BUILDING LAWS DSC2007

PD 1096 – Philippine National Building Code. Adopting National SIZES AND DIMENSIONS OF ROOMS (sec. 806)
Bldg. Code of the Philippines, Revising R.A. 6541 -Human habitation: 6.0 sqm. with least dim. of 2.0 meters 2.0x3.0
R.A. 6541 – An Act to Ordain and Institute a National Building Code of -Kitchen : 3.0 sqm with least dim. of 1.5 meters. 1.5x2.0
the Philippines. -T&B : 1.20 sqm with least dim. of .90 meters .90 x 1.30
- Does not confirm with the developmental goals and infastracture AIR SPACE REQUIREMENTS IN DETERMINING THE SIZE
program of government. OF THE ROOM
- Does not Adequately provide all technological requirements of Minimum air space:
building or structure, in terms of up to date design and construction -classroom - 3.0 cu.m w/ 1.0 sqm of flr area per person
standard criteria. -workshop, factory, offices – 12.0 cu.m. of airspace per person
- Purpose of PD 1096 is to provide and regulate bldg. structures to -habitable room – 14cu.m per person.
reach the minimum standards requirements and to control the location, WINDOW OPENINGS (sec. 808)
site design and quality of materials, construction use occupancy and -For Natural Ventilation 10% of total floor area of the room
maintenance. VENT SHAFT (sec 809)
PD 1096 must apply to design, location, siting , construction, -Unobstructed cross sectional area not less then .30 sqm. With a
alteration, repair, conversion, use occupancy, maintenance , moving, minimum dimension of 300mm.
demolition, addition to public and private building and structure except - Air duct intakes minimum of 300 mm
traditional indigenous houses. ARTIFICIAL VENTILLATION (sec 811)
- Building and structures constructed before the approval on this code -Above grade room like offices, restaurant, market, factory, workshop –
shall not be affected. Except it will apply when some portions will be Not less than 3 Air change per hour.
altered, added, converted or repair. -Bakery, hotels, restaurant kitchen, boiler room – 10 Air change per
TYPES OF CONSTRUCTIONS hour.
Type 1 – Buildings shall be wood construction. -Assembly Area - .30 cu/m per minute supply for every person.
Type 2 – Buildings shall be wood construction with protective fire -Wards and Institutional – Not less than .45 cu/m per minute supply for
resistant materials and with one hour fire resistively. Except for non- each person.
bearing partitions. WALKWAY (sec.1105)
Type 3 - Building shall be masonry and wood construction. It shall - During construction temporary walkway should not less than 1.20 mts.
have 1 hour fire resistive through out. Exterior wall shall be fire -Pedestrian Protection : Railings1.0 mts. high, Fences: 2.40 mts,
resistive construction. Canopy: 2.40 clear height above the railways.
Type 4 - Building shall be steel iron concrete or masonry construction. GEN. DESIGN AND CONSTRUCTION REQUIREMENTS
Permanent walls and partitions shall be fire in combustion. Except -Distance between sprinkler should not exceed 1.80 meters center to
permanent non-bearing partition of 1 hour fire resistive construction, center.
may use fire retardant treated wood for framing. STAIR, EXIT, OCCUPANT LOAD (sec.1207)
Type 5 – Building shall be fire resistive, structural shall be steel. Iron , -1ST Storey - occupant load more than 10 shall have 2 exits.
concrete and masonry construction. -Mezzanine of storage area greater than 185 sqm. Or 18.00 meters in
CLASSIFICATION OF BLDG. OCCUPANCY any length have at lease 2 stairways at adjacent floor.
(Chapter 7 sec. 701 occupancy classified) -Every floor having an occupant load of 500 - 999 shall have 3 exits.
Group A – Residential Dwellings -Having occupant load 1000 or more must have 4 exits.
Group B – Residential, Hotels. and Apartment PERMITS AND APPLICATION (chapter 3)
Group C – Educational and Recreational Sec 302 Application of Permit – 5 Corresponding Plans and
Group D – Institutional Specifications signed by license architect and engineers.
Group E – Business and Mercantile Sec 309 Certificate of Occupancy – shall issue by building official
Group F – Industrial within 30 days after the final inspection and submittal of certificate of
Group G – Storage and Hazardous completion.
Group H – Assembly other than Group 1 STAIRWAY WIDTH
Group I – Assembly Occupant load 1000 or more - Occupant more than 50, minimum of 1.10 meters wide
Group H – Accessory - 50 or less minimum of .90 meters wide
MIN. REQMTS. FOR GROUP. A DUELLINGS - Private stairways less than 10 have .75 meters wide.
