Professional Documents
Culture Documents
IST-100-1 PROTOCOL MANUAL Rev-28871
IST-100-1 PROTOCOL MANUAL Rev-28871
IST-100-1 PROTOCOL MANUAL Rev-28871
www.qualitrolcorp.com
Legal
Information in this document is subject to change without notice. This document is provided to purchasers of Qualitrol
products for use in the installation, operation and servicing of such products. No other use, nor any reproduction,
distribution or the making of any derivatives of this document is authorized, without the express prior written permission of
Qualitrol.
Qualitrol endeavors to ensure the accuracy and quality of its published materials; however, no warranty, expressed or
implied, is provided. Qualitrol disclaims any responsibility or liability for any direct or indirect damages resulting from the
use of the information in this manual or products described in it. Mention of any product or brand does not constitute an
endorsement by Qualitrol of that product or brand.
This document was originally composed in English and was subsequently translated into other languages. The fidelity of
subsequent translations cannot be guaranteed. In case of conflict between the English version and another language
version, the English version takes precedence.
©2010 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice.
®
All trademarks are properties of their respective companies, as noted herein. IST-104-1.
www.qualitrolcorp.com
Protocol Manual
Contents
Hardware Instructions.................................................................................... 1
OVERVIEW ................................................................................................................ 1
Communications for the Qualitrol 509ITM Series Transformer Monitor ............................ 1
General .............................................................................................................................. 1
About Qualitrol ................................................................................................................... 2
DNP 3.0 Communications .............................................................................. 3
Introduction .............................................................................................................. 3
DNP V3.0 Device Profile ........................................................................................... 3
DNP V3.0 Implementation Table.............................................................................. 6
DNP V3.0 Point List ................................................................................................ 14
Binary Input Points ............................................................................................................. 14
Binary Output Status Points ............................................................................................ 16
Counters .......................................................................................................................... 17
Analog Inputs .................................................................................................................. 18
Analog Output Status Points ........................................................................................... 29
Octet Strings .................................................................................................................... 32
Time and Date .................................................................................................................32
Modbus Protocol .......................................................................................... 33
General .................................................................................................................... 33
Function Codes Supported ................................................................................... 33
Modbus Register Map ............................................................................................ 33
Binary Parameters ........................................................................................................... 33
Binary Parameters ........................................................................................................... 34
Analog Parameters .......................................................................................................... 35
Analog Parameters .......................................................................................................... 46
String Parameters ........................................................................................................... 49
Analog Parameters .......................................................................................................... 52
Analog Parameters .......................................................................................................... 53
String Parameters ........................................................................................................... 54
Analog Parameters .......................................................................................................... 62
String Parameters ........................................................................................................... 62
www.qualitrolcorp.com
Protocol Manual
www.qualitrolcorp.com
Protocol Manual
Hardware Instructions
OVERVIEW
Communications for the Qualitrol 509ITM Series
Transformer Monitor
General
The 509ITM comes equipped with digital communication capabilities and a four-wire RS485 port
comes on the rear of the device. Optional ports; an asynchronous serial fiber optic port and/or an
Ethernet port can be ordered. (See the 509ITM configuration form when ordering). The hardware
wiring and configuring the software for the ports is explained in the 509ITM Hardware/Software
Manual IST-099-1.
The 509ITM must be configured for the proper communication protocol for each active port using the
Qualitrol ITM Manager Software package supplied with the unit (or downloaded from the Qualitrol
Web Site (www.qualitrolcorp.com). Using the software package the user can configure the 509ITM
for the appropriate protocol, baud rates, data bits, etc. for their system requirements (see the
communication window below). Once the correct parameters have been entered and loaded into the
509ITM the unit must have power cycled before these new values will take affect.
1 www.qualitrolcorp.com
Protocol Manual
About Qualitrol
Qualitrol has been a leader in supplying pressure, liquid level and temperature controls since 1945.
As an ISO 9001 System-certified company, we are committed to providing quality and reliability, both
in our products and in our service.
2 www.qualitrolcorp.com
Protocol Manual
DNP V3.0
DEVICE PROFILE DOCUMENT
Vendor Name: Qualitrol
Device Name: 509ITM
Highest DNP Level Supported: Device Function:
For Requests:
For Responses:
Level 3
Level 3
Master
Slave
3 www.qualitrolcorp.com
Protocol Manual
DNP V3.0
DEVICE PROFILE DOCUMENT
Notable objects, functions, and/or qualifiers supported in addition to the Highest DNP Levels
Supported (the complete list is described in the attached table):
For static (non-change-event) object requests, request qualifier codes 07 and 08 (limited quantity), and 17 and 28 (index) are
supported. Static object requests sent with qualifiers 07, or 08, will be responded with qualifiers 00 or 01.
16-bit, 32-bit and Floating Point Analog Change Events with Time may be requested.
Analog Input Deadbands, Object 34, variations 1 through 3, are supported.
Floating Point Analog Output Status and Output Block Objects 40 and 41 are supported.
Sequential file transfer, Object 70, variations 2 through 8, are supported.
Octet String and String Event Objects 110 and 111 are supported.
Virtual Terminal Output and Event Objects 112 and 113 are supported.
Device Attribute Object 0 is supported.
Data Set Objects 85-88 are supported.
Output Event Objects 11, 13, 42 and 43 are supported.
Activate Configuration
Secure Authentication
Maximum Data Link Frame Size (octets): Maximum Application Fragment Size (octets):
None None
Fixed Configurable
Configurable from 0 to 65535
Requires Data Link Layer Confirmation:
Never
Always
Sometimes
Configurable as: Never, Only for multi-frame messages, or Always
Requires Application Layer Confirmation:
Never
Always
When reporting Event Data (Slave devices only)
When sending multi-fragment responses (Slave devices only)
Sometimes
Configurable as: “Only when reporting event data”, or “When reporting event data or
multi-fragment messages.”
4 www.qualitrolcorp.com
Protocol Manual
DNP V3.0
DEVICE PROFILE DOCUMENT
Timeouts while waiting for:
Never Never
Only time-tagged Binary Input Change With Time
Only non-time-tagged Binary Input Change With Relative Time
Configurable to send one or the Configurable
other
5 www.qualitrolcorp.com
Protocol Manual
DNP V3.0
DEVICE PROFILE DOCUMENT
Sends Unsolicited Responses: Sends Static Data in Unsolicited Responses:
Never Never
Configurable When Device Restarts
Only certain objects
Sometimes (attach explanation)
When Status Flags Change
ENABLE/DISABLE UNSOLICITED No other options are permitted.
Function codes supported
Default Counter Object/Variation: Counters Roll Over at:
6 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
0 1-253 Device Attribute Specific 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
2 (write) 00, 01 (start-stop)
0 254 Device Attribute - Non-Specific All 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
Attributes Request 06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
0 255 Device Attribute – List of Attribute 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
Variations 06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
1 0 Binary Input – Any Variation 1 (read) 00, 01 (start-stop)
22 (assign 06 (no range, or all)
class) 07, 08 (limited qty)
17, 27, 28 (index)
1 1 Binary Input 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
1 2 Binary Input with Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
2 0 Binary Input Change – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
2 1 Binary Input Change without Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
2 2 Binary Input Change with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
2 3 Binary Input Change with Relative Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
(default – 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
3 0 Double Bit Input – Any Variation 1 (read) 00, 01 (start-stop)
22 (assign 06 (no range, or all)
class) 07, 08 (limited qty)
17, 27, 28 (index)
3 1 Double Bit Input 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 1)
07, 08 (limited qty)
17, 27, 28 (index)
3 2 Double Bit Input with Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
4 0 Double Bit Input Change – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
4 1 Double Bit Input Change without Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
07, 08 (limited qty) 130 (unsol. resp)
4 2 Double Bit Input Change with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
07, 08 (limited qty) 130 (unsol. resp)
4 3 Double Bit Input Change with Relative 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
(default – Time 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
10 0 Binary Output – Any Variation 1 (read) 00, 01 (start-stop)
22 (assign 06 (no range, or all)
class) 07, 08 (limited qty)
17, 27, 28 (index)
7 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
10 1 Binary Output 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
1 (write 00, 01 (start-stop)
10 2 Binary Output Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
11 0 Binary Output Change – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
11 1 Binary Output Change without Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
(default – 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
11 2 Binary Output Change with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
07, 08 (limited qty) 130 (unsol. resp)
12 0 Control Relay Output Block 22 (assign 00, 01 (start-stop)
class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
12 1 Control Relay Output Block 3 (select) 17, 28 (index) 129 (response) echo of request
4 (operate)
5 (direct op)
6 (dir. op, noack)
12 2 Pattern Control Block 3 (select) 7 (limited quantity) 129 (response) echo of request
4 (operate)
5 (direct op)
6 (dir. op, noack)
12 3 Pattern Mask 3 (select) 00, 01 (start- 129 (response) echo of request
4 (operate) stop)
5 (direct op)
6 (dir. op, noack)
13 0 Binary Output Command Event – Any 1 (read) 06 (no range, or all)
Variation 07, 08 (limited qty)
13 1 Binary Output Command Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
Time 07, 08 (limited qty) 130 (unsol. resp)
13 2 Binary Output Command Event with 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index )
Time 07, 08 (limited qty) 130 (unsol. resp)
20 0 Binary Counter – Any Variation 1 (read) 00, 01 (start-stop)
22 (assign class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
8 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
21 0 Frozen Counter – Any Variation 1 (read) 00, 01 (start-stop)
22 (assign class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
21 1 32-Bit Frozen Counter (with Flag) 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
21 2 16-Bit Frozen Counter (with Flag) 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
21 5 32-Bit Frozen Counter with Time Of 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-
Freeze 06 (no range, or all) stop)
07, 08 (limited qty) 17, 28 (index –
17, 27, 28 (index) see note 1)
21 6 16-Bit Frozen Counter with Time Of 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-
Freeze 06 (no range, or all) stop)
07, 08 (limited qty) 17, 28 (index –
17, 27, 28 (index) see note 1)
21 9 32-Bit Frozen Counter without Flag 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
21 10 16-Bit Frozen Counter without Flag 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
22 0 Counter Change Event – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
22 1 32-Bit Counter Change Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
(default – Time 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
22 2 16-Bit Counter Change Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Time 07, 08 (limited qty) 130 (unsol. resp)
22 5 32-Bit Counter Change Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
22 6 16-Bit Counter Change Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
23 0 Frozen Counter Event (Variation 0 is 1 (read) 06 (no range, or all)
used to request default variation) 07, 08 (limited qty)
23 1 32-Bit Frozen Counter Event 1 (read) 06 (no range, or all) 129 (response) 17,28 (index)
(default – 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
23 2 16-Bit Frozen Counter Event 1 (read) 06 (no range, or all) 129 (response) 17,28 (index)
07, 08 (limited qty) 130 (unsol. resp)
23 5 32-Bit Frozen Counter Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
23 6 16-Bit Frozen Counter Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
30 0 Analog Input - Any Variation 1 (read) 00, 01 (start-stop)
22 (assign class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
30 1 32-Bit Analog Input 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
30 2 16-Bit Analog Input 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
9 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
30 3 32-Bit Analog Input without Flag 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
30 4 16-Bit Analog Input without Flag 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
30 5 short floating point 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
30 6 long floating point 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 1)
17, 27, 28 (index)
32 0 Analog Change Event – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
32 1 32-Bit Analog Change Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
(default – Time 07, 08 (limited qty) 130 (unsol. resp)
see note 1)
32 2 16-Bit Analog Change Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Time 07, 08 (limited qty) 130 (unsol. resp)
32 3 32-Bit Analog Change Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
32 4 16-Bit Analog Change Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
32 5 short floating point Analog Change 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Event without Time 07, 08 (limited qty) 130 (unsol. resp)
32 6 long floating point Analog Change Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
without Time 07, 08 (limited qty) 130 (unsol. resp)
32 7 short floating point Analog Change 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Event with Time 07, 08 (limited qty) 130 (unsol. resp)
32 8 long floating point Analog Change Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
with Time 07, 08 (limited qty) 130 (unsol. resp)
34 0 Analog Input Deadband (Variation 0 is 1 (read) 00, 01 (start-stop)
used to request default variation) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
34 1 16 bit Analog Input Deadband 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
2 00, 01 (start-stop)
(write) 07, 08 (limited qty)
17, 27, 28 (index)
34 2 32 bit Analog Input Deadband 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1) see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
2 00, 01 (start-stop)
(write) 07, 08 (limited qty)
17, 27, 28 (index)
34 3 Short Floating Point Analog Input 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
Deadband 06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
2 00, 01 (start-stop)
(write) 07, 08 (limited qty)
17, 27, 28 (index)
40 0 Analog Output Status 1 (read) 00, 01 (start-stop)
22 (assign 06 (no range, or all)
class) 07, 08 (limited qty)
17, 27, 28 (index)
10 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
40 1 32-Bit Analog Output Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
40 2 16-Bit Analog Output Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(default – 06 (no range, or all) 17, 28 (index –
see note 1 see note 2)
07, 08 (limited qty)
17, 27, 28 (index)
40 3 short floating point Analog Output Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
40 4 long floating point Analog Output Status 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index)
41 0 Analog Output Block 22 (assign 00, 01 (start-stop)
class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index)
41 1 32-Bit Analog Output Block 3 (select) 17, 28 (index) 129 (response) echo of request
4 (operate) 27 (index)
5 (direct op)
6 (dir. op, noack)
41 2 16-Bit Analog Output Block 3 (select) 17, 28 (index) 129 (response) echo of request
4 (operate) 27 (index)
5 (direct op)
6 (dir. op, noack)
41 3 short floating point Analog Output Block 3 (select) 17, 27, 28 (index) 129 (response) echo of request
4 (operate)
5 (direct op)
6 (dir. op, noack)
41 4 long floating point Analog Output Block 3 (select) 17, 27, 28 (index) 129 (response) echo of request
4 (operate)
5 (direct op)
6 (dir. op, noack)
42 0 Analog Output Event – Any Variation 1 (read) 06 (no range, or all)
07, 08 (limited qty)
42 1 32-Bit Analog Output Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Time 07, 08 (limited qty) 130 (unsol. resp)
42 2 16-Bit Analog Output Event without 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
(default – Time 07, 08 (limited qty) 130 (unsol. resp)
see note 1
42 3 32-Bit Analog Output Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
42 4 16-Bit Analog Output Event with Time 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
07, 08 (limited qty) 130 (unsol. resp)
42 5 short floating point Analog Output Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
without Time 07, 08 (limited qty) 130 (unsol. resp)
42 6 long floating point Analog Output Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
without Time 07, 08 (limited qty) 130 (unsol. resp)
42 7 short floating point Analog Output Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
with Time 07, 08 (limited qty) 130 (unsol. resp)
42 8 long floating point Analog Output Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
with Time 07, 08 (limited qty) 130 (unsol. resp)
43 0 Analog Output Command Event – Any 1 (read) 06 (no range, or all)
Variation 07, 08 (limited qty)
43 1 32-Bit Analog Output Command Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
without Time 07, 08 (limited qty) 130 (unsol. resp)
43 2 16-Bit Analog Output Command Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
(default – without Time 07, 08 (limited qty) 130 (unsol. resp)
see note 1
43 3 32-Bit Analog Output Command Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
with Time 07, 08 (limited qty) 130 (unsol. resp)
11 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
43 4 16-Bit Analog Output Command Event 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
with Time 07, 08 (limited qty) 130 (unsol. resp)
43 5 short floating point Analog Output 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Command Event without Time 07, 08 (limited qty) 130 (unsol. resp)
43 6 long floating point Analog Output 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Command Event without Time 07, 08 (limited qty) 130 (unsol. resp)
43 7 short floating point Analog Output 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Command Event with Time 07, 08 (limited qty) 130 (unsol. resp)
43 8 long floating point Analog Output 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
Command Event with Time 07, 08 (limited qty) 130 (unsol. resp)
50 0 Time and Date
50 1 Time and Date 1 (read) 07, (limited qty = 1) 129 (response) 07 (limited qty = 1)
(default –
see note 1)
12 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
70 5 File Transfer 1 5b (free-format) 129 (response) 5B (free-format)
(read) 130 (unsol. resp)
2
(write)
2 (write) 00 (start-stop)
(see note 3) index=4 or 7
85 0 Data Set Prototype 1 00, 01 (start-stop)
(read) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index
85 1 Data Set Prototype 1 00, 01 (start-stop) 129 (response) 5B (free-format)
(read) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index
2 (write) 5b (free-format)
86 2 Data Set Descriptor – Characteristics 1 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
(read) 06 (no range, or all) 17, 28 (index –
07, 08 (limited qty) see note 2)
17, 27, 28 (index
86 3 Data Set Descriptor – Point Index 1 00, 01 (start-stop) 129 (response) 5B (free-format)
Attributes (read) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index
2 (write) 5b (free-format)
88 1 Data Set Event - Snapshot 1 06 (no range, or all) 129 (response) 5B (free-format)
(read) 07, 08 (limited qty) 130 (unsol. resp)
13 www.qualitrolcorp.com
Protocol Manual
REQUEST RESPONSE
OBJECT
(Library will parse) (Library will respond with)
Object Variation Function Qualifier Codes Function Qualifier Codes
Description
Number Number Codes (dec) (hex) Codes (dec) (hex)
110 string Octet String Object 1 (read) 00, 01 (start-stop) 129 (response) 00, 01 (start-stop)
length 22 (assign class) 06 (no range, or all)
07, 08 (limited qty)
17, 27, 28 (index
2 (write) 00, 01 (start-stop)
07, 08 (limited qty)
17, 27, 28 (index)
111 string Octet String Event Object 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
length 07, 08 (limited qty) 130 (unsol. resp)
112 string Virtual Terminal Output Block 2 (write) 00, 01 (start-stop)
length 07, 08 (limited qty)
17, 27, 28 (index)
113 string Virtual Terminal Event Data 1 (read) 06 (no range, or all) 129 (response) 17, 28 (index)
length 07, 08 (limited qty) 130 (unsol. resp)
120 1 Authentication Challenge 32 (auth 5b (free-format) 131 (challenge) 5b (free-format)
challenge) 132(unsol. challenge
120 2 Authentication Reply 33 (auth reply) 5b (free-format) 129 (response) 5b (free-format)
120 3 Authentication Aggressive Mode 5b (free-format) 131 (challenge) 5b (free-format)
Request 132(unsol. challenge
120 4 Authentication Session Key Status 1 (read) 5b (free-format)
Request
120 5 Authentication Session Key Status 129 (response) 5b (free-format)
120 6 Authentication Session Key Change 129 (response) 5b (free-format)
120 7 Authentication Error 34 (auth 5b (free-format) 129 (response) 5b (free-format)
challenge)
No Object (function code only) 13 (cold restart)
No Object (function code only) 14 (warm restart)
No Object (function code only) 23 (delay meas.)
