Professional Documents
Culture Documents
IDRONAUT Products
IDRONAUT Products
IDRONAUT Products
IDRONAUT Srl
Via Monte Amiata, 10 I-20861 Brugherio (MB) ITALY
Tel: +39 039 879656 Fax: +39 039 883382
e-mail: idronaut@idronaut.it web: http://www.idronaut.it
Copyright 1982-2013 © Idronaut Srl
IDRONAUT products
CTDs
Multi-parameter probes
Sensors
Software
Deck units
Battery packs
Special products
OCEAN SEVEN
303Plus
HighTempProbe
OCEAN SEVEN
OCEAN SEVEN OCEAN SEVEN 303
OCEAN SEVEN
101 302 304Plus
OCEAN SEVEN
307
OCEAN SEVEN
304
OCEAN SEVEN
308
OCEAN SEVEN
306
OCEAN SEVEN OCEAN SEVEN
305 EA/89
OCEAN SEVEN
305Plus
1982 2012
Integrated rechargeable NiMH battery pack and 512MByte Flash data memory
Windows real-time data acquisition and post-processing software available
POM (1500 dbar) and titanium housing (7000 dbar) available
High quality pH, O2 and ORP sensors for 7000 dbar depth
Real-Time data acquisition and self-recording capability, 7000 dbar depth
20, 30 and 40Hz sampling rate, user selectable
Interfaces for non IDRONAUT sensors available upon request
Windows real-time data acquisition and post-processing software
Titanium housing
High quality temperature, pressure, pH, O2 and ORP sensors, for 4000
dbar depth
Special version for 90°C or even more
OEM version available for integration in geothecnical investigation tools
ISEs (Ion Selective Electrodes) available upon request
8Hz, Real-Time data acquistion 4000 dbar depth
TWO ACCURATE TEMPERATURE SENSORS - Each sensor features a fast Pt100 platinum resistance
thermometer with negligible self-heating effect. The main thermometer (time constant 50ms) is located inside
the measuring flow-through cell and the optional remote one can be up to 5 or 15 meter distance.
FLOW CONDUCTIVITY SENSOR - Features a large diameter, seven-ring quartz cell, which does not require
platinum black deposition and which can be cleaned without recalibrating.
OCEAN SEVEN 3xx CTDs
pH GLASS SENSOR and SOLID GEL REFERENCE ELECTRODE - Low impedance glass membrane pH
electrode in conjunction with a ceramic junction-less gel reference electrode.
OPTICAL SENSOR INTERFACE (external installation) - The system can interface a remote Fluorometer /
Turbidity meter installed in an additional measuring flow-through cell.
The OCEAN SEVEN 306 pH and redox probe is provided with analogue output 0..5V and allows the in situ
determination of pH and redox (ORP - Oxidation Reduction Potential) in natural waters as oceans, lakes, rivers
and estuaries, at depths down to 600 bar. The OCEAN SEVEN 306 pH and redox combined probe, is
specifically designed to simplify the integration in CTD probe.
Specification
OCEAN SEVEN 3xx CTDs
(*) The pH electronic range is user customizable to: 0..14 pH, 2..12 or 3..11(default).
(**) An offset of +2500mV shift the redox sensor output. Therefore the redox sensor output is +1500 mV to +3500 mV.
Conductivity
Temperature
Combined pressure and temperature
High precision 0.01% pressure
43mm AISI-316, 48mm Titanium, 100mm POM, 75mm POM, 89mm Titanium
wire)
Mounting Through 12 mm hole with two O-ring seals (Parker 2-12)
Cell dimensions inner diameter 8mm, length 45mm, weight 65 gr.
Body Black plastic and titanium
Pressure compensation Silicon oil
Turbidity Meter
Range 25, 125, 500,>750FTU .
Output Time Constant 0.1 sec
Sensing Distance < 5 cm (approx.)
Linearity < 2% deviation 0-750 FTU.
Temperature Coefficient < 0.05% / °C
Single&Three channel fluorometer
OCEAN SEVEN 3xx CTDs – Sensors
Portable Telemetry Deck Unit: Low Voltage (30/60 VDC) left, High Voltage portable (220VDC) right
Compact instrument designed for the metrology laboratory to perform calibration of oceanographic
CTDs. Interfaces standard 100Ω SPRT and a large size IDRONAUT conductivity cell.
Optionally it can be equipped with two temperature and two conductivity cells.
OCEAN SEVEN 3xx CTDs – CT Calibration
The Remote Depth Readout displays the OCEAN SEVEN 3xx CTD real-time pressure data, by
means of a LCD, housed in a rugged waterproof container suitable for mounting at the winch
operator’s position. The Remote Depth Readout display is connected to the personal computer
running the REDAS-5 program.
OCEAN SEVEN 3xx - Accessories
Features:
RS232C interface.
Supported by the IDRONAUT REDAS-5 real-time data acquisition software.
AC/DC 110-240 VAC 40-60Hz wall mounted power supply.
4 lines x 20 characters back lighted LCD display.
The module can be operated with cables up to 100 m long.
Plastic ABS container (UL-94V 0) ; dimensions : 200.x 110 x 60 mm ; weight: 0.5 Kg
Lightweight motorized winch specifically designed for the OCEAN SEVEN 3xx Multi-
parameter probes. The winch is complete with a safety friction clutch, a push button
for left and right rotation with slider and a 5-pole high quality slip-ring to allow
continue communication with the OCEAN SEVEN 3xx probes while rotating.
OCEAN SEVEN 3xx - Accessories
Characteristics:
Power supply 12 VDC
Run 1.5 A/h
Max 7.0 A/h
Torque 1,5Nm
Idle speed 42 rpm
Winding speed 16..24 m/min
Weight 10Kg (without cable)
Height 400 mm
Footprint 320 x 340 mm
Max. payload 15Kg
.
Self recording
RS232C Interface
RS485/422 Interface
OCEAN SEVEN 3xx CONFIGURATION CHART
IDRONAUT Telemetry
BulkHead sensors
Pressure: Accuracy (0.05%)
Accuracy (0.01%)
Conductivity
Fresh water accuracy (uS/cm) 5 5 10 10 10 5
Salt water accuracy (mS/cm) 0.005 0.003 0.007 0.007 0.007 0.005
Dissolved Oxygen
pH
Redox (ORP)
pCO2 (2)
Nitrate (2)
Ammonia (2)
H2S (2)
Turbidity (3)
Fluorometer (3)
PAR
Transmissometer
OCEAN SEVEN 3xx CONFIGURATION CHART
Altimeter
Submersible pump
Antifouling system
Telemetry
MkPlus Deck Unit (QAM)
Inductive (DPSK)
Housing
100 mm POM Plastic (max 150 bar)
ITERM
OCEAN SEVEN 3xx CONFIGURATION CHART
uREDAS
MULTIPLEX
Accessories Options
ViP system interface
Portable Reader
(1) CTD sampling rate, diiferent combination of sensor may affect the sampling rate
(2) Only applicable to fresh water
(3) SPECIAL OEM BULKHE
(4) Chelsea, Seapoint, Wetlabs, Turner design optical sensors having analog (0..5V)or digital (RS232) interfaces can
be used.
Analytical specifications:
Measurable elements or compounds: cu(iii), pb(ii), cd(ii), zn(ii), mn(ii), fe(ii)
Extension to other elements or compounds is possible.
Lowest detection limits: 50 pm (10 ppt) (15 minutes deposition time)
Measurement range 0.2 nm to 500 nm ( 5 minutes deposition time)
40 ppt to 1000 ppt (5 minutes deposition time