SPECTRUM Downhole Monitoring System
SPECTRUM Downhole Monitoring System
SERIES
400
alkhorayefpetroleum.com
ESP Downhole Monitoring System
APPLICATIONS
Measured parameter Monitoring uses ESP protection
Intake pressure • Free Gas breakout • Closed loop response from VSD to
• Well Productivity maintain higher FLOP
• Trip/Alarm to protect against Pump Off
condition
Intake temperature • Changing fluid properties • Protect from increasing gauge
• Indication of stress on insulation temperatures
• Diagnose recirculation
Motor oil/winding temperature • Calculate operating temperature rise • Protect from motor overheating
• Indication of fluid property changes
• Indication of system electrical imbalance
• Diagnose low flow, overloading,
mechanical wear, high friction losses in
ESP system
Discharge pressure • Evidence of pump operating point • Protect against pump operating out of
• Protect from dead heading, incorrect range
rotation • Protect from producing against closed
valve
Vibration (Vx, Vy, Vz) • Indication of pump bend, mechanical • Set frequency avoidance bands
wear, abrasives, gas slugging
• Evidence of resonant frequency
Current leakage • Indication of insulation degradation • Trend over time, increasing value
across ESP system indicative of impending ground fault
APPLICATION SPECIFICATIONS
Measurement Range Resolution Accuracy
Intake pressure, psi (kPa) 0 - 5,800 (0 - 39,989) 0.1 0.2%
Discharge pressure, psi (kPa) 0 - 5,800 (0 - 39,989) 0.1 0.2%
Intake temperature, °F (°C) 32 - 302 (0 -150) 0.1 (0.1) 0.01%
Motor oil or winding temperature, °F (°C) 32 - 482 (0 -250) 0.1 (0.1) 0.01%
Vibration, (Vx, Vz) g 0 - 30 0.01 0.1%
Current leakage, mA 0 - 25 0.001 0.04%
Always producing