No Object (function code only) 24
(record current
time)
Note 1: A Default variation refers to the variation responded when variation 0 is requested and/or in
class 0, 1, 2, or 3 scans. Default variations are configurable; however, default settings for the
configuration parameters are indicated in the table above.
Note 2: For static (non-change-event) objects, qualifiers 17 or 28 are only responded when a request
is sent with qualifiers 17 or 28, respectively. Otherwise, static object requests sent with qualifiers 00,
01, 06, 07, or 08, will be responded with qualifiers 00 or 01. (For change-event objects, qualifiers 17
or 28 are always responded.)
Note 3: Writes of Internal Indications are only supported for index 4 or 7 (Need Time IIN1-4 or
Restart IIN1-7)
14 www.qualitrolcorp.com
Protocol Manual
15 www.qualitrolcorp.com
Protocol Manual
16 www.qualitrolcorp.com
Protocol Manual
and it allows reporting of time-based information associated with controls, including any delays
before controls are actuated, and any durations if the controls are pulsed.
The default select/control buffer size is large enough to hold 10 of the largest select requests
possible.
Counters
The following table lists both Binary Counters (Object 20) and Frozen Counters (Object 21). When a
freeze function is performed on a Binary Counter point, the frozen value is available in the
corresponding Frozen Counter point. The default Binary Counter and Frozen Counter event buffer
sizes are set to 30.
17 www.qualitrolcorp.com
Protocol Manual
Analog Inputs
The following table lists Analog Inputs (Object 30). It is important to note that 16-bit and 32-bit
variations of Analog Inputs, Analog Output Control Blocks, and Analog Output Statuses are
transmitted through DNP as signed numbers.
The “Default Deadband,” and the “Default Change Event Assigned Class” columns are used to
represent the absolute amount by which the point must change before an analog change event will be
generated, and once generated in which class poll (1, 2, 3, or none) will the change event be
reported.
The default analog input event buffer size is set 30.
ALL MODULES BUT CT, WINDING TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
16 INPUT MODULE 1 PRESENT VALUE OR INPUT MODULE 1 PRESENT WINDING TEMP
17 INPUT MODULE 1 MINIMUM VALUE OR INPUT MODULE 1 MINIMUM WINDING TEMP
18 INPUT MODULE 1 MAXIMUM VALUE OR INPUT MODULE 1 MAXIMUM WINDING TEMP
19 0 OR INPUT MODULE 1 PRESENT CURRENT
20 0 OR INPUT MODULE 1 MAXIMUM CURRENT
21 INPUT MODULE 2 PRESENT VALUE OR INPUT MODULE 2 PRESENT WINDING TEMP
22 INPUT MODULE 2 MINIMUM VALUE OR INPUT MODULE 2 MINIMUM WINDING TEMP
23 INPUT MODULE 2 MAXIMUM VALUE OR INPUT MODULE 2 MAXIMUM WINDING TEMP
24 0 OR INPUT MODULE 2 PRESENT CURRENT
25 0 OR INPUT MODULE 2 MAXIMUM CURRENT
18 www.qualitrolcorp.com
Protocol Manual
19 www.qualitrolcorp.com
Protocol Manual
20 www.qualitrolcorp.com
Protocol Manual
21 www.qualitrolcorp.com
Protocol Manual
22 www.qualitrolcorp.com
Protocol Manual
23 www.qualitrolcorp.com
Protocol Manual
24 www.qualitrolcorp.com
Protocol Manual
25 www.qualitrolcorp.com
Protocol Manual
26 www.qualitrolcorp.com
Protocol Manual
27 www.qualitrolcorp.com
Protocol Manual
ALL MODULES BUT CT, WINDING TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
435 INPUT MODULE 9 PRESENT VALUE OR INPUT MODULE 9 PRESENT WINDING TEMP
436 INPUT MODULE 9 MINIMUM VALUE OR INPUT MODULE 9 MINIMUM WINDING TEMP
437 INPUT MODULE 9 MAXIMUM VALUE OR INPUT MODULE 9 MAXIMUM WINDING TEMP
438 0 OR INPUT MODULE 9 PRESENT CURRENT
439 0 OR INPUT MODULE 9 MAXIMUM CURRENT
440 INPUT MODULE 10 PRESENT VALUE OR INPUT MODULE 10 PRESENT WINDING TEMP
441 INPUT MODULE 10 MINIMUM VALUE OR INPUT MODULE 10 MINIMUM WINDING TEMP
442 INPUT MODULE 10 MAXIMUM VALUE OR INPUT MODULE 10 MAXIMUM WINDING TEMP
443 0 OR INPUT MODULE 10 PRESENT CURRENT
444 0 OR INPUT MODULE 10 MAXIMUM CURRENT
445 INPUT MODULE 11 PRESENT VALUE OR INPUT MODULE 11 PRESENT WINDING TEMP
446 INPUT MODULE 11 MINIMUM VALUE OR INPUT MODULE 11 MINIMUM WINDING TEMP
447 INPUT MODULE 11 MAXIMUM VALUE OR INPUT MODULE 11 MAXIMUM WINDING TEMP
448 0 OR INPUT MODULE 11 PRESENT CURRENT
449 0 OR INPUT MODULE 11 MAXIMUM CURRENT
450 INPUT MODULE 12 PRESENT VALUE OR INPUT MODULE 12 PRESENT WINDING TEMP
451 INPUT MODULE 12 MINIMUM VALUE OR INPUT MODULE 12 MINIMUM WINDING TEMP
452 INPUT MODULE 12 MAXIMUM VALUE OR INPUT MODULE 12 MAXIMUM WINDING TEMP
453 0 OR INPUT MODULE 12 PRESENT CURRENT
454 0 OR INPUT MODULE 12 MAXIMUM CURRENT
455 INPUT MODULE 13 PRESENT VALUE OR INPUT MODULE 13 PRESENT WINDING TEMP
456 INPUT MODULE 13 MINIMUM VALUE OR INPUT MODULE 13 MINIMUM WINDING TEMP
457 INPUT MODULE 13 MAXIMUM VALUE OR INPUT MODULE 13 MAXIMUM WINDING TEMP
458 0 OR INPUT MODULE 13 PRESENT CURRENT
459 0 OR INPUT MODULE 13 MAXIMUM CURRENT
460 INPUT MODULE 14 PRESENT VALUE OR INPUT MODULE 14 PRESENT WINDING TEMP
28 www.qualitrolcorp.com
Protocol Manual
29 www.qualitrolcorp.com
Protocol Manual
30 www.qualitrolcorp.com
Protocol Manual
31 www.qualitrolcorp.com
Protocol Manual
Octet Strings
The default string event buffer size is set to allow 10 events.
32 www.qualitrolcorp.com
Protocol Manual
Modbus Protocol
General
Qualitrol supports the Modbus RTU transmission mode in which the message is
placed by the transmitting device into a frame that has a known beginning and
ending point. This allows the 509ITM unit to begin at the start of the message, read
the address portion and determine which device is addressed and to know when the
message is completed. Partial messages can be detected and errors can be set as
a result.
To assist with the development of the Modbus communication for the user, there is a
web site, http://www.win-tech.com/html/demos.htm that offers evaluation software for
most applications.
33 www.qualitrolcorp.com
Protocol Manual
Binary Parameters
REG # VARIABLE R/W DESCRIPTION
50 RELAY 1 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
51 RELAY 2 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
52 RELAY 3 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
53 RELAY 4 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
54 RELAY 5 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
55 RELAY 6 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
56 RELAY 7 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
57 RELAY 8 ENABLED RD/WR 1 = ENABLED; 0 = DISABLED
58 INPUT MODULE MAX/MIN RESET RD/WR PULSE/RESET (1)
59 COOLING MONITOR MAX/MIN RESET RD/WR PULSE/RESET (1)
60 LATCHED RELAYS RESET RD/WR PULSE/RESET (1)
61 RELAY 1 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
62 RELAY 2 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
63 RELAY 3 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
64 RELAY 4 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
65 RELAY 5 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
66 RELAY 6 AUTO/MANUAL RD/WR 1 = MANUAL OPERATION; 0 = AUTOMATIC
34 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
Values in registers 100 thru 693 have been scaled according to their function to offer the greatest
possible resolution. If the description of the value has a (N) then there is no scaling. A (10X) means
the value has been multiplied by 10 and needs to be divided by 10 to read the actual value (e.g. if the
value in the 509ITM is 123.4 then it will be transmitted 1234). A (100X) means the value was
multiplied by 100 and needs to be divided by 100 to read the actual value (e.g. if the value in the
509ITM is 12.34 then it will be transmitted as 1234).
35 www.qualitrolcorp.com
Protocol Manual
ALL MODULES BUT CT, WINDING TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
116 INPUT MODULE 1 PRESENT VALUE READ OR INPUT MODULE 1 PRESENT WINDING TEMP (10X)
117 INPUT MODULE 1 MINIMUM VALUE READ OR INPUT MODULE 1 MINIMUM WINDING TEMP (10X)
118 INPUT MODULE 1 MAXIMUM VALUE READ OR INPUT MODULE 1 MAXIMUM WINDING TEMP (10X)
119 0 READ OR INPUT MODULE 1 PRESENT CURRENT (10X)
120 0 READ OR INPUT MODULE 1 MAXIMUM CURRENT (10X)
121 INPUT MODULE 2 PRESENT VALUE READ OR INPUT MODULE 2 PRESENT WINDING TEMP (10X)
122 INPUT MODULE 2 MINIMUM VALUE READ OR INPUT MODULE 2 MINIMUM WINDING TEMP (10X)
123 INPUT MODULE 2 MAXIMUM VALUE READ OR INPUT MODULE 2 MAXIMUM WINDING TEMP (10X)
124 0 READ OR INPUT MODULE 2 PRESENT CURRENT (10X)
125 0 READ OR INPUT MODULE 2 MAXIMUM CURRENT (10X)
126 INPUT MODULE 3 PRESENT VALUE READ OR INPUT MODULE 3 PRESENT WINDING TEMP (10X)
127 INPUT MODULE 3 MINIMUM VALUE READ OR INPUT MODULE 3 MINIMUM WINDING TEMP (10X)
128 INPUT MODULE 3 MAXIMUM VALUE READ OR INPUT MODULE 3 MAXIMUM WINDING TEMP (10X)
129 0 READ OR INPUT MODULE 3 PRESENT CURRENT (10X)
130 0 READ OR INPUT MODULE 3 MAXIMUM CURRENT (10X)
131 INPUT MODULE 4 PRESENT VALUE READ OR INPUT MODULE 4 PRESENT WINDING TEMP (10X)
132 INPUT MODULE 4 MINIMUM VALUE READ OR INPUT MODULE 4 MINIMUM WINDING TEMP (10X)
133 INPUT MODULE 4 MAXIMUM VALUE READ OR INPUT MODULE 4 MAXIMUM WINDING TEMP (10X)
134 0 READ OR INPUT MODULE 4 PRESENT CURRENT (10X)
135 0 READ OR INPUT MODULE 4 MAXIMUM CURRENT (10X)
136 INPUT MODULE 5 PRESENT VALUE READ OR INPUT MODULE 5 PRESENT WINDING TEMP (10X)
137 INPUT MODULE 5 MINIMUM VALUE READ OR INPUT MODULE 5 MINIMUM WINDING TEMP (10X)
138 INPUT MODULE 5 MAXIMUM VALUE READ OR INPUT MODULE 5 MAXIMUM WINDING TEMP (10X)
139 0 READ OR INPUT MODULE 5 PRESENT CURRENT (10X)
140 0 READ OR INPUT MODULE 5 MAXIMUM CURRENT (10X)
141 INPUT MODULE 6 PRESENT VALUE READ OR INPUT MODULE 6 PRESENT WINDING TEMP (10X)
142 INPUT MODULE 6 MINIMUM VALUE READ OR INPUT MODULE 6 MINIMUM WINDING TEMP (10X)
143 INPUT MODULE 6 MAXIMUM VALUE READ OR INPUT MODULE 6 MAXIMUM WINDING TEMP (10X)
144 0 READ OR INPUT MODULE 6 PRESENT CURRENT (10X)
145 0 READ OR INPUT MODULE 6 MAXIMUM CURRENT (10X)
146 INPUT MODULE 7 PRESENT VALUE READ OR INPUT MODULE 7 PRESENT WINDING TEMP (10X)
147 INPUT MODULE 7 MINIMUM VALUE READ OR INPUT MODULE 7 MINIMUM WINDING TEMP (10X)
148 INPUT MODULE 7 MAXIMUM VALUE READ OR INPUT MODULE 7 MAXIMUM WINDING TEMP (10X)
149 0 READ OR INPUT MODULE 7 PRESENT CURRENT (10X)
150 0 READ OR INPUT MODULE 7 MAXIMUM CURRENT (10X)
151 INPUT MODULE 8 PRESENT VALUE READ OR INPUT MODULE 8 PRESENT WINDING TEMP (10X)
152 INPUT MODULE 8 MINIMUM VALUE READ OR INPUT MODULE 8 MINIMUM WINDING TEMP (10X)
36 www.qualitrolcorp.com
Protocol Manual
37 www.qualitrolcorp.com
Protocol Manual
38 www.qualitrolcorp.com
Protocol Manual
39 www.qualitrolcorp.com
Protocol Manual
40 www.qualitrolcorp.com
Protocol Manual
41 www.qualitrolcorp.com
Protocol Manual
42 www.qualitrolcorp.com
Protocol Manual
43 www.qualitrolcorp.com
Protocol Manual
465 COOLING EXERCISER RUN TIME READ MINUTES FAN EXERCISER WILL RUN WHEN ACTIVE (N)
DAYS BETWEEN EXERCISER RUN TIME BEING ACTIVE
466 COOLING EXERCISER CYCLE TIME READ (N)
467 COOLING EXERCISER START TIME READ HOUR TO BEGIN FAN EXERCISER IN MILITARY TIME (N)
468 STARTING MONTH FOR SEASONAL SETPOINT READ RELAY FEATURE (1 - 12) (N)
469 STARTING DAY FOR SEASONAL SETPOINT READ RELAY FEATURE (1 - 31) (N)
470 ENDING MONTH FOR SEASONAL SETPOINT READ RELAY FEATURE (1 - 12) (N)
471 ENDING DAY FOR SEASONAL SETPOINT READ RELAY FEATURE (1 - 31) (N)
472 AMBIENT TEMPERATURE FORECAST SETPOINT READ RELAY FEATURE (N)
# OF HOURS TO EXCEED SETPOINT FOR ACTIVE
473 AMBIENT TEMPERATURE THRESHOLD HOURS READ FEATURE (N)
ROLLING PERIOD IN HOURS TO MEASURE THRESHOLD
474 AMBIENT TEMPERATURE MEASUREMENT PERIOD READ TEMP (N)
MODULE NUMBER MEASURING AMBIENT MODULE NUMBER IF THERE IS AN AMBIENT SENSOR
475 TEMPERATURE READ (N)
CB1 RUNNING CURRENT UPPER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
516 VALUE RD/WR (10X)
CB1 RUNNING CURRENT LOWER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
517 VALUE RD/WR (10X)
COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
518 CB1 INRUSH CURRENT UPPER SETPOINT VALUE RD/WR (10X)
COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
519 CB1 INRUSH CURRENT LOWER SETPOINT VALUE RD/WR (10X)
CB2 RUNNING CURRENT UPPER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
520 VALUE RD/WR (10X)
CB2 RUNNING CURRENT LOWER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
521 VALUE RD/WR (10X)
COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
522 CB2 INRUSH CURRENT UPPER SETPOINT VALUE RD/WR (10X)
COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
523 CB2 INRUSH CURRENT LOWER SETPOINT VALUE RD/WR (10X)
CB3 RUNNING CURRENT UPPER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
524 VALUE RD/WR (10X)
CB3 RUNNING CURRENT LOWER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
525 VALUE RD/WR (10X)
COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
526 CB3 INRUSH CURRENT UPPER SETPOINT VALUE RD/WR (10X)
COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
527 CB3 INRUSH CURRENT LOWER SETPOINT VALUE RD/WR (10X)
CB4 RUNNING CURRENT UPPER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
528 VALUE RD/WR (10X)
CB4 RUNNING CURRENT LOWER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
529 VALUE RD/WR (10X)
COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
530 CB4 INRUSH CURRENT UPPER SETPOINT VALUE RD/WR (10X)
COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
531 CB4 INRUSH CURRENT LOWER SETPOINT VALUE RD/WR (10X)
AVERAGE RUNNING CURRENT FROM LEARN MODE
532 CB1 RUNNING CURRENT AVERAGE READ (10X)
44 www.qualitrolcorp.com
Protocol Manual
560 CURRENT LOOP 1 CONTROL SIGNAL READ VALUE OF SIGNAL CONTROLLING LOOP 1 (10X)
561 CURRENT LOOP 2 CONTROL SIGNAL READ VALUE OF SIGNAL CONTROLLING LOOP 2 (10X)
562 CURRENT LOOP 3 CONTROL SIGNAL READ VALUE OF SIGNAL CONTROLLING LOOP 3 (10X)
563 CURRENT LOOP 4 CONTROL SIGNAL READ VALUE OF SIGNAL CONTROLLING LOOP 4 (10X)
564 CURRENT LOOP 1 MINIMUM SCALING RANGE READ MINIMUM SCALING VALUE FOR CURRENT LOOP 1 (10X)
565 CURRENT LOOP 2 MINIMUM SCALING RANGE READ MINIMUM SCALING VALUE FOR CURRENT LOOP 2 (10X)
566 CURRENT LOOP 3 MINIMUM SCALING RANGE READ MINIMUM SCALING VALUE FOR CURRENT LOOP 3 (10X)
567 CURRENT LOOP 4 MINIMUM SCALING RANGE READ MINIMUM SCALING VALUE FOR CURRENT LOOP 4 (10X)
568 CURRENT LOOP 1 MAXIMUM SCALING RANGE READ MAXIMUM SCALING VALUE FOR CURRENT LOOP 1 (10X)
569 CURRENT LOOP 2 MAXIMUM SCALING RANGE READ MAXIMUM SCALING VALUE FOR CURRENT LOOP 2 (10X)
570 CURRENT LOOP 3 MAXIMUM SCALING RANGE READ MAXIMUM SCALING VALUE FOR CURRENT LOOP 3 (10X)
571 CURRENT LOOP 4 MAXIMUM SCALING RANGE READ MAXIMUM SCALING VALUE FOR CURRENT LOOP 4 (10X)
45 www.qualitrolcorp.com
Protocol Manual
632 RELAY 1 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
633 RELAY 2 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
634 RELAY 3 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
635 RELAY 4 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
636 RELAY 5 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
637 RELAY 6 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
638 RELAY 7 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
639 RELAY 8 ACTUATION DELAY - HOURS VALUE RD/WR ACTUATION DELAY - HOURS (N)
640 RELAY 1 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
641 RELAY 2 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
642 RELAY 3 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
643 RELAY 4 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
644 RELAY 5 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
645 RELAY 6 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
646 RELAY 7 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
647 RELAY 8 ACTUATION DELAY - MINUTES VALUE RD/WR ACTUATION DELAY - MINUTES (N)
648 RELAY 1 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
649 RELAY 2 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
650 RELAY 3 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
651 RELAY 4 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
652 RELAY 5 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
653 RELAY 6 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
654 RELAY 7 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
655 RELAY 8 ACTUATION DELAY - SECONDS VALUE RD/WR ACTUATION DELAY - SECONDS (N)
691 TRANSLIFE 1 PRESENT CONSUMED LIFE RATE READ INSTANTANEOUS LIFE RATE (100X)
692 TRANSLIFE 2 PRESENT CONSUMED LIFE RATE READ INSTANTANEOUS LIFE RATE (100X)
693 TRANSLIFE 3 PRESENT CONSUMED LIFE RATE READ INSTANTANEOUS LIFE RATE (100X)
Analog Parameters
For Registers 702 thru 847 the parameters are 32 bits long with the even registers holding the low
word and the high registers holding the high word (e.g. 702 low word; 703 high word).
