BRMR35027476</column>
</row>
<row>
<column name="Notes">Checked emergency lights.Switched off relvent
breaker for 30 min.
All battery power lights worked satisfactory. </column>
<column name="MaintLogID1">BRMR35027477</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027478</column>
</row>
<row>
<column name="Notes">all satisfactory</column>
<column name="MaintLogID1">BRMR35027479</column>
</row>
<row>
<column name="Notes">As per instructions shorted out terminals 11
and 12 also 21 and 22 on the thermostat.
Thermostat safety activated at 221deg C on the stbd side and on port side
measured 220 deg C.
Safties reset and checked thermostat operation after oil had cooled down
and both operating
satisfactory.
</column>
<column name="MaintLogID1">BRMR35027480</column>
</row>
<row>
<column name="Notes">Checked and megger tested found >100M ohms.
Cleand switch box from dust.Checked connection and found too be secure.
All wiring in good condition.Contactors off the tottaly enclosed type.
Checked continuity of contactors and
found to be good. Checked motor and found to be clean.
</column>
<column name="MaintLogID1">BRMR35027481</column>
</row>
<row>
<column name="Notes">Leaking hydr. coupling on suction valve -
coupling renewed, oil topped up, tested, satisfactory.</column>
<column name="MaintLogID1">BRMR35027482</column>
</row>
<row>
<column name="Notes">V-belts checked, found in good condition.
Pulleys checked for misalignment, impeller cleaned.
V-belts tension checked - 1 cm deflection 3 kG force (each). No change in
vibration after restart.
Fan tested with new pair of spare V-belts, with different tension level -
vibration persisted without any
noticeable change. Shaft bearings opened - old grease removed, condition
inspected - OK, bearings
filled with high temperature grease and reassembled. Electric motor started
with V-belts off - no
vibration. Olds V-belts reinstalled. Flue gas thermocouple replaced ( due
to false flue gas temp. alarms).
Electric motor's bearings replaced - vibration persisted. Fan's
impeller pulled off the shaft and cleaned.
Impeller found to be distorted and should be replaced.
Fan reassembled and tested. Awaiting delivery of new impeller. Prolonged
periods of incinerator
operation should be avoided.
</column>
<column name="MaintLogID1">BRMR35027483</column>
</row>
<row>
<column name="Notes">Port boat hung off using hanging off gear.
Release gear tested satisfactorily.
Hooks greased and worked. </column>
<column name="MaintLogID1">BRMR35027484</column>
</row>
<row>
<column name="Notes">stbd boat hung off using hanging off gear.
Fwd hook found to be catching on cam when released. It would not clear the
cam without force.
The cam is marked in a way that suggests the problem has been present from
new.
Recent in water tests indicate no problem releasing when load applied.
Which would suggest that
the interference with the cam is slight, making it difficult to release
with no load.
C/E and Master made aware of defect. </column>
<column name="MaintLogID1">BRMR35027485</column>
</row>
<row>
<column name="Notes">Unit removed to workshop
drive end bearing found to be damaged .
Both bearings replaced fan back in service
6202 zz
6203 zz</column>
<column name="MaintLogID1">BRMR35027486</column>
</row>
<row>
<column name="Notes">Pump operation observed amps and through put
satisfactory.
coupling rubbers inspected.
holding down arrangement checked.
Safety valve inspected
seal oil changed.
The instruction manual recomends this work at either 20000 hrs or 4 years
so seal faces
not inspected at this time as there are no leaks</column>
<column name="MaintLogID1">BRMR35027487</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
Hours 16127</column>
<column name="MaintLogID1">BRMR35027488</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
hours</column>
<column name="MaintLogID1">BRMR35027489</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
hours 32977</column>
<column name="MaintLogID1">BRMR35027490</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
hours 33192</column>
<column name="MaintLogID1">BRMR35027491</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
hours 34522</column>
<column name="MaintLogID1">BRMR35027492</column>
</row>
<row>
<column name="Notes">Gas side tested
evaporator coils cleaned
Dranes proved
All electrical conections checked
Filter cleaned
hours 34522</column>
<column name="MaintLogID1">BRMR35027493</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027494</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027495</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027496</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027497</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027498</column>
</row>
<row>
<column name="Notes">cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027499</column>
</row>
<row>
<column name="Notes">Sample analysis received 20/06/07 satisfactory
for further use. See analysis report C/Eng.</column>
<column name="MaintLogID1">BRMR35027500</column>
</row>
<row>
<column name="Notes">completed all found in good order</column>
<column name="MaintLogID1">BRMR35027501</column>
</row>
<row>
<column name="Notes">Carried out as per instructions for merchant
13 strokes per bearing </column>
<column name="MaintLogID1">BRMR35027502</column>
</row>
<row>
<column name="Notes">control vanes and trunking flaps
greased</column>
<column name="MaintLogID1">BRMR35027503</column>
</row>
<row>
<column name="Notes">Valve stems checked
operation of valves observed over the last month
all glands tight
electrical connections checkes inside microswitches
all switch arms secure, showing readings correct to positions on ias
Solonoid racks inspected no air leaks</column>
<column name="MaintLogID1">BRMR35027504</column>
</row>
<row>
<column name="Notes">Valve stems checked
operation of valves observed over the last month
all glands tight
electrical connections checkes inside microswitches
all switch arms secure, showing readings correct to positions on ias
Solonoid racks inspected no air leaks</column>
<column name="MaintLogID1">BRMR35027505</column>
</row>
<row>
<column name="Notes">All alarms and trips tested.
Auto start and stop correct.
High temperature warning alarm operational, compressor trips at 110 deg.
Cooling water high temperature alarm at 65 deg.
Emergency stop button operational.
Safety valve removed and bench tested, operates at 13 bar.
Both air receivers low pressure alarms tested.
</column>
<column name="MaintLogID1">BRMR35027506</column>
</row>
<row>
<column name="Notes">V-belts tension checked.
Tension correct and uniform on all the belts.</column>
<column name="MaintLogID1">BRMR35027507</column>
</row>
<row>
<column name="Notes">V-belts tension satisfactory and uniform on
all of the belts.</column>
<column name="MaintLogID1">BRMR35027508</column>
</row>
<row>
<column name="Notes">All CO2 extingushers checked, weight correct,
general condition good, details on T:/ Engineering
Department/JE/Fire Equipment & Dampers/2007/Fire
Extinguishers.xls</column>
<column name="MaintLogID1">BRMR35027509</column>
</row>
<row>
<column name="Notes">Checked and tested EPIRB. ALL working
satisfacory.</column>
<column name="MaintLogID1">BRMR35027510</column>
</row>
<row>
<column name="Notes">all equiptment inspected no defects to
report</column>
<column name="MaintLogID1">BRMR35027511</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027512</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027513</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027514</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027515</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027516</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027517</column>
</row>
<row>
<column name="Notes">Received by Fujitsu 1/8/07</column>
<column name="MaintLogID1">BRMR35027518</column>
</row>
<row>
<column name="Notes">Whistle inspected.
Found in good condition.
</column>
<column name="MaintLogID1">BRMR35027519</column>
</row>
<row>
<column name="Notes">Unit tested for manual and remote operations.
Air filter cleaned.
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027520</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027521</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027522</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027523</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027524</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027525</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027526</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027527</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027528</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027529</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027530</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027531</column>
</row>
<row>
<column name="Notes">Tested OK</column>
<column name="MaintLogID1">BRMR35027532</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected
CSE made into trunking mopped out and dranes proved clear</column>
<column name="MaintLogID1">BRMR35027533</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected
CSE made into trunking mopped out and dranes proved clear</column>
<column name="MaintLogID1">BRMR35027534</column>
</row>
<row>
<column name="Notes">New Window Glass Unit (consisting outer &
3 inner glasses) fitted complete with new seals and fastenings.</column>
<column name="MaintLogID1">BRMR35027535</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected</column>
<column name="MaintLogID1">BRMR35027536</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected</column>
<column name="MaintLogID1">BRMR35027537</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected</column>
<column name="MaintLogID1">BRMR35027538</column>
</row>
<row>
<column name="Notes">filters cleaned frames inspected</column>
<column name="MaintLogID1">BRMR35027539</column>
</row>
<row>
<column name="Notes">carried out on both plants when shutdown for
trunking inspection</column>
<column name="MaintLogID1">BRMR35027540</column>
</row>
<row>
<column name="Notes">filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027541</column>
</row>
<row>
<column name="Notes">filters cleaned and inspected</column>
<column name="MaintLogID1">BRMR35027542</column>
</row>
<row>
<column name="Notes">Salinometers and solenoids tested -
operational.</column>
<column name="MaintLogID1">BRMR35027543</column>
</row>
<row>
<column name="Notes">Salinometers and solenoids tested -
operational.</column>
<column name="MaintLogID1">BRMR35027544</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027545</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027546</column>
</row>
<row>
<column name="Notes">Unit inspected.
Residual pressure in the towers during regeneration within limits.
Moisture indicator shows green colour.
Differential pressure gauges indicators in green areas.
Condensate drain assembly operational.
</column>
<column name="MaintLogID1">BRMR35027547</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027548</column>
</row>
<row>
<column name="Notes">Completed as per PM.</column>
<column name="MaintLogID1">BRMR35027549</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027550</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027551</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027552</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027553</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027554</column>
</row>
<row>
<column name="Notes">all test conditions run , and compared with
original results. All ok
printouts filed.</column>
<column name="MaintLogID1">BRMR35027555</column>
</row>
<row>
<column name="Notes">All ELSA sets inspected as per PM. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027556</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027557</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027558</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027559</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027560</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027561</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027562</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok </column>
<column name="MaintLogID1">BRMR35027563</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027564</column>
</row>
<row>
<column name="Notes">Valves operated</column>
<column name="MaintLogID1">BRMR35027566</column>
</row>
<row>
<column name="Notes">Free movement of shaft and actuating piston.
Water tk refilled.</column>
<column name="MaintLogID1">BRMR35027571</column>
</row>
<row>
<column name="Notes">Free to turn by hand.</column>
<column name="MaintLogID1">BRMR35027572</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027573</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027574</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027575</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027576</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027577</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027578</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027579</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027580</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027581</column>
</row>
<row>
<column name="Notes">Tested</column>
<column name="MaintLogID1">BRMR35027582</column>
</row>
<row>
<column name="Notes">Ran on aux condenser</column>
<column name="MaintLogID1">BRMR35027583</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027584</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027585</column>
</row>
<row>
<column name="Notes">Flushed</column>
<column name="MaintLogID1">BRMR35027586</column>
</row>
<row>
<column name="Notes">Done as part of monthly PM</column>
<column name="MaintLogID1">BRMR35027587</column>
</row>
<row>
<column name="Notes">Lek tested and pumped down level ok</column>
<column name="MaintLogID1">BRMR35027588</column>
</row>
<row>
<column name="Notes">Ran on test then pumped down, leak
tested</column>
<column name="MaintLogID1">BRMR35027589</column>
</row>
<row>
<column name="Notes">Oil sight glasses on both compressors cleaned.
Full system leak tested
operation of all elements working satisfactory</column>
<column name="MaintLogID1">BRMR35027590</column>
</row>
<row>
<column name="Notes">oil approx 1.5 on oil guage with lp of 0.8
when oil side bled off
LP 0.4
HP 21.5</column>
<column name="MaintLogID1">BRMR35027591</column>
</row>
<row>
<column name="Notes">Condensers inspected from fwd end no
defects</column>
<column name="MaintLogID1">BRMR35027592</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027593</column>
</row>
<row>
<column name="Notes">Lubricated and operated</column>
<column name="MaintLogID1">BRMR35027594</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027595</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027596</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027597</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027598</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027599</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027600</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027601</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027602</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027603</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027604</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027605</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027606</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027607</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027608</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027609</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027610</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027611</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027612</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027613</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027614</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027615</column>
</row>
<row>
<column name="Notes">Hoses tested as per wk5. all satis</column>
<column name="MaintLogID1">BRMR35027616</column>
</row>
<row>
<column name="Notes">hoses tested as per wk 5.all satis</column>
<column name="MaintLogID1">BRMR35027617</column>
</row>
<row>
<column name="Notes">all bilge alarms tested ok. </column>
<column name="MaintLogID1">BRMR35027618</column>
</row>
<row>
<column name="Notes">all bilge alarms tested ok</column>
<column name="MaintLogID1">BRMR35027619</column>
</row>
<row>
<column name="Notes">Cooling air inlets free from
obstructions.</column>
<column name="MaintLogID1">BRMR35027621</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027622</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027623</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027624</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027625</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027626</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027627</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027628</column>
</row>
<row>
<column name="Notes">pm completed testing as per work order
</column>
<column name="MaintLogID1">BRMR35027629</column>
</row>
<row>
<column name="Notes">pm completed testing as per work
order</column>
<column name="MaintLogID1">BRMR35027630</column>
</row>
<row>
<column name="Notes">pm completed testing as per work
order</column>
<column name="MaintLogID1">BRMR35027631</column>
</row>
<row>
<column name="Notes">pm completed testing as per work
order</column>
<column name="MaintLogID1">BRMR35027632</column>
</row>
<row>
<column name="Notes">Sent DSC call to australia on 16 mhz from
mozambique channel. TX/RX received good both ways. </column>
<column name="MaintLogID1">BRMR35027633</column>
</row>
<row>
<column name="Notes">Alarm tested and sounded well in engine room
and also on the bridge.
Telephone operating satisfactory.</column>
<column name="MaintLogID1">BRMR35027634</column>
</row>
<row>
<column name="Notes">Confirmed with wheelhouse that rudder
indicator angle is reading correctlty and indicate the same
position in the steering gear room and the bridge indicator.</column>
<column name="MaintLogID1">BRMR35027635</column>
</row>
<row>
<column name="Notes">Switched on all external lighting and all
worked ok.
isolasion down to begin with, this cleaned after a couple of hours.
</column>
<column name="MaintLogID1">BRMR35027636</column>
</row>
<row>
<column name="Notes">tested hospital alarms. All is ok.</column>
<column name="MaintLogID1">BRMR35027637</column>
</row>
<row>
<column name="Notes">tested refrigeration space locked in alarm.
All is ok.</column>
<column name="MaintLogID1">BRMR35027638</column>
</row>
<row>
<column name="Notes">Checked, clenaed all and megger tested motor
(>100 M ohm).
All connections checked and found be secure.
All wiring are good condition.</column>
<column name="MaintLogID1">BRMR35027639</column>
</row>
<row>
<column name="Notes">Switched- off and removed covers, visual
inspection. All is ok.</column>
<column name="MaintLogID1">BRMR35027640</column>
</row>
<row>
<column name="Notes">Switched- off and removed covers, visual
inspection. All is ok.</column>
<column name="MaintLogID1">BRMR35027641</column>
</row>
<row>
<column name="Notes">Following fin QA MOC MOC Fin -36-07 this
monthly pm not carried out.
Full safety inspection carried out at the end on July by shore side firm.
Next six monthly inspection due in january 2008</column>
<column name="MaintLogID1">BRMR35027642</column>
</row>
<row>
<column name="Notes">Zeroed as per manufactures
instructions</column>
<column name="MaintLogID1">BRMR35027643</column>
</row>
<row>
<column name="Notes">Zeroed as per manufactures
instructions</column>
<column name="MaintLogID1">BRMR35027644</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027645</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines</column>
<column name="MaintLogID1">BRMR35027646</column>
</row>
<row>
<column name="Notes">Residual pressure within limits.
Moisture indicator swows green colour.
Differential pressure gauges in green area.
Condensate drain operational.
</column>
<column name="MaintLogID1">BRMR35027647</column>
</row>
<row>
<column name="Notes">All sea water strainers cleaned and inspected,
satisfactory.
E/R spray pump strainer anodes replaced with fire line press. pump ones -
no original ones on board.
</column>
<column name="MaintLogID1">BRMR35027648</column>
</row>
<row>
<column name="Notes">No 1 T/A LO filter changed over and inspected
- spotless.</column>
<column name="MaintLogID1">BRMR35027649</column>
</row>
<row>
<column name="Notes">All satisfactory. Equipment complete and in
good condition</column>
<column name="MaintLogID1">BRMR35027650</column>
</row>
<row>
<column name="Notes">Equipment in good condition and complete.
Found extra set of shoulder harness and extra foul weather
blanket.</column>
<column name="MaintLogID1">BRMR35027651</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure.</column>
<column name="MaintLogID1">BRMR35027652</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. </column>
<column name="MaintLogID1">BRMR35027653</column>
</row>
<row>
<column name="Notes">Cleaned contactors. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure.</column>
<column name="MaintLogID1">BRMR35027654</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure.</column>
<column name="MaintLogID1">BRMR35027655</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure.</column>
<column name="MaintLogID1">BRMR35027656</column>
</row>
<row>
<column name="Notes"> Checked all cableing and found in good order.
Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure.checked contactors.</column>
<column name="MaintLogID1">BRMR35027657</column>
</row>
<row>
<column name="Notes">Cleaned contacotrs. Checked all cableing and
found in good order. Checked all connections
and all secure. Meggerred motor and found to be greater than 100 M ohm.
motor checked and
found to be clean and all connections secure. </column>
<column name="MaintLogID1">BRMR35027658</column>
</row>
<row>
<column name="Notes">Checked all wiring and found to be in good
condition.
Checked all connections and all found to be secure,
Meggerred motor and found to be greater than 100 M ohm.
Cleaned motor fan and outside of motor on the cooling veins.
Checked operation on test mode and operating satisfactory.
Checked overload trip and fully functional.
Checked Contactors and all found to be clean.
</column>
<column name="MaintLogID1">BRMR35027659</column>
</row>
<row>
<column name="Notes">Turning gear oil changed.</column>
<column name="MaintLogID1">BRMR35027660</column>
</row>
<row>
<column name="Notes">Alarm and trips tested as per work order.
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027661</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027662</column>
</row>
<row>
<column name="Notes">Operated as per pm
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027663</column>
</row>
<row>
<column name="Notes">Operated as per pm
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35027664</column>
</row>
<row>
<column name="Notes">Operated as per pm
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027665</column>
</row>
<row>
<column name="Notes">Alarms and trips for MDO operation tested
-OK.</column>
<column name="MaintLogID1">BRMR35027666</column>
</row>
<row>
<column name="Notes">Oil probes operate properly.</column>
<column name="MaintLogID1">BRMR35027667</column>
</row>
<row>
<column name="Notes">Completed as per PM. All equipment in good
condition.</column>
<column name="MaintLogID1">BRMR35027668</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35027669</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35027670</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35027671</column>
</row>
<row>
<column name="Notes">checked all loudspeakers and found 2
loudspeakers damaged . Exchange loudspeakers with spares onboard.
all now working satisfactory.</column>
<column name="MaintLogID1">BRMR35027672</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35027673</column>
</row>
<row>
<column name="Notes">checked visually and found bonding cable to be
in good order.
Brushes not needing to be changed. Sfaft earthing ok.</column>
<column name="MaintLogID1">BRMR35027674</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35027675</column>
</row>
<row>
<column name="Notes">Desiganated valves shut, Cover removed and
leaking joint replaced with new one.
Cover fitted and line put back to normal condition.</column>
<column name="MaintLogID1">BRMR35027676</column>
</row>
<row>
<column name="Notes">Duplicate PM.
Completed 11/07/07</column>
<column name="MaintLogID1">BRMR35027677</column>
</row>
<row>
<column name="Notes">duplicate pm
completed 03/07/07</column>
<column name="MaintLogID1">BRMR35027678</column>
</row>
<row>
<column name="Notes">duplicate pm
completed 11/07/07</column>
<column name="MaintLogID1">BRMR35027679</column>
</row>
<row>
<column name="Notes">duplicate pm
complteted 15/05/07</column>
<column name="MaintLogID1">BRMR35027680</column>
</row>
<row>
<column name="Notes">Duplicate pm
completed 15/05/07</column>
<column name="MaintLogID1">BRMR35027681</column>
</row>
<row>
<column name="Notes">duplicate pm
completed 11/07/07</column>
<column name="MaintLogID1">BRMR35027682</column>
</row>
<row>
<column name="Notes">duplicate pm.
compressor running satisfactory</column>
<column name="MaintLogID1">BRMR35027683</column>
</row>
<row>
<column name="Notes">Line isolated
old gasket removed
replaced with new</column>
<column name="MaintLogID1">BRMR35027684</column>
</row>
<row>
<column name="Notes">tank cleaned out floc amount as whitnessed
previously.
anodes inspected, current correct</column>
<column name="MaintLogID1">BRMR35027685</column>
</row>
<row>
<column name="Notes">tank cleaned out floc amount as whitnessed
previously.
anodes inspected, current correct</column>
<column name="MaintLogID1">BRMR35027686</column>
</row>
<row>
<column name="Notes">pm completed as per work order</column>
<column name="MaintLogID1">BRMR35027687</column>
</row>
<row>
<column name="Notes">Not completed - awaiting spares.</column>
<column name="MaintLogID1">BRMR35027688</column>
</row>
<row>
<column name="Notes">Pressure gauge still on order. Not
completed.</column>
<column name="MaintLogID1">BRMR35027689</column>
</row>
<row>
<column name="Notes">Valve overhauled, pressure tested and
reinstalled.</column>
<column name="MaintLogID1">BRMR35027691</column>
</row>
<row>
<column name="Notes">aft 13.1 fwd 12.1
checked serchlight and found working ok.
battery top clean and terminals in good condition.</column>
<column name="MaintLogID1">BRMR35027692</column>
</row>
<row>
<column name="Notes">aft 12.38 fwd 12.42
checked serchlight and found working ok.
battery top clean and terminals in good condition.
all lights tested and found too be fully functional.</column>
<column name="MaintLogID1">BRMR35027693</column>
</row>
<row>
<column name="Notes">aft 12.23 fwd 12.30
checked serchlight and found working ok.
battery top clean and terminals in good condition.
all lights tested and found too be fully functional.</column>
<column name="MaintLogID1">BRMR35027694</column>
</row>
<row>
<column name="Notes">2.81
2.81
2.91
2.81
battery top clean and terminals in good condition.
System left on floud charger.</column>
<column name="MaintLogID1">BRMR35027695</column>
</row>
<row>
<column name="Notes">2.03 2.03
2.03 2.02
2.02 2.03
2.03 2.03
2.02 2.02
2.03 2.02
23.8V 24.3 A
On discharge battery from 3 hrs.
battery top clean and terminals in good condition.
</column>
<column name="MaintLogID1">BRMR35027696</column>
</row>
<row>
<column name="Notes">2.05 2.06
2.05 2.06
2.05 2.05
2.05 2.05
2.06 2.06
2.07 2.05
24.8V 0.4 A
On discharge battery from 3 hrs.
battery top clean and terminals in good condition.</column>
<column name="MaintLogID1">BRMR35027697</column>
</row>
<row>
<column name="Notes">Details on T:/Engineering Department/JE/Fire
Equipment & Dampers/2007/Fire Extinguishers 2007.xls</column>
<column name="MaintLogID1">BRMR35027698</column>
</row>
<row>
<column name="Notes">All alarms tested and satisfactory</column>
<column name="MaintLogID1">BRMR35027699</column>
</row>
<row>
<column name="Notes">Tested one head in every zone/loop and all
working satisfactory.
</column>
<column name="MaintLogID1">BRMR35027700</column>
</row>
<row>
<column name="Notes">Couldn't be completed due to bad
weather/ship rolling.
To be completed next week</column>
<column name="MaintLogID1">BRMR35027701</column>
</row>
<row>
<column name="Notes">Couldn't be completed due to bad
weather/ship rolling.
To be completed next week</column>
<column name="MaintLogID1">BRMR35027702</column>
</row>
<row>
<column name="Notes">Couldn't be completed due to bad
weather/ship rolling.
To be completed next week</column>
<column name="MaintLogID1">BRMR35027703</column>
</row>
<row>
<column name="Notes">Couldn't be completed due to bad
weather/ship rolling.
To be completed next week</column>
<column name="MaintLogID1">BRMR35027704</column>
</row>
<row>
<column name="Notes">Couldn't be completed due to bad
weather/ship rolling.
To be completed next week</column>
<column name="MaintLogID1">BRMR35027705</column>
</row>
<row>
<column name="Notes">All alarms and trips tested as per job
description.
All found operational within set limits.</column>
<column name="MaintLogID1">BRMR35027706</column>
</row>
<row>
<column name="Notes">Cooler isolated, sea water inlet filter
removed and cleaned.
Cooler backflushed and returned into use.</column>
<column name="MaintLogID1">BRMR35027707</column>
</row>
<row>
<column name="Notes">Cooler in use when no.2 isolated for filter
cleaning.
Backflushed on completion.</column>
<column name="MaintLogID1">BRMR35027708</column>
</row>
<row>
<column name="Notes">Leaking gasket on port boiler sampling line.
Gasket replaced with shelf spare with no AMOS number.</column>
<column name="MaintLogID1">BRMR35027709</column>
</row>
<row>
<column name="Notes">tested in all modes satisfactory</column>
<column name="MaintLogID1">BRMR35027710</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027711</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027712</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027713</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027714</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027715</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027716</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027717</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027718</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027719</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027720</column>
</row>
<row>
<column name="Notes">Boilers on Gas Mode. Cleaning of filter not
necessary.</column>
<column name="MaintLogID1">BRMR35027721</column>
</row>
<row>
<column name="Notes">Unit pumped down and leak tested electric and
saop</column>
<column name="MaintLogID1">BRMR35027732</column>
</row>
<row>
<column name="Notes">Unit pumped down and leak tested electric and
saop</column>
<column name="MaintLogID1">BRMR35027733</column>
</row>
<row>
<column name="Notes">Unit pumped down and leak tested electric and
saop</column>
<column name="MaintLogID1">BRMR35027734</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027735</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027736</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027737</column>
</row>
<row>
<column name="Notes">main pump this week
all valves operated</column>
<column name="MaintLogID1">BRMR35027738</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027739</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027740</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027741</column>
</row>
<row>
<column name="Notes">lubricated</column>
<column name="MaintLogID1">BRMR35027742</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027743</column>
</row>
<row>
<column name="Notes">operated</column>
<column name="MaintLogID1">BRMR35027744</column>
</row>
<row>
<column name="Notes">Tested elevator alarm and sounding ok in
engine room and also on bridge.
Tested automatic telephone and working good.
Tested sound powered telephone and found to be working.
