Calibration Certificate - Fluke - RCD Tester

You might also like

Download as pdf
Download as pdf
You are on page 1of 2
Fluke Corporation Everett, Washington 98206 USA Certificate of Calibration ‘The Fluke Corporation, NQA ISO 9001 :2008 ISO Certification No 10100, certifies that the instrument identified herein was calibrated in accordance with applicable Fluke calibration procedures. Their calibrations processes are IS0-9001 controlled and are designed to verify the instrument was within its published specifications at the time of calibration, This calibration is traceable to the SI through recognized national measurement institutes, ratiometric techniques, consensus standards, or natural physical constants. The calibration has been completed in accordance with the Fluke Quality System document QSD 111.0. This certificate applies to only the item identified and shall not be reproduced other than in full, ‘without the specific written approval by Fluke Corporation. The user is obliged to have the object recalibrated at appropriate intervals. In the attached measurement results, measurement error may be expressed with units, (measurement error equals measured result subtracted from the reference value) or as a proportion of the measurement error to the reference value expressed as percent. Quality Assurance Manager Fluke Corporation For customer uso only Please fil in appropriate dates as indicated: Date Instrument Received: NA [“* ] 202.0 Date Catibration Due: Wo (7% 207) ow geno 72018 Fluke Corporation Jephone ‘i Bal PORKEER "42834716100 wEHESTIC pw ake oe Production Verification Test Data Model: 1664FC SN: 4975038 Date: 12/05/2020 Function Applied Stimulus Response Low Limit High Limit Units VAC 0.4: V @ 60 Hz 04 VAC 230 V @ 50 Hz 229.5 VAC 495 V @ 50 Hz 493.7 RLO 20 Ohm range at 19.65 Ohm 19.67 RLO 200 Ohm range at 196.5 Ohm 196.1 RLO 2000 Ohm range at 1965 Ohm 1954 RLO Test current 250 mA at 2 Ohm 0.26 RISO Test voltage 500 V 520 RISO Insulation resistance 0.50 MOhm 0.50 RISO Insulation resistance 225 MOhm 225 RISO Test current 1 mA at 500 kOhm (nominal) 0.00102 RISO _ Test voltage 1000 V 1037 RISO Insulation resistance 0.1 MOhm On RISO Insulation resistance 1.0 MOhm 10 RISO Insulation resistance 195.0 MOhm 194.9 RISO Insulation resistance 900 MOhm 899 RISO Test current 1 mA at | MOhm (nominal) 0.00102 Zl Line-Neutral 0.50 Ohm at 230 V/5S0Hz 0.50 ZI Line-Neutral 18.00 Ohm at 230 V / 50 Hz 18.03 Zl Line-Neutral 180.0 Ohni’at 110 V / 60 Hz 179.4 Zi Line-PE 1800 Ohm at 240V/50Hz 1837 RCD deltaT Tripping speed test at 30 mA. 296 RCD deltaT Tripping speed current at 30 mA 0.032 RCD deltaT Tripping speed test at 1000 mA 297 RCD deltaT Tripping speed current at 1000 mA. 1.079 RCD Idelta 10 mA RCD trip current at 750 ms, PASS RE Compliance voltage 25 V 2 RE Frequency 128 RE 200 Ohm range at 0.5 Ohm 07 RE 2000 Ohm range at 1800 Ohm 1798 Phase Seq. Correct sequence "1-2-3 PASS Phase Seq. Incorrect sequence "3-2-1" PASS 0.1 227.9 490.8 19.33 193.3 1933 0.20 500 0.47 202.5 0.00100 1000 0.0 07 191.8 810 0.00100 0.45 17.60 176.4 1692 291 0.030 291 1.000 20 124 0.0 1727 07 232.1 499.2 19.97 199.7 1997 0.30 550 0.53 247.5 0.00110 1100 04 13 198.2 990 0.00110 0.55 18.40 183.6 1908 299 0.033 299 1.100 30 132 1.0 1873 v) wv) wv) (Ohm) (Ohm) (Ohm) (A) Ww) (MOhm) (MOhm) (A) (v) (MOhm) (MOhm) (MOhm) (MOhm) (a) (Ohm) (Ohm) (Ohm) (Ohm) (ms) (A) (ms) (a) ™) (Hz) (Ohm) (Ohm)

You might also like