46 www.qualitrolcorp.com
Protocol Manual
TRANSLIFE 1; TEMPERATURE PROFILE, 1ST TOTAL WINDING TEMP TIME IN LOWEST TEMP RANGE
748 RANGE READ (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 2ND
750 RANGE READ TOTAL WINDING TEMP TIME IN 2ND TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 3RD
752 RANGE READ TOTAL WINDING TEMP TIME IN 3RD TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 4TH
754 RANGE READ TOTAL WINDING TEMP TIME IN 4TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 5TH
756 RANGE READ TOTAL WINDING TEMP TIME IN 5TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 6TH
758 RANGE READ TOTAL WINDING TEMP TIME IN 6TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 7TH
760 RANGE READ TOTAL WINDING TEMP TIME IN 7TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 8TH
762 RANGE READ TOTAL WINDING TEMP TIME IN 8TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 9TH
764 RANGE READ TOTAL WINDING TEMP TIME IN 9TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 10TH
766 RANGE READ TOTAL WINDING TEMP TIME IN 10TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 11TH
768 RANGE READ TOTAL WINDING TEMP TIME IN 11TH TEMP RANGE (N)
TRANSLIFE 1; TEMPERATURE PROFILE, 12TH TOTAL WINDING TEMP TIME IN HIGHEST TEMP RANGE
770 RANGE READ (N)
TRANSLIFE 2; TEMPERATURE PROFILE, 1ST TOTAL WINDING TEMP TIME IN LOWEST TEMP RANGE
772 RANGE READ (N)
TRANSLIFE 2; TEMPERATURE PROFILE, 2ND
774 RANGE READ TOTAL WINDING TEMP TIME IN 2ND TEMP RANGE (N)
TRANSLIFE 2; TEMPERATURE PROFILE, 3RD
776 RANGE READ TOTAL WINDING TEMP TIME IN 3RD TEMP RANGE (N)
TRANSLIFE 2; TEMPERATURE PROFILE, 4TH
778 RANGE READ TOTAL WINDING TEMP TIME IN 4TH TEMP RANGE (N)
TRANSLIFE 2; TEMPERATURE PROFILE, 5TH
780 RANGE READ TOTAL WINDING TEMP TIME IN 5TH TEMP RANGE (N)
47 www.qualitrolcorp.com
Protocol Manual
48 www.qualitrolcorp.com
Protocol Manual
String Parameters
REG # VARIABLE R/W DESCRIPTION
850 SERIAL NUMBER; 12 ASCII CHARACTERS READ SERIAL NUMBER[1] / SERIAL NUMBER[0]
851 SERIAL NUMBER CONTINUED READ SERIAL NUMBER[3] / SERIAL NUMBER [2]
852 SERIAL NUMBER CONTINUED READ SERIAL NUMBER[5] / SERIAL NUMBER [4]
853 SERIAL NUMBER CONTINUED READ SERIAL NUMBER[7] / SERIAL NUMBER [6]
854 SERIAL NUMBER CONTINUED READ SERIAL NUMBER[9] / SERIAL NUMBER [8]
855 SERIAL NUMBER CONTINUED READ SERIAL NUMBER[11] / SERIAL NUMBER [10]
856 MANUFACTURED DATE; 8 ASCII CHARACTERS READ MANUFACTURED DATE[1] / MANUFACTURED DATE [0]
857 MANUFACTURED DATE CONTINUED READ MANUFACTURED DATE[3] / MANUFACTURED DATE [2]
858 MANUFACTURED DATE CONTINUED READ MANUFACTURED DATE[5] / MANUFACTURED DATE [4]
859 MANUFACTURED DATE CONTINUED READ MANUFACTURED DATE[7] / MANUFACTURED DATE [6]
860 SUBSTATION NAME; 16 ASCII CHARACTERS READ SUBSTATION NAME[1] / SUBSTATION NAME[0]
861 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[3] / SUBSTATION NAME[2]
862 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[5] / SUBSTATION NAME[4]
863 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[7] / SUBSTATION NAME[6]
864 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[9] / SUBSTATION NAME[8]
865 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[11] / SUBSTATION NAME[10]
866 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[13] / SUBSTATION NAME[12]
867 SUBSTATION NAME CONTINUED READ SUBSTATION NAME[15] / SUBSTATION NAME[14]
868 EQUIPMENT NAME; 16 ASCII CHARACTERS READ EQUIPMENT NAME[1] / EQUIPMENT NAME[0]
869 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[3] / EQUIPMENT NAME[2]
870 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[5] / EQUIPMENT NAME[4]
871 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[7] / EQUIPMENT NAME[6]
872 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[9] / EQUIPMENT NAME[8]
873 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[11] / EQUIPMENT NAME[10]
874 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[13] / EQUIPMENT NAME[12]
875 EQUIPMENT NAME CONTINUED READ EQUIPMENT NAME[15] / EQUIPMENT NAME[14]
876 MODEL NUMBER; 8 ASCII CHARACTERS READ MODEL NUMBER[1] / MODEL NUMBER[0]
877 MODEL NUMBER CONTINUED READ MODEL NUMBER[3] / MODEL NUMBER[2]
878 MODEL NUMBER CONTINUED READ MODEL NUMBER[5] / MODEL NUMBER[4]
879 MODEL NUMBER CONTINUED READ MODEL NUMBER[7] / MODEL NUMBER[6]
Registers 900 thru 907 have the hex codes of the hardware types for the input modules. The types
are explained in the description side of the registers
49 www.qualitrolcorp.com
Protocol Manual
Registers 908 thru 979 are packed numbers. For example: reading register 908 gives a decimal
number of 3122. Converting this to hex gives 0C32. Split the bytes in half and it would read 12
hours and 32 minutes.
50 www.qualitrolcorp.com
Protocol Manual
51 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
For registers 1000 thru 1133 the parameters are 32 bits long with the even registers holding the low
word and the high registers holding the high word (e.g. 1000 low word; 1001 high word).
REG # VARIABLE R/W DESCRIPTION
1000 LTC, TAP POSITION -16 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-16)
1002 LTC, TAP POSITION -15 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-15)
1004 LTC, TAP POSITION -14 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-14)
1006 LTC, TAP POSITION -13 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-13)
1008 LTC, TAP POSITION -12 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-12)
1010 LTC, TAP POSITION -11 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-11)
1012 LTC, TAP POSITION -10 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-10)
1014 LTC, TAP POSITION -9 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-9)
1016 LTC, TAP POSITION -8 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-8)
1018 LTC, TAP POSITION -7 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-7)
1020 LTC, TAP POSITION -6 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-6)
1022 LTC, TAP POSITION -5 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-5)
1024 LTC, TAP POSITION -4 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-4)
1026 LTC, TAP POSITION -3 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-3)
1028 LTC, TAP POSITION -2 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-2)
1030 LTC, TAP POSITION -1 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (-1)
1032 LTC, TAP POSITION +0 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+0)
1034 LTC, TAP POSITION +1 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+1)
1036 LTC, TAP POSITION +2 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+2)
1038 LTC, TAP POSITION +3 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+3)
1040 LTC, TAP POSITION +4 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+4)
1042 LTC, TAP POSITION +5 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+5)
1044 LTC, TAP POSITION +6 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+6)
1046 LTC, TAP POSITION +7 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+7)
1048 LTC, TAP POSITION +8 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+8)
1050 LTC, TAP POSITION +9 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+9)
1052 LTC, TAP POSITION +10 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+10)
1054 LTC, TAP POSITION +11 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+11)
1056 LTC, TAP POSITION +12 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+12)
1058 LTC, TAP POSITION +13 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+13)
1060 LTC, TAP POSITION +14 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+14)
1062 LTC, TAP POSITION +15 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+15)
1064 LTC, TAP POSITION +16 TOTAL TAP COUNTS READ TOTAL TAP COUNTS FOR TAP POSITION (+16)
1066 LTC, TAP POSITION -16 TOTAL RUN TIME READ TOTAL RUN TIME FOR TAP POSITION (-16)
1068 LTC, TAP POSITION -15 TOTAL RUN TIME READ TOTAL RUN TIME FOR TAP POSITION (-15)
1070 LTC, TAP POSITION -14 TOTAL RUN TIME READ TOTAL RUN TIME FOR TAP POSITION (-14)
1072 LTC, TAP POSITION -13 TOTAL RUN TIME READ TOTAL RUN TIME FOR TAP POSITION (-13)
1074 LTC, TAP POSITION -12 TOTAL RUN TIME READ TOTAL RUN TIME FOR TAP POSITION (-12)
52 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
Registers 1134 to 1143 are scaled analog values (e.g. N, 10X, 100X, 1000X)
53 www.qualitrolcorp.com
Protocol Manual
String Parameters
REG # VARIABLE R/W DESCRIPTION
1200 INPUT MODULE 1 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 1 NAME[1] / INPUT MODULE 1 NAME[0]
1201 INPUT MODULE 1 NAME; CONTINUED READ INPUT MODULE 1 NAME[3] / INPUT MODULE 1 NAME[2]
1202 INPUT MODULE 1 NAME; CONTINUED READ INPUT MODULE 1 NAME[5] / INPUT MODULE 1 NAME[4]
1203 INPUT MODULE 1 NAME; CONTINUED READ INPUT MODULE 1 ZERO / INPUT MODULE 1 NAME[6]
1204 INPUT MODULE 2 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 2 NAME[1] / INPUT MODULE 2 NAME[0]
1205 INPUT MODULE 2 NAME; CONTINUED READ INPUT MODULE 2 NAME[3] / INPUT MODULE 2 NAME[2]
1206 INPUT MODULE 2 NAME; CONTINUED READ INPUT MODULE 2 NAME[5] / INPUT MODULE 2 NAME[4]
1207 INPUT MODULE 2 NAME; CONTINUED READ INPUT MODULE 2 ZERO / INPUT MODULE 2 NAME[6]
1208 INPUT MODULE 3 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 3 NAME[1] / INPUT MODULE 3 NAME[0]
1209 INPUT MODULE 3 NAME; CONTINUED READ INPUT MODULE 3 NAME[3] / INPUT MODULE 3 NAME[2]
1210 INPUT MODULE 3 NAME; CONTINUED READ INPUT MODULE 3 NAME[5] / INPUT MODULE 3 NAME[4]
1211 INPUT MODULE 3 NAME; CONTINUED READ INPUT MODULE 3 ZERO / INPUT MODULE 3 NAME[6]
1212 INPUT MODULE 4 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 4 NAME[1] / INPUT MODULE 4 NAME[0]
1213 INPUT MODULE 4 NAME; CONTINUED READ INPUT MODULE 4 NAME[3] / INPUT MODULE 4 NAME[2]
1214 INPUT MODULE 4 NAME; CONTINUED READ INPUT MODULE 4 NAME[5] / INPUT MODULE 4 NAME[4]
1215 INPUT MODULE 4 NAME; CONTINUED READ INPUT MODULE 4 ZERO / INPUT MODULE 4 NAME[6]
1216 INPUT MODULE 5 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 5 NAME[1] / INPUT MODULE 5 NAME[0]
1217 INPUT MODULE 5 NAME; CONTINUED READ INPUT MODULE 5 NAME[3] / INPUT MODULE 5 NAME[2]
1218 INPUT MODULE 5 NAME; CONTINUED READ INPUT MODULE 5 NAME[5] / INPUT MODULE 5 NAME[4]
1219 INPUT MODULE 5 NAME; CONTINUED READ INPUT MODULE 5 ZERO / INPUT MODULE 5 NAME[6]
1220 INPUT MODULE 6 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 6 NAME[1] / INPUT MODULE 6 NAME[0]
1221 INPUT MODULE 6 NAME; CONTINUED READ INPUT MODULE 6 NAME[3] / INPUT MODULE 6 NAME[2]
1222 INPUT MODULE 6 NAME; CONTINUED READ INPUT MODULE 6 NAME[5] / INPUT MODULE 6 NAME[4]
1223 INPUT MODULE 6 NAME; CONTINUED READ INPUT MODULE 6 ZERO / INPUT MODULE 6 NAME[6]
1224 INPUT MODULE 7 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 7 NAME[1] / INPUT MODULE 7 NAME[0]
1225 INPUT MODULE 7 NAME; CONTINUED READ INPUT MODULE 7 NAME[3] / INPUT MODULE 7 NAME[2]
1226 INPUT MODULE 7 NAME; CONTINUED READ INPUT MODULE 7 NAME[5] / INPUT MODULE 7 NAME[4]
1227 INPUT MODULE 7 NAME; CONTINUED READ INPUT MODULE 7 ZERO / INPUT MODULE 7 NAME[6]
1228 INPUT MODULE 8 NAME; 7 ASCII CHARACTERS READ INPUT MODULE 8 NAME[1] / INPUT MODULE 8 NAME[0]
1229 INPUT MODULE 8 NAME; CONTINUED READ INPUT MODULE 8 NAME[3] / INPUT MODULE 8 NAME[2]
1230 INPUT MODULE 8 NAME; CONTINUED READ INPUT MODULE 8 NAME[5] / INPUT MODULE 8 NAME[4]
1231 INPUT MODULE 8 NAME; CONTINUED READ INPUT MODULE 8 ZERO / INPUT MODULE 8 NAME[6]
HOT SPOT MODULE 1; PROBE 1 NAME; 7 ASCII
1232 CHARS READ MODULE 1; PROBE 1 NAME[1] / PROBE 1 NAME[0]
HOT SPOT MODULE 1; PROBE 1 NAME;
1233 CONTINUED READ MODULE 1; PROBE 1 NAME[3] / PROBE 1 NAME[2]
HOT SPOT MODULE 1; PROBE 1 NAME;
1234 CONTINUED READ MODULE 1; PROBE 1 NAME[5] / PROBE 1 NAME[4]
HOT SPOT MODULE 1; PROBE 1 NAME;
1235 CONTINUED READ MODULE 1; PROBE 1 ZERO / PROBE 1 NAME[6]
HOT SPOT MODULE 1; PROBE 2 NAME; 7 ASCII
1236 CHARS READ MODULE 1; PROBE 2 NAME[1] / PROBE 2 NAME[0]
HOT SPOT MODULE 1; PROBE 2 NAME;
1237 CONTINUED READ MODULE 1; PROBE 2 NAME[3] / PROBE 2 NAME[2]
HOT SPOT MODULE 1; PROBE 2 NAME;
1238 CONTINUED READ MODULE 1; PROBE 2 NAME[5] / PROBE 2 NAME[4]
HOT SPOT MODULE 1; PROBE 2 NAME;
1239 CONTINUED READ MODULE 1; PROBE 2 ZERO / PROBE 2 NAME[6]
HOT SPOT MODULE 1; PROBE 3 NAME; 7 ASCII
1240 CHARS READ MODULE 1; PROBE 3 NAME[1] / PROBE 3 NAME[0]
54 www.qualitrolcorp.com
Protocol Manual
55 www.qualitrolcorp.com
Protocol Manual
56 www.qualitrolcorp.com
Protocol Manual
57 www.qualitrolcorp.com
Protocol Manual
58 www.qualitrolcorp.com
Protocol Manual
59 www.qualitrolcorp.com
Protocol Manual
60 www.qualitrolcorp.com
Protocol Manual
61 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
Registers 1500 thru 1507, see appropriate scaling (e.g. N, 10X, 100X, 1000X)
String Parameters
Registers 1508 thru 1523.
