Recommended Mounting Information

• The recommended mounting height for the EF-45 is 155cm (61 inches) from
floor to the bottom of EF-45. The mounting height can be adjusted to
accommodate the height of the average user within the population.

• Strong ambient light and / or direct light into the front side of the EF-45 should
be avoided. Sunlight, halogen lamps or other strong illumination may reduce
the performance of the EF-45 and may result in increased failure-to-capture
rates or failed authentication events.

• The EF-45 was designed for indoor use only. This unit is not weatherproof and
must not be exposed to water, ice, extreme temperatures or other adverse
weather conditions. If it is required to use this unit in outdoor or extreme
environments contact local sales or service@cmi-tech.com for more
information.

Note: Installation in extreme environments without proper protection may cause


permanent damage and void warranty.

www.cmi-tech.com v0.1.5
Copyright 2017, all rights reserved March 2017
General Wiring Requirements
The EF-45 requires at least the following wiring:
• Ethernet network wiring to connect with the network switch for communication.

• Note: Cat5 cable or better is recommended.

• Power input cable wiring: 20 AWG

• Power Input requirement: 12VDC +/- 5%, minimum 42W (12VDC @ 3.5 amps)

Note: Use of stable power supply and proper gauge wire is required. Any over-
or under-voltage applied to this unit may cause permanent damage and void the
warranty.

Standard Installation to Wall Surface or Gang Box


Detach the installation plate from the EF-45 by removing the screw (M3 x 6mm) at the
bottom of unit. Separate the wall plate from the rear cover by sliding the plate
downward. Screw will be re-used to attach the EF-45 to the wall plate following
installation of the wall plate and wiring.

M3 x 6mm screw. Can be


replaced with a M3 security
type screw of proper length.

• Installation can be accomplished by mounting directly to a wall (Surface Mount)


or to a Gang Box.

• For a Surface Mount installation, place the installation (wall) plate on the desired
wall location and screw into wall as indicated in the Surface Mount diagram
below. Ensure that bottom tab in plate faces outward and cable routing
opening in EF-45 matches opening in wall. Utilization of wall anchors is
mandatory.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Wall Mount Installation

Gang Box Installation


For a Gang Box installation, place installation (wall) plate over gang box, and attached
with screws as indicated below. Ensure that tab at bottom of plate faces outward and
cable routing openings match.

Attaching EF-45 to Wall Bracket

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Slide the EF-45 into the installation wall bracket (back plate) from the top.

Lock the EF-45 with bracket using M3 x 6mm screw on bottom. Installers are welcome
to utilize security type screws.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Back View of System with Connectors

1. Heat Sink
2. Tamper Switch
3. External WiFi Antenna Outlet
4. External WiFi USB Socket
5. Tri-pod mount: ¼ - 20 UNC (standard consumer camera mount)
6. Power Input and I/O Interface
7. I/O Interface Cable Outlet
8. I/O Interface Cable Outlet
9. I/O Interface Cable Outlet

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Power Input and I/O Interface Block

1. LAN Connector (RJ45)


2. RS-485 Termination Resistor Switch
3. RS-485 Connector
4. RS-232 Connector
5. GPI Connector
6. Wiegand Input Connector
7. Wiegand Output Connector
8. DC Power Input Connector
9. Relay Connector
10. Factory Reset Switch
11. External Audio Output Connector
12. Serial Debug Port

Connector Information
www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
LAN Connector
RJ-45 connector for 10/100Base-T Ethernet communication, minimum CAT5 cable.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
RS-485 Termination Resistor Switch
Switch for 100 Ohm termination resistor activation when EF-45 connected to the
end of RS-485 wire connection to the other.
Default: Turned off

RS-485 Connector
This is used for communication with Access Control Unit or remote PC based
system or controller.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
RS-232 Connector
This allows for external communications with serial device similar to Smart Card
Reader or Pin-PAD.

GPI Connector
GPI input is used for sensing the Exit button or Door Open Sensor.
It is TTL level based circuit and is pulled-up by an internal resistor.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Wiegand Input Connector
The Wiegand Input DATA0 and DATA1 are pulled-up by internal DC +5V supply.

