Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Model ZR202G---L

Drawings Integrated type


Zirconia Oxygen / High Temperature
Humidity Analyzer
 Reference gas/Except for Pressure compensation (-C, -E)
Unit : mm
48.5

Terminal box side


Display side
Ø50.8

Ø123

170
122 125
Flange

L 338 to 351
t
Rc1/4 or 1/4NPT
Reference gas inlet
C

ØA
Ø50.8

25

ØB

Rc1/4 or 1/4NPT
Calibration gas inlet
Flange
153 to 164
2-G1/2,2-1/2NPT etc.
252 to 265 49 Cable connection port

Unless otherwise specified,differences in the dimensions are specified as: General tolerance = 6 (Criteria of tolerance class it18 in JIS BO401-1986) - 2.

All Rights Reserved, Copyright © 2000, Yokogawa Electric Corporation.


Subject to change without notice.
SD 11M12B02-08E 1/3
1st Edition : Oct. 2000 (YK)
4th Edition : Feb. 2015 (YK)

P-
2

 Reference gas / with Pressure compensation (-P) Unit : mm

48.5

Terminal box side


Display side
Ø50.8

Ø123

170
Flange 122 125

L 342±4
t
Rc1/4 or 1/4NPT
Reference gas inlet
C
*1 Ensure that the flange gasket
ØA does not block the reference gas outlet
on the detector flange.
25

If the flange gasket blocks the outlet,


33

the detector cannot conduct pressure


*1 ØB
compensation.
Reference gas outlet PIPING Where necessary, make a notch
:B on the flange gasket.
Flange
PIPING:A 2-G1/2, 2-1/2NPT etc.
156±3 Stop Cable connection port
256±4 Valve 49
Rc1/4 or 1/4NPT
Calibration gas inlet

Flange Weight
Model, Code L PIPING (kg)
Specification A B C t
ZR202G-040--L 400 Approx. 9
ZR202G-070--L 700 Approx. 10
ZR202G-100--L 1000 Approx. 11
1500 JIS 10K-65-FF 175 140 4-Ø19 18 A
ZR202G-150--L Approx. 13
ZR202G-200--L 2000 Approx. 15
ZR202G-250--L 2500 Approx. 16
ZR202G-300--L 3000 Approx. 18

 HOOD (Option / H)

274 ±4 150 ±3
150 ±3

Hood Material : Aluminum Hood Weight : Approx. 800g

Unless otherwise specified,differences in the dimensions are specified as: General tolerance = 6 (Criteria of tolerance class it18 in JIS BO401-1986) - 2.

SD 11M12B02-08E 2/3
1st Edition : Oct. 2000 (YK)
P- 4th Edition : Feb. 2015 (YK)
3

• Wiring Diagram
Integrated type Zirconia Oxygen/High Temperature Humidity Analyzer

Contact output 1 Contact output 2


Contact input 1

Contact input 2

1 2 3 4 5 6 7
DI-1 DI-2 DI-C DO-1 DO-1 DO-2 DO-2

8 9 10 11 12 13 14
FG AO AO L N G FG
(+) (-)

Analog output 100 to 240 V AC,


4-20 mA DC 50 or 60 Hz
Digital output
F28.EPS

The protective grounding for the analyzer shall be connected either the protective
ground terminal in the equipment or the ground terminal on the case.
Standard regarding grounding: Ground to earth, ground resistance: 100Ω or less.

Unit : mm
• Specified by Option Code

Detector case Detector case

Approx. 44

Approx. 100

40 Ø48

19
Full open height
Calibration gas inlet 58
Rc1/4 or 1/4NPT Calibration gas inlet Rc1/4 or 1/4NPT

 With stop valve (option : /SV) weight : Approx. 200g  Check valve (option : /CV) weight : Approx. 90g

Unless otherwise specified,differences in the dimensions are specified as: General tolerance = 6 (Criteria of tolerance class it18 in JIS BO401-1986) - 2.

SD 11M12B02-08E 3/3
1st Edition : Oct. 2000 (YK)
4th Edition : Feb. 2015 (YK)
P-