</column>
<column name="MaintLogID1">BRMR35027745</column>
</row>
<row>
<column name="Notes">Rudder angle checked with the indicator on the
bridge and found to be accurate.</column>
<column name="MaintLogID1">BRMR35027746</column>
</row>
<row>
<column name="Notes">All outside lights left on for four hours. Low
insulatioln indication which has to be investigated.
Found one floodlight out which has to be replaced. Aft mooring port side
lower.
</column>
<column name="MaintLogID1">BRMR35027747</column>
</row>
<row>
<column name="Notes">All alrms tested and found to be working
satisfactory</column>
<column name="MaintLogID1">BRMR35027748</column>
</row>
<row>
<column name="Notes">All alarms tested and found to be fully
functional</column>
<column name="MaintLogID1">BRMR35027749</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027750</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027751</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027752</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027753</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027754</column>
</row>
<row>
<column name="Notes">Tested two areas route 14 and 15 and found all
detector heads operating correctly and also the
manual call points. System powered down and reset after testing was
completed. Power back on and
system fully functional.</column>
<column name="MaintLogID1">BRMR35027755</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027756</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35027757</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027758</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.</column>
<column name="MaintLogID1">BRMR35027759</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027760</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027761</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027762</column>
</row>
<row>
<column name="Notes">Crane greased as per pm. Entire crane given
full coat of paint.
all limits operational.</column>
<column name="MaintLogID1">BRMR35027763</column>
</row>
<row>
<column name="Notes">Crane greased as per pm.. Sight glass on
slewing gearbox was found to be siliconed up and was weeping oil.
Blank was fitted to prevent weeping. Sight glass for oil still ok on aft
end of gearbox.</column>
<column name="MaintLogID1">BRMR35027764</column>
</row>
<row>
<column name="Notes">Resuscepac from Hospital . satisfactory.
Resuecepac from Team 1 still ashore for repair.</column>
<column name="MaintLogID1">BRMR35027765</column>
</row>
<row>
<column name="Notes">All parts greased as per pm. Some scale was
removed from guillotine as it was starting to rub making
lever difficult to lift.</column>
<column name="MaintLogID1">BRMR35027766</column>
</row>
<row>
<column name="Notes">All parts greased as per pm. Some scale was
removed from guillotine as it was starting to rub making
lever difficult to lift.</column>
<column name="MaintLogID1">BRMR35027767</column>
</row>
<row>
<column name="Notes">all bilge alarms tested satis</column>
<column name="MaintLogID1">BRMR35027768</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027769</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027770</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027771</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027772</column>
</row>
<row>
<column name="Notes">pm comleted as per work order.ok</column>
<column name="MaintLogID1">BRMR35027773</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027774</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027775</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok.Turn
compressor by hand,sump heater functioning correctly.</column>
<column name="MaintLogID1">BRMR35027776</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok.Turn
compressor by hand,sump heater functioning correctly.</column>
<column name="MaintLogID1">BRMR35027777</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Turn compressor
by hand,sump heater functioning correctly.</column>
<column name="MaintLogID1">BRMR35027778</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Turn compressor
by hand,sumpheater functioning correctly.</column>
<column name="MaintLogID1">BRMR35027779</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Positioner
drive shaft lubricate with WD40.</column>
<column name="MaintLogID1">BRMR35027780</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Positioner
drive shaft lubricated with WD40.</column>
<column name="MaintLogID1">BRMR35027781</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Positioner
drive shaft lubricated with WD40.</column>
<column name="MaintLogID1">BRMR35027782</column>
</row>
<row>
<column name="Notes">pm completed as per work order.Positioner
drive shaft lubricated with WD40.</column>
<column name="MaintLogID1">BRMR35027783</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35027784</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35027785</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35027786</column>
</row>
<row>
<column name="Notes">tested satisfactory by third officer.</column>
<column name="MaintLogID1">BRMR35027787</column>
</row>
<row>
<column name="Notes">Checked rudder angle with repeater unit on
bridge and found to be accurate.</column>
<column name="MaintLogID1">BRMR35027788</column>
</row>
<row>
<column name="Notes">Checked Loran C and powered uip ok unable to
check operation as out of range for signal.</column>
<column name="MaintLogID1">BRMR35027789</column>
</row>
<row>
<column name="Notes">Checked clocks with master clock and and all
accurate.</column>
<column name="MaintLogID1">BRMR35027790</column>
</row>
<row>
<column name="Notes">All lightsticks found in place and in good
condition. All satisfactory</column>
<column name="MaintLogID1">BRMR35027791</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35027792</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35027793</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35027794</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35027795</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35027796</column>
</row>
<row>
<column name="Notes">Compressor's oil drained and refilled
with 55 liters of ENERSYN RC-S68.
Oil filter changed.
Running hours 12759.</column>
<column name="MaintLogID1">BRMR35027797</column>
</row>
<row>
<column name="Notes">Greased as per instructions for
merchant</column>
<column name="MaintLogID1">BRMR35027798</column>
</row>
<row>
<column name="Notes">all bilge alarms tested satis</column>
<column name="MaintLogID1">BRMR35027799</column>
</row>
<row>
<column name="Notes">port fwd isolator on trunk deck, was tight and
needed overhaul.
Valve was removed and taken to ER workshop for overhaul. The Spindle was
seized tight in the gland
and required considerable force knocking it out. The valve was overhauled
and reassembled by cargo eng.
The valve was replaced and tested. The extended spindle connecting cross
pins required drilling out prior to removal, new
pins were fabricated. While the valve was out, the faces inside the valve
body were cleaned up.
There was a lot of build up on the faces, that required removal.</column>
<column name="MaintLogID1">BRMR35027800</column>
</row>
<row>
<column name="Notes">all equipment was in order as per the list on
the PM</column>
<column name="MaintLogID1">BRMR35027801</column>
</row>
<row>
<column name="Notes">all isolators operated. port fwd isolator
stiff. needs overhaul.</column>
<column name="MaintLogID1">BRMR35027802</column>
</row>
<row>
<column name="Notes">hoses tested as per week 1rota. all
satis</column>
<column name="MaintLogID1">BRMR35027803</column>
</row>
<row>
<column name="Notes">hoses tested as per week 1rota. all
satis</column>
<column name="MaintLogID1">BRMR35027804</column>
</row>
<row>
<column name="Notes">checked two transponder (SART)
-port Sart ok
-strb Sart no operated, new battery on order</column>
<column name="MaintLogID1">BRMR35027805</column>
</row>
<row>
<column name="Notes">Visually inspected and found to be operated
satisfactory.
</column>
<column name="MaintLogID1">BRMR35027806</column>
</row>
<row>
<column name="Notes">checked and cleaned dial window.
No audible alarms, binnacle is free in its shock mounts.
All screws on binnacle covers secure.
No clean compass and transmitters required.
Alignment is good</column>
<column name="MaintLogID1">BRMR35027807</column>
</row>
<row>
<column name="Notes">checked and cleaned dial window.
No audible alarms, binnacle is free in its shock mounts.
All screws on binnacle covers secure.
No clean compass and transmitters required.
Alignment is good</column>
<column name="MaintLogID1">BRMR35027808</column>
</row>
<row>
<column name="Notes">Visually inspect and found operation
satisfactory.</column>
<column name="MaintLogID1">BRMR35027809</column>
</row>
<row>
<column name="Notes">Visually inspect and found operation
satisfactory.</column>
<column name="MaintLogID1">BRMR35027810</column>
</row>
<row>
<column name="Notes">230 230 230 230 230 230
218 229 228 218 229 228 230.3 230.3
230.6 230.6 12.4 12.4 12.5 12.5 220 216
104 104 104 103.4 103.3 103.2 All Batteries
in good condition.
Checked individual batteries on UPS 5 and 6 and all cells in good
condition.
</column>
<column name="MaintLogID1">BRMR35027811</column>
</row>
<row>
<column name="Notes">Done as per PM.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027812</column>
</row>
<row>
<column name="Notes">Done as per PM.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027813</column>
</row>
<row>
<column name="Notes">Void space under Electricians Workshop :
Inspected by C/O and 2/E. All cabling secure. No signs of leaking pipework.
No signs of cracking or deformation.
Coatings all intact.
</column>
<column name="MaintLogID1">BRMR35027824</column>
</row>
<row>
<column name="Notes">Duplicate PM
Last separator change 11508 hrs.
Current running hrs 12422.
Separator change not due for another 2000 hrs.</column>
<column name="MaintLogID1">BRMR35027825</column>
</row>
<row>
<column name="Notes">Duplicate PM
Last oil and filter change 11508 hrs.
Current running hours 12422.
Oil change not due for another 1000 hrs.</column>
<column name="MaintLogID1">BRMR35027826</column>
</row>
<row>
<column name="Notes">Duplicate PM
Completed 03/07/07.
Motor greasing not due for another 1639 hrs.(frequency 2000 hrs).
</column>
<column name="MaintLogID1">BRMR35027827</column>
</row>
<row>
<column name="Notes">Duplicate PM.
Completed togethetr with alarms and trips on 11/07/07.
Compressor's current running hours 12422. (only 361 running hours
since beginning of July).
</column>
<column name="MaintLogID1">BRMR35027828</column>
</row>
<row>
<column name="Notes">Damper for N3 ER supply fan found stiff, flap
bearings greased, free movement restored, checked in operation
-OK.</column>
<column name="MaintLogID1">BRMR35027829</column>
</row>
<row>
<column name="Notes">Free to turn by hand</column>
<column name="MaintLogID1">BRMR35027831</column>
</row>
<row>
<column name="Notes">Valves operated</column>
<column name="MaintLogID1">BRMR35027839</column>
</row>
<row>
<column name="Notes">tested all ok</column>
<column name="MaintLogID1">BRMR35027840</column>
</row>
<row>
<column name="Notes">Main pump this week so all valves operated
pump only spun</column>
<column name="MaintLogID1">BRMR35027841</column>
</row>
<row>
<column name="Notes">inspected</column>
<column name="MaintLogID1">BRMR35027842</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027843</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027844</column>
</row>
<row>
<column name="Notes">system checked with gas and electric
meter</column>
<column name="MaintLogID1">BRMR35027845</column>
</row>
<row>
<column name="Notes">all functions tested and satisfactory</column>
<column name="MaintLogID1">BRMR35027846</column>
</row>
<row>
<column name="Notes">all tested and satisfactory, recorded official
log book</column>
<column name="MaintLogID1">BRMR35027847</column>
</row>
<row>
<column name="Notes">system checked with gas and electric
meter.unit ran pumped down no defects</column>
<column name="MaintLogID1">BRMR35027848</column>
</row>
<row>
<column name="Notes">system checked with gas and electric meter.
unit ran and pumped down no defects</column>
<column name="MaintLogID1">BRMR35027849</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027850</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027851</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027852</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027853</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027854</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027855</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027856</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027857</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027858</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027859</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027860</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027861</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027862</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027863</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027864</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027865</column>
</row>
<row>
<column name="Notes">Damaged drive belts replaced with new ones.
Running hours 12762.
</column>
<column name="MaintLogID1">BRMR35027866</column>
</row>
<row>
<column name="Notes">Ballast tank vent mesh size checked and
confirmed fitted as per makers manual (30 mesh)</column>
<column name="MaintLogID1">BRMR35027867</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027868</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027869</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027870</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027871</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027872</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027873</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35027874</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027875</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027876</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027877</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027878</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027879</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027880</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027881</column>
</row>
<row>
<column name="Notes">pm completed as per work order.turn compressor
by hand,sump heater functioning correctly.ok</column>
<column name="MaintLogID1">BRMR35027882</column>
</row>
<row>
<column name="Notes">pm completed as per work order.turn compressor
by hand,sump heater functioning correctly.ok</column>
<column name="MaintLogID1">BRMR35027883</column>
</row>
<row>
<column name="Notes">pm completed as per work order.turn compressor
by hand,sump heater functioning correctly.ok</column>
<column name="MaintLogID1">BRMR35027884</column>
</row>
<row>
<column name="Notes">pm completed as per work order.turn compressor
by hand,sump heater functioning correctly.ok</column>
<column name="MaintLogID1">BRMR35027885</column>
</row>
<row>
<column name="Notes">pm completed as per work order.lubricate
positioner drve shaft with WD40.ok</column>
<column name="MaintLogID1">BRMR35027886</column>
</row>
<row>
<column name="Notes">pm completed as per work order.lubricated
positioner drive shaft with WD40.ok </column>
<column name="MaintLogID1">BRMR35027887</column>
</row>
<row>
<column name="Notes">pm completed as per work order.lubricated
positioner drive shaft with WD40.ok</column>
<column name="MaintLogID1">BRMR35027888</column>
</row>
<row>
<column name="Notes">pm completed as per work order.lubricated
positiner drive shaft with WD40.ok</column>
<column name="MaintLogID1">BRMR35027889</column>
</row>
<row>
<column name="Notes">pm completed as per work order.ok</column>
<column name="MaintLogID1">BRMR35027890</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35027891</column>
</row>
<row>
<column name="Notes">pm completed as per work order.</column>
<column name="MaintLogID1">BRMR35027892</column>
</row>
<row>
<column name="Notes">Checked alarm and working good.
Checked telephones and all operating</column>
<column name="MaintLogID1">BRMR35027893</column>
</row>
<row>
<column name="Notes">Checked rudder angle indicator with bridge and
reading accurately.</column>
<column name="MaintLogID1">BRMR35027894</column>
</row>
<row>
<column name="Notes">Checked call alarms and both
operating.</column>
<column name="MaintLogID1">BRMR35027895</column>
</row>
<row>
<column name="Notes">Checked alarms and both operating</column>
<column name="MaintLogID1">BRMR35027896</column>
</row>
<row>
<column name="Notes">Checked all lights outdoors and changed
ignitor on fwd facing port floodlight, working ok now.</column>
<column name="MaintLogID1">BRMR35027897</column>
</row>
<row>
<column name="Notes">Tested zones 16 and 17 successfully, all heads
and call points fully operational.</column>
<column name="MaintLogID1">BRMR35027898</column>
</row>
<row>
<column name="Notes">Checked satus of VDR and status indicated
ok.</column>
<column name="MaintLogID1">BRMR35027899</column>
</row>
<row>
<column name="Notes">All isolators operated satisfactorily</column>
<column name="MaintLogID1">BRMR35027900</column>
</row>
<row>
<column name="Notes">Week 2 hoses tested satis</column>
<column name="MaintLogID1">BRMR35027901</column>
</row>
<row>
<column name="Notes">Wk 2hoses tested satis</column>
<column name="MaintLogID1">BRMR35027902</column>
</row>
<row>
<column name="Notes">All vent drains checked, and drained of water
by cargo eng.</column>
<column name="MaintLogID1">BRMR35027903</column>
</row>
<row>
<column name="Notes">ETA checked ok. light tested satis.</column>
<column name="MaintLogID1">BRMR35027904</column>
</row>
<row>
<column name="Notes">spaces checked. bilge alarms tested
ok</column>
<column name="MaintLogID1">BRMR35027905</column>
</row>
<row>
<column name="Notes">spaces checked bilge alarms tested ok</column>
<column name="MaintLogID1">BRMR35027906</column>
</row>
<row>
<column name="Notes">Filters inspected, found clean.</column>
<column name="MaintLogID1">BRMR35027907</column>
</row>
<row>
<column name="Notes">Filters inspected, found clean.</column>
<column name="MaintLogID1">BRMR35027908</column>
</row>
<row>
<column name="Notes">All out of date bottles replaced. All out of
date eye pads replaced.
Bottles replaced in:
3rd deck workshop
purifier room
stbd evap
</column>
<column name="MaintLogID1">BRMR35027915</column>
</row>
<row>
<column name="Notes">All satisfactory except one lifejacket cosalt
premier with torn waist belt and one inflatable lifejacket with light not
working. Order
for new lifejacket sent, also order for new lights for inflatable
lifejackets sent.</column>
<column name="MaintLogID1">BRMR35027916</column>
</row>
<row>
<column name="Notes">All satisfactory except bracket for fire
extinguisher which is rusted. Fitter to fabricate new one. Boat fresh water
washed.</column>
<column name="MaintLogID1">BRMR35027917</column>
</row>
<row>
<column name="Notes">All satisfactory. Lights for lifebuoys on
order.</column>
<column name="MaintLogID1">BRMR35027918</column>
</row>
<row>
<column name="Notes">Inspection made as per PM. All found
satisfactory.</column>
<column name="MaintLogID1">BRMR35027919</column>
</row>
<row>
<column name="Notes">greased and inspected</column>
<column name="MaintLogID1">BRMR35027920</column>
</row>
<row>
<column name="Notes">greased and inspected</column>
<column name="MaintLogID1">BRMR35027921</column>
</row>
<row>
<column name="Notes">greased and inspected</column>
<column name="MaintLogID1">BRMR35027922</column>
</row>
<row>
<column name="Notes">inspected and cleaned</column>
<column name="MaintLogID1">BRMR35027923</column>
</row>
<row>
<column name="Notes">greased and inspected</column>
<column name="MaintLogID1">BRMR35027924</column>
</row>
<row>
<column name="Notes">Water spray system tested satisfactorily. A
couple of nozzles required prodding whilst in operation to clear them.
One nozzle on accommodation front completly blocked. It was removed and
cleared.
Debris blocking the nozzle looked like shell deposits and scale.
All valves were operated on the system and proved satisfactory.
System drained after test.</column>
<column name="MaintLogID1">BRMR35027925</column>
</row>
<row>
<column name="Notes">Water spray system tested satisfactory.
There were approximatley 20 nozzles thatrequired removal and clearing.
Theblockages appear to be shell deposits.
Both manifolds had all nozzles removed and cleared. No 3 vapor dome had
three nozzles remived and cleared.
No 1 liquid dome had 2 nozzles removed and cleared.
There were also a few around the top of the gas house that required
unblocking.
all of the valves operated satisfactorily.
the system was drained after use.
</column>
<column name="MaintLogID1">BRMR35027926</column>
</row>
<row>
<column name="Notes">lubricated and inspected</column>
<column name="MaintLogID1">BRMR35027927</column>
</row>
<row>
<column name="Notes">lubricated and inspected</column>
<column name="MaintLogID1">BRMR35027928</column>
</row>
<row>
<column name="Notes">lubricated and inspected</column>
<column name="MaintLogID1">BRMR35027929</column>
</row>
<row>
<column name="Notes">lubricated and inspected</column>
<column name="MaintLogID1">BRMR35027930</column>
</row>
<row>
<column name="Notes">lubricated and inspected.
operated</column>
<column name="MaintLogID1">BRMR35027931</column>
</row>
<row>
<column name="Notes">operation confirmed</column>
<column name="MaintLogID1">BRMR35027932</column>
</row>
<row>
<column name="Notes">standby pump this week ran on aux condenser
all valves operated</column>
<column name="MaintLogID1">BRMR35027933</column>
</row>
<row>
<column name="Notes">inspection carried out</column>
<column name="MaintLogID1">BRMR35027934</column>
</row>
<row>
<column name="Notes">tested</column>
<column name="MaintLogID1">BRMR35027935</column>
</row>
<row>
<column name="Notes">flushed</column>
<column name="MaintLogID1">BRMR35027936</column>
</row>
<row>
<column name="Notes">Carried out using electric meter gas &
soap
pump down carried out no defects observed</column>
<column name="MaintLogID1">BRMR35027937</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027938</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027939</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027940</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027941</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027942</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027943</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027944</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027945</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027946</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027947</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027948</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027949</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027950</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027951</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027952</column>
</row>
<row>
<column name="Notes">Completed as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35027953</column>
</row>
<row>
<column name="Notes">Rescue boat launched at anchorage Point Fortin
Trinidad all Satisfactory</column>
<column name="MaintLogID1">BRMR35027954</column>
</row>
<row>
<column name="Notes">All test and satisfactory notice recieved from
BP confirming test</column>
<column name="MaintLogID1">BRMR35027955</column>
</row>
<row>
<column name="Notes">All tested and satisfactory</column>
<column name="MaintLogID1">BRMR35027956</column>
</row>
<row>
<column name="Notes">all fairleads greased and moved
satisfactorily.
All fairleads have been descaled and painted on the rollers over the last
month.</column>
<column name="MaintLogID1">BRMR35027957</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027958</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027959</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027960</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027961</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027962</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027963</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027964</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027965</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027966</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027967</column>
</row>
<row>
<column name="Notes">all winches greased and operated
satisfactory.</column>
<column name="MaintLogID1">BRMR35027968</column>
</row>
<row>
<column name="Notes">The following ballast tank vents had there
screens replaced due to splits in the old screens
4S (Fwd)
3SF (Fwd)
3SF (Aft)
2S (Fwd)
FP (P)
2PF (Fwd)
3PF (Fwd)
ERP (Fwd)</column>
<column name="MaintLogID1">BRMR35027969</column>
</row>
<row>
<column name="Notes">Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.
During there last use at Trinidad it was noted that there was a lot of
water in the air supply.
To drain the line involved removing the hoses and blasting out for a
considerable time.
As some water will have inevitably been carried over to the moment . the
motors have been flushed with oil.
</column>
<column name="MaintLogID1">BRMR35027970</column>
</row>
<row>
<column name="Notes">Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.
During there last use at Trinidad it was noted that there was a lot of
water in the air supply.
To drain the line involved removing the hoses and blasting out for a
considerable time.
As some water will have inevitably been carried over to the moment . the
motors have been flushed with oil.</column>
<column name="MaintLogID1">BRMR35027971</column>
</row>
<row>
<column name="Notes">Accomodation ladder inspected and found
satisfactory. All parts greased
As noted in the air motor history:-
Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.
During there last use at Trinidad it was noted that there was a lot of
water in the air supply.
To drain the line involved removing the hoses and blasting out for a
considerable time.
As some water will have inevitably been carried over to the moment . the
motors have been flushed with oil.</column>
<column name="MaintLogID1">BRMR35027972</column>
</row>
<row>
<column name="Notes">Accomodation ladder inspected and found
satisfactory. All parts greased
As noted in the air motor history:-
Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.
During there last use at Trinidad it was noted that there was a lot of
water in the air supply.
To drain the line involved removing the hoses and blasting out for a
considerable time.
As some water will have inevitably been carried over to the moment . the
motors have been flushed with oil.</column>
<column name="MaintLogID1">BRMR35027973</column>
</row>
<row>
<column name="Notes">all flaps greased.all doors greased.
doors on stbd aft of er casing had ther packing reomved and channels
descaled and painted.
hatches for UDPP on port side had there packing removed and descaled and
painted.</column>
<column name="MaintLogID1">BRMR35027974</column>
</row>
<row>
<column name="Notes">Harnesses and lanyards inspected ok. Some of
the safety lines were removed from service and
replaced due to oil impregnation.</column>
<column name="MaintLogID1">BRMR35027975</column>
</row>
<row>
<column name="Notes">all isolators operated through full
travel.</column>
<column name="MaintLogID1">BRMR35027976</column>
</row>
<row>
<column name="Notes">Hose tests carried out as per wk 3
schedule</column>
<column name="MaintLogID1">BRMR35027977</column>
</row>
<row>
<column name="Notes">hose tests carried out as per wk 3
scedule</column>
<column name="MaintLogID1">BRMR35027978</column>
</row>
<row>
<column name="Notes">Tested elevator alarm and sounding ok in
engine room and also on bridge.
Tested automatic telephone and working good.
Tested sound powered telephone and found to be working.
</column>
<column name="MaintLogID1">BRMR35027979</column>
</row>
<row>
<column name="Notes">Checked rudder angle indicator with bridge and
reading accurately.</column>
<column name="MaintLogID1">BRMR35027980</column>
</row>
<row>
<column name="Notes">Tested zones 18 and 19 successfully, all heads
and call points fully operational.</column>
<column name="MaintLogID1">BRMR35027981</column>
</row>
<row>
<column name="Notes">This PM is completed by the Engine room crew
as part of the saterday routines.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027982</column>
</row>
<row>
<column name="Notes">Checked call alarms and both
operating.</column>
<column name="MaintLogID1">BRMR35027983</column>
</row>
<row>
<column name="Notes">Checked call alarms and both
operating.</column>
<column name="MaintLogID1">BRMR35027984</column>
</row>
<row>
<column name="Notes">Operated all shipside v/v's that are not
is regular use. All v/v spindles were well lubricated and
free to move.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027985</column>
</row>
<row>
<column name="Notes">Completed as per Pm.
Lights on for 6 hrs.
Insulation OK.</column>
<column name="MaintLogID1">BRMR35027986</column>
</row>
<row>
<column name="Notes">All machinery listed on PM, were rotated by
hand. First ensureing the stop button
was in the lock position.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027987</column>
</row>
<row>
<column name="Notes">Station to 003669998 from 23567300
on 4267.5 KHZ Acknowledged received.</column>
<column name="MaintLogID1">BRMR35027988</column>
</row>
<row>
<column name="Notes">Motor changed in scanner unit for new spare
motor.
Old motor taken down stripped cleaned and bearings replaced with new.
Original brushes in good condtion so no need to exchange.
This motor stored in D deck electronic room as spare.</column>
<column name="MaintLogID1">BRMR35027989</column>
</row>
<row>
<column name="Notes">The stop button on the S/G water spray p/p
was locked in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027990</column>
</row>
<row>
<column name="Notes">The stop button on the Fire p/p was locked in
the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027991</column>
</row>
<row>
<column name="Notes">The stop button on the no1 G/S p/p was locked
in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027992</column>
</row>
<row>
<column name="Notes">The stop button on the no2 G/S p/p was locked
in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027993</column>
</row>
<row>
<column name="Notes">The stop button on the no3 ballast p/p was
locked in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The water tank was then topped up with water.
The machinery was then returned to standby condition.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027994</column>
</row>
<row>
<column name="Notes">The ppm monitor was tested, as per the
instructions on the PM. There was no need for
recalibrationof the unit. The desiccator does not need replacing as yet.
BR x4/e</column>
<column name="MaintLogID1">BRMR35027995</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35027996</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35027997</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35027998</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35027999</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35028000</column>
</row>
<row>
<column name="Notes">Burner replaced with clean one.
Removed burner to be cleaned.
</column>
<column name="MaintLogID1">BRMR35028001</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35028002</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35028003</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine. Fire main
pressure 0.9 MPa.</column>
<column name="MaintLogID1">BRMR35028004</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35028005</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35028006</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine.</column>
<column name="MaintLogID1">BRMR35028007</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine together with
on load test.</column>
<column name="MaintLogID1">BRMR35028008</column>
</row>
<row>
<column name="Notes">Photo resistor was removed and cleaned with a
damp cloth.