62 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
Registers 1524 thru 2315; see appropriate scaling (e.g. N, 10X, 100X, 1000X)
63 www.qualitrolcorp.com
Protocol Manual
1600 INPUT MODULE 1; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1602 INPUT MODULE 2; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1604 INPUT MODULE 3; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1606 INPUT MODULE 4; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1608 INPUT MODULE 5; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1610 INPUT MODULE 6; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1612 INPUT MODULE 7; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1614 INPUT MODULE 8; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1616 INPUT MODULE 1; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1618 INPUT MODULE 2; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1620 INPUT MODULE 3; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1622 INPUT MODULE 4; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1624 INPUT MODULE 5; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1626 INPUT MODULE 6; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1628 INPUT MODULE 7; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1630 INPUT MODULE 8; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
1632 INPUT MODULE 1; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1634 INPUT MODULE 2; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1636 INPUT MODULE 3; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1638 INPUT MODULE 4; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1640 INPUT MODULE 5; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1642 INPUT MODULE 6; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1644 INPUT MODULE 7; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1646 INPUT MODULE 8; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
1648 INPUT MODULE 1; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1650 INPUT MODULE 2; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1652 INPUT MODULE 3; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1654 INPUT MODULE 4; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1656 INPUT MODULE 5; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1658 INPUT MODULE 6; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
1660 INPUT MODULE 7; SCALING GAIN VALUE READ SCALING GAIN CALIBRATION VALUE (1000X)
64 www.qualitrolcorp.com
Protocol Manual
65 www.qualitrolcorp.com
Protocol Manual
66 www.qualitrolcorp.com
Protocol Manual
67 www.qualitrolcorp.com
Protocol Manual
68 www.qualitrolcorp.com
Protocol Manual
69 www.qualitrolcorp.com
Protocol Manual
70 www.qualitrolcorp.com
Protocol Manual
Registers 2316 thru 2411 are packed numbers. For example: reading register 908 gives a decimal
number of 3122. Converting this to hex gives 0C32. Split the bytes in half and it would read 12
hours and 32 minutes.
71 www.qualitrolcorp.com
Protocol Manual
72 www.qualitrolcorp.com
Protocol Manual
73 www.qualitrolcorp.com
Protocol Manual
Binary Parameters
REG # VARIABLE R/W DESCRIPTION
2500 INPUT MODULE 9 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2501 INPUT MODULE 10 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2502 INPUT MODULE 11 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2503 INPUT MODULE 12 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2504 INPUT MODULE 13 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2505 INPUT MODULE 14 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2506 INPUT MODULE 15 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2507 INPUT MODULE 16 ENABLED/DISABLED RD/WR 1 = ENABLED; 0 = DISABLED
2508 INPUT MODULE 9 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2509 INPUT MODULE 10 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2510 INPUT MODULE 11 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2511 INPUT MODULE 12 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2512 INPUT MODULE 13 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2513 INPUT MODULE 14 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2514 INPUT MODULE 15 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2515 INPUT MODULE 16 READ ERROR READ 1 = READ ERROR; 0 = VALID READ
2516 INPUT MODULE 9 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2517 INPUT MODULE 10 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2518 INPUT MODULE 11 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2519 INPUT MODULE 12 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2520 INPUT MODULE 13 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2521 INPUT MODULE 14 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2522 INPUT MODULE 15 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
2523 INPUT MODULE 16 SCALING ENABLED READ 1 = SCALING ENABLED; 0 = DISABLED
Registers 2600 thru 2607 have the hex codes of the hardware types for the input modules. The types
are explained in the description side of the registers
74 www.qualitrolcorp.com
Protocol Manual
Analog Parameters
Values in registers 2608 thru 2935 have been scaled according to their function to offer the greatest
possible resolution. If the description of the value has a (N) then there is no scaling. A (10X) means
the value has been multiplied by 10 and needs to be divided by 10 to read the actual value (e.g. if the
value in the 509ITM is 123.4 then it will be transmitted 1234). A (100X) means the value was
multiplied by 100 and needs to be divided by 100 to read the actual value (e.g. if the value in the
509ITM is 12.34 then it will be transmitted as 1234).
REG # VARIABLE R/W DESCRIPTION
ALL MODULES BUT CT, WINDING
TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
OR INPUT MODULE 9 PRESENT WINDING TEMP
2608 INPUT MODULE 9 PRESENT VALUE READ (10X)
2609 INPUT MODULE 9 MINIMUM VALUE READ OR INPUT MODULE 9 MINIMUM WINDING TEMP (10X)
OR INPUT MODULE 9 MAXIMUM WINDING TEMP
2610 INPUT MODULE 9 MAXIMUM VALUE READ (10X)
2611 0 READ OR INPUT MODULE 9 PRESENT CURRENT (10X)
2612 0 READ OR INPUT MODULE 9 MAXIMUM CURRENT (10X)
OR INPUT MODULE 10 PRESENT WINDING TEMP
2613 INPUT MODULE 10 PRESENT VALUE READ (10X)
OR INPUT MODULE 10 MINIMUM WINDING TEMP
2614 INPUT MODULE 10 MINIMUM VALUE READ (10X)
OR INPUT MODULE 10 MAXIMUM WINDING TEMP
2615 INPUT MODULE 10 MAXIMUM VALUE READ (10X)
2616 0 READ OR INPUT MODULE 10 PRESENT CURRENT (10X)
2617 0 READ OR INPUT MODULE 10 MAXIMUM CURRENT (10X)
OR INPUT MODULE 11 PRESENT WINDING TEMP
2618 INPUT MODULE 11 PRESENT VALUE READ (10X)
OR INPUT MODULE 11 MINIMUM WINDING TEMP
2619 INPUT MODULE 11 MINIMUM VALUE READ (10X)
OR INPUT MODULE 11 MAXIMUM WINDING TEMP
2620 INPUT MODULE 11 MAXIMUM VALUE READ (10X)
2621 0 READ OR INPUT MODULE 11 PRESENT CURRENT (10X)
2622 0 READ OR INPUT MODULE 11 MAXIMUM CURRENT (10X)
OR INPUT MODULE 12 PRESENT WINDING TEMP
2623 INPUT MODULE 12 PRESENT VALUE READ (10X)
OR INPUT MODULE 12 MINIMUM WINDING TEMP
2624 INPUT MODULE 12 MINIMUM VALUE READ (10X)
OR INPUT MODULE 12 MAXIMUM WINDING TEMP
2625 INPUT MODULE 12 MAXIMUM VALUE READ (10X)
2626 0 READ OR INPUT MODULE 12 PRESENT CURRENT (10X)
2627 0 READ OR INPUT MODULE 12 MAXIMUM CURRENT (10X)
OR INPUT MODULE 13 PRESENT WINDING TEMP
2628 INPUT MODULE 13 PRESENT VALUE READ (10X)
OR INPUT MODULE 13 MINIMUM WINDING TEMP
2629 INPUT MODULE 13 MINIMUM VALUE READ (10X)
OR INPUT MODULE 13 MAXIMUM WINDING TEMP
2630 INPUT MODULE 13 MAXIMUM VALUE READ (10X)
2631 0 READ OR INPUT MODULE 13 PRESENT CURRENT (10X)
2632 0 READ OR INPUT MODULE 13 MAXIMUM CURRENT (10X)
OR INPUT MODULE 14 PRESENT WINDING TEMP
2633 INPUT MODULE 14 PRESENT VALUE READ (10X)
OR INPUT MODULE 14 MINIMUM WINDING TEMP
2634 INPUT MODULE 14 MINIMUM VALUE READ (10X)
75 www.qualitrolcorp.com
Protocol Manual
76 www.qualitrolcorp.com
Protocol Manual
2688 INPUT MODULE 9; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2689 INPUT MODULE 10; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2690 INPUT MODULE 11; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2691 INPUT MODULE 12; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2692 INPUT MODULE 13; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2693 INPUT MODULE 14; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2694 INPUT MODULE 15; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2695 INPUT MODULE 16; CT RATIO PRIMARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2696 INPUT MODULE 9; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2697 INPUT MODULE 10; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2698 INPUT MODULE 11; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2699 INPUT MODULE 12; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2700 INPUT MODULE 13; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2701 INPUT MODULE 14; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2702 INPUT MODULE 15; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2703 INPUT MODULE 16; CT RATIO SECONDARY # READ IF CT MODULE TYPE; HOLDS CT RATIO # (1000X)
2704 INPUT MODULE 9; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
2705 INPUT MODULE 10; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
2706 INPUT MODULE 11; SCALING OFFSET VALUE READ SCALING OFFSET CALIBRATION VALUE (1000X)
77 www.qualitrolcorp.com
Protocol Manual
78 www.qualitrolcorp.com
Protocol Manual
79 www.qualitrolcorp.com
Protocol Manual
80 www.qualitrolcorp.com
Protocol Manual
81 www.qualitrolcorp.com
Protocol Manual
82 www.qualitrolcorp.com
Protocol Manual
83 www.qualitrolcorp.com
Protocol Manual
Registers 3000 thru 3071 are packed numbers. For example: reading register 908 gives a decimal
number of 3122. Converting this to hex gives 0C32. Split the bytes in half and it would read 12
hours and 32 minutes.
REG # VARIABLE R/W DESCRIPTION
ALL MODULES BUT CT, WINDING
TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
INPUT MODULE 9 MAXIMUM VALUE TIME &
3000 DATE READ HOURS BYTE / MINUTES BYTE
INPUT MODULE 9 MAXIMUM VALUE TIME &
3001 DATE READ SECONDS BYTE / MONTHS BYTE
INPUT MODULE 9 MAXIMUM VALUE TIME &
3002 DATE READ DAYS BYTE / YEARS BYTE
INPUT MODULE 10 MAXIMUM VALUE TIME &
3003 DATE READ HOURS BYTE / MINUTES BYTE
84 www.qualitrolcorp.com
Protocol Manual
85 www.qualitrolcorp.com
Protocol Manual
86 www.qualitrolcorp.com
Protocol Manual
String Parameters
Registers 3072 thru 3119.
REG # VARIABLE R/W DESCRIPTION
ALL MODULES BUT CT, WINDING
TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
INPUT MODULE 9 NAME; 7 ASCII INPUT MODULE 1 NAME[1] / INPUT MODULE 1
3072 CHARACTERS READ NAME[0]
INPUT MODULE 1 NAME[3] / INPUT MODULE 1
3073 INPUT MODULE 9 NAME; CONTINUED READ NAME[2]
INPUT MODULE 1 NAME[5] / INPUT MODULE 1
3074 INPUT MODULE 9 NAME; CONTINUED READ NAME[4]
3075 INPUT MODULE 9 NAME; CONTINUED READ INPUT MODULE 1 ZERO / INPUT MODULE 1 NAME[6]
INPUT MODULE 10 NAME; 7 ASCII INPUT MODULE 2 NAME[1] / INPUT MODULE 2
3076 CHARACTERS READ NAME[0]
INPUT MODULE 2 NAME[3] / INPUT MODULE 2
3077 INPUT MODULE 10 NAME; CONTINUED READ NAME[2]
INPUT MODULE 2 NAME[5] / INPUT MODULE 2
3078 INPUT MODULE 10 NAME; CONTINUED READ NAME[4]
3079 INPUT MODULE 10 NAME; CONTINUED READ INPUT MODULE 2 ZERO / INPUT MODULE 2 NAME[6]
INPUT MODULE 11 NAME; 7 ASCII INPUT MODULE 3 NAME[1] / INPUT MODULE 3
3080 CHARACTERS READ NAME[0]
INPUT MODULE 3 NAME[3] / INPUT MODULE 3
3081 INPUT MODULE 11 NAME; CONTINUED READ NAME[2]
INPUT MODULE 3 NAME[5] / INPUT MODULE 3
3082 INPUT MODULE 11 NAME; CONTINUED READ NAME[4]
3083 INPUT MODULE 11 NAME; CONTINUED READ INPUT MODULE 3 ZERO / INPUT MODULE 3 NAME[6]
INPUT MODULE 12 NAME; 7 ASCII INPUT MODULE 4 NAME[1] / INPUT MODULE 4
3084 CHARACTERS READ NAME[0]
INPUT MODULE 4 NAME[3] / INPUT MODULE 4
3085 INPUT MODULE 12 NAME; CONTINUED READ NAME[2]
INPUT MODULE 4 NAME[5] / INPUT MODULE 4
3086 INPUT MODULE 12 NAME; CONTINUED READ NAME[4]
3087 INPUT MODULE 12 NAME; CONTINUED READ INPUT MODULE 4 ZERO / INPUT MODULE 4 NAME[6]
INPUT MODULE 13 NAME; 7 ASCII INPUT MODULE 5 NAME[1] / INPUT MODULE 5
3088 CHARACTERS READ NAME[0]
INPUT MODULE 5 NAME[3] / INPUT MODULE 5
3089 INPUT MODULE 13 NAME; CONTINUED READ NAME[2]
INPUT MODULE 5 NAME[5] / INPUT MODULE 5
3090 INPUT MODULE 13 NAME; CONTINUED READ NAME[4]
3091 INPUT MODULE 13 NAME; CONTINUED READ INPUT MODULE 5 ZERO / INPUT MODULE 5 NAME[6]
INPUT MODULE 14 NAME; 7 ASCII INPUT MODULE 6 NAME[1] / INPUT MODULE 6
3092 CHARACTERS READ NAME[0]
INPUT MODULE 6 NAME[3] / INPUT MODULE 6
3093 INPUT MODULE 14 NAME; CONTINUED READ NAME[2]
INPUT MODULE 6 NAME[5] / INPUT MODULE 6
3094 INPUT MODULE 14 NAME; CONTINUED READ NAME[4]
3095 INPUT MODULE 14 NAME; CONTINUED READ INPUT MODULE 6 ZERO / INPUT MODULE 6 NAME[6]
INPUT MODULE 15 NAME; 7 ASCII INPUT MODULE 7 NAME[1] / INPUT MODULE 7
3096 CHARACTERS READ NAME[0]
INPUT MODULE 7 NAME[3] / INPUT MODULE 7
3097 INPUT MODULE 15 NAME; CONTINUED READ NAME[2]
INPUT MODULE 7 NAME[5] / INPUT MODULE 7
3098 INPUT MODULE 15 NAME; CONTINUED READ NAME[4]
3099 INPUT MODULE 15 NAME; CONTINUED READ INPUT MODULE 7 ZERO / INPUT MODULE 7 NAME[6]
3100 INPUT MODULE 16 NAME; 7 ASCII READ INPUT MODULE 8 NAME[1] / INPUT MODULE 8
87 www.qualitrolcorp.com
Protocol Manual
88 www.qualitrolcorp.com
Protocol Manual
Interoperability
The pages in this section have been extracted from the 60870-5-101 © IEC:2003, Section 8. The
section numbers below have been purposely retained from that document for reference.