- Shall not occupy more than 90% of a corner lot and 80% of inside lot. - Vertical distance between landing not morethan 3.60 meters.
Easement of light and view shall be at lease 2mts from property line. - Minimum Thread = .20 meters Maximum riser = .25 meters
- Footings shall be 250 mm thk. And 600 mm below the surface of the HANDRAILS
ground. - 3.0 meters width of stairs – provide not less than 2 handrails.
- Live load at GF shall be 200kg/sq.mts. for 2 nd flr. At lease - 1.10 meters or less – serving Group A and B have 1 handrails
150kg/sq.mts. - Intermediate railings is not less than 80 mm and not more than 90 mm.
- Wind load for roof shall be at lease 120kg/sq. for vertical projection. - stairways not more than 4 risers don’t need railings.
- Stairs shall be at lease 750 mm clear widths, with rise of 200mm and - Handrail distance to wall – minimum of 38mm.
200mm min. for run. - Handrails – .80 meters to 1.20 meters high.
- At lease 1 entrance and 1 exit. - Handrails diameters are 30mm – 50mm diameter
LIGHT AND VENTILLATION (sec.804 size and dimension of court) INTERIOR WET STAND PIPE – 38mm diameter in every storey
- Minimum horizontal dimension of court shall not be less than 2.o 1.20 meters above the floor.
meters.  1 wet standpipe for more than 1000 persons for assembly building
- Minimum of passageway is 1.20 meters.  15 meters high is known as a high rise building
CEILING HEIGHTS  Fire hose – required 38mm diameter
-Habitable room with artificial ventilation is 2.40 meters from floor to  Down feed water distribution = 132 lit./min.
ceiling. RA 7920 –New Electrical Engineering Law
-Ground floor: 2.70 mts. 2nd floor: 2.40 mts. Floor to ceiling  Electrical installations for more than 20 outlets and more than 4KW
-Succeeding floors not less than 2.10 mts. Above finish floor line. voltage shall sign and seal by professional electrical engineer.
-For natural ventilation: not less than 2.70 meters PLASTICS (chapter 16)
-Mezzanine is not more than 1.80 meters.  Approve plastics are 225 fire spread ratings.
BUILDING LAWS DSC2007

PD 1096 (January 1, 1979) – The National Building Code of the TYPES OF OCCUPANCY
Philippines.  Category l - Residential
 Construction – All site work done from site preparation,  Category ll – Commercial and industrial
(excavation, foundation, assembly, and installation of utilities in the  Category lll – Social, educational, institutional
buildings.  Category lV – Agricultural
 Erection – installation in place of components of building.  Category V – Ancillary
 Addition – any new construction (increase the height or area of FLOOR TO FLOOR HEIGHT – min of 3.0 meters for structures
existing structures. finish floor to finish floor.
 Alteration – changes in material used, partitioning, location or size LOWRISE – From 1 storey to 5 store’s in height from 3.0 meters –
of opening, structural parts and utilities, but does not increase the max of 15.00 meters high.
overall area. MEDIUM RISE – From 6 storey to 15 storey’s in height.( 18.0 meters
 Renovation – Any physical change made on the building to increase – 45.0 meters)
its value (ex. improve aesthetics) HIGH RISE – 16 storey above ( 48.0 meters above)
 Conversion – Change in the use of occupancy in any portion of the REQUIREMENTS FOR OTHER GROUP OCCUPANCIES
structure.  ROW SEATING - 0.84 meters measures back to back of chair.
 Repair – Remedial work done on any damage portions to restore its  BLEACHERS – Riser = .40 meters Run = .60 meters Width of
original condition. person .45-.48 meters.
 Moving – Transfer of any structure from its original loc. Or position  AISLES – 1st = 1.10 meters, 2nd .80 meters, 3rd 1.0 meters.
to another, either in same lot or another. DEFINITION OF TERMS:
 Demolition – dismantling the whole part of the structure.  ABUTMENT – Semi–permanent/permanent structure constructed
 Ancillary Building Structure – Secondary building located within along property line. Ex. Firewall.
the same premises.  INCREMENTAL – Hor. setback along outermost part of a bldg..
DEFINITION OF TERMS: For rear or side property line 0.30mm setback per storey starting second
BLDG OFFICIAL – Charge of duties of issuing bldg permit. floor. For front yard 1.17 meters setback starting at 9 th flr.
BLDG PERMIT – Written authorization granted by bldg official to  FRONT YARD – Part of total open space created by setbacks along
applicant to proceed with the construction. road right of way (RROW).