The Incinerator had been recently cleaned and all inlets were free of
obstruction.
BR x4/e</column>
<column name="MaintLogID1">BRMR35028009</column>
</row>
<row>
<column name="Notes">Crane wire greased , no defects noted. Wire in
good condition.
All grease points greased. Crane run on test all limits satis</column>
<column name="MaintLogID1">BRMR35028010</column>
</row>
<row>
<column name="Notes">space checked . bilge alarms ok</column>
<column name="MaintLogID1">BRMR35028011</column>
</row>
<row>
<column name="Notes">space checked . bilge alarms ok</column>
<column name="MaintLogID1">BRMR35028012</column>
</row>
<row>
<column name="Notes">Filter unit replaced
calibration carried out</column>
<column name="MaintLogID1">BRMR35028013</column>
</row>
<row>
<column name="Notes">Em'cy Generator on load test completed,
all sequence satisfactory.
Em'cy transformers changed over.</column>
<column name="MaintLogID1">BRMR35028014</column>
</row>
<row>
<column name="Notes">Auxy Feed Pump run on test during main feed
pumps change over.
All satisfactory.
Suction strainer inspected, cover o-ring renewed.</column>
<column name="MaintLogID1">BRMR35028015</column>
</row>
<row>
<column name="Notes">No 2 evaporator ejector nozzles found worn
out.
After receiving spares nozzle 2 and 3 (brass ones) replaced.
Nozzle 1 (stainless) found in good order.
Evap run on test, satisfactory.</column>
<column name="MaintLogID1">BRMR35028016</column>
</row>
<row>
<column name="Notes">Checked the operation of the system and
working satisfactory. All illuminations correct.</column>
<column name="MaintLogID1">BRMR35028017</column>
</row>
<row>
<column name="Notes">Intermittent fault where Nr2 GPS does not
display any course or speed or data or psn, this clears
after a few hours and then the system works ok for a few days.</column>
<column name="MaintLogID1">BRMR35028018</column>
</row>
<row>
<column name="Notes">System working satisfactory.</column>
<column name="MaintLogID1">BRMR35028019</column>
</row>
<row>
<column name="Notes">System operating satisfactory.</column>
<column name="MaintLogID1">BRMR35028020</column>
</row>
<row>
<column name="Notes">System is tested on a weekly basis and found
to be fully functional.</column>
<column name="MaintLogID1">BRMR35028021</column>
</row>
<row>
<column name="Notes">Sytem fully operational and no faults
reported.</column>
<column name="MaintLogID1">BRMR35028022</column>
</row>
<row>
<column name="Notes">System not functioning properly, only reading
wind direction from the port side.
Climbed mast and inspected the photo sensors, cleaned and tested system by
rotating to the
starboard side but system still only indicating direction from the port
side. Further investigation
on electronic reciever pending.
</column>
<column name="MaintLogID1">BRMR35028023</column>
</row>
<row>
<column name="Notes">V-belts found worn.
Replaced with new set.
All satisfactory.
</column>
<column name="MaintLogID1">BRMR35028024</column>
</row>
<row>
<column name="Notes">Fuses turned off for 30 min as in pm
instruction.
Chacked batteries.
Two emergency lamps don't work.
</column>
<column name="MaintLogID1">BRMR35028103</column>
</row>
<row>
<column name="Notes">Work carried out in conjunction with
ETO's PM.
Belts in good condition. All secure. No leaks found.</column>
<column name="MaintLogID1">BRMR35028104</column>
</row>
<row>
<column name="Notes">D/G FO supply filter cleaned.
D/G FO fine filter No 2 cartridges changed.
D/G tested, all satisfactory.
Running hours: 1904.</column>
<column name="MaintLogID1">BRMR35028105</column>
</row>
<row>
<column name="Notes">After receiving o/h kits (not on AMOS) both
phosphate dosing pumps overhauled.
Pumps tested, vented, found satisfactory.</column>
<column name="MaintLogID1">BRMR35028106</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028107</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028108</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028109</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028110</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028111</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028112</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.
Bridge fire main pressure 9 bar.</column>
<column name="MaintLogID1">BRMR35028113</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028114</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028115</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028116</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028117</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028118</column>
</row>
<row>
<column name="Notes">All carried out as per work order. No defects
observed, strobe light tested and working correctly.
</column>
<column name="MaintLogID1">BRMR35028119</column>
</row>
<row>
<column name="Notes">All completed as per work order. No defects
observed.
L.E. West spreadsheet updated as required.
</column>
<column name="MaintLogID1">BRMR35028120</column>
</row>
<row>
<column name="Notes">Completed as per work order.
No defects observed.</column>
<column name="MaintLogID1">BRMR35028121</column>
</row>
<row>
<column name="Notes">High level alarm tested &
operational.</column>
<column name="MaintLogID1">BRMR35028122</column>
</row>
<row>
<column name="Notes">High level alarm tested &
operational.</column>
<column name="MaintLogID1">BRMR35028123</column>
</row>
<row>
<column name="Notes">High level alarm tested &
operational.</column>
<column name="MaintLogID1">BRMR35028124</column>
</row>
<row>
<column name="Notes">Gland steam make-up control v/v joint renewed
(after control valve.)
LP turbine gland steam flange joint at NDE of LP turbine casing
renewed.</column>
<column name="MaintLogID1">BRMR35028125</column>
</row>
<row>
<column name="Notes">Carried out in conjunction with ETO's PM.
Belts checked, tensions satisfactory.
Fittings secure.
No refrigerant leaks detected.</column>
<column name="MaintLogID1">BRMR35028126</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Cleaned contacotrs. Checked all cableing and found in good order. Checked
all connections
and all secure.
Insulation readings for fan and compressor > 100 megs
</column>
<column name="MaintLogID1">BRMR35028127</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Cleaned contacotrs. Checked all cableing and found in good order. Checked
all connections
and all secure.
Insulation readings for fan and compressor > 100 megs</column>
<column name="MaintLogID1">BRMR35028128</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Cleaned contacotrs. Checked all cableing and found in good order. Checked
all connections
and all secure.
Insulation readings for fan and compressor > 100 megs</column>
<column name="MaintLogID1">BRMR35028129</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Cleaned contacotrs. Checked all cableing and found in good order. Checked
all connections
and all secure.
Insulation readings for fan and compressor > 100 megs</column>
<column name="MaintLogID1">BRMR35028130</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Cleaned contacotrs. Checked all cableing and found in good order. Checked
all connections
and all secure.
Insulation readings for fan and compressor > 100 megs</column>
<column name="MaintLogID1">BRMR35028131</column>
</row>
<row>
<column name="Notes">Loading computer test conditions compared and
no abnormalities observed.</column>
<column name="MaintLogID1">BRMR35028132</column>
</row>
<row>
<column name="Notes">This unit does not exist on this
vessel</column>
<column name="MaintLogID1">BRMR35028133</column>
</row>
<row>
<column name="Notes">VHF DSC internal tests carried out and found
to be fully operational. All lights working good.
System reported to be working well in transmission and reception.</column>
<column name="MaintLogID1">BRMR35028134</column>
</row>
<row>
<column name="Notes">Recieving well all relevant communications.
All lights and systems operating satisfactory.</column>
<column name="MaintLogID1">BRMR35028135</column>
</row>
<row>
<column name="Notes">VHF DSC internal tested and found to be fully
functional. All lights operating satisfactory.
Reported to be transmitting and recieving satistactory.</column>
<column name="MaintLogID1">BRMR35028136</column>
</row>
<row>
<column name="Notes">VHF DSC internal tested and found to be fully
functional. All lights found to be working satisfactory.
Reported to be transmitting and recieving satisfactory.</column>
<column name="MaintLogID1">BRMR35028137</column>
</row>
<row>
<column name="Notes">Internal DSC working satisfactory. All lights
found to be fully functional.
Reported to be transmitting and recieving satisfactory.</column>
<column name="MaintLogID1">BRMR35028138</column>
</row>
<row>
<column name="Notes">pm completed as per work order.splindles lubed
and operetad by hand,spray and liquid v/vs greased.ok</column>
<column name="MaintLogID1">BRMR35028139</column>
</row>
<row>
<column name="Notes">pm completed as per work order.manual valves
checked, turn by hand.ok</column>
<column name="MaintLogID1">BRMR35028140</column>
</row>
<row>
<column name="Notes">pm completed as per work order.IBS/IS spaces
measured for LEL andO2 used portable analyser.ok</column>
<column name="MaintLogID1">BRMR35028141</column>
</row>
<row>
<column name="Notes">pm completed as per work order.IBS/IS spaces
measured for LEL and O2 used portable analyser.ok</column>
<column name="MaintLogID1">BRMR35028142</column>
</row>
<row>
<column name="Notes">pm completed as per work order.IBS/IS spaces
measured for LEL and O2,used portable analyser.ok</column>
<column name="MaintLogID1">BRMR35028143</column>
</row>
<row>
<column name="Notes">pm completed as per work order.IBS/IS spaces
mesured for LELandO2 used portable analyser.ok</column>
<column name="MaintLogID1">BRMR35028144</column>
</row>
<row>
<column name="Notes">pm completed as per work order.fan housing and
fastening condition checked,retight bolts,checked for any abnormal
noise.ok</column>
<column name="MaintLogID1">BRMR35028145</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok</column>
<column name="MaintLogID1">BRMR35028146</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok</column>
<column name="MaintLogID1">BRMR35028147</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok</column>
<column name="MaintLogID1">BRMR35028148</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok </column>
<column name="MaintLogID1">BRMR35028149</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok</column>
<column name="MaintLogID1">BRMR35028150</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok </column>
<column name="MaintLogID1">BRMR35028151</column>
</row>
<row>
<column name="Notes">pm completed as per work order.condition of
fan housing and fastenings checked,retight bolts,for any abnormal noise
checked.ok</column>
<column name="MaintLogID1">BRMR35028152</column>
</row>
<row>
<column name="Notes">Maintenance carried out as per work order. All
fairleads and rollers proved free.
No defects observed.
</column>
<column name="MaintLogID1">BRMR35028153</column>
</row>
<row>
<column name="Notes">Boat lowered to water and run on test for
approx 20mins. water spray tested satis.
Boat was launched , tested and recovered without incident.</column>
<column name="MaintLogID1">BRMR35028154</column>
</row>
<row>
<column name="Notes">Boat lowered to water and run on test for
approx 20mins. water spray tested satis.
Boat was launched , tested and recovered without incident.</column>
<column name="MaintLogID1">BRMR35028155</column>
</row>
<row>
<column name="Notes">Condenser opened up and inspected. SW inlet
side tubeplate found in good condition and clear of debris
or marine growth.
Tube plate cleaned. Anodes inspected - these will last until drydock, but
must be renewed there.
Scoop MGPS anodes inspected and will last until drydock.
Tubes cleared using tube cleaning brushes ( as many as time would allow.
Approx 20%, starting
at exhaust side of condenser.)</column>
<column name="MaintLogID1">BRMR35028156</column>
</row>
<row>
<column name="Notes">Condenser opened up and inspected. SW inlet
side tubeplate found in good condition and clear of debris
or marine growth.
Tube plate cleaned. Anodes inspected - these will last until drydock, but
must be renewed there.
Scoop MGPS anodes inspected and will last until drydock.
Tubes cleaned using tube cleaning brushes ( as many as time would allow.
Approx 20%, starting
at exhaust side of condenser.)
</column>
<column name="MaintLogID1">BRMR35028178</column>
</row>
<row>
<column name="Notes">All valves operational.</column>
<column name="MaintLogID1">BRMR35028179</column>
</row>
<row>
<column name="Notes">Greased as per PM.</column>
<column name="MaintLogID1">BRMR35028180</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028181</column>
</row>
<row>
<column name="Notes">No leakage evident</column>
<column name="MaintLogID1">BRMR35028182</column>
</row>
<row>
<column name="Notes">Aux Circ pump run during condenser
shutdown</column>
<column name="MaintLogID1">BRMR35028183</column>
</row>
<row>
<column name="Notes">Fastenings checked for security. No leaks
evident. Oil tank levels satisfactory.</column>
<column name="MaintLogID1">BRMR35028184</column>
</row>
<row>
<column name="Notes">Unit flushed.</column>
<column name="MaintLogID1">BRMR35028185</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028186</column>
</row>
<row>
<column name="Notes">Flaps tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35028187</column>
</row>
<row>
<column name="Notes">Tools lubricated and inspected.</column>
<column name="MaintLogID1">BRMR35028188</column>
</row>
<row>
<column name="Notes">Sliding feet greased.</column>
<column name="MaintLogID1">BRMR35028189</column>
</row>
<row>
<column name="Notes">Sliding feet greased.</column>
<column name="MaintLogID1">BRMR35028190</column>
</row>
<row>
<column name="Notes">System checked and replenished.</column>
<column name="MaintLogID1">BRMR35028191</column>
</row>
<row>
<column name="Notes">W'shop a/c unit filters cleaned.</column>
<column name="MaintLogID1">BRMR35028192</column>
</row>
<row>
<column name="Notes">W'shop a/c unit filters cleaned.</column>
<column name="MaintLogID1">BRMR35028193</column>
</row>
<row>
<column name="Notes">System is out of action due to a passing non-
return connection for the acetylene hose.
A new set of NR conections is on order.</column>
<column name="MaintLogID1">BRMR35028194</column>
</row>
<row>
<column name="Notes">Tested externally and send DSC call to
station006010001 from station 235637000(British Merchant)
Tested satisfactory and entry made in log book.</column>
<column name="MaintLogID1">BRMR35028195</column>
</row>
<row>
<column name="Notes">All external lights switched on and left on
for several hours. Reading on insulation meter 2.% M ohm.
All lights operational.</column>
<column name="MaintLogID1">BRMR35028196</column>
</row>
<row>
<column name="Notes">Tested alarm and operating ok. Tested
telephones and auto telephone working well.
Sound powered telephone is working but reception not too good.</column>
<column name="MaintLogID1">BRMR35028197</column>
</row>
<row>
<column name="Notes">Rudder angle indicators all aligned
accurately.</column>
<column name="MaintLogID1">BRMR35028198</column>
</row>
<row>
<column name="Notes">Tested alarms and both found to be
operational.</column>
<column name="MaintLogID1">BRMR35028199</column>
</row>
<row>
<column name="Notes">Tested alarms and all found to be fully
operational.</column>
<column name="MaintLogID1">BRMR35028200</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028201</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028202</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028203</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028204</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028205</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028206</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028207</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028208</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028209</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028210</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028211</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028212</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028213</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028214</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028215</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028216</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028217</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028218</column>
</row>
<row>
<column name="Notes">Done as a part of weekly routines.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028219</column>
</row>
<row>
<column name="Notes"> tested satisfacorily</column>
<column name="MaintLogID1">BRMR35028220</column>
</row>
<row>
<column name="Notes">All tested.</column>
<column name="MaintLogID1">BRMR35028221</column>
</row>
<row>
<column name="Notes">Tested as per PM routine.
Watch Call, All call and duty call all alarmed correctly</column>
<column name="MaintLogID1">BRMR35028222</column>
</row>
<row>
<column name="Notes">Inventory checked as per Lilley and Gilley
List.
Item 10.2 Rec for Equipment used in bow mooring of tankers at SPMs out of
Date
Item 13.1 Manual on Oil Pollution Sect 2 Contingency Planning Missing
Item 17.7 Passage Planning Practice Missing
</column>
<column name="MaintLogID1">BRMR35028235</column>
</row>
<row>
<column name="Notes">All in good condition.
</column>
<column name="MaintLogID1">BRMR35028236</column>
</row>
<row>
<column name="Notes">All in good condition.
</column>
<column name="MaintLogID1">BRMR35028237</column>
</row>
<row>
<column name="Notes">Fan observed whilst running, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028238</column>
</row>
<row>
<column name="Notes">Carried out in conjunction with ETO's PM.
Belt tension adjusted. No leakage evident.</column>
<column name="MaintLogID1">BRMR35028239</column>
</row>
<row>
<column name="Notes">Carried out in conjunction with ETO's PM.
No leakage evident.</column>
<column name="MaintLogID1">BRMR35028240</column>
</row>
<row>
<column name="Notes">Carried out in conjunction with ETO's PM.
Belt tension adjusted.
No leakage evident.</column>
<column name="MaintLogID1">BRMR35028241</column>
</row>
<row>
<column name="Notes">Carried out in conjunction with ETO's PM.
Belt tension adjusted.
No leakage evident.
Evaporator blown through with compressed air.</column>
<column name="MaintLogID1">BRMR35028242</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028243</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028244</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028245</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028246</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028247</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028248</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.
Fire main pressure on bridge wing 9 bar.</column>
<column name="MaintLogID1">BRMR35028249</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028250</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028251</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028252</column>
</row>
<row>
<column name="Notes">All contacts saisfactory, connections tight,
panel clean.
motor > 100+Mohms.
</column>
<column name="MaintLogID1">BRMR35028253</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35028254</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35028255</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35028256</column>
</row>
<row>
<column name="Notes">Cleaned shaft from excess oil also cleaned
brushes.
Checked visually and found bonding cable to be in good order.</column>
<column name="MaintLogID1">BRMR35028257</column>
</row>
<row>
<column name="Notes">checked visually and checked control
operation.
all worked satisfactory.</column>
<column name="MaintLogID1">BRMR35028258</column>
</row>
<row>
<column name="Notes">Leakage from line bearing cover at bottom of
casing. On investigation, found that line bearing securing
bolts had sheared.
Cover removed, sheared bolts removed and replaced with new.</column>
<column name="MaintLogID1">BRMR35028259</column>
</row>
<row>
<column name="Notes">Inspection completed as per P.M
Found satisfactory.</column>
<column name="MaintLogID1">BRMR35028260</column>
</row>
<row>
<column name="Notes">Belts replaced on 29/08
Checked - all ok.
</column>
<column name="MaintLogID1">BRMR35028261</column>
</row>
<row>
<column name="Notes">Gear box oil level satisfactory.
Battery ok</column>
<column name="MaintLogID1">BRMR35028262</column>
</row>
<row>
<column name="Notes">Gear box oil level satisfactory.
Battery ok</column>
<column name="MaintLogID1">BRMR35028263</column>
</row>
<row>
<column name="Notes">Pump checked, no leakage observed.
Pressures within limits.
Coupling rubbers ok.
Holding down bolts secure.
</column>
<column name="MaintLogID1">BRMR35028264</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028265</column>
</row>
<row>
<column name="Notes">Monthly inspection of Liferaft carried out.
All found properly secured and in good working order.
HRU up to date.</column>
<column name="MaintLogID1">BRMR35028266</column>
</row>
<row>
<column name="Notes">Monthly inspection of Liferaft carried out.
All found properly secured and in good working order.</column>
<column name="MaintLogID1">BRMR35028267</column>
</row>
<row>
<column name="Notes">Monthly inspection of Liferaft carried out.
All found properly secured and in good working order.
HRU up to date.</column>
<column name="MaintLogID1">BRMR35028268</column>
</row>
<row>
<column name="Notes">Monthly inspection of Liferaft carried out.
All found properly secured and in good working order.
HRU up to date.</column>
<column name="MaintLogID1">BRMR35028269</column>
</row>
<row>
<column name="Notes">Monthly inspection of Liferaft carried out.
All found properly secured and in good working order.
HRU up to date.</column>
<column name="MaintLogID1">BRMR35028270</column>
</row>
<row>
<column name="Notes">Work completed as per P.M
All found satisfactory.</column>
<column name="MaintLogID1">BRMR35028271</column>
</row>
<row>
<column name="Notes">Work completed as per p.m
Found satisfactory.</column>
<column name="MaintLogID1">BRMR35028272</column>
</row>
<row>
<column name="Notes">Tank inspected internally. Crack found in
horizontal strengthening web (3 frames aft of door, inbd blkhd)
and bulkhead. Crack arrestor holed drilled at ends of cracks. Bolts,
washers and rubber seals fitted and
tightened to seal holes.
Coating in good condition, though some coating peeling off sounding pipe.
</column>
<column name="MaintLogID1">BRMR35028273</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028274</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028275</column>
</row>
<row>
<column name="Notes">Fan examined during run, no abnormal noise or
vibrations observed.
All fastenings secure, external condition satisfactory.
</column>
<column name="MaintLogID1">BRMR35028276</column>
</row>
<row>
<column name="Notes">Piston valves checked for security of
fittings. Glands tightened as reqd.</column>
<column name="MaintLogID1">BRMR35028277</column>
</row>
<row>
<column name="Notes">Piston valves checked for security of
fittings. Glands tightened as reqd.</column>
<column name="MaintLogID1">BRMR35028278</column>
</row>
<row>
<column name="Notes">oil probes checked during operation.
All satisfactory</column>
<column name="MaintLogID1">BRMR35028279</column>
</row>
<row>
<column name="Notes">Completed as per PM.
</column>
<column name="MaintLogID1">BRMR35028284</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028285</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028286</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028287</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028288</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028289</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028290</column>
</row>
<row>
<column name="Notes">Checked,regenerated and cleaned contact for
main contactor.Contacts in good condition.
Checked control box and terminal board , all connections secure.
Megger test motor >100 Mohm</column>
<column name="MaintLogID1">BRMR35028291</column>
</row>
<row>
<column name="Notes">External inspection carried out. All
fastenings secure. Fan running smoothly.</column>
<column name="MaintLogID1">BRMR35028292</column>
</row>
<row>
<column name="Notes">Fastenings secure. External inspection carried
out. No signs of rust on casing.</column>
<column name="MaintLogID1">BRMR35028293</column>
</row>
<row>
<column name="Notes">fastenings secure. External inspection carried
out. No signs of rust on casing.</column>
<column name="MaintLogID1">BRMR35028294</column>
</row>
<row>
<column name="Notes">Supply fan filters removed for cleaning, dried
and replaced.</column>
<column name="MaintLogID1">BRMR35028295</column>
</row>
<row>
<column name="Notes">Filters removed for cleaning, dried and
replaced.</column>
<column name="MaintLogID1">BRMR35028296</column>
</row>
<row>
<column name="Notes">Bot Actylene & Oxygen non return valves
opened up and cleaned, tested and found tight.
Refitted to system and system re-instated.</column>
<column name="MaintLogID1">BRMR35028297</column>
</row>
<row>
<column name="Notes">Tested and found to be fully
operational.</column>
<column name="MaintLogID1">BRMR35028298</column>
</row>
<row>
<column name="Notes">Checked control box, contactor.
Checked connections of cabel ,all secure.
Megger test motor and heaters >100Mohm.
The crane works satisfactory.</column>
<column name="MaintLogID1">BRMR35028299</column>
</row>
<row>
<column name="Notes">Checked control box, contactor.
Checked connections of cabel ,all secure.
Megger test motor and heaters >100Mohm.
The crane works satisfactory.</column>
<column name="MaintLogID1">BRMR35028300</column>
</row>
<row>
<column name="Notes">Checked control box, contactor.
Checked connections of cabel ,all secure.
Megger test motor and heaters >100Mohm.
The crane works satisfactory.</column>
<column name="MaintLogID1">BRMR35028301</column>
</row>
<row>
<column name="Notes">Checked control box, contactor.
Checked connections of cabel ,all secure.
Megger test motor and heaters >100Mohm.
The crane works satisfactory.</column>
<column name="MaintLogID1">BRMR35028302</column>
</row>
<row>
<column name="Notes">Checked control box, contactor.
Checked connections of cabel ,all secure.
Megger test motor and heaters >100Mohm.
The crane works satisfactory.</column>
<column name="MaintLogID1">BRMR35028303</column>
</row>
<row>
<column name="Notes">1- 2.60
2- 2.62
3- 2.60
4- 2.61
battery top clean and terminals in good condition.
System left on floud charger.</column>
<column name="MaintLogID1">BRMR35028304</column>
</row>
<row>
<column name="Notes">aft 13.07
fwd 13.04
checked serchlight and found working ok.
battery top clean and terminals in good condition.</column>
<column name="MaintLogID1">BRMR35028305</column>
</row>
<row>
<column name="Notes">Completed as per PM.
cells voltage:
2.05
2.05
2.05
2.05
2.06
2.06
2.05
2.05
2.05
2.05
2.05
2.07
total 24.64
</column>
<column name="MaintLogID1">BRMR35028306</column>
</row>
<row>
<column name="Notes">
Completed as per Pm.
Float charge:
1. 2.05
2. 2.05
3. 2.05
4. 2.05
5. 2.06
6. 2.06
7. 2.05
8. 2.05
9. 2.05
10. 2.05
11. 2.05
12. 2.07
total 24.64
</column>
<column name="MaintLogID1">BRMR35028307</column>
</row>
<row>
<column name="Notes">Belts replaced on 17/08
Checked- all in good condition</column>
<column name="MaintLogID1">BRMR35028308</column>
</row>
<row>
<column name="Notes">Auto start and stop functions correct.
High temperature alarm functional (105 deg-warning, 110-trip).
Cooling water high temperature alarm functional(65 deg.)
Local emergency stop operational
Safety valve tested - all ok
Air receiver low pressure alarm ok
</column>
<column name="MaintLogID1">BRMR35028309</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028310</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028311</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028312</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028313</column>
</row>
<row>
<column name="Notes">All of the bilge alarms in the Motor room and
cargo machinery room were tested as part of the
saturday routines. All alarms were found to be functioning as they
should.</column>
<column name="MaintLogID1">BRMR35028314</column>
</row>
<row>
<column name="Notes">The operation of the sound powered phone in
the cargo machinery room was tested as part of
saturday routines. The phone was found to be in good working
order.</column>
<column name="MaintLogID1">BRMR35028315</column>
</row>
<row>
<column name="Notes">The compressed air lines were checked for
water content, no water was found to be present.</column>
<column name="MaintLogID1">BRMR35028316</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028317</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028318</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028319</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028320</column>
</row>
<row>
<column name="Notes">All pneumatic dryer valves, the scrubber O/B
v/v, atomizing steam v/v and fuel shut off v/v were
all operated and all were found to be in good working order.</column>
<column name="MaintLogID1">BRMR35028321</column>
</row>
<row>
<column name="Notes">The deck gas sampling readings were recorded,
and none were noted to be rising. The IAS
readings were compared with the sample readings from the unit on A-deck,
and all seemed
to be matching up ok. The readings from the IAS gas sampling screen were
then compared
with each individual point on the sampling unit.