This companion standard presents sets of parameters and alternatives from which subsets have to
be selected to implement particular telecontrol systems. Certain parameter values, such as the
number of octets in the COMMON ADDRESS of ASDUs represent mutually exclusive alternatives.
This means that only one value of the defined parameters is admitted per system. Other parameters,
such as the listed set of different process information in command and in monitor direction allow the
specification of the complete set or subsets, as appropriate for given applications. This Clause
summarizes the parameters of the previous Clauses to facilitate a suitable selection for a specific
application. If a system is composed of equipment stemming from different manufacturers it is
necessary that all partners agree on the selected parameters.
The selected parameters should be marked in the white boxes as follows:
89 www.qualitrolcorp.com
Protocol Manual
The possible selection (blank, X, R, or B) is specified for each specific Clause or parameter.
System or device
System definition
Controlling station definition (master)
Controlled station definition (slave)
Network Configuration
Point-to-point Multipoint-party line
Multiple point-to-point Multipoint-star
Physical Layer
Transmission Speed (control direction)
Unbalanced interchange Unbalanced interchange Balanced interchange
Circuit V.24/V.28 Circuit V.24/V.28 Circuit X.24/X.27
Standard Recommended if >1 200 bit/s
100 bit/s 2400 bit/s 2400 bit/s
56000 bit/s
200 bit/s 4800 bit/s 4800 bit/s
64000 bit/s
300 bit/s 9600 bit/s 9600 bit/s
600 bit/s 19200 bit/s
1200 bit/s 38400 bit/s
Transmission speed (monitor direction)
Unbalanced interchange Unbalanced interchange Balanced interchange
Circuit V.24/V.28 Circuit V.24/V.28 Circuit X.24/X.27
Standard Recommended if >1 200 bit/s
100 bit/s 2400 bit/s 2400 bit/s
56000 bit/s
200 bit/s 4800 bit/s 4800 bit/s
64000 bit/s
300 bit/s 9600 bit/s 9600 bit/s
600 bit/s 19200 bit/s
1200 bit/s 38400 bit/s
Link Layer
Frame format FT 1.2, single character 1 and the fixed time out interval are used exclusively in this
companion standard.
90 www.qualitrolcorp.com
Protocol Manual
Structured
Unstructured
Frame length
255 Maximum length L (control direction)
255 Maximum length L (monitor direction)
Configurable Time during which repetitions are permitted (Trp) or number of repetitions
Note: In response to a class 2 poll, a controlled station may respond with class 1 data when there is
no class 2 data available.
Application Layer
Transmission mode for application data
Mode 1 (Least significant octet first), as defined in clause 4.10 of IEC 60870-5-4, is used exclusively
in this companion standard.
91 www.qualitrolcorp.com
Protocol Manual
92 www.qualitrolcorp.com
Protocol Manual
File transfer
93 www.qualitrolcorp.com
Protocol Manual
activation termination
request or requested
background scan
periodic, cyclic
spontaneous
deactivation
file transfer
activation
initialized
20 37
1 2 3 4 5 6 7 8 9 10 11 12 13 to to 44 45 46 47
36 41
<1> M_SP_NA_1 X X X X X X
<2> M_SP_TA_1 X X X X
<3> M_DP_NA_1 X X X X X X
<4> M_DP_TA_1 X X X X
<5> M_ST_NA_1 X X X X X X
<6> M_ST_TA_1 X X X X
<7> M_BO_NA_1 X X X X
<8> M_BO_TA_1 X X
<9> M_ME_NA_1 X X X X X
<10> M_ME_TA_1 X X
<11> M_ME_NB_1 X X X X X
<12> M_ME_TB_1 X X
<13> M_ME_NC_1 X X X X X
<14> M_ME_TC_1 X X
<15> M_IT_NA_1 X X
<16> M_IT_TA_1 X X
<17> M_EP_TA_1 X
<18> M_EP_TB_1 X
<19> M_EP_TC_1 X
<20> M_PS_NA_1 X X X X X X
<21> M_ME_ND_1 X X X X X
<30> M_SP_TB_1 X X X X
<31> M_DP_TB_1 X X X X
<32> M_ST_TB_1 X X X X
94 www.qualitrolcorp.com
Protocol Manual
activation termination
request or requested
background scan
periodic, cyclic
spontaneous
deactivation
file transfer
activation
initialized
20 37
1 2 3 4 5 6 7 8 9 10 11 12 13 to to 44 45 46 47
36 41
<33> M_BO_TB_1 X X
<34> M_ME_TD_1 X X
<35> M_ME_TE_1 X X
<36> M_ME_TF_1 X X
<37> M_IT_TB_1 X X
<38> M_EP_TD_1 X
<39> M_EP_TE_1 X
<40> M_EP_TF_1 X
<45> C_SC_NA_1 X X X X X X X X X
<46> C_DC_NA_1 X X X X X X X X X
<47> C_RC_NA_1 X X X X X X X X X
<48> C_SE_NA_1 X X X X X X X X X
<49> C_SE_NB_1 X X X X X X X X X
<50> C_SE_NC_1 X X X X X X X X X
<51> C_BO_NA_1 X X X X X X X X X
<70> M_EI_NA_1* X
<100> C_IC_NA_1 X X X X X X X X X
<101> C_CI_NA_1 X X X X X X X
<102> C_RD_NA_1 X X X X X
<103> C_CS_NA_1 X X X X X X X
<104> C_TS_NA_1 X X X X X X
<105> C_RP_NA_1 X X X X X X
<106> C_CD_NA_1 X X X X X X X
<110> P_ME_NA_1
<111> P_ME_NB_1
<112> P_ME_NC_1
<113> P_AC_NA_1
95 www.qualitrolcorp.com
Protocol Manual
activation termination
request or requested
background scan
periodic, cyclic
spontaneous
deactivation
file transfer
activation
initialized
20 37
1 2 3 4 5 6 7 8 9 10 11 12 13 to to 44 45 46 47
36 41
<120> F_FR_NA_1
<121> F_SR_NA_1
<122> F_SC_NA_1
<123> F_LS_NA_1
<124> F_AF_NA_1
<125> F_SG_NA_1
<126> F_DR_TA_1*
* Blank or X only
96 www.qualitrolcorp.com
Protocol Manual
Station interrogation
global
group 1 group 7 group 13
group 2 group 8 group l4
group 3 group 9 group 15
group 4 group 10 group 16
group 5 group 11
group 6 group 12 Information object addresses assigned to each
group must be show in a separate table
Clock synchronization
Clock synchronization
Day of week used
RES1, GEN (time tag substituted/ not substituted) used
SU-bit (summertime) used
Command transmission
Direct command transmission Select and execute command
Direct set point command transmission Select and execute set point command
C_SE_ACTTERM used
No additional definition
Short pulse duration (duration determined by a system parameter in the outstation)
Long pulse duration (duration determined by a system parameter in the outstation)
Persistent output
Transmission of Integrated totals
Mode A: Local freeze with spontaneous
Mode B: Local freeze with counter
Mode C Freeze and transmit by counter interrogation
Mode C Freeze by counter-interrogation command, frozen values reported
Counter read
97 www.qualitrolcorp.com
Protocol Manual
File transfer
File transfer in monitor direction
Transparent file
Transmission of disturbance data of protection
Transmission of sequences of events
Transmission of sequences of recorded analog values
File transfer in control direction
Transparent file
Background scan
Background scan
Acquisition of transmission delay
Acquisition of transmission delay
98 www.qualitrolcorp.com
Protocol Manual
99 www.qualitrolcorp.com
Protocol Manual
BINARY INPUT
I/O ADD DATA VARIABLE DESCRIPTION
44 INPUT MODULE 3 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
45 INPUT MODULE 4 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
46 INPUT MODULE 5 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
47 INPUT MODULE 6 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
48 INPUT MODULE 7 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
49 INPUT MODULE 8 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
BINARY OUTPUT
I/O ADD DATA VARIABLE DESCRIPTION
50 RELAY 1 ENABLED 1 = ENABLED; 0 = DISABLED
51 RELAY 2 ENABLED 1 = ENABLED; 0 = DISABLED
52 RELAY 3 ENABLED 1 = ENABLED; 0 = DISABLED
53 RELAY 4 ENABLED 1 = ENABLED; 0 = DISABLED
54 RELAY 5 ENABLED 1 = ENABLED; 0 = DISABLED
55 RELAY 6 ENABLED 1 = ENABLED; 0 = DISABLED
56 RELAY 7 ENABLED 1 = ENABLED; 0 = DISABLED
57 RELAY 8 ENABLED 1 = ENABLED; 0 = DISABLED
58 INPUT MODULE MAX/MIN RESET PULSE/RESET (1)
59 COOLING MONITOR MAX/MIN RESET PULSE/RESET (1)
60 LATCHED RELAYS RESET PULSE/RESET (1)
61 RELAY 1 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
62 RELAY 2 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
63 RELAY 3 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
64 RELAY 4 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
65 RELAY 5 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
66 RELAY 6 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
67 RELAY 7 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
68 RELAY 8 AUTO/MANUAL 1 = MANUAL OPERATION; 0 = AUTOMATIC
69 INPUT MODULE 1 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
70 INPUT MODULE 2 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
71 INPUT MODULE 3 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
72 INPUT MODULE 4 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
73 INPUT MODULE 5 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
74 INPUT MODULE 6 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
75 INPUT MODULE 7 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
76 INPUT MODULE 8 ENABLED/DISABLED 1 = ENABLED; 0 = DISABLED
BINARY INPUT
I/O ADD DATA VARIABLE DESCRIPTION
77 INPUT MODULE 1 READ ERROR 1 = READ ERROR; 0 = VALID READ
78 INPUT MODULE 2 READ ERROR 1 = READ ERROR; 0 = VALID READ
79 INPUT MODULE 3 READ ERROR 1 = READ ERROR; 0 = VALID READ
80 INPUT MODULE 4 READ ERROR 1 = READ ERROR; 0 = VALID READ
81 INPUT MODULE 5 READ ERROR 1 = READ ERROR; 0 = VALID READ
82 INPUT MODULE 6 READ ERROR 1 = READ ERROR; 0 = VALID READ
100 www.qualitrolcorp.com
Protocol Manual
BINARY INPUT
I/O ADD DATA VARIABLE DESCRIPTION
83 INPUT MODULE 7 READ ERROR 1 = READ ERROR; 0 = VALID READ
84 INPUT MODULE 8 READ ERROR 1 = READ ERROR; 0 = VALID READ
85 INPUT MODULE 1 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
86 INPUT MODULE 2 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
87 INPUT MODULE 3 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
88 INPUT MODULE 4 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
89 INPUT MODULE 5 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
90 INPUT MODULE 6 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
91 INPUT MODULE 7 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
92 INPUT MODULE 8 CUSTOM SCALING 1 = ENABLED; 0 = DISABLED
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
100 RELAY 1, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
101 RELAY 2, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
102 RELAY 3, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
103 RELAY 4, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
104 RELAY 5, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
105 RELAY 6, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
106 RELAY 7, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
107 RELAY 8, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
108 RELAY 1, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
109 RELAY 2, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
110 RELAY 3, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
111 RELAY 4, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
112 RELAY 5, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
113 RELAY 6, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
114 RELAY 7, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
115 RELAY 8, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
ALL MODULES BUT CT, WINDING TEMPERATURE IF THE MODULE IS A CT, WINDING TEMPERATURE
116 INPUT MODULE 1 PRESENT VALUE OR INPUT MODULE 1 PRESENT WINDING TEMP
117 INPUT MODULE 1 MINIMUM VALUE OR INPUT MODULE 1 MINIMUM WINDING TEMP
118 INPUT MODULE 1 MAXIMUM VALUE OR INPUT MODULE 1 MAXIMUM WINDING TEMP
119 0 OR INPUT MODULE 1 PRESENT CURRENT
120 0 OR INPUT MODULE 1 MAXIMUM CURRENT
121 INPUT MODULE 2 PRESENT VALUE OR INPUT MODULE 2 PRESENT WINDING TEMP
122 INPUT MODULE 2 MINIMUM VALUE OR INPUT MODULE 2 MINIMUM WINDING TEMP
123 INPUT MODULE 2 MAXIMUM VALUE OR INPUT MODULE 2 MAXIMUM WINDING TEMP
124 0 OR INPUT MODULE 2 PRESENT CURRENT
125 0 OR INPUT MODULE 2 MAXIMUM CURRENT
126 INPUT MODULE 3 PRESENT VALUE OR INPUT MODULE 3 PRESENT WINDING TEMP
127 INPUT MODULE 3 MINIMUM VALUE OR INPUT MODULE 3 MINIMUM WINDING TEMP
128 INPUT MODULE 3 MAXIMUM VALUE OR INPUT MODULE 3 MAXIMUM WINDING TEMP
129 0 OR INPUT MODULE 3 PRESENT CURRENT
101 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
130 0 OR INPUT MODULE 3 MAXIMUM CURRENT
131 INPUT MODULE 4 PRESENT VALUE OR INPUT MODULE 4 PRESENT WINDING TEMP
132 INPUT MODULE 4 MINIMUM VALUE OR INPUT MODULE 4 MINIMUM WINDING TEMP
133 INPUT MODULE 4 MAXIMUM VALUE OR INPUT MODULE 4 MAXIMUM WINDING TEMP
134 0 OR INPUT MODULE 4 PRESENT CURRENT
135 0 OR INPUT MODULE 4 MAXIMUM CURRENT
136 INPUT MODULE 5 PRESENT VALUE OR INPUT MODULE 5 PRESENT WINDING TEMP
137 INPUT MODULE 5 MINIMUM VALUE OR INPUT MODULE 5 MINIMUM WINDING TEMP
138 INPUT MODULE 5 MAXIMUM VALUE OR INPUT MODULE 5 MAXIMUM WINDING TEMP
139 0 OR INPUT MODULE 5 PRESENT CURRENT
140 0 OR INPUT MODULE 5 MAXIMUM CURRENT
141 INPUT MODULE 6 PRESENT VALUE OR INPUT MODULE 6 PRESENT WINDING TEMP
142 INPUT MODULE 6 MINIMUM VALUE OR INPUT MODULE 6 MINIMUM WINDING TEMP
143 INPUT MODULE 6 MAXIMUM VALUE OR INPUT MODULE 6 MAXIMUM WINDING TEMP
144 0 OR INPUT MODULE 6 PRESENT CURRENT
145 0 OR INPUT MODULE 6 MAXIMUM CURRENT
146 INPUT MODULE 7 PRESENT VALUE OR INPUT MODULE 7 PRESENT WINDING TEMP
147 INPUT MODULE 7 MINIMUM VALUE OR INPUT MODULE 7 MINIMUM WINDING TEMP
148 INPUT MODULE 7 MAXIMUM VALUE OR INPUT MODULE 7 MAXIMUM WINDING TEMP
149 0 OR INPUT MODULE 7 PRESENT CURRENT
150 0 OR INPUT MODULE 7 MAXIMUM CURRENT
151 INPUT MODULE 8 PRESENT VALUE OR INPUT MODULE 8 PRESENT WINDING TEMP
152 INPUT MODULE 8 MINIMUM VALUE OR INPUT MODULE 8 MINIMUM WINDING TEMP
153 INPUT MODULE 8 MAXIMUM VALUE OR INPUT MODULE 8 MAXIMUM WINDING TEMP
154 0 OR INPUT MODULE 8 PRESENT CURRENT
155 0 OR INPUT MODULE 8 MAXIMUM CURRENT
156 DIFFERENTIAL CALCULATION 1 PRESENT VALUE
157 DIFFERENTIAL CALCULATION 1 MINIMUM VALUE
158 DIFFERENTIAL CALCULATION 1 MAXIMUM VALUE
159 DIFFERENTIAL CALCULATION 2 PRESENT VALUE
160 DIFFERENTIAL CALCULATION 2 MINIMUM VALUE
161 DIFFERENTIAL CALCULATION 2 MAXIMUM VALUE
162 DIFFERENTIAL CALCULATION 3 PRESENT VALUE
163 DIFFERENTIAL CALCULATION 3 MINIMUM VALUE
164 DIFFERENTIAL CALCULATION 3 MAXIMUM VALUE
165 DIFFERENTIAL CALCULATION 4 PRESENT VALUE
166 DIFFERENTIAL CALCULATION 4 MINIMUM VALUE
167 DIFFERENTIAL CALCULATION 4 MAXIMUM VALUE
168 HOTTEST PRESENT WINDING TEMPERATURE OF ALL ACTIVE CT, TEMPERATURE MODULES
169 RELAY 1, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
170 RELAY 2, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
171 RELAY 3, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
172 RELAY 4, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
173 RELAY 5, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
174 RELAY 6, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
175 RELAY 7, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
102 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
176 RELAY 8, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
177 RELAY 1, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
178 RELAY 2, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
179 RELAY 3, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
180 RELAY 4, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
181 RELAY 5, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
182 RELAY 6, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
183 RELAY 7, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
184 RELAY 8, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
185 RELAY 1, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
186 RELAY 2, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
187 RELAY 3, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
188 RELAY 4, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
189 RELAY 5, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
190 RELAY 6, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
191 RELAY 7, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
192 RELAY 8, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
193 RELAY 1, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
194 RELAY 2, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
195 RELAY 3, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
196 RELAY 4, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
197 RELAY 5, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
198 RELAY 6, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
199 RELAY 7, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
200 RELAY 8, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
201 RELAY 1, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
202 RELAY 2, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
203 RELAY 3, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