AGENCY OF THE GOVERNMENT – Refers to any various units of  VENT WELL – Minimal opening along the portion of firewall.
governments. Min. clear width of 3.0 meters, and min. depth of 1.5 meters.
APPALICANT/PERMITTEE – Any character applying for an  FIRE ZONE – Bldg. Permitted to construct base to their occupancy
issuance of permits and certificate. type of construction and resistance to fire.
NATIONAL GOVERNMENT – Entire machinery of central  FIRE RESISTANCE RATING – Degree of material can stand the
government. fire.
PERMIT PRINCIPAL – Ancillary permit pertaining to building  FIRE RESISTIVE TIME PERIOD RATING – Length of time
structures. material can stand when burned
EXCEMPTIONS FOR BUILDING PERMITS:  FIRE RESISTIVE STANDARDS – Classification of construction
 Shed, outhouses not exceeding 6.0sqm according to fire retardant or flame spread rating.
 Garden pools max. of 500mm depth  BUILDING STRUCTURE – 3 dimensional physical developments
 Garden walls max. 1.80 meters high within a lot.
 Indigenous family dwellings  DEVELOPMENT CONTROL – Physical utilization of the lot. Can
 Public buildings determine the carrying capacity of the lot.
 Government own housing units  FIREWALL – Reinforce concrete separator with appropriate fire
 Construction by civic org. and charitable inst. Donated to government resistive rating, position between dwelling units.Permitted vent well for
 Blgd. Owned by electrical cooperatives firewall is 400mm – 1000 mm vertical
BUILDING PERMITS REQUIREMENTS;  LOT – Physical setting of any structure/building.
 Application Form DEVELOPMENT LEVEL OF LOT;
 5 sets of working drawings sign by engineer and architect  Grade – Above surface Lot
For lot owners;  Below Grade - Below surface lot / excavations and backfills
 TCT  Above Grade - Above the surface of the lot up to the air.
 Tax declaration BUILDING HEIGHT;
 Current real property tax receipt  BASEMENT – Below natural and finish grade.
For not lot owners:  BASEMENT FOOTPRINT – Actual land area occupied by the
 Deed of absolute sales basement, measured by its outer wall.
 Contract lease  BUILDING HEIGHT LIMIT – Max. height to be allowed for the
 Contract sale building.
NOT REQUIRED FOR PLANS AND SPECIFICATIONS:  ESTABLISH GRADE ELEVATION – Highest adjoining natural
 Traditional indigenous family dwellings using native materials. Cost grade.
not exceeding P15,000.  FLOOR TO FLOOR HEIGHT – Max. distance of 3.0 meters . A
 Single detached dwellings not more than 20sq.m. perpendicular distance between 2 upper floor levels.
VALIDITY OF BUILDING PERMIT:  GRADE – 1.50 meters horizontal distance between fin. Surface of
 1 year from date of issue. the ground to exterior wall/property line.
 No longer valid after suspension and abandoned of construction for  HEIGHT OF THE STRUCTURE – Vert. clearance from fin.
120 days. Grade line from the highest point of couping.
COMPUTING BLDG. PERMIT FEES;  PODIUM – Full enclosed part of the building. First of typical floors
 Type of occupancy of the building.
 Height and area  RESULTANT HEIGHT – Vertical measurement of propose
 Cost of construction building.
 STOREY – Upper floor to floor finish building.
BUILDING LAWS DSC2007

 TOWER – Fully enclosed component of the building, Not more than - Sign distance from electrical post – 1.0 meters minimum.
5 times the height of the podium. - Distance from property line 2.0 meters minimum.
 ALLOWABLE MAX. BUILDING FOOTPRINT – Max. pportion - Sign to sign distance form adjacent building – 4.0 meters.
of lot that occupied by building . measure at the outermost part wall of PARKING REQUIREMENTS:
the building. Low cost housing – 1:10 minimum
 FRONT YARD – Created by setbacks along RROW. Transition area Condominiums – less than 50 ( 1: 8 ) 50-100 (1:4) morethan 100 1:1
between sidewalk and other similar portion of RROW. Hotels – 1:10 (10 room 1 parking slot)
 FRONT LOT – Side opf the lot which the main pedestrian and Residential Hotels and Apartells – 1:5
vehicular access in the property shall be situated. Offices – 1:125 ( 1 slot for every 125 gross floor area)
 COURT – An occupied space between the faces of the building Schools – High School 1:10 College and University 1:5
lines. Hospital – 1 slot for 25 beds
 INNER COURT – Court bounded on all sides Bowling area – 1 slot for every 4 alleys
---------------------------------------------------------------------------------
 OPEN COURT – Bounded on 3 sides by building lines.