The reading were then recorded on the spreasheet in T drive.</column>
<column name="MaintLogID1">BRMR35028322</column>
</row>
<row>
<column name="Notes">All nitrogen fire "Snuffer"
v/v's were checked for free operation. No defects were found.</column>
<column name="MaintLogID1">BRMR35028323</column>
</row>
<row>
<column name="Notes">The following vent flaps were all operated and
lubricated. None of the below flap/dampers were
found to be stiff or diffecult to operate.
2xMotor room supply
2xCargo machinery Exhaust
2xAir lock supply
Motor room natural vent
Cargo machinry room natural vent</column>
<column name="MaintLogID1">BRMR35028324</column>
</row>
<row>
<column name="Notes">The 3 minute alarm was activated and the alarm
was audible in the cargo engineers cabin, chief
officers cabin and all public spaces.</column>
<column name="MaintLogID1">BRMR35028325</column>
</row>
<row>
<column name="Notes">The O2 meters on the Nitrogen generator was
calibrated and then returned to its,
original running condition.</column>
<column name="MaintLogID1">BRMR35028326</column>
</row>
<row>
<column name="Notes">The O2 meters on the Nitrogen generator was
calibrated and then returned to its,
original running condition.</column>
<column name="MaintLogID1">BRMR35028327</column>
</row>
<row>
<column name="Notes">Inspected as per work order. All
satisfactory.</column>
<column name="MaintLogID1">BRMR35028328</column>
</row>
<row>
<column name="Notes">Stretchers inspected as per work order. Found
complete and in good condition. All satisfactory.</column>
<column name="MaintLogID1">BRMR35028329</column>
</row>
<row>
<column name="Notes">Lightsticks found in place and in good
condition. All satisfactory.</column>
<column name="MaintLogID1">BRMR35028330</column>
</row>
<row>
<column name="Notes">Pump mechanical seal found leaking badly.
Seal cover removed, seal found seized up on shaft - cleaned and freed up.
Seal cover bolts replaced with new ones.
Pump reassembled, tested, found satisfactory.</column>
<column name="MaintLogID1">BRMR35028331</column>
</row>
<row>
<column name="Notes">Oil sample taken, clear, no particles. Not
changed this time.
LO pressures within limits set out in manuals.
Motor / comopressor units do not have couplings.
Refrigeration system checked for leaks, none found.
</column>
<column name="MaintLogID1">BRMR35028332</column>
</row>
<row>
<column name="Notes">Alarms and trips tested satisfactorily.
HO cut out at 20.5 bar
LP cut out at 0.4 bar.</column>
<column name="MaintLogID1">BRMR35028333</column>
</row>
<row>
<column name="Notes">2degC temp difference across condenser.
Corrosion plugs suitable for further use.
No signs of leakage.</column>
<column name="MaintLogID1">BRMR35028334</column>
</row>
<row>
<column name="Notes">Condensers clean and in good condition. No
internal debris. Corrosion plugs suitable for further use.
Fridge room evaporators brushed free of debris, then blown with compressed
air.
</column>
<column name="MaintLogID1">BRMR35028335</column>
</row>
<row>
<column name="Notes">Filter cleaned. Material getting thin, but
suitable for further use.</column>
<column name="MaintLogID1">BRMR35028336</column>
</row>
<row>
<column name="Notes">Supply fan filters cleaned, dried and
replaced.</column>
<column name="MaintLogID1">BRMR35028337</column>
</row>
<row>
<column name="Notes">Supply fan filters cleaned, dried and
replaced.</column>
<column name="MaintLogID1">BRMR35028338</column>
</row>
<row>
<column name="Notes">All stations inspected and in place as per C/O
spreadsheet. 12 x sterile eye patches expire this month,
local order for replacements placed.</column>
<column name="MaintLogID1">BRMR35028339</column>
</row>
<row>
<column name="Notes">Pump checked last month during D/G oil
purification.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028340</column>
</row>
<row>
<column name="Notes">All satisfactory.</column>
<column name="MaintLogID1">BRMR35028341</column>
</row>
<row>
<column name="Notes">All satisfactory.
</column>
<column name="MaintLogID1">BRMR35028342</column>
</row>
<row>
<column name="Notes">All DP extinguishers agitated.</column>
<column name="MaintLogID1">BRMR35028343</column>
</row>
<row>
<column name="Notes">As per work order.
All ok</column>
<column name="MaintLogID1">BRMR35028344</column>
</row>
<row>
<column name="Notes">As per work order.
All ok.
</column>
<column name="MaintLogID1">BRMR35028345</column>
</row>
<row>
<column name="Notes">All probes removed, cleaned and inspected -
satisfactory.
Probes o-rings greased.
Calibrating solution out of date - probes not calibrated.
New solution on order.</column>
<column name="MaintLogID1">BRMR35028346</column>
</row>
<row>
<column name="Notes">Megger test motor and heaters > 100 Mohm
Checked and cleaned contactors box.
All connections secure and contacts in good condition.
</column>
<column name="MaintLogID1">BRMR35028347</column>
</row>
<row>
<column name="Notes">Megger test motor and heaters > 100 Mohm
Checked and cleaned contactors box.
cleaned contacts for main contactor.
All connections secure and contacts in good condition.
Cleaned fan motors and motors.
All is ok.</column>
<column name="MaintLogID1">BRMR35028348</column>
</row>
<row>
<column name="Notes">Megger test motor and heaters > 100 Mohm
Checked and cleaned contactors box.
All connections secure and contacts in good condition.
</column>
<column name="MaintLogID1">BRMR35028349</column>
</row>
<row>
<column name="Notes">Megger test motor and heaters > 100 Mohm
Checked and cleaned contactors box.
All connections secure and contacts in good condition.
</column>
<column name="MaintLogID1">BRMR35028350</column>
</row>
<row>
<column name="Notes">Pump check completed as per PM.
Holding down bolts tight, coupling rubber in good condition.
No leaks spotted.
Pump back in operation.</column>
<column name="MaintLogID1">BRMR35028351</column>
</row>
<row>
<column name="Notes">Pump check completed as per PM.
Holding down bolts tight, coupling rubber in good condition.
No leaks spotted.
Pump back in operation.</column>
<column name="MaintLogID1">BRMR35028352</column>
</row>
<row>
<column name="Notes">Oil filter changed after operation of
differential alarm.</column>
<column name="MaintLogID1">BRMR35028353</column>
</row>
<row>
<column name="Notes">Analyser calibrated as per manual.</column>
<column name="MaintLogID1">BRMR35028354</column>
</row>
<row>
<column name="Notes">Filter inserts replaced as unit was showing
high differential pressure.
</column>
<column name="MaintLogID1">BRMR35028355</column>
</row>
<row>
<column name="Notes">Done as per work order.
Alarm functional
</column>
<column name="MaintLogID1">BRMR35028356</column>
</row>
<row>
<column name="Notes">Done as per work order.
Alarm functional.
</column>
<column name="MaintLogID1">BRMR35028357</column>
</row>
<row>
<column name="Notes">Cooler put into use for about one hour.
By that time no. 2 cooler inlet sea water filter cleaned and no.2 cooler
put back into use.
No.1 cooler backflushed and isolated, ready to use.
</column>
<column name="MaintLogID1">BRMR35028358</column>
</row>
<row>
<column name="Notes">No.1 cooler sw inlet filter cleaned, unit
backflushed and put back into use.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028359</column>
</row>
<row>
<column name="Notes">Done as per work order.
</column>
<column name="MaintLogID1">BRMR35028360</column>
</row>
<row>
<column name="Notes">Leaking gauge glass replaced with spare.
Removed glass overhauled and ready to use.
</column>
<column name="MaintLogID1">BRMR35028361</column>
</row>
<row>
<column name="Notes">Analyser calibrated as per manuals.</column>
<column name="MaintLogID1">BRMR35028362</column>
</row>
<row>
<column name="Notes">Flow switch replaced with spare.</column>
<column name="MaintLogID1">BRMR35028363</column>
</row>
<row>
<column name="Notes">All portable meters calibrated ok.
However, there is on occasion a slipping on the drive belt for the paper
causing a closing on the recorded information pitch,
and sometimes overlapping.
Also spurious movements from the telegraph are recording, however the
recorder is operating as designed.
Results recorded.</column>
<column name="MaintLogID1">BRMR35028391</column>
</row>
<row>
<column name="Notes">Breathaliser recalibrated and test carried
out.
All satisfactory and printer operating correctly.
Calibration gas 9/10 full</column>
<column name="MaintLogID1">BRMR35028392</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028393</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028394</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028395</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028396</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028397</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028398</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028399</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028400</column>
</row>
<row>
<column name="Notes">Sliding feet greased.</column>
<column name="MaintLogID1">BRMR35028401</column>
</row>
<row>
<column name="Notes">Sliding feet greased.</column>
<column name="MaintLogID1">BRMR35028402</column>
</row>
<row>
<column name="Notes">Completed as per PM</column>
<column name="MaintLogID1">BRMR35028403</column>
</row>
<row>
<column name="Notes">Funnel dampers operated</column>
<column name="MaintLogID1">BRMR35028404</column>
</row>
<row>
<column name="Notes">Inspected / lubricated.</column>
<column name="MaintLogID1">BRMR35028405</column>
</row>
<row>
<column name="Notes">No leakage evident</column>
<column name="MaintLogID1">BRMR35028406</column>
</row>
<row>
<column name="Notes">No leakage evident</column>
<column name="MaintLogID1">BRMR35028407</column>
</row>
<row>
<column name="Notes">Flushed as per PM.</column>
<column name="MaintLogID1">BRMR35028408</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028409</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028410</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028411</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028412</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028413</column>
</row>
<row>
<column name="Notes">Checked and found to be fully operational, 3rd
officer has put entry into gmdss log book.</column>
<column name="MaintLogID1">BRMR35028414</column>
</row>
<row>
<column name="Notes">Checked all lights and all found to be
operational. Insulation reading 2 M ohm</column>
<column name="MaintLogID1">BRMR35028415</column>
</row>
<row>
<column name="Notes">Checked alarms and found to function. Checked
telephone systems and found to function.</column>
<column name="MaintLogID1">BRMR35028416</column>
</row>
<row>
<column name="Notes">Rudder angle indicatiors all reading the
same.</column>
<column name="MaintLogID1">BRMR35028417</column>
</row>
<row>
<column name="Notes">Checked all fire sensiors on route 24 and 25
all found to be fully operational.</column>
<column name="MaintLogID1">BRMR35028418</column>
</row>
<row>
<column name="Notes">Chcecked alarms and found to be fully
operational.</column>
<column name="MaintLogID1">BRMR35028419</column>
</row>
<row>
<column name="Notes">Checked alarms and found to be fully
operational.</column>
<column name="MaintLogID1">BRMR35028420</column>
</row>
<row>
<column name="Notes">Checked all cabinets and power supplies and
found all to be working ok.</column>
<column name="MaintLogID1">BRMR35028421</column>
</row>
<row>
<column name="Notes"> fire hoses and fire hydrants tested as per
routine</column>
<column name="MaintLogID1">BRMR35028422</column>
</row>
<row>
<column name="Notes">2 bags of bio aug dosed to sewage trwatment
plant</column>
<column name="MaintLogID1">BRMR35028423</column>
</row>
<row>
<column name="Notes">stby d/gen compressors changed over. No 2 now
in use</column>
<column name="MaintLogID1">BRMR35028424</column>
</row>
<row>
<column name="Notes">stby d/gen compressors changed over. No 2 now
in use</column>
<column name="MaintLogID1">BRMR35028425</column>
</row>
<row>
<column name="Notes">GS air compressors changed over. No 2 now in
use</column>
<column name="MaintLogID1">BRMR35028426</column>
</row>
<row>
<column name="Notes">GS air compressors changed over. No 2 now in
use</column>
<column name="MaintLogID1">BRMR35028427</column>
</row>
<row>
<column name="Notes">GS air compressors changed over. No 2 now in
use</column>
<column name="MaintLogID1">BRMR35028428</column>
</row>
<row>
<column name="Notes">control air dryers changed over. outboard unit
now in use</column>
<column name="MaintLogID1">BRMR35028429</column>
</row>
<row>
<column name="Notes">control air dryers changed over. outboard unit
now in use</column>
<column name="MaintLogID1">BRMR35028430</column>
</row>
<row>
<column name="Notes">emergenct manoeuvering valve operation tested
and OK.</column>
<column name="MaintLogID1">BRMR35028431</column>
</row>
<row>
<column name="Notes">All idle machinery listed was rotated and
proved free.</column>
<column name="MaintLogID1">BRMR35028432</column>
</row>
<row>
<column name="Notes">All listed fire flaps/dampers
operated.</column>
<column name="MaintLogID1">BRMR35028433</column>
</row>
<row>
<column name="Notes">Auxy circ pump run on aux condenser for 4
hours.</column>
<column name="MaintLogID1">BRMR35028434</column>
</row>
<row>
<column name="Notes">All alarms activated satisfactorily</column>
<column name="MaintLogID1">BRMR35028435</column>
</row>
<row>
<column name="Notes">No leakage evident. Oil levels
satisfactory.</column>
<column name="MaintLogID1">BRMR35028436</column>
</row>
<row>
<column name="Notes">Patrolman and 3-minute alarm tested</column>
<column name="MaintLogID1">BRMR35028437</column>
</row>
<row>
<column name="Notes">Still awaiting spare parts. Fan still running
noisily.</column>
<column name="MaintLogID1">BRMR35028438</column>
</row>
<row>
<column name="Notes">D/G oil pressure found fluctuating and giving
surious alarms.
LO pressure sensor replaced, D/G tested, all satisfactory.</column>
<column name="MaintLogID1">BRMR35028439</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028440</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028441</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028442</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028443</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028444</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028445</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028446</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028447</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028448</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028449</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028450</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028451</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028452</column>
</row>
<row>
<column name="Notes">Rescue boat inspected as per PM, all found
satisfactory.
Loose gear in good condition and in date.
Boat in good condition.
Boat fresh water washed.</column>
<column name="MaintLogID1">BRMR35028453</column>
</row>
<row>
<column name="Notes">Alarms and trips tested satisfactorily.
mergency manoeuvring tested.</column>
<column name="MaintLogID1">BRMR35028454</column>
</row>
<row>
<column name="Notes">Tank 1 clean.
Tank 2 cleared of floc. Drain line removed and unblocked.
Tank 3 clean.
Anodes showing signs of wastage (some severe) but suitable for further use.
</column>
<column name="MaintLogID1">BRMR35028455</column>
</row>
<row>
<column name="Notes">Tank 1 clean.
Tank 2 cleared of floc. Drain line removed and unblocked.
Tank 3 clean.
Anodes showing signs of wastage (some severe) but suitable for further use.
</column>
<column name="MaintLogID1">BRMR35028456</column>
</row>
<row>
<column name="Notes">External inspection carried out. All appears
to be in good condition. No unusual noise when running.</column>
<column name="MaintLogID1">BRMR35028457</column>
</row>
<row>
<column name="Notes">Calibrated using pneumatic calibrator. Various
leaking connections tightened up.</column>
<column name="MaintLogID1">BRMR35028458</column>
</row>
<row>
<column name="Notes">EMPLOYED ETO TO CARRY OUT ALL ELECTRICAL WORK,
HE REPORTED EVERYTHING
TO BE IN GOOD WORKING ORDER.
THE FAN WAS THEN INSPECTED NO CRACKS, DAMAGE OR EROSION WAS
VISIBLE.</column>
<column name="MaintLogID1">BRMR35028459</column>
</row>
<row>
<column name="Notes">The pump was started and inspected. No leaks
or abnomalities were visible or audible. The
suction and discharge pressures were as to be expected.
The motor aws then stopped and locked in the stop position. The drive
coupling was inspected
and found to be in good condition, and the holding down bolts were checked
and secure.</column>
<column name="MaintLogID1">BRMR35028460</column>
</row>
<row>
<column name="Notes">Rescue boat engine checks completed all
satisfactory</column>
<column name="MaintLogID1">BRMR35028461</column>
</row>
<row>
<column name="Notes">All lifeboat weekly checks completed, all
satisfactory</column>
<column name="MaintLogID1">BRMR35028462</column>
</row>
<row>
<column name="Notes">All lifeboat weekly checks completed, all
satisfactory</column>
<column name="MaintLogID1">BRMR35028463</column>
</row>
<row>
<column name="Notes">All lifeboat weekly checks completed, all
satisfactory</column>
<column name="MaintLogID1">BRMR35028464</column>
</row>
<row>
<column name="Notes">All lifeboat weekly checks completed, all
satisfactory</column>
<column name="MaintLogID1">BRMR35028465</column>
</row>
<row>
<column name="Notes">hot filter changed over and cleaned</column>
<column name="MaintLogID1">BRMR35028466</column>
</row>
<row>
<column name="Notes">alarm tested and OK</column>
<column name="MaintLogID1">BRMR35028467</column>
</row>
<row>
<column name="Notes">Drain valves on no1 liquid manifold stbd and
no 2 liquid manifold port were leaking. Valves were
opened up and lapped in. The valves were then pressure tested and found to
be holding tight.</column>
<column name="MaintLogID1">BRMR35028468</column>
</row>
<row>
<column name="Notes">sample tube cleaned and alarm tested and
OK</column>
<column name="MaintLogID1">BRMR35028469</column>
</row>
<row>
<column name="Notes">Horn, connection pipes and bolts in good
condition. Slight leak on reservoir drain valve</column>
<column name="MaintLogID1">BRMR35028470</column>
</row>
<row>
<column name="Notes">Internal gears in good condition.
Horn in good condtion.
Evidence of corrosionon motor, casing and foundations. Not deep enough to
cause problems but will
keep close eye on this.</column>
<column name="MaintLogID1">BRMR35028471</column>
</row>
<row>
<column name="Notes">control air outlet pressure was found to be
dropping off so pre, after and control filters were changed.
Dessicant was also changed on this unit. Problem now identified as the
regulating valve malfunctuning.</column>
<column name="MaintLogID1">BRMR35028472</column>
</row>
<row>
<column name="Notes">all filtersOK. drier unit in good
condition.</column>
<column name="MaintLogID1">BRMR35028473</column>
</row>
<row>
<column name="Notes">flame eye cleaned. All combustion and cooling
vents cleaned.</column>
<column name="MaintLogID1">BRMR35028474</column>
</row>
<row>
<column name="Notes">Boiler alarms and trips / gas alarms and trips
carried out.
FO low press trip failed to activate first time. Press switch drained of
cold FO and test carried out again.
BOG duct fans stopped: this failed to trip the gas master v/v.
Investigation continuing and will be written
up on a seperate work order.</column>
<column name="MaintLogID1">BRMR35028475</column>
</row>
<row>
<column name="Notes">Boiler alarms and trips / gas alarms and trips
carried out.
BOG duct fans stopped: this failed to trip the gas master v/v.
Investigation continuing and will be written
up on a seperate work order.</column>
<column name="MaintLogID1">BRMR35028476</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All worked satisfactory.
All earth leakage relays tested OK.
earth straps checked - OK.</column>
<column name="MaintLogID1">BRMR35028477</column>
</row>
<row>
<column name="Notes">Visually inspected and found to be operated
satisfactory.
</column>
<column name="MaintLogID1">BRMR35028478</column>
</row>
<row>
<column name="Notes">All operational.
</column>
<column name="MaintLogID1">BRMR35028479</column>
</row>
<row>
<column name="Notes">All operational</column>
<column name="MaintLogID1">BRMR35028480</column>
</row>
<row>
<column name="Notes">Completed as per work order, no defects
reported.</column>
<column name="MaintLogID1">BRMR35028481</column>
</row>
<row>
<column name="Notes">Completed as per work order, no defects
reported.</column>
<column name="MaintLogID1">BRMR35028482</column>
</row>
<row>
<column name="Notes">Completed as per work order, no defects
reported.</column>
<column name="MaintLogID1">BRMR35028483</column>
</row>
<row>
<column name="Notes">The fan was isolated and notices posted.
The bolts were removed and motor and fan swung out to the maintenance
position. Care was taken when
swinging out the fan to give support to the door in the vertical plane so
as to prevent damage to the impeller.
Any dirt was cleaned from the impeller.
The motor and fan unit was tested using the vibration monitoring equipment,
all was found to be ok. The
results were discussed with the C/E, and it was decided that the bearings
would not need replaceing.
</column>
<column name="MaintLogID1">BRMR35028484</column>
</row>
<row>
<column name="Notes">The fan was isolated and notices were posted.
The mushroom vent was removed from the trunking.
Any dirt was cleaned from the impeller.
The motor and fan unit was tested using the vibration monitoring equipment,
all was found to be ok. The
results were discussed with the C/E, and it was decided that the bearings
would not need replaceing.
The equipment was then returned to normal condition.
</column>
<column name="MaintLogID1">BRMR35028485</column>
</row>
<row>
<column name="Notes">The fan was isolated and notices were posted.
The mushroom vent was removed from the trunking.
Any dirt was cleaned from the impeller.
The motor and fan unit was tested using the vibration monitoring equipment,
all was found to be ok. The
results were discussed with the C/E, and it was decided that the bearings
would not need replaceing.
The equipment was then returned to normal condition.
</column>
<column name="MaintLogID1">BRMR35028486</column>
</row>
<row>
<column name="Notes">Checked all fire sensiors on route 26 and
route 1.
All found to be fully operational.</column>
<column name="MaintLogID1">BRMR35028487</column>
</row>
<row>
<column name="Notes">The external condition of the fan housing and
fastenings were checked and all
found to be in good oder.
The fan was checked for any abnormal noise or vibration, also the unit was
checked using the vibration monitoring equipment. All was found to be
satisfactory.</column>
<column name="MaintLogID1">BRMR35028488</column>
</row>
<row>
<column name="Notes">The external condition of the fan housing and
fastenings were checked and all
found to be in good oder.
The fan was checked for any abnormal noise or vibration, also the unit was
checked using the vibration monitoring equipment. All was found to be
satisfactory.</column>
<column name="MaintLogID1">BRMR35028489</column>
</row>
<row>
<column name="Notes">The external condition of the fan housing and
fastenings were checked and all
found to be in good oder.
The fan was checked for any abnormal noise or vibration, also the unit was
checked using the vibration monitoring equipment. All was found to be
satisfactory.</column>
<column name="MaintLogID1">BRMR35028490</column>
</row>
<row>
<column name="Notes">
Tested alarm and operating ok. Tested telephones and auto telephone working
well.
Sound powered telephone is working but reception not too good.</column>
<column name="MaintLogID1">BRMR35028491</column>
</row>
<row>
<column name="Notes">Checked rudder angle indicator with bridge and
reading accurately.</column>
<column name="MaintLogID1">BRMR35028492</column>
</row>
<row>
<column name="Notes">Checked alarms and found to be fully
operational</column>
<column name="MaintLogID1">BRMR35028493</column>
</row>
<row>
<column name="Notes">Checked alarms and found to be fully
operational</column>
<column name="MaintLogID1">BRMR35028494</column>
</row>
<row>
<column name="Notes">One Man Bridge alarm tested as per PM.
Duty Nav on 2/O's cabin. All alarms sounded correctly.
All call and duty call tested.</column>
<column name="MaintLogID1">BRMR35028495</column>
</row>
<row>
<column name="Notes">New Manuals received and updated.
The following steps were taken to remedy the fault: With BOG fans running,
On IAS "Machinery
Fans" page-
Disabling the inputs initiated the "Both BOG Fans Stopped" alarm,
and in turn tripped the Gas Master
Valve.
Both BOG fans were then stopped from IAS. Re-enable the input signals to
MF001_LOG/MF002_LOG
and MF001 / MF002 by clicking the "Disable Input" boxes again
(this will remove the 'Tick')
'Left Click' on MF001 and 'Reset.' Repeat for MF002.
Re-start BOG fan and return both to 'Auto.'
After carrying out the above steps, the test was carried out again. This
time, upon stopping both BOG
fans the alarm was initiated and the Gas Master Valve tripped. This test
was repeated a number of
times to ensure correct operation.
It is not known why the trip system logic "stalled" for this
test, but the above steps appear to have reset the system.
</column>
<column name="MaintLogID1">BRMR35028510</column>
</row>
<row>
<column name="Notes">During testing of Master Gas Valve
trips/alarms it was noted that the Master Gas Valve failed to trip
when both BOG duct fans were stopped (The 'Both BOG Fans Stopped'
alarm also failed to sound.) Tests were repeated,
stopping fans from IAS, Swbds and local stop buttons but trip was not
initiated.
The following steps were taken to remedy the fault: With BOG fans running,
On IAS "Machinery
Fans" page-
Disabling the inputs initiated the "Both BOG Fans Stopped" alarm,
and in turn tripped the Gas Master
Valve.
Both BOG fans were then stopped from IAS. Re-enable the input signals to
MF001_LOG/MF002_LOG
and MF001 / MF002 by clicking the "Disable Input" boxes again
(this will remove the 'Tick')
'Left Click' on MF001 and 'Reset.' Repeat for MF002.
Re-start BOG fan and return both to 'Auto.'
After carrying out the above steps, the test was carried out again. This
time, upon stopping both BOG
fans the alarm was initiated and the Gas Master Valve tripped. This test
was repeated a number of
times to ensure correct operation.
It is not known why the trip system logic "stalled" for this
test, but the above steps appear to have reset the system.</column>
<column name="MaintLogID1">BRMR35028511</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028512</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028513</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028514</column>
</row>
<row>
<column name="Notes">Run on test.</column>
<column name="MaintLogID1">BRMR35028515</column>
</row>
<row>
<column name="Notes">Tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35028516</column>
</row>
<row>
<column name="Notes">Checked and all satisfactory.</column>
<column name="MaintLogID1">BRMR35028517</column>
</row>
<row>
<column name="Notes">Tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35028518</column>
</row>
<row>
<column name="Notes">Flushed.</column>
<column name="MaintLogID1">BRMR35028519</column>
</row>
<row>
<column name="Notes">Operated satisfactorily.</column>
<column name="MaintLogID1">BRMR35028520</column>
</row>
<row>
<column name="Notes">All satisfactory.</column>
<column name="MaintLogID1">BRMR35028521</column>
</row>
<row>
<column name="Notes">Greased as per PM</column>
<column name="MaintLogID1">BRMR35028522</column>
</row>
<row>
<column name="Notes">Greased as per PM</column>
<column name="MaintLogID1">BRMR35028523</column>
</row>
<row>
<column name="Notes">All satisfactory. </column>
<column name="MaintLogID1">BRMR35028524</column>
</row>
<row>
<column name="Notes">The deck gas sampling readings were recorded,
and none were noted to be rising. The IAS
readings were compared with the sample readings from the unit on A-deck,
and all seemed
to be matching up ok. The readings from the IAS gas sampling screen were
then compared
with each individual point on the sampling unit.