Wiegand Output Connector


To make Wiegand out working properly, the DATA0 and DATA1 are pulled-up by 1K
Ohm internal resistor as default.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
DC Power Input Connector
Clean and sustainable DC +12V / 3.2 A power is needed for reliable EF-45
operations.

Relay Connector
Internal relay interface with nominal switching capacity of 1A 30VDC or 0.3A
124VAC, resistive load.

Factory Reset Switch


If Factory Reset Switch pushed over 3 seconds then system will re-initialize all the
parameter’s to default and reboot the system.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
External Audio Output Connector
Connector for external audio output.

Serial Debug Port


This serial debug port is used for debugging the system by CMITech Service or
Engineering. It is not available to user.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
USB WiFi Installation – Internal Antenna Type
Notes:
1) Ensure that LAN connection is removed from EF-45 in advance.
2) Put USB WiFi when EF-45 is turned off
3) After installation turn on EF-45.
4) Choose a network in Setting > Network > WiFi > Scan and select DHCP or
Static.
The performance of WiFi is affected by local environment and the type of AP
(Access Point). It is necessary to utilize only CMITech authorized USB WiFi
devices.
CMITech authorized internal antenna is model TL-WN823N made by TP-LINK.
Please find a local market or international web store to buy this model. Contact
sales@cmi-tech or service@cmi-tech.com for support.
Usage of other USB WiFi adapters may not work properly with EF-45 system due to
lack of proper Linux driver.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Relay Connection – Fail Safe Lock (Dead-Bolt Type Door Lock)
Notes:
1) Ensure that direction of the diode is correct.
2) Install the diode close to the door lock.
3) Use different power supplies for the EF-45 and the door lock.
4) Install the diode at both ends of the circuit as shown in the figure below
in order to protect the relay contact from the reverse current that occurs
when the door lock works.

There are two types of dead-bolt door lock connections / configurations supported:
1. Single EF-45 system with one lock (fail secure lock)
2. Two EF-45 systems with one lock (fail secure lock)

Single EF-45 configuration

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Dual EF-45 configuration

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Relay Connection – Automatic Door

TTL Input Port Connection – RTE Switches

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Wiegand Input Connection – External Reader

Notes:
1) Ensure that Data 0 and Data 1 should be pulled up by external resistor.
2) Please be sure that the EF-45 made until the end of year 2017 are all
internally pulled up by 1K resistor to EF-45 internal +5V.
The production made from the year of 2017 the internal resistor will be
terminated. You can find the production date by the serial number.
UMX-10 HC07 represents that the product was made in 2016.
UMX-10 HC08 represents made in 2017.

Wiegand Output Connection – External ACU / Controller

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Notes:
1) Please be sure that the Data0 and Data 1 are internally pulled up by
4.7K resistor to internal +5V VCC of EF-45.

RS-485 Network Connection


Note: The devices at the end of the RS-485 bus network must be terminated.
The signal quality will vary depending on wiring and so it may be necessary to
adjust the communication speed (baud rate) as needed. The GND signal may be
omitted only if the GND potential difference is less than DC ±5V.

Ferrite Core Installation


Note: It is recommended that cables listed below can be wound around the core
by 2 turns if it is connected to an external device for reliable system performance
needed. This is not the mandatory requirement for using Ferrite Core.
1. RS-232 cable
2. RS-485 cable
3. Power cable
4. TTL/Wiegand cable

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017
Contact:

CMITech Company, Ltd.


#904, 25, 248 Beon-gil, Simin-daero,
Dongan-gu, Anyang-si, Gyeonggi-do,
14067 Republic of Korea
Tel: +82.70.8633.8278
sales@cmi-tech.com or service@cmi-tech.com

CMITech America, Inc.


2033 Gateway Place, Suite 500
San Jose, CA 95110
Tel: (1) 408 573 6930

CMITech Company, Ltd. reserves the right to make changes to specifications and features shown herein, or discontinue the
product described at any time without notice or obligation.

www.cmi-tech.com v0.1.5
Copyright 2017 all rights reserved March 2017

You might also like