Masonry Min size of columns - .30 x .20 meters
 THROUGH COURT – Bounded on 2 opposite side by building
Masonry Min. circular columns - .25 meters diameter.
lines.
Planting strip - .80 meters
 COURT YARD – A portion of a yard had limit on hardscaping not
Side walk – 1:6 ROW
exceeding 50% of yard area. Smallest size of road: 6.0 meters
 VENT WELL – Permitted opening along vertical portion of Open space requirements is 30%
firewall. Max. width of 3.0 mts. And min depth of 1.50 mts. Masonry Footing : Max depth is .45 mts.
 ROAD RIGHT OF WAY (RROW) – Public open space for Distance Between roof and canopy : .75 meters
continuous flow of pedestrian and vehicular traffic. Min. Eaves Length : 1.2 mts.
PHYSICAL LEVEL OF RROW RAMPS:
 RROW ABOVE GRADE – From finish surface of roadway, Class A: 8-10% slope Class B: 10-17% slope
sidewalk, and arcade way up to air. Max. Curb: .20 mts.
 RROW AT GRADE – Natural gradeline up to the unfinish surface Ideal Ramp : 1:20
of the road SIZES OF LOT:
 RROW BELOW GRADE – From finish surface of the roadway Economic : 72 Sqm. Duplex Single Detached : 48 Sqm.
down to the ground. RAW HOUSING:
--------------------------------------------------------------------------------------- Economic : 36 Sqm. Socialize 32 Sqm.
 EASEMENT – Public open space define under water code Maximum Cluster : 20 Frontage: 3.0 mts
 Min. easement for urban areas 3.0 meters Maximum Block: 100 mts.
 Min. court width 2.o mts. WINDOW REQUIREMENTS:
 Min. walkway is 1.20 mts.  1:10 of room floor area.
OPEN SPACES FOR LOT:  1:20 or 5% of toilet floor area
 INTERIOR LOT – ABCD & J – 50% EFGHI – 20 TO 25% BATAS PAMBANSA BLG.344 ( BP344 ) – The law to enhance
 INSIDE LOT - ABCD & J – 20% EFGHI – 15% mobility of disable person, by requiring certain building, institution,
 CORNER LOT - ABCD & J – 10% EFGHI – 5% establishment and public utitlities to install facilities and other device.
 THROUGH LOT ABCD & J – 10% EFGHI –5% ANTROPOMETRICS:
 CORNER THROUGH LOT - 5% ALL  Length of wheel chair : 1.0 – 1.30 mts.
 CORNER LOT ABUTTING 3 OR MORE STREET – 5% ALL  Width of wheel chair: .60 - .75 meters
PROJECTIONS OVER STREETS:  Turning Radius: 1.50 meters
 Arcade and Balcony – 3.0 meters high  Comfortable Reach : .70 – 1.20 meters from the floor.
 Canopies 3.0 high  Room Corner Reach: .40 meters
 Awning 2.40 meters high  Clearance of leg under the table: .75 meters
PROTECTION ON PEDESTRIAN DURING CONSTRUCTION SPACE FOR DISABLE ( ASSEMBLY AREAS)
AND DEMOLITION:  4 – 50 seating 2 wheelchair space
 1.20 meters wide temporary walkway  51 – 300 4
 1.0 meters high railings  301 – 500 6
 2.40 meters high fence  If the capacity exceed 500, additional space required every 100
--------------------------------------------------------------------------------------- seating increase.