The reading were then recorded on the spreasheet in T drive.</column>
<column name="MaintLogID1">BRMR35028525</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028526</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028527</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028528</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028529</column>
</row>
<row>
<column name="Notes">The lub oil pumps were all started on both HD
and LD compresors. The compressors were then
turned by hand and the position the shaft stopped in was noted not to be
the position the shaft
was originally in. The temperature on the lub oil sump heaters were noted
to check they were in
operation and functioning correctly.</column>
<column name="MaintLogID1">BRMR35028530</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028531</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028532</column>
</row>
<row>
<column name="Notes">The IGV and Anti-surge v/v,s were operated and
found to be moving freely.
While the IGV v/v was being operated, the positioner drive was lubricated
with WD40.</column>
<column name="MaintLogID1">BRMR35028533</column>
</row>
<row>
<column name="Notes">All nitrogen fire "Snuffer"
v/v's were checked for free operation. No defects were found.</column>
<column name="MaintLogID1">BRMR35028534</column>
</row>
<row>
<column name="Notes">The following vent flaps wereoperated and
lubricated
</column>
<column name="MaintLogID1">BRMR35028548</column>
</row>
<row>
<column name="Notes">All alarms and trips tested. All found to be
functioning as they should. Apart from alarm
CT 154_13 which needs the plant to be running to operate.
All local alarm lights checked.
Both L.O filters are still green.
Local alarm buzzer tested.
</column>
<column name="MaintLogID1">BRMR35028549</column>
</row>
<row>
<column name="Notes">E/G on load test carried out, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028550</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028551</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028552</column>
</row>
<row>
<column name="Notes">Completed, pump stiff to turn, to be
o/hauled.</column>
<column name="MaintLogID1">BRMR35028553</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028554</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028555</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028556</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028557</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028558</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028559</column>
</row>
<row>
<column name="Notes">Completed in conjunction with on load tes, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028560</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028561</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028562</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028563</column>
</row>
<row>
<column name="Notes">No 2 main feed pump found leaking oil from aft
LO filter and thrust bearing cover.
Gaskets changed, pump tested, all satisfactory.</column>
<column name="MaintLogID1">BRMR35028564</column>
</row>
<row>
<column name="Notes">Pump sentinal valve found passing.
Valve disassembled, found rusty.
All parts cleaned, valve assembled and adjusted to 3.5 bar.</column>
<column name="MaintLogID1">BRMR35028565</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028566</column>
</row>
<row>
<column name="Notes">Filters cleaned.</column>
<column name="MaintLogID1">BRMR35028567</column>
</row>
<row>
<column name="Notes">Rescue boat engine checks completed. Engine
run on test and OK.</column>
<column name="MaintLogID1">BRMR35028568</column>
</row>
<row>
<column name="Notes">Life boat weekly checks completed. Engine
started on both batteries and OK. Fuel level good.</column>
<column name="MaintLogID1">BRMR35028569</column>
</row>
<row>
<column name="Notes">Life boat weekly checks completed. Engine
started on both batteries and OK. Fuel level good.</column>
<column name="MaintLogID1">BRMR35028570</column>
</row>
<row>
<column name="Notes">Weekly life boat checks completed. Air
pressure good, all hatch seals good, sea inlet valve for sprinkler
free, sprinkler pump V-belts in good condition.</column>
<column name="MaintLogID1">BRMR35028571</column>
</row>
<row>
<column name="Notes">Weekly life boat checks completed. Air
pressure good, all hatch seals good, sea inlet valve for sprinkler
free, sprinkler pump V-belts in good condition.</column>
<column name="MaintLogID1">BRMR35028572</column>
</row>
<row>
<column name="Notes">Air dryers changed over, No 2 (inboard) now in
use.</column>
<column name="MaintLogID1">BRMR35028573</column>
</row>
<row>
<column name="Notes">Air dryers changed over, No 2 (inboard) now in
use.</column>
<column name="MaintLogID1">BRMR35028574</column>
</row>
<row>
<column name="Notes">air compressors changed over No 3, inboard now
in use.</column>
<column name="MaintLogID1">BRMR35028575</column>
</row>
<row>
<column name="Notes">air compressors changed over No 3, inboard now
in use.</column>
<column name="MaintLogID1">BRMR35028576</column>
</row>
<row>
<column name="Notes">air compressors changed over No 3, inboard now
in use.</column>
<column name="MaintLogID1">BRMR35028577</column>
</row>
<row>
<column name="Notes">Stby gen air compressors changed over, No 1
now in use.</column>
<column name="MaintLogID1">BRMR35028578</column>
</row>
<row>
<column name="Notes">Stby gen air compressors changed over, No 1
now in use.</column>
<column name="MaintLogID1">BRMR35028579</column>
</row>
<row>
<column name="Notes">2 bags of bio augmentation added to sewage
treatment plant.</column>
<column name="MaintLogID1">BRMR35028580</column>
</row>
<row>
<column name="Notes">All portable meters calibrated ok.
</column>
<column name="MaintLogID1">BRMR35028631</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System operating satisfactory.</column>
<column name="MaintLogID1">BRMR35028632</column>
</row>
<row>
<column name="Notes">All operating satisfactory.
Tested weekly& allb tests carried out satisfactory.</column>
<column name="MaintLogID1">BRMR35028633</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System operating satisfactory.</column>
<column name="MaintLogID1">BRMR35028634</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System operating satisfactory.</column>
<column name="MaintLogID1">BRMR35028635</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System operating satisfactory.
New displays on order.</column>
<column name="MaintLogID1">BRMR35028636</column>
</row>
<row>
<column name="Notes">All fully functional.Intermittent fault loop
4.
Contuning to persue conclusion on fault.</column>
<column name="MaintLogID1">BRMR35028637</column>
</row>
<row>
<column name="Notes">Checked rudder bonding cable.
Checked and cleaned shaft earthing device slip ring and brush gear.
</column>
<column name="MaintLogID1">BRMR35028638</column>
</row>
<row>
<column name="Notes">All alarms and trips tested as per work order,
all foun operational at design settings.
Pump tested, back in stand by.</column>
<column name="MaintLogID1">BRMR35028639</column>
</row>
<row>
<column name="Notes">Monthly inpection of pyrotechnics carrid out.
All found up to date and stowed properly.</column>
<column name="MaintLogID1">BRMR35028640</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028641</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028642</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028643</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028644</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028645</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028646</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028647</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028648</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028649</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028650</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028651</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028652</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028653</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028654</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028655</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028656</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028657</column>
</row>
<row>
<column name="Notes">Completed as per W.O.</column>
<column name="MaintLogID1">BRMR35028658</column>
</row>
<row>
<column name="Notes">All in good working order.</column>
<column name="MaintLogID1">BRMR35028659</column>
</row>
<row>
<column name="Notes">Control air lines to the air inlet solenoid
and pressure regulator have been cleaned out due to moisture / dust build
up.
The pressure control valve open soleniod was completly blocked up and
caused the valve to remain in its fail safe position.
All was made good and the valve tested on completion.
The actuator for the shut off valve was about 30% full of water. The
actuator was removed and overhauled. All was tested on completion.</column>
<column name="MaintLogID1">BRMR35028660</column>
</row>
<row>
<column name="Notes">Due to the problems with No1 unit ( see W.O
MER/07/05467 ). The control air lines to the air
inlet and pressure regulator where all blown through and proved to be
clear.</column>
<column name="MaintLogID1">BRMR35028661</column>
</row>
<row>
<column name="Notes">All test points tested, all where in good
working condition.
The only points not tested where the cofferdams and the duct keel.
Both the 50%LEL, and the 100%Volume analiser's where
calibrated.</column>
<column name="MaintLogID1">BRMR35028662</column>
</row>
<row>
<column name="Notes">Checked all fire heads and manual call points
in routes 2 and 3 all found to be operational.
Intermittent fault in zone 4 with the UV fire head in incinerator tank
room. This under observation.</column>
<column name="MaintLogID1">BRMR35028663</column>
</row>
<row>
<column name="Notes">hecked operaion of alarms and sound powered
telephones and all working.</column>
<column name="MaintLogID1">BRMR35028664</column>
</row>
<row>
<column name="Notes">Indicator units all operational and
accurate.</column>
<column name="MaintLogID1">BRMR35028665</column>
</row>
<row>
<column name="Notes">Alarms fully functional</column>
<column name="MaintLogID1">BRMR35028666</column>
</row>
<row>
<column name="Notes">Alarms found to be fully functional </column>
<column name="MaintLogID1">BRMR35028667</column>
</row>
<row>
<column name="Notes">All found to be full fuctional except one
above entrace upper deck port side. On order new charger,
ballast unit. Insulation readings up to 2 mega ohm. </column>
<column name="MaintLogID1">BRMR35028668</column>
</row>
<row>
<column name="Notes">One man bridge alarm test carried out as per
PM Routine.
All satisfactory.</column>
<column name="MaintLogID1">BRMR35028669</column>
</row>
<row>
<column name="Notes">All bilges dry and all alarms tested and
operational.
</column>
<column name="MaintLogID1">BRMR35028670</column>
</row>
<row>
<column name="Notes">All bilges dry and all alarms tested
operational.</column>
<column name="MaintLogID1">BRMR35028671</column>
</row>
<row>
<column name="Notes">Completed as per work order and no defects
observed.</column>
<column name="MaintLogID1">BRMR35028672</column>
</row>
<row>
<column name="Notes">Completed as per work order and no defects
observed.</column>
<column name="MaintLogID1">BRMR35028673</column>
</row>
<row>
<column name="Notes">Completed as per work order and no defects
observed.</column>
<column name="MaintLogID1">BRMR35028674</column>
</row>
<row>
<column name="Notes">This PM not carried out. Following lift
accident some time ago, still only doing 6 monthly inspections.</column>
<column name="MaintLogID1">BRMR35028675</column>
</row>
<row>
<column name="Notes">Rescue boat weekly checks completed. all
working well.</column>
<column name="MaintLogID1">BRMR35028676</column>
</row>
<row>
<column name="Notes">Fuel and oil levels good, engine tested on
both batteries and started no problems.</column>
<column name="MaintLogID1">BRMR35028677</column>
</row>
<row>
<column name="Notes">Fuel and oil levels good, engine tested on
both batteries and started no problems.</column>
<column name="MaintLogID1">BRMR35028678</column>
</row>
<row>
<column name="Notes">Control air driers changed over, No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35028679</column>
</row>
<row>
<column name="Notes">Control air driers changed over, No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35028680</column>
</row>
<row>
<column name="Notes">GS air compressors changed over, No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35028681</column>
</row>
<row>
<column name="Notes">GS air compressors changed over, No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35028682</column>
</row>
<row>
<column name="Notes">GS air compressors changed over, No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35028683</column>
</row>
<row>
<column name="Notes">Stby D/gen air start compressors changed over,
No 2 unit now in use.</column>
<column name="MaintLogID1">BRMR35028684</column>
</row>
<row>
<column name="Notes">Stby D/gen air start compressors changed over,
No 2 unit now in use.</column>
<column name="MaintLogID1">BRMR35028685</column>
</row>
<row>
<column name="Notes">2 bas of bio augmentation dosed to sewage
treatment plant.</column>
<column name="MaintLogID1">BRMR35028686</column>
</row>
<row>
<column name="Notes">Boiler hot HFO filters cleaned as
required.</column>
<column name="MaintLogID1">BRMR35028687</column>
</row>
<row>
<column name="Notes">Alarm tested and OK.</column>
<column name="MaintLogID1">BRMR35028688</column>
</row>
<row>
<column name="Notes">Lifeboat batteries checked and OK, all hatch
gaskets in good condition, Bottle pressures both 185bar.</column>
<column name="MaintLogID1">BRMR35028689</column>
</row>
<row>
<column name="Notes">Lifeboat batteries checked and OK, all hatch
gaskets in good condition, Bottle pressures both 190bar.</column>
<column name="MaintLogID1">BRMR35028690</column>
</row>
<row>
<column name="Notes">Hydraulics unit run on test and filter
indicator showing filter in good condition.
Oil sample drawn and in good condition.
Oil gravity tank level at lower green line.</column>
<column name="MaintLogID1">BRMR35028691</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028692</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028693</column>
</row>
<row>
<column name="Notes">No leakage evident.</column>
<column name="MaintLogID1">BRMR35028694</column>
</row>
<row>
<column name="Notes">Run on test for 4 hours.</column>
<column name="MaintLogID1">BRMR35028695</column>
</row>
<row>
<column name="Notes">All tested satisfactorily.</column>
<column name="MaintLogID1">BRMR35028696</column>
</row>
<row>
<column name="Notes">Inspected as per PM</column>
<column name="MaintLogID1">BRMR35028697</column>
</row>
<row>
<column name="Notes">Tested satisfactorily (alarms activate after
15mins)</column>
<column name="MaintLogID1">BRMR35028698</column>
</row>
<row>
<column name="Notes">Flushed</column>
<column name="MaintLogID1">BRMR35028699</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35028700</column>
</row>
<row>
<column name="Notes">Sliding feet lubricated</column>
<column name="MaintLogID1">BRMR35028701</column>
</row>
<row>
<column name="Notes">Sliding feet lubricated</column>
<column name="MaintLogID1">BRMR35028702</column>
</row>
<row>
<column name="Notes">No defects noted to 2E</column>
<column name="MaintLogID1">BRMR35028703</column>
</row>
<row>
<column name="Notes">Satisfactory</column>
<column name="MaintLogID1">BRMR35028704</column>
</row>
<row>
<column name="Notes">This unit is currently under maintenance.
Trips not tested this time.</column>
<column name="MaintLogID1">BRMR35028705</column>
</row>
<row>
<column name="Notes">Cut outs operating satisfactorily.</column>
<column name="MaintLogID1">BRMR35028706</column>
</row>
<row>
<column name="Notes">Overhauled. Load tested to 0.47 tonne.
Gangway swung out atfer the load test.</column>
<column name="MaintLogID1">BRMR35028707</column>
</row>
<row>
<column name="Notes">Drive coulping cover renewed with spare
unit.</column>
<column name="MaintLogID1">BRMR35028708</column>
</row>
<row>
<column name="Notes">Completed as per work order.</column>
<column name="MaintLogID1">BRMR35028709</column>
</row>
<row>
<column name="Notes">Fan opened up due to excessive noise. fault
was found to be corrosion in behind the blade wear ring, which forced
the ring onto the blades.
Wear ring removed. Fan running smoothly again.</column>
<column name="MaintLogID1">BRMR35028710</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028711</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028712</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028713</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028714</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028715</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028716</column>
</row>
<row>
<column name="Notes">Completed as per weekly routine, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028717</column>
</row>
<row>
<column name="Notes">Fan removed, wear ring removed, and the casing
was descaled then re painted.
New bearings fitted to motor.</column>
<column name="MaintLogID1">BRMR35028718</column>
</row>
<row>
<column name="Notes">Filters cleaned and replaced.</column>
<column name="MaintLogID1">BRMR35028719</column>
</row>
<row>
<column name="Notes">Filters cleaned and replaced.</column>
<column name="MaintLogID1">BRMR35028720</column>
</row>
<row>
<column name="Notes">Port boiler O2 analyser operating unreliably.
Alarms E14 / E17 indicating from time to time. Manual
indicates this is a "Broken Lead Wire IP-". Voltages across
terminal 3 and 4 taken when unit in use (as
per instructions) and voltages found to be out of reqd range.
New probe fitted and allowed to warm up before returning unit to service.
Unit calibrated and operating
correctly. </column>
<column name="MaintLogID1">BRMR35028721</column>
</row>
<row>
<column name="Notes">Filters cleaned
</column>
<column name="MaintLogID1">BRMR35028722</column>
</row>
<row>
<column name="Notes">Filters cleaned</column>
<column name="MaintLogID1">BRMR35028723</column>
</row>
<row>
<column name="Notes">Calibrated satisfactorily</column>
<column name="MaintLogID1">BRMR35028724</column>
</row>
<row>
<column name="Notes">Calibrated satisfactorily</column>
<column name="MaintLogID1">BRMR35028725</column>
</row>
<row>
<column name="Notes">AHU sprayed with hypochlorite
solution.</column>
<column name="MaintLogID1">BRMR35028726</column>
</row>
<row>
<column name="Notes">Removed temporary power supply and installed
new power supply unit. This found to be working
satisfactory and system now operating normally. </column>
<column name="MaintLogID1">BRMR35028727</column>
</row>
<row>
<column name="Notes">Oil drained and replaced with new one.
Both filters indicating high differential pressure - replaced with spare
ones.
Aft filter found full of very fine metal filings - probably aftermath of
last thrust bearing failure.
Filter housings cleaned.
Pump run on test - satisfactory.
Pump back on line.</column>
<column name="MaintLogID1">BRMR35028728</column>
</row>
<row>
<column name="Notes">30/09/07
station to 006010001
station from 235637000
12577kHz
All ok.</column>
<column name="MaintLogID1">BRMR35028729</column>
</row>
<row>
<column name="Notes">"S" Band radar checked in operation
and the gearbox was found to be slightly noisy, Kelvin Hughes contacted in
order to obtain
information, however replied that the unit is not serviceable.
Therefore operation to be monitored in case of deterioration.
Dear Sir:
Thank you for your e mail regarding the S Band gearbox, in answer to your
questions:
As such the drawings will not be help as the gears are not available as
individual items, in addition to which to remove the top plate requires
dis-assembly of the rotating joint and array.
Best Regards
________________________________
Dear Technical,
Many thanks
Sandra
Sandra Leonard
Kelvin Hughes Limited
Customer Service Department
Tel: +44 20 8502 6887 extn 4208
Fax: +44 20 8559 8526
-----Original Message-----
From: British Merchant - Chief Engineer [mailto:ceng.merchant@bpfleet.com]
Sent: 01 October 2007 00:46
To: Leonard, Sandra (SHNM)
Subject: British Merchant - S Band Radar Gearbox
G'Day,
UNIT DETAILS:
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
</column>
<column name="MaintLogID1">BRMR35028730</column>
</row>
<row>
<column name="Notes">Accomodation ladder inspected and found
satisfactory. All parts greased
As noted in the air motor history:-
Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.</column>
<column name="MaintLogID1">BRMR35028731</column>
</row>
<row>
<column name="Notes">Accomodation ladder inspected and found
satisfactory. All parts greased
As noted in the air motor history:-
Air motors operated on test. ok.
lubricators working satis. resevoirs topped up.</column>
<column name="MaintLogID1">BRMR35028732</column>
</row>
<row>
<column name="Notes">Nets checked , all OK. Stored in the Trunk
Deck.</column>
<column name="MaintLogID1">BRMR35028733</column>
</row>
<row>
<column name="Notes">Wire Strops, Chain Blocks, Webbing Strops and
Wooden Blocks all checked as per lists in Lifting Gear Register.
Missing Green Tags replaced where necessary.</column>
<column name="MaintLogID1">BRMR35028734</column>
</row>
<row>
<column name="Notes">Crane greased and tested as per work order.
All limits opertional and correct.
</column>
<column name="MaintLogID1">BRMR35028735</column>
</row>
<row>
<column name="Notes">Crane greased and tested as per work order,
all limits operational and correct.
Cargo runner winch motor shaft seal appears to have a slight leak. Oil
topped up and to be monitored during future use.</column>
<column name="MaintLogID1">BRMR35028736</column>
</row>
<row>
<column name="Notes">Crane operated satisfactorily. Limits tested
ok.
Crane greased as per PM</column>
<column name="MaintLogID1">BRMR35028737</column>
</row>
<row>
<column name="Notes">Crane operated satisfactorily. Limits tested
ok.
Crane greased as per PM</column>
<column name="MaintLogID1">BRMR35028738</column>
</row>
<row>
<column name="Notes">Crane operated satisfactorily. Limits tested
ok.
Crane greased as per PM</column>
<column name="MaintLogID1">BRMR35028739</column>
</row>
<row>
<column name="Notes">Damper for pump room nat vent fully
overhauled. Damper removed and shaft cleaned. Damper scaled and painted,
cowling scaled and painted and mushroom cover scaled and painted.
All accumulator bladers where checked. An average pressure was 8.5, all
have been topped up to 8.8Mpa.
None of the blader pressures where excessive low.
The lag machines temperature probe was put into the hot box, set at 80
degrees C.
The lag machine cut out.
Stopped draining air receiver and reset machines.
One of the air receivers was drained to check the auto cut in and out
pressure
With #1 on lead
#1 compressor cut in at 25 bar
#2 compressor cut in at 23 bar
#1 compressor cut out at 30 bar
#2 compressor cut out at 30 bar
Many thanks your assistance, fuse was found blown, changed and now all
satisfactory.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
Dear John
Best Regards
Best regards,
Marianne Pedersen
G'Day Marianne,
-----
From: KM Support
Date: Tue, 9 Oct 2007 13:12 +0000 Msg: AMOS-99367470
Subject: Re: British Merchant - Konsberg IAS
To: British Merchant - Chief Engineer
Good day,
After replacing the switch, please let me know if the problem was solved.
Best regards,
Marianne Pedersen
G'Day,
The vessel has experienced a fault on the IAS Kongsberg system, indication
is
"ERROR Network A"
Upon investigation it was noted that the Fast ethernet unit in station NDU
A2
has a RED LED fault indication.
Please advise if the Fast Ethernet switching unit 8118 can be powered down
without causing any distribution to the IAS system?
FYR: The vessel has 2 off spare Ethernet switching units onboard, Type AT-
8024-
50, please advise if the 2 off spare units are a direct replacement for the
original unit, and therefore can be fitted should the fault not be cleared
by
powering down.
</column>
<column name="MaintLogID1">BRMR35028942</column>
</row>
<row>
<column name="Notes">All lifebuoys checked and found in good
condition. New lifebuoy lights arrived in Trinidad and fitted, Ep date July
2012.</column>
<column name="MaintLogID1">BRMR35028943</column>
</row>
<row>
<column name="Notes">Para Guard and Robinson stretchers checked as
per PM. All found in reasonable condition, In the correct location and with
all parts present.</column>
<column name="MaintLogID1">BRMR35028944</column>
</row>
<row>
<column name="Notes">Both International Shore Connections checked
and found in good condition and all parts present.</column>
<column name="MaintLogID1">BRMR35028945</column>
</row>
<row>
<column name="Notes">All gauges and thermometers in good working
order.</column>
<column name="MaintLogID1">BRMR35028946</column>
</row>
<row>
<column name="Notes">All sets inspected and in good condition. All
sets at the correct pressure.</column>
<column name="MaintLogID1">BRMR35028947</column>
</row>
<row>
<column name="Notes">New section of pipework fabricated (1 inch
bore)and fitted at B-deck level o ER to enable correct
throughput of water for operating HP washer.</column>
<column name="MaintLogID1">BRMR35028948</column>
</row>
<row>
<column name="Notes">Filters checked recently, and unit not run
since, so not cleaned this time.</column>
<column name="MaintLogID1">BRMR35028949</column>
</row>
<row>
<column name="Notes">V belts tight and sprinkler pump in good
condition. greased and OK. </column>
<column name="MaintLogID1">BRMR35028950</column>
</row>
<row>
<column name="Notes">V belts tight and sprinkler pump in good
condition. greased and OK.</column>
<column name="MaintLogID1">BRMR35028951</column>
</row>
<row>
<column name="Notes">Tested on a 2 weekly basis to save draining
too much water from the system.</column>
<column name="MaintLogID1">BRMR35028952</column>
</row>
<row>
<column name="Notes">all sections emptied, cleaned and refilled. 2
bags bio aug dosed direct to aeration chamber. Unit put
back on line. All is now Good.</column>
<column name="MaintLogID1">BRMR35028953</column>
</row>
<row>
<column name="Notes">Oil flushed and changed as per P.M.</column>
<column name="MaintLogID1">BRMR35028954</column>
</row>
<row>
<column name="Notes">Defective chiller flow switch replaced.
See work order MER/07/05808 for electrical problems associated with this
compressor.</column>
<column name="MaintLogID1">BRMR35028955</column>
</row>
<row>
<column name="Notes">Discharged batteries for 3 hours and took
readings of each cell.
1. 2.07
2. 2.07
3. 2.06
4. 2.06
5. 2.06
6. 2.06
7. 2.06
8. 2.06
9. 2.06
10. 2,06
11. 2.07
12. 2.06
discharge current waa a steady 0.04 amps and voltage was 24.9 volts.
All cells in a good condition and entered into deck log book. </column>
<column name="MaintLogID1">BRMR35028956</column>
</row>
<row>
<column name="Notes">Switched power off for 3 hours and took
readings of each cell.
1. 2.04
2. 2.03
3. 2.04
4. 2.03
5. 2.04
6. 2.04
7. 2.04
8. 2.03
9. 2.03
10. 2.03
11. 2.04
12.2.03
voltage 23.9volts at 24.9 amps drawn. All cells in a good
condition.</column>
<column name="MaintLogID1">BRMR35028957</column>
</row>
<row>
<column name="Notes">This probe was cleaned on the 4th October the
probe was changed for a new one.
Changed by the 2/e. </column>
<column name="MaintLogID1">BRMR35028958</column>
</row>
<row>
<column name="Notes">Tests carried out satisfactorily prior to
arrival in US waters.</column>
<column name="MaintLogID1">BRMR35028959</column>
</row>
<row>
<column name="Notes">All grease points were greased. The condition
of the rollers were checked and
looked in good condition.</column>
<column name="MaintLogID1">BRMR35028960</column>
</row>
<row>
<column name="Notes">All grease points were greased. The condition
of the rollers were checked and
looked in good condition.</column>
<column name="MaintLogID1">BRMR35028961</column>
</row>
<row>
<column name="Notes">The grease point was lubricated. The oil level
in the gear box was checked and found
to be at the correct level.</column>
<column name="MaintLogID1">BRMR35028962</column>
</row>
<row>
<column name="Notes">The grease point was lubricated. The oil level
in the gear box was checked and found
to be at the correct level.</column>
<column name="MaintLogID1">BRMR35028963</column>
</row>
<row>
<column name="Notes">The HFO transfer filter was isolated by the
4th eng. The rest of the work was carried
out by the oilers. They reported back that the filter was cleaned and
returned. The
pump was then de-isolated and returned to stand-by condition.</column>
<column name="MaintLogID1">BRMR35028964</column>
</row>
<row>
<column name="Notes">1- 2.60
2- 2.63
3- 2.60
4- 2.60
battery top clean, terminals in good condition.</column>
<column name="MaintLogID1">BRMR35028965</column>
</row>
<row>
<column name="Notes"> aft 13.1
fwd 12.9
Many thanks for the info you have supplied to date, it has been very much
appreciated, however a little disappointed with the
reply from ABB support line, especially considering the length of time the
ballast pump has actually been out of service.
