Byte Symbole Name Function

APS (automatic Protection this byte along with first five bits of the K2 byte
K1 (MSOH)
Switching) allocated for the protection of the multiplex section

the first five bits of the K2 byte allocated for the


protection of the multiplex section along with K1
byte. b6, b7, b8 are used to return an indecation to
K2 (MSOH) the transmiter Tx that the reciever Rx detected MS-
AIS by inserting 110 code
APS (automatic Protection
Switching) and MS-RDI(Remote
Defect Indecation)
this byte is used to send the remote error code
indecation of the multiplex section detected by BIP-
24 (B2).
MS-REI (Multiplex Section-
M1 (MSOH)
Remote Error Code Indecation)

error monitoring shall be Bit Interleaved Parity 24


(BIP-24) code using even parity. The BIP-24 is
multiplexer section error computed over all bits of the previous STM-N
B2 (MSOH) frame. If the error code 1/1000 MS-BBE alarm will
monitoring
appear

E2 (MSOH) multiplexer section order wire this byte used to transmit speech signal between
multiplexeres

this byte resposible for synchronization of the


S1 (MSOH) synchronization status (clock) multiplexeres b5-b8 forming the clock bits while b1-
b4 bits are reserved for future
D4-D5-D6-D7-
D8-D9-D10- Data Communication Channel
D11-D12 (DCC) used to carry Operation Administration and
(MSOH) Maintenance (OAM) informations between
multiplexeres
Lost Extra

APS (automatic Protection Switching)

MS_AIS (Multiplex Section-Alarm Indecation Segnal). MS-RDI(Remote Defect


Indecation)

MS-REI (Multiplex Section-Remote Error Code Indecation)

MS-BBE (Multiplexer
Section- Back Ground
Block Error)