 .60 meters footing extension from property line (national road and RA7277 sec. 46 – MAGNACARTA FOR DISABLE PERSON
public highways --------------------------------------------------------------------------------------
 .30 meters for public sidewalk Outside and Around the Building:
SIGNS: Drop Curb: min. width of .90 meters Lowest dropped Curb .25 mts
 ADVERTISING SIGN – Off-premises sign Ramp: max of 1:12 Slope of Curb: 1:20 to prevent water collecting
 BILLBOARD – Panel for posting bills or posters Curb Cut-Out: Min width of .90 meters Slope 1:12
 DISPLAY SIGN – On premises sign --------------------------------------------------------------------------------------
 Tapping Rail – .30 meters
 GROUND SIGN – Resting on the ground
- Maximun height of 6.0 meters on sign dimension  Walkways – 1.20 meters min
 PROJECTING SIGN – Suspended form the building. Perpendicular  Min. Walkway Headroom: 2.0 meters
to the angle of the surface of the wall.  Max. cross gradient: 1:100
- Non Arcaded – min. of 3.0 mts high - max 1.50 mts from bldg. line HANDRAILS
- Arcaded – min of 5.0 meters high - max 1.0 mts from wall line  Handrail Above the Step of Ramp: .90 meters - .70 meters high
 ROOF SIGN – Parallel to wall surface  Handrail Height: 1.0meters - 1.06 meters
 TEMPORARY SIGN – On light and combustible material.  Handrail Extension: .30 meters for both ramp end
 Full Grip Handrail: .30 meters - .50 meters
 Min. Clearance to the wall: ..50 meters Ledge: .40 meters
BUILDING LAWS DSC2007

SIGNAGES:  Rubbish Chutes, Incinerators and Laundry Chutes


 Min Headroom for walkway: 2.0 meters  Fire Detection, Alarm, Communication Systems
 Signs on Doors and Walls: Max of 1.60 meters Min. of 1.40 meters  Automatic Sprinklers, and other Extinguishing Equipment
 Signage Symbols and Letters: .10 meters Fire Containing Architectural Components
PARKING:  Firewalls
 Min. Width: 3.70 meters  Resistive Floors
 Min Width for front and end passage: 1.20 meters  Resistive Walls
Inside The Structures:  Curtain Boards
 Entrance with Vestibules: 1.50 width - 1.80 depth  Shutter
RAMP:  Dampers
 Provide landing for every 6.0 meters  Self-Closing Doors
 Min clear width of 1.20 meters CLASSES OF FIRE base on the cause
 Maximum gradient is 1:12  Class A – Ordinary combustible materials like wood, cloth, paper
 Min curb for both side of ramp is .10 meters  Class B – Flammable liquids and gases
 Handrails for 2 sides of the ramp .90 meters and .70 meters highramp  Class C - Energized electrical equipment
greater than .20 meters leads toward the vehicular traffic railings, min.  Class D- Combustible materials like sodium, magnesium
of 1.80 meters from the foot of ramp. DEFINITION OF TERMS:
DOORS:  Automatic Fire Suppression System – Integrated system of
 Min Width: .80 meters underground and overhead piping connected to a source of
 Door Opening Pressure: more than 4.0 kg extinguishing agent.
 Clear Space for Extending Beyond the Door: 1.50 meters – 1.50  Fire Alerting System – Activated by the presence of fire, where the
meters (minimum) signal is transmitted to designated locations.
 Door Knobs height from floor: .82 meters - 1.06 meters  Fire Protective Assembly – Incorporated to structure to prevent the
 Kick Plates: .30 meters - .40 meters spread of fire.
-------------------------------------------------------------  Dry Standpipe – Pipe that does not filled with water
Threshold / Change in Floor Level: 0.205 meters  Fire Wall – To prevent the spread of fire. Have a fire resistance of 4
------------------------------------------------------------- hours.
SWITCH:  Means of Egress – Continuous and unobstructed rout of exit to any
 1.20 meters - 1.30 meters above the floor point of the building to a public way.
 .20 meters from latch side of the door  Fire Retardant – Any compound mixture, which applied to
CORRIDOR: materials to improve its fire resistant
 Min clear width of 1.20 meters  Panic Hardware – Mechanical device consisting of linkages and a
 Turn About spaces to pass another wheelchair min. of 1.50 x 1.50 horizontal bar across a door.
meters space at maximum of 12.0 meters  Organic Coating – Liquid mixture of binders and combustible
 Turn about should be provided within 3.50 meters of every dead end solvents which when pread to the surface it becomes durable protective
WASHROOM AND TOILETS: and decorative finish.
 Area of water closet: 1.70 x 1.80 meters  Fire Resistance Rating – Time duration of material can stand the
 Turning space of 2.25 sqm. With min. dimension of 1.50 meters for effect of fire.
water closet lateral; mounting  Flame Spread Rating – Time in which the flame will spread in the
 Signage for toilet: 0.30 meters long and 0.75 meter thick surface of material.
 Equilateral triangle: Men signage  Smoke Developed Rating – Volume of smoke developed within a
 Circle: Woman signage certain period of time.
