COLUMN SCHEDULE

Floor No. of columns


Size of column X x Y
Main steel
Third Floor ( centre of third
Ties near slab
floor to terrace )
Third Floor ( centre of third
floor to terrace )
Ties in central height
Mix
Size of column X x Y
Main steel
Second Floor ( centre of
second floor to centre of Ties near slab
third floor )
Ties in central height
Mix
Size of column X x Y
Main steel
First Floor ( centre of first
floor to centre of second Ties near slab
floor )
Ties in central height
Mix
Size of column X x Y
Main steel
Ground Floor ( centre of
ground floor to centre of first Ties near slab
floor )
Ties in central height
Mix
Size of column X x Y
Main steel
Basement Floor ( foundation Ties near slab
to centre of ground floor )
Ties in central height
Mix
DRAWING OF COLUMN

H/4

H
H/2
H/4
COLUMN SCHEDULE
C1,C6,C19,C24 C2,C5,C20,C23 NOTE : -
230 x 500 230 x 500 Clear cover - 40 mm
6-12 Ø 6-12 Ø
Lap shall be provided in central half length of the column
8 Ø @ 75 c/c 8 Ø @ 75 c/c and not more than 50 % of the reinforcement shall be
lapped at a given cross-section.
Lap shall be provided in central half length of the column
and not more than 50 % of the reinforcement shall be
lapped at a given cross-section.
8 Ø @ 150 c/c 8 Ø @ 150 c/c
M 20 M 20 Lap length - 45 Ø for mild steel , 47 Ø for HYSD bars.
230 x 500 230 x 500 minimum diameter of Main bars shall be 12 mm
6-12 Ø 6-12 Ø minimum diameter of Tie shall be 8 mm
8 Ø @ 75 c/c 8 Ø @ 75 c/c
8 Ø @ 150 c/c 8 Ø @ 150 c/c
M 20 M 20
230 x 500 230 x 500
4-16 Ø + 2-12 Ø 6-16 Ø
8 Ø @ 75 c/c 8 Ø @ 75 c/c
8 Ø @ 150 c/c 8 Ø @ 150 c/c
M 20 M 20
230 x 500 230 x 600
6-16 Ø 8-16 Ø
8 Ø @ 75 c/c 8 Ø @ 75 c/c
8 Ø @ 150 c/c 8 Ø @ 150 c/c
M 20 M 20
230 x 500 230 x 600
6-16 Ø 8-16 Ø
8 Ø @ 75 c/c 8 Ø @ 75 c/c
8 Ø @ 150 c/c 8 Ø @ 150 c/c
M 20 M 20
DRAWING OF COLUMN
Ground Level
FOOTING SCHEDULE
Footing Size of footing B x L Overall depth
mark depth at edge
B L
F1 1500 1800 500 230
F2
F3
F4
F5 THIS IS COMBINED FOOTING - REFER TO DRAWING NO.2
DRAWING OF FOOTING

75 mm

150 mm

b B
150 mm

150 mm
FOOTING SCHEDULE
Steel parallel to
Size of bed block b x l
Shorter side Longer side Column nos. NOTE : -
Dia. no. Dia. no. b l thickness Clear cover - 50 mm
10 13 10 11 1800 2100 150 C1,C6,C24 Reinforcement prallel to longer side are placed in
first layer

S IS COMBINED FOOTING - REFER TO DRAWING NO.2 C7 - C8


DRAWING OF FOOTING

Ground Level

Overall depth
depth at edge
150 mm

reinforcement parallel to
longer side ( First layer )
reinforcement parallel to
shorter side ( second layer )

L
150 mm

l
SLAB SCHEDULE
Reinforcement provided
Thickness in parallel to shorter side parallel to longer side
Slab mark Remark
mm straight ( or full ) Bent ( or curtailed ) straight ( or full ) Bent ( or curtailed )
DIA. SPACING DIA. SPACING DIA. SPACING DIA. SPACING
S1 120 10 Ø 300 10 Ø 300 6Ø 150 - - Straight slab
S2 130 12 Ø 350 10 Ø 350 8Ø 170 - - Sloping slab
S3 110 10 Ø 150 - - 6Ø 140 - - Sunk slab

NOTE : -
Clear cover - 15 mm
Chairs of approved types shall be used to support the slab steel where
necessary.At least one chair shall be used to each 1.5 m2 of floor area.
Chairs of approved types shall be used to support the slab steel where
necessary.At least one chair shall be used to each 1.5 m2 of floor area.
BEAM SCHEDULE
reinforcement provided
Stirrups
Bottom Bar Top Bar
Beam size B x D in straight ( or full straight ( or full
Extra at centre extra at support left support Centre right support Remark
mark mm ) )
length in cut off at length in c/c c/c c/c
Dia. No. Dia. No. Dia. No. Dia. No. Dia. Dia. Dia.
m in m m Spacing Spacing Spacing
B1 230 450 12 Ø 2 16 Ø 3 10 Ø 2 16 Ø 2 6Ø 130 6Ø 250 6Ø 130
B2 230 450 16 Ø 2 16 Ø 3 12 Ø 2 - - 8Ø 130 8Ø 250 8Ø 130
B3 230 450 14 Ø 2 - - 10 Ø 2 16 Ø 3 6Ø 130 6Ø 250 6Ø 130
B4 230 450 12 Ø 2 - - 12 Ø 2 - - 8Ø 150 8Ø 300 8Ø 150
B5 230 450 16 Ø 2 - - 12 Ø 2 16 Ø 1 8Ø 150 8Ø 300 8Ø 150