Engine hunting
Symptom
Engine was hunting until shutdown when operating hour is about 30 minutes.
History
For this problem, they changed supply pump and injectors. (was not OK).
We tested the machine, engine was hunting and shut down after testing about 30 minutes. Two errors
appear 1080-2 and 10011-2. Rail pressure sensor supply low voltage and barometric pressure sensor low
voltage. We check wiring, engine wire harness is abnormal(shield ground wire and power supply wire is
short circuit). We repaired it and test run was OK.
Action
Parts
Part number responsible Part number replaced
Parts no. Description Qty Parts no. Description Qty
Picture
Remark
Disclaimer:
This Technical Service Bulletin cannot guarantee the accuracy of all information.
Please confirm the information with an appropriate manual.
Win Progress Co., Ltd.
TECHNICAL SERVICE BULLETIN
Manufacturer Product Line Engine Model Page
Hitachi EXCAVATOR 6WG1 2 of 2
Component Group Model Series Date
ZX 670LCH-3F 20607 25.7.2011