204 RELAY 4, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
205 RELAY 5, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
206 RELAY 6, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
207 RELAY 7, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
208 RELAY 8, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
209 RELAY 1, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
210 RELAY 2, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
211 RELAY 3, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
212 RELAY 4, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
213 RELAY 5, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
214 RELAY 6, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
215 RELAY 7, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
216 RELAY 8, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
217 TRANSLIFE 1 CONSUMED LIFE FOR LAST HOUR CALCULATED CONSUMED LIFE FOR LAST HOUR
218 TRANSLIFE 1 CONSUMED LIFE FOR LAST DAY CALCULATED CONSUMED LIFE FOR LAST DAY
219 TRANSLIFE 1 REMAINING TRANSFORMER LIFE (20 YEARS - CONSUMED LIFE)
220 TL1 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
221 TL1 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
103 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
222 TL1 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
223 TL1 TIME TO CRITICAL SETPOINT 1 CALCULATED TIME TO 1ST SPT FOR GIVEN CONDITIONS
224 TL1 TIME TO CRITICAL SETPOINT 2 CALCULATED TIME TO 2ND SPT FOR GIVEN CONDITIONS
225 TL1 TIME TO CRITICAL SETPOINT 3 CALCULATED TIME TO 3RD SPT FOR GIVEN CONDITIONS
226 TRANSLIFE 2 CONSUMED LIFE FOR LAST HOUR CALCULATED CONSUMED LIFE FOR LAST HOUR
227 TRANSLIFE 2 CONSUMED LIFE FOR LAST DAY CALCULATED CONSUMED LIFE FOR LAST DAY
228 TRANSLIFE 2 REMAINING TRANSFORMER LIFE (20 YEARS - CONSUMED LIFE)
229 TL2 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
230 TL2 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
231 TL2 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
232 TL2 TIME TO CRITICAL SETPOINT 1 CALCULATED TIME TO 1ST SPT FOR GIVEN CONDITIONS
233 TL2 TIME TO CRITICAL SETPOINT 2 CALCULATED TIME TO 2ND SPT FOR GIVEN CONDITIONS
234 TL2 TIME TO CRITICAL SETPOINT 3 CALCULATED TIME TO 3RD SPT FOR GIVEN CONDITIONS
235 TRANSLIFE 3 CONSUMED LIFE FOR LAST HOUR CALCULATED CONSUMED LIFE FOR LAST HOUR
236 TRANSLIFE 3 CONSUMED LIFE FOR LAST DAY CALCULATED CONSUMED LIFE FOR LAST DAY
237 TRANSLIFE 3 REMAINING TRANSFORMER LIFE (20 YEARS - CONSUMED LIFE)
238 TL3 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
239 TL3 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
240 TL3 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
241 TL3 TIME TO CRITICAL SETPOINT 1 CALCULATED TIME TO 1ST SPT FOR GIVEN CONDITIONS
242 TL3 TIME TO CRITICAL SETPOINT 2 CALCULATED TIME TO 2ND SPT FOR GIVEN CONDITIONS
243 TL3 TIME TO CRITICAL SETPOINT 3 CALCULATED TIME TO 3RD SPT FOR GIVEN CONDITIONS
244 COOLING BANK 1 PRESENT RUNNING CURRENT COOLING BANK 1 PRESENT/STEADY STATE CURRENT
245 COOLING BANK 1 MINIMUM RUNNING CURRENT COOLING BANK 1 MINIMUM STEADY STATE CURRENT
246 COOLING BANK 1 MAXIMUM RUNNING CURRENT COOLING BANK 1 MAXIMUM STEADY STATE CURRENT
247 CB1 RUNNING CURRENT UPPER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
248 CB1 RUNNING CURRENT LOWER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
249 CB1 PRESENT PEAK INRUSH CURRENT VALUE COOLING BANK 1 PRESENT PEAK INRUSH CURRENT
250 CB1 MINIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 1 MINIMUM PEAK INRUSH CURRENT
251 CB1 MAXIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 1 MAXIMUM PEAK INRUSH CURRENT
252 CB1 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
253 CB1 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
254 COOLING BANK 2 PRESENT RUNNING CURRENT COOLING BANK 2 PRESENT/STEADY STATE CURRENT
255 COOLING BANK 2 MINIMUM RUNNING CURRENT COOLING BANK 2 MINIMUM STEADY STATE CURRENT
256 COOLING BANK 2 MAXIMUM RUNNING CURRENT COOLING BANK 2 MAXIMUM STEADY STATE CURRENT
257 CB2 RUNNING CURRENT UPPER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
258 CB2 RUNNING CURRENT LOWER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
259 CB2 PRESENT PEAK INRUSH CURRENT VALUE COOLING BANK 2 PRESENT PEAK INRUSH CURRENT
260 CB2 MINIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 2 MINIMUM PEAK INRUSH CURRENT
261 CB2 MAXIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 2 MAXIMUM PEAK INRUSH CURRENT
262 CB2 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
263 CB2 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
264 COOLING BANK 3 PRESENT RUNNING CURRENT COOLING BANK 3 PRESENT/STEADY STATE CURRENT
265 COOLING BANK 3 MINIMUM RUNNING CURRENT COOLING BANK 3 MINIMUM STEADY STATE CURRENT
266 COOLING BANK 3 MAXIMUM RUNNING CURRENT COOLING BANK 3 MAXIMUM STEADY STATE CURRENT
267 CB3 RUNNING CURRENT UPPER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
104 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
268 CB3 RUNNING CURRENT LOWER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
269 CB3 PRESENT PEAK INRUSH CURRENT VALUE COOLING BANK 3 PRESENT PEAK INRUSH CURRENT
270 CB3 MINIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 3 MINIMUM PEAK INRUSH CURRENT
271 CB3 MAXIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 3 MAXIMUM PEAK INRUSH CURRENT
272 CB3 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
273 CB3 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
274 COOLING BANK 4 PRESENT RUNNING CURRENT COOLING BANK 4 PRESENT/STEADY STATE CURRENT
275 COOLING BANK 4 MINIMUM RUNNING CURRENT COOLING BANK 4 MINIMUM STEADY STATE CURRENT
276 COOLING BANK 4 MAXIMUM RUNNING CURRENT COOLING BANK 4 MAXIMUM STEADY STATE CURRENT
277 CB4 RUNNING CURRENT UPPER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
278 CB4 RUNNING CURRENT LOWER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
279 CB4 PRESENT PEAK INRUSH CURRENT VALUE COOLING BANK 4 PRESENT PEAK INRUSH CURRENT
280 CB4 MINIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 4 MINIMUM PEAK INRUSH CURRENT
281 CB4 MAXIMUM PEAK INRUSH CURRENT VALUE COOLING BANK 4 MAXIMUM PEAK INRUSH CURRENT
282 CB4 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
283 CB4 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
284 TAP POSITION -16 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-16)
285 TAP POSITION -15 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-15)
286 TAP POSITION -14 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-14)
287 TAP POSITION -13 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-13)
288 TAP POSITION -12 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-12)
289 TAP POSITION -11 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-11)
290 TAP POSITION -10 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-10)
291 TAP POSITION -9 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-9)
292 TAP POSITION -8 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-8)
293 TAP POSITION -7 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-7)
294 TAP POSITION -6 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-6)
295 TAP POSITION -5 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-5)
296 TAP POSITION -4 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-4)
297 TAP POSITION -3 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-3)
298 TAP POSITION -2 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-2)
299 TAP POSITION -1 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (-1)
300 TAP POSITION +0 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+0)
301 TAP POSITION +1 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+1)
302 TAP POSITION +2 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+2)
303 TAP POSITION +3 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+3)
304 TAP POSITION +4 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+4)
305 TAP POSITION +5 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+5)
306 TAP POSITION +6 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+6)
307 TAP POSITION +7 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+7)
308 TAP POSITION +8 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+8)
309 TAP POSITION +9 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+9)
310 TAP POSITION +10 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+10)
311 TAP POSITION +11 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+11)
312 TAP POSITION +12 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+12)
313 TAP POSITION +13 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+13)
105 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
314 TAP POSITION +14 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+14)
315 TAP POSITION +15 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+15)
316 TAP POSITION +16 AVERAGE MAKE CURRENT AVERAGE MAKE CURRENT FOR TAP POSITION (+16)
317 TAP POSITION -16 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-16)
318 TAP POSITION -15 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-15)
319 TAP POSITION -14 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-14)
320 TAP POSITION -13 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-13)
321 TAP POSITION -12 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-12)
322 TAP POSITION -11 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-11)
323 TAP POSITION -10 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-10)
324 TAP POSITION -9 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-9)
325 TAP POSITION -8 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-8)
326 TAP POSITION -7 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-7)
327 TAP POSITION -6 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-6)
328 TAP POSITION -5 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-5)
329 TAP POSITION -4 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-4)
330 TAP POSITION -3 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-3)
331 TAP POSITION -2 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-2)
332 TAP POSITION -1 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (-1)
333 TAP POSITION +0 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+0)
334 TAP POSITION +1 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+1)
335 TAP POSITION +2 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+2)
336 TAP POSITION +3 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+3)
337 TAP POSITION +4 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+4)
338 TAP POSITION +5 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+5)
339 TAP POSITION +6 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+6)
340 TAP POSITION +7 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+7)
341 TAP POSITION +8 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+8)
342 TAP POSITION +9 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+9)
343 TAP POSITION +10 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+10)
344 TAP POSITION +11 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+11)
345 TAP POSITION +12 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+12)
346 TAP POSITION +13 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+13)
347 TAP POSITION +14 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+14)
348 TAP POSITION +15 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+15)
349 TAP POSITION +16 AVERAGE BREAK CURRENT AVERAGE BREAK CURRENT FOR TAP POSITION (+16)
350 LTC HI-ALARM RUN CURRENT UPPER SETPOINT LTC HIGH-PRIORITY STEADY STATE UPPER SETPOINT
351 LTC LO-ALARM RUN CURRENT UPPER SETPOINT LTC LOW-PRIORITY STEADY STATE UPPER SETPOINT
352 LTC HI-ALARM RUN CURRENT LOWER SETPOINT LTC HIGH-PRIORITY STEADY STATE LOWER SETPOINT
353 LTC LO-ALARM RUN CURRENT LOWER SETPOINT LTC LOW-PRIORITY STEADY STATE LOWER SETPOINT
LTC HI-ALARM INRUSH CURRENT UPPER
354 SETPOINT LTC HIGH-PRIORITY INRUSH CURRENT UPPER SETPOINT
LTC LO-ALARM INRUSH CURRENT UPPER
355 SETPOINT LTC LOW-PRIORITY INRUSH CURRENT UPPER SETPOINT
LTC HI-ALARM INRUSH CURRENT LOWER
356 SETPOINT LTC HIGH-PRIORITY INRUSH CURRENT LOWER SETPOINT
LTC LO-ALARM INRUSH CURRENT LOWER
357 SETPOINT LTC LOW-PRIORITY INRUSH CURRENT LOWER SETPOINT
106 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
358 MOD 1; FIBER PROBE 1 PRESENT TEMPERATURE HOT SPOT MODULE 1; 1ST PROBE PRESENT TEMP
359 MOD 1; FIBER PROBE 1 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 1ST PROBE MINIMUM TEMP
360 MOD 1; FIBER PROBE 1 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 1ST PROBE MAXIMUM TEMP
361 MOD 1; FIBER PROBE 2 PRESENT TEMPERATURE HOT SPOT MODULE 1; 2ND PROBE PRESENT TEMP
362 MOD 1; FIBER PROBE 2 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 2ND PROBE MINIMUM TEMP
363 MOD 1; FIBER PROBE 2 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 2ND PROBE MAXIMUM TEMP
364 MOD 1; FIBER PROBE 3 PRESENT TEMPERATURE HOT SPOT MODULE 1; 3RD PROBE PRESENT TEMP
365 MOD 1; FIBER PROBE 3 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 3RD PROBE MINIMUM TEMP
366 MOD 1; FIBER PROBE 3 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 3RD PROBE MAXIMUM TEMP
367 MOD 1; FIBER PROBE 4 PRESENT TEMPERATURE HOT SPOT MODULE 1; 4TH PROBE PRESENT TEMP
368 MOD 1; FIBER PROBE 4 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 4TH PROBE MINIMUM TEMP
369 MOD 1; FIBER PROBE 4 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 4TH PROBE MAXIMUM TEMP
370 MOD 1; FIBER PROBE 5 PRESENT TEMPERATURE HOT SPOT MODULE 1; 5TH PROBE PRESENT TEMP
371 MOD 1; FIBER PROBE 5 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 5TH PROBE MINIMUM TEMP
372 MOD 1; FIBER PROBE 5 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 5TH PROBE MAXIMUM TEMP
373 MOD 1; FIBER PROBE 6 PRESENT TEMPERATURE HOT SPOT MODULE 1; 6TH PROBE PRESENT TEMP
374 MOD 1; FIBER PROBE 6 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 6TH PROBE MINIMUM TEMP
375 MOD 1; FIBER PROBE 6 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 6TH PROBE MAXIMUM TEMP
376 MOD 1; FIBER PROBE 7 PRESENT TEMPERATURE HOT SPOT MODULE 1; 6TH PROBE PRESENT TEMP
377 MOD 1; FIBER PROBE 7 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 7TH PROBE MINIMUM TEMP
378 MOD 1; FIBER PROBE 7 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 7TH PROBE MAXIMUM TEMP
379 MOD 1; FIBER PROBE 8 PRESENT TEMPERATURE HOT SPOT MODULE 1; 8TH PROBE PRESENT TEMP
380 MOD 1; FIBER PROBE 8 MINIMUM TEMPERATURE HOT SPOT MODULE 1; 8TH PROBE MINIMUM TEMP
381 MOD 1; FIBER PROBE 8 MAXIMUM TEMPERATURE HOT SPOT MODULE 1; 8TH PROBE MAXIMUM TEMP
382 MOD 2; FIBER PROBE 1 PRESENT TEMPERATURE HOT SPOT MODULE 2; 1ST PROBE PRESENT TEMP
383 MOD 2; FIBER PROBE 1 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 1ST PROBE MINIMUM TEMP
384 MOD 2; FIBER PROBE 1 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 1ST PROBE MAXIMUM TEMP
385 MOD 2; FIBER PROBE 2 PRESENT TEMPERATURE HOT SPOT MODULE 2; 2ND PROBE PRESENT TEMP
386 MOD 2; FIBER PROBE 2 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 2ND PROBE MINIMUM TEMP
387 MOD 2; FIBER PROBE 2 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 2ND PROBE MAXIMUM TEMP
388 MOD 2; FIBER PROBE 3 PRESENT TEMPERATURE HOT SPOT MODULE 2; 3RD PROBE PRESENT TEMP
389 MOD 2; FIBER PROBE 3 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 3RD PROBE MINIMUM TEMP
390 MOD 2; FIBER PROBE 3 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 3RD PROBE MAXIMUM TEMP
391 MOD 2; FIBER PROBE 4 PRESENT TEMPERATURE HOT SPOT MODULE 2; 4TH PROBE PRESENT TEMP
392 MOD 2; FIBER PROBE 4 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 4TH PROBE MINIMUM TEMP
393 MOD 2; FIBER PROBE 4 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 4TH PROBE MAXIMUM TEMP
394 MOD 2; FIBER PROBE 5 PRESENT TEMPERATURE HOT SPOT MODULE 2; 5TH PROBE PRESENT TEMP
395 MOD 2; FIBER PROBE 5 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 5TH PROBE MINIMUM TEMP
396 MOD 2; FIBER PROBE 5 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 5TH PROBE MAXIMUM TEMP
397 MOD 2; FIBER PROBE 6 PRESENT TEMPERATURE HOT SPOT MODULE 2; 6TH PROBE PRESENT TEMP
398 MOD 2; FIBER PROBE 6 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 6TH PROBE MINIMUM TEMP