Both the REM units fitted to No.3 ballast pumps and also the onboard spare
"un- programmed" unit have been opened during
previous fault finding, therefore the seals were already broken and as per
ABB support, the guarantee would already be void.
Therefore went ahead and fitted the relay card from the spare onboard
"un- programmed" unit.
No.3 ballast pump was then tested in service and all was found to be
satisfactory.
Would therefore suggest that the un-programmed REM unit, which is now
fitted with the defective relay card, be returned to ABB
for repair and configuration for ballast pump use, therefore please advise
forwarding details and repair / re-programming cost
estimations.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: graham.black@gb.abb.com
Date: Thu, 11 Oct 2007 10:24 +0000 Msg: AMOS-99598552
Subject: Re: British Merchant - No.3 Ballast Pump Rem Unit.
To: British Merchant - Chief Engineer
Cc: Parker, Mike \(BP Shipping\)
Hi John,
I have a reply from our Support Line, please note comments.
Graham K Black
Service Co-ordinator
ABB Ltd,
21-25 Commerce Street,
ABERDEEN.
Phone: +44 (0)1224 592 123
Telefax: +44 (0)1224 592 690
email: graham.black@gb.abb.com
Web: www.abb.com
"British Merchant - Chief Engineer"
<ceng.merchant@bpfleet.com>
09/10/2007 00:02
To
Graham K Black/GBINS/ABB@ABB
cc
"Parker, Mike \(BP Shipping\)" <Mike.Parker@bp.com>
Subject
Re: British Merchant - No.3 Ballast Pump Rem Unit.
Hi Graham,
The Rem unit presently fitted, S/N - ER114283, is the one giving the
problem.
Planned next step is to replace the suspect output relay utilizing the
relay
from the un-programmed Rem unit.
If this does not rectify the fault, then will then have to land one of the
units
back to you for repair and reprogramming as required.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: graham.black@gb.abb.com
Date: Thu, 4 Oct 2007 16:02 +0000 Msg: AMOS-98847431
Subject: Re: British Merchant - No.3 Ballast Pump Rem Unit.
To: British Merchant - Chief Engineer
Cc: Parker, Mike \(BP Shipping\)
Hi John,
The board we are speaking about it is contained within REM545 Protection
Relay.
Other than BPS Drawings and Drgs contained within REM545 Manual there are
no additional internal drawings available, you
pretty much have them all.
As I am sure you can appreciate, without being on site and as we have only
Graham K Black
Service Co-ordinator
ABB Ltd,
21-25 Commerce Street,
ABERDEEN.
Phone: +44 (0)1224 592 123
Telefax: +44 (0)1224 592 690
email: graham.black@gb.abb.com
Web: www.abb.com
To
Graham K Black/GBINS/ABB@ABB
cc
"Parker, Mike \(BP Shipping\)" <Mike.Parker@bp.com>
Subject
Re: British Merchant - No.3 Ballast Pump Rem Unit.
G'Day Graham,
Many thanks for the info, please advise if the output relay is actually
fitted
inside the REM unit, also please could you forward a circuit diagram of
the REM
unit internal connections.
Understand to isolate the REM unit, we require to switch off the 2 power
supply
switches at the back of the unit and also disconnection of the CT on the
back
terminal strip, please advise if this is correct. As an alternative to
powering
down the complete switchboard.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: graham.black@gb.abb.com
Date: Wed, 3 Oct 2007 09:01 +0000 Msg: AMOS-98674177
Subject: Fw: British Merchant - No.3 Ballast Pump Rem Unit.
To: British Merchant - Chief Engineer
Cc: Parker, Mike \(BP Shipping\)
Hi John,
Please find attached additional information from ABB Supportline.
I await you response to previous information sent.
Graham K Black
Service Co-ordinator
ABB Ltd,
21-25 Commerce Street,
ABERDEEN.
Phone: +44 (0)1224 592 123
Telefax: +44 (0)1224 592 690
email: graham.black@gb.abb.com
Web: www.abb.com
----- Forwarded by Graham K Black/GBINS/ABB on 03/10/2007 09:56 -----
Graham K Black/GBINS/ABB
01/10/2007 17:36
To
"British Merchant - Chief Engineer"
<ceng.merchant@bpfleet.com>
cc
"Parker, Mike (BP Shipping)" <Mike.Parker@bp.com>
Subject
British Merchant - No.3 Ballast Pump Rem Unit.
Hi John,
I have asked one of our Engineers Stephen Brady to have a look at this
issue.
Our provisional response and hence guidance only is detailed below:-
In summary we could quote you for a replacement 7.2 I/O board however
there is no guarantee this is the problem, the only way we can be sure is
if you return the relay to us (I know this is not an option). Can you
confirm if No.3 Ballast Pump has become 'non operational.' If you
have
linked out as described, then there should be no problem with the
operation unless there is another possibly unrelated fault.
Graham K Black
Service Co-ordinator
ABB Ltd,
21-25 Commerce Street,
ABERDEEN.
Phone: +44 (0)1224 592 123
Telefax: +44 (0)1224 592 690
email: graham.black@gb.abb.com
Web: www.abb.com
Graham K Black/GBINS/ABB
01/10/2007 12:02
To
"British Merchant - Chief Engineer"
<ceng.merchant@bpfleet.com>
cc
"Parker, Mike (BP Shipping)" <Mike.Parker@bp.com>
Subject
British Merchant - No.3 Ballast Pump Rem Unit.
Hi John,
I have passed your enquiry to ABB Aftersales in Finland, I would expect a
response within the next 1 to 2 days.
I would suggest we wait until reply from Aftersales Relay, the option
exists to mobilise an Engineer but we need
to make sure he is the correct person for this job.
My apology's for not getting back sooner, I had not picked up that
No.3
Ballast Pump was non operational.
Graham K Black
Service Co-ordinator
ABB Ltd,
21-25 Commerce Street,
ABERDEEN.
Phone: +44 (0)1224 592 123
Telefax: +44 (0)1224 592 690
email: graham.black@gb.abb.com
Web: www.abb.com
To
Graham K Black/GBINS/ABB@ABB
cc
"Parker, Mike (BP Shipping)" <Mike.Parker@bp.com>
Subject
British Merchant - No.3 Ballast Pump Rem Unit.
G'Day Graham,
This problem has still not been resolved, and therefore No.3 ballast pump
has
been non-operation for some considerable time, which obviously is not
acceptable.
Please advise on an urgent basis how we can resolve this ongoing issue.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
Hi Sunil,
I have your original e-mail, the contents are being reviewed technically.
There are many questions to be asked/answered hence perhaps the best bet
is if you speak to a Ref/Rem Engineer next week or someone appropriate.
Regards
Contracts Co-ordinator
Graham K Black
11/05/2007 16:07
Internal
Repeat send......
Today we fitted the new REM unit for No.3 Ballast Pump. When everything
was re-connected we found
that we have an alarm on the ships IAS saying 'No.3 B.P START
READY',
which we could not
acknowledge. This signal was causing a start interlock for Ballast pump on
We have left the link between 3 & 4 and tested all the interlocks,
including the ABB breaker
interlocks, and they are all work fine. But we are still left with this
link. Could this be due to
software or the internal relay on the X7.2 card being defective?
Please advise if there is something we have missed. The link works fine
for now, but may cause
confusion should this unit have to be replaced in the future.
Best regards
Sunil Mohotti
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
</column>
<column name="MaintLogID1">BRMR35028985</column>
</row>
<row>
<column name="Notes">Pump run up to running conditions all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028986</column>
</row>
<row>
<column name="Notes">Pump run upto running condition all
satisfactory.</column>
<column name="MaintLogID1">BRMR35028987</column>
</row>
<row>
<column name="Notes">IBS/IS spaces to be measured externally using
the portable analyser. Independent samples to be taken at the liquid and
gas domes at the following points,
for LEL & O2. This is to ensure that there is not a problem in the N2
supply and that the gas sampling unit is measuring correctly.
# 4
Liquid Dome IBS CN 430 - 0%LEL - 1.3%O2
# 1 # 2 # 3
Liquid Dome IBS CN 330 - 0%LEL - 1.4%O2
# 2
Liquid Dome IBS CN 230 - 0%LEL - 1.2%O2
# 1
Liquid Dome IBS CN 130 - 0%LEL - 1.4%O2
</column>
<column name="MaintLogID1">BRMR35029014</column>
</row>
<row>
<column name="Notes">Fixed pipework appears to be in good
condition.
Stainless steel bends in good condition, but some rust spots on crimped
connections of hoses (these
are due for replacement in refit (as per 48 monthly WO))
New flashback arrestors fitted to shank.
Shank oxygen & acetylene valves renewed on burning torch.
</column>
<column name="MaintLogID1">BRMR35029015</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029016</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029017</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029018</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029019</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029020</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029021</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029022</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029023</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029024</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029025</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029026</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029027</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029028</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029029</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029030</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029031</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good
order.</column>
<column name="MaintLogID1">BRMR35029032</column>
</row>
<row>
<column name="Notes">Completed as per W.O. All in good order. Fans
changed over. No.1's are now in use.</column>
<column name="MaintLogID1">BRMR35029033</column>
</row>
<row>
<column name="Notes">One man bridge alarm tested as per PM routine.
All satisfactory,</column>
<column name="MaintLogID1">BRMR35029034</column>
</row>
<row>
<column name="Notes">All idle machinery listed was rotated and
proved free.</column>
<column name="MaintLogID1">BRMR35029035</column>
</row>
<row>
<column name="Notes">This PM is completed by the Engine room crew
as part of the saterday routines.
BR x4/e</column>
<column name="MaintLogID1">BRMR35029036</column>
</row>
<row>
<column name="Notes">The ppm monitor was tested, as per the
instructions on the PM. There was no need for
recalibrationof the unit. The desiccator does not need replacing as
yet.</column>
<column name="MaintLogID1">BRMR35029037</column>
</row>
<row>
<column name="Notes">All operating satisfactorily.</column>
<column name="MaintLogID1">BRMR35029038</column>
</row>
<row>
<column name="Notes">All operating satisfactorily.</column>
<column name="MaintLogID1">BRMR35029039</column>
</row>
<row>
<column name="Notes">Sent dsc to cape town 006010001 from ship
23563700 on 12 mhz and test messge acknoledged ok.</column>
<column name="MaintLogID1">BRMR35029040</column>
</row>
<row>
<column name="Notes">All lights on for 4 hours and all fixed and
working well only changed two lamps on the port side
fwd facing floodlights, all now working ok.</column>
<column name="MaintLogID1">BRMR35029041</column>
</row>
<row>
<column name="Notes">Alarms tested satisfactory.</column>
<column name="MaintLogID1">BRMR35029042</column>
</row>
<row>
<column name="Notes">Alarms tested satisfactory </column>
<column name="MaintLogID1">BRMR35029043</column>
</row>
<row>
<column name="Notes">All indicators reading the same, all linkages
ok.</column>
<column name="MaintLogID1">BRMR35029044</column>
</row>
<row>
<column name="Notes">Tested alarm and operating on bridge but not
very loud. telephones tested and working.</column>
<column name="MaintLogID1">BRMR35029045</column>
</row>
<row>
<column name="Notes">Tested fire alarm detectors in two zones as
per pm instructions and all working satisfactory.
Findings recorded in electronic log.</column>
<column name="MaintLogID1">BRMR35029046</column>
</row>
<row>
<column name="Notes">Drilled hole in panel on bridge control consol
port side fwd facing to accomodate cable.
Attached plug on one end of cable and socket on other end secured socket to
panel on
bridge control console. Used the existing socket on the inspection lights
for inside the control panels
for supply to socket, plugged in and have 220 volts supply for laptop
computers. New installed
Socket posted with sign (220v supply for laptops only.)
</column>
<column name="MaintLogID1">BRMR35029047</column>
</row>
<row>
<column name="Notes">Removed exisitng magnetron and replaced with
spare. Found that the cables were short on the
new Kelvin Hughtes supplied magnetron for the Kelvin Hughes S band
manufactured Radar.
made cables longer by using some cable from old Magnetron. Baked magnetron
for 4 hours on standby,
then fired magnetron on short pulse for one hour. Took performance monitor
readings as per
instructions in Radar Manual that is on 12 mile range, long pulse and
measured 7.4 nm on plume,
recommeded between 6 and 8 nm, previous magnetron measuring 4 nm.
Good targets now being received. </column>
<column name="MaintLogID1">BRMR35029048</column>
</row>
<row>
<column name="Notes">Visually inspect and found operation
satisfactory.</column>
<column name="MaintLogID1">BRMR35029049</column>
</row>
<row>
<column name="Notes">Completed as per PM.
All operational and in good working order.</column>
<column name="MaintLogID1">BRMR35029050</column>
</row>
<row>
<column name="Notes">Visually inspected and operating
satisfactory.</column>
<column name="MaintLogID1">BRMR35029051</column>
</row>
<row>
<column name="Notes">Visually inspected and operating satisfactory.
New displays on order to fit on arrival</column>
<column name="MaintLogID1">BRMR35029052</column>
</row>
<row>
<column name="Notes">Visually inspected and operating
satisfactory.</column>
<column name="MaintLogID1">BRMR35029053</column>
</row>
<row>
<column name="Notes">Checked all indicators and all reading the
same.</column>
<column name="MaintLogID1">BRMR35029054</column>
</row>
<row>
<column name="Notes">No audible alarms, binnacle is free in its
shock mounts.
Not necessary to tighten screws on binnacle covers.
Wped down eterior of transmitters. Alignment of gyros are all
good.</column>
<column name="MaintLogID1">BRMR35029055</column>
</row>
<row>
<column name="Notes">No audible alarms, binnacle is free in its
shock mounts.
Not necessary to tighten screws on binnacle covers.
Wped down eterior of transmitters. Alignment of gyros are all
good.</column>
<column name="MaintLogID1">BRMR35029056</column>
</row>
<row>
<column name="Notes">Control air dryers changed over. No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35029057</column>
</row>
<row>
<column name="Notes">Control air dryers changed over. No 1 unit now
in use.</column>
<column name="MaintLogID1">BRMR35029058</column>
</row>
<row>
<column name="Notes">compressors changed over, No 3 unit now in
use.</column>
<column name="MaintLogID1">BRMR35029059</column>
</row>
<row>
<column name="Notes">compressors changed over, No 3 unit now in
use.</column>
<column name="MaintLogID1">BRMR35029060</column>
</row>
<row>
<column name="Notes">compressors changed over, No 3 unit now in
use.</column>
<column name="MaintLogID1">BRMR35029061</column>
</row>
<row>
<column name="Notes">compressors changed over, No 2 unit now in
use.</column>
<column name="MaintLogID1">BRMR35029062</column>
</row>
<row>
<column name="Notes">compressors changed over, No 2 unit now in
use.</column>
<column name="MaintLogID1">BRMR35029063</column>
</row>
<row>
<column name="Notes">2 bags bio aug added to sewage treatment
plant.</column>
<column name="MaintLogID1">BRMR35029064</column>
</row>
<row>
<column name="Notes">Filters cleaned as required</column>
<column name="MaintLogID1">BRMR35029065</column>
</row>
<row>
<column name="Notes">All fire flaps tested.</column>
<column name="MaintLogID1">BRMR35029066</column>
</row>
<row>
<column name="Notes">Alarm tested and OK.</column>
<column name="MaintLogID1">BRMR35029067</column>
</row>
<row>
<column name="Notes">Not cleaned as not been run.</column>
<column name="MaintLogID1">BRMR35029068</column>
</row>
<row>
<column name="Notes">Pump inspected and surveyed.
Mechanical seal renewed,
bottom line bearing renewed,
All wear rings 0.05mm clearance to impellars/shaft.
Test run and OK.</column>
<column name="MaintLogID1">BRMR35029069</column>
</row>
<row>
<column name="Notes">Pump inspected and surveyed.
Mechanical seal renewed,
bottom line bearing renewed,
All wear rings 0.05mm clearance to impellars/shaft.
Test run and OK.</column>
<column name="MaintLogID1">BRMR35029070</column>
</row>
<row>
<column name="Notes">C deck alleyway / laundry flap: release cable
snapped. Repaired & tested.
Wartsila email -
"From: johan.pellas@wartsila.com
Date: Wed, 17 Oct 2007 06:12 +0000 Msg: AMOS-100228172
Subject: RE: British Merchant.
To: ceng.merchant@bpfleet.com
Good morning
The opening set value for new and overhauled injection valves is 500bar.
Normally during operation the opening pressure is dropping about 50bar -
(100bar)
Regards
Johan Pellas"
</column>
<column name="MaintLogID1">BRMR35029082</column>
</row>
<row>
<column name="Notes">Pressures taken at 1200 kw.
Unit 1 2 3 4 5 6 7
8 9
Press 80 81 80 80 81 79 80
79 80
Fuel Rack 21 21 21 21 21 20 21
21 21
Exh Temp 285 293 291 265 276 271 275 270
283
</column>
<column name="MaintLogID1">BRMR35029083</column>
</row>
<row>
<column name="Notes">Hand pump overhauled and seals replaced.
</column>
<column name="MaintLogID1">BRMR35029084</column>
</row>
<row>
<column name="Notes">Completed as per work order.
</column>
<column name="MaintLogID1">BRMR35029085</column>
</row>
<row>
<column name="Notes">Carried out as per work order.
New Burns kit received for galley.
</column>
<column name="MaintLogID1">BRMR35029086</column>
</row>
<row>
<column name="Notes">All equipment checked as per work order and
found in good order</column>
<column name="MaintLogID1">BRMR35029087</column>
</row>
<row>
<column name="Notes">Equipment cheked as per work order and found
in good condition.
</column>
<column name="MaintLogID1">BRMR35029088</column>
</row>
<row>
<column name="Notes">Harnesses inspected as per work order and
found satisfactory.</column>
<column name="MaintLogID1">BRMR35029089</column>
</row>
<row>
<column name="Notes">Equiment greased as per work order and found
satisfactory.</column>
<column name="MaintLogID1">BRMR35029090</column>
</row>
<row>
<column name="Notes">All equiment greased as per work order and
found satisfactory.</column>
<column name="MaintLogID1">BRMR35029091</column>
</row>
<row>
<column name="Notes">Completed as per work order and found
satisfactory.</column>
<column name="MaintLogID1">BRMR35029092</column>
</row>
<row>
<column name="Notes">Rescusipac checked as per work order.
1 set still ashore being repaired, other set in hospital.</column>
<column name="MaintLogID1">BRMR35029093</column>
</row>
<row>
<column name="Notes">All rollers greased and proved free. All in
good condition with no wear or grooves.
</column>
<column name="MaintLogID1">BRMR35029094</column>
</row>
<row>
<column name="Notes">All vents drained, no water within.</column>
<column name="MaintLogID1">BRMR35029095</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029096</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029097</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029098</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029099</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029100</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029101</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029102</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029103</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029104</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029105</column>
</row>
<row>
<column name="Notes">Winch greased and tested as per work order. No
defects.</column>
<column name="MaintLogID1">BRMR35029106</column>
</row>
<row>
<column name="Notes">Bilges found dry and alarms tested
operational.</column>
<column name="MaintLogID1">BRMR35029107</column>
</row>
<row>
<column name="Notes">Bilges found dry and alarms tested
operational.</column>
<column name="MaintLogID1">BRMR35029108</column>
</row>
<row>
<column name="Notes">Tested as per work order and found
satisfactory.</column>
<column name="MaintLogID1">BRMR35029109</column>
</row>
<row>
<column name="Notes">Tested as per work order and found
satisfactory.</column>
<column name="MaintLogID1">BRMR35029110</column>
</row>
<row>
<column name="Notes">Operated as per work order and found
satisfactory.</column>
<column name="MaintLogID1">BRMR35029111</column>
</row>
<row>
<column name="Notes">The spares for the extinguishers were checked.
Non were found to be missing,
so nothing needed to be ordered.
All of the Co2 bottles are in date.
A list of spares can be foundin:-
1 LD Comp outlet temp A High High (TSHH 2A) 100 DegC Trip GC
314
Test procedure :- Reduce alarm set point to
below PV on IAS.
*****************************TRADER
ONLY***************************************************
1 LD Comp Bulk.Temp High High (TSHH 10) 80DegC Trip
Test procedure: - Disconnect PT100 at probe check resistance is
indicating correct temperature, use decade box to increase
resistance to alarm point (132ohm)
***************************************************************************
***********************
Ensure all set points are changed back to original settings on completion
of tests.
</column>
<column name="MaintLogID1">BRMR35029154</column>
</row>
<row>
<column name="Notes">The pressure regulator was removed.
Piston assembly removed and cleaned up. The o-rings where all in good
condition, but there was alot of muddy/rusty
rubbish inside the piston arrangment.
A new location pin was made and fitted for the feed back indication. This
was made out of brass due to the original
being plastic and was in bad condition.
Remove the top cover of the heater and reduce the alarm set point to below
the operating temp, return set point to normal on completion of test then
press green reset button, replace cover.
Generator shuts down.
Sounding Volumes
We have had to borrow the L.O Filter pressure Low-Low stat from No. 2 LD.
The stat fitted to this machine had
got moisture inside, and the cut in/out microswitch was seized. This was
made good but when we came to
readjust the set point we found the unit to be very unstable. It would trip
at different pressure's, evan though no
adjustment had been made to the positioning screw. Because of this a new
unit has been put on order and a
defect set up on amos.
Apart from the above all of the other trips and alarms are working
correctly.
1 HD Comp outlet temp A High High (TSHH 2A) 100 DegC Trip
GC 114
Test procedure :- Reduce alarm set point to below PV on IAS
***************************************************************************
***********************
</column>
<column name="MaintLogID1">BRMR35029205</column>
</row>
<row>
<column name="Notes">All of the below alarms and trips have been
tested. All were working correctly.
2 HD Comp outlet temp A High High (TSHH 2A) 100 DegC Trip
GC 214
Test procedure :- Reduce alarm set point to below PV on IAS
*****************************TRADER
ONLY***************************************************
2 HD Comp Bulk.Temp High High (TSHH 10) 80DegC Trip
Test procedure: - Disconnect PT100 at probe check resistance is
indicating correct temperature, use decade box to increase
resistance to alarm point (132ohm)
***************************************************************************
************************
2 HD Comp Seal Gas Press Low Low (PSLL 11) 15kpa Trip
GC 233 Actual - 14.8 Kpa
Test procedure:-Reduce set point on pressure regulator to
below trip point.
Interlock for manual winding leaver found to be incorrectly wired and not
operating as designed.
This has been rectified.
</column>
<column name="MaintLogID1">BRMR35029222</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029223</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029224</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029225</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029226</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029227</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029228</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029229</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029230</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029231</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029232</column>
</row>
<row>
<column name="Notes">Priming pump free to operate and turn.
Water level satisfactory.</column>
<column name="MaintLogID1">BRMR35029233</column>
</row>
<row>
<column name="Notes">Priming pump free to operate and turn.
Water level satisfactory.</column>
<column name="MaintLogID1">BRMR35029234</column>
</row>
<row>
<column name="Notes">Priming pump free to operate and turn.
Water level satisfactory.</column>
<column name="MaintLogID1">BRMR35029235</column>
</row>
<row>
<column name="Notes">Priming pump free to operate and turn.
Water level satisfactory.</column>
<column name="MaintLogID1">BRMR35029236</column>
</row>
<row>
<column name="Notes">Priming pump free to operate and turn.
Water level satisfactory.</column>
<column name="MaintLogID1">BRMR35029237</column>
</row>
<row>
<column name="Notes">All alarms and trips carried out as per P.M.
all satisfactory.</column>
<column name="MaintLogID1">BRMR35029238</column>
</row>
<row>
<column name="Notes">Unitor HP washer fitted with electrical
starter upgrade kit.
Washer and suitable saveall fitted in position, top of the engine room,
forward of the boiler air heaters.
Larger diameter fresh water supply line piped in from ship's domestic
FW system.
Unit tested and electrical load measured, gear case oil and pump water
temperatures measured whilst unit in operation.
Suitable operating instructions posted.
All operating parameters were found to be satisfactory.
For ref: Max gear case oil temperature measured at 75C.
</column>
<column name="MaintLogID1">BRMR35029239</column>
</row>
<row>
<column name="Notes">Checked all fire doors and magnetic
contactors.
Tested and found all to be fully functional.</column>
<column name="MaintLogID1">BRMR35029240</column>
</row>
<row>
<column name="Notes">Inspected and found to be working
satisfactory.</column>
<column name="MaintLogID1">BRMR35029241</column>
</row>
<row>
<column name="Notes">Visually inspected and found to be operated
satisfactory.
Ship at anchor no readings</column>
<column name="MaintLogID1">BRMR35029242</column>
</row>
<row>
<column name="Notes">Checked the operation of the system and
working satisfactory. All illuminations correct.</column>
<column name="MaintLogID1">BRMR35029243</column>
</row>
<row>
<column name="Notes">Checked the operation of the system and
working satisfactory. All illuminations correct.</column>
<column name="MaintLogID1">BRMR35029244</column>
</row>
<row>
<column name="Notes">All operating satisfactory.
Tested weekly& all tests carried out satisfactory.</column>
<column name="MaintLogID1">BRMR35029245</column>
</row>
<row>
<column name="Notes">Sytem fully operational and no faults
reported.</column>
<column name="MaintLogID1">BRMR35029246</column>
</row>
<row>
<column name="Notes">New above decks unit on order. As display of
wind direction only on port half of vessel.
Speed indication is ok.</column>
<column name="MaintLogID1">BRMR35029247</column>
</row>
<row>
<column name="Notes">Completed as per PM.
System operating satisfactory.
New displays on order.</column>
<column name="MaintLogID1">BRMR35029248</column>
</row>
<row>
<column name="Notes">Thank you John,
I was awaiting some feedback from our local service station, but you
have beat them to it. I'll find out if they have anything to add to
this
and send you an update.
