10-77 A cogeneration plant modified with regeneration is to generate power and process heat. The mass flow rate of steam
through the boiler for a net power output of 25 MW is to be determined.
Assumptions 1 Steady operating conditions exist. 2 Kinetic and potential energy changes are negligible.
Analysis From the steam tables (Tables A-4, A-5, and A-6),
6
h1 h f @ 10 kPa 191.81 kJ/kg
Turbine
v1 v f @ 10 kPa 0.00101 m 3 /kg Boiler
7
wpI,in v 1 P2 P1 8
3
1 kJ
0.00101 m /kg 1600 10 kPa
1 kPa m 3
Process
1.61 kJ/kg 5
heater
9 Condense
h2 h1 wpI,in 191.81 1.61 193.41 kJ/kg r
h3 h4 h9 h f @ 1.6 MPa 858.44 kJ/kg 4 3 1
PI
v4 v f @ 1.6 MPa 0.001159 m /kg 3 PII fwh
2
wpII,in v 4 P5 P4
T
1 kJ
0.001159 m 3 /kg 9000 400 kPa
1 kPa m 3
6
s8 s f 6.2876 0.6492
P8 10 kPa x8 0.7518
s fg 7.4996
s8 s 6 h h x h 191.81 0.75182392.1 1990.2 kJ/kg
8 f 8 fg
Thus,
W net 25,000 kJ/s
m 29.1 kg/s
wnet 860.1 kJ/kg