 Max height of water closet: .45 meters Flush control: 1.20 mts. SEPARATION OF EXIT
 Urinals: Max height of .48 meters.  1 hour fire resistance rating for 3 stories or less
ELEVATORS:  2 hour fire resistance rating for 4 and more stories
 Max of 30.0 meters from entrance TRAVEL DISTANCE
 Elevator min dimension: 1.10 x 1.40 meters  Without fire suppression system – 45.0 meters
 Control panel should be between .90 meters to 1.20 meters high.  With Fire Suppression system – 60.0 meters
STAIRS:  Min width of the door - .71 meters Maximum of 1.22 meters
 Tactive Strip for change level is .30 meters  Area separation - 0.205 meters
WATER FOUNTAINS: TREADS AND RISERS
 1 for every 2000 sqm of floor, atlease 1 for every floor  Sum of 2 risers and treads exclusive of nosing should be between
 Wall mounted maximum height of .85 meters. 0.90 – 0.635 meters
PUBLIC TELEPHONES: LOADS
 1.50 meters from un-obstruction space  Stair, flat form, loading, balcony stair hallway have carrying load of
 1.10 meters hight of the units. 88 kg per sq.meter or concentrated load of 136 kg.
FENCING FOR ROAD WORKS: SLIDE ESCAPES
 1.0 meters min. height of railings  1 exit unit per slide. Traveling time of 60 person per minute
 .35 meters for tapping rails EMERGENCY LIGHTING
PD 1185 THE FIRE CODE OF THE PHILIPPINES AND  Light should last 1.5 hours in building more than 36.5 meters high
REGULATION ( August 26, 1977) EXIT SIGNS
Fire Protection Equipment:  Exit signs shall have max height of 15 cm and principal strokes of
 Utilities letters at lease 19 mm wide.
 Heating , Ventilation , Air-conditioning
 Smoke control
 Elevators and Escalators
BUILDING LAWS DSC2007

GENERAL PROVISION FEATURES OF FIRE PROTECTION DEFINITION OF TERMS


 Sprinkler Vent Method – Combination of Automatic smoke detection  Combination Standpipe – with constant water supply use for fire
system, automatic exhaust system and automatic water curtain service
 Spray Nozzle Methods – Combination of automatic smoke detection - minimum of 15 cm diameter
system and high velocity water spray nozzle. - 4 way connection for combination of 2 system
 Rolling Shutter Method – Automatic self rolling shutter. Completely - (2) 4way connection for combination of 3 or more system
enclose the top of escalator - 64 mm diameter outlet in .61 mts to 1.22 mts above floor each storey
 Partial Enclosure Method – Kiosk designed to provide an effective  Dry Standpipe – without a constant water supply with a fire service
barrier to the spread of smoke floor to floor inlet and outlet connections.
 Fire Stopping Concealed Spaces – Concealed space in which expose - One outlet connection every floor level
materials have fire spread ratings greater than Class A. - Will stand 21 kg/sq.cm of water pressure
FIRE SAFETY IN BUILDINGS, STRUCTURE AND FACILITIES - 20% slope of horizontal runs
CLASSIFICATION OF OCCUPANCY AND HAZARD - 102 mm diameter for 23 meters highest outlet connection
CONTENT - 153 mm diameter for higher than 23 meters outlet connection
Fire Safety in Places of Assembly - 102 mm diameter dry standpipe for 4way connections
 Main exit must occupied 50% of occupant load - .46 meters – 1.22 meters high connection at front street above grade
 Travel distance with Automatic Fire Suppression is 46 meters - 6.4 cm outlet and .61 mts – 1.22 mts above flr level each storey
 Without protection 61 meters from the exit.  Wet Standpipe – with constant water supply installed primary for
Multiple Seating emergency
 Rows of seat between aisles max of 14 seats - Assembly bldg. more than 1000 occupants.
- Required for Hazardous storage, business and mercantile occupancies
 7 rows to open 1 aisles only
more than 1,860 sq.m
 back to back facing max of 0.83
- 6 meters nozzle attached to 22 meters of hose
 seats without dividing arms: .60 per person
- 64 mm diameter if height of the riser is 15 meters above
 aisles width: 0.91 – 1.0 for more than 60 seats - 51 mm diameter if less than 15 meters
0.76 for less than 60 seats - 38 mm diameter valve per storey, .91 mts to 1.92 mts above flr
GENERAL PROVISIONS: PLACES OF ASSEMBLY - 132 lit/min with 1/8 kg/sq.cm pressure for each outlet for 30 mins.
 Class A: 1000 or more 4 exits - 38 mm diameter min. per standpipe
 Class B: 600 or more 3 exits  Fire Dept. House Connection – a hose connection at the street level
300 – 600 2 exits NATIONAL STRUCTURAL CODE FOR BUILDINGS
 Class C: 50 – 300 2 exits Board Resolution No. 4 Series of 1972
Occupant Loads DEFINITIONS:
 Without fixed seats such as auditorium, church: 0.65 sqm./ person  Dead Load – Shall include the weight of the walls, permanent
 Less concentrated such as conference room, dining room, exhibition partitions, framing, floors, roofs, and all other permanent stationary
room, gymnasium: 1.4 sqm/person construction entering into and becoming part of the building.