Kind Regards,
Ross
-----Original Message-----
From: British Merchant - Chief Engineer
[mailto:ceng.merchant@bpfleet.com]
Sent: Thursday, October 25, 2007 9:31 PM
To: Freeman, Ross
Cc: Parker, Mike
Subject: Re: CO2 Fixed System.
G'Day Ross,
A quick heads up, a Unitor service technician attended the vessel today,
in order to resolve the issue a suitable plug has been fitted to blank off
the air blow connection.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
Hi Ross,
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: Freeman, Ross
Date: Fri, 19 Oct 2007 15:53 +0000 Msg: AMOS-100542159
Subject: RE: CO2 Fixed System.
To: British Merchant - Chief Engineer
Hello John,
Just to update you, our coordinating office have advises that based on
the current schedule and vessel location we will not be able to attend
to perform the service.
However, I understand that the schedule may change so I have asked that
our local representatives stay in touch with the agent to ensure that if
the opportunity arises to attend we do so.
Please reply to this email with any changes in itinerary. Thank you.
Kind Regards,
Ross Freeman
-----Original Message-----
From: British Merchant - Chief Engineer
[mailto:ceng.merchant@bpfleet.com]
Sent: Tuesday, October 16, 2007 8:34 PM
To: Freeman, Ross
Cc: Parker, Mike (BP Shipping)
Subject: Re: CO2 Fixed System.
G'Day Ross,
MELVILLE SHIPPING
18/20 London Street
PO Box 772
Port of Spain
Trinidad, WI
Phone 1: +1868 625 4977
Telex: 22265
Fax: +1868 623 2162
Phone 2: +1868 625 4287
Email: melops@neal-and-massy.com <mailto:melops@neal-and-massy.com>
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
-----
From: Freeman, Ross
Date: Tue, 16 Oct 2007 16:43 +0000 Msg: AMOS-100171744
Subject: RE: CO2 Fixed System.
To: British Merchant - Chief Engineer
Hello John,
I have taken the matter up with our local Service Manager in the UK who
has been available this week, and from the pictures he feels that the
arrangement is not correct.
The best way of resolving this is to send one of our technicians onboard
to verify the set-up and make alterations where necessary. Please
confirm your current schedule and agents so that we may make
arrangements for attendance.
Kind Regards,
Ross Freeman
-----
From: British Merchant - Chief Engineer
Date: Sat, 29 Sep 2007 21:51 +0000 Msg: VQIB9-145235
Subject: CO2 Fixed System.
To: Soul, Lindsey
Cc: Parker, Mike \(BP Shipping\)
Hi Lindsey,
During routine inspection of the fixed CO2 system for the cargo
machinery, it was noted that the air test arrangement is missing, please
see attached
photo and CO2 room arrangement drawing.
The connection is fitted with a non-return valve, however the pipe end
is open.
Would not really expect to see a valve and test connection fitted on the
However, consider that the open pipe end should be at least blanked off,
since
if the system is activated and the non-return valve passes, CO2 will
pass into
the CO2 room.
Please advise.
FYR: Last annual inspection of vessels fixed CO2 system was carried out
by Unitor in Singapore 10/03/07.
Best regards
John Rigg
CHIEF ENGINEER
LNGC British Merchant
VSat Phone:
+44 1932 443241 (General Office)
+44 1932 443240 (Bridge Deck)
Sat B phone: +870 323 563710
Sat B Fax : +870 323 563714
E-Mail: ceng.merchant@bpfleet.com
</column>
<column name="MaintLogID1">BRMR35029249</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029250</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029251</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029252</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029253</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029254</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029255</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029256</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029257</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029258</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029259</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029260</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029261</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029262</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029263</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029264</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029265</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds surveyor.</column>
<column name="MaintLogID1">BRMR35029266</column>
</row>
<row>
<column name="Notes">Checked rudder bonding cable.
Checked and cleaned shaft earthing device slip ring and brush
gear.</column>
<column name="MaintLogID1">BRMR35029267</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029268</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029269</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029270</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029271</column>
</row>
<row>
<column name="Notes">Completed along with the testing of the trips
and alarms. WO. MER/07/04545.
All Entek readings have been taken.
A running log has been entered onto the gas engineers desk top.
The IGG unit has been run on both dry air and the IG mode.
You can visably see water leaking from the upper two furnace flame
inspection holes.
The dryer unit fan was leaking IG out from the seal between the fan casing
and the drive shaft. This will be
put down as a defect and repaired prior to the next time the unit is run.
</column>
<column name="MaintLogID1">BRMR35029272</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029273</column>
</row>
<row>
<column name="Notes">As per instructions shorted out terminals 11
and 12 also 21 and 22 on the thermostat.
Thermostat safety activated at 221deg C on the stbd side and on port side
measured 220 deg C.
Safties reset and checked thermostat operation after oil had cooled down
and both operating
satisfactory.</column>
<column name="MaintLogID1">BRMR35029274</column>
</row>
<row>
<column name="Notes">Turned on both fryer.Set thermoststs on both
fryer one at 150 deg and one at 130 deg.
Checked with thermometer & both thermostats cut out at 5 deg's
below setting.</column>
<column name="MaintLogID1">BRMR35029275</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029276</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029277</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029278</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029279</column>
</row>
<row>
<column name="Notes">Opened up the unit.
The unside was very clean.
The only defect to report is that there is pin holes on the water jacket.
These are located on the two upper flame inspection
holes. When the unit was being tested you could see the water jetting out
of these holes.
A dry dock spec has been made up for this so it should be repaired in the
2008 docking.</column>
<column name="MaintLogID1">BRMR35029280</column>
</row>
<row>
<column name="Notes">The O2 cell was calibrated using 2% span gas.
No problems where incured while calibrating the unit.</column>
<column name="MaintLogID1">BRMR35029281</column>
</row>
<row>
<column name="Notes">The O2 cell was calibrated along with WO
MEr/07/05522.
The freon level, blowers etc where all good.
FO filter handle turned
</column>
<column name="MaintLogID1">BRMR35029282</column>
</row>
<row>
<column name="Notes">Completed as per the PM.Unit was tested during
the running of the IGG.</column>
<column name="MaintLogID1">BRMR35029283</column>
</row>
<row>
<column name="Notes">Completed as per the PM.Unit was tested during
the running of the IGG.
Unit was tested with the shaw meter, all is good.</column>
<column name="MaintLogID1">BRMR35029284</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029285</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029286</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029287</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029288</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029289</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029290</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029291</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029292</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029293</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029294</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029295</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029296</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029297</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029298</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029299</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029300</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029301</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029302</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029303</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029304</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029305</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029306</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029307</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029308</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029309</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029310</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029311</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029312</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029313</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029314</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029315</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029316</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029317</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029318</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029319</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029320</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029321</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029322</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029323</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029324</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029325</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029326</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029327</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029328</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029329</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029330</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029331</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029332</column>
</row>
<row>
<column name="Notes">All lights swiched onat night all fixed and
working well .</column>
<column name="MaintLogID1">BRMR35029333</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029334</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029335</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029336</column>
</row>
<row>
<column name="Notes">No defects reported</column>
<column name="MaintLogID1">BRMR35029337</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029338</column>
</row>
<row>
<column name="Notes">DSC tested by 3rd officer. All working
ok</column>
<column name="MaintLogID1">BRMR35029339</column>
</row>
<row>
<column name="Notes">Sliding feet greased</column>
<column name="MaintLogID1">BRMR35029340</column>
</row>
<row>
<column name="Notes">Sliding feet greased</column>
<column name="MaintLogID1">BRMR35029341</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029342</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029343</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029344</column>
</row>
<row>
<column name="Notes">Alarms tested satisfactory </column>
<column name="MaintLogID1">BRMR35029345</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029346</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029347</column>
</row>
<row>
<column name="Notes">Alarms tested satisfactory.</column>
<column name="MaintLogID1">BRMR35029348</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029349</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029350</column>
</row>
<row>
<column name="Notes">Alarms and phone tested satisfactory</column>
<column name="MaintLogID1">BRMR35029351</column>
</row>
<row>
<column name="Notes">Checked all indicators and all reading the
same.</column>
<column name="MaintLogID1">BRMR35029352</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029353</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029354</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029355</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029356</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029357</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029358</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029359</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029360</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029361</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029362</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029363</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029364</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029365</column>
</row>
<row>
<column name="Notes">All Vessels Lifejackets and Safety Helmets
checked as per PM. All helmets in date and in good condition. All Rigid
Lifejackets checked and found in good condition, all lights
replaced.</column>
<column name="MaintLogID1">BRMR35029366</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029367</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029368</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029369</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029370</column>
</row>
<row>
<column name="Notes">All Immersion suits/Boat suits/Winter suits
checked and found in good condition. All in correct location and dry. Still
small light on suit 2875. Still awaiting new light for one suit.</column>
<column name="MaintLogID1">BRMR35029371</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029372</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029373</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029374</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029375</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029376</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029377</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029378</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029379</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029380</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029381</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029382</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029383</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029384</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029385</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029386</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029387</column>
</row>
<row>
<column name="Notes">Completed as per WO. All in good
order.</column>
<column name="MaintLogID1">BRMR35029388</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029389</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029390</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029391</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029392</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029393</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029394</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029395</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029396</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029397</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029398</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029399</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029400</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029401</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029402</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029403</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029404</column>
</row>
<row>
<column name="Notes">Equipment inspected to the satisfaction of the
attending Lloyds Surveyor.</column>
<column name="MaintLogID1">BRMR35029405</column>
</row>
<row>
<column name="Notes">One man bridge alarm tested as per weekly work
order.
Duty set to 2/O cabin. Watch call, All Call and duty call tested.
One man Bridge timer operated correctly.</column>
<column name="MaintLogID1">BRMR35029406</column>
</row>
<row>
<column name="Notes">Monthly inspection of lifeboat carried out.
All in good, operational condition, all loose equipment in place and all
items up to date.</column>
<column name="MaintLogID1">BRMR35029407</column>
</row>
<row>
<column name="Notes">Monthly inspection of lifeboat carried out.
Painter replaced to a new one due to being worn.
All in good, operational condition, all loose equipment in place and all
items up to date.</column>
<column name="MaintLogID1">BRMR35029408</column>
</row>
<row>
<column name="Notes">Tested two areas route 10 and 11 all heads
tested working satisfactory. Fire system put back to
normal condition and bridge informed. One head situated over 6.6 kv
transformer, deemed unsafe to
test.</column>
<column name="MaintLogID1">BRMR35029409</column>
</row>
<row>
<column name="Notes">Flame eye and air inlets clean</column>
<column name="MaintLogID1">BRMR35029410</column>
</row>
<row>
<column name="Notes">Alarm tested and OK.</column>
<column name="MaintLogID1">BRMR35029411</column>
</row>
<row>
<column name="Notes">Dryers changed over No 1 now in use.</column>
<column name="MaintLogID1">BRMR35029412</column>
</row>
<row>
<column name="Notes">Dryers changed over No 1 now in use.</column>
<column name="MaintLogID1">BRMR35029413</column>
</row>
<row>
<column name="Notes">Compressors changed over No 3 now in
use.</column>
<column name="MaintLogID1">BRMR35029414</column>
</row>
<row>
<column name="Notes">Compressors changed over No 3 now in
use.</column>
<column name="MaintLogID1">BRMR35029415</column>
</row>
<row>
<column name="Notes">Compressor out of order.</column>
<column name="MaintLogID1">BRMR35029416</column>
</row>
<row>
<column name="Notes">Compressors changed over No 2 now in
use.</column>
<column name="MaintLogID1">BRMR35029417</column>
</row>
<row>
<column name="Notes">Compressors changed over No 2 now in
use.</column>
<column name="MaintLogID1">BRMR35029418</column>
</row>
<row>
<column name="Notes">1 bag bio aug dosed to sewage treatment
plant.</column>
<column name="MaintLogID1">BRMR35029419</column>
</row>
<row>
<column name="Notes">Cleaned as required.</column>
<column name="MaintLogID1">BRMR35029420</column>
</row>
<row>
<column name="Notes">Alarm tested and OK.</column>
<column name="MaintLogID1">BRMR35029421</column>
</row>
<row>
<column name="Notes">Fire hoses tested in rotation.</column>
<column name="MaintLogID1">BRMR35029422</column>
</row>
<row>
<column name="Notes">filters cleaned</column>
<column name="MaintLogID1">BRMR35029423</column>
</row>
<row>
<column name="Notes">filters cleaned</column>
<column name="MaintLogID1">BRMR35029424</column>
</row>
<row>
<column name="Notes">Monthly inspection of pyrotechnics carried
out.
All found in good shape and up to date.</column>
<column name="MaintLogID1">BRMR35029425</column>
</row>
<row>
<column name="Notes">All extinguishers were visually cheched. The
extinguishers were then weighed and
the weight was then recorded. The mounting brackets were then inspected,
all found
to be in good condition. The survey dates were then checked.
All recorded informayion can be found @ T:/ Engineering
Department/JE/Fire Equipment & Dampers/2007/Fire Extinguishers.xls
Note:- The extinguishers on D deck were not listed in the above folder and
subsequently have not been inspected since May 07.
This has now been rectified.</column>
<column name="MaintLogID1">BRMR35029426</column>
</row>
<row>
<column name="Notes">All points greased on M/T manouvering valves.
This was completed in port with the main turbine tripped.
High temperature grease was not used because it is unneccessary as the
manouvering gear does not reach
a temparature high enough to liquify the lubricant.
</column>
<column name="MaintLogID1">BRMR35029427</column>
</row>
<row>
<column name="Notes">The sludge pump was lubricated and inspected
visually.
All were in good condition.</column>
<column name="MaintLogID1">BRMR35029428</column>
</row>
<row>
<column name="Notes">PORT PASSAGEWAY BILGES TESTED AND FOUND ALL
WORKING OK.
FORECASTLE, FWD PUMP ROOM, AND BOW THRUSTER ROOM
BILGES TESTED AND FOUND WORKING OK.
ALL INSPECTED BILGE WELLS CLEAN AND DRY. </column>
<column name="MaintLogID1">BRMR35029429</column>
</row>
<row>
<column name="Notes">STBD PASSAGEWAY BILGES TESTED AND FOUND ALL
WORKING OK.
FORECASTLE, FWD PUMP ROOM, AND BOW THRUSTER ROOM
BILGES TESTED AND FOUND WORKING OK.
ALL INSPECTED BILGE WELLS CLEAN AND DRY. </column>
<column name="MaintLogID1">BRMR35029430</column>
</row>
<row>
<column name="Notes">All satisfactory.</column>
<column name="MaintLogID1">BRMR35029431</column>
</row>
<row>
<column name="Notes">Generator sump purified.</column>
<column name="MaintLogID1">BRMR35029432</column>
</row>
<row>
<column name="Notes">Tested as per rota - no defects
reported</column>
<column name="MaintLogID1">BRMR35029433</column>
</row>
<row>
<column name="Notes">Tested as per rota - no defects
reported</column>
<column name="MaintLogID1">BRMR35029434</column>
</row>
<row>
<column name="Notes">Fond damage electric motor. DE bearing and
cover broken. Damage windings and insulation 0 MOhm.
Install spare electric motor test and all back to normal working condition.
Details of motor.
Old:
Hyunday
Model: WV121MS
0.75 kW 1710RPM
440V frame 80
60Hz 1.7A
New:
Fuji Electric
MLA6085D
075kW 1720RPM
440V frame 80M
60Hz 1.6A</column>
<column name="MaintLogID1">BRMR35029435</column>
</row>
<row>
<column name="Notes">All tested and found working OK.</column>
<column name="MaintLogID1">BRMR35029436</column>
</row>
<row>
<column name="Notes">Motor operated and found to be working OK. In-
line lubricator adjusted. Before starting approx 0,5 l of
water had to be drained off from air line.
Manual handle operation tested and found working OK. All well
greased.</column>
<column name="MaintLogID1">BRMR35029437</column>
</row>
<row>
<column name="Notes">Motor operated and found to be working OK. In-
line lubricator adjusted. Before starting approx 0,5 l of
water had to be drained off from air line.
Manual handle operation tested and found working OK. All well
greased.</column>
<column name="MaintLogID1">BRMR35029438</column>
</row>
<row>
<column name="Notes">Wire slackened down ad grease cleaned off for
inspection.Found in good condition,
no signs of damage to the core or outer layers,terminations in good
condition.
Grease reapplied and ladder tested before returning to service.</column>
<column name="MaintLogID1">BRMR35029439</column>
</row>
<row>
<column name="Notes">Wire slackened down ad grease cleaned off for
inspection.Found in good condition,
no signs of damage to the core or outer layers,terminations in good
condition.
Grease reapplied and ladder tested before returning to service.</column>
<column name="MaintLogID1">BRMR35029440</column>
</row>
<row>
<column name="Notes">Spiner checked and foud problem with control
PCB.
New PCB in order. </column>
<column name="MaintLogID1">BRMR35029441</column>
</row>
<row>
<column name="Notes">Pilot ladder inspected as per PM.
In line air lubricator adjusted - found to be filled with water and only 1
cm of oil on the top - oil changed
( water comming from air line). Oil found leaking from the gear box sight
glass - area around cleaned up and repair carried out
with thissle bond.Gear box oil changed.
Manual handle operation tested and found to be working OK.
Ladder in good condition - ropes and steps inspected all OK. </column>
<column name="MaintLogID1">BRMR35029442</column>
</row>
<row>
<column name="Notes">Pilot ladder inspected as per PM.
In line air lubricator adjusted - found to be half filled with water - oil
changed
( water comming from air line). .Gear box oil changed.
Manual handle operation tested and found to be working OK.
Ladder in good condition - ropes and steps inspected all OK. Minor repairs
noticed on bottom
spreader - still in good condition fot use </column>
<column name="MaintLogID1">BRMR35029443</column>
</row>
<row>
<column name="Notes">Wire greased after 24M inspection DK90005 WO
MER/07/04183
Wire to be replaced before MARCH 2008 ( 30 MOTHS IN SERVICE)</column>
<column name="MaintLogID1">BRMR35029444</column>
</row>
<row>
<column name="Notes">Wire greased after 24M inspection DK90005 WO
MER/07/04182
Wire to be replaced before MARCH 2008 ( 30 MOTHS IN SERVICE)</column>
<column name="MaintLogID1">BRMR35029445</column>
</row>
<row>
<column name="Notes">E/R spray pump started from FCC and alll areas
checked for blockages.
All blocked nozzles recorded and cleaned up afterwards.Nozzles blocked by
mixture of various crushed sea shells.
Spray brach going under Compressor house found holed in four places along
the lenght of the pipe.
Reported to C/E - possible DD spec.
Pump vibration level measured during test</column>
<column name="MaintLogID1">BRMR35029446</column>
</row>
<row>
<column name="Notes">Steering Flat spray pump started from FCC and
water delivered at sufficient pressure to both lifeboat spray nozzles.
All blocked nozzles recorded and cleaned up afterwards.Nozzles blocked by
mixture of various crushed sea shells.
Tank 3. Clean. Anodes showing signs of wastage. Amps correct. Suitable for
further use.
</column>
<column name="MaintLogID1">BRMR35029453</column>
</row>
<row>
<column name="Notes">Tank 1 clean. Anodes showing signs of wastage
(severe on one or two) but amps still correct. Suitable
for further use.
Tank 3. Clean. Anodes showing signs of wastage. Amps correct. Suitable for
further use.</column>
<column name="MaintLogID1">BRMR35029454</column>
</row>
<row>
<column name="Notes">No 2 pump run up to speed. Oil pressure
satisfactory.</column>
<column name="MaintLogID1">BRMR35029455</column>
</row>
<row>
<column name="Notes">No 2 pump run up to speed. All pressures and
temps correct.</column>
<column name="MaintLogID1">BRMR35029456</column>
</row>
<row>
<column name="Notes">Pump started using remote start all
satisfactory.</column>
<column name="MaintLogID1">BRMR35029457</column>
</row>
<row>
<column name="Notes">Generator started using battery start all
satisfactory.</column>
<column name="MaintLogID1">BRMR35029458</column>
</row>
<row>
<column name="Notes">Genrator run as part of I.G alarms and trips.
All temps and pressures correct.</column>
<column name="MaintLogID1">BRMR35029459</column>
</row>
<row>
<column name="Notes">All sets and cylinders inspected and
satisfactory.</column>
<column name="MaintLogID1">BRMR35029460</column>
</row>
<row>
<column name="Notes">Priming pump free to turn and water level
correct.</column>
<column name="MaintLogID1">BRMR35029461</column>
</row>
<row>
<column name="Notes">Priming pump free to turn and water level
correct.</column>
<column name="MaintLogID1">BRMR35029462</column>
</row>
<row>
<column name="Notes">Priming pump free to turn and water level
correct.</column>
<column name="MaintLogID1">BRMR35029463</column>
</row>
<row>
<column name="Notes">Priming pump free to turn and water level
correct.</column>
<column name="MaintLogID1">BRMR35029464</column>
</row>
<row>
<column name="Notes">Priming pump free to turn and water level
correct.</column>
<column name="MaintLogID1">BRMR35029465</column>
</row>
<row>
<column name="Notes">All checked and found to be moving freely, 24
wire inspection carried out - wire greased,
gearbox oil level checked and found to be OK .
Air motor inspected as per separate WO
All well greased.</column>
<column name="MaintLogID1">BRMR35029466</column>
</row>
<row>
<column name="Notes">All checked and found to be moving freely, 24
wire inspection carried out - wire greased,
gearbox oil level checked and found to be OK .
Air motor inspected as per separate WO
All well greased.</column>
<column name="MaintLogID1">BRMR35029467</column>
</row>
<row>
<column name="Notes">The tank high level alarm was tested
successfully, however the test lever on the mobrey float
could not be used as there is not one.</column>
<column name="MaintLogID1">BRMR35029468</column>
</row>
<row>
<column name="Notes">The tank high level alarm was tested
successfully, however the test lever on the mobrey float
could not be used as there is not one.</column>
<column name="MaintLogID1">BRMR35029469</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029470</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029471</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029472</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029473</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029474</column>
</row>
<row>
<column name="Notes">The high level alarm was tested successfully
using the mobrey float.</column>
<column name="MaintLogID1">BRMR35029475</column>
</row>
<row>
<column name="Notes">Air motor removed to workshop. Diaphragm
checked and in good condition. Motor rotates smoothly.
Tested and operating satisfactorily. Motor refitted.
Tank filled with water and pump operated. Pump running at 7A.
1) Flame Failure (XZA 2021): Close the fuel oil shut off valve 1051.
3) Fuel Oil Pressure Low (PZAL 1053) Set Point: 10 bar WAS 8 BAR.
ADJUSTED TO 10 BAR
Slowly close in on fuel oil shut off valve 1051.
Alternative:
Connect Druck to pressure switch, increase pressure to above set point
open
Druck to pressure switch and reduce pressure to alarm point.
4) Steam Pressure Low (PZAL 1634) Set Point: 1.8 bar WAS 2.6 BAR
6) Combustion Air Pressure High (PZAH 2010) Set Point: 0.45 bar
Reduce set point on pressure switch to operating PV, reset to
original setting after test.
Alternative:
Connect Druck to pressure switch and increase pressure to alarm point.
8) Scrubber Tower CW Inlet Pressure Low (PZAL 2320) Set Point: 1.5 bar
Increase set point on pressure switch to operating PV, reset to
original setting after test.
Alternative:
Connect Druck to pressure switch, increase pressure to above set point
open Druck to pressure switch and reduce pressure to alarm point.
10) Jacket CW Pressure High (PZAH 2321) Set Point: 1.0 bar
Reduce set point on pressure switch to operating PV, reset to
original setting after test.
Alternative:
Connect Druck to pressure switch and increase pressure to alarm point.
13) IG Pressure after Scrubber Tower High (PZAH 4410) Set Point: 0.4 bar
Reduce set point on pressure switch to operating PV, reset to
original setting after test.
Alternative:
Connect Druck to pressure switch and increase pressure to alarm
point.
14) IG Temperature after Cooler High (TZAH 4402) Set Point: 7 DegC
Reduce set point on temperature switch to operating temp, reset to
original setting after test.
Alternative:
Remove temperature probe immerse in cold water and allow to rise
above set point.
15) IG Temperature after Cooler Low (TZAL 4403) Set Point: 0 DegC
Increase set point on temperature switch to operating temp, reset to
original setting after test.
Alternative:
Remove temperature probe and immerse in ice water.
16) R404 Compressor LP Cut Out (PZAL 4003) Set Point: 1.5 bar
With the compressor running slowly close in on the suction valve.
17) R404 Compressor HP Cut Out (PZAH 4006) Set Point: 21 bar
With IG plant running, slowly close in on the cooling water outlet
valve.
Alternative:
Reduce pressure switch setting to below operating pressure, return to
original
setting after test.
18) R404 Compressor CW Pressure Low (PZAL 4328) Set Point: 1.0 bar WAS
1.7 BAR
19) R404 Compressor Lub Oil Pressure Low (DPZAL 4024) Set Point: 1.5 bar
With the compressor running, remove the cover from the pressure
switch
and hold down the test switch. There is a 60 second delay before the
trip is
activated.
28) Dryer Control Air Pressure Low (PZAL 5305) Set Point: 5.0 bar WAS
6 bar
ADJUSTED TO 5 bar
Close the control Air shut off valve 5301, bleed off pressure.
29) Dryer Valve Position Failure
Depending on which vessel is in operation, manually open the outlet
valve
5081 or 5091 on the vessel not in use.
30) Dew point High (QAH 7101) Set Point: -40 DegC
Remove probe inlet pipe and backflow through outlet pipe with
aspirator.
31) IG Delivery Pressure High (PAH 6053) Set Point: 0.25 bar
WAS 0.3 bar
</column>
<column name="MaintLogID1">BRMR35029478</column>
</row>
<row>
<column name="Notes">Vacuum pump fully overhauled, all parts found
to be in a good condition.
Pump run under operating conditions, all operating parameters and vibration
readings found to be normal.
Discharge Pressure: 5.5bar.
Motor Load: 201amps.
Total Running Hours: 6hrs.