399 MOD 2; FIBER PROBE 6 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 6TH PROBE MAXIMUM TEMP
400 MOD 2; FIBER PROBE 7 PRESENT TEMPERATURE HOT SPOT MODULE 2; 6TH PROBE PRESENT TEMP
401 MOD 2; FIBER PROBE 7 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 7TH PROBE MINIMUM TEMP
402 MOD 2; FIBER PROBE 7 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 7TH PROBE MAXIMUM TEMP
403 MOD 2; FIBER PROBE 8 PRESENT TEMPERATURE HOT SPOT MODULE 2; 8TH PROBE PRESENT TEMP
107 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
404 MOD 2; FIBER PROBE 8 MINIMUM TEMPERATURE HOT SPOT MODULE 2; 8TH PROBE MINIMUM TEMP
405 MOD 2; FIBER PROBE 8 MAXIMUM TEMPERATURE HOT SPOT MODULE 2; 8TH PROBE MAXIMUM TEMP
406 LIFE CONSUMPTION UNITY TEMPERATURE TEMP WHERE CONSUMED LIFE EQUALS OPERATING LIFE
LTC HI-ALARM TOTAL TAP COUNT SETPOINT
407 VALUE LTC HIGH-PRIORITY TOTAL TAP COUNT SETPOINT
LTC LO-ALARM TOTAL TAP COUNT SETPOINT
408 VALUE LTC LOW-PRIORITY TOTAL TAP COUNT SETPOINT
LTC HI-ALARM MOTOR ACTUATION SETPOINT
409 VALUE LTC HIGH-PRIORITY MOTOR ACTUATION COUNT SPT
LTC LO-ALARM MOTOR ACTUATION SETPOINT
410 VALUE LTC LOW-PRIORITY MOTOR ACTUATION COUNT SPT
411 LTC TAP PERIOD TIME PERIOD TO MEASURE LTC TAP COUNTS
412 LTC PRESENT COUNTS TOTAL COUNTS IN PRESENT TAP PERIOD
413 LTC PREVIOUS COUNTS TOTAL COUNTS IN THE PREVIOUS TAP PERIOD
TRANSLIFE 1; TEMPERATURE PROFILE, 1ST
414 RANGE TOTAL WINDING TEMP TIME IN LOWEST TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 2ND
415 RANGE TOTAL WINDING TEMP TIME IN 2ND TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 3RD
416 RANGE TOTAL WINDING TEMP TIME IN 3RD TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 4TH
417 RANGE TOTAL WINDING TEMP TIME IN 4TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 5TH
418 RANGE TOTAL WINDING TEMP TIME IN 5TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 6TH
419 RANGE TOTAL WINDING TEMP TIME IN 6TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 7TH
420 RANGE TOTAL WINDING TEMP TIME IN 7TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 8TH
421 RANGE TOTAL WINDING TEMP TIME IN 8TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 9TH
422 RANGE TOTAL WINDING TEMP TIME IN 9TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 10TH
423 RANGE TOTAL WINDING TEMP TIME IN 10TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 11TH
424 RANGE TOTAL WINDING TEMP TIME IN 11TH TEMP RANGE
TRANSLIFE 1; TEMPERATURE PROFILE, 12TH
425 RANGE TOTAL WINDING TEMP TIME IN HIGHEST TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 1ST
426 RANGE TOTAL WINDING TEMP TIME IN LOWEST TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 2ND
427 RANGE TOTAL WINDING TEMP TIME IN 2ND TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 3RD
428 RANGE TOTAL WINDING TEMP TIME IN 3RD TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 4TH
429 RANGE TOTAL WINDING TEMP TIME IN 4TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 5TH
430 RANGE TOTAL WINDING TEMP TIME IN 5TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 6TH
431 RANGE TOTAL WINDING TEMP TIME IN 6TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 7TH
432 RANGE TOTAL WINDING TEMP TIME IN 7TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 8TH
433 RANGE TOTAL WINDING TEMP TIME IN 8TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 9TH
434 RANGE TOTAL WINDING TEMP TIME IN 9TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 10TH
435 RANGE TOTAL WINDING TEMP TIME IN 10TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 11TH
436 RANGE TOTAL WINDING TEMP TIME IN 11TH TEMP RANGE
TRANSLIFE 2; TEMPERATURE PROFILE, 12TH
437 RANGE TOTAL WINDING TEMP TIME IN HIGHEST TEMP RANGE
108 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
TRANSLIFE 3; TEMPERATURE PROFILE, 1ST
438 RANGE TOTAL WINDING TEMP TIME IN LOWEST TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 2ND
439 RANGE TOTAL WINDING TEMP TIME IN 2ND TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 3RD
440 RANGE TOTAL WINDING TEMP TIME IN 3RD TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 4TH
441 RANGE TOTAL WINDING TEMP TIME IN 4TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 5TH
442 RANGE TOTAL WINDING TEMP TIME IN 5TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 6TH
443 RANGE TOTAL WINDING TEMP TIME IN 6TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 7TH
444 RANGE TOTAL WINDING TEMP TIME IN 7TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 8TH
445 RANGE TOTAL WINDING TEMP TIME IN 8TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 9TH
446 RANGE TOTAL WINDING TEMP TIME IN 9TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 10TH
447 RANGE TOTAL WINDING TEMP TIME IN 10TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 11TH
448 RANGE TOTAL WINDING TEMP TIME IN 11TH TEMP RANGE
TRANSLIFE 3; TEMPERATURE PROFILE, 12TH
449 RANGE TOTAL WINDING TEMP TIME IN HIGHEST TEMP RANGE
450 COOLING BANK 1 TOTAL ACTUATION COUNTS TOTAL # OF TIMES THE COOLING FANS HAVE ENGAGED
451 COOLING BANK 1 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
452 COOLING BANK 1 TOTAL SYSTEM RUN TIME TOTAL # OF HOURS THAT THE FANS HAVE BEEN ON
453 COOLING BANK 1 RUN TIME SETPOINT VALUE TOTAL RUN TIME SETPOINT
454 COOLING BANK 2 TOTAL ACTUATION COUNTS TOTAL # OF TIMES THE COOLING FANS HAVE ENGAGED
455 COOLING BANK 2 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
456 COOLING BANK 2 TOTAL SYSTEM RUN TIME TOTAL # OF HOURS THAT THE FANS HAVE BEEN ON
457 COOLING BANK 2 RUN TIME SETPOINT VALUE TOTAL RUN TIME SETPOINT
458 COOLING BANK 3 TOTAL ACTUATION COUNTS TOTAL # OF TIMES THE COOLING FANS HAVE ENGAGED
459 COOLING BANK 3 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
460 COOLING BANK 3 TOTAL SYSTEM RUN TIME TOTAL # OF HOURS THAT THE FANS HAVE BEEN ON
461 COOLING BANK 3 RUN TIME SETPOINT VALUE TOTAL RUN TIME SETPOINT
462 COOLING BANK 4 TOTAL ACTUATION COUNTS TOTAL # OF TIMES THE COOLING FANS HAVE ENGAGED
463 COOLING BANK 4 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
464 COOLING BANK 4 TOTAL SYSTEM RUN TIME TOTAL # OF HOURS THAT THE FANS HAVE BEEN ON
465 COOLING BANK 4 RUN TIME SETPOINT VALUE TOTAL RUN TIME SETPOINT
466 LTC, TAP POSITION -16 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-16)
467 LTC, TAP POSITION -15 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-15)
468 LTC, TAP POSITION -14 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-14)
469 LTC, TAP POSITION -13 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-13)
470 LTC, TAP POSITION -12 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-12)
471 LTC, TAP POSITION -11 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-11)
472 LTC, TAP POSITION -10 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-10)
473 LTC, TAP POSITION -9 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-9)
474 LTC, TAP POSITION -8 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-8)
475 LTC, TAP POSITION -7 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-7)
476 LTC, TAP POSITION -6 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-6)
477 LTC, TAP POSITION -5 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-5)
478 LTC, TAP POSITION -4 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-4)
109 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
479 LTC, TAP POSITION -3 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-3)
480 LTC, TAP POSITION -2 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-2)
481 LTC, TAP POSITION -1 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (-1)
482 LTC, TAP POSITION +0 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+0)
483 LTC, TAP POSITION +1 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+1)
484 LTC, TAP POSITION +2 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+2)
485 LTC, TAP POSITION +3 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+3)
486 LTC, TAP POSITION +4 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+4)
487 LTC, TAP POSITION +5 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+5)
488 LTC, TAP POSITION +6 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+6)
489 LTC, TAP POSITION +7 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+7)
490 LTC, TAP POSITION +8 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+8)
491 LTC, TAP POSITION +9 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+9)
492 LTC, TAP POSITION +10 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+10)
493 LTC, TAP POSITION +11 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+11)
494 LTC, TAP POSITION +12 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+12)
495 LTC, TAP POSITION +13 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+13)
496 LTC, TAP POSITION +14 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+14)
497 LTC, TAP POSITION +15 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+15)
498 LTC, TAP POSITION +16 TOTAL TAP COUNTS TOTAL TAP COUNTS FOR TAP POSITION (+16)
499 LTC, TAP POSITION -16 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-16)
500 LTC, TAP POSITION -15 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-15)
501 LTC, TAP POSITION -14 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-14)
502 LTC, TAP POSITION -13 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-13)
503 LTC, TAP POSITION -12 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-12)
504 LTC, TAP POSITION -11 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-11)
505 LTC, TAP POSITION -10 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-10)
506 LTC, TAP POSITION -9 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-9)
507 LTC, TAP POSITION -8 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-8)
508 LTC, TAP POSITION -7 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-7)
509 LTC, TAP POSITION -6 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-6)
510 LTC, TAP POSITION -5 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-5)
511 LTC, TAP POSITION -4 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-4)
512 LTC, TAP POSITION -3 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-3)
513 LTC, TAP POSITION -2 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-2)
514 LTC, TAP POSITION -1 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (-1)
515 LTC, TAP POSITION +0 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+0)
516 LTC, TAP POSITION +1 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+1)
517 LTC, TAP POSITION +2 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+2)
518 LTC, TAP POSITION +3 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+3)
519 LTC, TAP POSITION +4 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+4)
520 LTC, TAP POSITION +5 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+5)
521 LTC, TAP POSITION +6 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+6)
522 LTC, TAP POSITION +7 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+7)
523 LTC, TAP POSITION +8 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+8)
524 LTC, TAP POSITION +9 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+9)
110 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
525 LTC, TAP POSITION +10 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+10)
526 LTC, TAP POSITION +11 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+11)
527 LTC, TAP POSITION +12 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+12)
528 LTC, TAP POSITION +13 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+13)
529 LTC, TAP POSITION +14 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+14)
530 LTC, TAP POSITION +15 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+15)
531 LTC, TAP POSITION +16 TOTAL RUN TIME TOTAL RUN TIME FOR TAP POSITION (+16)
532 LTC, TOTAL MOTOR ACTUATION COUNTS TOTAL NUMBER OF MOTOR ACTUATION COUNTS
533 FIRMWARE REVISION FOR THIS 509ITM UNIT
534 INSTALLED DIGITAL SENSORS
535 SYSTEM DATE YEAR VALUE
536 SYSTEM DATE MONTH VALUE
537 SYSTEM DATE DAY VALUE
538 SYSTEM TIME HOUR VALUE
539 SYSTEM TIME MINUTE VALUE
540 SYSTEM TIME SECOND VALUE
541 TOTAL PHYSICAL NUMBER OF TAPS # OF TAPS IN LTC; E.G. 33, 17, 9
542 AMBIENT TEMPERATURE MODULE NUMBER
543 TRANSLIFE LIFE CONSUMPTION 'A' VARIABLE
544 TRANSLIFE LIFE CONSUMPTION 'B' VARIABLE
545 COOLING EXERCISER RUN TIME MINUTES FAN EXERCISER WILL RUN WHEN ACTIVE
546 COOLING EXERCISER CYCLE TIME DAYS BETWEEN EXERCISER RUN TIME BEING ACTIVE
547 COOLING EXERCISER START TIME HOUR TO BEGIN FAN EXERCISER IN MILITARY TIME
548 STARTING MONTH FOR SEASONAL SETPOINT RELAY FEATURE (1 - 12)
549 STARTING DAY FOR SEASONAL SETPOINT RELAY FEATURE (1 - 31)
550 ENDING MONTH FOR SEASONAL SETPOINT RELAY FEATURE (1 - 12)
551 ENDING DAY FOR SEASONAL SETPOINT RELAY FEATURE (1 - 31)
552 AMBIENT TEMPERATURE FORECAST SETPOINT RELAY FEATURE
553 AMBIENT TEMPERATURE THRESHOLD HOURS # OF HOURS TO EXCEED SETPOINT TO BECOME ACTIVE
ROLLING PERIOD IN HOURS TO MEASURE THRESHOLD
554 AMBIENT TEMPERATURE MEASUREMENT PERIOD TEMP
555 MODULE # MEASURING AMBIENT TEMPERATURE MODULE # IF THERE IS AN AMBIENT SENSOR
556 COOLING BANK 1 AVERAGE RUNNING CURRENT CB1 AVERAGE STEADY STATE CURRENT VALUE
557 COOLING BANK 1 AVERAGE INRUSH CURRENT CB1 AVERAGE INRUSH CURRENT VALUE
558 COOLING BANK 1 DIFFERENTIAL SETPOINT CB1 DIFFERENTIAL SETPOINT VALUE
559 COOLING BANK 1 DIFFERENTIAL HYSTERESIS CB1 DIFFERENTIAL HYSTERESIS VALUE
560 COOLING BANK 2 AVERAGE RUNNING CURRENT CB2 AVERAGE STEADY STATE CURRENT VALUE
561 COOLING BANK 2 AVERAGE INRUSH CURRENT CB2 AVERAGE INRUSH CURRENT VALUE
562 COOLING BANK 2 DIFFERENTIAL SETPOINT CB2 DIFFERENTIAL SETPOINT VALUE
563 COOLING BANK 2 DIFFERENTIAL HYSTERESIS CB2 DIFFERENTIAL HYSTERESIS VALUE
564 COOLING BANK 3 AVERAGE RUNNING CURRENT CB3 AVERAGE STEADY STATE CURRENT VALUE
565 COOLING BANK 3 AVERAGE INRUSH CURRENT CB3 AVERAGE INRUSH CURRENT VALUE
566 COOLING BANK 3 DIFFERENTIAL SETPOINT CB3 DIFFERENTIAL SETPOINT VALUE
567 COOLING BANK 3 DIFFERENTIAL HYSTERESIS CB3 DIFFERENTIAL HYSTERESIS VALUE
568 COOLING BANK 4 AVERAGE RUNNING CURRENT CB4 AVERAGE STEADY STATE CURRENT VALUE
569 COOLING BANK 4 AVERAGE INRUSH CURRENT CB4 AVERAGE INRUSH CURRENT VALUE
111 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
570 COOLING BANK 4 DIFFERENTIAL SETPOINT CB4 DIFFERENTIAL SETPOINT VALUE
571 COOLING BANK 4 DIFFERENTIAL HYSTERESIS CB4 DIFFERENTIAL HYSTERESIS VALUE
572 CURRENT LOOP 1 CONTROL SIGNAL VALUE OF SIGNAL CONTROLLING LOOP 1
573 CURRENT LOOP 2 CONTROL SIGNAL VALUE OF SIGNAL CONTROLLING LOOP 2
574 CURRENT LOOP 3 CONTROL SIGNAL VALUE OF SIGNAL CONTROLLING LOOP 3
575 CURRENT LOOP 4 CONTROL SIGNAL VALUE OF SIGNAL CONTROLLING LOOP 4
576 CURRENT LOOP 1 MINIMUM SCALING RANGE MINIMUM SCALING VALUE FOR CURRENT LOOP 1
577 CURRENT LOOP 2 MINIMUM SCALING RANGE MINIMUM SCALING VALUE FOR CURRENT LOOP 2
578 CURRENT LOOP 3 MINIMUM SCALING RANGE MINIMUM SCALING VALUE FOR CURRENT LOOP 3
579 CURRENT LOOP 4 MINIMUM SCALING RANGE MINIMUM SCALING VALUE FOR CURRENT LOOP 4
580 CURRENT LOOP 1 MAXIMUM SCALING RANGE MAXIMUM SCALING VALUE FOR CURRENT LOOP 1
581 CURRENT LOOP 2 MAXIMUM SCALING RANGE MAXIMUM SCALING VALUE FOR CURRENT LOOP 2
582 CURRENT LOOP 3 MAXIMUM SCALING RANGE MAXIMUM SCALING VALUE FOR CURRENT LOOP 3
583 CURRENT LOOP 4 MAXIMUM SCALING RANGE MAXIMUM SCALING VALUE FOR CURRENT LOOP 4
584 RELAY 1 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
585 RELAY 2 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
586 RELAY 3 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
587 RELAY 4 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
588 RELAY51 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
589 RELAY 6 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
590 RELAY 7 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
591 RELAY 8 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
592 RELAY 1 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
593 RELAY 2 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
594 RELAY 3 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
595 RELAY 4 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
596 RELAY 5 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
597 RELAY 6 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
