Professional Documents
Culture Documents
Slab PDF
Slab PDF
lx x
½ Column strip
Middle strip
ly
½ Column strip
½ Column strip Middle strip ½ Column strip
Slab definition
Slab thickness; h = 5.00 in
Materials
Specified compressive strength of concrete; f’c = 3000 psi
Loads
Total factored ultimate load on slab; wu = 150.000 psf
Clear span y – dir – cl. 8.10.3.2.1; lny = max(0.65 ly, (ly – bw/2 – bw/2)) = 14.000 ft
Moment distribution for interior panel – cl. 8.10.4.1; M’ux = 0.65 × Mox = 49.771 kip_ft
ly / lx = 0.86
fx × ly / lx = 0.79
fx_pos = 0.75
Total column strip design moments; M’x_col_stp = fx_neg × M’ux = 39.013 kip_ft
Total middle strip design moments; M’x_mid_stp = (1 - fx_neg) × M’ux = 10.758 kip_ft
kip_ft/ft
Moment distribution for interior panel – cl. 8.10.4.1; M’uy = 0.65 × Moy = 41.803 kip_ft
lx / ly = 1.17
fy × lx / ly = 0.92
fy_pos = 0.69
Total column strip design moment; M’y_col_stp = fy_neg × M’uy = 29.426 kip_ft
Total middle strip design moment; M’y_mid_stp = (1 - fy_neg) × M’uy = 12.377 kip_ft
kip_ft/ft
Reinforcement calculations
Stress block depth factor; 1 = 0.85
=0.00246
Outer compression steel not required
Area of tension steel required; A’sx_req_mid = ’reqx_mid × d’x_mid = 0.120 in2/ft
=0.00151
Outer compression steel not required
Area of tension steel required; Asx_req_mid = reqx_mid × dx_mid = 0.073 in2/ft
=0.00258
Outer compression steel not required
Area of tension steel required; A’sy_req_mid = ’reqy_mid × d’y_mid = 0.114 in2/ft
=0.00143
Outer compression steel not required
Area of tension steel required; Asy_req_mid = reqy_mid × dy_mid = 0.063 in2/ft
Design shear strength of slab; Vc = 0.75 × 2 × (f’c × 1 psi) × 1 ft × dy_mid = 3.636
kips
PASS - One-way shear capacity
Check for clear cover (ACI 318 cl. 20.6.1.3)
Permissible min nominal cover to all reinforcement; cmin = 0.75 in
lx x
½ Column strip
A'sy_col
Asx_col A'sx_col
Asy_mid
Middle strip
ly
Asx_mid A'sx_mid
Asy_col
½ Column strip
A'sy_mid