</column>
<column name="MaintLogID1">BRMR35029479</column>
</row>
<row>
<column name="Notes">The high level alrm was tested successfully,
but there was no test lever on the
mobrey float to utilise.</column>
<column name="MaintLogID1">BRMR35029480</column>
</row>
<row>
<column name="Notes">This task was completed by the 2nd
eng.</column>
<column name="MaintLogID1">BRMR35029481</column>
</row>
<row>
<column name="Notes">This task was completed by the 2nd
eng.</column>
<column name="MaintLogID1">BRMR35029482</column>
</row>
<row>
<column name="Notes">Awaiting spare solenoids to allow correct
operation of #1 unit.
#2 unit operating within parameters. Not opened up. This inspection can be
carried out once #1 unit
operating correctly.</column>
<column name="MaintLogID1">BRMR35029483</column>
</row>
<row>
<column name="Notes">#2 T/A gearing inspected. Gear teeth showing
even contact. No evidence of pitting or scuffing.
Gas Low-Low trip: Tested using the common gas temp probe (Not the
individual blr gas temp probes)
Gas pressure low-low/high-high: use transmitter labelled BP PX122 (NOT 123
as stated on PM)
Blr hdr N2 vent v/v open: easier to simply remove the limit switch plate in
order to activate trip.
Also Duty Navigation officer call and All Navigation officer call tested.
Note the fan casing and mushroom vent is starting to require a bit of
fabric maintenance. </column>
<column name="MaintLogID1">BRMR35029602</column>
</row>
<row>
<column name="Notes">Completed as part of the 36 month PM.</column>
<column name="MaintLogID1">BRMR35029603</column>
</row>
<row>
<column name="Notes">Completed as part of the 36 month
overhaul.</column>
<column name="MaintLogID1">BRMR35029604</column>
</row>
<row>
<column name="Notes">Hydraulic filter opened up. The cartridge was
inspected and found to be spotless. It was re-fitted because of
this.</column>
<column name="MaintLogID1">BRMR35029605</column>
</row>
<row>
<column name="Notes">Found No.2 AC compressor motor earthed.
Compressor disconnected. After investigation by 2ENG decide to order 2 new
compressor.
New compressor in order.MER/07/00405</column>
<column name="MaintLogID1">BRMR35029606</column>
</row>
<row>
<column name="Notes">Work carried out on 30.6.07</column>
<column name="MaintLogID1">BRMR35029607</column>
</row>
<row>
<column name="Notes">Work carried out 30.5.07</column>
<column name="MaintLogID1">BRMR35029608</column>
</row>
<row>
<column name="Notes">Work carried out 8.12.06</column>
<column name="MaintLogID1">BRMR35029609</column>
</row>
<row>
<column name="Notes">All operating satisfactorily.</column>
<column name="MaintLogID1">BRMR35029610</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029611</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029612</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029613</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029614</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029615</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029616</column>
</row>
<row>
<column name="Notes">Lub oil changed & sump sight glass
cleaned. LO filter cleaned. No metallic particles found.
</column>
<column name="MaintLogID1">BRMR35029617</column>
</row>
<row>
<column name="Notes">New display unit installed.
GPS tested anf found in good working condition.</column>
<column name="MaintLogID1">BRMR35029618</column>
</row>
<row>
<column name="Notes">New display unit installed.
GPS tested anf found in good working condition.</column>
<column name="MaintLogID1">BRMR35029619</column>
</row>
<row>
<column name="Notes">New display unit installed.
GPS tested anf found in good working condition.</column>
<column name="MaintLogID1">BRMR35029620</column>
</row>
<row>
<column name="Notes">New display unit installed.
GPS tested anf found in good working condition.</column>
<column name="MaintLogID1">BRMR35029621</column>
</row>
<row>
<column name="Notes">All 64 dry powder extinguishers were visually
checked for any
abnormalities. The extinguisher's were then agitated, loosening
the powder. The screw cover was checked to be tight and then
the extinguisher was signed.</column>
<column name="MaintLogID1">BRMR35029622</column>
</row>
<row>
<column name="Notes">Chandlers unable to source flared connection
nuts. Repaired using suitable alternative.
System pressurised and no leakage evident.
All call and duty call tested, and all Nav officer cabins alarmed after 3
min delay.
*****************************************
PLEASE READ BELOW
To sum up, if the repair can be made without resorting to using local
control, then please proceed but follow the below guideline - this
wording will appear in the AMOS M&P interim lift maintenance Jobs that
should be sent out soon.
QUOTE:-
This inspection cannot be done without a JHA, the content of which
should be read and fully understood before starting work.
Therefore gain access to the cab top via the cabs emergency escape
hatch, and rather than ride the cab, move the cab by normal operation to
required decks in turn. When on top of the cab take local control as
described in the manufacturer's manual, and in addition activate the
Emergency Stop button/switch on the cab top.
Best regards
Richard
Richard Thomas
Project coordinator - Fleet Technical (Gas) BP Shipping,
>Desk W108, Building G/1st Floor,
>Chertsey Road,
>Sunbury-on-Thames,
>Middlesex,
>TW16 7LN
</column>
<column name="MaintLogID1">BRMR35029758</column>
</row>
<row>
<column name="Notes">Fan opened up for a 36 month PM.
See MER/06/90041 for details.
The only defect with the unit apart from the fabric condition of the
outside casing, was the motor cooling fan
protective casing was badly corroded away. We didn't have a spare so
we have fabricated a new, stronger one.
There was no need to change the bearings or lip seals due to them being in
good condition.</column>
<column name="MaintLogID1">BRMR35029761</column>
</row>
<row>
<column name="Notes">Coupling was opened up, cleaned and inspected.
There are signs of wear on all components. But the general
condition is good engough to last another year. The coupling may need
replacing after the next 12 monthly inspection.
New grease was applied to the coupling and the pump was put back on load.
Spares used
The low current timer ( 37LT ) was set to 6 seconds. I readjusted it back
to match the other pumps at 10 seconds.
The low level timer was set to 6 seconds. I've left it at this due to
this being the last pump used while heeling out.
</column>
<column name="MaintLogID1">BRMR35029780</column>
</row>
<row>
<column name="Notes"> # 1 O2 -
LEL
Liquid Dome IBS CN 130 1.0% - 0%
OTU unit checked as well and found to be in good working condion. O2 bottle
pressure 130 Bar. </column>
<column name="MaintLogID1">BRMR35029797</column>
</row>
<row>
<column name="Notes">All fairleads turned and greased. All proved
to be moving freely.</column>
<column name="MaintLogID1">BRMR35029798</column>
</row>
<row>
<column name="Notes">Winch greased and tested - all working OK.
Clutch lever bent - separate defect work order issued. Lever removed fixed
and coated - waiting for the final coat
before fitting back.
Port anchor not used recently so unable to determine if anything changed
with regards to problem with clutch dissengaging while
lifting up anchor.
Possible leak from under one of the bearing covers - separate work order to
be issued
Correct oil level.
Operated from all control stands and found to be working OK.
Brake oil pots checked and found with correct oil level.
</column>
<column name="MaintLogID1">BRMR35029801</column>
</row>
<row>
<column name="Notes">Tested and found OK - check report for
7.2203.03</column>
<column name="MaintLogID1">BRMR35029802</column>
</row>
<row>
<column name="Notes">Winch greased and tested - all working OK.
Correct oil level.
Operated from all control stands and found to be working OK.
Brake oil pots checked and found with correct oil level.
Brake oil pots checked and found with correct oil level.
Hoses in good condition. Fittings covered with DENSO tape and found to be
in good condition (spot check)
Brake oil pots checked and found with correct oil level.
Hoses in good condition. Fittings covered with DENSO tape and found to be
in good condition (spot check)
Brake oil pots checked and found with correct oil level.
Hoses in good condition. Fittings covered with DENSO tape and found to be
in good condition (spot check)
Brake oil pots checked and found with correct oil level.
Hoses in good condition. Fittings covered with DENSO tape and found to be
in good condition (spot check)
Brake oil pots checked and found with correct oil level.
Hoses in good condition. Fittings covered with DENSO tape and found to be
in good condition (spot check)
Brake oil pots checked and found with correct oil level.
Vent flap interlock working OK.
</column>
<column name="MaintLogID1">BRMR35029809</column>
</row>
<row>
<column name="Notes">Equipment is operating satisfactorily.
There are no reported defects with this equipment at this time.</column>
<column name="MaintLogID1">BRMR35029810</column>
</row>
<row>
<column name="Notes">Drain line inspected and found badly corroded
internally. New section of pipe fabricated and fitted.</column>
<column name="MaintLogID1">BRMR35029811</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029812</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029813</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029814</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029815</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029816</column>
</row>
<row>
<column name="Notes">All burner units were changed for clean. The
dirty units were then
cleaned and the teflon rings were replaced.</column>
<column name="MaintLogID1">BRMR35029817</column>
</row>
<row>
<column name="Notes">All v/v's on air recievers found to be
free to move through
there full travel.</column>
<column name="MaintLogID1">BRMR35029818</column>
</row>
<row>
<column name="Notes">Work as per schedule, except not connected to
supply to test.
2 lamps fitted and 3 spare.
Megger >700MOhm.</column>
<column name="MaintLogID1">BRMR35029819</column>
</row>
<row>
<column name="Notes">Checked all wiring and found to be in a good
condition.
Checked all filters in the tumble driers both crew and officers all cleaned
out.
Checked operation of all tumble driers and found to operate correctly also
stopping when door opened.
Checked the operation of the roller iron and found to operate correctly.
Checked the earth leakage trips on all relevant machines and found to be
fully functional.
No defects to report.
Still waiting for spiner spare parts</column>
<column name="MaintLogID1">BRMR35029820</column>
</row>
<row>
<column name="Notes">Starter panel checked and cleaned.
Cable connection check and tied.
Check thermal protection settings and found ok.
Megger motor >500MOhm.
OIL SAMPLES
Duty Nav Call (Master's Cabin), All Nav call and 3 minute timer
checked. All okay</column>
<column name="MaintLogID1">BRMR35029900</column>
</row>
<row>
<column name="Notes">This PM is completed by the Engine room crew
as part of the saterday routines.</column>
<column name="MaintLogID1">BRMR35029901</column>
</row>
<row>
<column name="Notes">All machinery listed on PM, were rotated by
hand. First ensureing the stop button
was in the lock position.</column>
<column name="MaintLogID1">BRMR35029902</column>
</row>
<row>
<column name="Notes">Flushed with hot water.</column>
<column name="MaintLogID1">BRMR35029903</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029904</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029905</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029906</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029907</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029908</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029909</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029910</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029911</column>
</row>
<row>
<column name="Notes">All satisfactory</column>
<column name="MaintLogID1">BRMR35029912</column>
</row>
<row>
<column name="Notes">greased</column>
<column name="MaintLogID1">BRMR35029913</column>
</row>
<row>
<column name="Notes">greased</column>
<column name="MaintLogID1">BRMR35029914</column>
</row>
<row>
<column name="Notes">No defects reported.</column>
<column name="MaintLogID1">BRMR35029915</column>
</row>
<row>
<column name="Notes">Equipment checked and found to be in good
working order.</column>
<column name="MaintLogID1">BRMR35029916</column>
</row>
<row>
<column name="Notes">Motor re-assembeld. One silencer missing.
Tested and found to be working OK.</column>
<column name="MaintLogID1">BRMR35029917</column>
</row>
<row>
<column name="Notes">New accelerometers installed as per work
order.</column>
<column name="MaintLogID1">BRMR35029918</column>
</row>
<row>
<column name="Notes">PORT SIDE MOTOR:
While stowing port combination ladder after departure from Isle of Grain it
has been noted that motor is
not functioning normally. Motor stripped and one of the backerlite plates
found damaged and stuck insithe the rotor.
Plate erplaced and motor reassembled - tested and found woring OK.
</column>
<column name="MaintLogID1">BRMR35029919</column>
</row>
<row>
<column name="Notes">PORT SIDE MOTOR:
While stowing port combination ladder after departure from Isle of Grain it
has been noted that motor is
not functioning normally. Motor stripped and one of the backerlite plates
found damaged and stuck insithe the rotor.
Plate erplaced and motor reassembled - tested and found woring OK.
</column>
<column name="MaintLogID1">BRMR35029920</column>
</row>
<row>
<column name="Notes">Checked after departure from Isle Of Grain.
Inspection completed on 19/11/07 - all well greased and moving freely.
Constant problems with water accumulating in the airline. Oil is being
displaced by water after one use and since the
oiler is being fed from the bottom of the oil cup there's no
sufficient lubrication in the line.
Correct oil level in gearbox and in line oiler unit topped up.
</column>
<column name="MaintLogID1">BRMR35029921</column>
</row>
<row>
<column name="Notes">Fire-eye removed and cleaned. Shutter found to
be sticking during operation. Shutter mechanism
cleaned.</column>
<column name="MaintLogID1">BRMR35029922</column>
</row>
<row>
<column name="Notes">Fire-eye removed and cleaned. Shutter found to
be sticking during operation. Shutter mechanism
cleaned.</column>
<column name="MaintLogID1">BRMR35029923</column>
</row>
<row>
<column name="Notes">Mechanical seal replaced. only carbon ring on
the non drive end of the seal was not replaced due to no spare. This ring
was
found to be in good condition. Pump was run on test and no leaks evident.
The lip seal on the shaft was badly damaged but
Again there was no spare. One is on order now.</column>
<column name="MaintLogID1">BRMR35029924</column>
</row>
<row>
<column name="Notes">All strum boxes cleaned.</column>
<column name="MaintLogID1">BRMR35029925</column>
</row>
<row>
<column name="Notes">Belts and spray valve all OK.</column>
<column name="MaintLogID1">BRMR35029926</column>
</row>
<row>
<column name="Notes">Belts and spray valve all OK.</column>
<column name="MaintLogID1">BRMR35029927</column>
</row>
<row>
<column name="Notes">Not done due to bad weather</column>
<column name="MaintLogID1">BRMR35029928</column>
</row>
<row>
<column name="Notes">Not done due to bad weather</column>
<column name="MaintLogID1">BRMR35029929</column>
</row>
<row>
<column name="Notes">Not done due to bad weather</column>
<column name="MaintLogID1">BRMR35029930</column>
</row>
<row>
<column name="Notes">The ppm monitor was tested, as per the
instructions on the PM. There was no need for
recalibrationof the unit. The desiccator does not need replacing as
yet.</column>
<column name="MaintLogID1">BRMR35029931</column>
</row>
<row>
<column name="Notes">The stop button on the Fire p/p was locked in
the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.</column>
<column name="MaintLogID1">BRMR35029932</column>
</row>
<row>
<column name="Notes">The stop button on the Fire p/p was locked in
the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.</column>
<column name="MaintLogID1">BRMR35029933</column>
</row>
<row>
<column name="Notes">The stop button on the S/G water spray p/p
was locked in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.</column>
<column name="MaintLogID1">BRMR35029934</column>
</row>
<row>
<column name="Notes">The stop button on the no3 ballast p/p was
locked in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The water tank was then topped up with water.
The machinery was then returned to standby condition.</column>
<column name="MaintLogID1">BRMR35029935</column>
</row>
<row>
<column name="Notes">The stop button on the no2 G/S p/p was locked
in the stop position.
The priming pump was then rotated by hand,and the piston actuator was free
to move.
The machinery was then returned to standby condition.</column>
<column name="MaintLogID1">BRMR35029936</column>
</row>
<row>
<column name="Notes">Operated all shipside v/v's that are not
is regular use. All v/v spindles were well lubricated and
free to move.</column>
<column name="MaintLogID1">BRMR35029937</column>
</row>
<row>
<column name="Notes">Not done due to bad weather.</column>
<column name="MaintLogID1">BRMR35029938</column>
</row>
<row>
<column name="Notes">Not done due to bad weather.</column>
<column name="MaintLogID1">BRMR35029939</column>
</row>
<row>
<column name="Notes">Alarm OK.</column>
<column name="MaintLogID1">BRMR35029940</column>
</row>
<row>
<column name="Notes">Compressors changed over No 1 Now in
use.</column>
<column name="MaintLogID1">BRMR35029941</column>
</row>
<row>
<column name="Notes">Compressors changed over No 1 Now in
use.</column>
<column name="MaintLogID1">BRMR35029942</column>
</row>
<row>
<column name="Notes">2 bags Bio aug dosed to sewage treatment
plant.</column>
<column name="MaintLogID1">BRMR35029943</column>
</row>
<row>
<column name="Notes">Filter cleaned as required.</column>
<column name="MaintLogID1">BRMR35029944</column>
</row>
<row>
<column name="Notes">Out of service, awaiting L.O temp
probe.</column>
<column name="MaintLogID1">BRMR35029945</column>
</row>
<row>
<column name="Notes">Compressors changed over No 3 Now in
use.</column>
<column name="MaintLogID1">BRMR35029946</column>
</row>
<row>
<column name="Notes">Compressors changed over No 3 Now in
use.</column>
<column name="MaintLogID1">BRMR35029947</column>
</row>
<row>
<column name="Notes">Dryers changed over No 2 Now in use.</column>
<column name="MaintLogID1">BRMR35029948</column>
</row>
<row>
<column name="Notes">Dryers changed over No 2 Now in use.</column>
<column name="MaintLogID1">BRMR35029949</column>
</row>
<row>
<column name="Notes">All alarms and trips were tested on the
Incinerator and were successful.
All set points returned to normal. Incinerator ready for use.
</column>
<column name="MaintLogID1">BRMR35029950</column>
</row>
<row>
<column name="Notes">Both compressors replaced with new units.
System checked for leaks - none found.
System vacuum purged.
Run on test satisfactorily.</column>
<column name="MaintLogID1">BRMR35029951</column>
</row>
<row>
<column name="Notes">Checked emergency lights.Switched off relvent
breaker for 30 min.
All battery power lights worked satisfactory. </column>
<column name="MaintLogID1">BRMR35029952</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Found all in good condition.
All connections tight and secure.
No hot spots and signs of overheating.</column>
<column name="MaintLogID1">BRMR35029953</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Found all in good condition.
All connections tight and secure.
No hot spots and signs of overheating.</column>
<column name="MaintLogID1">BRMR35029954</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Found all in good condition.
All connections tight and secure.
No hot spots and signs of overheating.</column>
<column name="MaintLogID1">BRMR35029955</column>
</row>
<row>
<column name="Notes">Completed as per PM.
Found all in good condition.
All connections tight and secure.
No hot spots and signs of overheating.</column>
<column name="MaintLogID1">BRMR35029956</column>
</row>
<row>
<column name="Notes">Bilges inspected and level alarm tested - all
working OK.</column>
<column name="MaintLogID1">BRMR35029957</column>
</row>
<row>
<column name="Notes">Bilges inspected and level alarm tested - all
working OK.</column>
<column name="MaintLogID1">BRMR35029958</column>
</row>
<row>
<column name="Notes">Hoses tested and working OK</column>
<column name="MaintLogID1">BRMR35029959</column>
</row>
<row>
<column name="Notes">All isolating valves operated and greased as
required - no defects reported</column>
<column name="MaintLogID1">BRMR35029960</column>
</row>
<row>
<column name="Notes">Hoses tested as per rota - all working
OK</column>
<column name="MaintLogID1">BRMR35029961</column>
</row>
<row>
<column name="Notes">Sample landed ashore for analysis.</column>
<column name="MaintLogID1">BRMR35029962</column>
</row>
<row>
<column name="Notes">All strainers cleaned as per list.
All gaskets and fastenings found to be in good condition.
Central cooling anodes found to be badly wasted, due for replacement in dry
dock, no spares on board old ones refitted.</column>
<column name="MaintLogID1">BRMR35029963</column>
</row>
<row>
<column name="Notes">New probe fitted.
Tested and found satisfactory.</column>
<column name="MaintLogID1">BRMR35029964</column>
</row>
<row>
<column name="Notes">No 2 pump run upto speed all
satisfactory.</column>
<column name="MaintLogID1">BRMR35029965</column>
</row>
<row>
<column name="Notes">Starter panel checked and cleaned.
Cable connection check and tied.
Check thermal protection settings and found ok.
Megger motor >900MOhm.
All in good working condition.
</column>
<column name="MaintLogID1">BRMR35029966</column>
</row>
<row>
<column name="Notes">Starter panel checked and cleaned.
Cable connection check and tied.
Check thermal protection settings and found ok.
All in good working condition.
Megger motor >999MOhm.
Heaters:
1,2,3,4,5>=600MOhm
6,7 40 MOhm
8>600MOhm</column>
<column name="MaintLogID1">BRMR35029967</column>
</row>
<row>
<column name="Notes">No 2 pump run for a short time. All pressures
and oil satisfactory.</column>
<column name="MaintLogID1">BRMR35029968</column>
</row>
<row>
<column name="Notes">Pump started using local start, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35029969</column>
</row>
<row>
<column name="Notes">Started using battery, all
satisfactory.</column>
<column name="MaintLogID1">BRMR35029970</column>
</row>
<row>
<column name="Notes">All pressures and temps satisfactory.</column>
<column name="MaintLogID1">BRMR35029971</column>
</row>
<row>
<column name="Notes">All sets and cylinder pressures correct.
Comp run to fill up 2 cylinders all satisfactory.</column>
<column name="MaintLogID1">BRMR35029972</column>
</row>
<row>
<column name="Notes">Teflon spring cap on distillate regulating
valve found to be holed which released the spring tension.
New cap fitted from old spare regulating valve and proved satisfactory.
Needle valve fitted to vacuum breaker to allow precise control of shell
vacuum in cold waters to give better pressure control.
Evap run up and tested and all satisfactory.</column>
<column name="MaintLogID1">BRMR35029973</column>
</row>
<row>
<column name="Notes">All priming pump and control mechanisims
stripped down and inspected. All found to be free and in good condition.
All greased, new gaskets made and refitted to pumps.
Run on test and found to be running correctly.</column>
<column name="MaintLogID1">BRMR35029974</column>
</row>
<row>
<column name="Notes">Coupling drained and flushed through with new
oil.
Filled to correct level.</column>
<column name="MaintLogID1">BRMR35029975</column>
</row>
<row>
<column name="Notes">Oil drained and flushed with new oil.
New oil filled to correct level.</column>
<column name="MaintLogID1">BRMR35029976</column>
</row>
<row>
<column name="Notes">Governor oil changed as per P.M and
manual.</column>
<column name="MaintLogID1">BRMR35029977</column>
</row>
<row>
<column name="Notes">Both filters cleaned.
No particles found in either filter and both found to be clean when taken
out.</column>
<column name="MaintLogID1">BRMR35029978</column>
</row>
<row>
<column name="Notes">Completed as part of 12 monthly P.M for
checking all priming pumps.
Pump stripped down and found to be in good condition. All bearings and
linkages free to move with no signs of wear.
Pump run on test and all satisfactory.</column>
<column name="MaintLogID1">BRMR35029979</column>
</row>
<row>
<column name="Notes">Completed as part of 12 monthly inspection.
Bearings and linkages all in good order with no signs of wear.
Pump/pump casing found to be in good condition.
Run on test and all satisfactory. </column>
<column name="MaintLogID1">BRMR35029980</column>
</row>
<row>
<column name="Notes">All alarms and trips tested as per P.M and
found to be working correctly.</column>
<column name="MaintLogID1">BRMR35029981</column>
</row>
<row>
<column name="Notes">Valve overhauled during last dry docking.
Once these items were replaced the Flame eye functioned correctly</column>
<column name="MaintLogID1">BRMR35029983</column>
</row>
<row>
<column name="Notes">Feed back made good.</column>
<column name="MaintLogID1">BRMR35029984</column>
</row>
<row>
<column name="Notes">
Test procedure: Remove covers from the Omicron units, locally at each tank
liquid dome and lift test lever.
Vapour Header Vent Control Tank Protection Open 23kpa Close 21kpa
</column>
<column name="MaintLogID1">BRMR35029985</column>
</row>
<row>
<column name="Notes">All of the trips and alarms for No.2 N2 plant
have been tested.
All alarms and trips activated at the correct values. There are no defects
to report.</column>
<column name="MaintLogID1">BRMR35029986</column>
</row>
<row>
<column name="Notes">Port ESD valves operated on the 12th nov.
All of the valve blocks are badly corroded. It is on the c/o defects lists
to chip and paint these blocks.
CL042 has got a snapped off hydraulic isolation needle valve spindle. I
have set up a defect for this and will repair
it in the near future. The defect No. is MER/07/04417.
This valve was also found not to have any o-ring or gaskets for the manual
operation covers. New ones have been fitted.
</column>
<column name="MaintLogID1">BRMR35029987</column>
</row>
<row>
<column name="Notes">Dry powder unit number 3. ( fwd unit )
The charge bottle number 5 has lost its charge. Currently at 4Mpa.
A new bottle is currently being ordered and will get changed when it
arrives onboard.
Both of the manifod dry powder units where found to be good condition the
only defect on them is that the
local release boxes where very stiff to open. The fitter has made up new
hinges and they are now in good condition.
The local instructions for the stbd unit manifold unit are starting to
fade. This has been passed onto the mate for the bosan
to repaint.
All of the local hose reels, valves and nozzles where free to operate.
Fwd station
Bottle
1 - 10.3Mpa
2 - 10.5Mpa
3 - 10.2Mpa
4 - 10.0Mpa
5 - 4.0Mpa
Port station
Bottle
1 - 10.1Mpa
2 - 10.4Mpa
3 - 10.2Mpa
4 - 10.1Mpa
5 - 10.2Mpa
6 - 10.1Mpa
7 - 10.1Mpa
8 - 10.2Mpa
Stbd station
Bottle
1 - 10.1Mpa
2 - 10.4Mpa
3 - 10.4Mpa
4 - 10.2Mpa
5 - 10.6Mpa
6 - 10.3Mpa
7 - 10.5Mpa
8 - 10.2Mpa
</column>
<column name="MaintLogID1">BRMR35029988</column>
</row>
<row>
<column name="Notes">Port manifold valve operated on the 12th Nov.
Like the liquid ESD valves the hydraulic blocks are in bad condition. These
are on the list to
being chipped and painted</column>
<column name="MaintLogID1">BRMR35029989</column>
</row>
<row>
<column name="Notes">We have been having been having problems the
vane feed back during certain loads.
I have increased the oil pressure approx 20kpa, so that is in line with the
other units.
We have also fitted a new feed back pot. This has been zero'd and
spanned.
The loads where we have been experiencing problems are between 30 >
35Hz's and about -1degree vane position.
</column>
<column name="MaintLogID1">BRMR35029990</column>
</row>
<row>
<column name="Notes">Both bellows are in good condition.
The fan is free to turn and rotates without any vibs or noise.
The motor holding bolts where all tightened about 1/2 turn each.