ESP Downhole Monitoring System

Optimize ESP performance to maximize APPLICATIONS


production
The SPECTRUM Downhole Monitoring System is an High workover cost ESP installations
Electrical Submersible Pump (ESP) gauge that provides Offshore/Remote ESP installations
fast, reliable and continuous data on reservoir and pump ESP installations requiring reservoir
performance. information
ESP installations requiring
Dynamic well conditions require fine-tuning of the ESP
to ensure the pump remains at the best efficiency point, optimization/troubleshooting
realizing power savings, longer run life and ultimately
reduced operational expenditure, in terms of both BENEFITS
workover and deferred production costs.
Long term trending of equipment and
Flexible configuration options reservoir performance
Installed at the base of the ESP, directly or via a motor
adapter, all sensors are housed in a 13 chrome stainless
Optimize ESP
steel body and rated to 302°F (150°C) and 5,800 PSI. Optimize reservoir recovery
Prevent dead heading (against
Alarms can be set for each measured parameter and are closed chokes/valves)
configurable based on application. Prevent ESP motor overheating
The SPECTRUM ESP gauge is compatible with other Monitoring of insulation degradation
monitoring and control technologies and is SCADA ready
with an industry standard Modbus protocol terminal
(RS232 and RS485).
FEATURES
Rigorously tested at 165°C, 5,800PSI
13 chrome metallurgy
Compatible with existing SCADA
Modbus Maps
Configurable data update rate
Calibrated during manufacturing
5KV high voltage interface
Flexible surface package options
2GB data logger

SERIES

400

alkhorayefpetroleum.com
ESP Downhole Monitoring System

APPLICATIONS
Measured parameter Monitoring uses ESP protection
Intake pressure • Free Gas breakout • Closed loop response from VSD to
• Well Productivity maintain higher FLOP
• Trip/Alarm to protect against Pump Off
condition
Intake temperature • Changing fluid properties • Protect from increasing gauge
• Indication of stress on insulation temperatures
• Diagnose recirculation
Motor oil/winding temperature • Calculate operating temperature rise • Protect from motor overheating
• Indication of fluid property changes
• Indication of system electrical imbalance
• Diagnose low flow, overloading,
mechanical wear, high friction losses in
ESP system
Discharge pressure • Evidence of pump operating point • Protect against pump operating out of
• Protect from dead heading, incorrect range
rotation • Protect from producing against closed
valve
Vibration (Vx, Vy, Vz) • Indication of pump bend, mechanical • Set frequency avoidance bands
wear, abrasives, gas slugging
• Evidence of resonant frequency
Current leakage • Indication of insulation degradation • Trend over time, increasing value
across ESP system indicative of impending ground fault

APPLICATION SPECIFICATIONS
Measurement Range Resolution Accuracy
Intake pressure, psi (kPa) 0 - 5,800 (0 - 39,989) 0.1 0.2%
Discharge pressure, psi (kPa) 0 - 5,800 (0 - 39,989) 0.1 0.2%
Intake temperature, °F (°C) 32 - 302 (0 -150) 0.1 (0.1) 0.01%
Motor oil or winding temperature, °F (°C) 32 - 482 (0 -250) 0.1 (0.1) 0.01%
Vibration, (Vx, Vz) g 0 - 30 0.01 0.1%
Current leakage, mA 0 - 25 0.001 0.04%

SPECTRUM DOWNHOLE MONITORING SYSTEM SPECIFICATIONS


Length, in (cm) 20.00 (50.80)
OD, in (cm) 4.50 (11.43)
Weight, lbs (kg) 50.70 (23.0)
Max. environmental pressure, psi (kPa) 6,500 (44,815)
Rated temperature, °F (°C) 302 (150)
Tested insulation rating, V DC Reverse polarity to 5,000V DC for 10 seconds
Material 13 chrome stainless steel
Bottom connection, in (cm) 2-3/8 (6.033) 8RND EUE box
Maximum load, lbs (kg) 2,645.5 (1,200)

Always producing
alkhorayefpetroleum.com