Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

ENGLISH UN-RP

terminal block L (black) relay actuator


INSTALLATION INSTRUCTIONS FOR ELECTRICIANS

FUNCTION AND INTENDED USE ERROR STATUSES:

Subject to technical changes. Latest information can be found on our website. www.onesmartcontrol.com
The black (optionally light, shade, climate group ...) Terminal block L is provided for connecting 1 x flash - 1 x pause: . . . . . . . . overtemperature
large lamp loads or large electrical loads. Connected loads can be controlled over the 230 4 x flash - 1 x pause: . . . . . . . . overload
V wiring via ONE commands. A push-button input is available on the terminal block that 5 x flash - 1 x pause: . . . . . . . . overload & overtemperature
allows the output to be switched without using ONE. For further user information about
ONE, e.g. how to select light scenes, operate from multiple locations, activate timer controls LOCAL OPERATION:
etc., please refer to the ONE user manual: www.onesmartcontrol.com/support A push-button input (1) is available on the terminal block. Pressing the
LED with a screwdriver can also operate the push-button input.
MORTAL DANGER!
Touching live electric house wiring (230 V AC) may lead to death or severe Short tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . switch ON/OFF
burns. Disconnect all power before installing this device and check for the Keep pressed when switched OFF . . . . . . . . . . . . . . . . . . . . . . . after 1s: Turn room colour group OFF
absence of voltage. Prevent third parties from turning ON the voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Only with yellow setting:
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . after 2s: room standby
IMPORTANT INFORMATION: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . after 3s: room Deep Off
Only qualified personnel are authorised to install and commission the Double tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . request scene 2
module. Specific national regulations must be followed. The device Triple tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . request scene 3
may only be operated in dry rooms and must not be used directly or Quadruple tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . request scene 4
indirectly for health or life-saving purposes or for purposes where
a device failure could endanger people, animals or property. LOCAL PARAMETER CONFIGURATION:
Parameter 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . output (switch, economy, wipe operation)
INSTALLATION: Parameter 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . colour group
Use the mounting box (switch box or ceiling outlet box) appropriate for the power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (yellow, gray, blue, cyan, magenta, black)
18

circuit. Deep installation boxes are recommended for new projects. Optionally, the Parameter 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . push-button function
terminal block can be installed directly in lamps. Permissible ambient temperature and . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . (device push-button / zone switch /
44 48,5
the manufacturer's device-specific installation instructions must be observed. After the . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . room switch)
electrical connection has been made and the power switched ON, the terminal block is
automatically registered with the ONE meter in the power distribution panel. The device Prior to changing these parameters, always refer to the additional information
DIMMABLE LAMPS: is then immediately ready for operation and can be controlled via ONE commands. in the ONE Installation Guide: www.onesmartcontrol.com/support
D = 5,0
Dimmable lamps
can only be switched MODES OF OPERATION: LOCAL PARAMETER CONFIGURATION:
with this product, The Terminal block UN-RP has three operational modes: Switch: a lamp can be switched Short-short-long until output / LED flashes . . . . . . . . . . . . . . activation
but not dimmed. ON / OFF over the customary scene requests Furthermore, the effect of the push-button Double tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . switch between parameters
input can be changed. Economy - output switches only by scenes "Leave", "Sleep", Short tap . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . change the selected parameters
(mm)
"Deep Off", for example, switching off devices with standby loads in your absence. After 30 seconds without activity . . . . . . . . . . . . . . . . . . . . . . . . automatic abort without saving
Wipe - device briefly switches on/off by "OFF" and "Standby" scenes, for example, to Keep pressed (about 3 seconds) while activating . . . . . . . . save and exit
place TV / coffee machine into standby mode. In addition, group membership (colour)
of the terminal block can be changed. The operating mode can be changed by the PARAMETER DETAILS:
PE ONE server's installation software as well as manually by using the push-button. Parameter 1: . . . . . . . . . . . . . . . Switch: LED flashes, wipe: LED ON, flash briefly OFF;
N . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Economy: LED dims OFF
L FUNCTION MAPPING AS DELIVERED FROM THE FACTORY: Parameter 2: . . . . . . . . . . . . . . . LED changes colour, display order:
B 16 A current colour group . . . . . . . yellow (light) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Rainbow ... selected colour ... rainbow ... selected colour ...
230 VAC SmartOne
Output . . . . . . . . . . . . . . . . . . . . . . switch operation Parameter 3 . . . . . . . . . . . . . . . . Device push-button: LED glows, room switch: LED flashes 5x;
Push-button input . . . . . . . . . . device push-button . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . zone switch 1 (or 2, 3, 4): LED flashes 1x (or 2x, 3x, 4x)
230 V
POWER FAILURE: GUARANTEE:
The terminal block saves the output status if it has been unchanged for at least ONE guarantees fault-free operation of this device in accordance with the specifications
5 seconds. After a power failure, the saved output status is restored. for 24 months from delivery by ONE. Opening the device, tampering with the
8 mm 0.75...1.5 mm² device or incorrect installation / configuration invalidates the guarantee.
Lamp OVERLOAD:
230 V The terminal block detects overloads and switches OFF the output. A reset TECHNICAL DATA:
is preformed the next time a scene is selected (command via ONE or push- Switching principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . electromechanic, relay DE2a-L2-24V
UN-RP button operation), provided the overload no longer exists. Resistive load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 1400 W (6A)
Inductive / capacitative load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ≤ 700 W (3A)*
L1‘
OVERTEMPERATURE: Rated input voltage / frequency . . . . . . . . . . . . . . . . . . . . . . . . . 230 V AC / 50 Hz
L 1 N L1'
The output is switched OFF if a thermal overload exists for a long period of Power consumption . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.4 W
max. K1 Protection class (dry rooms) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . IP20 EN 60529
time. It is automatically switched ON after the cool-down phase.
0.5 Nm Permissible ambient temperature (operation) . . . . . . . . . . . -20 °C ... +40 °C
L STATUS INDICATOR (LED): Permissible ambient humidity (operation) . . . . . . . . . . . . . . . < 80% relative humidity, non-condensing

Doc. No. DA-021-05_UN-RP


max. 3 mm LED+push-button Status: The LED provides feedback on the last action performed on the device's Maximum cable length of local switch . . . . . . . . . . . . . . . . . . . < 10 m*
output. Scene active = LED 100% ON, scene inactive = LED strongly dimmed. The
LED flashes during scene changes. When setting the room scene (programming
mode) the LED flashes 2 times when the terminal block is selected.
Deep Off: The LED is OFF in "Deep Off" room status.
EN 60669 Registration: The LED flashes quickly while registering with a ONE system.
EN 50428

* Nominal operation. Check the starting current load.