598 RELAY 7 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
599 RELAY 8 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
600 RELAY 1 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
601 RELAY 2 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
602 RELAY 3 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
603 RELAY 4 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
604 RELAY 5 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
605 RELAY 6 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
606 RELAY 7 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
607 RELAY 8 ACTUATION DELAY - HOURS VALUE ACTUATION DELAY - HOURS
608 RELAY 1 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
609 RELAY 2 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
610 RELAY 3 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
611 RELAY 4 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
612 RELAY 5 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
613 RELAY 6 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
614 RELAY 7 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
615 RELAY 8 ACTUATION DELAY - MINUTES VALUE ACTUATION DELAY - MINUTES
112 www.qualitrolcorp.com
Protocol Manual
ANALOG INPUT
I/O
ADD DATA VARIABLE DESCRIPTION
616 RELAY 1 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
617 RELAY 2 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
618 RELAY 3 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
619 RELAY 4 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
620 RELAY 5 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
621 RELAY 6 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
622 RELAY 7 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
623 RELAY 8 ACTUATION DELAY - SECONDS VALUE ACTUATION DELAY - SECONDS
624 LTC PREVIOUS MOTOR RUN CURRENT MOTOR RUN CURRENT FROM LAST ACTUATION
625 LTC PREVIOUS MOTOR INRUSH CURRENT MOTOR INRUSH CURRENT FROM LAST ACTUATION
626 LTC PREVIOUS MOTOR RUN TIME MOTOR ACTUATION TIME FROM LAST ACTUATION
627 LTC HI-ALARM DIFFERENTIAL SETPOINT VALUE DIFFERENTIAL SETPOINT VALUE FOR HI-ALARM
628 LTC HI-ALARM DIFFERENTIAL HYSTERSIS VALUE DIFFERENTIAL HYSTERESIS VALUE FOR HI-ALARM
629 LTC LO-ALARM DIFFERENTIAL SETPOINT VALUE DIFFERENTIAL SETPOINT VALUE FOR LO-ALARM
630 LTC LO-ALARM DIFFERENTIAL HYSTERSIS VALUE DIFFERENTIAL HYSTERESIS VALUE FOR LO-ALARM
631 LTC HI-ALARM MOTOR RUN TIME SETPOINT MOTOR RUN TIME SETPOINT FOR HI-ALARM
632 LTC LO-ALARM MOTOR RUN TIME SETPOINT MOTOR RUN TIME SETPOINT FOR LO-ALARM
ANALOG OUTPUTS
I/O
ADD DATA VARIABLE DESCRIPTION
700 RELAY 1, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
701 RELAY 2, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
702 RELAY 3, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
703 RELAY 4, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
704 RELAY 5, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
705 RELAY 6, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
706 RELAY 7, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
707 RELAY 8, SETPOINT 1 VALUE SETPOINT IN THE 1ST COLUMN OF THE MATRIX
708 RELAY 1, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
709 RELAY 2, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
710 RELAY 3, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
711 RELAY 4, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
712 RELAY 5, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
713 RELAY 6, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
714 RELAY 7, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
715 RELAY 8, HYSTERESIS 1 VALUE HYSTERESIS IN THE 1ST COLUMN OF THE MATRIX
716 RELAY 1, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
717 RELAY 2, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
718 RELAY 3, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
719 RELAY 4, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
720 RELAY 5, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
721 RELAY 6, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
722 RELAY 7, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
723 RELAY 8, SETPOINT 2 VALUE SETPOINT IN THE 2ND COLUMN OF THE MATRIX
724 RELAY 1, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
113 www.qualitrolcorp.com
Protocol Manual
ANALOG OUTPUTS
I/O
ADD DATA VARIABLE DESCRIPTION
725 RELAY 2, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
726 RELAY 3, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
727 RELAY 4, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
728 RELAY 5, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
729 RELAY 6, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
730 RELAY 7, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
731 RELAY 8, HYSTERESIS 2 VALUE HYSTERESIS IN THE 2ND COLUMN OF THE MATRIX
732 RELAY 1, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
733 RELAY 2, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
734 RELAY 3, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
735 RELAY 4, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
736 RELAY 5, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
737 RELAY 6, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
738 RELAY 7, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
739 RELAY 8, SETPOINT 3 VALUE SETPOINT IN THE 3RD COLUMN OF THE MATRIX
740 RELAY 1, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
741 RELAY 2, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
742 RELAY 3, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
743 RELAY 4, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
744 RELAY 5, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
745 RELAY 6, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
746 RELAY 7, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
747 RELAY 8, HYSTERESIS 3 VALUE HYSTERESIS IN THE 3RD COLUMN OF THE MATRIX
748 RELAY 1, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
749 RELAY 2, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
750 RELAY 3, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
751 RELAY 4, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
752 RELAY 5, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
753 RELAY 6, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
754 RELAY 7, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
755 RELAY 8, SETPOINT 4 VALUE SETPOINT IN THE 4TH COLUMN OF THE MATRIX
756 RELAY 1, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
757 RELAY 2, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
758 RELAY 3, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
759 RELAY 4, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
760 RELAY 5, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
761 RELAY 6, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
762 RELAY 7, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
763 RELAY 8, HYSTERESIS 4 VALUE HYSTERESIS IN THE 4TH COLUMN OF THE MATRIX
764 TL1 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
765 TL1 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
766 TL1 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
767 TL2 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
768 TL2 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
769 TL2 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
770 TL3 CRITICAL WINDING TEMP SETPOINT 1 1ST CRITICAL SPT TO CALCULATE TIME TO REACH
114 www.qualitrolcorp.com
Protocol Manual
ANALOG OUTPUTS
I/O
ADD DATA VARIABLE DESCRIPTION
771 TL3 CRITICAL WINDING TEMP SETPOINT 2 2ND CRITICAL SPT TO CALCULATE TIME TO REACH
772 TL3 CRITICAL WINDING TEMP SETPOINT 3 3RD CRITICAL SPT TO CALCULATE TIME TO REACH
773 CB1 RUNNING CURRENT UPPER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
774 CB1 RUNNING CURRENT LOWER SETPOINT COOLING BANK 1 STEADY STATE CURRENT SETPOINT
775 CB1 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
776 CB1 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 1 PEAK INRUSH CURRENT SETPOINT
777 COOLING BANK 1 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
778 COOLING BANK 1 RUN TIME SETPOINT VALUE COOLING BANK 1 TOTAL RUN TIME SETPOINT
779 CB2 RUNNING CURRENT UPPER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
780 CB2 RUNNING CURRENT LOWER SETPOINT COOLING BANK 2 STEADY STATE CURRENT SETPOINT
781 CB2 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
782 CB2 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 2 PEAK INRUSH CURRENT SETPOINT
783 COOLING BANK 2 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
784 COOLING BANK 2 RUN TIME SETPOINT VALUE COOLING BANK 2 TOTAL RUN TIME SETPOINT
785 CB3 RUNNING CURRENT UPPER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
786 CB3 RUNNING CURRENT LOWER SETPOINT COOLING BANK 3 STEADY STATE CURRENT SETPOINT
787 CB3 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
788 CB3 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 3 PEAK INRUSH CURRENT SETPOINT
789 COOLING BANK 3 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
790 COOLING BANK 3 RUN TIME SETPOINT VALUE COOLING BANK 3 TOTAL RUN TIME SETPOINT
791 CB4 RUNNING CURRENT UPPER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
792 CB4 RUNNING CURRENT LOWER SETPOINT COOLING BANK 4 STEADY STATE CURRENT SETPOINT
793 CB4 INRUSH CURRENT UPPER SETPOINT VALUE COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
794 CB4 INRUSH CURRENT LOWER SETPOINT VALUE COOLING BANK 4 PEAK INRUSH CURRENT SETPOINT
795 COOLING BANK 4 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
796 COOLING BANK 4 RUN TIME SETPOINT VALUE COOLING BANK 4 TOTAL RUN TIME SETPOINT
797 LTC HI-ALARM RUN CURRENT UPPER SETPOINT LTC HIGH-PRIORITY STEADY STATE UPPER SETPOINT
798 LTC LO-ALARM RUN CURRENT UPPER SETPOINT LTC LOW-PRIORITY STEADY STATE UPPER SETPOINT
799 LTC HI-ALARM RUN CURRENT LOWER SETPOINT LTC HIGH-PRIORITY STEADY STATE LOWER SETPOINT
800 LTC LO-ALARM RUN CURRENT LOWER SETPOINT LTC LOW-PRIORITY STEADY STATE LOWER SETPOINT
LTC HIGH-PRIORITY INRUSH CURRENT UPPER
801 LTC HI-ALARM INRUSH CURRENT UPPER SETPOINT SETPOINT
802 LTC LO-ALARM INRUSH CURRENT UPPER SETPOINT LTC LOW-PRIORITY INRUSH CURRENT UPPER SETPOINT
LTC HIGH-PRIORITY INRUSH CURRENT LOWER
803 LTC HI-ALARM INRUSH CURRENT LOWER SETPOINT SETPOINT
LTC LOW-PRIORITY INRUSH CURRENT LOWER
804 LTC LO-ALARM INRUSH CURRENT LOWER SETPOINT SETPOINT
805 LTC HI-ALARM TOTAL TAP COUNT SETPOINT VALUE LTC HIGH-PRIORITY TOTAL TAP COUNT SETPOINT
806 LTC LO-ALARM TOTAL TAP COUNT SETPOINT VALUE LTC LOW-PRIORITY TOTAL TAP COUNT SETPOINT
LTC HI-ALARM MOTOR ACTUATION SETPOINT
807 VALUE LTC HIGH-PRIORITY MOTOR ACTUATION COUNT SPT
LTC LO-ALARM MOTOR ACTUATION SETPOINT
808 VALUE LTC LOW-PRIORITY MOTOR ACTUATION COUNT SPT
809 LTC HI-ALARM TOTAL RUN TIME SETPOINT VALUE LTC HIGH-PRIORITY TOTAL RUN TIME SETPOINT
810 LTC LO-ALARM TOTAL RUN TIME SETPOINT VALUE LTC LOW-PRIORITY TOTAL RUN TIME SETPOINT
811 COOLING BANK 1 DIFFERENTIAL SETPOINT CB1 DIFFERENTIAL SETPOINT VALUE
812 COOLING BANK 1 DIFFERENTIAL HYSTERESIS CB1 DIFFERENTIAL HYSTERESIS VALUE
813 COOLING BANK 2 DIFFERENTIAL SETPOINT CB2 DIFFERENTIAL SETPOINT VALUE
814 COOLING BANK 2 DIFFERENTIAL HYSTERESIS CB2 DIFFERENTIAL HYSTERESIS VALUE
115 www.qualitrolcorp.com
Protocol Manual
ANALOG OUTPUTS
I/O
ADD DATA VARIABLE DESCRIPTION
815 COOLING BANK 3 DIFFERENTIAL SETPOINT CB3 DIFFERENTIAL SETPOINT VALUE
816 COOLING BANK 3 DIFFERENTIAL HYSTERESIS CB3 DIFFERENTIAL HYSTERESIS VALUE
817 COOLING BANK 4 DIFFERENTIAL SETPOINT CB4 DIFFERENTIAL SETPOINT VALUE
818 COOLING BANK 4 DIFFERENTIAL HYSTERESIS CB4 DIFFERENTIAL HYSTERESIS VALUE
819 RELAY 1 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
820 RELAY 2 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
821 RELAY 3 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
822 RELAY 4 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
823 RELAY51 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
824 RELAY 6 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
825 RELAY 7 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
826 RELAY 8 AMBIENT SETPOINT VALUE AMBIENT LOOKBACK FEATURE SETPOINT
827 RELAY 1 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
828 RELAY 2 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
829 RELAY 3 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
830 RELAY 4 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
831 RELAY 5 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
832 RELAY 6 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
833 RELAY 7 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
834 RELAY 8 SEASONAL SETPOINT VALUE SEASONAL SETPOINT VALUE
835 LTC HI-ALARM DIFFERENTIAL SETPOINT VALUE DIFFERENTIAL SETPOINT VALUE FOR HI-ALARM
836 LTC HI-ALARM DIFFERENTIAL HYSTERSIS VALUE DIFFERENTIAL HYSTERESIS VALUE FOR HI-ALARM
837 LTC LO-ALARM DIFFERENTIAL SETPOINT VALUE DIFFERENTIAL SETPOINT VALUE FOR LO-ALARM
838 LTC LO-ALARM DIFFERENTIAL HYSTERSIS VALUE DIFFERENTIAL HYSTERESIS VALUE FOR LO-ALARM
839 LTC HI-ALARM MOTOR RUN TIME SETPOINT MOTOR RUN TIME SETPOINT FOR HI-ALARM
840 LTC LO-ALARM MOTOR RUN TIME SETPOINT MOTOR RUN TIME SETPOINT FOR LO-ALARM
INTEGRATED TOTALS
I/O
ADD DATA VARIABLE DESCRIPTION
TRANSLIFE 1; TRANSFORMER LIFE
1000 CONSUMPTION TOTAL LIFE CONSUMPTION CALCULATED; TRANSLIFE 1
TRANSLIFE 2; TRANSFORMER LIFE
1001 CONSUMPTION TOTAL LIFE CONSUMPTION CALCULATED; TRANSLIFE 2
TRANSLIFE 3; TRANSFORMER LIFE
1002 CONSUMPTION TOTAL LIFE CONSUMPTION CALCULATED; TRANSLIFE 3
1003 TOTAL TRANSFORMER OPERATING HOURS CUMULATIVE TRANSFORMER OPERATING HOURS
1004 COOLING BANK 1 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
1005 COOLING BANK 1 RUN TIME SETPOINT VALUE COOLING BANK 1 TOTAL RUN TIME SETPOINT
1006 COOLING BANK 2 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
1007 COOLING BANK 2 RUN TIME SETPOINT VALUE COOLING BANK 2 TOTAL RUN TIME SETPOINT
1008 COOLING BANK 3 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
1009 COOLING BANK 3 RUN TIME SETPOINT VALUE COOLING BANK 3 TOTAL RUN TIME SETPOINT
1010 COOLING BANK 4 ACTUATION SETPOINT VALUE TOTAL ACTUATION COUNT SETPOINT
1011 COOLING BANK 4 RUN TIME SETPOINT VALUE COOLING BANK 4 TOTAL RUN TIME SETPOINT
1012 LTC HI-ALARM TOTAL TAP COUNT SETPOINT LTC HIGH-PRIORITY TOTAL TAP COUNT SETPOINT
1013 LTC LO-ALARM TOTAL TAP COUNT SETPOINT LTC LOW-PRIORITY TOTAL TAP COUNT SETPOINT
1014 LTC HI-ALARM TOTAL RUN TIME SETPOINT LTC HIGH-PRIORITY TOTAL RUN TIME SETPOINT
116 www.qualitrolcorp.com
Protocol Manual
INTEGRATED TOTALS
I/O
ADD DATA VARIABLE DESCRIPTION
1015 LTC LO-ALARM TOTAL RUN TIME SETPOINT LTC LOW-PRIORITY TOTAL RUN TIME SETPOINT
1016 LTC HI-ALARM MOTOR ACTUATION SETPOINT LTC HIGH-PRIORITY MOTOR ACTUATION COUNT SETPOINT
1017 LTC LO-ALARM MOTOR ACTUATION SETPOINT LTC LOW-PRIORITY MOTOR ACTUATION COUNT SETPOINT
117 www.qualitrolcorp.com
Protocol Manual
118 www.qualitrolcorp.com
Protocol Manual
Select the Ethernet tab and enter the IP Address, Subnet Mask and the Gateway addresses.
119 www.qualitrolcorp.com
Protocol Manual
120 www.qualitrolcorp.com
Protocol Manual
Enter the passwords if required. To configure the client for IEC 61850 reference the following
documents:
IST-100-2 509ITM Model Implementation Conformance Statement
IST-100-3 509ITM Protocol Implementation Conformance Statement
IST-100-4 509ITM Protocol Implementation eXtra Information for Testing
IST-100-5 509ITM TISSUES Implementation Conformance Statement
IST-100-6 509ITM Devices Organization
121 www.qualitrolcorp.com
Protocol Manual
About Qualitrol:
Qualitrol manufactures substation and transformer monitoring and protection devices used by electric utilities and
manufacturing companies. It is the global leader in sales and installations of transformer asset protection equipment, fault
recorders and fault locators. Established in 1945, Qualitrol produces thousands of different types of products on demand,
each customized to customers' unique requirements.
©2008 QUALITROL Company LLC, an ISO 9001 system certified company. All rights reserved. Information subject to change without notice.
®
All trademarks are properties of their respective companies, as noted herein. IST-099-1.
122 www.qualitrolcorp.com