 Standing Room or Waiting Space: 0.28 sq.m/person  Live Load – Shall include all loads except dead and lateral loads:
GENERAL PROVISIONS: weight of the people, furniture, equipment and all movable elements.
Educational Occupancies  Lateral Load – Include horizontal load due to seismic, wind forces,
 Room with 50 person or over 93 sqm shall have 2 exits blast and other loads in the same direction
Occupant Loads  Unit Live Load – The minimum live loads per unit area of horizontal
 Classroom 1.80 sq.m/person projection.
 Shop, Lab, vocational room 1.40 sq.m/person  Uniformly Distributed Load – Min. average amount allowed on a
 Dry nurses w/ sleeping facility 3.25 sq/m/person floor and determined by occupancy or use,
Institutional Occupancies PHILIPPINE ELECTRICAL CODE
 Healthcare facilities: hospital and nursing homes DEFINITIONS:
 Residential Custodial area: Nurseries, Home for the Age, Mentally  Appliance – Utilization equipment, installed connected as a unit to
Retarded Care performed one or more functions. Ex. Airconditoning, washing machine
 Residential – Restrained Care: Penal Institutions, Reformaries, Jails  Assembly – Combination of a portion of equipment parts included in
Residential Occupancies an electrical apparatus mounted on a supporting frame or a panel and
 Hotels: More than 15 accommodations for hire properly inter-wired.
 Apartment : 3 or more accommodating units with T&B  Bonding – Permanent adjoining of metallic parts to form an electrical
 Dormitories: Group sleeping accommodations conductive path.
 Lodging or Rooming Houses: Separated rented living rooms for 15 or  Branch Circuit – Circuit conductors between the final over current
less, transient or permanent basis device protecting the circuit and the outlets.
Miscellaneous Occupancies  Cable – Stranded conductors, combination of conductors insulated
 Ordinary Hazard from one another
 High Hazard  Circuit Breaker – Devise design to open and close a circuit by non
 Low Hazard automatic means and to open the circuit automatically on a pre
MAINTENANCE OF EXIT WAYS determined over current without injury to it self when properly applied
Stairways within its rating
 .90 meters high for handrail  Demand Factor – The ratio of the max. Demand of a system. The
 1.95 meters headroom clearance total connected load of a system or the part of the system under
Ramps consideration
 1/8 or 12.5% slope
 Handrails required for 1/10 slopes
Signs and Illumination
 1 foot candle for light intensity
 Exits signs with letters at lease 12.7 cm high w/ 2 5 watts light
BUILDING LAWS DSC2007

THE URBAN DEVELOPMENT AND HOUSING ACT Minimum Frontage:


REPUBLIC ACT 7279 March 24, 1992 Corner lot: 8.0 meters
Objectives: Regular lot: 8.0 meters
 Decent and affordable housing with basic services and livelihood Irregular lot: 4.0 meters
opportunities, Interior lot : 3.0 meters
 Disperse urban net and more balance urban-rural inter dependence DUPLEX/SINGLE ATTACHED
 Equitable land tenure system Minimum lot areas
 Improve LGU capability Economic: 54 sq. m 9.0 x 6.0
Strategies: Socialize: 48 sq.m 8.0 x 6.0
 Balance housing Minimum frontage
 Private sector participation Economic: 6.0 meters
 Country side development Socialize: 6.0 meters
ROW HOUSE
 Government intervention in land acquisition
Min lot areas
KEY HOUSING AGENCIES
Economic: 36 sq.m 6.0 x 6.0
 HUDCC – Planning and technical assistance
Socialized: 32 sq.m 8.0 x 4.0
 NHA – Augment and enhance local government capabilities Minimum frontage
 HIGC – Guarantee schemes to encourage financial institutions Economic: 3.5 meters
 HLURB – Comprehensive plans for urban and urbanized area Socialized: 3.5 meters
 NHMFC – Community mortgage program  Max of 20 units per block or cluster
Other Entities  Max block length of 100 meters
 LGU – Comprehensive Land Use Plan Min floor areas:
 NEDA – Data for forward planning Economic: 22 sq.m
 Private Sectors and NGO – Investments Socialized: 18 sq.m 3.0 x 6.0
Products: Minimum setbacks:
 Rationally site settlements, livelihood components, basic services, Front: 1.50 meters
affordable package, need specific units, use of indigenous materials and Side: 2.0 meters
alternative technologies. Rear: 2.0 meters
REVISED RULES AND STANDARDS FOR ECONOMIC AND MINIMUM LEVEL OF COMPLETION
SOCIALIZED HOUSING PROJECTS TO IMPLEMENT BATAS Economic – Complete based on specification
PAMBANSA BLG, 220 ( BP 220 ) Socialized – Shell house with doors and windows to enclose the unit
 Economic Housing – House and Lot package – P500,000 WATER SUPPLY
 Socialized Housing – House and Lot package – P180,00  Independent water supply system at 150 lit/capita/day
Basic Needs:  Ground reservoir 25 meters from source of contaminants
 Water, Movement and circulation, Storm drainage, Solid and liquid POWER SUPPLY
water disposal, Parks and playgrounds, Power  Provide 1 street light per pole when pole spaced at 50 meters
Site Criteria:  Provide 1 street light every other poles when pole spaced less than 50
 Conformity with zoning ordinances and land use plan meters.
 Physical suitability NON – RESIDENTIAL USE
 Accessibility  Floor area authorized for non-residential use shall not exceed 25% of
Land Allocation: total residential area.
 No fixed ratio between saleable and non salable portions ELEVATOR
Parks and Playgrounds:  Min of 5 storey to provide elevator
 Centrally located STAIRS
 Mandatory of 1 Has. And above  Internal: .15 mts Middle: .30 mts. Outside: .30 meters
 Non- alienable  Max. travel distance to stairways: 24.0 meters
Street:  Min. head clearance: 2.0 meters
 Aspalt - 2” min. thick for pavement  Max. height of landing to landing: 3.60 meters
 Concrete – 6” min. thick for concrete  Min. stairway width : .60 meters
 Major Road: 1.0 mts sidewalk, 1.0 mts. Plant strip, 8.0 mts  Handrail height: .80 – 1.20 meters
carriageway. Total of 12.0 mts ROW CORRIDORS
 Minor Road: 1.0 mts. Sidewalk, 1.0 mts plant strip, 6.0 mts  Min clear 1.20 meters
carriageway. Total of 10.0 mts ROW MIN. DISTANCE BETWEEN BUILDINGS
Alleys and Pathwalks:  3 – 4 storey –Wall to wall distance 5.0 mts Line of roof: 2.0 mts.
 To serve as block breaker  Single storey –Wall to wall dist. 2.0 mts Line of roof: 1.0 mts
 3 meters ROW  1 – 2 storey – Wall to wall dist. 4.0 mts. Line of roof: 1.50
 Max. length of 60.0 meters FIREWALLS
 Pave with madacam  Min of .30 mts from apex of roof, and from wall for duplex/single
Cul-De-Sac / Turnabout – 120 mts max. length, 10.0 mts wide ROW, detached.
turning radius from main road = 6.0 mts. , turning radius from minor REVISED RULES AND REGULATIONS IMPLEMENTING THE
road = 4.5 meters, diameter = 21-31 SUBDIVISON AND CONDOMINIUMS BUYERS PROTECTIVE
Block Length: DECREE AND OTHER RELATED LAWS PRESIDENTIAL
 Max. of 400 mts. DECREE 957 ( PD 957 )
 Provide 3.0 mts. Pathwalk or alley blocks exceeding 250 meters Land Allocation
SINGLE DETACHED UNITS:  Open Space : 30%
Min lot areas:  Salable Area: 70% maximum
Economic – 72 sq.m 9.0 x 8.0
Socialized – 64 sq. m 8.0 x 8.0
BUILDING LAWS DSC2007

Selling Price
 Open Market: P 2,000.00 Above
 Medium Cost: P 500,000 – 2,000,000
LOTS
 Single-Detached Units
Min. lot areas
Open Market: 120 sq.m
Medium Cost: 100 sq.m
Minimum frontage
Corner lot: 12 meters
Regular lot: 10 meters
Irregular lot: 6.0 meters
Interior lot: 3.0 meters
 Duplex / Single-Attached
Min. lot areas
Open Market: 96 sq.m
Medium Cost: 80 sq.m
Minimum frontage 8.0 meters
 RowHouse
Min. lot areas
Open Market: 60 sq.m
Medium Cost: 50 sq.m
Minimum frontage 4.0 meters
HOUSES
Min. Floor areas
Open Market: 42 sq.m
Medium Cost: 30 sq.m
Min. Setbacks
Front: 3.0 meters
Side: 2.0 meters
Rear: 2.0 meters